Robert L Renshaw, Jr.

Robert L Renshaw, Jr.

Campus Layout

Project Specifications

Design a wiring plan and Networking/Internetworking solution for an Ethernet

extended star topology LAN that uses both fiber-optic and CAT 5 UTP cabling.

Project Specifications

Design a wiring plan and Networking/Internetworking solution for an Ethernet

extended star topology LAN that uses both fiber-optic and CAT 5 UTP cabling.

Robert L Renshaw, Jr.

Robert L Renshaw, Jr.

Totals

MDF24 Devices12 Rooms

IDF M122 Devices11 Rooms

Total46 Devices23 Rooms

Totals

MDF24 Devices12 Rooms

IDF M122 Devices11 Rooms

Total46 Devices23 Rooms

POP

MDF

IDF M1

Main Building First Floor Catchment Areas

Robert L Renshaw, Jr.

IDF M2A

IDF M2B

TOTALS

IDF M2A20 Devices10 Rooms

IDF M2B20 Devices10 Rooms

Total40 Devices20 Rooms

TOTALS

IDF M2A20 Devices10 Rooms

IDF M2B20 Devices10 Rooms

Total40 Devices20 Rooms

Main Building Second FloorCatchment Areas

Robert L Renshaw, Jr.

TOTALS

IDF E130 Devices

Total30 Devices15 Rooms

TOTALS

IDF E130 Devices

Total30 Devices15 Rooms

IDF E1

East Building First FloorCatchment Area

Robert L Renshaw, Jr.

TOTALS

IDF E230 Devices15 Rooms

TOTALS

IDF E230 Devices15 Rooms

IDF E2

East Building Second FloorCatchment Area

Robert L Renshaw, Jr.

TOTALS

IDF W130 Devices15 Rooms

TOTALS

IDF W130 Devices15 Rooms

IDF W1

West Building First FloorCatchment Area

Robert L Renshaw, Jr.

TOTALS

IDF W228 Devices14 Rooms

TOTALS

IDF W228 Devices14 Rooms

IDF W2

West Building Second FloorCatchment Area

Project Totals

Main Building

First Floor - 23 Rooms, 46 Computing Devices

Second Floor - 20 Rooms, 40 Computing Devices

East Building

First Floor - 15 Rooms, 30 Computing Devices

Second Floor - 15 Rooms, 30 Computing Devices

West Building

First Floor - 15 Rooms, 30 Computing Devices

Second Floor - 14 Rooms, 28 Computing Devices

Total

102 Rooms

204 Computing devices

Project Totals

Main Building

First Floor - 23 Rooms, 46 Computing Devices

Second Floor - 20 Rooms, 40 Computing Devices

East Building

First Floor - 15 Rooms, 30 Computing Devices

Second Floor - 15 Rooms, 30 Computing Devices

West Building

First Floor - 15 Rooms, 30 Computing Devices

Second Floor - 14 Rooms, 28 Computing Devices

Total

102 Rooms

204 Computing devices

Robert L Renshaw, Jr.

Tying it all

TOGETHERTOGETHER

Robert L Renshaw, Jr.

Main Building First FloorCut-Sheet Diagram

MDF

IDF M1

Robert L Renshaw, Jr.

POP

MDF Wire Map

Robert L Renshaw, Jr.

IDF-M1 Wire Map

Robert L Renshaw, Jr.

Main Building Second FloorCut-Sheet Diagram

IDF M2B

IDF M2A

Robert L Renshaw, Jr.

IDF-M2A Wire Map

Robert L Renshaw, Jr.

IDF-M2B Wire Map

Robert L Renshaw, Jr.

East Building First FloorCut-Sheet Diagram

IDF E1

Robert L Renshaw, Jr.

IDF-E1 Wire Map

Robert L Renshaw, Jr.

East Building Second FloorCut-Sheet Diagram

IDF E2

Robert L Renshaw, Jr.

IDF-E2 Wire Map

Robert L Renshaw, Jr.

West Building First FloorCut-Sheet Diagram

IDF W1

Robert L Renshaw, Jr.

IDF-W1 Wire Map

Robert L Renshaw, Jr.

West Building Second FloorCut-Sheet Diagram

IDF W2

Robert L Renshaw, Jr.

IDF-W2 Wire Map

Robert L Renshaw, Jr.

West Building East Building

Fiber-Optic Backbone Topology

MDFMDF

POPPOP

IDF E2

IDF E2

IDF W2

IDF W2

IDF W1

IDF W1

IDF M1

IDF M1

IDF M2A

IDF M2A

IDF M2B

IDF M2B

IDF E1

IDF E1

Main Building

Robert L Renshaw, Jr.

MDF Cut-sheetSW-MDFWorkgroup

SwitchToSW-M1

inIDF-M1

ToSW-M1

inIDF-M1

ToSW-M2A

inIDF-M2A

ToSW-M2A

inIDF-M2A

ToSW-E1 in IDF-E1,SW-W1 in IDF-W1

&POPvia

Fiber Distribution Panel located in the

POP

ToSW-E1 in IDF-E1,SW-W1 in IDF-W1

&POPvia

Fiber Distribution Panel located in the

POP

RTR-MDFRouter

Robert L Renshaw, Jr.

IDF-M1 Cut-sheet

SW-M1Workgroup

Switch

ToSW-MDF

inMDF

ToSW-MDF

inMDF

Robert L Renshaw, Jr.

ToSW-M2B

inIDF-M2B

ToSW-M2B

inIDF-M2B

ToRTR-MDF

inMDF

ToRTR-MDF

inMDF

IDF-M2A Cut-sheet

SW-M2AWorkgroup

Switch

Robert L Renshaw, Jr.

IDF-M2B Cut-sheet

SW-M2BWorkgroup

Switch

ToSW-M2A

inIDF-M2A

ToSW-M2A

inIDF-M2A

Robert L Renshaw, Jr.

ToSW-E2(W2)

inIDF-E2(W2)

ToSW-E2(W2)

inIDF-E2(W2)

ToFiber

DistributionPanel

inPOP

ToFiber

DistributionPanel

inPOP

IDF-E1 & IDF-W1Cut-sheet

SW-E1(W1)Workgroup

Switch

Robert L Renshaw, Jr.

IDF-E2 & IDF-W2Cut-sheet

SW-E2(W2)Workgroup

Switch

ToSW-E1(W1)

inIDF-E1(W1)

ToSW-E1(W1)

inIDF-E1(W1)

Robert L Renshaw, Jr.

ToSW-E1

inIDF-E1

ToSW-E1

inIDF-E1

ToSW-W1

inIDF-W1

ToSW-W1

inIDF-W1

ToRTR-MDF

inMDF

ToRTR-MDF

inMDF

POP Cut-sheet

Fiber Distribution Panel

Fiber Distribution Panel

Robert L Renshaw, Jr.

Backbone Cabling Wire Map

Robert L Renshaw, Jr.

Equipment &

Pricing

Equipment &

Pricing

Robert L Renshaw, Jr.

MDF Equipment Rack

top related