power supply · 2015. 2. 23. · power supply temp coefficient insulation resistance dielectric...

Post on 10-Feb-2021

6 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

  • POWER SUPPLY

    CONVERTER A-35

    MODEL & SUFFIX CODE SELECTION

    GENERAL SPECIFICATIONS

    •••••

    Power Supply

    Temp Coefficient

    Insulation Resistance

    Dielectric Strength

    Operating Temperature/Humidity

    Storage Temperature/Humidity

    Dimensions

    Case Material

    Weight

    Mounting

    AC rating ±10%, approx. 4VA

    ±0.015% / ℃(±0.008%/℉)

    Greater than 100MΩ with DC 500V

    Input — Power

    GND — Power

    –20~60℃ / 90%(N.C)

    –20℃~80℃ / 95%(N.C)

    8 pin:W50×H85×D122(mm)

    11 pin:W50×H85×D133(mm)

    ABS Resin (black)

    about 400g

    Wall & Rail mounting

    AC 2500V

    AC 1000V 1 minute

    A : DC 12V(4~20mA)

    B : DC 24V(4~20mA)

    C : Only Power:200mA

    D : DC 12V(4-20mA) 2 Point Input

    E : DC 24V(4-20mA) 2 Point Input

    F : Other

    A :1~5V E : DC 12V

    B : 4~20mV F : DC 24V

    C:1~5V 2 Point Output G : DC 12V 2 Point Output

    D : 4~20mA H : DC 24V 2 Point Output

    2 Point Output I : Other

    U : AC 100V X : AC 24V

    V : AC 110V Y : DC 24V(option)

    W: AC 220V

    신호1~64.ps 2011.3.23 4:50 PM 페이지50 Mac-16

  • BLOCK DIAGRAM

    INPUT & OUTPUT SPECIFICATIONS

    1 Point Output

    1. Current Loop(4~20mA)

    2. Only power Supply:200mA(Max)

    1 Point Output

    SIGNAL TRANSMITTER

    CONVERTER A-36

    Input Specification Output Load Resistance

    Specification

    Supply range

    Current rating

    Current limited

    Report

    24~28V(with no Ioad)

    22mA(Max)

    30mA(Max)

    Signal

    1~5V

    4~20mA

    Load Resistance

    250Ω(Min)

    1.2kΩ(Max)

    2 Point Output

    2 Point Output

    신호1~64.ps 2011.3.23 4:50 PM 페이지51 Mac-16

    0323알컴-신호001~064 510323알컴-신호001~064 52

top related