PPS 400.3Three-phase Portable Power Source (12 A or 120 A / 300 V)

The PPS 400.3 is a powerful and portable three-phase current and voltage source. All test values are generated absolutely synthetically with a high degree of accuracy and stability.

The PPS 400.3 is available in two versions:• PPS400.3-12A(maximumcurrentupto12A)• PPS400.3-120A(maximumcurrentupto120

A)

The PPS 400.3, portable power source may beused as enhancement of the reference standardPRS 400.3 as well as independently. The control software automatically recognises the model. Itmaythereforeimmediatelybetakenintooperation,andautomaticmeasurementofaloadcurveofthemetermaybegin.

Advantages of the PPS 400.3• Three-phaseportableprecisiontypesource

withsingle-phasemainssupply• Currentandvoltagesourcefacilitiescanbe

selected independently• Current,voltageandphaseshiftare

adjustabletohighaccuracybyusingkeys• Thevaluesareshownonadisplayandcan

bereadoutviatheRS232Cinterface• Thevaluessetarestabilisedbydigitaland

analogue control IntegratedRS232Cinterfaceforexternal

programcontrolviaPC.Itispossibletoreadout the current and voltage values

• Generationofharmonics(upto31th)• ThePortableControlModulePCS400.3can

be on a stand-alone basis and the power source is in this application controlled via blue-tooth

Options• SoftwareCAMCALforWindowsorCALSOFT

Manufacturedby:

BM-PPS400.3 /1

w w w. p p i . p h

Technical data PPS 400.3 + PCS 400.3Model Description PPS 400.3-12 A PPS 400.3-120 A

Supplyvoltage 88V…280V,45…65HzPowerconsumption max.300VA max.500VAHousing Metal,rubberprotection DimensionsWidthxHeightxDepth 520x195x365mm 520x195x365mmWeight approx.20.5kg approx.23.5kgAmbienttemperature Operating/Specifiedrange -10°C…+50°C/+10°C…+40°CInfluenceofauxiliaryvoltage _<0.005%at10%variationonthemeasuringresultsFrequencyrange 45…400HzFrequencyresolution 0.01HzPhaseanglerange -180°…+180°Phaseangleresolution 0.01°Phaseangleerror _<0.1°

Voltage sourceVoltagerange Phase-Neutral 3x0V…3x300V/520VInternalranges/Peakvalues Range Peakvoltage Power/Peakcurrent 150V…300V 467V 50VA/0.26A 75V…150V 233V 50VA/0.52A 30V…75V 117V 50VA/1.04AResolution atthefinalrangevalue 0.01%Adjustmenterror atthefinalrangevalue <0.05%Distortionfactor onlinearLoad <0.5%Stability Timebase5s betterthan0.05%/2min Timebase150s betterthan0.005%/hLoadregulation 0%-100%Load <0.01%Powerfactorofload 0.1lead…1…0lagEfficiency >85%

Current sourceCurrentrange 3x1mA…3x12A 3x1mA…3x120AInternalranges/Peakvalues Range Peakcurrent Power/Peakvoltage Power/Peakvoltage 80A…120A 187A --- 80VA/1.04V 12A…80A 124A --- 80VA/1.56V 1.2A…12A 18.7A 30VA/3.89V 80VA/10.4V 120mA…1.2A 1.87A 3VA/3.89V 8VA/10.4V 12mA...120mA 187mA 0.3VA/3.89V 0.8VA/10.4V 1mA...12mA 18.7mA 0.1VA/3.89V 0.1VA/10.4VResolution atthefinalrangevalue 0.01%Adjustmenterror atthefinalrangevalue <0.05%Distortionfactor onlinearLoad <0.5%Stability Timebase5s betterthan0.05%/2minStability Timebase150s betterthan0.005%/hLoadregulation 0%-100%Load <0.01%Powerfactorofload 1...0.1lagEfficiency >85%

Generation of harmonicsFundamentalfrequencyrange 45…65HzAmplitude 2.-6.Harmonics max.40% 7.-31.Harmonics max.10%Sumofallharmonics max.40%Sumof7.-31.harmonics max.10%Phaseshift Basicwaveform/harmonic 0°...360°

Safety RequirementsCE-certifiedIsolationprotection accordingEN61010-1Degreeofprotection IP-40Storagetemperature -20°C...+55°CRelativehumidity _<85%atTa_<21°CRelativehumidityat30days/year _<95%atTa_<21°C