handling
Post on 22-Jan-2016
6 Views
Preview:
DESCRIPTION
TRANSCRIPT
1 - ConductorBare copper :Flexible-class 5IEC 228
2 - InsulationPVC
3 - OutersheathSpecial PVCcolour : black
N.B.:Colours and other constructional detailscan be according to customer specialrequirements.Core IdentificationAccording to customer requirementsusually as follows :cables < 6 cores : color codecables > 5 cores : printed numbersgreen / yellow core also availableSheath marking- Name of manufacturer- Metric marking- Size- Other : as per customer requirements
These cables are in accordance withCENELEC harmonization document HD359 / VDE 0281 / BS 6977 / CEI 20 - 25 /NF C 32 - 202 /SR C 36 / NEN 3623 / UNE 21 153ApplicationThese cables are used for festoons,trolleys, overhead cranes inside oroutside.
CONSTRUCTION
CENELEC HD 359 S9IEC 227 Part 6Maximum conductortemperature : 70o C
11.1 450 / 750 V Flat cables
HANDLING & LIFT CABLES11
1
3
2
40
4 G 1.5
4 G 2.5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50
4 G 70
4 G 95
5 G 1.5
5 G 2.5
7 G 1.5
7 G 2.5
7 G 4
8 G 1.5
8 G 2.5
9 G 1.5
10 G 1.5
12 G 1.5
12 G 2.5
12 G 4
16 G 1.5
18 G 1.5
15 x 5
18.5 x 5.7
21 x 6.5
23 x 7
28.8 x 9
36.8 x 10.8
45.5 x 13.5
50.5 x 14.8
56 x 16.5
63 x 18
72.5 x 20.5
18 x 5
22 x 5.7
26 x 5
32.3 x 5.7
40 x 6.8
29 x 5
34.5 x 5.7
32 x 5
35 x 5
40.5 x 5
50.5 x 5.7
57 x 6.8
53.5 x 5
58 x 5
20
27
36
48
63
85
112
138
168
213
258
18
25
15
20
25
14
20
12
12
11
16
20
10
8
20.2
12.3
7.8
5.3
3.2
2.0
1.3
0.97
0.74
0.55
0.42
20.2
12.3
20.2
12.3
7.8
20.2
12.3
20.2
20.2
20.2
12.3
7.8
20.2
20.2
40
45
55
65
75
80
100
120
130
140
200
40
45
40
45
55
40
45
40
40
40
45
55
40
40
150
210
300
385
620
990
1 550
2 030
2 650
3 650
4 550
180
260
260
380
550
300
405
330
360
420
620
880
560
620
Cables(mm2)
Bendingradius( mm )
Permissiblecurrent rating
(A) (1)
(cos ϕ = 0.8)Voltage drop(V/Ax km)
Overalldimensions
( mm )
Weightapprox.
(Kg/Km)
Technical Data
Specifications can change according to customer requirements
➀ Ambient temperature : 30oC• Other sizes are also available
450 / 750 V FLAT CABLES
41
1 - ConductorBare copper :Flexible-class 5IEC 228
2 - InsulationTPR(thermoplastic rubber)
3 - OutersheathTPRcolour : black
N.B.:Colours and other constructional detailscan be according to customer specialrequirements.Core IdentificationAccording to customer requirementsfrom 6 cores : printed numbers with 1green / yellow coreSheath marking- Name of manufacturer- Metric marking- Size- Other : as per customer requirementsVoltage testBetween conductors3500 V - 50 HzApplicationThese cables are used for hoistingsystems, festoons, trolleys, overheadcranes, out doors with low temperature.
CONSTRUCTION
Maximum conductortemperature : 85o C
11.2 - 0.6 / 1 KV Thermoplastic rubber flat cables- Halogen free- Low smoke
HANDLING & LIFT CABLES11
1
3
2
42
4 G 1.5
4 G 2.5
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50
4 G 70
8 G 1.5
8 G 2.5
12 G 1.5
12 G 2.5
16 x 5
19 x 5.7
21 x 6.5
23.5 x 7
29 x 9
35 x 10.4
45.5 x 13.5
50.5 x 14.8
56 x 16.5
63 x 18
29 x 5
35 x 5.7
41 x 5
51 x 5.7
22
30
40
52
70
95
127
157
190
242
16
25
12
20
22.1
13.3
8.3
5.5
3.3
2.1
1.3
0.97
0.74
0.55
22.1
13.3
22.1
13.3
50
55
65
70
90
105
135
150
165
180
50
55
50
55
110
170
250
330
550
800
1 350
1 800
2 400
3 250
220
330
320
490
Cables(mm2)
Bendingradius( mm )
Permissiblecurrent rating
(A)
(cos ϕ = 0.8)Voltage drop(V/Ax km)
Overalldimensions
( mm )
Weightapprox.
