ftd automation instruments ltd · fh series digitalized intelligent pressure/ differential...
Post on 26-Jan-2019
218 Views
Preview:
TRANSCRIPT
FH Capacitance Pressure Transmitter General Introduction.............................................................2 Overview...................................................................................................................................2 Features .....................................................................................................................................3 Working Principle .....................................................................................................................3 Function Parameters..................................................................................................................3 Technical Data...........................................................................................................................4 Dimensions ...............................................................................................................................5 Installation and Process Connection .........................................................................................6 Products Selection Codes..........................................................................................................7 Integral Structure.............................................................................................................
FHGP Gauge Pressure Transmitter ............................................................................................... 10Model Selection ......................................................................................................................10
FHAP Absolute Pressure Transmitter .............................................................................................12Model Selection ......................................................................................................................12
FHDP Differential Pressure Transmitter .........................................................................................14Model Selection ......................................................................................................................14
FHDR Low Differential Pressure Transmitter ................................................................................16 Model Selection ......................................................................................................................16
FHHP High Static Differential Pressure Transmitter ......................................................................18 Model Selection ......................................................................................................................18
FHSP Negative Pressure Transmitter..............................................................................................20 Model Selection ......................................................................................................................20
FHLT Type Level Transmitter.........................................................................................................22 Flange Specification................................................................................................................22 Model Selection ......................................................................................................................23
FHDP/GP Differential Pressure/Pressure Transmitter with Remote Diaphragm seals ...................25 Measuring Range ....................................................................................................................25 Effect Factors ..........................................................................................................................25 Structure Material ...................................................................................................................26 Product selection .....................................................................................................................26 Diaphragm seal types ..............................................................................................................27 PFW Pancake Remote Seal .....................................................................................................28 EFW Extended Flange Seal ....................................................................................................29 RFW Flange Remote Seal .......................................................................................................31RTW Threaded Remote Seal...................................................................................................33 SCW Sanitary tri-clamp seal ...................................................................................................34Capillary Selection code .........................................................................................................34 Remote Seal Fill Liquid Characteristic ...................................................................................34
1
CONTENTS
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FH Capacitance Pressure Transmitter General Introduction
Overview
FH Series Digital Intelligent Pressure/Differential Pressure Transmitter is a multipurpose digitalized intelligent instrument developed by FTD Automation Instruments., including capacitance pressure /differential pressure transmitter and direct-coupled pressure/fluid level transmitter. It is made on the basis of the mature and dependable sensing technology, combining the advanced single-chip computer technology and sensor digital exchange technology.
16-bit single chip is adopted as its core element, with its powerful function and high-speed calculation capacity ensuring the excellent quality of the transmitter. The whole design frame focuses on its dependability, stability and high precision and intelligentization, meeting the growing demand in on-site industrial use. To get this goal, digitalized signal processing technology is used in the software to ensure its disturbance capacity and zero point stability. Meanwhile, it has the Zero Stability Capacity (ZSC) and Temperature Supplementing Capacity (TSC).
The powerful interface functions guarantees an excellent interactivity with no need of manual operator. Its digitalized meter head can display 3 physical parameters including pressure, temperature and current, and 0-100% analogue indications. Keystroke operation can finish the basic settings of zero transfer, range setting, damping setting under the circumstance of no standard pressure, greatly convenient for the on-site debugging.
FH series digitalized Intelligent Pressure/ Differential Pressure Transmitter has the optional HART module. After the transmitter is added the HART module, it has HART communication capacity, with the conventional operation being controlled with the general manual operator. The special communication equipment and soft- ware provided by our company can operate the marking and temperature supplementation actions.
2
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FH series digitalized Intelligent Pressure/ Differential Pressure Transmitter can be widely sued in the sectors such as petroleum, chemical, iron & steel, power supply, light industry and environmental protection, capable of realizing the measurement of various pressures, differential pressures, flows and fluids, adaptable for all kinds of harsh and hazardous environment and corrosive agents.
Features
High accuracy No mechanical and movable parts, little maintenance work Span and zero continuous and adjustable from outside Good stability Positive shift amount to 500%; Negative shift 600% Two-wire system 4~20mA DC Damping adjustable, overpressure protection Solid components, patch-type printed circuit board Explosion-proof structure, all-day use Unified structure, strong interchangeability of parts Miniaturization(total height 166mm) Diaphragm materials of contacting mediums option (316L, TAN, HAS-C, MONEL, etc.) smart HART protocol
Working Principle
Pressure or differential pressure will cause some changes in the sensor resistance value and the output value of bridge voltage. Through A/D conversion, it will change into the digital signal which is sent to the microprocessor for calculation; then a current control signal will be output to the current control circuit, converted into analogue 4-20mA current output. Meanwhile, the microprocessor is responsible for the interactive and other actions (display and setting).
