road lighting simulation
Post on 03-Feb-2022
4 Views
Preview:
TRANSCRIPT
Road Lighting Simulation
Partner for Contact: Order No.: Company: Customer No.:
Date: 16.03.2018Operator:
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Table of contents
Road Lighting SimulationProject Cover 1Table of contents 2Luminaire parts list 3Exterior Scene 1
Planning data 4Luminaires (layout plan) 5Luminaires (coordinates list) 63D Rendering 7False Color Rendering 8Exterior Surfaces
Calculation Grid Of RoadSummary 9Value Chart (E, Perpendicular) 10Table (E, Perpendicular) 11
Page 2
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Road Lighting Simulation / Luminaire parts list
4 Pieces HB02-150 5000K Ra80 90140DEG H28403Article No.: Luminous flux (Luminaire): 20154 lmLuminous flux (Lamps): 20154 lmLuminaire Wattage: 151.3 WLuminaire classification according to CIE: 100CIE flux code: 45 83 98 100 100Fitting: 1 x 5000K Ra80 (Correction Factor 1.000).
See our luminaire catalog for an image of
the luminaire.
Page 3
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Planning data
Light loss factor: 0.70, ULR (Upward Light Ratio): 0.0% Scale 1:1259
Luminaire Parts List
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
1 4HB02-150 5000K Ra80 90140DEG H28403 (1.000)
20154 20154 151.3
Total: 80615 Total: 80616 605.2
Page 4
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Luminaires (layout plan)
Scale 1 : 1259
Luminaire Parts List
No. Pieces Designation
1 4 HB02-150 5000K Ra80 90140DEG H28403
Page 5
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Luminaires (coordinates list)
HB02-150 5000K Ra80 90140DEG H2840320154 lm, 151.3 W, 1 x 1 x 5000K Ra80 (Correction Factor 1.000).
No. Position [m] Rotation [°]X Y Z X Y Z
1 40.000 25.000 8.000 0.0 0.0 0.0
2 80.000 25.000 8.000 0.0 0.0 0.0
3 120.000 25.000 8.000 0.0 0.0 0.0
4 160.000 25.000 8.000 0.0 0.0 0.0
Page 6
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / 3D Rendering
Page 7
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / False Color Rendering
Page 8
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Calculation Grid Of Road / Summary
Scale 1 : 1259Position: (60.028 m, 25.005 m, 0.000 m)Size: (40.000 m, 15.000 m)Rotation: (0.0°, 0.0°, 0.0°)Type: Normal, Grid: 15 x 5 Points
Results overview
Eh m/Em = Relationship between middle horizontal and vertical illuminance, H = Measuring Height
No. Type Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax Eh m/Em H [m] Camera
1 perpendicular 20 3.65 59 0.18 0.06 / 0.000 /
Page 9
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Calculation Grid Of Road / Value Chart (E, Perpendicular)
Values in Lux, Scale 1 : 286
Position of surface in external scene:Marked point: (40.028 m, 17.505 m, 0.000 m)
Grid: 15 x 5 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
20 3.65 59 0.18 0.06
Page 10
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Calculation Grid Of Road / Table (E, Perpendicular)
Position of surface in external scene:Marked point: (40.028 m, 17.505 m, 0.000 m)
13.500 25 23 19 14 9.64 6.43 4.32 3.70 4.35 6.50
10.500 51 41 31 21 14 9.51 6.07 5.04 6.12 9.60
7.500 59 44 33 22 16 10 6.57 5.41 6.63 10
4.500 51 41 31 21 15 9.46 6.01 4.98 6.06 9.55
1.500 25 23 19 14 9.85 6.46 4.28 3.65 4.31 6.53
m 1.333 4.000 6.667 9.333 12.000 14.667 17.333 20.000 22.667 25.333
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 15 x 5 Points
Eav
[lx] Emin
[lx] Emax
[lx] u0 Emin
/ Emax
20 3.65 59 0.18 0.06
Page 11
Road Lighting Simulation
16.03.2018
OperatorTelephone
Faxe-Mail
Exterior Scene 1 / Calculation Grid Of Road / Table (E, Perpendicular)
Position of surface in external scene:Marked point: (40.028 m, 17.505 m, 0.000 m)
13.500 9.72 14 19 23 25
10.500 15 21 31 41 51
7.500 16 23 33 44 59
4.500 15 21 31 42 51
1.500 9.94 14 19 23 25
m 28.000 30.667 33.333 36.000 38.667
Attention: The coordinates refer to the image above. Values in Lux.
Grid: 15 x 5 Points
Eav
[lx] Emin
[lx] Emax
[lx] u0 Emin
/ Emax
20 3.65 59 0.18 0.06
Page 12
top related