g60 patient monitor
Post on 21-Feb-2018
237 Views
Preview:
TRANSCRIPT
7/24/2019 G60 Patient Monitor
http://slidepdf.com/reader/full/g60-patient-monitor 1/2
G60 Modular Patient Monitor ● Plug-and-play modular design provides patient care exibility
● 12.1” color TFT display
● Maximum 8 waveform display
● 7-lead ECG or 12-lead ECG simultaneous display
● ST and arrhythmia analysis
● Hemodynamic, Oxygenation, Ventilation, Drug Dose Calculations
● OxyCRG dynamic trend display
● Bed-to-bed view
● Applications from neonate to adult
● LAN networking capability to UT4800 central monitoring system
7/24/2019 G60 Patient Monitor
http://slidepdf.com/reader/full/g60-patient-monitor 2/2
Eschmann Critical Care15 Peter RoadLancing Business Park
LancingWest Sussex
BN15 8TJ T +44 (0)1903 875700
F +44 (0)1903 875789
Multi-parameter Module(dual-slot)ECG (Philips ECG technology):
Lead type: 3-lead or 5-lead selectable, optional12-lead
Lead selection:
3-lead: I, II, III
5-lead: I, II, III, aVR, aVL, aVF, V 12-lead: I, II, III, aVR, aVL, aVF, V1, V2,
V3, V4, V5, V6
HR measurement range:
Adult/Pediatric: 15 bpm - 300 bpm
Neonate: 15 bpm - 350 bpm
Accuracy: ±1 bpm or ±1 %, whichever is greater
ST measurement range: -2.5 mV - +2.5 mV
Accuracy: ±0.05 mV or ±5 %, whichever
is greater
Arrhythmia: 21 calls
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s,50 mm/s
Gain selection: x 1/4, x 1/2, x 1, x 2, x 4, Auto
Pacemaker detection: Yes
Protection: Against electrosurgical interference
and debrillation.
ECG analog output
Non-Invasive Blood Pressure (NIBP)
Method: Automatic oscillometric
Parameters: SYS/DIA/MAP/Pulse Rate
Operating mode: Manual/Auto/STAT
Auto measure intervals:1-10, 15, 30, 60, 90, 120, 180, 240, 480 minutes
Units: mmHg/kPa
Cuff pressure range:
Adult/Pediatric: 0 - 300 mmHg (0 kPa - 40.0 kPa)Neonate: 0 - 150 mmHg (0 kPa - 20.0 kPa)
Measurement and alarm range:
SYS: Adult /Pediatric: 30 - 255 mmHg (4.0 kPa - 33.9 kPa)
Neonate: 30 - 135 mmHg (4.0 kPa - 18.0 kPa)DIA: Adult/Pediatric: 10 - 220 mmHg (1.3 kPa - 29.3 kPa)
Neonat e: 10 - 110 mmHg (1.3 kPa - 14.7 kPa)
Accuracy: Max. Mean Error: ±5 mmHg (±0.7 kPa)
Max. Std. Deviation: 8 mmHg (1.1 kPa)
PR measurement range: 40 bpm - 240 bmp
Accuracy: ± 2 bpm or ±2 %, whichever is greater
Over-pressure protection: Yes
SpO2(Philips SpO
2 technology)
Measurement range: 0 - 100 %
Accuracy: 70 - 100 %, depends on sensor 0 - 69 %, unspecied
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s,50 mm/s
PR measurement range: 30 - 300 bpm
Accuracy: ±1 bpm or ±2 %, whichever is greater
Respiration (RESP)
Measurement method: Thoracic impedance
Measurement range: Adult: 0 - 120 rpm Pediatric: 0 - 150 rpm
Neonate: 0 - 170 rpm
Accuracy: ±1 rpm in the range of 0 - 70 rpm
±2 rpm in the range of 71 - 120 rpm
±3 rpm in the range of 121 - 170 rpm
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
Gain selection: x 1/2, x 1, x 2
Lead selection: RA - LA, RA - LL, LA - RL, LL - RL
Apnea alarm: Yes, 10 - 60 s
Temperature (TEMP, 2-channel)
Measurement range: 0°C - 50°C (32°F - 122°F)
Resolution: 0.1°C (0.2°F)Accuracy: ±0.1°C (±0.2°F)
Units: °C/°F
IBP (2-channel, optional)
Parameters: SYS/DIA/MAP/Pulse Rate
Measurement range: -50 - 400 mmHg (-6.6 kPa - 53.2 kPa)
Accuracy: ±4 mmHg (±0.53 kPa) or ±4 % ofreading, whichever is greater
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s,50 mm/s
Resolution: 1 mmHg (0.13 kPa)
Units: mmHg/kPa
Transducer sensitivity: 5 uV/V/mmHg
Optional Modules
etCO2 Module (single-slot)
Method: Microstream, infrared absorption
Parameters: RR, etCO2, inCO
2
Measurement range: 0 - 99 mmHg (0 - 13.2 kPa)
Accuracy:
0 - 38 mmHg (0 kPa - 5.06 k Pa): ±2 mmHg (±0.3 kPa)39 - 99 mmHg (5.19 kPa - 13.2 kPa): ±5 % of reading + 0.08 %
