promax 3d promax 3d – cone beam volumetric tomography all in one – 3d – panoramic –...
Post on 31-Mar-2015
252 Views
Preview:
TRANSCRIPT
ProMax 3D
• ProMax 3D – Cone Beam Volumetric Tomography• all in one
– 3D – Panoramic– Tomography– Cephalometry
• Simple and easy patient positioning• Robotic SCARA movement,
adjustable volume place • Selectable image volume size• Latest flat panel technology• Pulsed X-ray generator
all in one
Upgradeable to all Planmeca ProMax units
New diagnostic possibilities – in dental office
Planmeca ProMax
Easy modality change
Simple and easy patient positioning
• New patient support for 3D imaging• Patient standing or sitting
•kV/mA automatically selected according to patient size (possibility to overdrive)
3D image volume location
Pre-programmed areas for• dentition • TMJ and ramus• Ear• Sinus• Vertebrae• Airways
• Position adjustment possible with SCARA arm• Fine adjustment with joystick• Easy positioning
3D image volume sizes
(dia mm x height mm)•Full Size 80 x 80•Maxilla 80 x 50 •Mandible 80 x 50•Molar Maxilla 40 x 50•Molar Mandible 40 x 50
•Programs to match diagnostic task
•Minimize radiated volume
Stitching – 3D Large View•Stitches 2 or 3 volumes
together horizontally or vertically
• Increases the volume sizediameter -> 16cmheight -> ~13 cm
Stitching – 3D Large View
Stitching examples
Imaging modes• High resolution mode
• Very high resolution for high precision imaging
• 0.16 mm voxel• Effective exposure time 12 s• Patient dose 50% lower than
before• Normal resolution mode
• High resolution with 50% lower dose
• 0.32 mm voxel• Effective exposure time 12 s• Optimized for implant planning in
Simplant and Procera• Small volume size 30 MB
• Low dose mode• 0.32 mm voxel, lower resolution • Effective exposure time 2.8 s• 90% lower dose• Small volume size 30 MB• Used in Large View mode
Planmeca Romexis
Planmeca Romexis software modules for 3D imaging
• 3D Explorer• 3D panoramic view• Implant planning• 3D Viewer• DICOM
Comprehensive viewing tools
Planmeca Romexis 3D Explorer
•3D volume viewing:• Image acquisition•sagittal, coronal and axial
views•real time adjustable
viewing angles•contrast & brightness•measurements•export as DICOM•Quick Launch
•Fast and convenienat multi-planar projection viewing
Planmeca Romexis 3D Panoramic module
• Focal through path defined by user on axial view • Layer thickness selectable
and constant• No redundant shadows or
artefacts• Constant magnification• Free selectable panoramic
layer
conventional pan
3D panoramic view
Planmeca Romexis 3D panoramic
No redundant shadows
Planmeca Romexis 3D Cross Sections and Implant planning modules•3D panoramic with
adjustable cross section views
•Mandibular nerve marking•Measurements•Implant placement•Implant models
Planmeca Romexis 3D Viewer
•Included in CD with 3D studies
•Basic viewing and measurements
•Includes Explorer, Panoramic and Cross Section views depending on master licence
•Requires Java•Enables 3D study viewing
remotely
Planmeca Romexis 3D DICOM
•Standard:•DICOM media import/export•DICOMDIR import export
•Optional:•DICOM Storage•DICOM Print•DICOM Worklist• ....
3D image transfers via DICOM
3D Quick Launch
Planmeca Romexis 3D Explorer with Quick Launch Button• Starts alternative implant planning software through
DICOM : Simplant, Cybermed N-Liten3D • Transfers open patient study and patient ID
• Fast and convenient integration:• Romexis 3D Explorer is used to control and acquire
ProMax 3D study• 3rd party software is used to manipulate the study as
desired
Planmeca ProMax 3D and Cephalometry
•Digital Ceph ideal for cephalometry• all information for
orthodontic planning• lower radiation dose• faster procedure
•3D to be used for detailed e.g. occlusion views, inpacted teeth etc.if needed
•Same Promax unit for both studies
•Optimum for orthodontic imaging
3D Technology
• CBCT - Cone Beam Computed Tomography• CBVT - Cone Beam Volume
Tomography
• Technological advance from traditional fan beam CT• Image data is a cylinder,
not a set of single slices
• Click here to play movie
Windows Media Audio/Video file
3D Technology
•One 18 second scan•194 degrees scan angle•300 snap shot images
taken with synchronized X-ray pulses
•Stroboscopic effect for maximum clarity of the images
•Accumulated X-ray exposure time is 2.8 – 8.3seconds – reduced dose
3D Technology
Pulsed X-ray produces sharp images with less dose.
3D Technology
• 300 basic images• Proprietary 3D
reconstruction algorithm• Image volume is
8 x 8 cm cylinder of 120 million voxels
• Voxel size 160 x 160 x 160 µm
• Corresponds to 3 lp/mm (Nyquist)
X-ray Tube – Patient – Image Intensifier – TV Camera – Digital Image
X-ray Tube – Patient – Flat Panel- Digital Image
Modern Flat Panel Technology for maximum performance
3D Technology – Flat Panel
Planmeca ProMax 3D flat panel imaging chain
Conventional imaging chainwith Image Intensifier
3D Technology – Flat Panel
•Image intensifier has both distortion and brightness non-uniformity which is absent from the flat panel detector
•Image intensifier needs periodical maintenance. It has limited life span 3-6 years.