Function Parameters
Service: Liquid, gas and steam Measuring range : 0~0.06 kPa to 0~40Mpa Output signal : 4~20mA DC (four-wire 220V AC
power supply, 0~10mA DC output options) Power supply : 12~45V DC, generally 24V DC. Loading characteristic: relation equation of loading
3
FTD Automation Instruments LTD http://www.ftdinstruments.com/
impedance RL and power voltage Vs: RL <= 50(Vs-12) (see right figure for load characteristic)
Indicator: pointer-type linearity indication 0 ~ 100% scales or LCD indicator, LED indicator. Explosion proof : a. Explosion isolation d II BT4 ; b. Intrinsically safe ia II CT6 Positive and negative shifts :
After positive and negative shifts of zero point, absolute values of upper-and-lower-limit values of span and measuring range should not exceed 100% of upper limit of measuring range.( smart type : turn down ratio 15:1) ; Maximum positive shift is 500% of minimum adjusting span; Maximum negative shift is 600% of minimum adjusting span.
Temperature range: Amplifier operation temperature range: -29 ~ +93°CMeasuring component of fill silicone oil: -40 ~ +104°CFlange type transmitter fill hi-temperature silicone oil: -20 ~ +315°Cnormal silicone oil: -40 ~ +149°C
Static pressure : 1,4, 10, 25, 32Mpa Humidity : relative humidity 0~100%RH Volume absorption : < 0.16cm3 Damping (phase step response) : When filling silicone oil, generally between 0.2s and1.67s,
continuous and adjustable
Technical Data
(Under following condition: no shift, in standard operation conditions, fill silicone oil, 316 SS diaphragm)
Accuracy: +/-0.075%,+/-0.1%,+/-0.25%,+/-0.5% Dead zone: no (<=0.1%) Stability: within 6 months not beyond absolute value of basic error of maximum span Vibration effect: on a random ax upward, at vibration frequency of 200 Hz, error +/-5%/g of
upper limit of measuring range. Power effect: < 0.005%/V of output span Loading effect: no effect from loading at stable power Effect of installation position: Max 0.24kPa of zero error but adjustable, no effect on span
Others Diaphragm: 316 SS, Hastelloy C -276, Monel or Tantalum Exhaust/vent Valve: 316 SS, Hastelloy C or Monel Flange and Connector: 316 SS, Hastelloy or Monel “O” ring: acrylotrile-butadiene rubber, fluorine rubber Fill liquid: silicone oil or inert oil Blot: 316 SS Electronic Body Material: low copper-aluminum alloy Process connection:
Flange NPT 1/4, center distance 54mm;
4
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Process connector NPT 1/2 or M20 ×1.5 male round-cone surfaces sealed, when carrying connector the center distance 50.8, 54, 57.2mm (NPT taper thread accords with GB/T12716-91)
Electrical Connection: G 1/2" Weight: 4.5 kg (standard type)
Dimensions
Size of M Table1-1 *Type 1200 1300 1400 1500 1600 1700 1800 1900 1000 2300
Size(mm) 54 55.6 57.2 58.4 59.2 54 *Type 2400 2500 2600 2700 2800 5600 6600 7600 8600 9600
Size(mm) 54 55.6 57.2 55.6 *Type 5700 6700 7700 8700 9700 6800 7800 8800
M
Size(mm) 55.6 57.2 Note: *Type: see the selection codes for detailed information of types
5
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Installation and Process Connection
Normal Three installation types: Process Connection Types:
Bent bracket for pipe mounting order code B1 Waist shaped flange order code G1
Bent bracket for plate mounting order code B2 Welding pipe adapter order code G2
Flat bracket for pipe mounting order code B3 Integral 3-valve manifold order code G3
6
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Products Selection Codes
Table1-2Code Description FH FTD Automation Instruments
Code Description 0123456789
Negative pressure Gauge pressure(for range 1,2,the differential pressure static pressure is 0.4Mpa) Absolute pressure Differential pressure static pressure 2.5 MPa Differential pressure static pressure 4MPa Differential pressure static pressure 6.4MPa Differential pressure static pressure 16 MPa Differential pressure static pressure 25MPa Differential pressure static pressure32 MPa Differential pressure static pressure 40MPa Code Measuring range
1234567890
0-0.06~0.3kPa 0-0.25~1.5kPa 0-1.2~7.2kPa 0-6~36kPa 0-30~180kPa 0-160~1000kPa 0-400~2500kPa 0-1600~10000kPa 0-4000~25000kPa 0-7000~40000kPa Code Type1
012345
Standard type Single flush flange Double flush flange Single extended flange Double extended flanges One-flush & one-extended flange Code Type 2
01
Standard type with 4-20mA Smart type with HART Protocol
Accessory and Material Selection codes: Table1-3
Code Output L Linearity Output S Square Root Output
