Sizing Pipeline diameter with required pressure drop and allowable velocity

TRANSCRIPT

Sheet1Reference :API RP 14 EDATAP1, upstream pressure550psig564.7psiaS, spesific Gravity0.72Z, Compressibility Factor0.8686Qg, gas flow rate 70MMSCFDT1, gas inlet temperature85oF545oRL, Length of Pipe14850m100ftOD16inWall Thickness0.375inID15.25inE0.95

PRESSURE DROP CALCULATIONMetode WeymouthMetode PanhandleA1,602.0A6.86B0.0019093659B45.0014648899C65.08P2, downstream pressure564.66P2, downstream pressure564.64psia549.96psig549.94psigPressure drop0.04psi/100 ftOKPressure drop0.06psi/100 ftOK

SyaratMax1psi/100 ft

GAS VELOCITY CALCULATIONGas Velocity15.14ft/sOK

Syarat10-60ft/s0.070.0762716625