for every 1 mmHg above 38 mmHg (5.2 kP a - 13.2 kPa: ±5 %of reading + 0.08 % for every 0.13 kPa above 5.1 kPa)
Resolution: 1 mmHg (0.13 kPa)
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
Respiration rate: 0 - 150 rpm
Accuracy: ± 1 rpm in the range of 0 - 70 rpm ± 2 rpm in the range of 71-120rpm
± 3 rpm in the range of 121 -150 rpm
Units: mmHg/kPa
Dual IBP Module (single-slot)
Parameters: SYS/DIA/MAP/Pulse Rate
Measurement range: -50 - 400 mmHg
(-6.6 kPa - 53.2 kPa)
Accuracy: ±4 mmHg (±0.53 kPa) or ±4 % of
reading, whichever is greater
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s,
50 mm/s
Resolution: 1 mmHg (0.13 kPa)
Units: mmHg/kPa
Transducer sensitivity: 5 uV/V/mmHg
Cardiac Output Module (single-slot)
Measurement method: Right heart thermodilution
Measurement range: 0.1 l/min – 20.0 l/min
Accuracy: ±0.2 l/min or ±10 %, whichever
is greater
Blood temperature range: 27°C - 43°C (80.6°F - 109.4°F)
Accuracy: ±0.1°C
Injection Temperature: 0°C - 27°C (32°F - 80.6°F)
Units: °C/°F
Multi-gas Module (triple-slot)
(Manual Agent ID or Auto Agent ID with O2)
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s,
50 mm/s
O2 measurement range: 0 Vol.% - 100 Vol.%
Accuracy: 0 - 40: ± 1 Vol.% 40 - 60: ± 2 Vol.%
60 - 80: ± 3 Vol.% 80 - 100: ± 4 Vol.%
N2O measurement range: 0 Vol.% - 100 Vol.%Accuracy: 0 - 20: ± 2 Vol.%
20 - 100: ± 3 Vol.%
CO2 measurement range: 0 % - 10 % (0 mmHg - 100 mmHg)
Accuracy: 0 - 1: ± 0.1 %
1 - 5: ± 0.2 % 5 - 7: ± 0.3 %
7 - 10: ± 0.5 % > 10: unspecied
Enurane / Isourane/ Halothane measurement range:
0 Vol.% - 5 Vol.%
Accuracy: 0 - 1: ± 0.15 %
1 - 5: ± 0.2 % > 10: unspecied
Sevourane measurement range:
0 Vol.% - 8 Vol.%
Accuracy: 0 - 1: ± 0.15 % 1 - 5: ± 0.2 %
5 - 8: ± 0.4 % > 8: unspecied
Desurane measurement range: 0 Vol.% - 18 Vol.%
Accuracy: 0 - 1: ± 0.15 %
1 - 5: ± 0.2 % 5 - 10: ± 0.4 %
10 - 15: ± 0.6 % 15 - 18: ± 1%
> 18: unspecied
Flexible Module Server (optional)
8 module slots
1.1m connection cable to monitor
Recorder (optional)
Type: Built-in thermal recorder, 3 channels
Print mode: Real-time recording, timed recording,
alarm-activated recording
Print speed: Auto, 12.5 mm/s, 25 mm/s, 50 mm/s
Display Type: Color TFT LCD
Size: 12.1”
Resolution: 800 x 600 pixels
Channels: Max. 8 channels (14 waveform channels
with 12-lead ECG displayed)
Power Supply
AC power input : 100 V - 240 VAC, 50/60 Hz
Battery (optional): Li-Ion battery, ≥2 hours of continuousmonitoring (with ECG, SpO
2
measurement and NIBP measured every15 minutes)
Weight & Dim ensio ns:
Main unit net weight: Approx. 7 kg (with Multi-parameterModule, Recorder, without battery)
Main unit dimensions: 334 mm (W) x 175 mm (D) x
296 mm (H)
FMS net weight: Approx. 2 kg (without modules)
FMS dimensions: 437 mm (W) x 138 mm (D) x134 mm (H)
Safety Approval & Quality System
Safety standard: IEC 60601-1
Quality system: ISO 9001 & ISO 13485 certiedCE marking according to the Council Directive 93/42/EEC
Data Review and Storage:
1600 sets trend table1200-hour trend data of all par ameters (with Data Manager
function)120-minute full disclosure ECG 1 waveform review (with Data
Manager function)200 sets alarm events
200 sets arrhythmia events
External Interface (standard)
Digital video output, FMS interface, Nurse Call, LAN, USB
Specifcations subject to change without notice
Distributor:
Shenzhen Goldway Industrial Inc.No. 2 Tiangong Road, Nanshan District, Shenzhen,P.R. China 518057
Tel: + 86 - 755 - 26980999 Fax: + 86 - 755 - 26980222E-mail: goldwaymarketingsupport@philips.comwww.goldwayhealthcare.com
After-sale service telephone: + 86 - 755 - 86278308
0123
P/N: 452296281501
To order call 01903 875 700www.eschmanncriticalcare.co.uk