Code Mounting Bracket
7
FTD Automation Instruments LTD http://www.ftdinstruments.com/
B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G3 Integral 3-valve manifold G4 Integral 2-valve manifold G5 Integral 5-valve manifold G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
Structure material Selection codes Flange connector Drain/vent valve Isolation diaphragm
F12 Carbon steel 316 L 316 L F13 Carbon steel Hastelloy C Hastelloy C F14 Carbon steel Monel Monel F15 Carbon steel 316 L Titanium F22 316 L 316 L 316 L F23 316 L 316 L Hastelloy C F24 316 L 316 L Monel F25 316 L 316 L Titanium F26 316 L 316 L Hastelloy B F33 Hastelloy C Hastelloy C Hastelloy C F35 Hastelloy C Hastelloy C Titanium F44 Monel Monel Monel
Standard Type
F47 Monel Monel 3YC25
Remarks: ①F22 is standard configuration
②Please indicate process connection when ordering. Factory default is NPT1/4 (F)
8
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Integral Structure
Table1-401 Cover removal 02 O-ring 03 Wire terminal cover 04 Circuit board Mounting bolts 05 Thunder proof wiring circuit board 06 Name plate 07 Housing body 08 Meter head 09 Meter head mounting bolts 10 Meter head cover 11 Drain/vent valve 12 Temp;ate 13 Bolts M10 14 Cover lock bolt 15 Sensor 16 O-ring 17 O-ring 18 Position code plate 19 Zero alignment plate 20 Housing body lockup bolt 21 Parallel wires 22 Circuit board 23 Nut M10 24 Integral 3-valve manifold 25 Welded connector (optional) 26 Waist-shaped flange
9
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHGP Gauge Pressure Transmitter
FHGP type (smart) gauge pressure transmitter has high over pressure strength and good stability. Input span: 0~0.25kPa, 0~10Mpa, 0~40Mpa. Service medium: liquid, gas and steam Overpressure limit:
0~6Mpa over pressure: 0 (absolute pressure) ~14Mpa 0~20Mpa over pressure: 0 (absolute pressure) ~32Mpa 0~40Mpa over pressure: 0 (absolute pressure) ~52Mpa
Flange can afford 60MPa pressure.
Model Selection
Table2-1A S Code Measuring range
Analogue
Smart
FHGP-1200 FHGP-1300 FHGP-1400 FHGP-1500 FHGP-1600 FHGP-1700 FHGP-1800 FHGP-1900 FHGP-1000
0-0.25~1.5kPa 0-1.2~7.2kPa 0-6~36kPa 0-30~180kPa 0-160~1000kPa 0-400~2500kPa 0-1600~10000kPa 0-4000~25000kPa 0-7000~40000kPa
Structure material Code Flange
connector Exhaust/vent
valve Isolation
Diaphragm Fill liquid
F12 CS Cd-plating 316L SS 316L SS F13 CS Cd-plating Hastelloy C Hastelloy C F14 CS Cd-plating Monel Monel F15 CS Cd-plating 316L SS Tantalum
*F22 316L SS 316L SS 316L SS F23 316L SS 316L SS Hastelloy C F24 316L SS 316LSS Monel F25 316L SS 316L SS Tantalum F33 Hastelloy C Hastelloy C Hastelloy C F35 Hastelloy C Hastelloy C Tantalum F44 Monel Monel Monel
Silicone oil
Code Display M1 Linearity indicator 0-100% scale mark M2 LCD Display
10
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Optional components Table2-2
Code Mounting Bracket B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
Remarks: ① Factory span should be specified when ordering, if not specified, at the highest rated span
output, ② Structure material F22 is standard equipment.
11
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHAP Absolute Pressure Transmitter
FHAP type (smart) absolute pressure transmitter can realize absolute measurement of gas; distill tower, evaporator and crystallization, etc.
Service medium: liquid, gas and vapor Overpressure limit: 14MPa (absolute pressure), pressure transmitter not
be damaged, Flange can bear 60MPa pressure.
Model Selection
Table3-1A S Code Measuring range
Analogue
Smart
FHAP-2400 FHAP-2500 FHAP-2600 FHAP-2700 FHAP-2800
0-6~40kPa 0-40~250kPa 0-0.16~1MPa 0-0.4~2.5MPa 0-1.6~10MPa
Structure material Code Flange
connector Exhaust/vent
valve Isolation
Diaphragm Fill Liquid
F12 CS Cd-plating 316L SS 316LSS F13 CS Cd-plating Hastelloy C Hastelloy C F14 CS Cd-plating Monel Monel F15 CS Cd-plating 316L SS Tantalum F22 316L SS 316L SS 316L SS F23 316L SS 316L SS Hastelloy C F24 316L SS 316L SS Monel F25 316L SS 316L SS Tantalum F33 Hastelloy C Hastelloy C Hastelloy C F35 Hastelloy C Hastelloy C Tantalum
F44 Monel Monel Monel
Silicone oil
Code Display M1 Linearity indicator 0-100% scale mark M2 LCD Display
12
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Optional components Table3-2
Code Mounting Bracket B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
Remarks: ③ Factory span should be specified when ordering, if not specified, at the highest rated span
output, ④ Structure material F22 is standard equipment.
