Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
1 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MODULE - 1 INTRODUCTION TO MECHATRONICS
SCOPE OF MECHATRONICS
Mechatronics is considered as an application of computer based digital control
technique via electric and electronic interfaces to solve mechanical engineering
problems. Mechatronics is a synergic combination of mechanical and electrical
engineering, computer science and information technology, which includes control
systems as well as numerical methods used to design products with built-in-
intelligence. A mechatronic system requires multi-disciplinary approach for its design,
development and implementation. In mechatronics, entire electro mechanical system is
treated concurrently in an integrated manner by a multidisciplinary team of engineers
and other professionals. There are many applications of mechatronics in mass
production, which are used in industrial and house hold situations. Examples of
mechatronics products include digital cameras, microwave oven, heating control, and
automatic material conveying systems etc. A humanoid robot is another intelligent
mechatronic system. It may involve many servomotors and a variety of other
mechatronic components. Mechatronic components are more efficient, and cost
effective, precise, accurate, reliable and flexible and have mechanically fewer
complexities.
A mechatronic system consists of a mechanical skeleton, actuators, sensors,
controllers, signal conditioning/ modification devices, computer /digital hardware and
software, interfacing device and power sources. Mechanical systems frequently consists
of more than just mechanical components and may include fluid ,pneumatic, thermal,
acoustic, chemical, or other elements as well . Sensor detects the quantity that is being
measured (measurand), while the transducer converts the detected measurand into a
convenient form for subsequent use (recording, control and actuation). The transducer
signal may be filtered, amplified and suitably modified prior to this. Transfer function
models (in frequency domain) are useful in representing, analyzing, designing and
evaluating sensors, transducers, controllers, actuators and interfacing devices.
What is mechatronics?
The term mechatronics is used for the integration of microprocessor control
systems, electrical systems and mechanical systems. A mechatronic system is not just a
marriage of electrical and mechanical systems and is more than just a control system; it
is a complete integration of all of them. In the design of cars, robots, machine tools,
washing machines, cameras, and very many other machines, such an integrated and
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
2 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
interdisciplinary approach to engineering design is increasingly being adopted. The
integration across the traditional boundaries of mechanical engineering, electrical
engineering, electronics and control engineering has to occur at the earliest stages of the
design process if cheaper, more reliable, more flexible systems are to be developed.
Mechatronics has to involve a concurrent approach to these disciplines rather than a
sequential approach of developing, say, a mechanical system then designing the
electrical part and the microprocessor part.
Definition of mechatronics
A mechanical system designed to execute a desired function works under the
input parameters like force torque pressure heat etc to produce respective units like
translation rotation expansion and deformation .When the extraction of information’s
input to a system is carried out by sensors and the output information is extracted by
actuators to be processed by a controller (preferably microprocessor based) so that the
desired function is executed with specified accuracy by the action of feed back process it
would represent a mechatronic system. Such an arrangement is generally illustrated by
the block diagram given in figure.
Fig : Definition of Mechatronics
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
3 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
In the representation provided the mechanism is a mechanical system .The
sensors are electrical/ electronic. Actuators can be mechanical/ electrical. Microprocessor
based controllers are electronic. Hence the total system is the integration of mechanical,
electrical and electronic sub-systems arranged to produce an accurate process or
function automating the output. With the addition of computers the mechatronic
system becomes more sophisticated and flexible.
To define mechatronics with single sentence “Mechatronics is the synergistic
integration of mechanical engineering with electronics and electrical with intelligent computer
control in the design and manufacture of industrial products, processes and operations”.
SYSTEMS
The mechatronic system is made of several systems like measurement system,
drive and actuation system, control system, microprocessor system, and computer
system. The characteristics of each system are
i) System: A system can be thought of as a box which has an input and an output and
where we are not concerned with what goes on inside the box but only the relationship
between the output and the input. Thus, for example, a motor may be thought of as a
system which has as its input electric power and as output the rotation of a shaft. Figure
shows a representation of such a system.
Fig : An example of a system
Any mechanical, electrical or electronic element or set of elements that can give
out certain useful outputs under the understandable inputs can be named the system.
The system can be purely mechanical, electrical or electronic requiring compatible
inputs. But the mechatronic system is the combination of these systems. The schematic
of a system is given in figure.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
4 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
ii) Measurement System: A measurement system can be thought of as a black box which
is used for making measurements. It has as its input the quantity being measured and
its output the value of that quantity. For example, a temperature measurement system,
i.e. a thermometer, has an input of temperature and an output of a number on a scale.
Figure shows a representation of such a system.
Fig: An example of a measurement system
Any system that measures parameters like temperature, pressure, force, voltage,
current, etc can be considered to a measurement system. For example a pressure gauge
receives pressurized fluids through a pipe and the deformation of a flexible copper tube
is converted to dial indication (analogue) by the rotation of a pinion. Such a system is
shown below.
iii) Control System: A control system can be thought of as a black box which is used to
control its output to some particular value or particular sequence of values. For
example, a domestic central heating control system has as its input the temperature
required in the house and as its output the house at that temperature, i.e. you set the
required temperature on the thermostat or controller and the heating furnace adjusts
itself to pump water through radiators and so produce the required temperature in the
house. Figure shows a representation of such a system.
Fig : An example of a control system
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
5 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MEASUREMENT SYSTEMS
Measurement systems can, in general, be considered to be made up of three
elements (as illustrated in Fig.):
1. A sensor which responds to the quantity being measured by giving as its output
a signal which is related to the quantity. For example, a thermocouple is a
temperature sensor. The input to the sensor is a temperature sensor. The input to
the sensor is a temperature and the output is an e.m.f. which is related to the
temperature value.
2. A signal conditioner takes the signal from the sensor and manipulates it into a
condition which is suitable for either display or in the case of a control system,
for use to exercise control. Thus for example, the output from a thermocouple is a
rather small e.m.f. and might be fed through an amplifier to obtain a bigger
signal. The amplifier is the signal conditioner.
3. A display system where the output from the signal conditioner is displayed. This
might, for example, be a pointer moving across a scale or a digital readout.
As an example consider a digital thermometer. This has an input of temperature to a
sensor, probably a semiconductor diode. The potential difference across the sensor is, at
constant current, a measure of the temperature. This potential difference is then
amplified by an operational amplifier to give a voltage which can directly drive a
display. The sensor and operational amplifier may be incorporated to the same silicon
chip.
Fig : A measurement system and its constituent elements
The resistance strain gauges mounted on a loaded beam in the form of a
Wheatstone’s bridge give change in voltage by change in resistance owing to change in
length by deformation. The differential amplifier amplifies the voltage signal that is
given to analogue or digital strain indicator to give out the strain reading as the output.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
6 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MICROPROCESSOR BASED CONTROLS
Microprocessors are now rapidly replacing the mechanical cam-operated
controllers and being used in general to carry out control functions. They have the great
advantage that a grater variety of programs become feasible. In many simple systems
there might just an embedded microcontroller, this being a microprocessor with
memory all integrated on one chip, which has been specifically programmed for the
task concerned. A more adaptable form is the programmable logic controller. This is a
microprocessor-based controller which uses programmable memory to store
instructions and to implement functions such as logic, sequence, timing counting and
arithmetic to control events and can be readily programmed for different tasks. Fig.
shows the control action of a programmable logic controller, the inputs being signals
from switches being closed and the program used to determine how the controller
should respond to the inputs and the output it should then give.
Fig : Programmable Logic Controller
The mechanical mechanisms like speed governors, cam actuated valves and
switches, rack and pinion driven analog indicators are being replaced by
microprocessor based controllers. The main features of microprocessor controllers are
• Variety of programs can process the multiple inputs to give multiple outputs.
• The programs can be altered/ reprogrammed to change the output specifications.
• There is programmable memory to store instructions and carry out control
functions.
• The processors being integrated chips are compact in size embedded in any
circuit
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
7 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
THE MECHATRONICS APPROACH
The Domestic Washing machine that used cam-operated switches in order
to control the washing cycle is now out-of-date. Such mechanical switches are being
replaced by microprocessors. A microprocessor may be considered as being
essentially a collection of logic gates and memory elements that are not wired up
as individual components but whose logical functions are implemented by means
of software. The microprocessor - controlled washing machine can be considered
an example of a mechatronics approach in that a mechanical system has become
integrated with electronic controls. As a consequence, a bulky mechanical system
is replaced by a much more compact microprocessor system which is readily
adjustable to give a greater variety of programs.
Mechatronics involves the bringing together of a number of technologies :
mechanical engineering , electronic engineering , electrical engineering , computer
technology and control engineering . This can be considered to be the application
of computer based digital control techniques , through electronic and electric
interfaces , to mechanical engineering problems. Mechatronics provide an opportunity
to take a new look at problems with mechanical engineers not just seeing a problem in
terms of mechanical principle but having to see it in terms of a range of technologies.
The electronics, etc., should not be seen as bolt-on item to existing mechanical
hardware. A mechatronic approach needs to be adopted right from design phase .There
needs to be a complete rethink of the requirements in terms of what an item is required
to do.
There are many applications in the mass-produced products used in the home.
The microprocessor-based controllers are to be found in domestic washing machines,
dish washers, ovens, cameras, camcorders, watches, hi-fi and video recorder systems,
central heating controls, sewing machines, etc. They are to be found in cars in the active
suspension, antiskid brakes, engine control, speedometer display, transmission etc.
A larger scale application of mechatronics is a flexible manufacturing
engineering system (FMS) involving computer-controlled machines, robots, automatic
material conveying and overall supervisory control.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
8 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Advantages and Disadvantages of Mechatronics.
S. No. Advantages of Mechatronic Systems S. No. Disadvantages of Mechatronic Systems
1. Serves effectively high dimensional
accuracy requirements. 1.
Improves application and under
utilization can result in losses.
2.
Mechatronic systems provide
increased productivity on the shop
floor.
2. Maintenance and repair may workout
costly.
3.
Reconfiguration feature by pre
supplied programs facilitate the low
volume production.
3. The initial cost is high.
4. Provides higher level of flexibility
required for small product cycles. 4.
Techo-econic estimation has to be done
carefully in the selection of
mechatronic system.
5.
Manufacturing lead time is reduced
resulting in lowering of unit cost
especially in mass production.
5.
Calls for training and re-orientation of
the work force, in design and
manufacture.
6. Results in automation in production,
assembly and quality control. 6.
The technicians and engineers have to
be given basic knowledge of two
domain disciplines viz. Precision
mechanics and electronics.
7.
Plays major role in total
manufacturing solutions rather than
stand alone machines.
7.
The concurrent integration of
mechatronic design needs expertise of
multidisciplinary knowledge.
8.
Production of parts and products of
international standards gives better
reputation and return.
9.
Higher life is expected by proper
maintenance and timely diagnosis of
the fault.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
9 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
SENSORS AND TRANSDUCERS
The term sensor is used for an element which produces a signal relating to the
quantity being measured. Thus in the case of an electrical resistance temperature
element, the quantity being measured is temperature and sensor transforms an input of
temperature into a change in resistance. The term transducer is often used in place of the
term sensor. They are defined as elements that when subject to some physical change
experience a related change. Thus sensors are transducers. However a measurement
system may use transducers, in addition to the sensor, in other parts of the system to
convert signals from one form to another form.
Definition of sensor
“It is a part of the measurement system that provides response to the particular
measurable physical parameter, which can be one of the input energy domain
transformed into another form of energy domain with or without aid of modulating
energy domain”.
The six energy domains identified to accept, transfer and modulate by a sensor are
v Mechanical. Distance, velocity, force, acceleration or size etc. are covered in this
domain.
v Electrical. Current, resistance, voltage, inductance, capacitance form the basis of
this domain.
v Magnetic. Field strength and flux density can be considered in this domain.
v Thermal. The effect of temperature like heat capacity, latent heat, phase changes,
sensible heat, superheating can be identified in this domain.
v Radiant. The frequency, phase, intensity, polarity of electromagnetic radiation
fall in this domain.
v Chemical. The concentration of the chemical substances crystal structure, and
aggregation of state concerning the behaviors of the matter exemplify this
domain.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
10 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Classification of Sensors
The static and dynamic performance characteristics play important role in the
selection of the type of sensors needed for the applications suitable to the mechatronic
system. The range, error, accuracy, sensitivity, repeatability, stability and resolution are
some of the static performance parameters to be looked into before selecting a right
sensor. Response time, rise time, settling time and time constant are the main dynamic
characteristics usually considered in mechatronic application of sensors.
i) Pressure Sensors
The mechanical pressure gauge with collapsible tube and analogue indication is
the most beginning in pressure measurement which still finds application in mechanical
industries.
In fluid power systems with dynamic fluctuations electrical pressure sensors are
preferred. In these the elastic deformations depending upon the materials physical
properties, are transformed into electrical signal. The strain gauges find the frequent
usage in pressure measurements.
Piezoelectric sensors are most suitable for dynamic pressure measurements and
small in size. For both static and dynamic pressure signals best solutions are
piezoresistive sensors. Vapour deposited thick film sensors on silicon wafers constitute
the measuring element. The signal gets amplified by the integrated differential
amplifier. This has the disadvantage of being sensitive to temperature changes.
ii) Flow Sensors
The result of flow management is influenced by the parameters like pressure
pulsation, temperature, and viscosity of the flow medium. The principle of flow
measurement is fraught with the effects of flow captured via physical properties and
then transformed into a signal proportional to volume flow. Knowing the cross-section
of the medium at a point where the velocity of the stream is measured to obtain the
flow rate.
Gear pump can be used for measure flow with high accuracy. But they have the
drawbacks of higher pressure loss and are prone to seizing due to contaminations.
Measuring turbine is another mechanical application of flow measurement in which the
flow drives the turbine wheel that induces an electrical impulse for each blade.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
11 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
iii) Hall Effect Sensors
E.R. Hall in 1879 discovered the Hall Effect. “A beam of charged particles
passing through a magnetic field experience a force that defect the beam from the
straight line path”. This is known as Hall Effect.
Electrons (negative charged particles) are made to pass through a plate of
rectangular cross section and a magnetic field is applied at right angle to the plane of
the plate as shown in fig. The electrons are deflected towards one side of the plate,
making that side negatively charged and the other side becomes positively charged. The
force due to the applied magnetic field is called Lorentz force. The mechanism of
deflection is governed by the balance in Lorentz force and the force on the charged
particle due to electric field.
Fig : Principle of Hall effect
The potential difference, V, created in between the transverse face of the plate, is
given by
t
T F H V L
c=
Where, HC = Hall’s co-efficient
FL = Magnetic flux density due to Lorentz force
I = Current flowing through the plate
t = Thickness of the plate
V = Hall voltage
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
12 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
iv) Light Sensors
Any radiation of appropriate wavelength fall on the depletion layer of p-n
junction develops a potential difference between the junctions. The voltage across the
layer is proportional to the illumination of the incident radiation. Figure (a) shows the
incidence on light rays on the n layer of the p n junction. Figure (b) is the characteristic
curve showing the variation of voltage with wavelength of radiation.
Type of Light sensors
1. Photo diodes
2. Photo transistors
3. Photo conductors
Photo Diodes: The reverse bias is applied against the p-n junction that results in a very
high resistance. The light ray is made to fall on n-layer (depletion layer). This results in
decrease in resistance of diode, developing a reverse current due to the sweep up of the
electron-hole pair. The reverse current is the measure of intensity of the incident
radiation. The response of photo diodes is quick and they can be used as variable
resistance devices.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
13 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Photo Transistors: A base-collector arranged in parallel to the photo diode a bipolar
transistor is formed. In this PN junction collector-base is photo sensitive. The incident
radiation on the base results in reverse current of photodiode, which is base current of
the transistor. The base current is proportional to the intensity of light. The internal
signal processing amplifies the base current to give higher sensitivity to the photo
transistors.
Photo Conductors: By coating a layer of indium antimonide (InSb) or cadmium
sulphide (CdS) on a layer of silicon dioxide (SiO2) the photo resistors are produced. The
base is the p-type material (SiO2) and n-type materials (In or CdS) are diffused on it. The
incident light ray illuminating the n-type layer results in change of conductivity. The
bridge circuit arrangement detects this change by the change in output voltage
proportional to the intensity of incident light. The photo resistor design and the
required circuitry are shown in figure.
Fig: Photo conductor, structure and bridge
v) Optical Sensor
The proximity of the object is detected by the action of the travelling light move.
The light emitted by the transmitter focuses on the object which reflects to be received
by the receiver photo diode. The constructional feature of the optical sensor is shown in
figure. The light from the emitting diode is focused by the transmitter lens, on to the
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
14 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
object surface. The reflected light waves travel back and received by the solid state
photodiode through the receiver lens. The object within the range of sensor can detect
the presence. The focal length of the sensor lenses decide the range within which the
proximity of the object is detected.
Fig: Optical Sensor
Transducers
Transducer is a pedantic word formed from two Latin words. By definition the
transducer is that part of a system that transfers information or data in the form of
energy from one part of the system to another with or without changing the form of
energy containing the informations.
Some of the Parameters transduced by electro-mechanical devices are as follows:
Force, Pressure, Temperature, Displacement, Proximity, Viscosity, Flow, Frequency,
Time, Vibration and Chemical composition.
Transducers are classified as
1. Electrical (Resistive, Capacitive, Inductive, Thermo electric, Resonant etc.)
2. Solid State (Magnetic, Thermal, Mechanical, Chemical etc.)
3. Optical (Radian energy, Photo detector, Vision system, Laser scanning,
Fiber optic etc.)
4. Piezo-electric (Accelerometer, Humidity meter, Light Modulators, Actuators,
Acoustic devices etc.)
5. Ultrasonic (Flow measurement, Distance, Velocity, Ultrasonic imaging etc.).
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
15 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
DISPLACEMENT, POSITION AND PROXIMITY
Displacement sensors are concerned with the measurement of the amount by
which some object has been moved; position sensors are concerned with the
determination of the position of some object with reference to some reference point.
Proximity sensors are a form of position sensor and are used to determine when an
object has moved to within some particular critical distance of the sensor. They are
essentially devices which give on-off outputs.
In selecting a displacement, position or proximity sensor, consideration has to be
given to:
1. The size of displacement.
2. Whether the displacement is linear or angular.
3. The resolution required.
4. The accuracy required.
5. What material the measured object is made of.
6. The cost.
Displacement and position sensors can be grouped into two basic types: contact
sensors in which the measured object comes into mechanical contact with the sensor or
non-contacting where there is no physical contact between the measured object and the
sensor. The following are the examples of commonly used displacement sensors.
1. Potentiometer sensor
A potentiometer consists of a resistance element with a sliding contact which can
be moved over the length of the element. Such elements can be used for linear or rotary
displacements, the displacement being converted into potential difference. The rotary
potentiometer consists of a circular wire-wound track or a film of conductive plastic
over which a rotatable sliding contact can be rotated.
The track may be single turn or helical. with a constant input voltage Vs,
between the terminals1 and 3, the output voltage Vo between terminals 2 and 3 is a
fraction of the input voltage, the fraction depending on the ratio of the resistances R23
between terminals 2 and 3 compared with the total resistance R13 between terminals 1
and 3, i.e. Vo/Vs=R23/R13. If the track has a constant resistance per unit length, i.e. per unit
angle, then the output is proportional to the angle through which the slider has rotated.
Hence the angular displacement can be converted into potential difference.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
16 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Rotary Potentiometer
With a wire-wound track the slider in moving from one turn to the other will
change the voltage output in steps, each step being a movement of one turn. If the
potentiometer has N turns then the resolution, as a percentage, is 100/N. Thus the
resolution of a wide track is limited by the diameter of the wire used and typically
ranges from about 1.5 mm for a coarsely wound track to 0.5 mm for a finely wound one.
Errors due to non-linearity of the track tend to range from less than 0.1% to about 1%.
The track resistance tends to range from about 20 Ω to 200 kΩ. Conductive plastic has
ideally infinite resolution, errors due to non-linearity of track of the order of 0.05% and
resistance values from about 500 Ω to 80 kΩ. The conductive plastic has a higher
temperature coefficient of resistance than the wire and so temperature changes have a
greater effect on accuracy.
2. Strain-gauged element
The electrical resistance strain gauge (in fig) is a metal wire, metal foil strip, or a
strict of semiconductor material which is water-like and can be stuck onto surfaces like
a postage stamp.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
17 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig: Strain gauges: (a) metal wire, (b) metal foil, (c) semiconductor
When subjected to strain, its resistance R changes, the fractional change in resistance
∆R/R being proportional to the strain ε, i.e.
εG R
ΔR=
Where G, the constant of proportionality, is termed the gauge factor. Since strain is the
ratio (change in length/ original length) then the resistance change of a strain gauge is a
measurement of the change in length of the element to which the strain gauge is
attached. The gauge factor of the metal wire or foil strain gauges with the metals
generally used is about 2.0. silicon p-type and n-type semiconductor strain gauges have
gauge factors of about +100 or more for p-type silicon and -100 or more for n-type
silicon. The gauge factor is normally supplied by the manufacturer of the strain gauges
from the calibration made of a sample of strain gauges taken from a batch. The
calibration involves subjecting the sample gauges to known strains and measuring their
changes in resistance. A problem with all strain gauges is that their resistance not only
changes with strain but also with temperature. Semiconductor strain gauges have a
much greater sensitivity to temperature than metal strain gauges.
3. Capacitive element
The capacitance c of a parallel capacitor is given by
d
A ε ε C or=
Where εr is the relative permittivity of the dielectric between the plates, εo a constant
called the permittivity of free space, A the area of overlap between the two plates and d
the plate separation. Capacitive sensors for the monitoring of linear displacements
might thus take the forms shown in figure. In (a) one of the plates is moved by
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
18 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
displacement so that the plate separation changes; in (b) the displacement causes the
area of overlap to change; in (c) the displacement causes the dielectric between the
plates to change.
Fig : Forms of Capacitive sensing element
For the displacement changing the plate separation (Fig. (a)), if the separation d is
increased by a displacement x then the capacitance becomes:
xd
A ε ε ΔC-C or
+=
4. Differential transformers
The linear variable differential transformer, generally referred to by the
abbreviation LVDT, consists of three coils symmetrically spaced along an insulated
tube. The central coil is the primary coil and the other two are identical secondary coils
which are connected in series such a way that their outputs oppose each other. A
magnetic core is moved through the central tube as a result of displacement being
monitored.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
19 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : LVDT
When there is an alternating voltage input to the primary coil, alternating emf’s
are introduced in the secondary coils. With the magnetic core central, the amount of
magnetic material in each of the secondary coils is the same. Thus the emf’s induced in
each coil are the same. Since they are so connected their outputs oppose each other, the
net result is zero output.
However, when the core is displaced from the central position there is a greater
amount of magnetic core in one coil than the other, e.g. more in secondary coil 2 than
coil 1. The result is that a greater e.m.f. is induced in one coil than the other. There is
then a net output from the two coils. Since greater displacement means even more core
in one coil than the other, the output, the difference between the two emf’s increases the
greater the displacement being monitored.
Fig : LVDT output
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
20 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The emf induced in a secondary coil by a changing current i in the primary coil is
given by:
dt
diM e =
Where M is the mutual inductance, its value depending on the number of turns on the
coils and the ferromagnetic core. Thus, for a sinusoidal input current of i = I sinωt to the
primary coil, the emf’s induced in the two secondary coils 1 and 2 can be represented
by:
Φ)-sin(ωi k vand Φ)-sin(ωi k v 2211 ==
where the values of k1, k2 and φ depend on the degree of coupling between the primary
and secondary coils for a particular core position. φ is the phase difference between the
primary alternating voltage and the secondary alternating voltages. Because the two
outputs are in series, their difference is the output :
1 2 1 2Output voltage v -v (k -k ) sin (ωt-Φ)= =
when the core is equally in both the coils, k1 equals k2 and so the output voltage is zero.
When the core is more in 1 than in 2 we have k1 > k2 and:
1 2Output voltage (k -k ) sin (ωt-Φ)=
when the core is more in 2 than in 1 we have k1 < k2. A consequence of k1 being less than
k2 that there is a phase change of 1800 in the output when the core moves from more in 1
to more in 2. Thus:
[ ]1 2
2 1
Output voltage -(k -k ) sin (ωt-Φ)
(k -k ) sin ωt (π-Φ)
=
= +
A rotary variable differential transformer (RVDT) can be used for the
measurement of rotation; it operates on the same principle as that of an LVDT. The core
is a cardioid-shaped piece of magnetic material and rotation causes more of it to pass
into one secondary coil than the other. The range of operation is typically 0 40± degree
with a linearity error of about 0.5%± of the range.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
21 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
VELOCITY & MOTION
The following are the examples of sensors that can be used to monitor linear
angular velocities and detect motion. The application of motion detectors includes
security systems used to detect intruders and interactive toys and appliances, e.g. the
cash machine screen which becomes active when you get near to it.
1. Incremental encoder
The incremental encoder described in the previous section can be used for a
measurement as angular velocity, the number of pulses produced per second being
determined.
2. Tachogenerator
The tachogenerator is used to measure angular velocity. One form, the variable
reluctance tachogenerator, consists of a toothed wheel of ferromagnetic material which is
attached to the rotating shaft (in fig.). A pick-up coil is wound on a permanent magnet.
As the wheel rotates, so the teeth move past the coil and the air gap between the coil
and the ferromagnetic material changes. We have a magnetic circuit with an air gap
which periodically changes. Thus the flux linked by a pick-up coil changes. The
resulting cyclic change in the flux linked produces an alternating e.m.f in the coil.
Fig : Variable Reluctance Tachogenerator
If the wheel contains n teeth and rotates with an angular velocity ω, then the flux
change with time for the coil can be considered to be of the form:
tna ωcos 0 Φ+Φ=Φ
where Ф0 is the mean value of the flux and Фa the amplitude of the flux variation. The
induced e.m.f 'e' in the N turns of the pick-up coils is thus:
( ) tntne aa ωωω sin n N cos dt
d N-
dt
d N- 0 Φ=Φ+Φ=
Φ=
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
22 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
FORCE
A spring balance is an example of a force sensor in which a force, a weight, is
applied to the scale pan and causes a displacement, i.e. the spring stretches. The
displacement is then a measure of the force. Forces are commonly measured by the
measurement of displacements, the following method illustrating this.
1. Strain gauge load cell
A very commonly used form of force-measuring transducer is based on the use
of electrical resistance strain gauges to monitor the strain produced in some member
when stretched, compressed or bent by the application of the force. The arrangement is
generally referred to as a load cell. Figure shows an example of such a cell.
Fig : Strain gauge load cell
This is a cylindrical tube to which strain gauges have been attached. When forces
are applied to the cylinder to compress it, then the strain gauges give a resistance
change which is a measure of the strain and hence the applied forces. Since temperature
also produces a resistance change, the signal conditioning circuit used has to be able to
eliminate the effects due to temperature. Typically such load cells are used for forces up
to about 10 MN, the non-linearity error being about ± O.03 % of full range, hysteresis
error ± O.02 % of full range and repeatability error ± 0.02 % of full range. Strain gauge
load cells based on the bending of a strain-gauged metal element tend to be used for
smaller forces, e.g. with ranges varying from 0 to 5 N up to 0 to 50 kN. Errors are
typically a non-linearity error of about ± 0.03 % of full range, hysteresis error ± 0.02 % of
full range and repeatability error ± 0.02 % of full range.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
23 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
FLUID PRESSURE
Many of the devices used to monitor fluid pressure in industrial processes
involve the monitoring of the elastic deformation of diaphragms, capsules, bellows and
tubes. The types of pressure measurements that can be required are: absolute pressure
where the pressure is measured relative to zero-pressure, i.e. a vacuum, differential
pressure where a pressure difference is measured and gauge pressure where the
pressure is measured relative to the barometric pressure.
Fig : Diaphragms: (a) flat, (b) corrugated
For a diaphragm (Fig.(a) and (b)), when there is a difference in pressure between
the two sides then the centre of the diaphragm becomes displaced. Corrugations in the
diaphragm result in a greater sensitivity. This movement can be monitored by some
form of displacement sensor, e.g. a strain gauge, as illustrated in figure given below. A
specially designed strain gauge is often used, consisting of four strain gauges with two
measuring the strain in a circumferential direction while two measure strain in a radial
direction. The four strain gauges are then connected to form the arms of a Wheatstone
bridge. While strain gauges can be stuck on a diaphragm, an alternative is to create a
silicon diaphragm with the strain gauges as specially doped areas of the diaphragm.
Fig : Diaphragm Pressure Gauge
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
24 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
TEMPERATURE
Changes that are commonly used to monitor temperature are the expansion or
contraction of solids, liquids or gases, the change in electrical resistance of conductors
and semiconductors and thermoelectric e.m.f.s. The following are some of the methods
that are commonly used with temperature control systems.
1. Bimetallic strips
This device consists of two different metal strips bonded together. The metals
have different coefficients of expansion and when the temperature changes the
composite strip bends into a curved strip, with the higher coefficient metal on the
outside of the curve. This deformation may be used as a temperature-controlled switch,
as in the simple thermostat which was commonly used with domestic heating systems.
The small magnet enables the sensor to exhibit hysteresis, meaning that the switch
contacts close at a different temperature from that at which they open.
Fig : Bimetallic Thermostat
2. Resistance temperature detectors (RTDs)
The resistance of most metals increases, over a limited temperature range, in a
reasonably linear way with temperature (Fig.).
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
25 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Variation of Resistance with temperature for metals
For such a linear relationship:
Rt = Ro (l + αt)
where Rt is the resistance at a temperature t0 C, Ro the resistance at 0°C and α a constant
for the metal termed the temperature coefficient of resistance. Resistance temperature
detectors (RTDs) are simple resistive elements in the form of coils of wire of such metals
as platinum, nickel or nickel-copper alloys; platinum is the most widely used. Thin film
platinum elements are often made by depositing the metal on a suitable substrate, wire-
wound elements involving a platinum wire held by a high temperature glass adhesive
inside a ceramic tube. Such detectors are highly stable and give reproducible responses
over long periods of time. They tend to have response times of the order of 0.5 to 5 s or
more.
3. Thermistors
Thermistors are small pieces of material made from mixtures of metal oxides,
such as those of chromium, cobalt, iron, manganese and nickel. These oxides are
semiconductors. The material is formed into various forms of element, such as beads,
discs and rods (in Fig.).
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
26 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Thermistor
The resistance of conventional metal-oxide thermistors decreases in a very non-
linear manner with an increase in temperature, as illustrated in Figure.
Fig : Variation of Resistance with temperature for a typical thermistor
Such thermistors having negative temperature coefficients (NTC). Positive
temperature coefficient (PTC) thermistors are, however, available. The change in
resistance per degree change in temperature is considerably larger than that which
occurs with metals. The resistance-temperature relationship for a thermistor can be
described by an equation of the form
β/tt eK R =
where Rt is the resistance at temperature t, with K and β being constants. Thermistors
have many advantages when compared with other temperature sensors. They are
rugged and can be very small, so enabling temperatures to be monitored at virtually a
point. Because of their small size they respond very rapidly to changes in temperature.
They give very large changes in resistance per degree change in temperature. Their
main disadvantage is their non-linearity.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
27 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
INPUTTING DATA BY SWITCHES
Mechanical switches consist of one or more pairs of contacts which can be
mechanically closed or opened and in doing so make or break electrical circuits. Thus 0
or 1 signals can be transmitted by the act of opening or closing a switch.
Mechanical switches are specified in terms of their number of poles and throws.
Poles are the number of separate circuits that can be completed by the same switching
action and throws are the number of individual contacts for each pole. Figure (a) shows
a single pole-single throw (SPST) switch, Figure (b) a single pole-double throw (DPDT)
switch and Figure (c) a double pole-double throw (DPDT) switch.
Fig : Switches (a) SPST, (b) SPDT, (c) DPDT
1. Debouncing
A problem that occurs with mechanical switches is switch bounce. When a
mechanical switch is switched to close the contacts, we have one contact being moved
towards the other. It hits the other and, because the contacting elements are elastic,
bounces. It may bounce a number of times (Fig.) before finally settling to its closed state
after, typically, some 20 ms. Each of the contacts during this bouncing time can register
as a separate contact. Thus, to a microprocessor, it might appear that perhaps two or
more separate switch actions have occurred. Similarly, when a mechanical switch is
opened, bouncing can occur. To overcome this problem either hardware or software
can be used.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
28 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Switch bounce on closing
With software, the microprocessor is programmed to detect if the switch is
closed and then wait, say, 20 ms. After checking that bouncing has ceased and the
switch is in the same closed position, the next part of the program can take place. The
hardware solution to the bounce problem is based on the use of a flip-flop. Figure
shows a circuit for debouncing a SPDT switch which is based on the use of a SR flip-
flop.
Fig : Debouncing a SPDT switch
As shown, we have S at 0 and R at 1 with an output of 0. When the switch is
moved to its lower position, initially S becomes 1 and R becomes 0. This gives an
output of 1. Bouncing in changing S from 1 to 0 to 1 to 0, etc. gives no change in the
output. Such a flip-flop can be derived from two NOR or two NAND gates. A SPDT
switch can be debounced by the use of a D flip-flop. The output from such a flip-flop
only changes when the clock signal changes. Thus by choosing a clock period which is
greater than the time for which the bounces last, say 20 ms, the bounce signals will be
ignored.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
29 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
SIGNAL CONDITIONING
The output signal from the sensors of a measurement system has generally to be
processed in some way to make it suitable for the next stage of the operation. The signal
may be, for e.g., too small and have to be amplified, contain interference which has to
be removed, be non-linear and require linearization, be analogue and have to be made
digital, be digital and have to be made analogue, be a resistance change and have to be
made into a current change, be a voltage change and have to be made into a suitable
size current change, etc. All these changes can be referred to as signal conditioning. For
example, the output from a thermocouple is a small voltage, a few millivolts. A signal
conditioning module might then be used to convert this into a suitable size current
signal, provide noise rejection, linearization, and cold junction compensation (i.e.
compensating for the cold junction not being at 00C).