• It is sensitive to magnetic or electrical fields.
• It is over 60 years old technology.
3D technology – Tube Current Modulation
• Different attenuation properties across and along the patient's head
• Tube current (mAs) can be dynamically adjusted
• Reduces patient dose and improves image quality
more
less
Medical CT is decades old technology
3D vs Medical CT
•Planmeca ProMax 3D: •cone beam•194 degrees = half a circle •18 seconds scan•6 seconds pulsed X-ray
•Medical CT with 0.6 mm slice:
•fan beam•16 spiral rounds•continuous X-ray
Planmeca Promax 3D and N-Liten
Planmeca ProMax 3D works with N-Liten
Planmeca ProMax 3D and Simplant
Planmeca ProMax 3D works with Simplant
Nobel Guide impression with markers
Planmeca ProMax 3D and Procera
Planmeca ProMax 3D works with Procera/NobelGuide
Radiation dose
• Radiation dose of CBCT 30- 900 µSv
• Same level as 5-10 panoramic images
• Same level as full mouth series with film
• Essentially lower than medical CT• ProMax 3D 45-200 µSv (8 x 8 cm),
18 – 80 µSv (4 x 5 cm)
Low radiation dose compared to medical CT
Medical CT 1200-3300 uSvDr Stuart White, UCLA
Dig. Pan 4.7-14.9 uSvFMS 150 uSvDr Sharon Brooks, O of Michigan
Planmeca ProMax 3D vs Sirona GalileosPlanmeca Promax 3D Sirona Galileos
Floor space 1.2 x 1.2 m 1.6 x 1.6 m
With Pan/Ceph yesNo •additional office space needed
Patientseated/standing•flexible, faster
seated
Sensor type flat panelImage Intensifier•geometric distortion
Field of view, cm8x8, 8x5, 4x5, cylinder•FOV selectable to diagnostic task
15x15, sphere
Rotation location movable (SCARA robot arm) fixed
Radiated volume for complete dentition
8x8 cm, 402 cm3
15x15 cm 2650 cm3
•6x more radiated volume for the same clinical need
Radiated volume for single jaw implant study
8x5 cm, 251 cm3 15x15 cm 2650 cm3
•10x more radiated volume
Radiated volume for a molar implant study
4x5 cm, 63cm3 15x15 cm 2650 cm3
•42x more radiated volume
Planmeca ProMax 3D vs Sirona GalileosPlanmeca Promax 3D Sirona Galileos
Voxel size, mm0.16•smallest voxel
0.3
Gray scale 12 bit ?
Scan angle194 deg •less motion artefacts
270
Scan time 18 s 15 s
kV range50-84 kV•adjustable according to patient
size/age90 kV
mAs range12-90 mAs•more powerful generator
28 mAs
Pulsed X-ray yes yes
System calibration No need Periodical
Softwareintra, pan, ceph, 3D integrates to PMSQuick Launch
3D onlyisolated
Planmeca ProMax 3D vs i-CatPlanmeca Promax 3D I-Cat
Floor space 1.2 x 1.2 m 1.3 x 1.5 m
With Pan/Ceph yesno•additional office space needed
Patientseated/standing•flexible, faster
seated
Sensor type flat panel flat panel
Field of view, cm8x8, 8x5, 4x5, cylinder•FOV selectable to diagnostic task
16x22, 17x13, 17x11, 17x7, 17x4cm, cylinder
Rotation location movable (SCARA robot arm) fixed
Radiated volume for complete dentition
8x8 cm, 402 cm3
16x22 cm 4421 cm3
•11x more radiated volume17x11 cm 2496 cm3
•6x more radiated volume for the same clinical need
Radiated volume for single jaw implant study
8x5 cm, 251 cm317x7 cm 1588 cm3
•6x more radiated volume
Radiated volume for a molar implant study
4x5 cm, 63cm317x4 cm 908 cm3
•14x more radiated volume
Planmeca ProMax 3D vs i-CatPlanmeca Promax 3D I-Cat
Voxel size, mm0.16•smallest voxel
0.4, 0.3 (17x13), 0.2 (17x7)
Gray scale 12 bit 12 bit
Scan angle194 deg •less motion artefacts
360 deg
Scan time 18 s 10/20/40 s
kV range50-84 kV•adjustable according to patient
size/age
120 kV•additional radiation protection
needed•reduced contrast•more scatter
mA range2-15 mA•more powerful generator
3-8 mA
Pulsed X-ray yes yes
System calibration No need Daily
Softwareintra, pan, ceph, 3D integrates to PMSQuick Launch
3D onlyisolated
The End
More information:Erkki HiltunenProduct Manager, X-raystel: +358 20 7795 456 erkki.hiltunen@planmeca.com
More information:Osku SundqvistProduct Manager, Softwaretel: +358 20 7795 793osku.sundqvist@planmeca.com