13
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHDP Differential Pressure Transmitter
Using differential capacitance as detecting principle to constitute capacitance type differential pressure transmitter, inputting pressure is 0~1.2kPa to 0~10MPa, etc. Service medium: liquid, gas and vapor. Overpressure limit: Max 6MPa ,pressure on either side of the transmitter. The transmitter is not damaged. The transmitter’s operation static pressure is detailed in the models and specifications sheet.
Model Selection
Table4-1A S Code Measuring range Operation pressure(MPa)
Analogue
Smart
FHDP-3300 FHDP-5300 FHDP-5400 FHDP-5500 FHDP-6400 FHDP-6500 FHDP-9600 FHDP-9700 FHDP-8800
0-1.2~7.2kPa 0-1.2~7.2kPa
0-6~36kPa 0-30~180kPa 0-6~36kPa
0-30~180kPa 0-160~1000kPa 0-400~2500kPa
0-1600~10000kPa
2.56.46.46.41616404032
Structure material Code Flange
connector Exhaust/vent
valve Isolation
Diaphragm Fill Liquid
F12 CS Cd-plating 316L SS 316L SS F13 CS Cd-plating Hastelloy C Hastelloy C F14 CS Cd-plating Monel Monel F15 CS Cd-plating 316L SS Tantalum
*F22 316L SS 316L SS 316L SS F23 316L SS 316L SS Hastelloy C F24 316L SS 316L SS Monel F25 316L SS 316L SS Tantalum F33 Hastelloy C Hastelloy C Hastelloy C F35 Hastelloy C Hastelloy C Tantalum F44 Monel Monel Monel
Silicone oil
Code Display M1 Linearity indicator 0-100% scale mark M2 LCD Display
14
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Code Output
L Linearity Output S Square root Output
Optional components Table4-2
Code Mounting Bracket B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G3 Integral 3-valve manifold G4 Integral 2-valve manifold G5 Integral 5-valve manifold G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
Remarks: ① Factory span should be specified when ordering, if not specified, at the highest rated span
output, ② *Structure material F22 is standard equipment.
15
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHDR Low Differential Pressure Transmitter
Using differential capacitance as detecting principle to constitute low differential pressure capacitance type transmitter, inputting 0-0.06~1.5kPa pressure, outputting 4-20 mA DC analogue signal. Service medium: liquid, gas and vapor. Overpressure limit: Max 6MPa (absolute pressure) pressure on
either side of transmitter. Transmitter is not damaged. Flange can afford 60Mpa of pressure.
Model Selection
Table5-1A S Code Measuring range Working pressure (MPa)
Analogue
Smart
FHDR-1100 FHDR-1200 FHDR-3200
0-0.06~0.3kPa 0-0.25~1.5kPa 0-0.25~1.5kPa
0.40.42.5
Structure material Code Flange
connector Exhaust/vent
valve Isolation
Diaphragm Fill Liquid
F12 CS Cd-plating 316L SS 316L SS F13 CS Cd-plating Hastelloy C Hastelloy C F14 CS Cd-plating Monel Monel F15 CS Cd-plating 316L SS Tantalum F22 316L SS 316L SS 316L SS F23 316L SS 316L SS HC F24 316LSS 316L SS Monel F25 316L SS 316L SS Tantalum F33 Hastelloy C Hastelloy C Hastelloy C F35 Hastelloy C Hastelloy C Tantalum F44 Monel Monel Monel
Silicone oil
Code Display M1 Linearity indicator 0-100% scale mark M2 LCD Display
Code Output L Linearity Output S Square root Output
16
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Optional components Table5-2
Code Mounting Bracket B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G3 Integral 3-valve manifold G4 Integral 2-valve manifold G5 Integral 5-valve manifold G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
Remarks: ① Factory span should be specified when ordering, if not specified, at the highest rated span
output, ② Structure material F22 is standard equipment.
17
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHHP High Static Differential Pressure Transmitter
FHHP type high static pressure differential pressure transmitter can measure differential pressure under operation pressure of 32MPa.