The signal handled by microprocessors need to be conditioned for effective
processing. The signals from the sensors/transducers may be non linear, noise filled or
weak in magnitude. Such signals should be modified and magnified to suit the
specification rating of the microprocessor and micro controllers. There may be need to
convert the signal from one form to another. These signal conditioning functions are
most commonly, done using operational amplifiers of various types. The
microprocessors are to be protected from excessive voltage and reverse polarity of the
signal proper electronic protection circuit. The signal conditioning and protection are
accomplished by the interface systems inserted between sensors/actuators and the
microprocessors.
Certain parameters like speed, position, force etc., are sensed before
measurement, to give some form of signal to be processed. Such signal before being
input to the next stage of processing may have to be conditioned for under lying
reasons.
The signal can be weak and has to be magnified.
It may have interface as a noise which is to be filtered.
The non-linear signal has to be manipulated.
The signal may have to be converted for the change in resistance and voltage.
Analogue form may be required in the digital form.
The digital form may need conversion to analogue form.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
30 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Hence the signal which may be weak, non-linear, noise filled, and certain form is
transformed to an amplified signal, linear, noise free and some other required form
through an amplifier, signal manipulator, a filter and a converter before being supplied
to a processor is known as “signal conditioning”.
CONCEPT OF SIGNAL CONDITIONING
Fig : Signal conditioning concept
INTERFACING WITH A MICROPROCESSOR
Input and output devices are connected to a microprocessor system through
ports. The term interface is used for the item that is used to make connections between
devices and a port. Thus there could be inputs from sensors, switches and keyboards
and output to displays and actuators. The simplest interface could be just a piece of
wire. However, the interface often contains signal conditioning and protection, the
protection being to prevent damage to the microprocessor system. For example inputs
needing to be protected against excessive voltages or signals of the wrong polarity.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
31 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Microprocessor requires input s which are digital, thus a conversion of analogue
to digital signal is necessary if the output from a sensor is analogue. However, many
sensors generates only a very small signal, perhaps a few mill volts. Such a signal is
insufficient to be directly converted from analogue to digital without first being
amplified. Signal conditioning might also be needed with digital signals to improve
their quality. The interface may thus contain a number of elements.
There is also the output from a microprocessor, perhaps to operate an actuator. A
suitable interface is also required here. The actuator might require an analogue signal
and so the digital output from the microprocessor needs converting to an analogue
signal. There can also be a need for protection to stop any signal becoming inputted
back through the output port to damage the microprocessor.
NEED FOR SIGNAL CONDITIONING
The signal required by the microprocessor or the microcontroller cannot be in the
raw form from the input devices like sensors. The signals need transformation which is
accomplished by the interface systems, connected between input devices and
processors, and processor and output devices. The need for conditioning signal arises
for the following aspects:
The processor is to be protected from the erratic input signals of excessive
voltage and wrong polarity.
The protection from the sudden output signal.
The processor can process the signal that is in the compatible form with the
system characteristics.
The processing system can receive the signals that have ratings suitable to their
specifications.
The processors are capable of handling noise free and disturbance free signals to
perform correctly.
The non-linearity in the signals output from the input devices needed to be
manipulated to transform into linear signals.
The interface systems between input devices like sensors switches, keyboards,
and the microprocessors is first being amplified, then being converted from analogue
form to digital form and then protected for excessive voltage and wrong polarity.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
32 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
OPERATIONAL AMPLIFIERS
The Operational Amplifier is a high gain d.c. amplifier, the gain typically being of
the order of 100, 000 or more, that is supplied as an integrated circuit on a silicon chip.
By definition, operational amplifier is a high gain d.c. device that magnifies the input
signal (current or voltage) up to an order of 106 or more. It is supplied as a silicon chip
with integrated circuit in it. A typical chip with op-amp is shown in fig.
The op-amp has mainly two inputs, known as the inverting input (-) and the
non-inverting input (+). The types of inputs to an operational amplifier are:
1. Negative inverting input
2. Positive non-inverting input
3. Negative voltage supply
4. Positive voltage supply
5. Two offset null inputs for extracting non-ideal behaviors from op-amps.
Fig : Operational Amplifier
Depending on the inputs and connections of impedance, the op-amps perform as:
• Voltage to current or current to voltage converter
• The signal adder
• Signal magnifier
• Non-linear to linear manipulator
• A filter for noise reduction
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
33 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
1. INVERTING AMPLIFIER
The input is taken to the inverting input through a resistor R1 with the non-
inverting input being connected to ground. A feedback path is provided from the
output, via the resistor R2 to the inverting input. The operational amplifier has a voltage
gain of about 100 000 and the change in out put voltage is limited to about V 10_+ . The
input voltage then must be between +0.0001 V and -0.0001 V. This is virtually zero and
so point X is at virtually earth potential. For this reason it is called a virtual earth. The
potential difference across R1 is (Vin -Vx). Hence, for an ideal operational amplifier with
an infinite gain, and hence Vx = 0, the input potential Vin can be considered to be across
R1.
12in R I V Thus =
Fig: Inverting amplifier
The operational amplifier has very high impedance between its input terminals;
for a 741 about 2 MΩ. Thus virtually no current flows through X into it. For an ideal
operational amplifier the input impedance is taken to be infinite and so there is no
current flow through X. Hence the current I1 through R1 must be the current through R2.
The potential difference across R2 is (Vx - Vout) and thus, since Vx is zero for the ideal
amplifier, the potential difference across R2 is –Vout.
22out R I V- Thus =
Dividing these two equations:
1
2
in
out
R
R- =
V
V =circuit ofgain Voltage
Thus the voltage gain is determined solely by the relative values of R1 and R2. The
negative sign indicates that the output is inverted, i.e. 1800 out of phase, with respect to
the input.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
34 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2. NON-INVERTING AMPLIFIER
The output can be considered to be taken from across a potential divider circuit
consisting of R1 in series with R2. The voltage Vx is then the fraction R1/ (R1+R2) of the
output voltage.
V )R+(R
R =Vx out
21
1
Since there is virtually no current through the operational amplifier between the two
inputs there can be virtually no potential difference between them. Thus, with the ideal
operational amplifier, we must have Vx =Vin. Hence
1
2
1
21
in
out
R
R+1 =
R
)R+(R =
V
V =circuit ofgain Voltage
Fig : Non- inverting amplifier
3. SUMMING AMPLIFIER
As with the inverting amplifier, X is a virtual earth. Thus the sum of the currents
entering X must equal that leaving it. Hence
CBA I I I I ++=
But IA = VA/RA, IB = VB/RB and IC = VC/RC. Also we must have the same current I passing
through the feedback resistor. The potential difference across R2 is (VX – Vout). Hence,
since Vx can be assumed to be zero, it is –Vout and so I = -Vout/R2. Thus
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
35 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
C
C
B
B
A
A
2
out
R
V +
R
V +
R
V =
R
V -
The output is thus the scaled sum of the inputs, i.e.
c
c
2B
B
2A
A
2out V
R
R + V
R
R + V
R
R- = V
If RA= RB=RC=R1 then
)V+V+(V R
R- = V CBA
2
1out
Fig : Summing amplifier
FILTERING
The term filtering is used to describe the process of removing a certain band of
frequencies from a signal and permitting others to be transmitted. The range of
frequencies passed by a filter is known as the pass band, the range not passed as the stop
band and the boundary between stopping and passing as the cut-off frequency. Filters are
classified according to the frequency ranges they transmit or reject.
A low-pass filter has a pass band which allows all frequencies from 0 up to some
frequency to be transmitted.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
36 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Characteristics of ideal low pass filter
A high pass filter has a pass band which allows all frequencies from some value
up to infinity to be transmitted.
Fig : Characteristics of ideal high pass filter
A band pass filter allows all the frequencies within a specified band to be
transmitted.
Fig : Characteristics of ideal band pass filter
A band stop filter stops all frequencies with a particular band from being
transmitted.
Fig : Characteristics of ideal band stop filter
In all cases the cut-off frequency is defined as being that at which the output
voltage is 70.7% of that in the past band. The term attenuation is used for the ratio of
input and output powers, this being written as the ratio of the logathirm of the ratio and
so gives the attenuation in units of bels. Since this is a rather large unit, decibels (dB) are
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
37 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
used and then attenuation in dB = 10 lg (input power /output power). Since the power
through an impedance is proportional to the square of the voltage the attenuation in
dB = 20 1g (input voltage /output voltage). The output voltage of 70.7% of that in the
pass band is thus an attenuation of 3dB.
The term passive is used to describe a filter made up using only resistors,
capacitors and inductors, the term active being used when the filter also involves an
operational amplifier. Passive filters have the disadvantage that the current that is
drawn by the item that follows can change the frequency characteristics of the filter.
This problem does not occur with an active filter.
Low-pass filters are very commonly used as a part of signal conditioning. This is
because most of the useful information being transmitted is low frequency. Since noise
tends to occur at higher frequencies, a low-pass filter can be used to block it off. Thus a
low-pass filter might be selected with a cut-off frequency of 40 Hz, thus blocking off any
inference signals from the A.C mains supply and noise in general.
Low pass passive filters are characterized to operate in the lower frequencies and
are generally used to filter the noise occurring in the higher frequencies as in case of
interferences in an a.c. mains supply. They are termed passive because they make use of
only resistors, inductors and capacitors to make the filters.
Fig : Low-pass passive filter
Low pass active filters: An integrating operational amplifier using a capacitor in its
feedback loop acts as a low pass active filter that removes noise in the high frequency
range. Figure shows the basic form of low pass filter.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
38 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Low-pass active filter
High pass passive filters: Passive high pass filter that filters the noises at lower
frequencies and transmits of higher frequencies is shown in figure. Two capacitors
arranged in series between input and output with a parallel inductor functions as high
pass passive filter.
Fig : Passive high pass filter
A high pass active filter using operational amplifier is shown in fig. The feedback
output is given to both inverting and non-inverting inputs through a resistor. Two
capacitors in series with inverting input do the filtering of noise at high frequencies.
Fig : High pass active filter
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
39 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MULTIPLEXERS
There are situations common in practical circuits that a processor has to receive
and process in sequence the data from multiple sources. A multiplexer is a circuit that is
able to have inputs of data from a number of sources and then, by selecting an input
channel, give an output from just one of them. The multiplexer enables to share single
data channel between multiple input sources. In applications where there is need for
measurements to be made at a number of different locations, rather than use a separate
ADC and microprocessor for each measurement, a multiplexer can be used to select
each input in turn and switch it through a single ADC and microprocessor. The
multiplexer is essentially an electronic switching device enables each of the inputs to be
sampled in turn.
Fig : Multiplexer
There are two types of multiplexers:
Time Division Multiplexing (TDM)
Frequency Division Multiplexing (FDM)
1. In Time Division Multiplexing (TDM), each of the data sources is connected to data
channel transmitting the data. In this the data is made available to the processor at
different time. Often there is a need for a number of peripheral devices to share the
same input/output lines from a microprocessor. So that each peripheral can be
supplied with different data it is necessary to allocate each a particular time slot
during which data is transmitted. This is termed time division multiplexing. When
large data slowly varying with time TDM is useful. The examples of data source for
measurement are pressure, temperature and static strain. These data have discrete
values in series useful to TDM. Figure shows the time division multiplexing.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
40 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : TDM concept
2. The Frequency Division Multiplexer (FDM) is particularly suited for analogue signals.
In this each data source is modulated to subcarrier frequency. All the subcarriers
are combined in a mixer and modulated to higher frequency carriers. Then the
information is transmitted to the receiver. Receiver after demodulation separates
into such carriers and filtered to contain the individual information data. This uses
both amplitude modulation systems. A block diagram of operation of FDM is
shown in figure.
Fig : FDM concept
DATA ACQUISITION
- -
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
41 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : DAQ System
- -
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
42 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
DATA ACQUISITION SYSTEMS
Automated data acquisition systems can take the form of a dedicated instrument
termed a data logger or a personal computer using plug-in DAQ boards.
Data loggers
Figure shows the basic elements of a data logger. Such a unit can monitor the
inputs from a large number of sensors. Inputs from individual sensors, after suitable
signal conditioning, are fed into the multiplexer. The multiplexer is used to select one
signal which is then fed, after amplification, to the analogue-to-digital convertor. The
digital signal is then processed by a microprocessor. The microprocessor is able to carry
out simple arithmetic operations, perhaps taking average of a number of measurements.
The output from the system might be displayed on a digital meter that indicates the
output and channel number, used to give a permanent record with a printer, stored on a
floppy disc or transferred to perhaps a computer for analysis.
Fig : Data logger system
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
43 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PULSE MODULATION
A problem that is often encountered with dealing with the transmission of low-
level d.c. signals from sensors is that the gain of an operational amplifier used to
amplify them may drift and so the output drifts. This problem can be overcome if the
signal is a sequence of pulses rather than a continuous-time signal.
One way this conversion can be achieved is by chopping the d.c. signal in the
way suggested in fig. The output from the chopper is a chain of pulses, the heights of
which are related to the d.c. level of the input signal. This process is called pulse
amplitude modulation. After amplification and any other signal conditioning, the
modulated signal can be demodulated to give a d.c. output. With pulse amplitude
modulation, the height of the pulses is related to the size of the d.c. voltage.
Fig : Pulse Amplitude Modulation
An alternative to this is pulse width modulation (PWM) where the width, i.e.
duration, of a pulse rather than its amplitude depends on the size of the voltage.
Fig : Pulse Width Modulation
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
44 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
DISPLAYS
Measurement systems consist of three elements: sensor, signal conditioner and
display or data presentation element. There are a very wide range of elements that can
be used for the presentation of data. Traditionally they have been classified into two
groups: indicators and recorders. Indicators give an instant visual indication of the
sensed variable while recorders record the output signal over a period of time and give
automatically a permanent record. The recorder will be the most appropriate choice if
the event is high speed or transient and cannot be followed by an observer, or there are
large amounts of data, or it is essential to have a record of the data.
Both indicators and recorders can be subdivided into two groups of devices,
analogue and digital. An example of an analogue indicator is a meter which has a pointer
moving across a scale, while a digital meter would be just a display of a series of
numbers. An example of an analogue recorder is a chart recorder which has a pen
moving across a moving sheet of paper, while a digital recorder has the output printed
out on a sheet of paper as a sequence of numbers.
Data Presentation Elements
The most commonly used examples of data presentation elements are
1. Analogue and digital meters
The moving coil meter is an analogue indicator with a pointer moving across a
scale. The basic instrument movement is a d.c. micro ammeter with shunts, multipliers
and rectifiers being used to convert it to other ranges of direct current and measurement
of alternating current, direct voltage, and alternating voltage. With alternating current
and voltages, the instrument is restricted to between about 50 Hz and 10 kHz. The
accuracy of such a meter depends on a number of factors, among which are
temperatures, the presence of nearby of magnetic fields or ferrous materials, the way
the meter is mounted, bearing friction, inaccuracies in scale marking during
manufacture, etc. In addition there are errors involved in reading the meter, e.g.
parallax errors when the position of the pointer against the scale is read from an angle
other than directly at right angles to the scale and errors arising from estimating the
position of the pointer between scale markings. The overall accuracy is generally of the
order of ± 0.1 to ± 5%. The time taken for a moving coil meter to reach a steady
deflection is typically in the region of a few seconds. The low resistance of the meter can
present loading problems.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
45 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The digital voltmeter gives its reading in the form of a sequence of digits. Such a
form of display eliminates parallax and interpolation errors and can give accuracies as
high as ± 0.005%. The digital voltmeter is essentially just a sample and hold unit feeding
an analogue-to-digital converter with its output counted by a counter (in fig.).
Fig : Principle of digital voltmeter
It has a high resistance, of the order of 10 MΩ, and so loading effects are less
likely than with the moving coil meter with its lower resistance. Thus, if a digital
voltmeter specification includes the statement ‘sample rate approximately 5 readings
per second’ then this means that every 0.2 s the input voltage is sampled. It is the time
taken for the instrument to process the signal and give a reading. Thus, if the input
voltage is changing at a rate which results in significant changes during 0.2 s then the
voltmeter reading can be in error. A low cost digital voltmeter has typically a sample
rate of 3 per second and an input impedance of 100 MΩ.
2. Analogue chart recorders
There are three basic types of analogue chart recorders: the direct reading
recorder, the galvanometric recorder and the potentiometric or closed-loop recorder.
The data can be recorded on paper by fibre-tipped ink pens, by the impact of a pointer
pressing a carbon ribbon against the paper, by the use of thermally sensitive paper
which changes color when a heated pointer moves across it, by a beam of ultraviolet
light falling on paper sensitive to it and by a tungsten wire stylus moving across the
surface of specially coated paper, a thin layer of aluminium over coloured dye, and the
electrical discharge removing the aluminium and exposing the dye.
The direct reading recorder (in Fig.) has a pen or stylus directly moved by the
displacement action of the measurement system. For temperature measurement this
might be the displacement of a bimetallic strip, for a pressure gauge the displacement of
a Bourdon tube. A circular chart is used and rotates at a constant rate, typically one
revolution in 12 hours, 24 hours or 7 days. The pen moves along curved radial lines and
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
46 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
thus paper with curved lines has to be used for the plotting. This makes interpolation
difficult. Simultaneous recording with up to four separate variables is possible with
four separate pens. The instrument is fairly robust with accuracy of the order of ± 0.5%
of the full-scale deflection.
Fig : Direct reading recorder
The galvanometric type of chart recorder (Fig.) works on the same principle as the
moving coil meter movement. The coil is suspended between two fixed points by a
suspension wire. When a current passes through the coil a torque acts on it, causing it to
rotate and twist the suspension. The coil rotates to an angle at which the torque is
balanced by the opposing torque resulting from the twisting of the suspension. The
rotation of the coil results in a pen being moved across a chart.
If R is the length of the pointer and θ the angular deflection of the coil, then the
displacement y of the pen is y = R sin θ. Since θ is proportional to the current i through
the coil, then y is proportional to sin i. This is a non-linear relationship. However, if the
angular deflections are restricted to less than ±100, then the relationship is reasonably
linear, the non-linearity error being less than 0.5%. A greater problem is, however, the
fact that the pen moves in an arc rather than a straight line and thus curvilinear paper
(Fig.) has to be used for the plotting. With such forms of chart there are difficulties in
interpolation for points between the lines.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
47 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Galvanometric recorder
3. Printers
Printers provide a record of data on paper. There are a number of versions of
such printers: the dot matrix printer, the ink/bubble jet printer and the laser printer.
The dot matrix printer has a print head (Fig.) which consists of either 9 or 24 pins
in a vertical line. Each pin is controlled by an electromagnet which when turned on
propels the pin onto the inking ribbon. This transfers a small blob of ink onto the paper
behind the ribbon. A character is formed by moving the print head in horizontal lines
back-and-forth across the paper and firing the appropriate pins.
Fig : Dot matrix print head mechanism
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
48 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The ink jet printer uses a conductive ink which is forced through a small nozzle to
produce a jet of very small drops of ink of constant diameter at a constant frequency.
With one form a constant stream of ink passes along a tube and is pulsed to form fine
drops by a piezoelectric crystal which vibrates at a frequency of about 100 kHz (in fig.).
Fig : Producing a stream of drops
Another form uses a small heater in the print head with vaporized ink in a
capillary tube, so producing gas bubbles which push out drops of ink (shown in figure
given below).
Fig : Principle of the bubble jet
In one printer version each drop of ink is given a charge as a result of passing
through a charging electrode and the charged drops are deflected by passing between
plates between which an electric field is maintained; in another version a vertical stack
of nozzles is used and each jet is just switched on or off on demand. Inkjet printers can
give colour prints by the use of three different colour ink jet systems. The fineness of the
drops is such that prints can be produced with more than 600 dots per inch.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
49 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MEASUREMENT SYSTEMS
The following examples illustrate some of the points involved in the design of
measurement systems for particular applications.
1. Load cell for use as a link to detect load lifted
A link-type load cell has four strain gauges attached to its surface and can be
inserted in between the cable lifting a load and the load to give a measure of the load
being lifted. Two of the strain gauges are in the longitudinal axis direction and two in a
transverse direction. When the link is subject to tensile forces, the axial gauges will be in
tension and the transverse gauges in compression. Suppose we have the design criteria
for the load cell of sensitivity such that there is an output of about 30 mV when the
stress applied to the link is 500 MPa. We will assume the strain gauges may be assumed
to have gauge factor of 2.0 and resistance of 100Ω.
Fig : Load cell
When a load F is applied to the link then, since the elastic modulus E is
stress/strain and stress is force per unit area, the longitudinal axis strain εl is F/AE and
the transverse strain εt is –υF/AE, where A is the cross-sectional area and υ is Poisson’s
ratio for the link material.
The responses of the strain gauges to the strain are
AE
GF - =G =
R2
R2 =
R3
R3
AE
GF= G =
R4
R4 =
R1
R1
2
1
νε
δδ
εδδ
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
50 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The output voltage from the Wheatstone bridge is given by
4
4
3
3
2
2
1
1
4321
41so
R
R +
R
R -
R
R -
R
R
)R+(R )R+(R
R R V = V
δδδδ
With R1 = R2 = R3 = R4 = R, and with δR1 = δR4 and δR2 = δR3,
( )
( )ν
δδ
+=
−=
12AE
GF V
R R 2R
V V then
s
21s
o
2. Temperature alarm system
A measurement system is required which will set off an alarm when the
temperature of the liquid rises above 400 C. The liquid is normally at 300 C. The output
from the system must be a 1V signal to operate the alarm.
Since the output is to be electrical and the reasonable speed of response is likely
to be required, an obvious possibility is an electrical response element. To generate a
voltage output the resistance element could be used with a Wheatstone bridge .The
output voltage will probably be less than 1V for a change from 30 to 400 C but a
differential amplifier could be used to enable the required voltage to be obtained. A
comparator can then be used to compare the value with the set of value for the alarm.
Suppose a nickel element is used. Nickel has a temperature of coefficient of
resistance of 0.0067 /K. Thus if the resistance element is taken as being 100 Ω at 00 C
then its resistance at 300 C will be
Ω 120.1 30) 0.0067 (1 100 at) (1 R R 030 =×+=+=
and at 400 C
Ω 126.8 40) 0.0067 (1 100 R 40 =×+=
Thus there is a change in resistance of 6.7 Ω. If this element forms one arm of a
Whetstone bridge which is balanced at 300 C, then the output voltage V0 is given by
21
1so
RR
R V V
+=
δδ
With the bridge balanced at 300 C and, say, all the arms the same value and a supply
voltage at 4 V, then
0.109 120.1 126.8
6.7 X 4 V o =
+=δ
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
51 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
CALIBRATION
Calibration consists of comparing the output of a measurement system and its
sub systems against standards of known accuracy. The standards may be other
instruments which are kept specially for calibration duties or some means of defining
standard values. The relationship between the calibration of an instrument in everyday
use and national standards is likely to be:
1. National standards are used to calibrate standards for calibration centers.
2. Calibration centre standards are used to calibrate standards for instrument
manufacturers.
3. Standardized instruments from instrument manufacturers are used to provide
in-company standards.
4. In-company standards are used to calibrate process instruments.
The following are some examples of calibration procedures that must be used in-
company:
1. Voltmeters : These can be checked against standard voltmeters or standard cells
giving standard e.m.f.s.
2. Ammeters : These can be checked against standard ammeters.
3. Gauge factor of strain gauges : This can be checked by taking a sample of gauges
from a batch and applying measured strains to them when mounted on some test
piece. The resistance changes can be measured and hence the gauge factor
computed.
4. Wheat stone bridge circuits : The output from a wheat stone bridge can be checked
when a standard resistance is introduced into one of the arms.
5. Load cells : For low-capacity load cells, dead-weight loads using standard weights
can be used.
6. Pressure sensors : Pressure sensors can be calibrated by using a dead-weight tester.
The calibration pressures are generated by adding standard weights W to the piston
tray. After the weights are placed on the tray, a screw-driven plunger is forced into
the hydraulic oil in the chamber to lift the piston weight assembly. The calibration
pressure is then W/A, where A is the cross-sectional area of the piston. Alternatively
the dead-weight tester can be used to calibrate a pressure gauge and this gauge can
be used for the calibration of other gauges.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
52 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PNEUMATIC AND HYDRAULIC ACTUATION SYSTEMS
Pneumatic signals are often used to control final control elements, even when the
control system is otherwise electrical. This is because such systems can be used to
actuate large valves and other high power control devices and so move significant
loads. The main drawback with pneumatic systems is, however, the compressibility of
air. Hydraulic signals can be used for even higher power control devices but are more
expensive than pneumatic systems and there are hazards associated with oil leaks
which do not occur with air leaks.
Power supplies
With a hydraulic system, pressurized oil is provided by a pump driven by an
electric motor. The pump pumps oil from a sump through a non-return valve and an
accumulator to the system, from which it returns to the sump. Figure illustrates the
arrangement.
Fig : Hydraulic power supply
A pressure relief valve is included, this being to release the pressure if it rises
above a safe level, the non-return valve is to prevent the oil being back driven to the
pump and the accumulator is to smooth out any short-term fluctuations in the output
oil pressure. Essentially the accumulator is just a container in which the oil is held
under pressure against an external force, figure showing the most commonly used form
which is gas pressurized and involves gas within a bladder in the chamber containing
the hydraulic fluid, an older type involved a spring-loaded piston. If the oil pressure
rises then the bladder contracts, increases the volume the oil can occupy and so reduces
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
53 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
the pressure. If the oil pressure falls, the bladder expands to reduce the volume
occupied by the oil and so increase its pressure.
Fig : Accumulator
With a pneumatic power supply (in fig.) an electric motor drives an air
compressor. The air inlet to the compressor is likely to be filtered and via a silencer to
reduce the noise level. A pressure relief valve provides protection against pressure in
the system rising above a safe level. Since the air compressor increases the temperature
of the air there is likely to be a cooling system and to remove contamination and water
from the air a filter with water trap. An air receiver increases the volume of air in the
system and smoothes out any short-term pressure fluctuations.
Fig : Pneumatic power supply
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
54 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
VALVES
To affect various functions in a hydraulic power pack to control the operations of
the actuators the hydraulic valves are used. The following subjective aspects are needed
to be controlled in the hydraulic circuits according to the application requirements.
§ The pressure control.
§ The flow control.
§ The direction control.
The system pressure should not exceed certain limit for the safety of the pump.
The different branches in the circuit need different pressure in the hydraulic oil
supplied to the actuators. The pressure should be retained in certain actuator function
without exhibiting drift in the position. The actuators are to be sequenced by pressure
control to operate in a required order. The relief, regulation, balancing and sequencing
are the pressure control aspects carried out by pressure control valves.
The amount of oil specified by volumetric flow rate reaching the actuator is
regulated by the flow control valves. For an actuator of given geometrical configuration
the speed of actuation has a direct bearing on the rate of flow of oil. The position of flow
control valve in different segment of the circuit executes different flow control action
needed for the suitable application.
The actuators (linear or rotary) are to be reversed in operation or stopped at
certain stage for idling. The reversal in direction is effected by the direction control
valves. Different aspects and duty, different configurations in directional valve exist.
DIRECTIONAL CONTROL VALVES
Pneumatic and hydraulic systems use directional control valves to direct the flow
of fluid through a system. They are not intended to vary the rate of flow of fluid, but are
either completely open or completely closed, i.e. on/off devices. Such on/off valves are
widely used to develop sequenced control systems. They might be activated to switch
the fluid flow direction by means of mechanical, electrical or fluid pressure signals.
A common type of directional control valve is the spool valve. A spool moves
horizontally within the valve body to control the flow. The fig shows a particular form.
In (a), the air supply is connected to port 1 and port 3 is closed. Thus the device
connected to port 2 can be pressurized. When the pool is moved to the left, as in (b), the
air supply is cut off and port 2 is connected to port 3. Port 3 is a vent to the atmosphere
and so the air pressure in the system attached to port 2 is vented. Thus the movement of
the spool has allowed the air to firstly flow into the system and then be reversed and
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
55 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
flow out of the system. Rotary spool valves have a rotating spool which, when it rotates,
opens and closes ports in a similar way.
Fig : Spool Valve
Another common form of directional control valve is the poppet valve. The
figure shows 1 form. This valve is normally in the closed condition, there being no
connection between port1 to which the pressure supply is connected and port 2 to
which the system is connected. In poppet valves, balls, discs or cones are used in
conjunction with valve seats to control the flow. When the push button is depressed, the
ball is pushed out of its seat and flow occurs as a result of port 1 being connected to port
2. When the button is released, the spring forces the ball back up against its seat & so
closes off the flow.
Fig : Poppet Valve
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
56 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
ACTUATORS
Actuation systems are the elements of control systems, which are responsible for
transforming the output, of a microprocessor or control system into a controlling action
on a machine or a device. Thus, or e.g., we might have an electrical output from the
controller which has to be transformed into a linear motion to move a lode. Another e.g.
might be where an electrical output from the controller has to be transformed into an
action which controls the amount of liquid passing along a pipe.
DEFINITION OF ACTUATOR AND ACTUATOR SYSTEM
Any mechanical, electrical or electro mechanical system that produces linear or
rotary motion to drive mechanical events like shafts, screws, slide or a manipulator
can be termed as actuator.
Along with the actuator other elements like connecting parts, fixtures,
attachments and hardware that serve the purpose of generation of motion either linear
or rotational can be termed as actuator system.
Examples. A hydraulic cylinder with connecting yoke or clevis and mounting flange
or trunnion can be treated as actuator system.
An electrical motor with output shaft provided with key or flanged coupling
and mounting plate, forms an actuator system.
The purpose of actuator is to convert one form of energy into mechanical work
in the form of motion. The energy comes in the form of electrical energy or mechanical
energy. Electrical conductors are the transfer elements for the electrical energy. The
hydraulic oil or air is the medium to carry the mechanical energy. The actuator that
works on the pressure energy supplied by the hydraulic oil is called the "Hydraulic
Actuator".
CLASSIFICATION OF ACTUATORS
The first level of classification is based on the type of motion produced by an
actuator, i.e., linear or rotational. In the next level of classification the type of energy and
the energy medium is taken as the basis. In the third level the configuration of design
forms the basis of classification.
In the first level of classification the type of motion bifercates the actuators into
linear and rotary actuators. Translation is the function of linear actuators where as
rotation is the function of rotary actuators. Sometimes the rotatory actuators with the
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
57 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
aid of mechanical elements produce translatory motion in the mechatronic system. In
some mechanical systems the reciprocatory motion is converted to rotary motion by
cranking action. The output of translation is the displacement and force exertion. The
rotary actuation results in the output of angular displacement and torque. Both type of
actuations are responsible for some form of power development that can do work.
The types of medium conveying energy to the actuating system further classify
each actuator in this level. The electrical energy is most commonly used form of energy
that directly and indirectly assists the function of actuation. The pressurized hydraulic
oil and compressed air are other kinds of media that help in carrying energy to the
hydraulic and pneumatic actuators. It is the electrical energy that is used to create the
pressure in hydraulic and pneumatic media.
The third level of classification has the design configurations as the basis. The
functional requirements, the output specifications, the characteristic performance
indicators are taken as the base to configure various designs. This base of classification
is application dependent. The style, the manufacturing considerations, cost
considerations, the reliability consideration and size consideration form the basis.
Fig : Tree diagram of classification of actuators
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
58 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MECHANICAL ACTUATION SYSTEMS
These are consideration of mechanisms; mechanisms are devices which can be
considered to be motion converters in that they transform motion from one form to
some other required form. They might, for example, transform linear motion into
rotational motion, or motion in one direction into a motion in a direction at right angles,
or perhaps a linear reciprocating motion into rotary motion, as in the internal
combustion engine where the reciprocating motion of the pistons is converted into
rotation of the crank and hence the drive shaft.
Mechanical elements can include the use of linkages, cams, gears, rack-and-
pinion, chains, belt drives, etc. For example, the rack-and-pinion can be used to convert
rotational motion to linear motion. Parallel shaft gears might be used to reduce a shaft
speed. Bevel gears might be used for the transmission of rotary motion through 90°. A
toothed belt or chain drive might be used to transform rotary motion about one axis to
motion about another. Cams and linkages can be used to obtain motions which are
prescribed to vary in a particular manner.
Many of the actions which previously were obtained by the use of mechanisms
are, however, often nowadays being obtained by the use of microprocessor systems. For
example, cams on a rotating shaft were previously used for domestic washing machines
in order to give a timed sequence of actions such as opening a valve to let water into the
drum, switching the water off, switching a heater on, etc. Modern washing machines
use a microprocessor-based system with the microprocessor programmed to switch on
outputs in the required sequence.
Mechanisms still, however, have a role in mechatronics systems. For example,
the mechatronics system in use in an automatic camera for adjusting the aperture for
correct exposures involves a mechanism for adjusting the size of the diaphragm. While
electronics might now be used often for many functions that previously were fulfilled
by mechanisms, mechanisms might still be used to provide such functions as:
1. Force amplification, e.g. that given by levers.
2. Change of speed, e.g. that given by gears.
3. Transfer of rotation about one axis to rotation about another. e.g. a timing belt.
4. Particular types of motion, e.g. that given by a quick-return mechanism.
The term kinematics is used for the study of motion without regard to forces.
When we consider just the motions without any consideration of the forces or energy
involved then we are carrying out a kinematic analysis of the mechanism.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
59 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
FREEDOM AND CONSTRAINTS
An important aspect in the design of mechanical elements is the orientation and
arrangement of the elements and parts. A body that is free in space can move in three,
independent, mutually perpendicular directions and rotate in three ways about those
directions (Fig.). It is said to have six degrees of freedom.
Fig: Types of motion
The number of degrees of freedom is the number of components of motion that are
required in order to generate the motion. If a joint is constrained to move along a line then
its translational degrees of freedom are reduced to one. Figure (a) shows a joint with just
this one translational degree of freedom. If a joint is constrained to move on a plane
then it has two translational degrees of freedom. Figure (b) shows a joint which has one
translational degree of freedom and one rotational degree of freedom.
