www.gsinstrument.com

December 22, 2012

GS Instruments Co., Ltd.

Confidential and proprietary to GS Instruments Co., Ltd.

Copying, reproduction or distribution this information is strictly prohibited without prior written authorization from GS Ins truments Co., Ltd..

Installation & Operational Guide

Version 2.9

LOGO

www.gsinstrument.com 2

INTRO

Before Installation TMB, Please check basic points.

1) O/S: Window XP, Window 7

2) Pre-testing of Remote Access: Between Local/Remote GUI and TMB-9100

3) Turn off BTS first before starting your works

4) Turn on TMB first after finishing your works

5) Calculate and consider the output power of BTS and Input signal level of TMB-9100

6) TMB-9100 is very high powered RF so that Be careful when you set TMB parameters.

7) Remote GUI: Click “MAIN" button (Refresh) after getting SMS from TMB-9100

8) Local GUI: Check “Refresh” for renewal information.

9) After turn on TMB, please wait 5- 10minutes for warming

LOGO

www.gsinstrument.com 3

TMB-9100 Configuration

LOGO

www.gsinstrument.com 4

Step 1. TMB Installation (Before)

* Preparation

Note Book (1) USB to RS-232C Cable (1) Molex 2pin to AC/DC Adaptor 6V 2A(1)

Connect each cable to MCU of TMB

LOGO

www.gsinstrument.com 5

Step 1. TMB Installation (Before)

* Open “ Local GUI”

LOGO

www.gsinstrument.com 6

Step 1. TMB Installation (Before)

• Check F/W version: 2.9 • Check Initial parameter setting

LOGO

www.gsinstrument.com 7

Step 1. TMB Installation (Before)

* Set “Server Min No” through Local GUI (Mandatory)

LOGO

www.gsinstrument.com 8

1) Enter Site Name 2) TMB SIM Card Number 2) Enter Alarm Reporting upto 4 number

Step 1. TMB Installation (Before)

LOGO

www.gsinstrument.com 9

Step 1. TMB Installation (Before)

* Insert SIM Card to MCU of TMB

Please remember the number of SIM

LOGO

www.gsinstrument.com 10

Step 2. TMB Installation

* Install TMB at right position

LOGO

www.gsinstrument.com 11

Step 3. DC Cable Installation

1) Install DC cable from BTS room to the location of TMB 2) DC Power Supply Recommendation: +48V 40A 3) TMB Site: +48 +/- 15%, Total Electric Power: 1,300W

LOGO

www.gsinstrument.com 12

Step 3. DC Cable Installation

4) Connect DC jack with DC cable

B: -48Volt, A: Ground

Local electrical code should be followed in connecting DC power to the MCPA 9100 system. In order

to connect DC Cable, connect cable to DC INPUT port, and then connect the other end to DC Power

Source. The DC input power cable is illustrated in Figure 1.

The DC cable from the base station is connected to the DC INPUT port as shown in Figure 1. Use

two AWG08 cable to the DC INPUT through bottom interface panel. The DC cable should be

protected with a 40-amp minimum circuit breaker.

Figure 1 DC Input Jack

LOGO

www.gsinstrument.com 13

Step 3. DC Cable Installation

Step1: Preparation

Step2: Preparation

Step3: Top view

Step4: Insert AG8 wires & Contraction Tube

LOGO

www.gsinstrument.com 14

Step 3. DC Cable Installation

Step5: Strip the wire

Step6: Pre-soldering (Cable & Hole)

Step7: Soldering fully

Step8: Apply heat to the contraction tube

LOGO

www.gsinstrument.com 15

Step 3. DC Cable Installation

Step9: Apply heat to contraction tube

Step10: Combine connectors

Step11: Apply heat to the tube

LOGO

www.gsinstrument.com 16

Step 4. Power Off BTS

1) Turn off the power amplifier (A Sector) of BTS

LOGO

www.gsinstrument.com 17

Step 5. Cable Connection

1) Connect Jumper cable for each path 2) Shielding for water-proof at cable connector

BTS ANTENNA

Feeder

Feeder

Feeder

Feeder

Jumper

LOGO

www.gsinstrument.com 18

3) Connect Jumper cables to each port

Step 5. Cable Connection

LOGO

www.gsinstrument.com 19

Step 6. TMB Setting – Remote Access

Remote GUI

Caution: Please reinstall modem box and SIM card if responding is not good

1) Please disconnect and take out the SIM card and then plug in again 2) Please change your com port in your pc

Please wait 5-10mins after turn on the TMB while optimizing

This version is optimized with Window XP and Window 7.

LOGO

www.gsinstrument.com 20

1) Execute TMB-9100_Remote GUI

2) Connect Modem Box to USB Port of your PC

Step 6. TMB Setting – Remote Access

LOGO

www.gsinstrument.com 21

3) Check & Set Com Port - Check “Device manager Pin your PC

4) Click “Main” button

6) Click “Modem Check” button

5) Set “Sever Min No”

Step 6. TMB Setting – Remote Access

LOGO

www.gsinstrument.com 22

7) Click “ Status Req”, “Info Req”, and “Control”

Step 6. TMB Setting – Remote Access

LOGO

www.gsinstrument.com 23

8) Click “Refresh” or “Main” button.

If Alarm LEDs are not updated after receiving SMS from TMB, please click “Main” button

[Before]

[After]

Step 6. TMB Setting – Remote Access

LOGO

www.gsinstrument.com 24

9) “Status Request” information

Step 6. TMB Setting – Remote Access

LOGO

www.gsinstrument.com 25

10) “Info Request” information

Step 6. TMB Setting – Remote Access

LOGO

www.gsinstrument.com 26

11) Control button – Set parameters

Step 6. TMB Setting – Remote Access

LOGO

www.gsinstrument.com 27

Step 7. Turn on TMB

LOGO

www.gsinstrument.com 28

Step 8. Turn on BTS

LOGO

www.gsinstrument.com 29

Step 9. Input Signal Level Checking

1) Check Input Signal Level Caution: Please Consider and Calculate the input signal level and loss.