Model Selection
Table6-1
A S Code Measuring Range Operation Pressure (MPa)
Analogue
Smart
FHHP-7400 FHHP-8400 FHHP-9400 FHHP-7500 FHHP-8500 FHHP-9500
0-6~36kPa 0-6~36kPa 0-6~36kPa 0-30~180kPa 0-30~180kPa 0-30~180kPa
253240253240
Structural Material Code Flange
Adapter Exhaust/vent
Valve Isolation
Diaphragm Liquid
FillF12 CS Plating Cadmium 316LSS 316LSS F13 CS Plating Cadmium Hastelloy C Hastelloy C F14 CS Plating Cadmium Monel Monel F15 CS Plating Cadmium 316LSS Tantalum F22 316L SS 316LSS 316LSS F23 316L SS 316L SS Hastelloy C F24 316L SS 316L SS Monel F25 316L SS 316L SS Tantalum F33 Hastelloy C Hastelloy C Hastelloy C F35 Hastelloy C Hastelloy C Tantalum F44 Monel Monel Monel
Silicone oil
Code Display M1 Linear indicator 0-100% scale mark M2 Digital indicator
Code Output L Linearity Output S Square root Output
18
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Optional components Table6-2
Code Mounting Bracket B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G3 Integral 3-valve manifold G4 Integral 2-valve manifold G5 Integral 5-valve manifold G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
Remarks: ① Factory span should be specified when ordering, if not specified, at the highest rated span
output, ② Structure material F22 is standard equipment.
19
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHSP Negative Pressure Transmitter
FHSP type capacitance type negative pressure has high accuracy and wide range of operation temperature. Service medium: liquid, gas or vapor. Overpressure limit: impose 0~14MPa (Absolute pressure)
pressure on either side of transmitter. Transmitter is not damaged. Flange can afford 60 MPa pressure. Normal operation pressure is not more than 3.45kPa (absolute
pressure).
Model Selection
Table7-1A S Code Measuring Range
Analogue
Smart
FHSP-0200 FHSP-0300 FHSP-0400 FHSP-0500
0-0.25~1.5kPa 0-1.2~7.2kPa 0-6~36kPa
0-30~98kPa
Structure material Code Flange
connector Exhaust/vent
valve Isolation
Diaphragm Fill Liquid
F12 CS Plating Cadmium 316LSS 316LSS F13 CS Plating Cadmium Hastelloy C Hastelloy C F14 CS Plating Cadmium Monel Monel F15 CS Plating Cadmium 316LSS Tantalum F22 316L SS 316L SS 316LSS F23 316L SS 316L SS Hastelloy C F24 316L SS 316L SS Monel F25 316L SS 316L SS Tantalum F33 Hastelloy C Hastelloy C Hastelloy C F35 Hastelloy C Hastelloy C Tantalum F44 Monel Monel Monel
Silicone oil
Code Display M1 Linear indicator 0-100% scale mark M2 Digital indicator
20
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Optional components Table7-2
Code Mounting Bracket B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
Remarks: ① Factory span should be specified when ordering, if not specified, at the highest rated span
output, ② Structure material F22 is standard equipment.
21
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHLT Type Level Transmitter
FHLT (smart) flange type level transmitter can carry on accurate measurement of level and density for all kinds of containers. Flush flange and extended flange available, 3" or 4", 1501b or 3001b flange, custom-made flange option.
Flange Specification
22
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHLT Flange type level Transmitter Dimensions Table8-1
Flange size Bolt Hole No
. Flange size OD
D(mm)
ID
B(mm)
Seal face
C(mm)
Thickness
A(mm)
No.
n
Diameter
d(mm)
Bolt Circle
D1(mm)
Rated
Pressure
Mpa
1 2”150LB 152 48 92 18 4 19 121 2.5 2 2”300LB 165 48 92 21 4 19 127 5 3 3”150LB 190 66 127 22 4 19 152 2.5 4 3”300LB 210 66 127 27 8 22 168 5 5 4”150LB 229 89 157 30 8 19 190 2.5 6 4”300LB 255 89 157 32 8 22 200 5 7 DN25(PN
2.5/4.0) 165 48 92 21 4 22 125 4
8 DN80(PN2.5/4.0)
215 66 127 24 8 160 4
9 DN100(PN2.5/4.0)
235 89 157 28 8 22 190 4
Flange sealing gasket Dimension
Flange sealing gasket material can be selected according to the measured medium, there are asbestos rubber, acrylonitrile-butadiene rubber, fluororubber, nylon,PTFE to be selected.
