INTERVENTIONAL

www.dextronix.com(866) 744-3427

PRODUCTS

Placement: Trachea, self-expanding Configuration: Braided stent loaded on delivery system, sterile Flexibility: Highly elastic and strong radial forces Visibility: Radiopaque stent and delivery system MRI compatible: Yes Delivery System: Included - 47cm working length

www.dextronix.com

Nitinol Tracheal Stent

Width x Length Product No. Width x Length Product No. Width x Length Product No.

08 mm x 20 mm 231047-008020 12 mm x 40 mm 231047-012040 14 mm x 90 mm 231447-014090

08 mm x 50 mm 231047-008050 12 mm x 50 mm 231047-012050 14 mm x 100 mm 231447-014100

08 mm x 60 mm 231047-008060 12 mm x 60 mm 231047-012060 14 mm x 110 mm 231447-014110

08 mm x 70 mm 231047-008070 12 mm x 70 mm 231047-012070 14 mm x 120 mm 231447-014120

08 mm x 80 mm 231047-008080 12 mm x 80 mm 231047-012080 16 mm x 80 mm 231447-016080

08 mm x 90 mm 231047-008090 12 mm x 90 mm 231047-012090 16 mm x 90 mm 231447-016090

10 mm x 20 mm 231047-010020 12 mm x 100 mm 231047-012100 16 mm x 100 mm 231447-016100

10 mm x 50 mm 231047-010050 12 mm x 110 mm 231047-012110 16 mm x 120 mm 231447-016120

10 mm x 60 mm 231047-010060 12 mm x 120 mm 231047-012120 18 mm x 80 mm 231447-018080

10 mm x 70 mm 231047-010070 14 mm x 60 mm 231447-014060 18 mm x 90 mm 231447-018090

10 mm x 80 mm 231047-010080 14 mm x 70 mm 231447-014070 18 mm x 100 mm 231447-018100

10 mm x 90 mm 231047-010090 14 mm x 80 mm 231447-014080 18 mm x 120 mm 231447-018120

Braided Stent Design: Enhanced biocompatibilityOptimized to withstand high radial compression forcesSuper elastic, highly durable, re-constrainable to 95%

Delivery System: Simple and controlled stent positioning and placementAccidental stent release prevented by built-in, peel away safety mechanism

(866) 744-3427All products are for veterinary use

only. Not for human use.

www.dextronix.com

Conical Tracheal Stent

Cervical/Thoracic x Length Product No.

10/8.5 x 60 mm 231047-108560

10/8.5 x 70 mm 231047-108570

10/8.5 x 80 mm 231047-108580

12/10 x 60 mm 231047-121060

12/10 x 70 mm 231047-121070

12/10 x 80 mm 231047-121080

12/10 x 90 mm 231047-121090

14/12 x 60 mm 231047-141260

14/12 x 70 mm 231047-141270

14/12 x 80 mm 231047-141280

14/12 x 90 mm 231047-141290

(866) 744-3427

Placement: Trachea, self-expandingMaterial: Nitinol, braided Configuration: Stent loaded on delivery system, sterile Flexibility: Highly elastic and strong radial forces Visibility: Radiopaque stent and delivery system MRI compatible: YesDelivery System: Included: 47cm working lengthStent Design: Enhanced biocompatibility

Optimized to withstand high radial compression forcesSuper elastic, highly durable, re-constrainable to 95%

Delivery System: Simple and controlled stent positioning and placement Accidental stent release prevention through built-in, peel away safety mechanism

All products are for veterinary use only. Not for human use.

Atraumatic Stent Endings

www.dextronix.com

Vena Cava Stent

Length x Diameter Product No.

18 mm x 80 mm 231080-018080

20 mm x 80 mm 231080-020080

22 mm x 80 mm 231080-022080

24 mm x 80 mm 231080-024080

26 mm x 80 mm 231080-026080

28 mm x 80 mm 231080-028080

28 mm x 100 mm 231080-028100

30 mm x 100 mm 231080-030100

(866) 744-3427

Placement: Vena Cava, self-expanding Configuration: Laser-cut and polished, preloaded Radio Markers: Tantalum markers (optional)MRI compatible: Yes Delivery System: Included – 80 cm Length, 10 Fr, sterile

All products are for veterinary use only. Not for human use.

www.dextronix.com

Nitinol Urethra Stent

Width x Length Product No.

