www.aasinternational.nl
H4 34L-16R
Runway and Taxiway Guidance Signs
Technical Specifications
www.aasinternational.nl
Table of content
1.Introduction ..................................................................................... 3
2.Appliance ......................................................................................... 3
3.Compliancewithcurrentdirectives ................................................. 3
4.Characteristics ................................................................................. 3
5.Signspecifications............................................................................ 4
6.Strengthandfrangibility .................................................................. 6
7.Photometryandcolor ..................................................................... 8
8.Powerunit ....................................................................................... 9
9.Maintenanceandspareparts ........................................................ 10
10.Options ........................................................................................ 11
DisclaimerReprinting, translation or reproduction in any form - whether in part or in full - requires the prior written permission of AAS International BV.
No rights can be derived from the information in this brochure. Product dimensions, specifications and configurations as presented in this brochure are subject to change without prior notice.
www.aasinternational.nl
1. Introduction
TheAllAboutSignsInternationalFLAT-Lightseries3isspeciallydesignedforrunwaysandtaxiwaysasinformation,directionandpositionindicatorinaccordancewiththeEASA,ICAOandFAAdirectives.ThisproductismadeinTheNetherlandsbyofficialpartnerVDLIndustrialModulesBV(www.vdlgroup.com).Thesignscanbepoweredbyconstantcurrentregulator,mainspowersystemorrenewableenergysourcelikesolarenergy.
2. Appliance
• RunwaySign• TaxiwayGuidanceSign• StandInformationSign
3. Compliance with current directives
• EASACS-ADR-DSN• ICAOAerodromeDesignandOperations,Annex14, Volume1,Appendix1-3
• ICAOAerodromeDesignandOperations,Annex14, Volume1,Appendix4
• ICAOAerodromeDesignManual,Part6,Frangibility• FAAAC150/5345-44• NATO–Stanag3316(RunwayDistanceMarkers)
4. Characteristics
• Powersupply:2.2–6.6AmultiplestepAGLcircuit,mainspowersystemorrenewablesource
• Operatingtemperature-40°/+55°C(Class1)• Lightweightaluminumcasing• 6mmPolycarbonatefrontpanelagainstdebrisandchunksofice• Galvanizedsteelpolesandfootplateswithfrangiblecoupling• StainlessSteelsafetycable• IP65protectionagainstmoistanddust• Nomaintenanceneeded,exceptforcleaningtheoutside
www.aasinternational.nl
5. Sign specifications
Runway Signs and Taxiway Guidance Signs
type # legend face face sign sign power consumption (W) # legs # legs height height length height length black legend white legend mode 2 mode 3 (mm) (mm) (mm) (mm) (mm) yellow background red background (322 kph) (483 kph)
FL09060 300 600 900 668 968 12 23 2 2FL12060 300 600 1200 668 1268 16 30 2 2FL15060 300 600 1500 668 1568 19 37 2 2FL18060 300 600 1800 668 1868 23 44 2 2FL21060 300 600 2100 668 2168 28 51 3 3FL24060 300 600 2400 668 2468 30 59 3 3FL27060 300 600 2700 668 2768 35 68 3 3FL30060 300 600 2932 668 3000 40 75 3 3
type # legend face face sign sign power consumption (W) # legs # legs height height length height length black legend white legend mode 2 mode 3 (mm) (mm) (mm) (mm) (mm) yellow background red background (322 kph) (483 kph)
FL09080 400 800 900 868 968 16 30 2 2FL12080 400 800 1200 868 1268 21 40 2 2FL15080 400 800 1500 868 1568 26 51 2 2FL18080 400 800 1800 868 1868 33 61 2 2FL21080 400 800 2100 868 2168 37 70 3 3FL24080 400 800 2400 868 2468 42 82 3 3FL27080 400 800 2700 868 2768 47 91 3 3FL30080 400 800 2932 868 3000 54 101 3 3
1800 (signface)
800
(sig
nfac
e)
C
C
D
E
SECTION C-C
*Numberoflegsdependsonlengthofthesignandmode(2or3).
www.aasinternational.nl
No Entry Signs
type # legend face face sign sign power # legs # legs height height length height length consumption mode 2 mode 3 (mm) (mm) (mm) (mm) (mm) (W) (322 kph) (483 kph)
FL09080 400 800 900 868 968 30 2 2
Footplate and frangible coupling.
www.aasinternational.nl
6. Strength and frangibility
Becauseofnewandmorepowerfulaircraftsthestrengthandfrangibilityofthesignhasbecomemoreimportantthanever.Itisachallengetodesignasign-conceptthatisstrongenoughtowithstandawindloadof483kphandisfrangiblewhenanobjectcollideswiththesign.Twocharacteristicsthatarecontradictoryanddemandarigorousapproach.
ThedesignhasbeensubjecttothoroughFEManalysisforthehighestload:mode3,windload483kph.TestedandcertifiedaccordingEASA/ICAOregulations.Andmoreover:thesignhassuccessfullyproveditsstrengthatseveralleadingairports.
Visualisation of wind load on the front panel.
Visualisation of wind load on the back side.
www.aasinternational.nl
Analysis of the frangible coupling.