Model Selection
Table8-2 A S Code
(Single Flush Flange) Measuring range Code
(Single Extended flange) Measuring range
Analogue
Smart
FHLT-3310 FHLT-4410 FHLT-4510 FHLT-4610 FHLT-4710
0-1.2-7.2kPa 0-6-36kPa
0-30-180kPa 0-160-1000kPa 0-400-2500kPa
FHLT-3330 FHLT-4430 FHLT-4530 FHLT-4630 FHLT-4730
0-1.2-7.2kPa 0-6-36kPa
0-30-180kPa 0-160-1000kPa 0-400-2500kPa
*Code Flange Specification Code Extended Length
23
FTD Automation Instruments LTD http://www.ftdinstruments.com/
ABCDEFGHIJ
3 ” 1501b 4 ” 1510b 3 ” 3001b 4 ” 3001b 2” 1501b 1” 1501b
DN50 1.6Mpa/4Mpa DN80 1.6Mpa/4Mpa
DN100 1.6Mpa Special design
A0 B1C2D3
0 mm 50 mm
100 mm 150 mm
Code Display M1 Linearity indicator 0-100% scale mark M2 Digital indicator
Code Diaphragm material of high side flange K1 316L K2 Hastelloy C 276 K3 Tantalum (Only for flush flange)
Optional components Table8-3
Code Mounting Bracket B1 Bend bracket for pipe mounting (2” pipe) B2 Bend bracket for plate mounting B3 Flat bracket for pipe mounting (2” pipe)
Code Position of exhaust/vent valve D1 Side exhaust/vent valve of flange on top D2 Side exhaust/vent valve of flange at bottom
Code Process Connection G0 NPT1/4 (F)
G1 NPT 1/2(F) Waist type flange G2 NPT1/2-M20*1.5-Φ14 Welding pipe connector G6 M20*1.5(M) T-shape connector G7 M20*1.5(M) -Φ14 Welding pipe connector
Code Process flange O-Ring material O1 Process flange O-Ring material: Nitrile rubber O2 Process flange O-Ring material: PTFE rubber
Code Hazardous Area d Explosion separation type Exds II BT5 i Intrinsically safe Exib II CT5
*Flange Selection Code Example: For example, 3”, 150LB Flange with 50mm extended length, the selection codes should be BB1
24
FTD Automation Instruments LTD http://www.ftdinstruments.com/
FHDP/GP Differential Pressure/Pressure Transmitter with Remote
Diaphragm seals
FHDP/GP Differential Pressure/Pressure Transmitter with Remote Diaphragm seals provides a kind of reliable measuring way to avoid the measured medium from directly contacting with seal diaphragm of the transmitter. Transmitters with Remote Diaphragm seals are suitable for the following operation conditions: Mediums with high temperature should be isolated with transmitter. Measured mediums have corrosion to transmitters. Suspending liquid or mediums with high viscosity Measured mediums solidize or crystalize due to change of environment or technological
process temperature. Strict purification of measuring head is needed for replacing measured mediums Measuring head must be kept clean and sanitary. Pressure measurement of sealed container
Measuring Range
1.Remote double flush flanges
FHDP-4420 0-6-36kPa FHDP-4520 0-30-180kPa FHDP-4620 0-160-1000kPa FHDP-4720 0-400-2500kPa
2.Remote single flush flange
FHDP-1410 0-6-36kPa FHDP-1510 0-30-180kPa FHDP-1610 0-160-1000kPa FHDP-1710 0-400-2500kPa FHDP-1810 0-1600-10000kPa
3. Remote double extended flange type
FHDP-4340 0-1.2-7.2kPa FHDP-4440 0-6-36kPa FHDP-4540 0-30-180kPa FHDP-4640 0-160-1000kPa FHDP-4740 0-400-2500kPa
4. Remote flush & extended flanges
FHDP-4350 0-1.2-7.2kPa FHDP-4450 0-6-36kPa FHDP-4550 0-30-180kPa FHDP-4650 0-160-1000kPa FHDP-4750 0-400-2500kPa
5.Remote extended flange type
FHDP-1330 0-1.2-7.2kPa FHDP-1430 0-6-36kPa FHDP-1530 0-30-180kPa FHDP-1630 0-160-1000kPa FHDP-1730 0-400-2500kPa FHDP-1830 0-1600-10000kPa
Effect Factors
1. Temperature Effect
25
FTD Automation Instruments LTD http://www.ftdinstruments.com/
Remote diaphragm is normally equipped with 1.5 m capillary; PFW Pancake seal and SCW Sanitary tri-clamp seal
The error from temperature effect on PFW Pancake seal and SCW Sanitary tri-clamp seal is less than 0.62Kpa/55℃. The error increases 0.2Kpa when the capillary increases per 1.5 meters.
RTW Threaded remote seal and RFW flange remote seal The error from temperature effect on RTW Threaded remote seal and RFW flange remote seal is less than 1.99Kpa/55℃. The error increases 0.62Kpa when the capillary increases per 1.5 meters. 2. Power supply Effect Less than 0.005 % of output range 3. Load Effect No load effect when the power supply is high than 12V DC. 4. Installation Position Effect Max 250Pa effect but can be adjusted, no effect on the measuring range.