Fig: Joints with: (a) one, (b) two degrees of freedom
GEAR TRAINS
Gear trains are mechanisms which are very widely used to transfer and transform
rotational motion. They are used when a change in speed or torque of a rotating device is
needed. For example, the car gearbox enables the driver to match the speed and torque
requirements of the terrain with the engine power available.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
60 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Rotary motion can be transferred from one shaft to another by a pair of rolling
cylinders (Fig.); however, there is a possibility of slip. The transfer of the motion between
the two cylinders depends on the frictional forces between the two surfaces in contact. Slip
can be prevented by the addition of meshing teeth to the two cylinders and the result is then
a pair of meshed gear wheels.
Fig: Rolling Cylinders
Gears can be used for the transmission of rotary motion between parallel shafts and
for shafts which have axes inclined to one another.
RATCHET AND PAWL
Ratchets can be used to lock a mechanism when it is holding a load. Figure shows a
ratchet and pawl. The mechanism consists of a wheel, called a ratchet, with saw-shaped teeth
which engage with an arm called a pawl. The arm is pivoted and can move back and forth to
engage the wheel. The shape of the teeth is such that rotation can occur in only one
direction. Rotation of the ratchet wheel in a clockwise direction is prevented by the pawl
and can only take place when the pawl is lifted. The pawl is normally spring loaded to
ensure that it automatically engages with the ratchet teeth. Thus a winch used to wind up
a cable on a drum may have a ratchet and pawl to prevent the cable unwinding from the
drum when the handle is released.
Fig : Ratchet and Pawl
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
61 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
ELECTRICAL ACTUATION SYSTEMS
The linear and rotary actuation is also effectively done using electrical medium.
Certain advantages over hydraulic actuators make the extensive usage in mechatronic
systems. The switching and control of electrical actuators form the part of mechatronics
systems. The electric systems used as actuators for control are:
1. Switching devices such as mechanical switches, e.g. relays,or solid-state switches,
e.g. diodes, thyristors, and transistors, where the control signal switches on or off
some electrical device, perhaps a heater or a monitor.
2. Solenoid type devices where a current through a solenoid is used to actuate a soft
iron core, as, for example, the solenoid operated hydraulic/ pneumatic valve where
a control current through a solenoid is used to actuate a hydraulic/ pneumatic flow.
3. Drive systems, such as d.c. and a.c. motors, where a current through a motor is
used to produce rotation.
MECHANICAL SWITCHES
Mechanical switches are often used as sensors to give inputs to systems, e.g.
keyboards. The electrical relay is an example of a mechanical switch used in control as
an actuator.
Mechanically opening and closing of electrical circuits by breaking or making
through one or more contact pairs is done by ‘Mechanical switches’. The opening is
transmitted by ‘0’ signal and closing is transmitted by ‘1’. The terminals of separate
electrical circuits that are to be switched by same action are termed as “poles”. The
numbers of individual contacts for each pole are named as “throws”. Based on number
of throws and poles in a switching action, they are classified into the following.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
62 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Table : Mechanical Switches
DESIGN VARIETIES IN MECHANICAL SWITCHES
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
63 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
64 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
RELAYS
Relays are electrically operated switches in which changing a current in one
electrical circuit switches a current on or off in another circuit. For the relay shown in
fig(a), when there is a current through the solenoid of the relay, a magnetic field is
produced which attracts the iron armature ,moves the push-rode, and so closes the
normally open (NO) switch contacts and opens the normally closed (NC) switch
contacts.
Relays are often used in control systems, the output from the controller is a
relatively small current and a much larger current is needed to switch on or off the final
correction element, e.g. the current required by the electric heater in a temperature
control system or a motor. In such a situation they are likely to be used in conjunction
with transistors and fig (b) shows the type of circuit that might be used. Because relays
are inductances they can generate a back voltage when the energizing current is
switched off or when their input switches from a high to low signal. As a result damage
can occur in connecting circuit. To overcome this problem a diode is connected across
the relay. When back e.m.f. occurs the diode conducts and shorts it out.
Fig: (a) A relay and (b) a driver circuit
As an illustration of the ways relays can be used in control systems, fig shows
how two relays might be used to control the operation of pneumatic valves which in
turn control the movement of pistons in three cylinders A, B and C.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
65 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Relay Controlled System
The sequence of operation is:
1. When the start switch is closed, the current is applied to the A and B solenoids
and results in both A and B extending, i.e. A+ and B+.
2. The limit switches a+ and b+ are then closed; a+ closure results in current
flowing through relay oil 1 which then closes its contacts and so supplies current
to the C solenoid and then results in the extending, i.e. C+.
3. Its extension causes limit switch C+ to close and so current to switch the A and B
control valves and hence retraction of the cylinders A and B, i.e. A- and B-.
4. Closing limit switch a- passes a current through the relay coil 2, its contacts close
and allows a current to valve C and cylinder C to retract, i.e. C-.
The sequence thus given by this system is A+ and B+ concurrently, then C+, followed by
A- and B- concurrently and finally C-.
Time delay relays are control relays that have a delayed switching action. The
time delay is usually adjustable and can be initiated when a current flows through the
relay coil or when it ceases to flow through the coil.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
66 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
SOLID STATE SWITCHES
There are a number of solid-state devices which can be used to electronically
switch circuits. These include:
1 Diodes.
2 Thyristors and triacs.
3 Bipolar transistors.
4 Power MOSFETs.
1. Diodes
The diode has the characteristics as shown in figure and so allows a significant
current in one direction only.
Fig : Diode Characteristic
A diode can thus be regarded as a ‘directional element’, only passing a current
when forward biased, i.e. with the anode being positive with respect to the cathode. If
the diode is sufficiently reversed biased, i.e. a very high voltage, it will break down. If
an alternating voltage is applied across a diode, it can be regarded as only switching on
when the direction of the voltage is such as to forward bias it and being off in the
reverse biased direction. The result is that the current through the diode is half-rectified
to become just the current due to the positive halves of the input voltage as shown in
Fig.
Fig : Half-wave rectification
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
67 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2. Thyristors and triacs
The thyristor, or silicon-controlled rectifier (SCR), can be regarded as a diode which
has a gate controlling the conditions under which the diode can be switched on. Figure
shows the thyristor characteristic.
Fig : Thyristor characteristic
With the gate current zero, the thyristor passes negligible current when reverse
biased (unless sufficiently reverse biased, hundreds of volts, when it breaks down).
When forward biased the current is also negligible until the forward breakdown voltage
is exceeded. When this occurs the voltage across the diode falls to a low level, about 1 to
2 V, and the current is then only limited by the external resistance in a circuit.
Thus, for example, if the forward breakdown is at 300 V then when this voltage is
reached the thyristor switches on and the voltage across it drops to 1 or 2 V. If the
thyristor is in series with a resistance of, say, 20 Ω then before breakdown we have a
very high resistance in series with the 20 Ω and so virtually all the 300 V is across the
thyristor and there is negligible current. When forward breakdown occurs, the voltage
across the thyristor drops to, say, 2 V and so there is now 300 - 2 = 298 V across the 20 Ω
resistor, hence the current rises to 298/20 = 14.9 A. Once switched on the thyristor
remains on until the forward current is reduced to below a level of a few milliamps. The
voltage at which forward breakdown occurs is determined by the current entering the
gate, the higher the current the lower the breakdown voltage. The power-handling
capability of a thyristor is high and thus it is widely used for switching high power
applications.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
68 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
3. Bipolar Transistors
Bipolar transistors come in two forms, the npn and the pnp. Figure shows the
symbol for each. For the npn transistor, the main current flows in at the collector and
out at the emitter, a controlling signal being applied to the base. The pnp transistor has
the main current flowing in at the emitter and out at the collector, a controlling signal
being applied to the base.
Fig : Transistor symbols: (a) npn, (b) pnp
For a npn transistor connected as shown in Figure (a), the so-termed common-
emitter circuit, the relationship between the collector current Ic and the potential
difference between the collector and emitter VCE is described by the series of graphs
shown in Figure (b). When the base current IB is zero the transistor is cut off; in this
state both the base-emitter and the base-collector junctions are reverse biased. When the
base current is increased, the collector current increases and VCE decreases as a result of
more of the voltage being dropped across Rc. When VCE reaches a value VCE(sat), the base-
collector junction becomes forward biased and the collector current can increase no
further, even if the base current is further increased. This is termed saturation. By
switching the base current between 0 and a value that drives the transistor into
saturation, bipolar transistors can be used as switches. When there is no input voltage
Vin then virtually the entire Vcc voltage appears at the output. When the input voltage is
made sufficiently high the transistor switches so that very little of the Vcc voltage
appears at the output (Fig. (c)).
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
69 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Transistor Switch
4. MOSFETs
MOSFETS (metal-oxide field-effect transistors) come in two types, the n-channel
and the p-channel. Figure shows the symbols. The main difference between the use of a
MOSFET for switching and a bipolar transistor is that no current flows into the gate to
exercise the control. The gate voltage is the controlling signal. Thus drive circuitry can
be simplified in that there is no need to be concerned about the size of the current.
Fig: MOSFETs: (a) n-channel, (b) p-channel
With MOSFETs, very high frequency switching is possible, up to 1 MHz, and
interfacing with a microprocessor is simpler than with bipolar transistors.
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
70 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
SOLENOIDS
Solenoids can be used to provide electrically operated actuators. Solenoid valves
are an example of such devices, being used to control fluid flow in hydraulic or
pneumatic systems. When a current passes through a coil a soft iron core is pulled into
the coil and, in doing so, can open or close ports to allow the flow of a fluid.
Construction
Solenoid has a fixed ferrous body with a coil for excitation. The centrally
positioned is the plunger which is a movable element. The body and the plunger
(armature) are made of ferro magnetic material for flux carrying. Tube carries a conical
stopper plate at one end, which is also magnetic.
Fig : Construction of a solenoid
Principle of Working
Switching on the current the body and the conical stopper get magnetized
because of which the plunger is attracted towards the stopper. On switching off current
to the coil plunger returns back to the free position.
Solenoids are basically short stroke (up to 25 mm) unidirectional linear electrical
actuators in which the action is always to pull the plunger into the coil irrespective of
the polarity of the current. The force· of actuation supplied by the simple solenoid of the
type shown in figure is given by
02
22
μA x
I N
2
1 F
=
Module |1 I n t r o d u c t i o n t o M e c h a t r o n i c s
71 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
where N = number of turns on the coil
I = the current through the coil
x = length of air gap
A = Area of cross-section of air gap.
μ0 = permeability of air.
Characteristic of Solenoid
The force exerted by the plunger is maximum in the beginning and varies non-
linearly as the stroke progresses. The plunger force decreases with the stroke, as shown
in figure
Fig : Force stroke current.
REFERENCES
1) Mechatronics - W. Bolton
2) Mechatronics - Ganesh S. Hegde
3) Control Systems and Mechatronics - J.Srinivas
4) Mechatronics - Dan S. Necsuleseu
5) Understanding Electro Mechanical Engineering - Lawrence J. Kamm
6) Mechatronics - Principles, Concepts & Applications
- Nitaigour Premchand Mahalik
Module |2 I n p u t / o u t p u t S y s t e m s
72 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MODULE - 2
INPUT/OUTPUT SYSTEMS
INPUT/OUTPUT SYSTEMS
When a microprocessor is used to control some system it has to accept input
information, respond to it and produce output signals to implement the required
control action. Thus there can be inputs from sensors to feed data in and outputs to
such external devices as relays and motors. The term peripheral is used for a device,
such as a sensor, keyboard, actuator, etc. which is connected to a microprocessor. It is
however, not normally possible to connect directly such peripheral devices to a
microprocessor bus system due to a lack of compatibility in signal forms and levels.
Because of such incompatibility, a circuit known as an interface is used between the
peripheral items and the microprocessor. Figure illustrates the arrangement. The
interface is where this incompatibility is resolved.
Fig : The interfaces
INPUT/OUTPUT PORTS
In computer hardware, a 'port' serves as an interface between the computer and
other computers or peripheral devices. Physically, a port is a specialized outlet on a
piece of equipment to which a plug or cable connects. Electronically, the several
conductors making up the outlet provide a signal transfer between devices. Computer
ports in common use cover a wide variety of shapes such as round (PS/2, etc.),
rectangular (FireWire, etc.), square (telephone modem), trapezoidal (D-Sub—the old
printer port was a DB-25), etc. There is some standardization to physical properties
and function. For instance, most computers have a keyboard port (currently a round
DIN-like outlet referred to as PS/2), into which the keyboard is connected.
Module |2 I n p u t / o u t p u t S y s t e m s
73 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Electronically, hardware ports can almost always be divided into two groups
based on the signal transfer:
• Serial ports send and receive one bit at a time via a single wire pair (Ground
and +/-).
• Parallel ports send multiple bits at the same time over several sets of wires.
After ports are connected, they typically require "handshaking", which is a
similar concept to the negotiation that occurs when two fax machines make a
connection, where transfer type, transfer rate, and other necessary information is
shared even before data are sent.
Plug-and-play ports are designed so that the connected devices automatically
start handshaking as soon as the hot-plugging is done. USB ports and FireWire ports
are plug-and-play.
Auto-detect or auto-detection ports are usually plug-and-play, but they offer
another type of convenience. An auto-detect port may automatically determine what
kind of device has been attached, but it also determines what purpose the port itself
should have. For example, some sound cards allow plugging in several different types
of audio speakers, then a dialogue box pops up on the computer screen asking
whether the speaker is left, right, front, or rear for surround sound installations. The
user's response determines the purpose of the port, which is physically a 1/8" tip-
sleeve-ring (TRS connector) mini jack. Some auto-detect ports can even switch
between input and output based on context.
FireWire ports used with video equipment (among other devices) can be either
4-pin or 6-pin. The two extra conductors in the 6-pin connection carry electrical
power. This is why a self-powered device such as a camcorder often connects with a
cable that is 4-pins on the camera side and 6-pins on the computer side, the two power
conductors simply being ignored. This is also why laptop computers usually only
have 4-pin FireWire ports, since they cannot provide enough power to meet
requirements for devices needing the power provided by 6-pin connections.
Note that optical (light) fiber, microwave, and other technologies (i.e.,
quantum) have different kinds of connections, since metal wires aren't effective for
signal transfers with these technologies. Optical connections are usually a polished
glass or plastic interface, possibly with oil that lessens refraction between the two
interface surfaces. Microwaves are conducted through a pipe, which can be seen on a
large scale by examining microwave towers with "funnels" on them leading to pipes.
Module |2 I n p u t / o u t p u t S y s t e m s
74 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Hardware port trunking (HPT) is a technology that allows multiple hardware
ports to be combined into a single group, effectively creating a single connection with
a higher bandwidth, sometimes referred to as a double-barrel approach. This
technology also provides a higher degree of fault tolerance since a failure on one port
may just mean a slow-down rather than a dropout. Compare this to Software Port
Trunking (SPT) where two agents (websites, channels, etc.) are bonded into one with
the same effectiveness, i.e., ISDN B1 (64K) plus B2 (64K) equals data throughput of
128K.
The figures of commonly used Input/output Ports are
Module |2 I n p u t / o u t p u t S y s t e m s
75 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
INTERFACE REQUIREMENTS
The following are some of the actions that are often required of an interface
circuit:
1. Electrical buffering/isolation
This is needed when the peripheral operates at a different voltage or current to
that on the microprocessor bus system or there are different ground references. The
term buffer is used for a device that provides isolation and current or voltage
amplification. For example, if the output of a microprocessor is connected to the base
of a transistor, the base current required to switch the transistor is greater than that
supplied by the microprocessor and so a buffer is used to step up the current. There
also has often to be isolation between the microprocessor and the higher power
system.
2. Timing control
Timing control is needed when the data transfer rates of the peripheral and the
microprocessor are different, e.g. when interfacing a microprocessor to a slower
peripheral. This can be achieved by using special lines between the microprocessor
and the peripheral to control the timing of data transfers. Such lines are referred to as
handshake lines and the process as handshaking. The peripheral sends a DATA READY
signal to the input/output section. The CPU then determines that the DATA READY
signal is active. The CPU then reads the data from the input/output section and sends
an INPUT ACKNOWLEDGED signal to the peripheral. This signal indicates that the
transfer has been completed and thus the peripheral can send more data. For an
output, the peripheral sends an OUTPUT REQUEST or PERIPHERAL READY signal
to the input/output section. The CPU determines that the PERIPHERAL READY
signal is active and sends the data to the peripheral. The next PHERIPHERAL READY
signal may be used to inform the CPU that the transfer has been completed.
3. Code conversion
This is needed when the codes used by the peripherals differ from those used
by the microprocessor. For e.g., an LED display might require a decoder to convert the
BCD output from a microprocessor into the code required to operate the seven display
elements.
Module |2 I n p u t / o u t p u t S y s t e m s
76 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PERIPHERAL INTERFACE ADAPTERS
Interfaces can be specifically designed for particular inputs/outputs; however,
programmable input/output interface devices are available which permit various
different input and output options to be selected by means of software. Such devices
are known as Peripheral interface adapters (PIAs).
A commonly used PIA parallel interface is Motorola MC 6821. It is part of
MC6800 family and thus can be directly attached to Motorola MC6800 & MC68HC11
buses. The device can be considered to be essentially just two parallel input/output
ports, with their control logic, to link up with the host microprocessor. Figure shows
the basic structure of the MC6821 PIA and the pin connections.
Fig : MC6821 PIA
Module |2 I n p u t / o u t p u t S y s t e m s
77 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The PIA contains two 8-bit parallel data ports, termed A and B. Each port has:
1. A peripheral interface register. An output has to operate in a different way to an
input port because the data must be held for the peripheral. Thus for output a
register is used to temporarily store data. The register is said to be latched, that is
connected, when a port is used for output and unlatched when used for input.
2. A data direction register that determines whether the input/output lines are inputs
or outputs.
3. A control register that determines the active logical connections in the peripheral.
4. Two control lines, CA1 and CA2 or CB1 or CB2.
Two microprocessor address lines connect the PIA directly through the two
register select the lines RS0 and RS1. This gives the PIA four addresses for the six
registers. When RS1 is low, side A is addressed and when high it is side B. RS0
addresses registers on a particular side, i.e. A or B. When RS0 is high, the control
register is addressed, when low the data register or the data direction register. For a
particular side, the data register and the data direction register have the same address.
Which of them is addressed is determined by bit 2 of the control register.
Each of the bits in the A and B control registers is concerned with some features
of the operation of the ports. Thus for the A control register we have the bits shown in
figure. A similar pattern is used for the B control register.
Fig : Control register
Bits 0 to 1
The first two bits control the way that CA1 or CB1 input control lines operate. Bit 0
determines whether the interrupt output is enabled. BO = 0 disables the IRQA(B)
microprocessor interrupt, BO = 1 enables the interrupt. CA1 and CB1 are not set by the
static level of the input but are edge triggered, i.e. set by a changing signal. Bit 1
determines whether bit 7 is set by a high-to-low transition (a trailing edge) or a low -
to- high transition (a leading edge). B1 = 0 sets a high-to-low transition, B1 = 1 sets a
low-to-high transition.
Module |2 I n p u t / o u t p u t S y s t e m s
78 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Bit 2
Bit 2 determines whether data direction register or peripheral data registers are
addressed. With B2 sets to 0 data direction registers are addressed, with B2 sets set to
1 peripheral data registers are selected.
Bit 3, 4 and 5
These bits allow the PIA to perform a variety of functions. Bit 5 determines whether
control line 2 is an input or an output. If bit 5 is set to 0 control line 2 is an input, if set
to1 it is an output. In input mode, both CA2 and CB2 operate in the same way. Bit 3
and 4 determine whether the interrupt output is active and which transitions set bit 6.
With B5 = 0, i.e. CA2(CB2) set as an input: B3 = 0 disables IRQA(B)
microprocessor interrupt by CA2(CB2); B3 = 1 enables IRQA(B) microprocessor
interrupt by CA2(CB2); B4 = 0 determines that the interrupt flag IRQA(B), bit B6, is set
by high-to-low transition on CA2(CB2), B4 = 1 determines that it is set by a low-to-
high transition.
B5 = 1 sets CA2(CB2) as an output. In output mode CA2 and CB2 behave
differently. For CA2: with B4 = 0 and B3 = 0, CA2 goes low on the first high-to-low
ENABLE (E) transition following a microprocessor read of peripheral data register A
and is returned high by the next CA1 transition; B4 = 0 and B3 = 1, CA2 goes low on
the first high-to-low ENABLE transition following a microprocessor read of the
peripheral data register A and is returned high by the next high-to-low ENABLE
transition.
Bit 6
This is the CA2(CB2) interrupt flag, being set by transitions on CA2(CB2). With
CA2(CB2) as an input (B5 = 0), it is cleared by a microprocessor read of the data
register A(B). With CA2(CB2) as an output (B5 = 1), the flag is 0 and is not affected by
CA2(CB2) transitions.
Bit 7
This is the CA1(CB1) interrupt flag, being cleared by a microprocessor read of data
register A(B).
The process of selecting which options are to be used is termed configuring or
initializing the PIA. The RESET connection is used to clear all the registers of the PIA.
The PIA must then be initialized.
Module |2 I n p u t / o u t p u t S y s t e m s
79 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PROGRAMMABLE LOGIC CONTROLLERS
A programmable logic Controller (PLC) is a digital electronic device that uses a
programmable memory to store instructions and to implement functions such as logic,
sequencing, timing, counting and arithmetic in order to control machines and
processes and has been specifically designed to make programming easy.
Fig : Programmable logic controller
The term logic is used because the programming is primarily concerned with
implementing logic and switching operations. Inputs devices, e.g. switches, and
output devices, e.g. motors, being controlled are connected to the PLC and then the
controller monitors the inputs and outputs according to the program stored in the
PLC by the operator and so controls the machine or process. Originally they were
designed as a replacement for hard-wired relay and timer logic control systems. PLCs
have the great advantage that it is possible to modify a control system without having
to rewire the connections to the input and output devices, the only requirement being
that an operator has to key in a different set of instructions. Also they are much faster
than relay-operated systems. The result is a flexible system which can be used to
control systems which vary quite widely in their nature and complexity. Such systems
are widely used for the implementation of logic control functions because they are
easy to use and program.
PLCs are similar to computers but have certain features which are specific to
their use as controllers. These are:
1. They are rugged and designed to withstand vibrations, temperature, humidity and
noise.
2. The interfacing for inputs and outputs is inside the controller.
3. They are easily programmed and have an easily understood programming
language. Programming is primarily concerned with logic and switching
operations.
Module |2 I n p u t / o u t p u t S y s t e m s
80 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PLCs were first conceived in 1968. They are now widely used and extend from
small self-contained units for use with perhaps 20 digital input/outputs to modular
systems which can be used for large numbers of inputs/outputs, handle digital or
analogue inputs/outputs, and also carry out PID control modes. The next section is a
discussion of the basic structure of PLCs and how they can be used to control
machines or processes.
BASIC STRUCTURE
It consists of a central processing unit (CPU), memory, and input/output
circuitry. The CPU controls and processes all the operations within the Programmable
Logic Controller (PLC). It is supplied with a clock with a frequency of typically
between 1 and 8 MHz. This frequency determines the operating sped of the PLC and
provides the timing and synchronization for all elements in the system. A bus system
carries information and data to and from the CPU, memory and input/output units.
There are several memory elements: a system ROM to give permanent storage for the
operating system and fixed data, RAM for the user’s program, and temporary buffer
stores for the input/output channels.
The programs in RAM can be changed by the user. However, to prevent the
loss of these programs when the power supply is switched off, a battery is likely to be
used in the PLC to maintain the RAM contents for a period of time. After a program
has been developed in RAM it may be loaded into an EPROM memory chip and so
made permanent. Specifications for small PLCs often specify the program memory
size in terms of the number of program steps that can be stored. A program step is an
instruction for some event to occur. A program task might consist of a number of
steps and could be, for example: examine the state of switch A, examine the state of
switch B , if A and B are closed then energise solenoid P which then might result in
the operation of some actuator. When this happens another task might be started.
Typically, the number of steps that can be handled by a small PLC is of the order of
300 to 1000, which is generally more than adequate for most of the control situations.
Module |2 I n p u t / o u t p u t S y s t e m s
81 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Architecture of a PLC
PLC PROGRAMMING
PLC programming based on the use of ladder diagrams involves writing a
program in a similar manner to drawing a switching circuit. The ladder diagram
consists of two vertical lines representing the power rails. Circuits are connected as
horizontal lines, i.e. the rungs of the ladder, between these two verticals. Fig. shows
the basic standard symbols that are used and an example of rungs in a ladder
diagram.
In drawing the circuit line for a rung, inputs must always precede outputs and
there must be at least one output on each line. Each rung must start with an input or a
series of inputs and end with an output.
Module |2 I n p u t / o u t p u t S y s t e m s
82 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Ladder diagram
The inputs and outputs are numbered, the notation used depending on the
PLC manufacturer, e.g. the Mitsubishi F series of PLCs precedes input elements by an
X and output elements by a Y and uses the following numbers:
Inputs X400-407, 410-413
X500-507, 510-513 (24 possible outputs)
Outputs Y430-437
Y530-537 (16 possible inputs)
To illustrate the drawing of a ladder diagram, consider a situation where the
output from the PLC is to energise a solenoid when a normally open start switch
connected to the input is activated by being closed shown in fig (a). The program
required is shown in fig (b). Starting with the input, we have the normally open
symbol . This might have an input address Y400. The line terminates with the
output, the solenoid; with the symbol O. this might have the output address Y430. To
indicate the end of the program the end rung is marked. When the switch is closed the
solenoid is activated. This might, for example, be a solenoid valve which opens to
allow water to enter the vessel.
Module |2 I n p u t / o u t p u t S y s t e m s
83 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : Switch controlling a solenoid
LOGIC FUNCTIONS
The logic functions can be obtained by combinations of switches and the following
shows how we can write ladder program for such combinations.
1. AND
Following figure (a) shows a situation where a coil is not energized unless two,
normally open, switches are both closed. Switch A and switch B have both to be
closed, which thus gives an AND logic situation. The ladder diagram starts with
, labelled Input 1, to represent switch A and in series with it , labelled Input
2, to represent switch B. The line then terminates with O to represent the output.
Figure (b) shows the line.
Fig : An AND system
2. OR
Figure (a) shows a situation where a coil is not energized until either, normally
open, switched A or B is closed. The situation is an OR logic gate. The ladder
diagram starts with , labelled Input 1, to represent switch A and in parallel with
it , labelled Input 2, to represent switch B. The line then terminates with O to
represent the output. Figure (b) shows the line.
Module |2 I n p u t / o u t p u t S y s t e m s
84 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : An OR system
3. NOR
Figure (a) shows how we can represent the ladder program line for a NOR gate.
Since there has to be an output when neither A nor B have an input and when
there is an input to A or B the output ceases, the ladder program shows Input 1 in
parallel with Input 2, with both being represented by normally closed contacts .
Fig : A NOR system
4. NAND
Figure shows a NAND gate. There is no output when A and B have an input.
Thus for a ladder program line to obtain an output we require no inputs to Input
1 and to Input 2.
Fig : A NAND system
Module |2 I n p u t / o u t p u t S y s t e m s
85 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
DATA HANDLING
With the exception of the shift register, the previous parts of this module have
been concerned with the handling of individual bits of information, eg. a switch being
closed or not. There are, however, some control tasks where it is useful to deal with
related groups of bits, e.g. a block of eight inputs, and so operate on them as a data
word. Such a situation can rise when a sensor supplies an analogue signal which is
converted to, say, an 8-bit word before becoming an input to a PLC.
The operations that may be carried out with a PLC on data word normally
include:
1. Moving data.
2. Comparison of magnitudes of data, i.e. greater than, equal to, or less than.
3. Arithmetic operations such as addition and subtraction.
4. Conversions between binary coded decimal (BCD), binary and octal.
As discussed earlier, individual bits have been stored in memory locations
specified by unique addresses. For example, for the Mitsubishi PLC, input memory
addresses have been preceded by an A, output by a Y, timers by a T, auxiliary relays
by an M, etc. Data instructions also require memory addresses and the locations in the
PLC memory allocated for data are termed data registers. Each data register can store a
binary word of, usually, 8 or 16 bits and is given an address such as D0, D1, D2 etc.
An 8- bit word means that a quantity is specified to a precision of 1 in 256, a 16-bit a
precision of 1 in 65 536.
Each instruction has to specify the form of the operation, the source of the data
used in terms of its data register and the destination data register of the data.
1. DATA MOVEMENT
For data movement the instructions will contain the move data instruction, the
source addresses of the data and the destination address of the data. Thus the ladder
rung could be of the form shown in figure and the instructions could be, when data is
to be moved from data register D1 to data register D2:
Module |2 I n p u t / o u t p u t S y s t e m s
86 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Such data transfers might be to move a constant into a data register, a time or count
value to a data register, data from a data register to a timer or counter, data from a
data register to an output, input data to a data register, etc.
Fig : Move data
2. DATA COMPARISON
PLCs can generally make the data comparisons of less than (usually denoted by
< or LES), equal to (= or EQU), less than or equal to (≤ or <= or LEQ), greater than (> or
GRT), greater than or equal to (≥, >= or GEQ) and not equal to ( ≠ or <> or NEQ). To
compare data, the program instruction will contain the comparison instruction, the
source address of the data and the destination address. Thus to compare the data in
register D1 to see if it is greater than data in data register D2, the ladder program rung
would be of the form shown in figure
Fig : Compare data
Module |2 I n p u t / o u t p u t S y s t e m s
87 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The instructions would be:
Such a comparison might be used when the signals from two sensors are to be
compared by the PLC before action is taken. For example, an alarm might be required
to be sounded if a sensor indicates a temperature above 800C and remain sounding
until the temperature falls below 700C. Figure shows the ladder program that could
be used.
Fig : Temperature alarm
The input temperature data is inputted to the source address and the
destination addresses contains the set value. When the temperature raises to 800C, or
higher, the data value in the source address becomes ≥ the destination address value
and there is an output to the alarm which latches the input. When the temperature
falls below 700C, or lower, the data value in the source address becomes ≤ to the
destination address value and there is an output to the relay which then opens its
contacts and so switches the alarm off.
3. ARITHMETIC OPERATIONS
Some PLCs can carry out just the arithmetic operations of addition and
subtraction, others have even more arithmetic functions. The instruction to add or
subtract generally states the instruction, the register containing the address of the
Module |2 I n p u t / o u t p u t S y s t e m s
88 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
value to be added or subtracted, the address of the value to which the addition or
from which the subtraction is to be made and the register where the result is to be
stored. Figure shows the form used for the ladder symbol for addition with OMRON.
Fig : Add data
Addition or subtraction might be used to alter the value of some sensor input
value, perhaps a correction or offset term, or alter the present values of timers or
counters.
4. CODE CONVERSIONS
All the internal operation in the CPU of a PLC are carried out using binary
numbers. Thus, when the input is a signal which is decimal, conversion to binary
coded decimal (BCD) is used. Likewise, where a decimal output is required,
conversion to decimal is required. Such conversion are provided with most PLCs. For
example, with Mitsubishi, the ladder rung to convert BCD to binary is of the form
shown in figure. The data at the source address is in BCD and converted to binary and
placed at the destination address.
Fig : BCD to binary
Module |2 I n p u t / o u t p u t S y s t e m s
89 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
COMMUNICATION SYSTEMS
DIGITAL COMMUNICATIONS
An external bus is a set of signal lines that interconnects microprocessors,
microcontrollers, computers and PLCs and also connects them with peripheral
equipment. Thus a computer needs to have a bus connecting it with a printer if its
output is to be directed to the printer and printed. Multiprocessor systems are quite
common. For example, in a car there are likely to be several microcontrollers with
each controlling a different part of the system, e.g. engine management, braking and
instrument panel, and communication between them is necessary. In automated plant
there is not only a need for data to pass between programmable logic controllers,
displays, sensors, and actuators and allow for data and programs to be inputted by
operator , but they can also be data communications with other computers. There
may, for example, be a need to link a PLC into a control system involving a number of
PLCs and computers. Computer integrated manufacturing (CIM) is an example of a
large network which can involve large numbers of machines linked together. This
chapter is a consideration how such data communications between computers can
take place, whether it is just simply machine-to-machine or a large network involving
large numbers of machines linked together, and the forms of standard communication
interfaces.
CENTRALISED, HIERARCHIAL AND DISTRIBUTED CONTROL
Centralized computer control involves the use of one central computer to control
an entire plant. This has the problem that failure of the computer results in the loss of
control of the entire plant. This can be avoided by the use of dual computer systems. If
one computer fails the other one takes over. Such centralized systems were common
in the 1960s and 1970s. The development of the microprocessor and the ever reducing
costs of computers have led to multi-computer systems becoming more common and
the development of hierarchical and the distributed systems.
With the hierarchical system, there is a hierarchical system of computers
according to the tasks they carried out. The computers handling the more routine
tasks are supervised by computers which have a greater decision-making role. For
example, the computers which are used for direct digital control of systems are
subservient to a computer which performs supervisory control of the entire system.
The work is divided between the computers according to the function involved. There
is a specialization of computers with some computers only receiving some
information and others different information.
Module |2 I n p u t / o u t p u t S y s t e m s
90 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
With the distributed system, each computer system carries out essentially similar
tasks to all the other computer systems. In the event of a failure of one, or over loading
of a particular computer, work can be transferred to other computers. The work is
spread across all the computers and not allocated to specific computers according to
the function involved. There is no specialization of computers. Each computer thus
needs access to all the information in the system.
In most modern systems there is generally a mixture of distributed and
hierarchical systems. For example, the work of measurement and actuation may be
distributed among a number of microcontrollers/computers which are linked together
and provide the data base for the plant. These may be overseen by a computer used
for direct digital control or sequencing and this in turn may be supervised by one
used for supervisory control of the plant as a whole. Typical levels in such a scheme
are:
Level 1: Measurement and actuators
Level 2: Direct digital and sequence control
Level 3: Supervisory control
Level 4: Management control and design
Distributed/ Hierarchical systems have advantage of allowing the task of
measurement scanning and signal conditioning in control systems to be carried out by
sharing it between a number of microprocessors. This can involve a large number of
signals with a high frequency of scanning. If extra measurement loops are required, it
is a simple matter to increase the capacity of the system by adding microprocessors.