The value of the discolouration is set to show all stress above the yield strength of the coupling
Detail of the
Displacement of the strut at full load.
www.aasinternational.nl
7. Photometry and color
photometricmeasurements averagevalue(cd/m2) requiredICAO(cd/m2)
yellow 252 >150red 37.6 >30white 332 >300
Chromaticcoordinates x y
yellow 0.510 0.485red 0.688 0.311white 0.363 0.345
0
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
White (day)
Black
White (night)
Yellow
Red
Y
X
www.aasinternational.nl
FORMAT REFERENCE NUMBER DRAWING NUMBER VERSION
SCALE PAGE 1 DATE 27-12-2017
288255PART
SUBJECT
Electric diagram TGS – Standard version – EE-PSU-04- without CCR-switch
SHORT DISCRIPTION
Electric diagram TGS (Taxiway Guidance Sign) and connection data terminal block X 1 - Standard version
AAS International bvBrandevoortse dreef 4
5707 DG Helmond
E
X1-2
-SEC
X1-1
-SEC
CON2
-AC
Inpu
tPC
B co
nnec
tor
CON1
-AC
Inpu
tPC
B co
nnec
tor
From CCR – 2.8A – 6.6ASecundary trafo
X1-3 X1-4
Current Loop (CCR), Primary
X1-5-LED + rd1-LED +2-LED -
AC Current Controlled Supply – EE-PSU-04
LED- module 2-1 | Down LED- module 2-X | Down
X1-7-LED - zw
PCB1
Current Loop (CCR), Primair
LED1 – Led- modules Taxiway Guidance Sign
LED2 – Led- modules Taxiway Guidance Sign
2.4A
Wag
o Te
rmin
al
221-
412
X1-9
-PE
Flex Ye/Gn-1
PRI1
PRI2PE
PE – Protective Earth – BC 4 mm²
Chassis TGS (Taxiway Guidance Sign)Case Power Supply TGS
Secundary cable / connectorPE – Protective Earth – BC 4 mm² Foot – Break link
Stra
nded
Bla
ck –
2.5
Stra
nded
Gre
y –
2.5
PE LED Aluminium profile
PE – Stranded Ye/Gn 2.5 mm² Outside Aluminium case (M5)
194971
PE LED Aluminium profile
PE – Stranded Ye/Gn 2.5 mm² Cover Aluminium case
Comments: Grounding of the light reflectors (1 x front and 2 x side reflector): conductive connect to the chassis
- without CCR-switch- 1x EE-PSU-04- 4x6 LED modules
LED- module 1-1 | Up
CON4PCB connector
1-LED +2-LED -
CON5PCB connector
CON7-CANBUSPCB connector
10 Dipswitches
LED- module 1-X | Up
Flex
Ye/
Gn-1
.5
X1-8-LED – zw
X1-6-LED + rd
Wag
o Te
rmin
al
221-
412
Flex Black 4–1.5
Flex Black 2–1.5
Flex Black 3–1.5
Flex Black 1–1.5
X1 – Terminal list
Conductor color Function terminal 1 Terminal 1 Function terminal 1 Conductor color Page
End terminalBlack SEC, From CCR 1 AC Input 1 – CON1 1Grey SEC, From CCR 2 AC Input 2 – CON2 1
34
Black 1 LED+ Up 5 LED+ CON4-1 Red 1Black 2 LED+ Down 6 LED+ CON5-1 Red 1
Yellow/Green PE LED- profile 9 PE Cover (Alu case) Yellow/Green 1End terminal
Discription
PCB connectorPCB connector
PCB connectorPCB connector
Black 3 LED- Up 7 LED- CON4-2 Black 1Black 4 LED- Down 8 LED- CON5-2 Black 1
PCB connectorPCB connector
View terminal block X 1
123456789
PSU-04 LED power unit
8. Power unit
Connectiondiagramwhenpoweredby2.2-6.6AAGLcircuit.
Power unit PSU-006INPUT CONSTANT CURRENT RANGE 2.8A ~ 6.6A
FREQUENCY RANGE 50Hz / 60HZ POWER FACTOR (Typ.) PF > 0.82 @ Input 2.8A & Output 1A
> 0.95 @ Input 6.6A & Output 1A OUTPUT DC VOLTAGE 17V ~ 25V
DC CURRENT 2 x 60mA ~ 1.600mA MAX. POWER DEFAULT 80W PROGRAMMING Dip-switches and Jumpers
ENVIROMENT WORKING TEMPERATURE -40 °C ~ +55°C HUMINITY 20 % ~ 95 % RH non-condensing IP RATE IP52
EMC EMISSION EN55022 IMMUNITY EN55024-4-2 ~ EN55024-4-6
www.aasinternational.nl
9. Maintenance and spare parts
TheAASInternationalsignsneednomaintenanceotherthancleaningtheoutsideofthesign.TheLEDstripshavealifespanofapproximately10years*1.ThePSU-04driverhasalifespanofapproximately5years*1.Despitethelonglifeexpectancyofallpartsitisadvisedtohavesomepartsonstockincaseofcalamities.
part priority*2
LEDsegment 1Pre-mountedICLdriver 1Programmingdevice 1Frangiblecoupling 1Footplate 1Supportpole 2Legendpanel 2Bird-pinsandbrackets 2
*1 Depending on local environmental circumstances and use.*2 The priority always depends on the airports operation policy.
www.aasinternational.nl
10. Options
description standard optional
6mmPolycarbonatelegendpanel •AluminumIP65housing,RALcolorpowdercoated •AluminumIP65housing,RALcolorpowdercoatedwithseaareaprotection •Closingfrontpanelbysecuredlatches,stainlesssteel304 •Galvanizedsteelpoles •Galvanizedsteelfootplates •StainlessSteelsafetycable •ExtraStainlessSteelsafetycable •Anti-birdpins •Powerswitch •PoweredbyAGLcircuit-lineardimmable:variableoutputaccordinginput •PoweredbyAGLcircuit-non-dimmable:constantlightoutput •Poweredbymainssystem230Vac •Poweredbyrenewableenergysource •
Anti-bird pins
www.aasinternational.nl
AAS International BVwww.aasinternational.nl
Other products:•VariableGuidanceSigns•Non-illuminatedGuidanceSigns