Structure Material
Remote measuring head, capillary tube and fill liquid refer to the selection code Diaphragm and exhaust/vent valve: 316 stainless steel Remote transmission side flange: carbon-steel plating cadmium or 316 stainless steel Flange or blot: carbon-steel plating cadmium Fill liquid: silicone oil or inert liquid O-ring: fluorine rubber Electrical shell: low copper-aluminum alloy
Product selection
Table9-1 Code Description FH FTD Automation Instruments
Code Description 13456789
Gauge pressure(for range 1,2,the differential pressure static pressure is 0.4Mpa) Differential pressure static pressure 2.5 MPa Differential pressure static pressure 4MPa Differential pressure static pressure 6.4MPa Differential pressure static pressure 16 MPa Differential pressure static pressure 25MPa Differential pressure static pressure32 MPa Differential pressure static pressure 40MPa
Code Measuring range
26
FTD Automation Instruments LTD http://www.ftdinstruments.com/
1234567890
0-0.06~0.3kPa 0-0.25~1.5kPa 0-1.2~7.2kPa 0-6~36kPa 0-30~180kPa 0-160~1000kPa 0-400~2500kPa 0-1600~10000kPa 0-4000~25000kPa 0-7000~40000kPa
Code Type 1
12345
Single flush flange Double flush flange Single extended flange Double extended flanges One-flush & one-extended flange Code Type 2 * PFWEFWRFWRTW SCW
Pancake seal remote seal Extended flange seal Flange remote seal Threaded Remote Seal Sanitary tri-clamp seal
Code Mounting Bracket B1B2B3
Bend bracket for pipe mounting (2” pipe) Bend bracket for plate mounting Flat bracket for pipe mounting (2” pipe) Code Output
L S
Linearity Output Square root Output (only for DP)
Code Hazardous Area Di
Explosion separation type Exds II BT5 Intrinsically safe Exib II CT5 Code Capillary CAP Refer to Table 9-9
Type 2 * Refer to Table9-2, 9-3, 9-4, 9-5, 9-6, 9-7, 9-8
Diaphragm seal types
PFW Pancake seal remote seal EFW Extended flange seal RFW Flange remote seal RTW Threaded Remote Seal SCW Sanitary tri-clamp seal
27
FTD Automation Instruments LTD http://www.ftdinstruments.com/
PFW Pancake Remote Seal
Selection Code
Table9-2 PFW Pancake Seal Remote seal
Code Type ACGH
3 ” 1501b 3 ” 3001b DN50 1.6Mpa/4Mpa DN80 1.6Mpa/4Mpa Code Diaphragm material of high side flange K1 316L K2 Hastelloy C 276 K3 Tantalum
Code Flange material and rated pressure A11 Galvanised Carbon Steel ,Max pressure rating: 150LB A12 Galvanised Carbon Steel ,Max pressure rating: 300LB A31 316 SST, Max pressure rating: 150LB
28
FTD Automation Instruments LTD http://www.ftdinstruments.com/
EFW Extended Flange Seal
Selection Code
Table9-3 EFW Extended Flange Seal
Code Type ABCDEFGHIJ
3 ” 1501b 4 ” 1510b 3 ” 3001b 4 ” 3001b 2” 1501b 1” 1501b DN50 1.6Mpa/4Mpa DN80 1.6Mpa/4Mpa DN100 1.6Mpa Special design Code Diaphragm material of high side flange K1 316L K2 Hastelloy C 276 K3 Tantalum
Code Flange material and rated pressure A11 Galvanised Carbon Steel ,Max pressure rating: 150LB A12 Galvanised Carbon Steel ,Max pressure rating: 300LB A31 316 SST, Max pressure rating: 150LB A32 316 SST, Max pressure rating: 300LB
Code Extended length B1 2” (50mm) C2 4” (100mm) D3 6”(150mm)
29
FTD Automation Instruments LTD http://www.ftdinstruments.com/
PFW Pancake Seal Remote seal Dimensions EFW Extended Flange Seal Dimensions
PFW & EFW Remote seal Flange Dimensions Table9-4
Flange size Bolt Hole
No Flange size OD
D(mm)
ID
B(mm)
Seal face
C(mm)
Thickness
A(mm)
No.
n
Diameter
d(mm)
Bolt Circle
D1(mm)
Rated
Pressure
Mpa
1 2”150LB 152 48 92 18 4 19 121 2.5 2 2”300LB 165 48 92 21 4 19 127 5 3 3”150LB 190 66 127 22 4 19 152 2.5 4 3”300LB 210 66 127 27 8 22 168 5 5 4”150LB 229 89 157 30 8 19 190 2.5 6 4”300LB 255 89 157 32 8 22 200 5 7 DN25(PN
2.5/4.0) 165 48 92 21 4 22 125 4
8 DN80(PN2.5/4.0)
215 66 127 24 8 160 4
9 DN100(PN2.5/4.0)
235 89 157 28 8 22 190 4
30
FTD Automation Instruments LTD http://www.ftdinstruments.com/
RFW Flange Remote Seal
RFW Flange Dimensions Table9-5
Upper Flange Bolt Hole Lower Flange Nominal
Diameter
(inch)
Pressure
(LB/Mpa)
OD
A(mm)
Boss
Dia.C(mm)
Thickness
D(mm)
No.
n
Dia.