The units can be quite widely dispersed, being located near the source of the
measurements. Failure of one unit does not result in failure of the entire system.
1. PARALLEL AND SERIAL DATA TRANSMISSION
Data communication can be via parallel or serial transmission links.
A. PARALLEL DATA TRANSMISSION
With in computers, data transmission is usually by parallel data paths. Parallel
data buses transmit 8, 16 or 32 bits simultaneously, having a separate bus wire for
each data bit and the control signals. Thus, if there are 8 data bits to be transmitted,
e.g. 11000111, then 8 data wires are needed. The entire 8 data bits are transmitted in
the same time as it takes to transmit 1 data bit because each bit is on a parallel wire.
Module |2 I n p u t / o u t p u t S y s t e m s
91 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Handshaking lines are also needed, handshaking being used for each character
transmitted with lines needed to indicate that data is available for transmission and
that the receiving terminal is ready to receive. Parallel data transmission permits high
data transfer rates but is expensive because of the cabling and interface circuitry
required. It is thus normally only used over short distances or where high transfer
rates are essential.
SERIAL DATA TRANSMISSION
This involves the transmission of data which, together with control signals, is
sent bit by bit in sequence along a single line. Only two conductors are needed, to
transmit data and to receive data. Since the bits of a word are transmitted sequentially
and not simultaneously, the data transfer rate is considerably less than with parallel
data transmission. However, it is cheaper since far fewer conductors are required. For
example, with a car when a number of microcontrollers are used, the connections
between them are by serial data transmission. Without the use of serial transmission
the number of wires involved would be considerable. In general, serial data
transmission is used for all but the shortest peripheral connections.
Consider the problem of sending a sequence of characters along a serial link.
The receiver needs to know where one character starts and stops. Serial data
transmission can be either asynchronous or synchronous transmission. Asynchronous
transmission implies that both the transmitter and receiver computers are not
synchronized, each having its own independent clock signals. The time between the
transmitted characters is arbitrary. Each character transmitted along the link is thus
preceded by a start bit to indicate to the receiver the start of a character, and followed
by a stop bit to indicate its completion. This method has the disadvantage of requiring
extra bits to be transmitted along with each character and thus reduces the efficiency
of the line for data transmission. With synchronous transmission there is no need for
start and stop bits since the transmitter and receiver have a common clock signal and
thus characters automatically start and stop always at the same time in each cycle.
The rate of data transmission is measured in bits per second. If the group of n bits
forms a single symbol being transmitted and the symbol has duration of T seconds
then the data rate of transmission is n/T .The baud is the unit used. The baud rate is
only the same as the number of bits per second transmitted if each character is
represented by just one symbol. Thus a system which does not use start and stop
pulses have a baud rate equal to the bit rate, but this will not be the case when there
are such bits.
Module |2 I n p u t / o u t p u t S y s t e m s
92 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2. SERIAL DATA COMMUNICATION MODES
Serial data transmission occurs in one of the three modes:
2.1. SIMPLEX MODE
Transmission is only possible in one direction, from device A to device B,
where device B is not capable of transmitting back to device A. You can think of the
connection between the devices being like a one-way road. This method is usually
only used for transmission to devices such as printers which never transmit
information.
2.2. HALF-DUPLEX MODE
Data is transmitted in one direction at a time but the direction can be changed.
Terminals at each end of the link can be switched from transmit to receive. Thus
device A can transmit to device B and device B to device A but not at the same time.
You can think of this being like two lane road under repair with traffic from one lane
being stopped by a traffic control to allow the traffic for the other lane through.
Citizens Band (CB) radio is an example of half-duplex mode, a person can receive or
talk but not do both simultaneously.
2.3. FULL-DUPLEX MODE
Data may be transmitted simultaneously in both directions between devices A
and B. This is like a two lane high way in which traffic can occur in both directions
simultaneously. The telephone system is an example of full-duplex mode in that a
person can talk and receive at the same time.
Module |2 I n p u t / o u t p u t S y s t e m s
93 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
NETWORKS
The term Network is used for a system which allows two or more computers/
microprocessors to be linked for the interchange of data. The logical form of the links
is known as the network topology. The term node is used for a point in a network
where one or more communication lines terminate or a unit is connected to the
communications lines. Commonly used forms are:
1. Data Bus:
This has a linear bus (shown in figure) into which all the stations are plugged.
This system is often used for multipoint clusters. It is generally the preferred method
for distances between nodes of more has 100 m.
2. Star:
This has dedicated channels between each station and a central switching hub
(shown in figure) through which all communications must pass. This is the type of
network used in the telephone systems (private branch exchanges (PBXs)) in many
companies, all the lines passing through a central exchange. This system is also often
used to connect remote and local terminals to a central mainframe computer. There is
a major problem with this system in that if the central hub fails then the entire system
fails.
3. Hierarchy or Tree:
This consists of a series of branches converging indirectly to a point at the head
of the tree (shown in figure). With this system there is only one transmission path
between any two stations. This arrangement may be formed from a number of linked
data bus systems. Like the bus method, it is often used for distances between nodes of
more than 100 m.
Module |2 I n p u t / o u t p u t S y s t e m s
94 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
4. Ring:
This is very popular method for local area networks, involving each station
being connected to a ring (shown in figure). The distances between nodes are
generally less than 100 m. Data put into the ring system continuous to circulate round
the ring until some system removes it. The data is available to all the stations.
5. Mesh:
This method (shown in figure) has no formal pattern to the connections
between stations and there will be multiple data path between them.
The term local area network (LAN) is used for a network over a local geographic
area such as a building or a group of buildings on one site. The topology is commonly
bus, star or ring. A wide area network is one that interconnects computers, terminals
and local area networks over a national or international level.
Module |2 I n p u t / o u t p u t S y s t e m s
95 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PROTOCOLS
Transmitted data will contain two types of information. One is the data which
one computer wishes to send to another, the other is information termed protocol data
and is used by the interface between a computer and the network to control the
transfer of the data into the network or from the network into the computer. A
protocol is a formal set of rules governing data format, timing, sequencing, access
control and error control. The three elements of a protocol are:
1. Syntax, which defines data format, coding and signal levels.
2. Semantics, which deals with synchronisation, control and error handling.
3. Timing, which deals with the sequencing of data and the choice of data rate.
When a sender communicates with a receiver then both must employ the same
protocol, e.g. two microcontrollers with data to be serially transmitted between them.
With simplex communication the data block can be just sent from sender to receiver.
However, with half-duplex, each block of transmitted data, if valid, must be
acknowledged (ACK) by the receiver before the next block of data can be sent (shown
in figure (a)); if invalid a NAK, negative acknowledgement, signal is sent. Thus a
continuous stream of data cannot be transmitted. The CRC bits, cyclic redundancy
checks, are a means of error detection and are transmitted immediately after a block of
data. The data is transmitted as a binary number and at the transmitter the data is
divided by a number and the remainder is used as the cyclic check code. At the
receiver the incoming data, including the CRC, is divided by the same number and
will give zero remainder if the signal is error free. With full-duplex mode (shown in
figure (b)), data can be continuously sent and received.
Fig : Protocols: (a) half-duplex, (b) full-duplex
Module |2 I n p u t / o u t p u t S y s t e m s
96 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Within a package being sent, there is a need to include protocol information.
For example, with asynchronous transmission there may be characters to indicate the
start and end of data. With synchronous transmission and the Bisync protocol, a data
block is preceded by a synchronising sequence of bits, usually the ASCII character
SYN (shown in figure (a)) The SYN characters are used by the receiver to achieve
character synchronisation, preparing the receiver to receive data in 8-bit groupings.
The Motorola MC6852 is a synchronous serial data adapter (SSDA) that is designed
for use with 6800 microprocessors to provide a synchronous serial communications
interface using the Bisync protocol. It is similar to the asynchronous communications
interface adapter.
Fig : Bisync
Another protocol is the High-level Data Link Control (HDLC). This is a full-
duplex protocol with the beginning and end of a message being denoted by the bit
pattern 01111110. Address and control fields follow the start flag. The address
identifies the address of the destination station, the control field defines whether the
frame is supervisory, information or unnumbered. Following the message is a 16-bit
frame check sequence which is used to give a cyclic redundancy check (CRC). The
Motorola 6854 is an example of a serial interface adapter using this HDLC protocol.
Fig : HDLC
Module |2 I n p u t / o u t p u t S y s t e m s
97 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
OPEN SYSTEM INTERCONNECTION COMMUNICATION MODEL
Communication protocols have to exist on a number of levels. The
International Organization for Standardisation (ISO) has defined a seven-layer
standard protocol system known as the Open Systems Interconnection (OSI) model. The
model is a framework for developing a co-ordinated system of standards. The layers
are:
1. Physical layer
This layer describes the means for bit transmission to and from physical
components of the network. It deals with hardware issues, e.g. the types of cable
and connectors to be used, synchronising data transfer and signal levels.
Commonly used LAN systems defined at the physical layer is Ethernet and token
ring.
2. Data link layer:
This layer defines the protocols for sending and receiving messages, error
detection and correction and the proper sequencing of transmitted data. It is
concerned with packaging data into packets and placing them on the cable and
then taking them off the cable at the receiving end. Ethernet and token ring are
also defined at this level.
3. Network layer:
This deals with communication paths and addressing, routing and control of
messages on the network and thus making certain that the messages get to the
right destinations. Commonly used network layer protocol layers are Internet
Protocol (IP) and Novell’s Internetwork Packet Exchange (IPX).
4. Transport layer;
This provides for reliable end-to-end message transport. It is concerned with
establishing and maintaining the connection between transmitter and receiver.
Commonly used transport layer protocols are Internet Transmission Control
Protocols (TCP) and Novell’s Sequenced Packet exchange (IPX).
5. Session layer:
This layer is concerned with the establishment of dialogues between application
processes which are connected together by the network. It is responsible for
determining when to turn a communication between two stations ON or OFF.
6. Presentation layer:
This layer is concerned with allowing the encoded data transmitted to be
presented in a suitable form for user manipulation.
7. Application layer:
This layer provides the actual user information processing function and
application specific services. It provides such functions as file transfer or electronic
mail which a station can use to communicate with other systems on the network.
Module |2 I n p u t / o u t p u t S y s t e m s
98 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
COMMUNICATION INTERFACES
Digital data can be communicated between devices by serial or parallel
communication. With serial communications the main standard is RS-232. With
parallel communications commonly used standards are the Centronics parallel interface
and the general purpose interface bus (GPIB) (IEEE-488).
1. SERIAL COMMUNICATION INTERFACE
The most popular serial interface is RS-232; this was first defined by the
American Electronics Industries Association (EIA) in1962. The standard relates to data
terminal equipment (DTE) and data circuit-terminating equipment (DCE). Data
terminal equipment can send or receive data via the interface, e.g. a microcontroller.
Data circuit-terminating equipment is devices which facilitate communication; a
typical example is a modem. This forms an essential link between a microcomputer
and a conventional analog telephone line.
RS-232 signals can be grouped into three categories:
a. Data
RS-232 provides two independent serial data channels, termed primary and
secondary. Both these channels are used for full-duplex operation.
b. Handshake Control
Handshaking signals are used to control the flow of serial data over the
communication path.
c. Timing
For synchronous operation it is necessary to pass clock signals between
transmitters and receivers.
The connector to a RS-232C serial port is via a 25-pin D-type connector; usually
a male plug is used on cable and a female socket on the DCE or DTE.
For the simplest bi-directional link only the two lines 2 and 3 for transmitted
data and received data, with signal ground for the return path of these signals, are
needed (shown in figure (a)). Thus the minimum connection is via a three-wire cable.
For a simple set-up involving a personal computer (PC) being linked with a visual
display unit (VDU) pins 1, 2, 3, 4, 5, 6, 7 and 20 are involved (shown in figure (b)). The
signal send through pins 4, 5, 6 and 20 are used to check that the receiving end is
ready to receive a signal; a transmitting end is ready to send and the data is ready to
be sent.
Module |2 I n p u t / o u t p u t S y s t e m s
99 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : RS-232 connections: (a) minimum configuration, (b) PC connection
RS-232 is limited concerning the distance over which it can be used as noise
limits the transmission of high numbers of bits per second when the length of the
cable is more than about 15 m. The maximum data rate is about 20 kbits/s. Other
standards such as RS-422 and RS-485 are similar to RS-232 and can be used for higher
transmission rates and longer distances.
RS-422 uses a pair of lines for each signal and can operate up to about 1220
meters or at higher transmission speed up to 100 bits/s and in noisier environments;
maximum speed and maximum distance cannot, however, be achieved
simultaneously. RS-485 can be used up to about 1220 m with speed of 100 kbits/s.
2. GENERAL PURPOSE INSTRUMENTATION BUS
The standard interface commonly used for general parallel communications is
the General purpose instrument bus (GPIB), the IEEE-488 standard, originally developed
Hewlett Packard to link their computers and instruments and thus often referred to as
the Hewlett Packard instrumentation bus. Each of the devices connected to the bus is
termed a listener, talker or controller. Listeners are devices that accept data from the
bus, talkers place data, on request, on the bus and controllers manage the flow of data
on the bus by sending command to talkers and listeners and carries out polls to see
which devices are active. The GPIB bus structure is shown below.
Module |2 I n p u t / o u t p u t S y s t e m s
100 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Fig : GPIB bus structure
There are a total of 24 lines with the interface.
1. Eight bi-directional lines to carry data and commands between the various
devices connected to the bus.
2. Five lines for control and status signals.
3. Three lines for handshaking between devices.
4. Eight lines are ground return lines.
Up to 15 devices can be attached to the bus at any one time, each device having
its own address. The 8-bit parallel data bus can transmit data as one 8-bit byte at a
time. Each time a byte is transferred the bus goes through a handshake cycle. Each
device on the bus has its own address.
Commands from the controller are signalled by taking the Attention Line
(ATN) low. Commands are then directed to individual devices by placing address on
the data lines; device addresses are sent via the data lines as a parallel 7-bit word with
the lowest 5 bits providing the device address and the other 2 bits control information.
If both these are zero then the commands are sent to all address; if bit 6 is 1 and bit 7 is
0 the addressed device is switched to be a listener; if bit 6 is 0 and bit 7 is 1 then the
device is switched to be talker.
Handshaking uses the lines DAV, NRFD, and NDAC, the three lines ensuring
that the talker will only talk when it being listened by the listeners (in figure). When a
listener is ready to accept data, NRFD is made high. When data has been placed on
the line, DAV is made low to notify devices that data is available. When a device
accepts a data word it sets NDAC high to indicate that it has accepted the data and
NRFD low to indicate that it is now not ready to accept data. When all the listeners
have set NDAC high, then the talker cancels the data valid signal, DAV going high.
Module |2 I n p u t / o u t p u t S y s t e m s
101 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
This then results in NDAC being set low. The entire process can then be repeated for
another word being put on the data bus.
Fig : Handshaking
The GPIB is a bus which is used to interface a wide range of instruments, e.g.
digital multimeters and digital oscilloscopes, via plug-in boards (shown in figure) to
computers with standard cables used to link the board o the instruments via
interfaces.
Fig : GPIB Hardware
Module |2 I n p u t / o u t p u t S y s t e m s
102 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
FAULT FINDING
This section is a brief consideration of the problems of fault detection with
measurement, control and data communication systems. For details of the fault-
finding checks required for specific systems or components, the manufacturer’s
manuals should be used.
There are a number of techniques that can be used to detect faults:
1. Replication checks
This involves duplicating or replicating an activity and comparing the results. In
the absence of faults it is assumed that the results should be the same. It could
mean, with transient errors, just repeating an operation twice and comparing the
results or it could involve having duplicate systems and comparing the results
given by the two. This can de an expensive option.
2. Expected value checks
Software errors are commonly detected by checking whether an expected value is
obtained when a specific numerical input is used. If the expected value is not
obtained there is a fault.
3. Timing checks
This involves the use of timing checks that some function has been carried out
within a specified time. These checks are commonly referred as watchdog timers.
For example, with a PLC, when an operation starts a timer is also started and if the
operation is not completed within a specified time a fault is assumed to have
occurred. The watchdog timer trips, sets off an alarm and closes down part or the
entire plant.
4. Reversal checks
Where there is direct relationship between input and output values, the value of
the output can be taken and the input which should have caused it computed. This
can then be compared with the actual input.
5. Parity and error coding checks
This form of checking is commonly used for detecting memory and data
transmission errors. Communication channels are frequently subject to
interference which can affect data being transmitted. To detect whether data has
Module |2 I n p u t / o u t p u t S y s t e m s
103 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
been corrupted a parity bit is a bit added to the transmitted data word. The parity
bit is chosen to make the resulting number 1s in the group either odd (odd parity)
or even (even parity). If odd parity then the word can be checked after
transmission to see if it is still odd. Other forms of checking involve codes added to
transmitted data in order to detect corrupt bits.
6. Diagnostic checks
Diagnostic checks are used to test the behaviour of components in a system. Inputs
are applied to a component and the outputs compared with those which should
occur.
I. COMMON HARDWARE FAULTS
The following are some of the commonly encountered faults that can occur
with specific types of components and systems.
1. Sensors
If there are faults in a measurement system then the sensor might be at fault. A simple
test is to substitute the sensor with a new one and see what effect this has on the
results given by the system. If the results change then it is likely that the original
sensor was faulty; if the results do not change then the fault is elsewhere in the
system. It is also possible to check that the voltage/current sources are supplying the
correct voltages/currents, whether there is electrical continuity in connecting wires,
which the sensor is correctly mounted and used under the conditions specified by the
manufacturer’s data sheet, etc.
2. Switches and relays
Dirt and particles of waste material between switch contacts is a common source of
incorrect functioning of material switches. A voltmeter used across a switch should
indicate the applied voltage when the contacts are open and very nearly zero when
they are closed. Mechanical switches used to detect the position of some item, e.g. the
presence of a work piece on a conveyor, can fail to give the correct responses if the
alignment is incorrect or if the actuating lever is bent.
Inspection of a relay can disclose evidence of arcing or contact welding. The
relay should then be replaced. If a relay fails to operate then a check can be made for
the voltage across the coil. If the correct voltage is present then coil continuity can be
checked with an ohmmeter. If there is no voltage across the coil then the fault is likely
to be the switching transistor used with the relay.
Module |2 I n p u t / o u t p u t S y s t e m s
104 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
3. Motors
Maintenance of both d.c. and a.c. motors involves correct lubrication. With d.c. motors
the brushes wear and can require changing. Setting of new brushes needs to be in
accordance with the manufacturer’s specification. A single-phase capacitor start a.c.
motor that is sluggish in starting probably needs a new starting capacitor. The three-
phase induction motor has no brushes, commutator, slip rings or starting capacitor
and short of a severe overload, the only regular maintenance that is required is
periodic lubrication.
4. Hydraulic and pneumatic systems
A common cause of faults with hydraulic and pneumatic systems is dirt. Small
particles of dirt can damage seals, block orifices, cause valve spools to jam, etc. Thus
filters should be regularly checked and cleaned, components should only be
dismantled in clean conditions, and oil should be regularly checked and changed.
FAULT FINDING TECHNIQUES
Fault-finding techniques that are used with microprocessor-based systems
include:
1. Visual inspection
Just carefully looking at a faulty system may reveal the source of a fault, e.g. an
integrated circuit which is loose in its holder or surplus solder bridging tracks on a
board.
2. Multimeter
This is of limited use with microprocessor systems but can be used to check for
short-or open-circuit connection and the power supplies.
3. Oscilloscope
The oscilloscope is essentially limited to where respective signals occur and the
most obvious such signal is the clock signal. Most of the other signals with a
microprocessor system are not repetitive and depend on the program being
executed.
4. Logic probe
The logic probe is a hand-held device shaped like a pen, which can be used to
determine the logic level at any point in the circuit to which it is connected.
Module |2 I n p u t / o u t p u t S y s t e m s
105 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
5. Logic pulsar
The logic pulsar is a hand-held pulse generator, shaped like a pen, which is used to
inject controlled pulse in to circuits. The pulsar probe tip is pressed against a node
in the circuit and the button on the probe pressed to generate a pulse. It is often
used with the logic probe to check the functions of logic gates.
6. Current tracer
The current tracer is similar to the logic probe but it senses the pulsing current in a
circuit rather than voltage levels. The tip of the current tracer is magnetically
sensitive and is used to detect the changing magnetic field near a conductor
carrying a pulsing current. The current tracer tip is moved along printed circuit
tracks to trace out the low-impendence path along which current is flowing.
7. Logic clip
A logic clip is a device which clips to an integrated circuit and makes contact with
each of the integrated circuit pins. The logic state of each pin is then shown by LED
indicators, there being one for each pin.
8. Signature analyser
With analogue systems, fault finding usually involves tracing through the circuitry
and examining the waveforms at various nodes, comparison of the waveforms
with what would be expected enabling faults in to be identified and located. With
digital systems the procedure is more complex since trains of pulses at nodes all
look very similar. To identify whether there is a fault the sequence of pulse is
converted into a more readily identifiable form, this being termed the signature.
The signature obtained at a node can then be compared with that which should
occur. When using the signature analyzer with a circuit, it is often necessary for the
circuit to have been designed so that the data bus feedback paths can be broken
easily for the test to stop faulty digital sequences being fed back during the testing.
A short program, which is stored in ROM, is activated to stimulate nodes and
enable signatures to be obtained. The microprocessor itself can be tested if the data
bus is broken to isolate it from memory and it is then made to ‘free run’ and give a
‘no operation’ (NO) instruction to each of its addresses in turn. The signatures for
the microprocessor bus in this state can then be compared with those expected.
Module |2 I n p u t / o u t p u t S y s t e m s
106 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MECHATRONICS DESIGNS
The design process for any system can be considered as involving a number of stages:
1. The need
The design process begins with a need from, perhaps, a customer or client. This may
be identified by market research being used to establish the needs of potential
customers.
2. Analysis of the problem
The first stage in developing a design is to find out the true nature of the problem, i.e.
analysing it. This is an important stage in that not defining the problem accurately can
lead to wasted time on designs that will not fulfill the need.
3. Preparation of a specification
Following the analysis a specification of the requirements can be prepared. This will
state the problem, any constraints placed on the solution, and the criteria which may
be used to judge the quality of the design. In stating the problem, all the functions
required of the design, together with any desirable features, should be specified. Thus
there might be a statement of mass, dimensions, types and range of motion required,
accuracy, input and output requirements of elements, interfaces, power requirements,
operating environment, relevant standards and codes of practice, etc.
4. Generation of possible solutions
This is often termed the conceptual stage. Outline solutions are prepared which are
worked out in sufficient detail to indicate the means of obtaining each of the required
functions, e.g. approximate sizes, shapes, materials and costs. It also means finding
out what has been done before for similar problems; there is no sense in reinventing
the wheel.
5. Selection of a suitable solution
The various solutions are evaluated and the most suitable one selected.
6. Production of a detailed design
The detail of the selected design has now to be worked out. This might require the
production of prototypes or mock-ups in order to determine the optimum details of a
design.
7. Production of working drawings
The selected design is then translated into working drawings, circuit diagrams, etc. so
that the item can be made.
Module |2 I n p u t / o u t p u t S y s t e m s
107 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MECHATRONICS DESIGN SOLUTIONS
Consider possible solutions to the following requirements for systems to carry
out simple tasks.
Timed Switch
Consider a simple requirement for a device which switches on some actuator, e.g. a
motor, for some prescribed time.
A mechanical solution could involve a rotating cam shown in figure. The cam
would be rotated at a constant rate and the cam follower used to actuate a switch, the
length of time for which the switch is closed depending on the shape of cam.
Fig : Cam-operated switch
A PLC solution could involve the arrangement shown in figure, given below,
with the given ladder program.
Fig : PLC timer system
Module |2 I n p u t / o u t p u t S y s t e m s
108 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
This would have the advantage over the rotating cam of having off and on
times which can be adjusted by purely changing the timer present values in the
program whereas a different cam is needed if the times have to be changed with the
mechanical solution. The software solution is much easier to implement than the
hardware one.
A microprocessor-based solution could involve a microprocessor with a
memory chip and input/output interfaces. The program is then used to switch an
output on and then off after some time delay with the time delay being produced by a
block of program in which there is a timing loop. This generates a time delay by
branching round a loop the number of cycles required to generate the requisite time.
Thus in assembly language we might have:
DEX decrements the index register, and this and BNE, branch if not equal, each take 4
clock cycles. The loop thus take 8 cycles and there will be n such loops until 8n + 3 + 5
gives the number F424 (LDX takes 3 cycles and RTS takes 5 cycles). In C we would
write the program lines using the while function.
ELECTROMECHANICAL SYSTEMS
COMPACT DISC (CD)
A Compact Disc (also known as a CD) is an optical disc used to store digital
data, originally developed for storing digital audio. The CD, available on the market
since late 1982, remains the standard playback medium for commercial audio
recordings to the present day.
Standard CDs have a diameter of 120 mm and can hold up to 80 minutes of
audio. There is also the Mini CD, with diameters ranging from 60 to 80 mm; they are
sometimes used for CD singles, storing up to 24 minutes of audio.
The technology was later adapted and expanded to include data storage CD-
ROM, write-once audio and data storage CD-R, rewritable media CD-RW, Super
Audio CD (SACD), Video Compact Discs (VCD), Super Video Compact Discs (SVCD),
Module |2 I n p u t / o u t p u t S y s t e m s
109 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Photo CD, Picture CD, CD-i, and Enhanced CD. CD-ROMs and CD-Rs remain widely
used technologies in the computer industry. The CD and its extensions have been
extremely successful: in 2004, worldwide sales of CD audio, CD-ROM, and CD-R
reached about 30 billion discs. By 2007, 200 billion CDs had been sold worldwide.
Physical details
A Compact Disc is made from a 1.2 mm thick disc of almost pure
polycarbonate plastic and weighs approximately 16 grams. A thin layer of aluminium
or, more rarely, gold is applied to the surface to make it reflective, and is protected by
a film of lacquer. The lacquer is normally spin coated directly on top of the reflective
layer. On top of that surface, the label print is applied. Common printing methods for
CDs are screen-printing and offset printing.
CD data is stored as a series of tiny indentations (pits), encoded in a tightly
packed spiral track molded into the top of the polycarbonate layer. The areas between
pits are known as "lands". Each pit is approximately 100 nm deep by 500 nm wide,
and varies from 850 nm to 3.5 µm in length.
The spacing between the tracks, the pitch, is 1.6 µm. A CD is read by focusing a
780 nm wavelength (near infrared) semiconductor laser through the bottom of the
polycarbonate layer. The change in height between pits and lands results in a
difference in intensity in the light reflected. By measuring the intensity change with a
photodiode, the data can be read from the disc.
Main physical parameters
The main parameters of the CD are as follows:
• Scanning velocity: 1.2–1.4 m/s (constant linear velocity) – equivalent to
approximately 500 rpm at the inside of the disc, and approximately 200 rpm at
the outside edge. (A disc played from beginning to end slows down during
playback.)
• Track pitch: 1.6 µm
• Disc diameter 120 mm
• Disc thickness: 1.2 mm
• Inner radius program area: 25 mm
• Outer radius program area: 58 mm
• Center spindle hole diameter: 15 mm
Module |2 I n p u t / o u t p u t S y s t e m s
110 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The program area is 86.05 cm² and the length of the recordable spiral is
(86.05 cm² / 1.6 µm) = 5.38 km. With a scanning speed of 1.2 m/s, the playing time is
74 minutes, or around 650 MB of data on a CD-ROM. If the disc diameter were only
115 mm, the maximum playing time would have been 68 minutes, i.e., six minutes
less. A disc with data packed slightly more densely is tolerated by most players
(though some old ones fail). Using a linear velocity of 1.2 m/s and a track pitch of
1.5 µm leads to a playing time of 80 minutes, or a capacity of 700 MB. Even higher
capacities on non-standard discs (up to 99 minutes) are available at least as recordable,
but generally the tighter the tracks are squeezed the worse the compatibility.
Manufacture
Replicated CDs are mass-produced initially using a hydraulic press. Small
granules of raw polycarbonate plastic are fed into the press while under heat. A screw
forces the liquefied plastic into the mold cavity. The mold closes with a metal stamper
in contact with the disc surface. The plastic is allowed to cool and harden. Once
opened, the disc substrate is removed from the mold by a robotic arm, and a 15 mm
diameter center hole (called a stacking ring) is removed. The cycle time, the time it
takes to "stamp" one CD, is usually 2–3 seconds.
This method produces the clear plastic blank part of the disc. After a metallic
reflecting layer (usually aluminum, but sometimes gold or other metals) is applied to
the clear blank substrate, the disc goes under a UV light for drying and it is ready to
go to press. To prepare to press a CD, a glass master is made using a high-power laser
on a device similar in principle to a CD writer. The glass master is a positive image of
the desired CD surface (with the desired microscopic pits and lands). After testing, it
is used to make a die by pressing it against a metal disc.
The die is a negative image of the glass master: several are typically made,
depending on the number of pressing mills that are to be making the CD. The die then
goes into a press and the physical image is imposed onto the blank CD, leaving a final
positive image on the disc. A small amount of lacquer is then applied as a ring around
the center of the disc, and a fast spin spreads it evenly over the surface. Edge
protection lacquer is also applied before the disk is finished. The disc can then be
printed and packed.
Module |2 I n p u t / o u t p u t S y s t e m s
111 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
DIGITAL VERSATILE DISC (DVD)
DVD (also known as "Digital Versatile Disc" or "Digital Video Disc") is a
popular optical disc storage media format. Its main uses are video and data storage.
Most DVDs are of the same dimensions as compact discs (CDs) but store more than
six times as much data.
Variations of the term DVD often describe the way data is stored on the discs:
DVD-ROM has data which can only be read and not written, DVD-R and DVD+R can
only record data once and then function as a DVD-ROM. DVD-RW and DVD+RW can
both record and erase data multiple times. The wavelength used by standard DVD
lasers is 650 nm, and thus has a red color.
DVD-Video and DVD-Audio discs respectively refer to properly formatted and
structured video and audio content. Other types of DVDs, including those with video
content, may be referred to as DVD-Data discs. As next generation High definition
optical formats also use a disc identical in some aspects yet more advanced than a
DVD, such as Blue-ray Disc, the original DVD is occasionally given the retronym SD
DVD.
READ ONLY MEMORY
Read-only memory (usually known by its acronym, ROM) is a class of storage
media used in computers and other electronic devices. Because data stored in ROM
cannot be modified (at least not very quickly or easily), it is mainly used to distribute
firmware (software that is very closely tied to specific hardware, and unlikely to
require frequent updates).
In its strictest sense, ROM refers only to mask ROM (the oldest type of solid
state ROM), which is fabricated with the desired data permanently stored in it, and
thus can never be modified. However, more modern types such as EPROM and flash
EEPROM can be erased and re-programmed multiple times; they are still described as
"read-only memory" because the reprogramming process is generally infrequent,
comparatively slow, and often does not permit random access writes to individual
memory locations. Despite the simplicity of mask ROM, economies of scale and field-
programmability often make reprogrammable technologies more flexible and
inexpensive, so that mask ROM is rarely used in new products as of 2007.
Module |2 I n p u t / o u t p u t S y s t e m s
112 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Types of ROMs
Classic mask-programmed ROM chips are integrated circuits that physically
encode the data to be stored, and thus it is impossible to change their contents after
fabrication. Other types of non-volatile solid-state memory permit some degree of
modification:
• Programmable read-only memory (PROM), or one-time programmable ROM
(OTP), can be written to or programmed via a special device called a PROM
programmer. Typically, this device uses high voltages to permanently destroy or
create internal links (fuses or antifuses) within the chip. Consequently, a PROM
can only be programmed once.
• Erasable programmable read-only memory (EPROM) can be erased by exposure
to strong ultraviolet light (typically for 10 minutes or longer), then rewritten with a
process that again requires application of higher than usual voltage. Repeated
exposure to UV light will eventually wear out an EPROM, but the endurance of
most EPROM chips exceeds 1000 cycles of erasing and reprogramming. EPROM
chip packages can often be identified by the prominent quartz "window" which
allows UV light to enter. After programming, the window is typically covered
with a label to prevent accidental erasure. Some EPROM chips are factory-erased
before they are packaged, and include no window; these are effectively PROM.
• Electrically erasable programmable read-only memory (EEPROM) is based on a
similar semiconductor structure to EPROM, but allows its entire contents (or
selected banks) to be electrically erased, then rewritten electrically, so that they
need not be removed from the computer (or camera, MP3 player, etc.). Writing or
flashing an EEPROM is much slower (milliseconds per bit) than reading from a
ROM or writing to a RAM (nanoseconds in both cases), since available densities
are not as great and the cost per bit is higher.
o Electrically alterable read-only memory (EAROM) is a type of EEPROM that
can be modified one bit at a time. Writing is a very slow process and again
requires higher voltage (usually around 12 V) than is used for read access.
EAROMs are intended for applications that require infrequent and only
partial rewriting. EAROM may be used as non-volatile storage for critical
system setup information; in many applications, EAROM has been
supplanted by CMOS RAM supplied by mains power and backed-up with a
lithium battery.
Module |2 I n p u t / o u t p u t S y s t e m s
113 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
o Flash memory (or simply flash) is a modern type of EEPROM invented in
1984. Flash memory can be erased and rewritten faster than ordinary
EEPROM, and newer designs feature very high endurance (exceeding
1,000,000 cycles). Modern NAND flash makes efficient use of silicon chip
area, resulting in individual ICs with a capacity as high as 16 GB as of 2007;
this feature, along with its endurance and physical durability, has allowed
NAND flash to replace magnetic in some applications (such as USB flash
drives). Flash memory is sometimes called flash ROM or flash EEPROM
when used as a replacement for older ROM types, but not in applications that
take advantage of its ability to be modified quickly and frequently.
