measuring the hysteresis loop of the toroidal core using labview to optimize the design of pmsm

Post on 23-Feb-2016

62 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

DEPARTMENT OF INSTRUMENTATION AND CONTROL ENGINEERING . MEASURING THE HYSTERESIS LOOP OF THE TOROIDAL CORE USING LABVIEW TO OPTIMIZE THE DESIGN OF PMSM. AUTHOR: ING. ZDEN ĚK NOVÁK SUPERVISOR: DOC. ING. JAN CHYSKÝ, CSC. Presentation overview. Why to measure hysteresis loop - PowerPoint PPT Presentation

TRANSCRIPT

MEASURING THE HYSTERESIS LOOP OF THE TOROIDAL CORE USING LABVIEW

TO OPTIMIZE THE DESIGN OF PMSM

AUTHOR: ING. ZDENĚK NOVÁKSUPERVISOR: DOC. ING. JAN CHYSKÝ, CSC.

DEPARTMENT OF INSTRUMENTATION AND CONTROL ENGINEERING

Presentation overview

Why to measure hysteresis loopDesign of hysteresis measurementAnalyzing acquired dataApplication of analyzed dataVerification of FEMM analysisConclusion

PMSM

Goal: 250 000 rpmPower output: 5kW

PMSM

sinusoidal filter Control

board

Why to measure hysteresis loopFlux Density [T]

Flux Density [T]In Opposite Direction

Magnetic flux intensity [A/m]

Magnetic flux intensity [A/m]In OppositeDirection

Permanent magnet synchronous motor (PMSM)

Hysteresis loop

WHY TO DO IT

Design of hysteresis measurement

Measuring procedurer

tiNtH

2)(

)( 11 t

duSN

BtB0

22

0 )(1)(

t

duRC

tv0

22 )(1)(

HOW TO DO IT

Toroidal core with winding

First winding Second winding

Workplace

Amplifier and cooling

Signal generator

Power source

integratorDAQ card

PCCoil

Design of hysteresis measurement

Program block diagram

HOW TO DO IT

DAQ Assistant

Writing to Measurement

File

XY Graph

Variables

Design of hysteresis measurement

GUI from LabVIEW

HOW TO DO IT

Analyzing acquired data

Hysteresis loop of the toroidal shape core;

applied current 3 A, applied frequency 250 Hz

HOW TO DO IT

Application of analyzed data

FOR WHAT USE IT

Implementation into FEMM

software

Application of analyzed data

Results of the FEMM analysis

FOR WHAT USE IT

Verification of FEMM analysis

PMSM prototype

FOR WHAT USE IT

Torque of PMSM in FEMM = 0.01... [N.m]

Activating PMSM

Torque of real PMSM= 0.01... [N.m]

For current 4A:

Video na internetu

ConclusionData for B-H curve of the proposed material

were acquired and analyzedB-H characteristic was implemented into

FEMM software and some parameters were verified

Next stepsOptimization of PMSM based on FEMM model Verification of FEMM modelConsidering the possibility of using other

materials and design

SUMMARY

Thank you !Děkuji !Dziękuję !감사합니다 !

Q&A