06 mm x 40 mm 230670-006040

06 mm x 60 mm 230670-006060

08 mm x 40 mm 230670-008040

08 mm x 60 mm 230670-008060

08 mm x 80 mm 230670-008080

10 mm x 40 mm 230670-010040

10 mm x 60 mm 230670-010060

10 mm x 80 mm 230670-010080

12 mm x 60 mm 230670-012060

12 mm x 80 mm 230670-012080

14 mm x 80 mm 230670-014080

(866) 744-3427

Placement: UrethraConfiguration: Laser-cut and polished, preloaded & sterileFlexibility: Highly elastic, kink resistant & strong radial forcesRadio Marker: Tantalum markers at proximal & distal end of stent,

Radiopaque Platinum markers on the inner catheter for excellent visibility during Fluoroscopy

MRI compatible: YesDelivery System: Included - 65cm Length, 8 French* for guide wire

0.018”, (guide wire not included)

All products are for veterinary use only. Not for human use.

www.dextronix.com

Covered Nitinol Urethra Stent

Width x Length Product No.

06 mm x 40 mm 230856-006040

06 mm x 60 mm 230856-006060

06 mm x 80 mm 230856-006080

08 mm x 40 mm 230856-008040

08 mm x 60 mm 230856-008060

08 mm x 80 mm 230856-008080

10 mm x 60 mm 230856-010060

10 mm x 80 mm 230856-010080

12 mm x 60 mm 230856-012060

12 mm x 80 mm 230856-012080

14 mm x 80 mm 230856-014080

(866) 744-3427

Placement: Urethra Configuration: Self-Expanding braided Nitinol Stent with polymeric cover film Flexibility: Super-elastic, strong polymer cover preventing tumor in-growthVisibility: Excellent visibility during Fluoroscopy MRI compatible: Yes Delivery System: Included - 65cm Length, 8 Fr diameter 0.018” guide wire (not

included) Simple and controlled stent positioning and placementFully re-constrainable prior to deploymentAccidental stent release prevented by peel away safety mechanism

All products are for veterinary use only. Not for human use.

www.dextronix.com

Sizing Catheter

(866) 744-3427

Width x Length Product No.

8 Fr/50 cm 230001-080050

All products are for veterinary use only. Not for human use.

Placement: Esophagus, urethraFunction: Measuring/sizing catheter designed for radiographyConfiguration: Radio markers

Reusable measuring catheter with highly visible radio markers in10mm increments. 50cm length – 8 Fr

www.dextronix.com

Flexible Nitinol Ureteral Stent

(866) 744-3427

2.0 Fr DiameterImproves handling and placement accuracyDrain inside and alongside the helix Highly visible in fluoroscopy

Width x Length Product No.

2.0 Fr x 8 cm 232110-020080

2.0 Fr x 10 cm 232110-020010

2.0 Fr x 12 cm 232110-020012

2.0 Fr x 14 cm 232110-020014

2.0 Fr x 16 cm 232110-020016

All products are for veterinary use only. Not for human use.

Placement: Ureter Configuration: Spiral laser-cut, kink-proofMaterial: Nitinol, radiopaquePusher: Conical tip, includedGuide Wire: Requires 0.018” Nitinol

hydrophilic, not included

www.dextronix.com

Ureteral Polyurethane Stent

Diameter Length Coil Diameter Product No.

2.4 Fr 6 cm 6 mm 232110-024060

2.4 Fr 8 cm 6 mm 232110-024080

2.4 Fr 10 cm 6 mm 232110-024100

2.4 Fr 12 cm 6 mm 232110-024120

2.4 Fr 14 cm 6 mm 232110-024140

2.4 Fr 16 cm 6 mm 232110-024160

4.0 Fr 12 cm 8 mm 232110-040120

4.0 Fr 14 cm 8 mm 232110-040140

4.0 Fr 16 cm 8 mm 232110-040160

4.0 Fr 18 cm 8 mm 232110-040180

4.0 Fr 20 cm 8 mm 232110-040200

4.0 Fr 24 cm 8 mm 232110-040240

4.8 Fr 16 cm 10 mm 232110-048160

4.8 Fr 18 cm 10 mm 232110-048180

4.8 Fr 20 cm 10 mm 232110-048200

4.8 Fr 24 cm 10 mm 232110-048240

6.0 Fr 18 cm 12 mm 232110-060180

6.0 Fr 22 cm 12 mm 232110-060220

6.0 Fr 24 cm 12 mm 232110-060240

6.0 Fr 28 cm 12 mm 232110-060280

6.0 Fr 30 cm 12 mm 232110-060300

6.0 Fr 32 cm 12 mm 232110-060320

(866) 744-3427

Placement: Ureter Configuration: Fenestration in coils and shaftMaterial: Biocompatible Polyurethane, graduated, radiopaquePusher/Dilator: Conical tip, includedGuide Wire: Requires 0.018” Nitinol hydrophilic, not included

All products are for veterinary use only. Not for human use.

Nitinol Guidewire

Diameter Length Tip Coating Product No.