OPTICAL CHARACTER RECOGNITION (OCR)
Optical character recognition, usually abbreviated to OCR, is the mechanical
or electronic translation of images of handwritten, typewritten or printed text (usually
captured by a scanner) into machine-editable text.
OCR is a field of research in pattern recognition, artificial intelligence and
machine vision. Though academic research in the field continues, the focus on OCR
has shifted to implementation of proven techniques. Optical character recognition
(using optical techniques such as mirrors and lenses) and digital character recognition
(using scanners and computer algorithms) were originally considered separate fields.
Because very few applications survive that use true optical techniques, the OCR term
has now been broadened to include digital image processing as well.
Early systems required training (the provision of known samples of each
character) to read a specific font. "Intelligent" systems with a high degree of
recognition accuracy for most fonts are now common. Some systems are even capable
of reproducing formatted output that closely approximates the original scanned page
including images, columns and other non-textual components.
Optical Character Recognition (OCR) is sometimes confused with on-line
character recognition. OCR is an instance of off-line character recognition, where the
system recognizes the fixed static shape of the character, while on-line character
recognition instead recognizes the dynamic motion during handwriting. For example,
on-line recognition, such as that used for gestures in the Penpoint OS or the Tablet PC
Module |2 I n p u t / o u t p u t S y s t e m s
114 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
can tell whether a horizontal mark was drawn right-to-left, or left-to-right. On-line
character recognition is also referred to by other terms such as dynamic character
recognition, real-time character recognition, and Intelligent Character Recognition or
ICR.
On-line systems for recognizing hand-printed text on the fly have become well-
known as commercial products in recent years. Among these are the input devices for
personal digital assistants such as those running Palm OS. The Apple Newton
pioneered this product. The algorithms used in these devices take advantage of the
fact that the order, speed, and direction of individual lines segments at input are
known. Also, the user can be retrained to use only specific letter shapes. These
methods cannot be used in software that scans paper documents, so accurate
recognition of hand-printed documents is still largely an open problem. Accuracy
rates of 80% to 90% on neat, clean hand-printed characters can be achieved, but that
accuracy rate still translates to dozens of errors per page, making the technology
useful only in very limited applications.
Recognition of cursive text is an active area of research, with recognition rates
even lower than that of hand-printed text. Higher rates of recognition of general
cursive script will likely not be possible without the use of contextual or grammatical
information. For example, recognizing entire words from a dictionary is easier than
trying to parse individual characters from script. Reading the Amount line of a cheque
(which is always a written-out number) is an example where using a smaller
dictionary can increase recognition rates greatly. Knowledge of the grammar of the
language being scanned can also help determine if a word is likely to be a verb or a
noun, for example, allowing greater accuracy. The shapes of individual cursive
characters themselves simply do not contain enough information to accurately
(greater than 98%) recognize all handwritten cursive script.
It is necessary to understand that OCR technology is a basic technology also
used in advanced scanning applications. For more complex recognition problems,
intelligent character recognition systems are generally used, as artificial neural
networks can be made indifferent to both affine and non-linear transformations.
Module |2 I n p u t / o u t p u t S y s t e m s
115 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PRINTERS
One of the most commonly used computer peripherals is the printer. a printer
is a peripheral which produces a hard copy (permanent human-readable text and/or
graphics) of documents stored in electronic form, usually on physical print media
such as paper or transparencies. Many printers are primarily used as local peripherals,
and are attached by a printer cable or, in most new printers, a USB cable to a computer
which serves as a document source. Some printers, commonly known as network
printers, have built-in network interfaces (typically wireless or Ethernet), and can
serve as a hardcopy device for any user on the network. Individual printers are often
designed to support both local and network connected users at the same time.
In addition, a few modern printers can directly interface to electronic media
such as memory sticks or memory cards, or to image capture devices such as digital
cameras, scanners; some printers are combined with a scanners and/or fax machines
in a single unit, and can function as photocopiers. Printers that include non-printing
features are sometimes called Multifunction Printers (MFP), Multi-Function Devices
(MFD), or All-In-One (AIO) printers. Most MFPs include printing, scanning, and
copying among their features.
Printers are designed for low-volume, short-turnaround print jobs; requiring
virtually no setup time to achieve a hard copy of a given document. However,
printers are generally slow devices (30 pages per minute is considered fast), and the
cost-per-page is relatively high. The world's first computer printer was a 19th century
mechanically driven apparatus invented by Charles Babbage for his Difference
Engine.
TYPES OF PRINTERS
Impact printers place characters on the page by causing a hammer device to
strike an inked ribbon. The ribbon, in turn, strikes the printing surface (paper).
Several nonimpact methods of printing are used in computer printers. Older,
nonimpact printers relied on special heat-sensitive or chemically reactive paper to
form characters on the page. Newer methods of nonimpact printing use ink droplets,
squirted from a jet nozzle device (ink-jet printers), or a combination of
laser/xerographic print technologies (laser printers) to place characters on a page.
Currently, the most popular nonimpact printers use ink-jet or laser technologies to
deliver ink to the page.
Module |2 I n p u t / o u t p u t S y s t e m s
116 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Basically, there are two methods of creating characters on a page. One method
places a fully shaped and fully filled-in character on the page. This type of character is
called a fully formed character. The other method involves placing dots on the page in
strategic patterns to fool the eye into seeing a character. This type of character is
referred to as a dot-matrix character.
Over time, printer technology has improved so that they can produce photo-
like images. However, a number of printer technologies are still in use, due to cost and
quality differences between them. The three most common printer technologies are
dot matrix, inkjet or bubble jet, and laser.
MODERN PRINT TECHNOLOGY
The following printing technologies are routinely found in modern printers
1. TONER BASED PRINTERS
Toner-based printers work using the Xerographic principle that is used in most
photocopiers: by adhering toner to a light-sensitive print drum, then using static
electricity to transfer the toner to the printing medium to which it is fused with heat
and pressure.
The most common type of toner-based printer is the laser printer, which uses
precision lasers to cause toner adherence. Laser printers are known for high quality
prints, good print speed, and a low (Black and White) cost-per-copy. They are the
most common printer for many general-purpose office applications, but are much less
common as consumer printers due to their high initial cost-although this cost is
dropping. Laser printers are available in both color and monochrome varieties.
LASER PRINTERS
A laser beam projects an image of the page to be printed onto an electrically
charged rotating drum coated with selenium. Photoconductivity removes charge from
the areas exposed to light. Dry ink (toner) particles are then electrostatically picked up
by the drum's charged areas. The drum then prints the image onto paper by direct
contact and heat, which fuses the ink to the paper.
Module |2 I n p u t / o u t p u t S y s t e m s
117 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2. LIQUID INKJET PRINTERS
Inkjet printers operate by propelling variably-sized droplets of liquid or molten
material (ink) onto almost any sized page. They are the most common type of
computer printer for the general consumer due to their low cost, high quality of
output, capability of printing in vivid color, and ease of use.
The emerging ink jet material deposition market also uses ink jet technologies,
typically piezoelectric jets, to deposit materials directly on substrates. The idea is that
because the head need not be replaced every time the ink runs out, consumable costs
can be made lower and the head itself can be more precise than a cheap disposable
one, typically requiring no calibration. On the other hand, if the head is damaged, it is
usually necessary to replace the entire printer.
TECHNOLOGIES
There are three main technologies in use in contemporary inkjet printers:
thermal, piezoelectric, and continuous.
1. Thermal inkjets
Most consumer inkjet printers (Lexmark, Hewlett-Packard, and Canon) use
print cartridges with a series of tiny electrically heated chambers constructed by
photolithography. To produce an image, the printer runs a pulse of current through
the heating elements causing a steam explosion in the chamber to form a bubble,
which propels a droplet of ink onto the paper. The ink's surface tension as well as the
condensation and thus contraction of the vapour bubble, pulls a further charge of ink
into the chamber through a narrow channel attached to an ink reservoir.
The ink used is known as aqueous (i.e. water-based inks using pigments or
dyes) and the print head is generally cheaper to produce than other inkjet
technologies. The principle was discovered by Canon engineer Ichiro Endo in August
1977.
2. Piezoelectric inkjets
Most commercial and industrial ink jet printers use a piezoelectric material in
an ink-filled chamber behind each nozzle instead of a heating element. When a
voltage is applied, the piezoelectric material changes shape or size, which generates a
Module |2 I n p u t / o u t p u t S y s t e m s
118 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
pressure pulse in the fluid forcing a droplet of ink from the nozzle. This is essentially
the same mechanism as the thermal inkjet but generates the pressure pulse using a
different physical principle. Piezoelectric (also called Piezo) ink jet allows a wider
variety of inks than thermal or continuous ink jet but the print heads are more
expensive. Piezo inkjet technology uses stationary heads, which are built with robust
construction and are designed for high volume production, faster print speeds, and
lower costs. There is a drop-on-demand process, with software that directs the heads
to apply between zero to eight droplets of ink per dot and only where needed.
3. Continuous ink jet
The continuous ink jet method is used commercially for marking and coding of
products and packages. The idea was first patented in 1867, by Lord Kelvin and the
first commercial devices (medical strip chart recorders) were introduced in 1951 by
Siemens.
In continuous ink jet technology, a high-pressure pump directs liquid ink from
a reservoir through a gunbody and a microscopic nozzle, creating a continuous stream
of ink droplets via the Plateau-Rayleigh instability. A piezoelectric crystal creates an
acoustic wave as it vibrates within the gunbody and causes the stream of liquid to
break into droplets at regular intervals – 64,000 to 165,000 drops per second may be
achieved. The ink droplets are subjected to an electrostatic field created by a charging
electrode as they form, the field varied according to the degree of drop deflection
desired. This results in a controlled, variable electrostatic charge on each droplet.
Charged droplets are separated by one or more uncharged “guard droplets” to
minimize electrostatic repulsion between neighbouring droplets.
The charged droplets pass through an electrostatic field and are directed
(deflected) by electrostatic deflection plates to print on the receptor material
(substrate), or allowed to continue on undeflected to a collection gutter for re-use. The
more highly charged droplets are deflected to a greater degree. Only a small fraction
of the droplets is used to print, the majority being recycled.
Continuous ink jet is one of the oldest ink jet technologies in use and is fairly
mature. One of its advantages is the very high velocity (50 m/s) of the ink droplets,
which allows for a relatively long distance between print head and substrate. Another
advantage is freedom from nozzle clogging as the jet is always in use, therefore
allowing volatile solvents such as ketones and alcohols to be employed, giving the ink
the ability to "bite" into the substrate and dry quickly.
Module |2 I n p u t / o u t p u t S y s t e m s
119 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The ink system requires active solvent regulation to counter solvent
evaporation during the time of flight (time between nozzle ejection and gutter
recycling) and from the venting process whereby air that is drawn into the gutter
along with the unused drops is vented from the reservoir. Viscosity is monitored and
a solvent (or solvent blend) is added in order to counteract the solvent loss.
Advantages of Inkjet Printer: Compared to earlier consumer-oriented colour printers,
inkjets have a number of advantages. They are quieter in operation than impact dot
matrix or daisywheel printers. They can print finer, smoother details through higher
printhead resolution, and many consumer inkjets with photographic-quality printing
are widely available.
In comparison to more expensive technologies like thermal wax, dye
sublimations, and laser printers, inkjets have the advantage of practically no warm up
time and lower cost per page (except when compared to laser printers).
Disadvantages of Inkjet Printer: Inkjet printers may have a number of disadvantages
1. The ink is often very expensive. (For a typical OEM cartridge priced at $15,
containing 5 mL of ink, the ink effectively costs $3000 per liter--or $8000 per
gallon.)
2. Many "intelligent" ink cartridges contain a microchip that communicates the
estimated ink level to the printer; this may cause the printer to display an error
message, or incorrectly inform the user that the ink cartridge is empty. In some
cases, these messages can be ignored, but some inkjet printers will refuse to print
with a cartridge that declares itself empty, in order to prevent consumers from
refilling cartridges.
3. The lifetime of inkjet prints produced by inkjets using aqueous inks is limited; they
will eventually fade and the color balance may change. On the other hand, prints
produced from solvent-based inkjets may last several years before fading, even in
direct sunlight, and so-called "archival inks" have been produced for use in
aqueous-based machines which offer extended life.
4. Because the ink used in most consumer inkjets is water-soluble, care must be taken
with inkjet-printed documents to avoid even the smallest drop of water, which can
cause severe "blurring" or "running." Similarly, water-based highlighter markers
can blur inkjet-printed documents.
Module |2 I n p u t / o u t p u t S y s t e m s
120 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
3.DOT-MATRIX PRINTERS
A dot matrix printer or impact matrix printer is a type of computer printer
with a print head that runs back and forth on the page and prints by impact, striking
an ink-soaked cloth ribbon against the paper, much like a typewriter. Unlike a
typewriter or daisy wheel printer, letters are drawn out of a dot matrix, and thus,
varied fonts and arbitrary graphics can be produced. Because the printing involves
mechanical pressure, these printers can create carbon copies and carbonless copies.
Each dot is produced by a tiny metal rod, also called a "wire" or "pin", which is
driven forward by the power of a tiny electromagnet or solenoid, either directly or
through small levers (pawls). Facing the ribbon and the paper is a small guide plate
(often made of an artificial jewel such as sapphire or ruby) pierced with holes to serve
as guides for the pins. The moving portion of the printer is called the print head, and
when running the printer as a generic text device generally prints one line of text at a
time. Most dot matrix printers have a single vertical line of dot-making equipment on
their print heads; others have a few interleaved rows in order to improve dot density.
These machines can be highly durable. When they do wear out, it is generally
due to ink invading the guide plate of the print head, causing grit to adhere to it; this
grit slowly causes the channels in the guide plate to wear from circles into ovals or
slots, providing less and less accurate guidance to the printing wires. Eventually, even
with tungsten blocks and titanium pawls, the printing becomes too unclear to read.
Although nearly all inkjet, thermal, and laser printers produce dot matrices, in
common parlance these are seldom called "dot matrix" printers, to avoid confusion
with dot matrix impact printers.
Dot matrix printers can either be character-based or line-based (that is, a single
horizontal series of pixels across the page), referring to the configuration of the print
head. Dot matrix printers were one of the more common types of printers used for
general use - such as for home and small office use. Such printers would have either 9
or 24 pins on the print head. 24-pin print heads were able to print at a higher quality.
Once the price of inkjet printers dropped to the point where they were competitive
with dot matrix printers, dot matrix printers began to fall out of favor for general use.
Module |2 I n p u t / o u t p u t S y s t e m s
121 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
BIOMEDICAL ENGINEERING
Biomedical engineering (BME) is the application of engineering principles and
techniques to the medical field. It combines the design and problem solving skills of
engineering with medical and biological sciences to help improve patient health care
and the quality of life of individuals.
MEDICAL DEVICES
A medical device is an object which is useful for diagnostic or therapeutic
purposes. Examples of medical devices include medical thermometers, blood sugar
meters, and X-ray machines.
Definition : A medical device as any instrument, apparatus, appliance, software,
material or other article, whether used alone or in combination, including the software
intended by its manufacturer to be used specifically for diagnostic and/or therapeutic
purposes and necessary for its proper application, intended by the manufacturer to be
used for human beings. Devices are to be used for the purpose of:
• Diagnosis, prevention, monitoring, treatment or alleviation of disease.
• Diagnosis, monitoring, treatment, alleviation of or compensation for an injury
or handicap.
• Investigation, replacement or modification of the anatomy or of a physiological
process
• Control of conception
This includes devices that do not achieve its principal intended action in or on the
human body by pharmacological, immunological or metabolic means, but which may
be assisted in its function by such means.
List of medical devices
a. High risk devices
High risk devices are life supports, critical monitoring, energy emitting and other
devices whose failure or misuse is reasonably likely to seriously injure patient or staff.
Examples includes
• Anesthesia ventilators
• Anesthesia units
• Electrosurgical units
• Incubators
• Pulse oximeters
• External pacemaker
• Heart Lung Machine etc.
Module |2 I n p u t / o u t p u t S y s t e m s
122 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
b. Medium risk devices
These are devices including many diagnostic instruments whose misuse, failure or
absence (e.g. out of service with no replacement available would have a significant
impact on patient care, but would not be likely to cause direct serious injury.
Examples are
• ECG
• EEG
• Ultrasound sensors
• Phototherapy units
• Phonocardiograph’s etc.
c. Low risk devices
Devices in this category are those whose failure or misuse is unlikely to result in
serious consequences. Some examples for such equipments include
• Electronic thermometer,
• Breast pumps
• Surgical microscope
• Sphygmomanometers
• Surgical table
• Surgical lights.
• Temperature monitor
• X-rays diagnostic equipment etc.
ARTIFICIAL INTERNAL ORGANS
An artificial organ is a man-made device that is implanted into, or integrated
onto, a human to replace a natural organ, for the purpose of restoring a specific
function or a group of related functions so the patient may return to as normal a life as
possible. The replaced function doesn't necessarily have to be related to life support,
but often is.
Reasons to construct and install an artificial organ, an extremely expensive
process initially, which may entail many years of ongoing maintenance services not
needed by a natural organ, might include:
• Life support to prevent imminent death while awaiting a transplant (e.g.
artificial heart)
• Dramatic improvement of the patient's ability for self care (e.g. artificial limb)
• Improvement of the patient's ability to interact socially (e.g. cochlear implant)
• Cosmetic restoration after cancer surgery or accident
Module |2 I n p u t / o u t p u t S y s t e m s
123 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Some of the artificial internal organs are
Pacemakers
Artificial Heart Valves
Heart Lung Machine
I. PACEMAKERS
Pacemaker is an electrical pulse generator for starting and/or maintaining the
normal heart beat. The output of the pacemaker is applied either externally to the
chest or internally to the heart muscle. In the case of cardiac stand still, the use of the
pacemaker is temporary - just long enough to start a normal heart rhythm. In case's
requiring long term pacing, the pacemaker is surgically implanted in the body and its
electrodes are in direct contact with the heart. In cardiac diseases, where the
ventricular rate is too low, it can be increased to normal rate by using pacemaker. The
various arrhythmias (rhythm disturbances) that result in heart block and Adams
stokes attacks represent a serious pathological condition. During that time, the patient
becomes invalid because of the constant risk of sudden losing consciousness. By fixing
the artificial electronic pacemakers, the above defects in the heart can be eliminated.
With conventional drug therapy, the failure within a year is about 50%. Pacemaker
therapy lowers this figure to 15% and leads to a considerable improvement in the
patient’s mental and physical wellbeing.
Methods of stimulation
There are two types of stimulation or pacing: External stimulation and Internal
stimulation. External stimulation is employed to restart the normal rhythm of the
heart in the case of cardiac stand still. Stand still can occur during open heart surgery
or whenever there is a sudden physical shock or accident. The paddle shaped
electrodes are applied on the surface of the chest and currents in the range of 20 – 150
mA are employed. Internal stimulation is employed in cases requiring long term
pacing because of permanent damage that prevents normal self triggering of the heart.
The electrodes are in the form of fine wires of Teflon coated stainless steal. In some
cases, during restarting of the heart after open heart surgery, spoon like electrodes are
used. The currents in the range of 2 – 15 mA are employed. The bipolar and unipolar
electrodes are used. In the bipolar electrode, there are stimulating electrode and
contact electrode which serves as a return path for current to the pacemaker. In the
unipolar electrode, there is only stimulating electrode and the return path for current
to the pacemaker is made through body fluids.
Module |2 I n p u t / o u t p u t S y s t e m s
124 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Even though the internal stimulation is adopted in most cases, based on the
placement of the pacemaker; there are two types, external pacemaker and implanted
pacemaker.
No. External pacemaker
Implanted pacemaker
(internal pacemaker)
1.
The pacemaker is placed outside the
body. It may be in the form of wrist
watch or in the pocket, from that one
wire will go into the heart through the
vein.
The pacemaker is miniaturized and is
surgically implanted beneath the skin
near the chest or abdomen with its
output leads are connected directly to
the heart muscle.
2.
The electrodes are called endocardiac
electrodes and are applied to the heart
by means of an electrode catheter with
electrode’s tip situated in the apex of
the right ventricle. These are in
contact with the inner surface of the
heart chamber.
The electrodes are called myocardiac
electrodes and are in contact with the
outer wall of the myocardium (heart
muscle). Endocardiac electrodes are
also used.
3. It does not necessitate the open chest
surgery.
It requires an open chest minor
surgery to place the circuit.
4.
The battery can be easily replaced and
any defect or adjustment in the circuit
can be easily attended without getting
any help from a medical doctor.
The battery can be replaced only by
minor surgery. Further any defeat or
adjustment in the circuit cannot be
easily attended. Doctor’s help is
necessary to rectify the defeat in the
circuit.
5.
During placement, swelling and pain
do not arise due to maintain foreign
body reaction.
During placement swelling and pain
arise due to foreign body reaction.
6.
Here there is no safety for the
pacemaker particularly in the case of
children carrying the pacemaker.
Here there is a cent percent safety for
the circuit from the external
disturbances.
7. Mostly these are used for temporary
heart irregularities.
Mostly these are used for permanent
heart irregularities.
Module |2 I n p u t / o u t p u t S y s t e m s
125 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
II. ARTIFICIAL HEART VALVES
An artificial heart valve is a device which is implanted in the heart of patients
who suffer from valvular diseases in their heart. When one or two of the four heart
valves (human heart contains four valves: tricuspid valve, pulmonic valve, mitral
valve and aortic valve) of the heart have a malfunction, the choice is normally to
replace the natural valve with an artificial valve. This requires open-heart surgery.
Valves are integral to the normal physiological functioning of the human heart.
Natural heart valves are structures which have evolved a form which meets their
functional requirements, which is to induce largely unidirectional flow through
themselves. Natural heart valves may become dysfunctional due to a variety of
pathological causes. Certain heart valve pathologies may necessitate the complete
surgical replacement of the natural heart valves with heart valve prostheses.
Different Natural Heart Valves
Since the left side of the heart is the one which normally functions with much
higher pressure differentials, the left heart valves are usually failed to function
properly. The mitral valve is located between the left atrium and the left ventricle and
the aortic valve is located between the left ventricle and aorta. Occasionally the
tricuspid valve which is located between the right ventricle and right atrium will fail.
The procedure in valve replacement involves opening the chest (thoracotomy),
placing the heart on bypass using a heart-lung machine, cutting through the heart
muscle to expose the valve, excising the diseased valve and the surrounding tissue
and attaching a prosthetic valve in its place.
Different Types of Artificial Heart Valves
Most of the artificial heart valves are check valves of the caged-ball
(Scandanavian type) or caged-disc (Alaskan type) variety. The ball or disc is made
from silicone rubber. A metal ring surrounded by either Dacron or Teflon forms the
connecting surface which is sewn to the natural seat from which the pathologic valve
is removed. Starr and Edwards devised a mitral valve using a ball made of silastic 372
Module |2 I n p u t / o u t p u t S y s t e m s
126 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
rubber (Figure (a)). The Starr-Edwards aortic valve has large orifice and small
regurgitation. It has large opening resistance. The closure of that valve is in a very
slow manner. The Magovern-Cromie aortic valve (Figure (b )) differs from others such
that there is a series of needle like projections which are screwed out during the
installation procedure. These attach themselves to the ring of tissue around the valve
and form the fixation. Its main advantage is that time consuming sewing of the valve
to the tissue is eliminated and the operation can be performed in much less time. In
the Kay Shiley mitral valve (Figure (c)) a caged disc replaces the silastic ball. This type
is anatomically more suitable than other types. Gott butterfly mitral valve (Figure (d))
has quick opening and closing and large orifice. It has a disadvantage that it has great
regurgitation. Similarly the leaflet valve (Figure (e)) used as mitral valve has the same
functioning of Gott butterfly valve. Now-a-days the ball or disc is made of hollowed
solid polymers (polypropylene, polyoxymethylene, polychlorotrifluro ethylene, etc.),
metals (titanium and vitallium alloys) and pyrolytic carbon.
Module |2 I n p u t / o u t p u t S y s t e m s
127 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
III. HEART-LUNG MACHINE
During open heart surgery for installation of a valve prosthesis or correction of
a congenital mal function, the heart cannot maintain the circulation. It is then
necessary to provide extra-corporeal circulation with a special machine called heart
lung machine. Further this is also used to provide circulatory assistance to support a
faulty heart. While doing open heart surgery, it is necessary to bypass the heart to
enable the surgeon to work in a bloodless field under direct vision. The heart-lung
machine replaces the functions of heart and lungs thereby providing the rest of the
body with a continuous supply of oxygenated blood while the heart is stopped.
Eventhough the heart is to be bypassed for the repair itself, for technical reasons both
the heart and lungs are bypassed by present day methods.
Mechanical Functions of the Heart
i. In an intact heart, venous or unoxygenated blood is returned to the right side of
the heart at a pressure of 0 to 5 mm Hg and oxygen saturation below 75%.
ii. From the right side of the heart, the blood is pumped into lungs through
pulmonary arteries.
iii. In the lungs the blood is oxygenated to about 95 to 98% saturation and then it is
going to the left atrium of the heart, which acts as a receiving chamber.
iv. From there, the blood flows into the left ventricle through the mitral valve. The
left ventricle is called the more powerful chamber of the heart.
v. The ventricle ejects the blood into the aorta with peak pressures ranging from
100 to 150 mm Hg.
vi. Since the contraction of the left ventricle is rhythmic, the resultant flow in the
aorta is pulsatile, reaching a systolic peak pressure of about 90 to 140 mm Hg
with 120 mm Hg as the mean and a low point or diastolic of about 60 to 90 mm
Hg with 80 mm Hg as the mean. Systole is the period of contraction of the
ventricular muscles during that time blood is pumped into the pulmonary
artery and the aorta. Diastole is the period of dilation of the heart chambers as
they fill with blood.
vii. The heart pumps about 5 liters of blood per minute. At any time, the veins
contain 75 to 80% of the blood volume and arteries contain 20 to 25% of blood
volume.
viii. The pressures in different areas of the heart are given as follows:
Module |2 I n p u t / o u t p u t S y s t e m s
128 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Following figure shows the systematic cardiovascular circulation procedure.
All the arteries, (except pulmonary artery) carry pure blood from heart to different
parts of the body. Similarly all the veins (except pulmonary vein) carry the impure
blood from different parts of the body to the heart.
Fig: Systematic Cardiovascular circulation
Module |2 I n p u t / o u t p u t S y s t e m s
129 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
THERAPEUTIC ELECTROMECHANICAL DEVICES (EMD’s)
Therapeutic EMD’s are those instruments which are used for the treatment of
human diseases. Widely used Therapeutic EMD’s are Kidney Machine, Ventilators,
and Anesthesia Machine.
I. KIDNEY MACHINE
Kidney machine is an equipment used a s a substitute for a kidney. Although
hemo dialysis, a process for removing impurities from blood was first achieved in
1944, a clinically useful device was developed only in 1960 by B.H.Scribner and his
group.
Renal function
The natural kidneys in our body are used to eliminate the waste products
formed during bodily metabolism and regulate the concentration of the body fluid
constituents. Eventhough there are two kidneys in each body, a single kidney is
capable of clearing all waste products in the blood. Figure shows the formation of
urine from blood by the smallest functional units of the kidneys, called nephrons. The
urine is formed by three processes, namely, filtration of blood plasma, active
secretion of urea, uric acid and phosphates and reabsorption of water, glucose and
sodium chloride so that they are restored to the blood. Each kidney contains about 1
to 1.25 million nephrons. Each nephron consists of a glomerulus which has done the
filtration and several tubeles which have done the active secretion and reabsorption.
Arterial blood is entering into the glomerulus where filtration takes place.
Fig: Formation of urine from blood by nephrons
Module |2 I n p u t / o u t p u t S y s t e m s
130 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Water, glucose, amino acid, salts, low molecular weight protein, urea, uric acid
and creatinine are filtered out. The process of reabsorption takes place at the entrance
of the proximal tube (tubele) where glucose, amino acid, protein, water and salt are
chiefly reabsorbed. Under elevated concentration of a particular chemical in the blood,
the reabsorption by the tubeles is not complete. For example, in the case of diabetes,
the blood sugar level exceeds about 9 mmol/litre, the glucose appears in the urine.
Since the urine reflects the composition of the blood plasma, urinalysis is used in the
diagnosis of diseases that are accompanied by metabolic disorders. In the case of renal
damage, the plasma creatinine (nitrogen containing substances) level in the urine is
reduced below 7-14 millimol/day. Similarly urea level in the urine is also decreased in
the case of renal failure.
In the case of complete renal failure, uremia is developed. During that time,
most of the metabolic breakdown products cannot be excreted and they collect in the
body itself. Thus the urea and creatinine levels in the blood are increased. By that way
the acid-base balance in the body is upset and acidosis is developed. Because of
acidosis, the amount of potassium in the extra cellular fluid increases and this increase
in potassium may affect the heart function. Within few weeks, the death may occur.
The advanced renal failure may be due to inflammation of the kidneys, obstruction of
urine by stones or tumors, poisoning by organic and inorganic chemicals. Intermittent
treatment with a mechanical device, called artificial kidney will reduce the
accumulation of waste products and water in the body.
II. VENTILATORS
A medical ventilator may be defined as an automatic machine designed to
mechanically move breathable air into and out of the lungs, to provide the mechanism
of breathing for a patient who is physically unable to breathe, or breathing
insufficiently. Ventilators are chiefly used in intensive care medicine, home care, and
emergency medicine (as standalone units) and in anesthesia (as a component of an
anesthesia machine).
As a part of intensive care, the patients often require assistance with breathing.
When artificial ventilation is required for a long time, a ventilator is used to provide
oxygen enriched, medicated air to a patient at a controlled temperature. Ventilators
can operate in different modes: Controlled breathing where breathing is initiated by a
timing mechanism and Assisted breathing or patient initiated breathing. Controlled
breathing is an automatically timed breathing which is usually provided for patients
who cannot breathe on their own. It provides inspirations and expirations at fixed
Module |2 I n p u t / o u t p u t S y s t e m s
131 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
rates except during the rest period for the patient. In the case of assisted breathing, the
patient's own spontaneous attempt to breathe in, causes the ventilator to cycle on
during inspiration. Thus it is used for the patient who has difficult breathing due to
high air way resistance. There are servo controlled ventilators which can switch
automatically to any mode depending upon the condition of the patient. This type of
mode is called assist-control mode. By this mode, the patient controls his own
breathing as long as he can, but if he should fail to do so, the control mode is able to
take over for him.
The ventilator treatment gives the following:
a) Adequate ventilation by which enough oxygen is supplied and the right
amount of carbon dioxide is eliminated. Thus hyperventilation which creates
respiratory alkalosis and hypoventilation which creates respiratory acidosis are
avoided.
b) Elimination of respiratory work
c) Increased intrathoracic pressure which prevents atelectasis that is collapse of
portions of the lung and counteracts edema of the lung.
Every ventilator operates cyclically. During insufflation or inspiration air or some
other gaseous mixture is pumped into the lungs. During expiration the pressure
ceases. This cycle is regulated by a mechanical, pneumatic or electronic circuit. The
regulation is obtained by pressure limited, volume limited and servo-controlled
systems.
i) Pressure limited ventilators
Pressure limited ventilators are based on the principle that the insufflation is
terminated when the gaseous mixture pumped into the patient's lungs reaches a pre-
set pressure. Pressure-limited ventilators are driven by the compressed gaseous
mixture used for ventilation. These are so simple in design and reliable in operation.
Below figure shows the pressure limited ventilator system.
ii) Volume limited ventilators
Volume limited ventilators are based on the principle that for each breath, a constant
volume of air is delivered. During insufflation, the constant volume of air is sent into
the lungs by applying pressure to a chamber containing constant volume. The volume
limited ventilators do not give the desired ventilation in cases where the pre-set
maximum pressure cannot completely empty the chamber.
iii) Servo-controlled ventilators
This is based on the usage of modern electronic control techniques such that the
flow to and from the patient is controlled by feedback circuits. The electronic unit
Module |2 I n p u t / o u t p u t S y s t e m s
132 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
controls the amplifiers and logic circuits that control the ventilation. It also monitors
pressures, activates alarms and computes mechanical lung parameters.
Fig: Block diagram of a ventilator with its accessories
III. ANESTHESIA MACHINE
The anesthetic machine (or anesthesia machine) is used by anesthesiologists to
support the administration of anesthesia. The most common type of anesthetic
machine in use in the developed world is the continuous-flow anesthetic machine,
which is designed to provide an accurate and continuous supply of medical gases
(such as oxygen and nitrous oxide), mixed with an accurate concentration of
anesthetic vapour (such as isoflurane), and deliver this to the patient at a safe pressure
and flow. Modern machines incorporate a ventilator, suction unit, and patient-
monitoring devices.
Module |2 I n p u t / o u t p u t S y s t e m s
133 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The original concept was invented by the British anesthetist H.E.G. Boyle in
1917. Prior to this time, anesthetists often carried all their equipment with them, but
the development of heavy, bulky cylinder storage and increasingly elaborate airway
equipment meant that this was no longer practical for most circumstances. The
anesthetic machine is usually mounted on anti-static wheels for convenient
transportation.
Fig: Anesthesia Machine
The above figure shows the block diagram of an anesthesia machine. It
corresponds to the modern partial rebreathing system. The most commonly used
anesthetic is nitrous oxide used in combination with fluorocarbons, such as halothene,
enflurance, methoxyflurane, etc. and oxygen. These are nonflammable. This mixture is
delivered to the patient on the inspiration cycle. The flow rate is correctly maintained
by the flow meters in the each gas tubing. Exhalation passes through a one way valve,
through a CO2 absorber and is delivered to again to the patient. The anesthetic is
constantly monitored and adjusted for the correct mixture by means of controlling
circuits using flow meters like turbine flow meter or rotameter. A portion of the
anesthetic is exhausted and usually delivered to the outside through vent ducts.
During the supply of anesthesia, the respiration and blood circulation should
be monitored even though the supplied anesthesia is very small.