(Kg/Km)
Technical Data
Specifications can change according to customer requirements
➀ Ambient temperature : 30oC• Other sizes are also available
0.6 / 1 KV THERMOPLASTIC RUBBER FLAT CABLES
43
1 - ConductorBare copper :Flexible-class 5IEC 228
2 - InsulationSpecial PVC
3 - Outer sheathSpecial PVCcolour : black
N.B.:Colours and other constructional detailscan be according to customer specialrequirements.Core IdentificationPrinted numbers with 1 yellow / greencoreLaying upIn parallel by group from 2 to 5 coreswith a striping thread in each group.Sheath marking- Name of manufacturer- Metric marking- Size- Other : as per customer requirementsApplicationThese cables are used as pendant liftcables where freely suspended lengthmust not exceed 45 meters and thetravelling speed must not exceed 4m/Sfor ambient temperature between -15
oC
to 40oC.
This standard allows to include 3telecomminication units in centralposition (copper pairs or quads screenedor unsceened, coaxial, optical fibers).
CONSTRUCTION
CENELEC HD 359 S3 DraftMaximum conductortemperature : 70o C
11.3 - 300 / 500 V Flat lifts cables
HANDLING & LIFT CABLES11
1
3
2
44
12 G 0.75
16 G 0.75
18 G 0.75
20 G 0.75
24 G 0.75
12 G 1
16 G 1
18 G 1
20 G 1
24 G 1
29.4 x 3.7
38.8 x 3.7
43.3 x 3.7
48.3 x 3.7
57.7 x 3.7
31 x 3.9
41 x 3.9
48.8 x 3.9
51.1 x 3.9
61.1 x 3.9
34.5 x 4.5
45.5 x 4.5
51 x 4.5
57 x 4.5
68 x 4.5
36 x 4.6
47 x 4.6
51.7 x 4.5
59 x 4.6
70 x 4.6
6
5
5
4
4
8
7
6
6
6
280
360
400
440
520
320
420
470
500
610
Cables(mm2)
Permissiblecurrent rating
(A)➀
Weightapprox.
(Kg/Km)Min.( mm )
Max.( mm )
Technical Data
Specifications can change according to customer requirements
➀ Ambient temperature : 30oC• Other sizes are also available
Overall dimensions
300 / 500 V FLAT LIFT CABLES
45
1 - ConductorBare copper :Flexible-class 5IEC 228
2 - InsulationPVC
3 - OutershearthPVCcolour : black
4 - Strain bearing membersGalvanized steel
N.B.:Colours and other constructional detailscan be according to customer specialrequirements.Core IdentificationPrinted numbers with 1 yellow / greencoreLaying upIn parallel by group from 2 to 5 coreswith a striping thread in each group.Sheath marking- Name of manufacturer- Metric marking- Size- Other : as per customer requirements
They are in accordance with CENELECharmonization document HD 359 andvarious national standards (CEI 2025, BS6977, NF C 32-202, VDEO 281, UNE21153)ApplicationWith strain bearing members, thesecables can be used for freely suspendedlength up to 120 meters and the travellingspeed must not exceed 1.6m/s.
CONSTRUCTION
CENELEC HD 359 S2Maximum conductortemperature : 70o C
11.4 - 300 / 500 V Flat lifts cables
HANDLING & LIFT CABLES11
1
3
2
4
46
24 G 0.75
24 G 1
68.5 x 3.7
72.5 x 3.9
75 x 4.3
78.2 x 4.5
4
6
600
690
Cables(mm2)
Permissiblecurrent rating
(A)➀
Weightapprox.
(Kg/Km)Min.( mm )
Max.( mm )
Technical Data
Specifications can change according to customer requirements
➀Ambient temperature : 30oC• Other sizes are also available
Overall dimensions
300 / 500 V FLAT LIFT CABLES
47