m2000 huawei tools

Post on 28-Dec-2015

545 Views

Category:

Documents

25 Downloads

Preview:

Click to see full reader

TRANSCRIPT

1 © Nokia Siemens Networks

Confidential

VHA AUS 9th Mar 2012

Huawei Tools Description

2 © Nokia Siemens Networks

Confidential

M2000

3 © Nokia Siemens Networks

Confidential

M2000

The main tasks that can be performed on M2000 are:

To fetch the Dump

To activate Measurement counters

Modify the parameters

To define Custom KPI’s.

To define KPI report template

To fetch KPI reports

To fetch Alarms(both History and Active)

Note: In M2000, KPI reports can be fetched only either by Cell

level or by RNC level.

Hence PRS tool is preferred to fetch the KPI report which is

more user friendly and also similar to the NGR of NSN.

4 © Nokia Siemens Networks

Confidential

M2000: To fetch the Dump

5 © Nokia Siemens Networks

Confidential

M2000: To fetch the Dump

1. Open the MML command window

2. Select the NE type

3. Select the RNC of which the dump is required

4. Type the command “Exp CFGMML” and execute it.(Path and

filename is not mandatory)

5. Open the WebLMT of the respective RNC to download the

configuration file.

a) To open the WebLMT, Go into the Main topology, Right

click on the RNC and select the Maintenance Client.

b) In the main window of Weblmt, Click on the File manager

and browse the file path to download it.

Note: The file downloaded will be in .txt format.

Respective snaps are attached in the next slides.

6 © Nokia Siemens Networks

Confidential

Select the type of NE (RNC or BSC)

Type the Command and

execute

The file will be saved in

the mentioned path. To retrieve the saved file,

please refer the next slide.

M2000: To fetch the Dump// running MML Command

7 © Nokia Siemens Networks

Confidential

M2000: To fetch the Dump// WebLMT

Go into the Topology, Click on Main topology, select the Region and then RNC, right

click on RNC and click on Maintainance client.

Select the File manager

8 © Nokia Siemens Networks

Confidential

M2000: To fetch the Dump// WebLMT// File Manager

Browse the path, select the file, click on the download tab and give the path.

9 © Nokia Siemens Networks

Confidential

M2000: To activate Measurement counters

10 © Nokia Siemens Networks

Confidential

M2000: To activate Measurement counters

1. Go into the performance and click on Measurement

management.

2. Select the appropriate Function Subset and NE.

3. In Measurement status, we can check the active counters

4. In Measurement settings, Select the appropriate Function

set and Function subset, find the counter and activate it (√)

for either 15min or 60 min or 24 hrs

5. Click Apply to activate the Counters

11 © Nokia Siemens Networks

Confidential

M2000: To activate Measurement counters// Measurement Status

In Measurement status, we can check the active counters

12 © Nokia Siemens Networks

Confidential

M2000: To activate Measurement counters// Measurement Settings

In Measurement settings, Select the appropriate Function set and Function subset,

find the counter and activate it (√) for either 15min or 60 min or 24 hrs.

Click Apply to activate the Counters.

13 © Nokia Siemens Networks

Confidential

M2000: To Modify the Parameters

14 © Nokia Siemens Networks

Confidential

M2000: To Modify the Parameters

It is mandatory to know the commands to change the

parameters.

Different parameters belongs to different classes and each

class has its own syntax.

For example:

If need to modify the CPICH power.

1) Lst UPCPICH– to check the existing CPICH power

2) Mod UCELL– to modify the CPICH Tx power(note: the

modified power should be in the max and min limit of CPICH

power. To modify the max and min limit use the command

Mod UPCPICH.

15 © Nokia Siemens Networks

Confidential

MOD UCELL

LST UPCPICH

M2000: To Modify the Parameters // e.g. Modify CPICH power

16 © Nokia Siemens Networks

Confidential

M2000: To define Custom KPI’s

17 © Nokia Siemens Networks

Confidential

M2000: To define Custom KPI’s

1. Customized KPI’s can be created using M2000. Click on

Performance and select Custom Counter management.

2. In the Function subset, select the BSC or RNC.

3. To create a new report, click on the tab Add.

4. Give some name for custom counter, Units, Select the

Function set and Function subset. (note: Pay attention to

select Function set and Function subset, we can only find

the counter in related Function set and Function subset)

5. From the Function set, select the counters, use the

arithmetic operations available to add, subtract, multiply.. In

between the counters.

6. Click Apply and then ok

Note: Since we are not using M2000 in VHA-AUS project for

performance management this may not require.

“GP” of mathematical operator in the window is

measurement period, its unit is minute;

For RNC KPI, we can only select counters of RNC wise;

for cell KPI, we can only select counter of cell wise, M2000 can’t

support gather function.

18 © Nokia Siemens Networks

Confidential

M2000: To define Custom KPI’s// Adding a new KPI// e.g. for SHO attempts

Some Name for

identification

Units

Final formula can be seen in this window.

19 © Nokia Siemens Networks

Confidential

M2000: To define KPI report template

20 © Nokia Siemens Networks

Confidential

M2000: To define KPI report template

1. Go into the performance select the query result

2. Select New query

3. Select same “Function Subset” in directory tree of new

window as that of defined KPI formula. We can only select

unique “Function Subset” in one report, so define all

counters of a report in the same Function Subset. Then

select measurement object in the window of “Object

Settings.

4. In the object settings, Select the Objects (RNC, BSC or Cell)

5. In the Counters settings, select the counters that need to be

fetched.(the counters can be system counters or the

customized one)

6. In time conditions, select the time for which the KPI need to

be fetched.

7. Click on Save template and save it with appropriate name.

21 © Nokia Siemens Networks

Confidential

M2000: To define KPI report template // Adding a new KPI template

There is some issue with window size when new query is selected. So no more

snaps can be attached for this class

22 © Nokia Siemens Networks

Confidential

M2000: To fetch KPI reports

23 © Nokia Siemens Networks

Confidential

M2000: To fetch KPI reports

1. Go into the performance select the query result

2. Select the customized KPI template, right click, select the

Query results and then click on any of the time lines

specified. (note: if the report is required for some other

measurement period select Specific)

3. Once the report is generated click on save tab and save it to

local PC.

Note: For VHA AUS there is some restriction in M2000 for

fetching KPIs. PRS is preferred for performance

management.

24 © Nokia Siemens Networks

Confidential

M2000: To fetch KPI reports

25 © Nokia Siemens Networks

Confidential

M2000: To fetch Alarms(both History and Active)

26 © Nokia Siemens Networks

Confidential

M2000: To fetch Alarms

Active alarms

1. Go into the monitor select the Browse alarm list

2. In the Basic settings, select the Severity, status and type

3. In Alarm source, select the NE type and click ok.

History Alarms:

1. Go into the monitor and select the Query Alarm logs.

2. Follow the same procedure as mentioned in the Active

alarms. Mention the history period for which the alarms are

fetched.

27 © Nokia Siemens Networks

Confidential

M2000: To fetch Active Alarms

28 © Nokia Siemens Networks

Confidential

M2000: To fetch Active Alarms

Select the Object, i.e. RNC or NodeB or Cell.

29 © Nokia Siemens Networks

Confidential

End