Module |2 I n p u t / o u t p u t S y s t e m s
134 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
DIAGNOSTIC ELECTROMECHANICAL DEVICES (EMD’s)
Diagnostic instruments, as the name itself implies finds the application in
finding disease conditions. In medicine, diagnosis has two distinct dictionary
definitions. The first definition is "the recognition of a disease or condition by its
outward signs and symptoms", while the second definition is "the analysis of the
underlying physiological/biochemical cause(s) of a disease or condition".
Simply put, it is the process of identifying a medical condition or disease by its
signs, symptoms, and from the results of various diagnostic procedures. The
conclusion reached through this process is called a diagnosis. Usually Pulmonary
Function Analysers are used as a Diagnostic EMD in Biomedical engineering.
PULMONARY FUNCTION ANALYSERS
Pulmonary function analysers are used to evaluate the state of the lungs or the
respiratory process. Clinically three basic types of measurements are performed.
Ventilation, distribution and diffusion.
Ventilation
Ventilation deals with the determination of the ability of the body to displace
air volume quantitatively and the speed with which it moves the air. Mostly
spirometers are used in the ventilation measurements.
Distribution
Distribution measurements indicate the degree of lung obstructions for the
flow of air and also determine the residual volume of air that cannot be removed from
the lungs. Pneumotachometers are used to measure the instantaneous rate of volume
flow of respired gases.
Diffusion
Diffusion measurements indicate the lung ability to exchange gas with the
circulatory system, or the rate at which gas is exchanged with the blood stream. Gas
analysers are used in the diffusion measurements.
Module |2 I n p u t / o u t p u t S y s t e m s
135 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
LUNG VOLUMES AND CAPACITIES
All the pulmonary function analysers are used to determine the lung volumes
and capacities. These parameters depend on the individual’s physical characteristics
and the condition of his/her breathing mechanism.
Fig: Lung volumes and capacities
Figure shows the lung volumes and capacities. The lung capacities are
indicated by milliliters and the volumes are indicated by percentages.
i. The total lung capacity (TLC) is the amount of gas contained in the lungs at the
end of a maximal inspiration. As in figure, it is the sum of the vital capacity
(VC) and residual volume (RV).
ii. During inspiration the lung volume is increased and during expiration, it is
decreased. Thus the vital capacity (VC) is the maximum volume of gas that can
be expelled from the lungs after a maximal inspiration. The tidal volume (TV)
is the volume of gas inspired or expired during each normal, quiet and
respiration cycle.
iii. The residual volume (RV) is the volume of gas remaining in the lungs at the
end of a maximal expiration. Inspiratory reserve volume (IRV) is the extra
volume of gas that can be inspired with maximal effort after reaching the
normal end of inspiratory level. Expiratory reserve volume (ERV) is the extra
Module |2 I n p u t / o u t p u t S y s t e m s
136 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
volume of gas that can be expired with maximum effort beyond reaching the
normal end of expiratory level.
iv. Inspiratory capacity (IC) is the maximum amount of gas that can be inspired
after reaching the end expiratory level. Functional residual capacity (FRC) is
the volume of gas remaining in the lungs at the end of expiratory level.
v. There are some forced breathing tests which are used to assess the muscle
power associated with breathing and the resistance of the airway like forced
vital capacity (FVC), which is the total amount of air that can forcibly be
expired as quickly as possible after taking the deepest possible breath and
forced expiratory volume (FEV) which is the maximum amount of gas that can
be expelled in a given time.
SPIROMETER
Already the use of the spirometer is discussed in the Ventilators. Spirometer is
mainly used to measure the respiratory volume measurements. Thus with the aid of
spirometer, all lung volumes and capacities can be determined by measuring the
amount of gas inspired or expired under a given set of conditions or during a given
time interval. In the ventilator, the spirometer with cylinder – piston has been
discussed.
Fig: Spirometer
Module |2 I n p u t / o u t p u t S y s t e m s
137 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Figure shows an electrical spirometer. It consists of light weight bellows. Due
to light weight, there is no airway resistance error. These bellows are mechanically
articulated to a biased potentiometer such that the wiper arm voltage is proportional
to volume, VOL of the bellows. The maximum volume of the bellows in the
spirometer in the spirometer is given by
2max r L VOL π=
If α is the proportionality constant giving the fractional position of the wiper arm on
the potentiometer ‘R’ such that
maxBB
out
VOL
VOL
V
V α ==
max
BB
out VOL V
V VOL =∴
Thus one can get better linearity in measuring respiratory volumes, provided the
indicator (voltmeter) should have better linearity over the desired volume. Normally a
mouthpiece is provided with a spirometer along with the connecting tube.
REFERENCES
1) Mechatronics - W. Bolton
2) Mechatronics - Ganesh S. Hegde
3) Control Systems and Mechatronics - J.Srinivas
4) Biomedical Instrumentation - Dr. M. Arumugam
5) Mechatronics - Dan S. Necsuleseu
6) Understanding Electro Mechanical Engineering - Lawrence J. Kamm
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
138 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MODULE - 3
Introduction to control SYSTEMS engineering
CONTROL SYSTEM
Control system is a system in which the output quantity is controlled by
varying the input quantity. The output quantity is called controlled variable or
response and the input quantity is called command signal or excitation.
The primary objective of any control system is to maintain the response of a
process at a desired value. For example, we want to maintain the level at a desired
value by controlling the inflow rate by adjusting valve opening.
Fig: Liquid level Control System
The control system compares the desired level (set point) with the present level
(controlled variable). The present level is obtained by a sensor (here Level Sensor). If
any difference (error) between set point and controlled variable, the controller takes
the necessary action to increase or decrease the valve opening. This was shown below
as a block diagram.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
139 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
This type of control system is called Closed Loop Control System (feed back
control system). It is also called Automatic Control System. The sensitivity of the
closed loop system may be made small to make the system more stable.
Another division of control system is Open Loop Control System. Any system which
does not automatically correct the variation in its output is called an open loop
system. That is the output has no effect on its input.
In open loop system the output can be varied by varying the input. In open
loop systems the changes in output are corrected by changing the input manually.
TYPES OF CONTROL SYSTEMS
Broadly control system can be classified as
1. Open Loop System and
2. Closed Loop System
OPEN LOOP SYSTEM
A system in which the output is dependent on input but input is totally
independent of the output or changes in output of the system, is called an open loop
system. That is any physical system which does not automatically correct for variation
in its output, is called an open loop system. Such a system may be represented by the
block diagram of figure.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
140 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Reference input, r(t) is applied to the controller which generates the actuating
signal (u) required to control the process which is to be controlled. Process is giving
out the necessary desired controlled output c(t).
Usual case there will be no variation in output for a particular input. We can
say for a given input the desired output is obtained. But if disturbances are occurred
in between the controller and process, the output varies. Such an open loop system is
shown below.
Here the controller output will force the system to give the desired response.
Because of the disturbances present in the system, the output may or may not equal to
the desired response. It can be described on the basis of an example shown in figure.
Here the driver wants to drive the car at 80 Km/hr. To achieve the desired
speed, he applies required pressure on the accelerator pedal and the car starts moving
in the desired speed. But after some time due to disturbances like wind velocity and
road conditions, the speed of the car deviated from the desired speed. The car does
not run at the desired speed even though there is no change in the pressure applied to
accelerator pedal. The distinguished characteristic of an open loop system is that it
cannot compensate or take corrective action for any disturbances that affect the
system performance.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
141 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
CLOSED LOOP SYSTEM
A system in which the controlling action or input is somehow dependent on
the output or changes in output is called closed loop system. To have dependence of
input on the output, such system uses the feedback property. Feedback is a property
of the system by which it permits the output to be compared with the reference input
to generate the error signal based on which the appropriate controlling action can be
decided. In such system, output or part of the output is feedback to the input for
comparison with the reference input applied to it. Closed loop system can be
represented as shown in figure.
Here the output response (controlled variable) is measured and compared with
the desired value (set point) and the deviation is given to the controller. The controller
generates the manipulated variable that minimizes the deviation between the desired
response and controlled response. If there is no difference between the desired value
and measured value, the error signal becomes zero and the controller does not take
any corrective action and the output of the controlled system is maintained at the
desired response. Usually the output value changes due to external disturbances. In
closed loop systems, the information about the instantaneous state of the output is
feedback to the input and is used to modify it in such a manner as to achieve the
desired output.
The action of a man walking from a starting point to destination point along a
prescribed path is an example for closed loop feedback control systems. Here the
reference input is prescribed path. The eye performs the function of sensor. Brain
compares the actual path of movement with prescribed path and generates an error
signal. Then it amplifies the error signal and transmits a control signal to the legs to
correct the actual path of movement to the desired path.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
142 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Driving a car at the desired speed is another example for closed loop control.
Here the driver compares the speed of the car with the desired speed. If he finds any
deviation in speed from the desired speed due to some disturbances then he may
increase or decrease the speed by increasing or decreasing the pressure on the
accelerator pedal so that the deviation becomes zero. In this case the pressure applied
on the accelerator pedal is manipulated variable or control variable.
Comparison between Open Loop and Closed Loop Control System
Open Loop Control System Closed Loop Control System
1 Simple and economical Complex and Costlier
2 Open loop system are stable Closed loop system are unstable
3 Inaccurate and unreliable Accurate and reliable
5
Open loop systems are affected by
noise
Closed loop systems are less affected
by noise
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
143 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
AUTOMATIC CONTROL SYSTEM
Automatic control systems are a special case of closed loop control systems. Let
us investigate the control aspect of the steering mechanism of an automobile (engine
vehicle). The error between the actual and desired directions of the automobile is
given to the controller (Here steering mechanism). The driver senses this error by
tactile means (body movement) and by visually.
Fig: The driver uses the difference between the actual and desired
direction of travel to adjust the steering wheel accordingly
Additional information is available to the driver from the feel (sensing) of the
steering wheel through his hands, these information’s constitute the feedback signals
which are interpreted by driver's brain, who then signals his hand to adjust the
steering wheel accordingly. This again is an example of a closed loop system where
human visual and tactile measurements constitute the feedback loop. It is shown as a
block diagram (given below).
Fig : Automatic Steering Control System
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
144 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Usually closed loop systems involve continuous manual control by a human
operator. So they are also called manually controlled systems. In many complex and fast-
acting systems, the presence of human element in the control loop is undesirable
because the system response may be too rapid for an operator to follow or the
demand on operator's skill may be unreasonably high. Furthermore, some of the
systems e.g., missiles, are self destructive and in such systems human element must be
excluded. Even in situations where manual control could be possible, an economic
case can often be made out for reduction of human supervision. Thus in most
situations the use of some equipment which performs the same intended function as a
continuously employed human operator is preferred. A system incorporating such
equipment is known as automatic control system. In fact in most situations an automatic
control system could be made to perform intended functions better than a human
operator, and could further be made to perform such functions as would be
impossible for a human operator.
The general block diagram of an automatic control system which is
characterized by a feedback loop is shown in figure. An error detector compares a
signal obtained through feedback elements, which is a function of the output
response, with the reference input. Any difference between these two signals
constitutes an error or actuating signal, which actuates the control elements. The
control elements in turn alter the conditions in the plant (controlled member) in such a
manner as to reduce the original error.
Fig : General block diagram of an Automatic Control System
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
145 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
SERVO MECHANISMS
Servomechanisms are feedback control systems in which the output is
mechanical position (or time derivatives of position, example velocity and
acceleration). Such a servomechanism is shown in figure.
Fig: Position Control System
It is also called position control system. It consists of a servomotor powered by
a generator. The load whose position has to be controlled is connected to motor shaft
through gear wheels. Potentiometers are used to convert the mechanical motion to
electric signals. The desired load position (QR) is set on the input potentiometer and
the actual load position (QC) is fed to feedback potentiometer. The difference between
the two angular positions generates an error signal, which is amplified and fed to
generator field circuit. The induced emf of the generator drives the motor. The
rotation of the motor stops when the error signal is zero, i.e. when the desired load
position is reached.
Few other examples of servomechanism are,
1. Power steering apparatus for an automobile.
2. Machine tool position control.
3. Missile launchers.
4. Roll stabilization of ships.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
146 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
TRANSFER FUNCTION
For analysis and design, control systems are usually described by a set of
different equations. The inter relationships of the equations can be pictorially shown
as a block diagram. Each component of the block is described by transfer function. In
actual size, the transfer function is mathematically defined as the ratio of Laplace
transform of the output component to the Laplace transform of the input with all
initial conditions assumed to be zero.
If Laplace transform of input r(t) is represented by R(s), and that of output c(t)
is C(s).
zero are conditions initial allInput of Transform Laplace
Output of Transform Laplace G(s) function,Transfer Then =
zero are conditions initial allR(s)
C(s) G(s) =∴
Transfer function is a mathematical model and it gives the gain of the system, G(s). A
transfer function is defined only for a linear, stationary system. A non-stationary
system often called a time-varying system has one or more time-varying parameters
and the Laplace transformation may not be utilized.
Properties of Transfer Function
The properties of the transfer function are given below:
1. The ratio of the Laplace transform of output to input with all initial conditions to
be zero is known as transfer function of a system.
2. The transfer function of a system is the Laplace transform of its impulse response
under assumption of zero initial conditions.
3. Replacing ’s’ variable with linear operation dt
d D ≡ in transfer function of a
system, the differential equation of the system can be obtained.
4. The transfer function of a system does not depend on the inputs to the system.
5. The system poles and zeros can be determined from its transfer function.
6. Stability can be found from characteristic equation.
7. Transfer function cannot be defined for non-linear systems. It can be defined for
linear systems only.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
147 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
BLOCK DIAGRAM
Block diagram is a pictorial representation of the given system. Each element of
a complicated system is represented by a block. Each block is functional block. In
block diagram representation, each block represents the transfer function of an
element in the system. Unidirectional block which represents the transfer function of
the system is known as the block diagram of the system.
BASIC ELEMENTS OF BLOCK DIAGRAM
1) Block Diagram: Pictorial representation of the relationship between the input and
output of a physical system is known as block diagram.
2) Output: The value of input multiplied by the block gain is known as output.
C(s) = G(s) R(s)
3) Summing Point: At summing point, two or more signals can be added or
subtracted.
4) Branch Point (Take off Point): A branch point is a point from which the signal
from a block goes concurrently to other blocks or summing point.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
148 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
or Application of one input source to two or more systems is represented by a take
off point as shown at point A in figure.
BLOCK DIAGRAM REDUCTION
The block diagram can be reduced to find the overall transfer function of the
system. The following rules can be used for block diagram reduction.
1. Combining the Blocks in Cascade
2. Combining Parallel Blocks (or combining feed forward paths)
3. Moving the Branch Point ahead of the Block
4. Moving the Branch Point before the Block
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
149 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
5. Moving the Summing Point ahead of the Block
6. Moving the Summing Point before the Block
7. Interchanging Summing Point
8. Splitting Summing Point
9. Combining Summing Points
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
150 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
10. Elimination of feedback loop
HG1
G
R
C
RG HG)(1 C
RG CHG C
CHG-RG C
G CH)-(R C Output,
+=∴
=+
=+
=
=
REPRESENTATION OF CONTROL COMPONENTS AND SUBSYSTEMS
Or
MATHEMATICAL MODELING OF MECHANICAL SYSTEMS
To study and examine a control system it is necessary to have some type of
equivalent representation of the system. Such a representation can be obtained from
the mathematical equations, governing the behaviour of the system. Most of such
mathematical equations are different equations whether the system may be electrical,
mechanical, thermal, hydraulic etc.
The set of mathematical equations, describing the dynamic characteristic of a
system is called mathematical model of the system. Most of the control systems
contain mechanical or electrical or both types of elements and components. To analyse
such systems, it is necessary to convert such systems into mathematical models based
on transfer function approach.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
151 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
ANALYSIS OF MECHANICAL SYSTEMS
In mechanical systems, motion can be of different types, i.e. Translational,
Rotational or combination of both. The equations governing such motion in
mechanical systems are often directly or indirectly governed by Newton’s laws of
motion.
I. MECHANICAL TRANSLATIONAL SYSTEMS
Consider a mechanical system in which motion is taking place along a straight
line such systems are of translation type. These systems are characterized by
displacement, linear velocity and linear acceleration. The model of mechanical
translational systems can be obtained by using three basic elements mass, spring and
dash-pot.
a) Mass
The weight of the mechanical system is represented by the element mass and it
is assumed to be concentrated at the center of the body. If a force is applied to the
mass, displacement takes place and a reaction force is produced which acts in a
direction opposite to that of applied force. This acceleration force is proportional to
the acceleration.
2
2
M
2
2
M
M
M
M
M
dt
xd M F For
dt
xd M F
mass theis M whereMa For
a α F and
F F then
mass todue force Opposing F
and force Applied FLet
==
=
=
=
=
=
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
152 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
b) Spring
The elastic deformation of the body can be represented by a spring. When we
apply a force on the spring, the spring will offer an opposing force which is
proportional to displacement of the body.
XK F For
N/m spring; of stiffness theisK whereXK F
X α Fand
F Fthen
elasticity todue force Opposing F
andforce Applied FLet
K
K
K
K
K
==
=
=
=
=
When the spring has displacement at both ends as shown in figure, then the opposing
force is proportional to differential displacement
K 1 2
K 1 2
K 1 2
F (X - X )
F = K (X - X )
or F = F = K (X - X )
α∴
c) Dash-Pot (Damper)
The friction existing in mechanical systems can be represented by the dash-pot.
The dash-pot is a piston moving inside a cylinder filled with viscous fluid. The dash-
pot is shown in figure.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
153 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
If a force is applied to the shaft, the piston move and press the fluid, this
increase the pressure on side ‘b’ and decreasing the pressure on side ‘a’. As a result,
the fluid flow around the piston from side ‘b’ to side ‘a’.
An ideal dash-pot with one end fixed is shown in figure.
The dash-pot will offer an opposing force which is proportional to velocity of the
body.
B
B
B
B
B
Let F Applied force and
F Opposing force due to friction
then F F
dXand F α
dt
dX F B where B is the viscous friction coefficient; N-sec/m
dt
or F F
=
=
=
=
= =dX
B dt
When the dash-pot has displacement at both ends as shown in figure, then the
opposing force is proportional to differential velocity.
)X - (Xdt
d B F For
)X - (Xdt
d B For
)X - (Xdt
d α F
21B
21B
21B
==
=
∴
Procedure to determine the transfer function of Mechanical Translational System
1. Draw the free body diagrams of the system. The free body diagram is obtained by
drawing each mass separately and then marking all the forces acting on that mass.
2. For each free body diagram write one differential equation by equating the sum of
applied forces to the sum of opposing forces.
3. Take Laplace Transform of differential equations. This ratio is the transfer function
of the system.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
154 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
II. MECHANICAL ROTATIONAL SYSTEMS
The model of rotational mechanical systems can be obtained by using three
elem ents Moment of Inertia (J) of mass, Dash-pot with rotational frictional coefficient
(B) and Torsional spring with stiffness (K).
a) Moment of Inertia (J)
The weight of the rotational mechanical system is represented by the moment
of inertia of the mass. The moment of inertia of the system or body is considered to be
concentrated at the centre of gravity of the body. When a torque is applied to a
rotating body, a reactive torque is produced which acts in an opposite direction to the
applied torque. The reactive torque (opposing torque) due to moment of inertia is
proportional to the angular acceleration.
2
2
j
2
2
j
2
2
j
j
j
dt
θd J T Tor
inertia ofmoment theis J wheredt
θd J Tor
ntdisplacemeangular theis θ wheredt
θd α Tand
T Tthen
body theof inertia ofmoment todue torqueOpposing T
and torqueApplied TLet
==
=
=
=
=
b) Dash Pot with Rotational Frictional Coefficient (B)
The friction existing in rotational mechanical system can be represented by the
dash-pot. The dash-pot is a piston rotating inside a cylinder filled with viscous fluid.
When a torque is applied to the dash-pot, it will offer an opposing torque which is
proportional to the angular velocity of the body.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
155 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
dt
dθ B T Tor
tcoefficien frictional rotational theis B wheredt
dθ B Tor
ntdisplacemeangular theis θ wheredt
dθ B α Tand
T Tthen
friction todue torqueOpposing T
and torqueApplied TLet
b
b
b
b
b
==
=
=
=
=
When the dash-pot h as angular displacement at both ends as shown in figure, the
opposing torque is proportional to the differential angular velocity.
)θ - (θdt
d B T Tor
)θ - (θdt
d B Tor
)θ - (θdt
d α T
21b
21b
21b
==
=
c) Torsional Spring
The elastic deformation of the body can be represented by torsional spring.
When a torque is applied to a spring, it is twisted by an angle θ. The torsional spring
will offer an opposing force which is proportional to angular displacement of the
body.
K
K
Let T Applied torque and
T Opposing torque due to elasticity
then T T
=
=
=
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
156 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
K
K
K
and T α θ where θ is the angular displacement
or T K θ where K is the Stiffness of the spring
or T T K θ
=
= =
When the spring has angular displacement at both ends as shown in figure, the
opposing torque is proportional to the differential angular displacement.
θ2) - (θK T T
θ2) - (θK Tor
θ2) - (θ α T
1K
1K
1K
==∴
=
III. ELECTRICAL SYSTEMS
The models of electrical systems can be obtained by using resistor, capacitor
and inductor. For modeling electrical systems the electrical network or equivalent
circuit is formed by using R, L and C and voltage or current source. The differential
equations governing the electrical systems can be formed by writing Kirchoff’s current
law equations by choosing various nodes in the network or Kirchoff’s voltage law
equations by choosing various closed path in the network. The transfer function can
be obtained by taking Laplace transform of the differential equations and rearranging
them as a ratio of output to input.
Table.1: Current voltage relation of R, L and C
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
157 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Consider a series RLC circuit shown in figure.
The mathematical model of the system is
∫++= d(t) i C
1
dt
di L i R V(t)
Taking Laplace Transform
I(s) Cs
1 I(s) s L I(s) R V(s) ++=
I(s) Cs
1 s L R V(s)
++=∴
TRANSFER FUNCTION OF ARMATURE CONTROLLED DC MOTOR
The speed of DC motor is directly proportional to armature voltage and
inversely proportional to flux in field winding. The desired speed is obtained by
varying the armature voltage. Because of the field is excited by a constant voltage, we
consider only the armature circuit. The mechanical system consists of the rotating part
of the motor and load connected to the shaft of the motor. The armature controlled DC
motor speed control system is shown in figure.
Fig: Armature Controlled DC Motor
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
158 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The equivalent circuit of armature is shown as
where ia = Armature current
Va = Armature voltage
Ra = Armature resistance
La = Armature inductance
Eb = Back emf
By applying Kirchoff’s Voltage law,
(1) V e dt
di L R i ab
aaaa →=++
The torque of DC motor is proportional to the product of flux and current. Since flux
is constant in this system, the torque is proportional to armature current.
(2) i K T Torque,
i α T
at
a
→=∴
where Kt is the torque constant.
The mechanical system of the motor is shown as
The differential equation governing the mechanical system of motor is given by
(3) T dt
dθ B
dt
θd J
2
2
→=+
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
159 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The back emf of DC machine is proportional to speed (angular velocity) of shaft.
(4) dt
dθ K e emf,Back
dt
dθ α e
bb
b
→=
∴
where Kb is the Back emf constant.
The differential equations governing the armature controlled DC motor speed control
system are
(1) V e dt
di L R i ab
aaaa →=++
(2) i K T Torque, at →=
(3) T dt
dθ B
dt
θd J
2
2
→=+
(4) dt
dθ K e emf,Back bb →=
On taking Laplace transform with zero initial conditions we get,
a a a a b a R I (s) L s I (s) E (s) V (s) (5)+ + = →
t aT(s) K I (s) (6)= →
2J s θ(s) B s θ(s) T(s) (7)+ = →
b bE (s) K s θ(s) (8)= →
Equating (6) and (7) we get
( )2t a K I (s) J s Bs θ(s)= +
( )2
a
t
J s Bs I (s) θ(s) (9)
K
+∴ = →
Equation (5) can be written as
( ) (s)V (s)E (s)I sL R abaaa =++
b asubstituting E (s) and I (s) from (4) and (9)
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
160 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
( )( )
( ) ( )
2
a a b a
t
2a a t b
a
t
J s BsR L s θ(s) K s θ(s) V (s)
K
R L s J s Bs K K s θ(s) V (s)
K
++ + =
+ + =
( ) ( )
a
t
2a a a t b
θ(s) Transfer function will be
V (s)
Kθ(s)
V (s) R L s J s Bs K K s
∴
=
+ +
t2 3 2
a a a a t b
K
R J s R Bs L J s s L B K K s
=
+ + + +
[ ]
t
2a a a a t b
t
2a a t b
t
a a t b
K
s J R s R B J L s s L B K K
K
s (J s B)R (J s B s) L K K
K
s (J s B)R (J s B) s L K K
= + + + +
= + + + +
=+ + + +
[ ]t
a a t b
K
s (J s B) (R s L ) K K=
+ + +
The block diagram of the armature controlled DC motor is shown in figure,
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
161 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
TRANSFER FUNCTION OF FIELD CONTROLLED DC MOTOR
The speed of DC motor is directly proportional to armature voltage and
inversely proportional to flux in field winding. In field controlled DC motor the
armature voltage is kept constant and the speed is varied by varying the flux of the
machine. Since flux is directly proportional to field current, the flux is varied by
varying field current. For analysis only field circuit is considered because the
armature is excited by a constant voltage. The mechanical system consists of the
rotating part of the motor and the load connected to the shaft of the motor. The field
controlled DC motor speed control system is shown in figure.
Fig: Field Controlled DC Motor
The equivalent circuit of field is shown as
where if = Field current
Vf = Field voltage
Rf = Field resistance
Lf = Field inductance
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
162 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
By applying Kirchoff’s Voltage law, we can write
(1) V dt
di L i R f
ffff →=+
The torque of DC motor is proportional to the product of flux and armature current.
Since armature current is constant in this system, the torque is proportional to flux
alone, but flux is proportional to field current.
f T α i
tf f Torque, T K i (2)∴ = →
where Ktf is the torque constant.
The mechanical system of the motor is shown in figure as
The differential equation governing the mechanical system of the motor is given by
(3) T dt
dθ B
dt
θd J
2
2
→=+
The differential equations governing the field controlled DC motor are
(1) V dt
di L i R f
ffff →=+
(2) i K T Torque, ftf →=∴
(3) T dt
dθ B
dt
θd J
2
2
→=+
On taking Laplace transform with zero initial conditions we get,
f f f f f R I (s) L s I (s) V (s) (4)+ = →
tf f T(s) K I (s) (5)= →
2 J s θ(s) B s θ(s) T(s) (6)+ = →
equating (5) and (6) we get
2
tf f K I (s) J s θ(s) B s θ(s)= +
2
f
tf
(J s B s) I (s) θ(s)
K
+∴ =
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
163 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
substituting If (s) in (4)
(s)V θ(s) K
s) B s (J s) L (Rf
tf
2ff =
++
Transfer function is
s) B s (J s) L (R
K
(s)V
θ(s)
2ff
tf
f ++=
The block diagram of the field controlled DC motor is shown in figure,
TEMPERATURE CONTROL SYSTEM
Thermal systems are those that involve the transfer of heat from one substance
to another. The model of thermal systems is obtained by using thermal resistance and
capacitance which are the basic elements of the thermal system. The thermal
resistance, R for heat transfer between two substances is defined as the ratio of change
in temperature and change in heat flow rate.
rate flowheat in Change
eTemperaturin Change R ,resistance Thermal =∴
Thermal capacitance is defined as the ratio of change in heat stored and change in
temperature.
turein tempera Change
storedheat in Change C e,Capacitanc Thermal =∴
It is also defined as the product of the body’s mass, M and the specific heat of the
body, C.
CM C e,Capacitanc Thermal i.e. =
Consider a simple thermal system shown in figure. Let us assume that the tank is
insulated to eliminate heat loss to the surrounding air.
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
164 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The change in output heat flow rate,
θ ture,in tempera Change C liquid, ofheat SpecificG rate, flow Liquid q X X0 =
(1) θ CG q 0 →=
c liquid, ofheat Specific M Mass, C e,Capacitanc Thermal Χ=
(2) c M C →=∴
0q rate, flowheat in Change
θ ture,in tempera Change R ,resistance Thermal =
(3) q
θ R i.e.
0
→=
Substitute (1) in (3)
(4) CG
1
θ CG
θ R →==∴
The rate of change of temperature is directly proportional to change in heat input rate
oi q - q α dt
dθ ∴
The constant of proportionality in the capacitance C of the system
i o
dθ C q - q (5)
dt∴ = →
o
o
θ θ(3) R or q (6)
q R⇒ = = →
Module |3 I n t r o d u c t i o n t o C o n t r o l S y s t e m s E n g i n e e r i n g
165 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Substitute (6) in (5)
i
i
i
i
q R θ dt
dθ C R
θ - q R dt
dθ C R
R
θ - R q
dt
dθ C
R
θ - q
dt
dθ C
=+
=
=
=
Taking Laplace transform
i
i
R C s θ(s) θ(s) R Q (s)
θ(s) [R C s 1] R Q (s)
+ =
+ =
i
θ(s) R
Q (s) s R C 1=
+
REFERENCES
1) Control Systems - Nagoorkani A.
2) Control Systems Engineering - Ramesh Babu
3) Linear Control Systems - B.S. Mange
4) Control System Engineering - Nagrath & Gopal
5) Control Systems Theory & Applications - Smarajit Ghosh
6) Problems & Solutions in Control System Engineering - Sivanandam & Deepa
7) Modern Control Engineering - Katsuhiko Ogata
8) Control Systems - U.A. Bakshi & V.U. Bakshi
9) Control Systems Engineering - Norman S. Nise
Module |4 S y s t e m R e s p o n s e
166 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MODULE - 4
SYSTEM RESPONSE
TIME RESPONSE
The time response of the system is the output of the closed loop system as a
function of time. It is denoted by C(t).
The output in s domain, C(s) is given by the product of the transfer function and the
input R(s).
H(s) G(s)1
G(s) R(s) C(s)
+=
On taking the inverse Laplace transform of this product the time domain response,
C(t) can be obtained.
C(s) G(s)Closed loop transfer function,
R(s) 1 G(s) H(s)=
+
G(s)Response in s-domain, C(s) R(s)
1 G(s) H(s)=
+
-1 -1 G(s)Response in time domain, C(t) L [C(s)] L R(s)
1 G(s) H(s)
= = +
The time response of a control system consists of two parts.
1) The transient response
2) The steady state response
Module |4 S y s t e m R e s p o n s e
167 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The transient response shows the response of the system when the input
changes from one state to another or it is the response before the output reaching the
steady state value.
The steady state response shows the response as time, t approaches infinity.
Therefore the total time response is
TEST SIGNALS
To predict the response of the system, knowledge of input signal is required.
The commonly used test input signals are impulse, step, ramp and parabolic signals.
a) Impulse Signal
A signal which is available for very short duration is called impulse signal.
Impulse signal is a signal having zero values at all times except at t=0. At t=0, the
magnitude becomes infinite. It is denoted by δ(t).
Module |4 S y s t e m R e s p o n s e
168 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
It is expressed as
1 dt δ(t) Lt and
0 for t 0 δ(t)
1
11
t
t-0t
=
≠=
∫+
→
Laplace transform of the impulse function is unity. The response of the system, with
input impulse signal is called weighting function (impulse response) of the system.
) impulsefor 1 R(s) ( H(s) G(s)1
G(s) L
H(s) G(s)1
G(s) R(s) L C(t) i.e.
1-
1-
=
+=
+=
Q
b) Step Signal
The step signal is a signal whose value changes from zero to A at t = 0 and
remains constant at A for t > 0.
The mathematical representation of the step signal is
(t)u A r(t) =
0 for t 0; r(t)
0 for t A; r(t) or
0 t 0; u(t)
0 t 1; u(t) where
<=
≥=
<=
≥=
The Laplace transform of the step signal is
s
A L[r(t)] R(s) ==
Module |4 S y s t e m R e s p o n s e
169 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
For a unit step signal (i.e. A = 1)
s
1 R(s) =∴
c) Ramp Signal
The ramp signal is a signal whose value increases linearly with time from an
initial value of zero at t=0. The ramp signal resembles a constant velocity input to the
system.
The mathematical representation of the ramp signal is
0 for t 0; r(t)
0 for t At; r(t)
<=
≥=
Laplace transform of the ramp signal is
2
R(s) L [r(t)] L [At]
A L [t]
AR(s)
s
= =
=
=
For a unit ramp signal (i.e. A = 1)
2s
1 R(s) =∴
Module |4 S y s t e m R e s p o n s e
170 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
d) Parabolic Signal
In parabolic signal, the instantaneous value varies as square of the time from an
initial value of zero at t=0. The parabolic signal resembles a constant acceleration input
to the system.
The mathematical representation of the parabolic signal is
0 for t 0; r(t)
0 for t ;2
At r(t)
2
<=
≥=
The Laplace transform of the parabolic signal is given by
3
3
2
2
s
A
s
2
2
A
][t L 2
A
2
At L [r(t)] L R(s)
=
=
=
==
For a unit parabolic signal (i.e. A = 1)
3s
1 R(s) =∴
Module |4 S y s t e m R e s p o n s e
171 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
ORDER OF A SYSTEM
The input and output relationship of a control system can be expressed by a
differential equation. The order of the system is given by the order of the differential
equation governing the system. The order of the system is given by the maximum
power of ‘s’ in the denominator polynomial.
Q(s)
P(s)K T(s) Function,Transfer =
Order of the system is denoted by ‘n’
2
KIf n 0; T(s) ; then the system is Zero Order System
2K
If n 1; T(s) ; then the system is First Order System2s 1
K (s 2)If n 2; T(s) ; the
2s s 1
= =
= =+
+= =
+ +n the system is Second Order System
The value of n gives the number of poles in the transfer function.
RESPONSE OF FIRST ORDER SYSTEM FOR UNIT IMPULSE INPUT
Let the transfer function of a first order system is
1 Ts
K
R(s)
C(s)
+=
where K is the gain constant and T is the time constant of the system.