LOGO

www.gsinstrument.com 30

2) Alarm Checking

ALARM CHECK

Step 9. Input Signal Level Checking

LOGO

www.gsinstrument.com 31

Step 10. TMB Gain Setting

1) Check Output Power of GUI (TMB Gain 0)

* Generally you can see the total output power for Signaling channel on the top of the tower.

LOGO

www.gsinstrument.com 32

2) TX Output Power setting (Reference)

TX output power setup table – Below table is for reference in input power variation +/-1dB

BTS Max Output Power Output Power

(TMB Gain 0dB) TMB9100 Gain Setting GUI Gain Control MCPA9100Output Power

2CH 80W 49.3dBm 43 8 12 51dBm

4CH 87W 49.4dBm 42 9 11 51dBm

8CH 80W 49.3dBm 41 10 10 51dBm

Step 10. TMB Gain Setting

* Max Output power was calculated according to Power Sharing of BTS

LOGO

www.gsinstrument.com 33

- LNA Gain Setting * According to a site, it can be changed. It is basic setting of TMB-9100

1) TMB Output Power – Input signal power = TMB TX Gain or Check the GUI 2) RX & DIV Gain

NO TX GAIN RX GAIN DIV GAIN Remark

1 1 – 10dB 12dB 12dB

2 11 – 20dB 14dB 14dB

Step 11. TMB Gain Setting

LOGO

www.gsinstrument.com 34

- Check TX / RX / DIV Gain (LNA Gain can be higher than TX Gain) - Check output power of TMB - Check Alarm LED

Gain setting

Alarm Checking

ALC Mode OFF

Output Power Check

Step 11. TMB Gain Setting

LOGO

www.gsinstrument.com 35

Step 11. TMB Setting – Others

1) Enter Site Name 2) TMB SIM Card Number 2) Enter Alarm Reporting upto 4 number

LOGO

www.gsinstrument.com 36

Step 12. Check output Power

1) Check output power of TMB with spectrum analyzer 2) connection with coupling port of TMB

TX Coupling port (-40 dB +/- 1dB) using a spectrum analyzer. And Add jumper cable loss. To protect the spectrum analyzer, use TX coupling port -20 dB fixed attenuator.

LOGO

www.gsinstrument.com 37

Step 12. Check output Power

• According to traffics, the output power will be fluctuated. • Please check total power of TMB

LOGO

www.gsinstrument.com 38

Appendix 1: TMB Operation

1. Auto Attenuation Function - TMB has automatic function to protect its circuit while output power is higher than 52dBM in traffic increasing time - The reduction of TX Gain will be reduced and the step is 0.5dB 2. ALC Mode - In high traffic sector, please set ALC Mode On and ALC Level. - Max ALC level range is from 40 to 51dB. - It will automatically optimize the TX Gain with 0.5dB step. 3. Auto Recovery Algorithm - TMB will alive automatically if TMB has Overpower alarm after 3minutes. 4. TMB Power Detection time - 100ms - It will provide real time measurement but the accuracy will be less than Spectrum Analyzer. 5. SMS delay or missing - While MCU is working with other job, it cannot update or report alarms and control command. - Try again to set or check TMB unit. - After setting TMB, it takes time to report new information. Tray again to get new information. - Responding time for Control command: 5sec to set (general environment) - Responding time for Request command: 10-20sec (general environment)

LOGO

www.gsinstrument.com 39

Appendix 2: Remote GUI & Modem Box

1. Local GUI and Remote GUI are optimized for O/S of Window 7 and XP. Other version of O/S cannot be suitable for GUIs and Remote Access. 2. Modem Box cannot be compatible for USB port of your PC. Please use other USB Port or your PC if there are several Pop-up menu for disconnection. 3. If the communication between GUI and Modem box are disconnected, Pop up-menu can be generated. Please click “ok” and check Modem 4. If you order several message in case that you cannot receive replies from TMB or other purpose, this modem can handle every requests from you and TMB so that this message will be come. Please restart “Remote GUI” for solving the matter or turn off /on the modem box. 5. In few case, SIM card error will be happened. You connect and check everything is OK but if the communication between GUI and TMB is not proper, Please check SIM Card connection or SIM Card Error. 6. In Rare cases, the received SMS from TMB cannot be erased in Modem Box so that it can make unstable Remote Access. Please check “SMS Clean” button

Checking Points

LOGO

www.gsinstrument.com 40

* Input Coupler: 1) TX/RX Signal Detect 2) GSM Modem Coupling

* By Pass Relay: 1) Main path bypass (TX/RX signal )

* By Pass Relay1: 1) DIV path bypass (RX1 signal )

* Cavity Filter: 1) TX/RX IN/OUT, 2) DIV IN/OUT

* Cavity Filter 2 1) TX/RX IN/OUT

* A Module 1) TX Variable Attenuation

* MCPA: 1) Multi carrier power amplifier 150W

* Main LNA: RX Low Noise Amplifier

* DIV LNA: Diversity Low Noise Amplifier

* Arrestor: 1) TX/RX path

* I/O Board: to control and manage Power Supply & Control Signal, Alarm Signal, and Detected information from/to all Modules except of MCPA

* DC Power Supply DC to DC Converter that outputs DC27V, DC12V, and DC9V

Appendix 1: TMB-9100 Modules