D(mm)
Bolt
Circle
B(mm)
Dia.
E(mm)
Dia.
F(mm)
150/2 108 61.4 14.3 4 16 79.4 1300/5 124 66.9 17.2 4 19 89
26.9 66.5
150/2 127 73 17.2 4 16 98.4 1.5300/5 156 73 20.7 4 22 114.5
41.9 78.7
150/2 152 92.1 19.1 4 19 121 2300/5 165 92.1 22.2 8 19 127
52.5 95.2
150/2 190 127 23.8 4 19 152 3300/5 210 127 25.5 8 22 168
79 127
150/2 229 23.8 8 19 190 4300/5 255 31.8 8 22 200
103 157
Selection Code
Table9-6 RFW Flange remote seal
Code Clean Hole 11 With clean hole 12 Without clean hole
Code Diaphragm material of high side flange K1 316L K2 Hastelloy C 276 K3 Tantalum
Code Upper flange material A11 Galvanised Carbon Steel A31 316 SST, Max pressure rating
Code Lower Flange size Max Pres. Lower flange material A21 1” 2.5Mpa 316 SST
31
FTD Automation Instruments LTD http://www.ftdinstruments.com/
B21 1” 2.5Mpa Hastelloy C 276 E21 1” 2.5Mpa Galvanised Carbon Steel A41 1.5” 2.5Mpa 316 SST B41 1.5” 2.5Mpa Hastelloy C 276 E41 1.5” 2.5Mpa Galvanised Carbon Steel A51 2” 2.5Mpa 316 SST B51 2” 2.5Mpa Hastelloy C 276 E51 2” 2.5Mpa Galvanised Carbon Steel A71 3” 2.5Mpa 316 SST B71 3” 2.5Mpa Hastelloy C 276 E71 3” 2.5Mpa Galvanised Carbon Steel A22 1” 5Mpa 316 SST B22 1” 5Mpa Hastelloy C 276 E22 1” 5Mpa Galvanised Carbon Steel A42 1.5” 5Mpa 316 SST B42 1.5” 5Mpa Hastelloy C 276 E42 1.5” 5Mpa Galvanised Carbon Steel A52 2” 5Mpa 316 SST B52 2” 5Mpa Hastelloy C 276 E52 2” 5Mpa Galvanised Carbon Steel A72 3” 5Mpa 316 SST B72 3” 5Mpa Hastelloy C 276 E72 3” 5Mpa Galvanised Carbon Steel
32
FTD Automation Instruments LTD http://www.ftdinstruments.com/
RTW Threaded Remote Seal
RTW Threaded remote seal can bear max 10Mpa working pressure.
RTW Threaded remote seal Selection Code
Table9-7 RTW Threaded remote seal
Code Clean Hole 11 With clean hole 12 Without clean hole
Code Diaphragm material of high side flange K1 316L K2 Hastelloy C 276 K3 Tantalum
Code Upper flange material A11 Galvanised Carbon Steel A31 316 SST, Max pressure rating
Code Lower flange material A21 316 SST Code Process connection 13 NPT1/2
33
FTD Automation Instruments LTD http://www.ftdinstruments.com/
SCW Sanitary tri-clamp seal
DN50, PN40, Dimensions Table9-8
Dimension (mm) dM D H h 40 75 58 35
Material of Sanitary tri-clamp seal: 316 SST
Capillary Selection code
Table9-9 CPA capillary ,304 SST, Dimensionsφ3×1
Code Capillary length (m) 15 1.5 30 3.0 45 4.5 60 6.0 75 7.5
Code Material A Mineral insulated 304 SST B PVC sheath, Mineral insulated 304 SST
Remote Seal Fill Liquid Characteristic
Table9-10 Code Fill Liquid Temp.Range Gravity(g/cm2) Temp. Expansion
FactorViscosity at 25℃
(Mpa·S)D Silicon oil -40~150℃ 0.934 0.00108 <20 S High temp. Silicon oil 5~350℃ 1.07 0.00053 44~55 F Inertia fill liquid -45~205℃ 1.85 0.000864 65
34
FTD Automation Instruments LTD http://www.ftdinstruments.com/