Time constant indicates how fast the system reaches the final value.
The input is unit impulse, then
1 R(s) and δ(t) r(t) ==
The response in s domain, 1 Ts
K R(s) C(s)
+=
K C(s)
Ts 1∴ =
+
K
1T s
T
=
+
Module |4 S y s t e m R e s p o n s e
172 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The response in time domain is given by
+
=
T
1 sT
K L C(t) 1-
at-1-t/T- e
as
1 L e
T
K =
+= Q
0 e T
K C(t) , When t
T
K 0.0067 e
T
K C(t) T, 5 When t
T
K 0.0183 e
T
K C(t) T, 4 When t
T
K 0.0498 e
T
K C(t) T, 3 When t
T
K 0.1353 e
T
K C(t) T, 2 When t
T
K 0.3679 e
T
K C(t) T, 1 When t
T
K C(t) 0, When t
-
5-
4-
3-
2-
1-
==∞=
===
===
===
===
===
==
∞
It can be plotted as
The output starts at K/T at t = 0 and decreases exponentially and reaches to zero at
t = ∞.
Module |4 S y s t e m R e s p o n s e
173 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
RESPONSE OF FIRST ORDER SYSTEM FOR UNIT STEP INPUT
Let the transfer function of a first order system is
(1) 1 Ts
1
R(s)
C(s)→
+=
If the input is unit step, then
s
1 R(s) and 1 r(t) ==
The response in s domain,
+
=
+
=
+=
+=
T
1 s s
T
1
T
1 s sT
1
1 Ts
1
s
1
1 Ts
1 R(s) C(s)
By partial fraction expansion C(s) can be expressed as
(2)
T
1 s
B
s
A
T
1 s s
T
1
C(s) →
+
+=
+
=
Multiplying (2) by s
+
+=
+
T
1 s
Bs A
T
1 s
T
1
1 A i.e.A 1
0 sPut
==∴
=
Module |4 S y s t e m R e s p o n s e
174 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Multiplying (2) by
+
T
1s
B s
T
1sA
s
T
1
+
+
=
1- B i.e.
B 0
T
1-
T
1
T
1- sPut
=
+=∴
=
+
=∴
T
1 s
1 -
s
1 C(s)
The response in time domain is given by
[ ]
+
==
T
1 s
1 -
s
1 L (s) C L C(t) 1-1-
-t/T e - 1 C(t) =∴
1 e - 1 C(t) , When t
0.993 e - 1 C(t) T, 5 When t
0.9817 e - 1 C(t) T, 4 When t
0.95 e - 1 C(t) T, 3 When t
0.865 e - 1 C(t) T, 2 When t
0.632 e - 1 C(t) T, 1 When t
0 e - 1 C(t) 0, When t
-
5-
4-
3-
2-
1-
0
==∞=
===
===
===
===
===
===
∞
Module |4 S y s t e m R e s p o n s e
175 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
It is plotted as
RESPONSE OF FIRST ORDER SYSTEM FOR UNIT RAMP INPUT
Let the transfer function of a first order system is
(1) 1 Ts
1
R(s)
C(s)→
+=
If the input is unit ramp, then
2s
1 R(s) andt r(t) ==
The response in s domain,
+
=
+
=
+=
+=
T
1 s s
T
1
T
1 s T
1
s
1
1 Ts
1
s
1
1 Ts
1 R(s) C(s)
2
2
2
Module |4 S y s t e m R e s p o n s e
176 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
By partial fraction expansion C(s) can be expressed as
(2)
T
1 s
C
s
B
s
A
T
1 s s
T
1
C(s)2
2
→
+
++=
+
=
Multiplying (2) by s2
+
++=
+
T
1 s
Cs B As
T
1 s
T
12
1 B i.e. B
T
1
T
1
0 sPut
==∴
=
Multiplying (2) by
+
T
1s
C s
T
1s B
s
T
1sA
s
T
1
22+
+
+
+
=
T C i.e. C
T
1
T
1
T
1- sPut
2
==∴
=
Substitute s = 1 in (2)
T
1 1
C B A
T
1 1
T
1
+
++=
+
Substitute the value of B & C
T
1 T
T 1 A
T
1 TT
1
+++=
+
Module |4 S y s t e m R e s p o n s e
177 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
1 T
T 1 A
1 T
1 2
+++=
+
1 T
T - 1 -
1 T
1 A
2
++=∴
( )
1 T
T - T -
1 T
T - 1 T - 1
22
+=
+
+=
( )T- A T -
1 T
T 1 T - =∴=
+
+=
T
1 s
T
s
1
s
T- C(s) So
2
+
++=
T
1 s
T
s
T -
s
1 C(s)
2
++=∴
The response in time domain is given by
[ ]
+
+==
T
1 s
T
s
T -
s
1 L (s) C L C(t)
2
1-1-
-t/T Te T - t C(t) +=∴
∞=+∞=∞=
+=+==
=+==
=+==
∞ Te T - C(t) , When t
T 0.1353 T Te T - 2T C(t) T, 2 When t
0.36797 Te T - T C(t) T, 1 When t
0 Te T - C(t) 0, When t
-
2-
1-
0
It is plotted as
Module |4 S y s t e m R e s p o n s e
178 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
SECOND ORDER SYSTEMS
The standard form of closed loop transfer function of second order system is
given by
2n
2 2n n
ωC(s) =
R(s) s + 2 ζ ω s + ω
where wn = natural frequency,
ζ = Damping ratio
The characteristic equation of the second order system is
2 2
n ns + 2 ζ ω s + ω = 0
It is a quadratic equation and the roots of this equation is given by
( )
( )
2 2 2n n n
1 2
2 2 2n n n
2 2n n
2n n
- 2 ζ ω ± 4 ζ ω - 4 ωs , s =
2
- 2 ζ ω ± 2 ζ ω - ω =
2
= - ζ ω ± ζ - 1 ω
= - ζ ω ± ω ζ - 1
The response C(t) of second order system depends on the value of damping ratio.
Depending on the value of ζ, the system can be classified into the following four cases,
When ζ = 0, Undamped System,
When 0 < ζ < 1, Under damped System,
When ζ = 1, Critically damped System,
When ζ > 1, Over damped System.
Note: Most of the physical systems are of under damped system.
Module |4 S y s t e m R e s p o n s e
179 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
RESPONSE OF UNDAMPED SECOND ORDER SYSTEM FOR UNIT STEP INPUT
The standard form of a closed loop transfer function of second order system is
given by
2n
2 2n n
ωC(s) =
R(s) s + 2 ζ ω s + ω
For Undamped system, ζ = 0
2n
2 2n
ωC(s) =
R(s) s + ω∴
When the input is unit step,
s
1 R(s) and 1 r(t) ==
Therefore The response in s-domain will be
2n
2 2n
ωC(s) = R(s)
s + ω
2n
2 2n
ω1C(s) =
s s + ω
By partial fraction expansion
( )
2n
2 22 2nn
ω A BC(s) = = +
s s + ωs s + ω
Note :- Normal case 2 2n
A Bs + C +
s s + ω
But here the roots are lie on the imaginary axis. So the value of B = 0.
( )
2n
2 22 2nn
ω A BC(s) = = + (1)
s s + ωs s + ω→
Module |4 S y s t e m R e s p o n s e
180 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Multiplying (1) by s
2n
2 2 2 2n n
ω B = A + s
s + ω s + ω
2n2n
Put s 0
ω = A A 1
ω
=
∴ =
Multiplying (1) by ( )2 2ns + ω
( )2
2 2nn
ω A = s + ω + B
s s
2 2
n nPut s - ω or s -jω= =
2n
n
ω = B
jω∴
n
n
ω B -jω -s
j∴ = = =
s- B =∴
2 2n
1 s C(s) -
s s ω∴ =
+
The time response C(t) is
[ ]-1
-1
2 2n
C(t) L C(s)
1 s L -
s s ω
=
=
+
ni.e. C(t) 1 - Cos ω t= -1
n 2 2
s L Cos ω t
s a=
+Q
Module |4 S y s t e m R e s p o n s e
181 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The response of undamped second order system for unit step input is shown in figure.
The response of undamped second order system for unit step input is completely
oscillatory. Every practical system has some amount of damping. Hence undamped
system does not exist in practice.
RESPONSE OF UNDER DAMPED SECOND ORDER SYSTEM FOR UNIT STEP INPUT
The standard form of closed loop transfer function of second order system is
given by
2n
2 2n n
ωC(s)
R(s) s + 2 ζ ω s + ω=
For Under damped system, 0 < ζ < 1 and roots of the denominator (characteristic
equation) are
( )21 2 n ns , s = - ζ ω ± ω ζ - 1
( )21 2 n n
2n n
But ζ 1
So s , s - ζ ω ± ω - 1 - ζ
- ζ ω ± jω 1 - ζ
<
=
=
The roots are complex conjugate
The response in s-domain,
2n
2 2n n
ωC(s) = R(s)
s + 2 ζ ω s + ω
Module |4 S y s t e m R e s p o n s e
182 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2n
2 2n n
ω1 C(s)
s s + 2 ζ ω s + ω∴ =
By partial fraction expansion,
( )
2n
2 22 2n nn n
ω A Bs CC(s) (1)
s s 2 ζ ω s ωs s 2 ζ ω s ω
+= = + →
+ ++ +
Multiplying (1) by s
( )
( )2n
2 22 2n nn n
Bs C sω A
s 2 ζ ω s ωs 2 ζ ω s ω
+= +
+ ++ +
Put s 0=
2n2n
ω A A 1
ω= ∴ =
on cross multiplication in (1)
( ) ( )2 2 2n n nω A s 2 ζ ω s w Bs C s= + + + +
2 2 2 2n n nω s 2 ζ ω s ω Bs Cs= + + + +
Equating coefficients of s2
1- B 0 B 1 =∴=+
Equating coefficients of s
n n2 ζ ω C 0 C -2 ζ ω+ = ∴ =
n2 2
n n
s 2 ζ ω1 C(s) -
s s 2 ζ ω s ω
+∴ =
+ +
Note:- To take the Laplace transform we want the denominator term (s + a)2 + b2
n
2 2 2 2 2 2n n n n
s 2 ζ ω1 C(s) -
s s 2 ζ ω s ω ζ ω - ζ ω
+∴ =
+ + +
( )
n2 2 2 2
n n n
s + 2 ζ ω1 -
s s + ζ ω + ω - ζ ω=
Module |4 S y s t e m R e s p o n s e
183 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
( ) ( )
n2 2 2
n n
s + 2 ζ ω1 -
s s + ζ ω + ω 1 - ζ=
Substitute ( )2d nω ω 1 - ζ=
( )
n2 2
n d
s + 2 ζ ω1 -
s s + ζ ω + ω =
We know ( )bt Cos e
b a s
a s L at-
22
1 =
++
+−
( )
n n2 2
n d
s + ζ ω + ζ ω1 -
s s + ζ ω + ω =
( ) ( )
n n2 22 2
n d n d
s ζ ω ζ ω1 -
s s ζ ω ω s ζ ω ω
+= +
+ + + +
We know ( )btSin e
b a s
b L at-
22
1 =
++
−
( ) ( )
n dn2 22 2
n d d n d
ζ ω ωs ζ ω1 -
s s ζ ω ω ω s ζ ω ω
+= +
+ + + +
On taking inverse Laplace transform
n n-ζ ω t -ζ ω tnd d
d
ζ ωC(t) 1 - e Cos ω t - e Sin ω t
ω=
n n-ζ ω t -ζ ω tn
d d2n
ζ ω 1 - e Cos ω t - e Sin ω t
ω 1 - ζ=
n-ζ ω t
d d2
ζ 1 - e Cos ω t Sin ω t
1 - ζ
= +
n-ζ ω t2
d d2
e 1 - 1 - ζ Cos ω t ζ Sin ω t
1 - ζ
= +
Module |4 S y s t e m R e s p o n s e
184 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
On constructing a right angle triangle with 2ζ - 1 and ζ , we get
The time response C(t) is
[ ]n-ζ ω t
d d2
e C(t) 1 - Sinθ Cos ω t Cosθ Sin ω t
1 - ζ= +
( )n-ζ ω t
d2
e C(t) 1 - Sin ω t θ
1 - ζ∴ = +
ζ
ζ - 1 tan θ Where
21-=
The response of under damped second order system oscillates before settling to a final
value. The oscillations depend on the value of damping ratio. The following figure
shows the response of under damped second order system for unit step input.
Fig : The response of Under damped Second order system for unit step input
Module |4 S y s t e m R e s p o n s e
185 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
RESPONSE OF CRITICALLY DAMPED SECOND ORDER SYSTEM FOR UNIT STEP INPUT
The standard form of closed loop transfer function of second order system is
given by
2n
2 2n n
ωC(s)
R(s) s + 2 ζ ω s + ω=
For Critical damping ζ = 1
2n
2 2n n
ωC(s)
R(s) s + 2 ω s + ω∴ =
( )
2n
2
n
ω
s + ω=
When input is unit step, then
s
1 R(s) and 1 r(t) ==
The response in s-domain will be,
( )
2n
2
n
ωC(s) R(s)
s + ω=
( )
2n
2
n
ωC(s)
s s ω=
+
By partial fraction expansion, we can write
( ) ( )
2n
2 2nn n
ω A B CC(s) (a)
s s + ωs s + ω s + ω= = + + →
Multiplying (a) by s
( ) ( )
2n
2 2nn n
ω B s C s A
s ωs ω s ω= + +
++ +
Module |4 S y s t e m R e s p o n s e
186 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Put s 0=
2n2n
ω A
ω
A 1
=
∴ =
Multiplying (a) by ( )2
ns ω+
( )
( )22
nnn
A s ωω B s ω C
s s
+= + + +
n
2n
n
n
Put s - ω
ω C
ω
C - ω
=
=
∴ =
Equation (a) can be written as
( ) ( )22
n n nω A s ω B s s ω Cs= + + + +
( ) ( )22
n n n
Put s 1
ω A 1 ω B 1 ω C
=
= + + + +
( ) ( )22
n n n nω 1 ω B 1 ω - ω= + + +
( ) ( )2 2n n n n nω - 1 2ω ω ω B 1 ω+ + + = +
( )n n n-1 - 2ω ω B 1 ω+ = +
( )( )
n
n
1 ω B
1 ω
− +∴ =
+
i.e. B -1=
( )
n2
n n
ω1 1 C(s) - -
s s ω s ω∴ =
+ +
Module |4 S y s t e m R e s p o n s e
187 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The response in time domain is expressed as
[ ]1C(t) L C(s)−=
( )1 n
2n n
ω1 1 L - -
s s ω s ω
−
= + +
n n-ω t -ω t
n 1 - e - ω t e =
( )n-ω t
n C(t) 1 - e 1 - ω t∴ =
The response of critically damped second order system has no oscillations. The
following figure shows the response of critically damped second order system for unit
step input.
Fig : The response of Critically damped Second order system for unit step input.
Module |4 S y s t e m R e s p o n s e
188 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
TIME DOMAIN SPECIFICATIONS
The desired performance characteristics of a system of any order may be
specified in terms of the transient response to a unit step input signal. The response of
a second order system for unit step input with various values of damping ratio is
shown in figure.
The transient response of a system to a unit step input depends on the initial
conditions. The transient response of a practical control system often exhibits damped
oscillation before reaching steady state.
Fig : Damped Oscillatory response of Second Order System
Module |4 S y s t e m R e s p o n s e
189 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The transient response characteristics of a control system to a unit step input is
specified in terms of the following time domain specifications
1. Delay time, td
2. Rise time, tr
3. Peak time, tp
4. Maximum overshoot, Mp
5. Settling time, ts
EXPRESSIONS FOR TIME DOMAIN SPECIFICATIONS
1. Delay time (td)
It is the time taken for response to reach 50% of the final value, for the very first
time.
Expression
Response of second order system for under damped case is given by
( )n-ζ ω t
d2
e C(t) 1 - Sin ω t θ (1)
1 - ζ= + →
The time required to reach 50% of output is known as delay time
d tat t 2
1 C(t) ==∴
From equation (1)
( )n d-ζ ω t
d d2
1 e 1 - Sin ω t θ
2 1 - ζ= +
( )n d-ζ ω t
d d2
1 e Sin ω t θ
2 1 - ζ= +
The result of this equation is
d
n
1 0.7 ζt
ω
+=
Module |4 S y s t e m R e s p o n s e
190 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2. Rise time (tr)
It is the time taken for response to rise from 0 to 100% of the final value, for the
very first time.
Expression
Response of second order system for under damped case is given by
( )n-ζ ω t
d2
e C(t) 1 - Sin ω t θ (1)
1 - ζ= + →
r rAt t t , C(t) C(t ) 1 ( Input is Step)= = = Q
( )n r-ζ ω t
r d r2
e C(t ) 1 - Sin ω t θ 1
1 - ζ∴ = + =
( )n r-ζ ω t
d r2
e i.e. - Sin ω t θ 0
1 - ζ+ =
n r n r-ζ ω t -ζ ω trSince -e 0, If -e 0, t It's not possible ≠ = = ∞
( )d rThe term, Sin ω t θ 0+ =
Note:- SinΦ 0 When Φ 0, π, 2π, 3π,........... = =
d r ω t θ nπ∴ + =
d rω t θ π - θ Here n 1+ = =
r
d
π - θ Rise time, t
ω∴ =
Module |4 S y s t e m R e s p o n s e
191 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2-1 2
d n
1 - ζWhere θ tan and ω ω 1 - ζ
ζ= =
2-1
r 2n
1 - ζπ - tan
ζor Rise time, t in secs
ω 1 - ζ=
3. Peak time (tp)
It is the time taken for the response to reach the peak value for the very first
time.
Expression
To find the expression for peak time, tP, differentiate C(t) with respect to ‘t’ and equate
to ‘0’.
0 C(t) dt
d i.e.,
P t t
==
For a function f(t) to be maximum when f (t) 0=
The unit step response of second order system is given by
( )n-ζ ω t
d2
e C(t) 1 - Sin ω t θ
1 - ζ= +
Module |4 S y s t e m R e s p o n s e
192 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Differentiating C(t) with respect to t
( ) ( ) ( )n n-ζ ω t -ζ ω t
n d d d2 2
d e e C(t) 0 - ζω Sin ω t θ Cos ω t θ ω
dt 1 - ζ 1 - ζ
= + + +
dC(t) 0
dt=
( ) ( ) ( )n-ζ ω t
n d d d2
- e - ζω Sin ω t θ Cos ω t θ ω 0
1 - ζ ⇒ + + + =
( ) ( )2d n n dCos ω t θ ω 1 - ζ - ζω Sin ω t θ 0+ + =
( ) ( )2d dCos ω t θ 1 - ζ - ζ Sin ω t θ 0+ + =
On constructing a right angle triangle with 2ζ - 1 and ζ ,
We get ( ) ( )d dCos ω t θ Sinθ - Cosθ Sin ω t θ 0+ + =
( )dSin ω t θ θ 0+ − =
( )dSin ω t 0=
Note:- SinΦ 0 When Φ 0, π, 2π, 3π,........... = =
d p ω t n π∴ =
p
d
π Peak time, t
ω∴ =
p 2n
πor t
ω 1 - ζ=
Module |4 S y s t e m R e s p o n s e
193 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
4. Maximum Overshoot or Peak Overshoot (Mp)
Maximum overshoot is a measure of how much the response exceeds the final
value following a step change.
Let final value = C(∞)
Maximum value = C(tP)
)C(
)C( - )C(t M Overshoot, Maximum P
P∞
∞=
% 100 X )C(
)C( - )C(t M % Overshoot, Maximum % P
P∞
∞=
where C(tP) = Peak response at t=tP
C(∞) = Final steady state value
Expression
The unit step response of second order system is given by
( )n-ζ ω t
d2
e C(t) 1 - Sin ω t θ
1 - ζ= +
, At t ∞=
( )-
d2
e C(t) C( ) 1 - Sin ω θ
1 - ζ
∞
= ∞ = × ∞ +
1 - 0=
1 =
, tAt t p=
( )n p- ζ ω t
p d p2
e C(t) C(t ) 1 - Sin ω t θ
1 - ζ= = +
d
pw
π Put t =
nd
π- ζ ω
ω
p d2d
e π C(t ) 1 - Sin ω θ
ω1 - ζ
∴ = +
Module |4 S y s t e m R e s p o n s e
194 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
( )n
d
π- ζ ω
ω
2
e 1 - Sin π θ
1 - ζ= +
( )
n2
n
π- ζ ω
ω 1 - ζ
2
e 1 - -Sinθ
1 - ζ=
2
- ζ π
1 - ζ
2
e 1 Sin θ
1 - ζ= +
On constructing a right angle triangle with 2ζ - 1 and ζ , we get
2
- ζ π
1 - ζ2
p 2
e C(t ) 1 1 - ζ
1 - ζ∴ = +
2
- ζ π
1 - ζ 1 e = +
100 X )C(
)C( - )C(t M % P
P∞
∞=∴
2
- ζ π
1 - ζ1 e - 1 X 100
1
+=
2
- ζ π
1 - ζ
P% M e X 100=
Module |4 S y s t e m R e s p o n s e
195 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
5. Settling time (ts)
It is defined as the time taken by the response to reach and stay with in a
specified tolerance band of its final value. The tolerance band is usually 2% or 5% of
the final value.
Expression
The unit step response of second order system is given by
( )n-ζ ω t
d2
e C(t) 1 - Sin ω t θ
1 - ζ= +
The response of second order system has two components. They are,
1. Decaying exponential component,
n-ζ ω t
2
e
1 - ζ
2. Sinusoidal component, ( )dSin ω t θ+
The decaying exponential term damped (or reduces) the oscillations produced
by sinusoidal component. Hence the settling time is decided by the exponential
component.
Allowable tolerance is 2% or 5%.
∴The settling time for 2% tolerance is at s tt = ,
n s-ζ ω t
2
e 0.02
1 - ζ=
Module |4 S y s t e m R e s p o n s e
196 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
For least values of ζ
n s-ζ ω t e 0.02∴ =
On taking natural logarithm we get,
( )n sζ ω t ln 0.02− =
n sζ ω t - 4− =
∴ Settling time, s
n
4t
ζ ω=
If n
1T
ζ ω= = Time constant of the system
;4T ts = error % 2for
The settling time for 5% error tolerance is at s tt = ,
n s-ζ ω t
2
e 0.05
1 - ζ=
For least values of ζ
n s-ζ ω t e 0.05∴ =
On taking natural logarithm we get,
( )n sζ ω t ln 0.05− =
n sζ ω t - 3− =
∴Settling time, s
n
3t
ζ ω=
If n
1T
ζ ω= = Time constant of the system
;3T t s = error % 5for
Module |4 S y s t e m R e s p o n s e
197 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
STEADY STATE ERROR
The Steady state error ess is the difference between the input (or desired value)
and the output of a closed loop system when t tends to infinity. As the steady state
error is an index of accuracy of a control system, therefore, the steady state error
should be minimum as far as possible.
The steady state error is the value of error signal e(t), when ‘t’ tends to infinity.
Consider a closed loop system shown in figure,
The error signal, E(s) R(s) C(s) H(s) (1)= − →
The output signal, C(s) E(s) G(s) (2)= →
Substitute (2) in (1)
[ ]H(s) G(s) E(s) R(s) E(s) (1) −=⇒
R(s) H(s) G(s) E(s) E(s) =+∴
[ ] R(s) H(s) G(s) 1 E(s) =+
Module |4 S y s t e m R e s p o n s e
198 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
∴The error signal H(s) G(s) 1
R(s) E(s)
+=
But the steady state error is defined as the value of error signal when t tends to
infinity.
∴Steady state error, sst
e lim e(t)→ ∞
=
From final value theorem, t s 0lim f (t) lim s F (s)→ ∞ →
=
(s) E s lim e 0 s
ss→
=∴
i.e., H(s) G(s) 1
R(s) s lim e
0 sss
+=
→
STEADY STATE ERROR WHEN THE INPUT IS UNIT STEP SIGNAL
The input is unit step signal, s
1 R(s) =
The steady state error, sss 0
s R(s)e lim
1 G(s) H(s)→=
+
H(s) G(s) 1
s
1 . s
lim e 0 s
ss+
=∴→
H(s) G(s) 1
1 lim
0 s +=
→
H(s) G(s) lim 1
1
0 s →+
=
P
ssK 1
1 e
+=∴
Ps 0
Where K lim G(s) H(s) →
=
The constant KP is called Positional error constant.
Module |4 S y s t e m R e s p o n s e
199 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
STEADY STATE ERROR WHEN THE INPUT IS UNIT RAMP SIGNAL
The input is unit step signal, 2s
1 R(s) =
The steady state error, H(s) G(s) 1
R(s) s lim e
0 sss
+=
→
H(s) G(s) 1
s
1 . s
lim e 2
0 sss
+=∴
→
H(s) G(s) 1
s
1
lim 0 s +
=→
H(s) G(s) s s
1 lim
0 s +=
→
s 0
1
lim s G(s) H(s)→
=
V
ssK
1 e =∴
H(s) G(s) s lim K Where0 s
V→
=
The constant KV is called Velocity error constant.
STEADY STATE ERROR WHEN THE INPUT IS UNIT PARABOLIC SIGNAL
The input is unit step signal, 3s
1 R(s) =
The steady state error, H(s) G(s) 1
R(s) s lim e
0 sss
+=
→
Module |4 S y s t e m R e s p o n s e
200 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
H(s) G(s) 1
s
1 . s
lim e 3
0 sss
+=∴
→
H(s) G(s) 1
s
1
lim 2
0 s +=
→
H(s) G(s) s s
1 lim
220 s +=
→
H(s) G(s) s lim
1
2
0 s →
=
ss
a
1 e
K∴ =
2
as 0
Where K lim s G(s) H(s)→
=
The constant Ka is called Acceleration error constant.
The error constants are tabulated as
The Positional Error Constant H(s) G(s) lim K0 s
P→
=
The Velocity Error Constant H(s) G(s) s lim K0 s
V→
=
The Acceleration Error Constant H(s) G(s) s lim K 2
0 sa
→=
Module |4 S y s t e m R e s p o n s e
201 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
STABILITY OF SYSTEMS
The closed loop transfer function can be expressed as a ratio of two
polynomials in s. The denominator polynomial of closed loop transfer function is
called characteristic equation. The roots of characteristic equation are called poles. The
roots of numerator polynomial are called zeros.
6)5s(s 4)(s
23ss M(s) e.g. For
2
2
+++
++=
3)(s 2)(s 4)(s
2)(s 1)(s M(s)
+++
++=
The poles are s = -4, s= -2, s= -3
The zeros are s= -1, s= -2
The poles and zeros are plotted on the s-plane. The poles are represented by the
symbol 'X' and the zeros are represented as 'o'. The x axis of 's' plane is "Real axis"
plots the real part of the complex variable. The y axis is "Imaginary axis" and plots the
imaginary part of the complex number.
The complex variable jw σ s ±= is represented in this’s’ plane. The’s’ plane have two
half’s "Left Half" and "Right Half".
When the poles of the transfer function lie in the left half of s-plane, then the system is
said to be stable. or If all the roots of characteristic equation have negative real parts
then the system is said to be a stable system.
Module |4 S y s t e m R e s p o n s e
202 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
ROUTH HURWITZ CRITERION
The closed loop transfer function of a system is a ratio of two polynomials in s.
The denominator polynomial of closed loop transfer function is called the
characteristic equation of the system. The roots of the characteristic equation of a
stable system should lie on the left of s plane. Hence the roots should have negative
real parts.
The Routh-Hurwitz stability criterion is an analytical procedure for
determining whether all the roots of a polynomial have negative real parts or not.
ANALYSIS OF STABILITY
Step 1:- Examine the characteristic equation. The necessary condition for stability is
that all the coefficients of the polynomial be positive. If some of the
coefficients are zero or negative it can be concluded that the system is
unstable.
Step 2:- Construct a Routh array. Let the characteristic polynomial be
0
n1
1-n3-n
32-n
21-n
1n
0 sa sa ............. sa sa sa sa ++++++
The coefficients of the polynomial are arranged in two rows as shown below
................... a a a a : s
................... a a a a : s
7531n
6420n
Step 3:- Construction of third row in Routh array. Third row is constructed from the
first two rows.
1
5041
1
30212-n
a
a a - a a
a
a a - a a : s
××××
Note:- By the construction of Routh array the missing terms are considered as zeros.
Step 4:- Form rows up to s0
CHECKING STABILITY
i. The necessary condition for stability is that all of the elements in the first column
of the Routh array be positive.
ii. The number of sign changes in the elements of the first column of the Routh
array corresponds to the number of roots of the characteristic equation in the
right half of the s-plane.
Module |4 S y s t e m R e s p o n s e
203 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Note:- If the order of first column element is +, +, -, +. Then + to – is considered as one
sign change and – to + is another sign change.
If there is no sign change in the first column of Routh array then all the roots are lying
on left half of s-palne and the system is stable.
ADVANTAGES AND LIMITATIONS OF ROUTH’S CRITERION
Advantages
Advantages of Routh’s Array methods are:
i) Stability of the system can be judged without actually solving the characteristic
equation.
ii) No evaluation of determinants, which saves calculation time.
iii) For unstable system it gives number of roots of characteristic equation having
positive real part.
iv) Relative stability of the system can be easily judged.
v) By using this criterion, critical value of system gain can be determined hence
frequency of sustained oscillations can be determined.
vi) It helps in finding out range of values of K for stability.
vii) It helps in finding out intersection points of root locus with imaginary axis.
Limitations
Limitations of Routh’s Array methods are:
i) It is valid only for real coefficients of the characteristic equation.
ii) It does not provide exact locations of the closed loop poles in left or right half of
s – plane.
iii) It does not suggest methods of stabilizing an unstable system.
iv) Applicable only to linear systems.
Module |4 S y s t e m R e s p o n s e
204 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
SPECIAL CASES
Case I : A Row of all zeros
A row with all zeros indicates the possibility of roots on imaginary axis.
Solution Method
1. Determine the auxiliary polynomial A(s).
2. Differentiate the auxiliary polynomial with respect to s, to get ds
A(s) d.
3. The row of zeros is replaced with coefficients of ds
A(s) d.
4. Continue the construction of the array in the usual manner.
If there are sign changes in the first column of routh array then the system is
unstable.
The number of roots on imaginary axis can be estimated from the roots of auxiliary
polynomial.
If there is no sign changes in the first column of routh array then the all zeros row
indicate the existence of purely imaginary roots and so the system is immediately
or marginally stable.
Case II : First element of a Row is zero
If a zero is encountered as first element of a row in the Routh array then all the
elements of the next row will be infinite. To over come this problem substitute ∈ for 0
and complete the construction of array in the usual way. Finally let 0 →∈ and
determine the values of the elements of the array which are functions of .∈
Checking for Stability
If there is no sign change in first column of Routh array, then the system is
stable.
If sign change occurs, then the system is unstable.
If there is a row of all zeros after letting 0∈ → , then there is a possibility of roots
on imaginary axis (then do like case I).
Module |4 S y s t e m R e s p o n s e
205 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
REFERENCES
1) Control Systems - Nagoorkani A.
2) Control Systems Engineering - Ramesh Babu
3) Linear Control Systems - B.S. Mange
4) Control System Engineering - Nagrath & Gopal
5) Control Systems Theory & Applications - Smarajit Ghosh
6) Problems & Solutions in Control System Engineering - Sivanandam & Deepa
7) Modern Control Engineering - Katsuhiko Ogata
8) Control Systems - U.A. Bakshi & V.U. Bakshi
9) Control Systems Engineering - Norman S. Nise
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
206 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
MODULE - 5
FREQUENCY RESPONSE ANALYSIS
The frequency response is the steady state response (output) of a system when
the input to the system is a sinusoidal signal.
Consider a linear time invariant (LTI) system, H. Let x(t) be an input sinusoidal
signal. The response or output y(t) is also a sinusoidal signal of same frequency but
with different magnitude and phase angle.
The magnitude and phase relationship between the sinusoidal input and the
steady state output of a system is termed the frequency response.
The frequency response of a system is normally obtained by varying the
frequency of the input signal by keeping the magnitude of the input signal at a
constant value.
In the system transfer function T(s), if s is replaced by jω then the resulting
transfer function T(jω)
is called sinusoidal transfer function. The frequency response
of the system can be directly obtained from the sinusoidal transfer function T(jω) of
the system.
The frequency response can be evaluated for both open loop system and closed
loop system.
Open Loop Transfer Function, G(jω) G(jω) G(jω)= ∠
Loop Transfer Function is, G(jω) H(jω) G(jω) H(jω) G(jω) H(jω)= ∠
C(jω)Closed Loop Transfer Function is, M(jω) M(jω) M(jω)
R(jω)= = ∠
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
207 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
FREQUENCY DOMAIN SPECIFICATIONS
The performance and characteristics of a system in frequency domain are
measured in terms of frequency domain specifications. The requirements of a system
to be designed are usually specified in terms of these specifications.
The frequency domain specifications are
1. Resonant Peak, Mr
2. Resonant Frequency, rω
3. Bandwidth
4. Cut-off rate
5. Gain Margin
6. Phase Margin
GAIN MARGIN, Kg
The gain margin, Kg is defined as the reciprocal of the magnitude of Open Loop
Transfer Function at Phase Cross Over Frequency.
The frequency at which the phase of Open Loop Transfer Function is 1800 is
called the phase cross-over frequency, pcω .
g
pc
1Gain Margin, K
G(jω )=
The gain margin in db can be expressed as,
g g
pc
1K in db 20 log K 20 log
G(jω )= =
pc-20 log G(jω )=
pc pc:- G(jω ) G(jω) at ω ωNote is the magnitude of =
The Gain Margin indicates the amount by which the gain of the system can be
increased without affecting the stability of the system.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
208 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PHASE MARGIN ( γ )
The Phase Margin γ is that amount of additional phase lag at the Gain Cross
over frequency required to bring the system to the verge of instability. The Gain Cross
over frequency gcω is the frequency at which the magnitude of the Open Loop
transfer function is unity.