0.018” 50 cm Angled Hydrophilic 239114-018050

0.018” 50 cm Straight Hydrophilic 239114-018051

0.018” 100 cm Angled Hydrophilic 239114-018100

0.018” 100 cm Straight Hydrophilic 239114-018101

0.018” 150 cm Angled Hydrophilic 239114-018150

0.018” 150cm Straight Hydrophilic 239114-018151

0.035” 150 cm Angled Hydrophilic 239114-035150

0.035” 150 cm Straight Hydrophilic 239114-035151

All products are for veterinary use only. Not for human use.

Material: Nitinol, non-twistingNon-traumatic soft tipHigh visibility in Fluoroscopy

(866) 744-3427www.dextronix.com

Diameter Snare Length Snare Shaft Diameter Product No.

7 mm 60 cm 1.9 Fr 238607-019060

12 mm 60 cm 1.9 Fr 238612-019060

16 mm 60 cm 1.9 Fr 238616-019060

30 mm 60 cm 1.9 Fr 238630-019060

7 mm 120 cm 1.9 Fr 238607-019120

12 mm 120 cm 1.9 Fr 238612-019120

16 mm 120 cm 1.9 Fr 238616-019120

30 mm 120 cm 1.9 Fr 238630-019120

Loop

Nitinol LoopFunction: Foreign object removal, gastrointestinal tractMaterial: Nitinol, extremely flexible

All products are for veterinary use only. Not for human use.

(866) 744-3427www.dextronix.com

Diameter x Length Product No.

7 Fr x 160 cm 238701-070160

7 Fr x 250 cm 238701-070250

Tractor

All products are for veterinary use only. Not for human use.

Function: Gastrointestinal, foreign object removalMaterial: Nitinol, excellent torque control Basket: Asymmetrical design optimized for extracting stones

Variable basket diameter adapts to irregular shapesFeatures: Compatible with most standard scopes

Custom lengths available upon requestExtracts golf balls and other difficult to extract objects

Golf Ball Extractor

(866) 744-3427www.dextronix.com

Placement: Kidney, bladder Material: Nitinol, extremely flexible/durable Basket: Manufactured from continuous round Nitinol wire

for a non-traumatic application Shaft: No critical joints between the basket and shaft Grip: Basket can be rotated via the handle –

approximately 1 to 1 toque for optimal steering

Tipless Stone Retrieval Basket

Diameter x Length x Basket Diameter Product No.

1.9 Fr x 60 cm x 12 mm 238012-119060

1.9 Fr x 60 cm x 16 mm 238016-119060

1.9 Fr x 120 cm x 06 mm 238006-119120

1.9 Fr x 120 cm x 08 mm 238008-119120

1.9 Fr x 120 cm x 10 mm 238010-119120

1.9 Fr x 120 cm x 12mm 238012-119120

1.9 Fr x 120 cm x 16 mm 238116-119120

5.0 Fr x 300 cm x 16 mm 238116-050300

All products are for veterinary use only. Not for human use.

(866) 744-3427www.dextronix.com

Laser Stone Retrieval Basket

Diameter x Length x Basket Diameter Product No.

4.0 Fr x 75 cm x 12 mm 238212-040075L

4.0 Fr x 75 cm x 16 mm 238216-040075L

4.0 Fr x 120 cm x 12 mm 238212-040120L

4.0 Fr x 120 cm x 16 mm 238216-040120L

Function: Nitinol basket for laser fragmentation and bladder stone extraction, sterile

Material: Nitinol, extremely flexibleLaser: Central laser channel accepts laser fibers up to 0.5 mm

diameter Grip: Basket can be rotated via the handle –

Simple one-hand use and control

-L

All products are for veterinary use only. Not for human use.

(866) 744-3427www.dextronix.com

Description Product No.

Retractor w/ manipulator, min trocar size 8mm (1 device per unit) VSL07B01

Retractor w/ manipulator, min trocar size 8mm (3 devices per unit) VSL07B03

Retractor w/ introducer, min trocar size 10mm (5 devices per unit) VSL10A05

Lifter

All products are for veterinary use only. Not for human use.

Function: Disposable, dynamic organ suspension system for laparoscopic proceduresFeatures: “Hands free”, no change of instruments required for manipulation

Fully repositionable and adjustable

Dynamic Organ Suspension

(866) 744-3427www.dextronix.com

All products are for veterinary use only. Not for human use.

(866) 744-3427www.dextronix.com

Dextronix, Inc.,11811 N Tatum Blvd, #3031Phoenix, Arizona 85028U.S.A.

PRICING: Please contact us to receive price information. We ship to most countries and most products are stock items shipping same or next day.CUSTOM DESIGNS: We will manufacture custom designs, shapes and lengths and sizes at affordable prices for you, please inquire.QUALITY: All products are exclusively made for Dextronix by leading medical device manufacturers in Germany, France & Switzerland. They meet the highest standards in reliability, safety and quality as found in human medicine.