The Phase Margin γ is obtained by adding 1800 to the phase angle Φ of the
open loop transfer function at the Gain Cross over frequency
0gcPhase Margin, γ 180 Φ= +
gc gcwhere Φ G(jω )= ∠
gc gcand G(jω ) is the Phase angle of G(jω) at ω ω∠ =
FREQUENCY RESPONSE PLOTS
Frequency Response analysis of control systems can be carried either
analytically or graphically. The various graphical techniques available for frequency
response analysis are
1. Bode Plot
2. Polar Plot (or Nyquist Plot)
3. Nichols Plot
4. M and N Circles
5. Nichols Chart
The frequency response plots are used to determine the frequency domain
specifications, to study the stability of the systems and to adjust the gain of the system
to satisfy the desired specifications.
Bode plot, Polar plot and Nichols plot are usually drawn for Open loop
systems. From the Open loop response plot the performance and stability of closed
loop systems are estimated.
M and N circles and Nichols chart are used to graphically determine the
frequency response of unity feedback closed loop system from the knowledge of open
loop response.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
209 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
BODE PLOTS
Bode plot is drawn for open loop systems. Sometimes it can be drawn for
closed loop systems also. Bode plot consists of two graphs. One is a plot of the
magnitude of a sinusoidal transfer function versus log ω. The other is a plot of the
phase angle of a sinusoidal transfer function versus log ω. The standard
representation of the logarithmic magnitude of open loop transfer function of
G(jω) is 20 log G(jω) . The unit used in this representation of the magnitude is the
decibel (db). The curves are drawn on semilog paper, using the log scale for frequency
and the linear scale for either magnitude (in decibels) or phase angle (in degrees).
Advantages of Bode Plot
• The main advantage of the bode plot is that multiplication of magnitudes can
be converted in to addition.
• A simple method for sketching an approximate log-magnitude curve is
available.
Consider the Open loop transfer function,
1
2 3
1
2 3
2 2 -11 1
2 2 -1 2 2 -12 2 3 3
K(1 sT ) G(s)
s(1 sT ) (1 sT )
put s jω
K(1 jωT ) G(jω)
jω(1 jωT ) (1 jωT )
K 0 1 ω T tan ωT
ω 90 1 ω T tan ωT 1 ω T tan ωT
+=
+ +
=
+∴ =
+ +
∠ + ∠=
∠ + ∠ + ∠
q The Magnitude of G(jω)
2 21
2 2 2 22 3
K 1 ω T G(jω)
ω 1 ω T 1 ω T
+=
+ +
q The Phase angle of G(jω)
-1 -1 -11 2 3 G(jω) tan ωT - 90 - tan ωT - tan ωT∠ =
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
210 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The magnitude can be expressed in decibels as
2 21
2 2 2 22 3
2 21 2 2 2 2
2 3
G(jω) in db 20 log G(jω)
K 1 ω T 20 log
ω 1 ω T 1 ω T
K 1 1 20 log X 1 ω T X X
ω 1 ω T 1 ω T
K 20 log 20 lo
ω
=
+ = + +
= + + +
= + 2 21 2 2 2 2
2 3
2 2 2 2 2 21 2 3
1 1 g 1 ω T 20 log 20 log
1 ω T 1 ω T
K 20 log 20 log 1 ω T 20 log 1 ω T 20 log 1 ω T
ω
+ + ++ +
= + + − + − +
So it is clear that, when the magnitude is expressed in db, the multiplication is
converted to addition. To sketch the magnitude plot, knowledge of the magnitude
variations of individual factor is essential.
BASIC FACTORS OF G(jω)
The basic factors that very frequently occur in a typical transfer function G(jω)
are,
1. Constant Gain, K
Let G(s) = K
∴ G(jω) = K and K < 0
Magnitude, A G(jω) in db 20 log K
Phase, G(jω) 0
= =
Φ = ∠ =
Therefore the Magnitude Plot for a Constant Gain K is a horizontal straight line at the
magnitude of 20 log K db.
The Phase Plot is straight line at 00.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
211 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
2. Integral Factor, K
jω
0
0
K Let G(s)
s
K K G(jω) -90
jω jω
KMagnitude, A G(jω) in db 20 log
ω
Phase, Φ G(jω) -90
1When ω 0.1K, A 20 log 20 db
0.1
When ω K, A 20 log 1
=
∴ = = ∠
= =
= ∠ =
= ∴ = =
= ∴ = 0 db
1When ω 10K, A 20 log 20 db
10
=
= ∴ = = −
§ From the above analysis it is evident that the magnitude plot of the factor is a
straight line with a slope of –20 db/dec and passing through zero db, when
ω = K.
§ Since the ∠ G(jω) is a constant and independent of ω the phase plot is a straight
line at –900.
2.b Integral Factor has multiplicity of n, ( )
n
K
jω
n
0
n n
K Let G(s)
s
K K G(jω) -90n
(jω) ω
=
∴ = = ∠
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
212 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
n
n1 1
n n
0
KMagnitude, A G(jω) in db 20 log
ω
K K 20 log 20 n log
ω ω
Phase, Φ G(jω) -90 n
= =
= =
= ∠ =
Now the magnitude plot of the integral factor is a straight line with a slope of
–20 n db/dec and passing through zero db when ω = K1/n. For example let G = K/s2,
then the slope is –40 db/dec. The phase plot is a straight line at –90 n0.
3. Derivative Factor, K(jω)
( ) ( )
( )
0
0
Let G(s) Ks
G(jω) K jω Kω 90
Magnitude, A G(jω) in db 20 log Kω
Phase, Φ G(jω) 90
0.1When ω , A 20log 0.1 20 db
K
1When ω , A 20log 1
K
=
∴ = = ∠
= =
= ∠ = +
= ∴ = = −
= ∴ = 0 db
10When ω , A 20log 10 20 db
K
=
= ∴ = = +
§ From the above analysis it is evident that the magnitude plot of the derivative
factor is a straight line with a slope of +20 db/dec and passing through zero db,
when ω = 1/K.
§ Since the ∠ G(jω) is a constant and independent of ω, the phase plot is a
straight line at +900.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
213 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
3.b Derivative Factor with a multiplicity of n, n[ K(jω) ]
( )
n
n n 0
n
1
n
0
Let G(s) Ks
G(jω) K(jω) Kω 90 n
Magnitude, A G(jω) in db 20 log Kω
20 n log (K ω)
Phase, Φ G(jω) 90 n
=
∴ = = ∠
= =
=
= ∠ =
Now the magnitude plot of the integral factor is a straight line with a slope of
+20 n db/dec and passing through zero db when ω = 1/K1/n. For example let G = Ks2,
then the slope is +40 db/dec. The phase plot is a straight line at +90 n0.
4. First Order Factor in denominator 1
1 jωT+
-1
2 2
2 2
2 2
1 Let G(s)
1 sT
1 1 G (jω) -tan ωT
1 jωT 1 ω T
1M agnitude, A G(jω) in db 20 log
1 ω T
1 -20 log
1 ω T
=+
∴ = = ∠+ +
= = +
=+
2 2
At very low frequencies ωT 1
A -20 log 1 ω T
-20 log 1 0
∴ = +
≈ =
=
2 2
2 2
At very high frequencies ωT 1
A -20 log 1 ω T
-20 log ω T -20 log ωT
∴ = +
≈ =
?
1at ω , A -20 log 1 0
T
10at ω , A -20 log 10 -20 db
T
= = =
= = =
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
214 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The above analysis shows that the magnitude plot of the factor can be
approximated by two straight lines, one is a straight line at 0db for the frequency
range 0 < ω < and the other is a straight line with slope –20 db/dec for the frequency
range ( < ω < ∞). The two straight lines are asymptotes of the exact curve. The
frequency at which the two asymptotes meet is called the corner frequency or break
frequency. For the factor the frequency ω = is the corner frequency, ωc. It
divides the frequency response curve into two regions, a curve for low frequency
region and a curve for high frequency region.
The Phase Plot is obtained by calculating the phase angle of G(jω) for various values
of ω. -1
c
-1 -1 0
-1
-1
Phase angle, Φ G(jω) -tan ωT
1At the corner frequency, ω ω
T
1& Phase angle, Φ -tan X T -tan 1 -45
T
As ω 0 -tan 0 0
As ω -tan -90
∴ = ∠ =
= =
= = =
→ Φ = =
→ ∞ Φ = ∞ = 0
The Phase angle of the factor varies from 00 to –900 as ω is varied from zero
to infinity. The Phase Plot is a curve passing through –450 at ωc.
Bode Plot of the factor 1
1 jωT+
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
215 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
4.b. First Order Factor in the denominator has a multiplicity of m; ( )
m
1
1 jωT+
( )
( )
( )
m
m
m2 2 -1
1 Let G(s)
1 sT
1 & G(jω )
1 jωT
1
1 ω T m tan ωT
=+
= +
=
+ ∠
( )m
2 2
2 2
M agnitude, A G (jω) in db
1 20 log
1 ω T
-20 m log 1 ω T
=
=
+
= +
-1
Phase, Φ G(jω)
-m tan ωT
= ∠
=
Now the magnitude plot can be approximated by two straight lines, one is a straight
line at zero db for the frequency range 0 ∠ w ∠
and the other is a straight line with
slope –20 m db/dec for the frequency range
∠ w ∠ ∞.
The corner frequency ωc =
. The phase angle of the factor
( ω ) varies
from 00 to –90 m0 as ω is varied from zero to infinity. The phase plot is a curve passing
through –45 m0 at ωc.
5. First Order Factor in the numerator, (1 + jωT)
2 2 -1
Let G(s) 1 sT
& G(jω) 1 jωT
G(jω) 1 ω T tan ωT
= +
= +
∴ = + ∠
2 2
M agnitude, A G(jω) in db
20 log 1 ω T
=
= +
-1
Phase, Φ G(jω)
tan ωT
= ∠
=
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
216 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
By an analysis similar to that of previous section it can be shown that the magnitude
plot of the factor (1+jωT) can be approximated by two straight lines, one is a straight
line at zero db for the frequency range 0 ∠ ω ∠ and the other is a straight line with
slope +20 db/dec for the frequency range ∠ ω ∠ ∞.
The corner frequency ωc = . The phase angle of the factor (1+jωT) varies from
00 to +900 as ω is varied from zero to infinity. The phase plot is a curve passing
through +450 at ωc.
Bode Plot of the factor ( )1 jωT+
5. b. First Order Factor in the numerator has a multiplicity of m, (1 + jωT)m
( )
( )
( )
( )
m
m
m2 2 -1
m2 2
2 2
Let G(s) 1 sT
& G(jω) 1 jωT
G(jω) 1 ω T m tan ωT
Magnitude, A G(jω) in db
20 log 1 ω T
20 m log 1 ω T
Ph
= +
= +
∴ = + ∠
=
= +
= +
-1
ase, Φ G(jω)
m tan ωT
= ∠
=
Now the magnitude plot of the factor (1+jωT)m can be approximated by two straight
lines, one is a straight line at zero db for the frequency range 0 ∠ ω ∠ and the other
is a straight line with a slope of +20 m db/dec for the frequency range ∠ ω ∠ ∞.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
217 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The corner frequency ωc =
. The phase angle of the factor (1+jωT)m varies from
00 to +90 m0 as ω is varied from zero to infinity. The phase plot is a curve passing
through +45 m0 at ωc.
6. Quadratic Factor in the denominator, 2
n n
1
jω jω1 2
ω ως
+ +
2
n n
2
n n
2
n n
22 22
2 2n n
1 Let G(s)
s s1 2
ω ω
1 G(jω)
jω jω1 2
ω ω
1
ω ω1 j2
ω ω
1
ω ω1 4
ω ω
ς
ς
ς
ς
=
+ +
=
+ +
=
− +
= ∠
− +
-1 n2
2n
ω2
ω -tan
ω1
ω
ς
−
22 2
2
2 2n n
22 2
2
2 2n n
4 2
4 2n n
Magnitude, A G(jω) in db
1 20 log
ω ω1 4
ω ω
ω ω -20 log 1 4
ω ω
ω ω -20 log 1 -2 4
ω ω
ς
ς
=
=
− +
= − +
= + +
( )
22
2n
2 42
2 4n n
ω
ω
ω ω -20 log 1 2 - 4
ω ω
ς
ς
= − +
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
218 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
( )
n
2 42
2 4n n
At very low frequencies when ω ω ,
ω ωThe terms 2 - 4 & approches to zero
ω ω
The magnitude is, A -20 log 1 0
ς
∴ = =
=
( ) ( )
n
2 22 2
2 2n n
At very high frequencies when ω ω ,
ω ωThen 1 - 2 - 4 2 - 4
ω ως ς≈
?
( )4 2
2
4 2n n
ω ωwhen compared to , 2 - 4 is negligible
ω ως
4
4n
2
2n
2
n
n
ω The magnitude is, A -20 log
ω
ω -20 log
ω
ω -20 log
ω
ω -20 X 2 log
ω
∴ =
=
=
=
n
ω A -40 log
ω
∴ =
n
n
At ω = ω , A = -40 log 1 = 0 db
At ω = 10 ω , A = -40 log 10 = -40 db
From the above analysis it is evident that the magnitude plot of the quadratic factor in
the denominator can be approximated by two straight lines, one is a straight line at
zero db for the frequency range 0 ∠ ω ∠ ωn and the other is a straight line with a slope
of -40 db/dec for the frequency range ωn ∠ ω ∠ ∞. The two straight lines are
asymptotes of the exact curve. The frequency at which the two asymptotes meet is
called the corner frequency. For the quadratic factor, the frequency ωn is the corner
frequency, ωc.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
219 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The Phase Plot is obtained by calculating the phase angle of G(jω) for various values
of ω.
-1 n2
2n
ω2
ω Φ G(jω) -tan
ω1
ω
ς ∴ = ∠ =
−
-1 -1 0n
-1 0
-1 0
2At ω ω Φ -tan -tan -90
0
At ω 0 Φ -tan 0 0
At ω Φ -tan -180
ς = = = ∞ =
→ = =
∞ → ∞ = = ∞
[Here the angle contribution obtained must be considered by subtracting 180 from the
positive φ. This happens because behavior of tan-1 function for the complex quantities
with real part negative or imaginary part negative, cannot be identified on calculator
by using above formula.]
7. Quadratic Factor in the Numerator,
2
n n
jω jω 1 2
ω ως
+ +
2
n n
2
n n
s s Let G(s) 1 2
ω ω
jω jω G(jw) 1 2
ω ω
ς
ς
= + +
= + +
-1 n22
2 22 2
2 2 nn n
ω2
ω1 tan
ωω ω 1
1 4 ωω ω
ς
ς
= ∠ −
− +
The magnitude plot of the quadratic factor in the numerator can be
approximated by two straight lines, one is a straight line at zero db for the frequency
range 0 ∠ ω ∠ ωn and the other is a straight line with a slope of +40 db/dec for the
frequency range ωn ∠ ω ∠ ∞. The two straight lines are asymptotes of the exact curve.
The frequency at which the two asymptotes meet is called the corner frequency.
The corner frequency is ωc. The phase angle varies from 00 to +1800, as ω is
varied from zero to infinity. At the corner frequency the phase angle is +900.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
220 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The basic factors of G(jw) in the magnitude and phase plot are tabulated as
No. Basic Factors of G(jw) Magnitude Plot Phase Plot
1. K Amplitude, A = 20 log K
No Slope Angle 00
2. K
jω
A = 20 log
Slope is –20 db
Angle -900
3. ( )
n 2
K K eg.,
sjω
A = 20 log
Slope is –20 n db
eg., -40 db
Angle –90 n0
eg., -1800
4. K(jω) A = 20 log (Kω)
Slope is +20 n db Angle +900
5. n 2K(jω) eg., Ks
A = 20 log (Kωn)
Slope is +20 n db
eg., +40 db
Angle +90 n0
eg., +1800
6. 1
1 jωT+ Slope is –20 db Angle –tan-1 ωT
7. ( ) ( )
m 2
1 1 eg.,
1 jωT 1 0.2s+ + Slope is –20 n db
e.g., -40 db
Angle –m tan-1 ωT
e.g., –2 tan-1 0.2ω
8. ( )1 jωT+ Slope is +20 db Angle tan-1 ωT
9. ( ) ( )m 2
1 jωT eg., 1 0.2s+ + Slope is +20 m db
e.g., +40 db
Angle m tan-1 ωT
e.g., 2 tan-1 0.2ω
10. 2
n n
1
jω jω1 2
ω ως
+ +
Slope is –40 db
-1 n2
2n
ω2
ωAngle -tan
ω1-
ω
ς
11.
2
n n
jω jω1 2
ω ως
+ +
Slope is +40 db
-1 n2
2n
ω2
ωAngle tan
ω1-
ω
ς
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
221 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PROCEDURE FOR MAGNITUDE PLOT OF BODE PLOT
Step. 1:- Convert the transfer function into Bode form or time constant form.
The Bode form of the transfer function is
( )
1
2
2 2n n
K(1 sT )G(s)
s ss 1 sT 1 2
ω ως
+=
+ + +
( )
1
2
2 2n n
K(1 jωT ) G(s)
ω ωjω 1 jωT 1 j2
ω ως
+∴ =
+ − +
Step. 2:- Find the corner frequencies of each factor in transfer function and list them in
increasing order of Corner frequency. If the sinusoidal transfer function has a
term like K,
( ) or K(jω) then enter that factor as first term in the table.
Find the slop contributed by each factor and net slope from the corner
frequency.
Prepare a table as shown below.
Term Corner Frequency
rad/sec
Slope
db/dec
Change in Slope
db/dec
Step. 3:- Choose an arbitrary frequency ωl which is lesser than the lowest corner
frequency. Calculate the db magnitude of K,
( ) or K(jω) at ωl and at
the lowest corner frequency.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
222 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Step. 4:- Then calculate the gain (db magnitude) at every corner frequency one by one
by using the formula,
Gain at ωy = Change in gain from ωx to ωy + Gain at ωx
=
Slope from ωx to ωy X log
y
x
ω
ω
+ Gain at ωx
Step. 5:- Choose an arbitrary frequency ωh which is greater than the highest corner
frequency. Calculate the gain at ωh by using the formula in Step 4.
Step. 6:- In a Semi log graph sheet mark the required range of frequency on X – axis
(log scale) and the range of db magnitude on Y – axis (Ordinary scale) after
choosing proper scale.
Step. 7:- Mark all the points obtained in steps 3, 4 and 5 on the graph and join the
points by straight lines. Mark the slope at every part of the graph.
PROCEDURE FOR PHASE PLOT OF BODE PLOT
The Phase Plot is an exact plot and no approximations are made while drawing
the phase plot. Hence the exact phase angles of G(jω) are computed for various values
of ω and tabulated. The choices of frequencies are preferably the frequencies chosen
for magnitude plot. Usually the magnitude plot and phase plot are drawn in a single
semi log sheet on a common frequency scale. Take another Y-axis in the graph where
the magnitude plot is drawn and in this Y- axis mark the desired range of phase
angles after choosing proper scale. From the tabulated values of w and phase angles,
mark all the points on the graph. Join the points by a smooth curve.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
223 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Determination of Gain Margin and Phase Margin from Bode Plot
The Gain Margin in db is given by the negative of db magnitude of G(jω) at the
Phase Cross-over frequency, ωpc. The ωpc is the frequency at which phase of G(jω) is
–1800. If the db magnitude of G(jω) at ωpc is negative then gain margin is positive and
vice versa.
Let φgc be the phase angle of G(jω) at gain cross over frequency ωgc. The ωgc is
the frequency at which the db magnitude of G(jω) is zero. Now the phase margin, γ is
given by,
γ = 180 + φgc
If φgc is less negative than –1800 then phase margin is positive and vice versa. The
positive and negative gain margins are illustrated in figure.
Fig:- Bode Plot showing Phase Margin (γ) and Gain Margin (Kg)
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
224 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
POLAR PLOT
The Polar Plot of a sinusoidal transfer function G(jω) is a plot of the magnitude
of G(jω) versus the phase angle of G(jω) on polar coordinates as w is varied from zero
to infinity. Thus the Polar Plot is the locus of vectors G(jω) ∠ G(jω) as ω is varied
from zero to infinity. The polar plot is also called Nyquist Plot.
The Polar plot is usually plotted on a polar graph sheet. The polar graph sheet
has concentric circles and radial lines. The circles represent the magnitude and the
radial lines represent the phase angles. Each point on the polar graph has a magnitude
and phase angle. The magnitude of a point is given by the value of the circle passing
through that point and the phase angle is given by the radial line passing through that
point. In polar graph sheet a positive phase angle is measured in anticlockwise from
the reference axis (00) and a negative angle is measured clockwise from the reference
axis (00).
If G(jω) can be expressed in rectangular coordinates as
G (jω) = GR (jω) + GI (jω)
where GR (jω) = Real part of G (jω)
and GI (jω) = Imaginary part of G (jω)
Then the polar plot can be plotted in ordinary graph sheet between GR (jω) and
GI (jω) as ‘ω’ is varied from 0 to ∞.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
225 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
To plot the polar plot, first compute the magnitude and phase of G (jω) for
various values of w and tabulate them. Usually the choices of frequencies are corner
frequencies and frequencies around corner frequencies. Choose proper scale for the
magnitude circles. Fix all the points on polar graph sheet and join the points by
smooth curve. Write the frequency corresponding to each point on the plot.
To plot the polar plot on ordinary graph sheet, compute the magnitude and
phase for various values of w. Then convert the polar coordinates to rectangular
coordinates using conversion (Polar to rectangular conversion) in the
calculator. Sketch the polar plot using rectangular coordinates.
For minimum phase transfer function with only poles, the type number of the
system determines at what quadrant the polar plot starts and the order of the system
determines at what quadrant the polar plot ends.
Note:- Type determines the power of ‘s’ term and order is the maximum power of ‘s’
terms of the characteristic equation.
TYPICAL SKETCHES OF POLAR PLOT
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
226 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
227 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
DETERMINATION OF GAIN MARGIN & PHASE MARGIN FROM POLAR PLOT
The gain margin is defined as the inverse of the magnitude of G(jω) at phase
crossover frequency. The phase crossover frequency is the frequency at which the
phase of G(jω) is 1800.
Let the polar plot cut the 1800 axis at point B and the magnitude circle passing
through the point B is . Now the Gain Margin, . If the point B lies within
unity circle then the Gain Margin is positive otherwise negative.
The phase margin is defined as, phase margin, where is
the phase angle of G(jω) at gain crossover frequency. The gain crossover frequency is
the frequency at which the magnitude of G(jω) is unity.
Let the polar plot cut the unity circle at point A as shown in figure. Now the
phase margin, γ is given by AOP,∠ i.e., if AOP∠ is below -1800 axis then the phase
margin is positive and if it is above -1800 axis then the phase margin is negative.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
228 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
NYQUIST STABILITY CRITERION
Consider the closed loop transfer function
C(s) G(s) (1)
R(s) 1 G(s) H(s)= →
+
The characteristic equation of the system is given by the condition
1 G(s) H(s) 0+ =
Let F(s) 1 G(s) H(s) (2)= + →
1 2 m
1 2 n
(s - Z ) (s - Z ) ......... (s - Z )or F(s) (3)
(s - P ) (s - P ) ......... (s - P )= →
The roots of numerator polynomial are zeros and the roots of denominator
polynomial are poles. Let s be a complex variable represented by s σ jω = + on the
complex s-plane.
The function F(s) is also complex and may be defined as F(s) u jv = + and
represented on the complex F(s)-plane with coordinates u and v. The equation (3)
indicates that for every point s in the s-plane at which F(s) is analytic, there exists a
corresponding point F(s) in the F(s) plane.
Hence it can be concluded that the function F(s) maps the points in the s-plane
into the F(s)-plane.
Fig: An arbitrary contour in s-plane and its corresponding contour in F(s) plane
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
229 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
PROCEDURE FOR INVESTIGATING THE STABILITY USING NYQUIST CRITERION
The following steps can be followed to investigate the stability of closed loop
system from the knowledge of open loop system, using Nyquist Stability Criterion.
Step.1:- Choose a Nyquist contour as shown in fig (a), which encloses the entire right
half s-plane except the singular points. The Nyquist contour encloses all the
right half s-plane poles and zeros of G(s) H(s) [The poles on imaginary axis
are singular points and so they are avoided by taking a detour around it as
shown in fig (b) and (c)].
Step.2:- The Nyquist contour should be mapped in the G(s) H(s) plane using the
function G(s) H(s) to determine the encirclement -1 + j0 point in the G(s) H(s)
plane. The Nyquist contour of fig. b can be divided into four sections C1, C2,
C3 and C4. The mapping of the four sections in the G(s) H(s) plane can be
carried section wise and then combined together to get entire G(s) H(s)
contour.
Step.3:- In section C1 the value of ω varies from 0 to +∞. The mapping of section C1 is
obtained by letting s = jω in G(s) H(s) and varying ω from 0 to +∞,
s jω ω = 0 to ω 0 to i.e., G(s) H(s) G(jω) H(jω)= ∞= ∞
=
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
230 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The locus of G(jω) H(jω) as ω is varied from 0 to +∞ will be the G(s) H(s)
contour in G(s) H(s) plane corresponding to section C1 in s-plane. This locus
is the polar plot of G(jω) H(jω). To map this section of G(s) H(s) contour
separate the real and imaginary part of G(jω) H(jω). Equate the imaginary
part to zero, to find the frequency at which the G(jω) H(jω) locus crosses real
axis (to find phase crossover frequency). Substitute this frequency on real part
and find the crossing point of the locus on real axis. Sketch the approximate
locus of G(jω) H(jω) from the knowledge of type number and order of the
system or from the value of G(jω) H(jω) at ω = 0 and ω = ∞.
Step.4:- In section C2 of Nyquist contour has a semicircle of infinite radius. Therefore,
every point on section C2 has infinite magnitude but the argument varies from
π π to .
2 2+ − Hence the mapping of section C2 from s-plane to G(s) H(s) plane
can be obtained by letting jθ
Rs Lt Re
→∞= in G(s) H(s) and varying θ from
π π to .
2 2+ −
On letting, jθ
Rs Lt Re
→∞= we get
( )jθ
R
1n-ms Lt Re jθ
R
K G(s) H(s)
Lt Re→∞=
→∞
=
When
π-j (n-m)
2π
θ , G(s) H(s) 0 e2
= =
When
πj (n-m)2
πθ - , G(s) H(s) 0 e
2
+
= =
From the above two equations we can conclude that the section C2 of Nyquist
contour in s-plane is mapped as circles/circular arc around origin with radius
tending to zero in the G(s) H(s) plane.
Step.5:- In section C3 the value of ω varies from -∞ to 0. The mapping of section C3 is
obtained by letting s = +jω in G(s) H(s) and varying ω from -∞ to 0,
s + jω ω = - to 0 ω - to 0i.e., G(s) H(s) G(jω) H(jω)= ∞= ∞
=
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
231 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
The locus of G(jω) H(jω) as ω is varied from -∞ to 0 will be the G(s) H(s)
contour in G(s) H(s) plane corresponding to section C3 in s-plane. This locus
is the inverse polar plot of G(jω) H(jω). The inverse polar plot is given by the
mirror image of polar plot with respect to real axis.
Step.6:- In section C4 of Nyquist contour has a semicircle of zero radius. Therefore
every point on semicircle has zero magnitude but the argument varies from
π π to .
2 2− + Hence the mapping of section C4 from s-plane to G(s) H(s) plane
can be obtained by letting -jθ
R 0s Lt Re
→= in G(s) H(s) and varying θ from
π π to .
2 2− +
On letting, -jθ
R 0s Lt Re
→= we get
( )jθ
R 0ys Lt Re jθ
R 0
K G(s) H(s)
Lt Re→=
→
=
-jθy e= ∞
When
πj y2
πθ , G(s) H(s) e
2= − = ∞
When
π-j y
2π
θ , G(s) H(s) e2
= = ∞
From the above two equations we can conclude that the section C4 of Nyquist
contour in s-plane is mapped as circles/circular arc in G(s) H(s) plane with
origin as centre and infinite radius.
Note:-
1. If there are no poles on the origin then the section C4 of Nyquist contour will be
absent.
2. If there are poles (for e.g. 8 poles) on imaginary axis then the Nyquist contour is
divided into 8 sections and the mapping is performed section wise.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
232 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
ROOT LOCUS
The Root Locus technique is a powerful tool for adjusting the location of closed
loop poles to achieve the desired system performance by varying one or more system
parameters.
Consider the open loop transfer function of the system,
1 2
KG(s)
s (s p ) (s p )=
+ +
The characteristic equation of the system is
1 2s (s p ) (s p ) K 0+ + + =
The roots of characteristic equation is a function of open loop gain K. When the gain K
is varied from 0 to ∞, the roots of characteristic equation will take different values.
When K=0, the roots are given by open loop poles.
When K=∞, the roots will take the value of open loop zeros.
The path taken by the roots of characteristic equation when open loop gain K is varied
from 0 to ∞ are called root loci.
PROCEDURE FOR THE CONSTRUCTION OF ROOT LOCUS
Step.1:- Locate the poles and zeros of G(s) H(s) on the s-plane.
The root locus branch start from open loop poles and terminate at zeros. The
poles are marked by cross ‘X’ and zeros are marked by small circle ‘O’. The
number of root locus branches is equal to number of poles of open loop
transfer function.
If n = number of poles and m = number of finite zeros, then ‘m’ root locus
branches ends at finite zeros. The remaining (n - m) root locus branches will
end at zeros at infinity.
Step.2:- Determine the root locus on real axis.
Take a test point (left most point) on real axis. Count the total number of
poles and zeros up to right most. If the total number of poles and zeros on the
real axis to the right of this test point is odd number then the test point lies on
the root locus. If it is even then the test point does not lie on the root locus.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
233 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Step.3:- Determine the asymptotes of root locus branches and meeting point of
asymptotes with real axis.
[Asymptote is the line which continually approaches a given curve, but does
not meet it with in a finite distance].
If n = number of poles and m = number of zeros, then (n – m) root locus
branches will terminate at zeros at infinity.
These root locus branches will go along an asymptotic path and meets the
asymptotes at infinity. Hence number of asymptotes is equal to number of
root locus branches going to infinity.
The angle of asymptotes ( )180 2q 1
n - m
± +=
where q 0, 1, 2, 3 ............. (n - m)=
Centroid Sum of poles -Sum of zeros
n - m=
Centroid is the meeting point of asymptote with real axis
Step.4:- Find the break away and break in points. These points lie on real axis or exist as complex conjugate pairs. If there is a
root locus on real axis between 2 poles then there exists a break away point. If
there is a root locus on real axis between 2 zeros then there exists a break in
point. If there is a root locus on real axis between a pole and zero then there
may be or may not be break away or break in point.
Let the characteristic equation be in the form
B(s) K A(s) 0+ =
- B(s) K
A(s)∴ =
The break away and break in point is given by roots of the equation dK
0ds
=
Find the value of s
Substitute the value of s in - B(s)
KA(s)
=
If the value of K is positive and real then only the break in and break away
point s are real otherwise there will not be any break in and break away
point.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
234 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Step.5:- Angle of Departure and Angle of Arrival.
If there is a complex pole then determine the angle of departure from the
complex pole. If there is a complex zero then determine the angle of arrival at
the complex zero.
Angle of departure from a complex pole A
180 -=
Sum of angles of vectors
to the complex pole A
from all other poles
Sum of angles of vectors
to the complex pole A
from all other zeros
+
Angle of arrival at a complex zero A
180 -=
Sum of angles of vectors
to the complex zero A
from all other zeros
Sum of angles of vectors
to the complex zero A
from all other poles
+
For example
From the following figure, Angle of departure [ ] [ ]1 2 3 4 5180 θ θ θ θ θ= − + + + +
From the following figure, Angle of arrival [ ] [ ]1 2 3 4 5180 θ θ θ θ θ= − + + + +
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
235 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
Step.6:- Point of intersection of root locus with imaginary axis.
To find the points where the root loci may cross the imaginary axis is by
putting s jω= in the characteristic equation. Separate the real part and
imaginary part. Two equations are obtained (One by equating real part to
zero and the other by equating imaginary part to zero). Solve the two
equations; give ‘ω’ and ‘K’. The value of ‘ω’ gives the point where the root
locus crosses imaginary axis. The value of ‘K’ gives the value of gain K at this
crossing point. Also this value of K is the limiting value of K for stability of
the system.
Advantages of Root Locus Method
The root locus technique is more advantageous as it gives us following
information:
i) The absolute stability of the system can be predicted from the locations of the
roots in the s-plane.
ii) Limiting range of the values of the system gain ‘K’ can be decided for absolute
stability of the system.
iii) Marginal value of the system gain ‘K’ which makes the system marginally
stable can be determined and the corresponding value of the frequency of
oscillations can be determined from intersection of root locus with imaginary
axis.
iv) Using root locus, value of system gain ‘K’ for any point on the root locus can be
determined, by using magnitude condition.
v) For particular damping ratio of the system, gain ‘K’ can be determined which
helps to design system more correctly.
vi) Root locus analysis also helps in deciding the stability of the control systems
with time-delay.
vii) Gain margin of the system can be determined from root locus.
viii) Phase margin of the system can be determined from root locus.
ix) Relative stability about a particular value of 's 'σ= − can be determined.
x) Information about settling time of the system also can be determined from the
root locus.
Module | 5 F r e q u e n c y R e s p o n s e A n a l y s i s
236 Prepared by Shijin C.S. | St.Joseph’s College of Engineering and Technology, Palai.
REFERENCES
1) Control Systems - Nagoorkani A.
2) Control Systems Engineering - Ramesh Babu
3) Control Systems - U.A. Bakshi & V.U. Bakshi
4) Linear Control Systems - B.S. Mange
5) Problems & Solutions in Control System Engineering - Sivanandam & Deepa
6) Control System Engineering - Nagrath & Gopal
7) Control Systems Theory & Applications - Smarajit Ghosh