MXTG2-STRA300(1” Regress)
B W SN
Available finishes
AB WH
B W SN
Available finishes
AB WH
MXG2ASTR3.5” MX G2 LED Square Adjustable
FEATURES ■ Multiple architectural trim options ■ High center beam spot up to 24,500 CBCP ■ Dedicated 9° with field changeable 12°, 24°, 36° & 50° optics
LED LIGHT ENGINE ■ 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning
■ >50,000 hours L70 (rated life at 70% output)
ELECTRICAL SYSTEM ■ Multiple dimming drivers available ■ (Non-IC) 120V or 277V input; Power factor >.9 50/60Hz ■ (-IC/-CP) Universal 120V/277V input; Power factor >.9 50/60Hz ■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty.
HOUSING ■ Heavy duty black powder coated 18 gauge steel frame ■ Standard housing accommodates 5/8” ceiling thickness ■ Extended collar options available for ceilings up to 1” or 2” thick, must specify either EC1 or EC2 (EC1/EC2 Not available with Chicago Plenum)
INSTALLATIONHousing types include IC Air-Tight, CCEA (Chicago Plenum), or Non-IC Rated (must specify). Non-IC rated housings must be kept at a minimum of 3” away from insulation. Butterfly brackets are compatible with C-channel, adjustable bar hangers (14”-25”) and EMT. C-channel is recommended for T-bar ceilings. Bar hangers must be ordered separately. Max. ambient temperature: 131°F (55°C).
TRIM SPECIFICATIONAiming with locking 35° vertical and 360° horizontal adjustment with 1/2” regress and 90° turns (90, 180, 270 and 360) with 1” regress for greater visual comfort. See fixture aiming chart on page 2. High quality trims are die-cast using A380 aluminum with durable powder coat available in multiple finishes. Architectural, discrete self flange or painted white flange options available. Trims available in 1” regress for greater visual comfort or 1/2” regress for consistent look throughout space.
EMERGENCY BACKUPRemote test switch included. External battery operates LED load at a minimum of 500 to 850 lumens for 90 minutes, depending on backup wattage selected. See trim multipliers for detailed performance. Servicing requires above ceiling access.(EM not available with Chicago Plenum)
LISTING / WARRANTY ■ 5-Year Intense LED Limited Warranty ■ ETL listed to US and Canadian standards for damp locations ■ (-IC/-CP Only) Air-Tight Certified ASTM E283 ■ (-IC/-CP Only) ETL listed for direct contact w/insulation ■ (-CP Only) CCEA Chicago Plenum ■ ENERGY STAR® Qualified 1
■ Can be used to comply with 2016 Title 24-Part 6 High Efficacy LED Light Source Requirements 2
21
Housing dimensions are on Page 2
3 1/2”
4 1/2”
1”
1/2”
4 1/2”
3 1/2”
0.15” trim thickness
0.15” trim thickness
MXTG2-STRR300(1/2” Regress)
Notes:1. ENERGY STAR® Qualified (White reflectors only;
Excludes: L2, L3, 92 CRI & 9° options)2. Excludes: L2, L3, 82 CRI & 9° options3. EC1/EC2 not available with (-CP) Chicago
Plenum4. L3 available with Non-IC housings only5. Available in 120V only6. Not Available in L37. Not Available in L2 & L38. DMX512 RDM not available in L0 & L19. Access above ceiling required; not available
with (-CP) Chicago Plenum10. Not available in L011. Consult factory for lead times12. 9° Narrow spot not available in L2 & L3
Housing Part Number (Example: MXG2ASTR-ICL1)
Housing Installation Type Ceiling Thickness Wattage Dimming Voltage Options
MXG2ASTR -NC-IC-CP
(Non-IC)(Air-Tight IC)(Chicago Plenum)
blankEC13
EC23
(5/8”)(1”)(2”)
L0L1L2L34
(10W)(16W)(20W)(26W)
blankDELV5
D101ED10V16
ED10V016
LUT7
LUT2DMXR8
(Non-Dimming)(Phase Dimming)(0-10V Dimming 1%)(eldoLED 0-10V 1%)(eldoLED 0-10V 0.1%)(Lutron EcoSystem® 1%)(Lutron 2-Wire® 1%)(DMX512 RDM 0.1%)
blank
27
(Non-IC: 120V-IC/-CP: 120V/277V)(277V Non-IC Only, for -IC/-CP housing options use blank)
I100I200I400-EM79
-EM129, 10
(C-Channel Bar Hangers)(Flat Bar Hangers)(Wood Joist Bar Hangers)(7W Emergency BackupIOTA Part #ILB-CP07-A)(12W Emergency BackupIOTA Part #ILB-CP12-A)
Trim Part Number (Example: MXTG2-STRA300W-SFL13024)
Trim Finish Wattage CCT / CRI Optic
MXTG2-STRA300 (1” Regress)MXTG2-STRR300(1/2” Regress)
B-SFB-SFWW-SFSN-SFSN-SFW11
AB-SFAB-SFW11
WH-SFWH-SFW11
(Black / Self Flanged)(Black / Self Flanged White)(White / Self Flanged)(Satin Nickel / Self Flanged)(Satin Nickel / Self Flanged White)(Antique Bronze / Self Flanged)(Antique Bronze / Self Flanged White)(Wheat / Self Flanged)(Wheat / Self Flanged White)
L0L1L2L34
(10W)(16W)(20W)(26W)
27279303093535941419
(2700K / 82 CRI)(2700K / 92 CRI)(3000K / 82 CRI)(3000K / 92 CRI)(3500K / 82 CRI)(3500K / 92 CRI)(4100K / 82 CRI)(4100K / 92 CRI)
0912
12243650
(9° Narrow Spot)(12° Spot)(24° Narrow Flood)(36° Flood)(50° Wide Flood)
ELECTRICAL DATA
LED Light Engine System Wattage * CCT / CRI Delivered Lumens ** Lumens Per Watt
L0L1L2L3
10W16W20W26W
3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI
900lm1250lm1450lm1800lm
90787369
* System wattage includes driver and LED module consumption.** Delivered lumens will vary depending on trim, CCT, CRI, optic and ceiling thickness
JOB NAME
CATALOG NUMBER
NOTES TYPE
MX ADJUSTABLE L/M-012:19 P-49
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
35°
MXG2ASTR3.5” MX G2 LED Square Adjustable
4 1/4”
5 3/8”
12”
12”7 3/4”
NON-IC & AIR TIGHT IC DIMENSIONS
CCEA CHICAGO PLENUM DIMENSIONS
Ceiling Cut Out: 4 1/8”
5/8” StandardEC1 = 1”EC2 = 2”
12”
12”7 3/4”
4 1/4”
7 1/4”
5/8” StandardEC1 = 1”EC2 = 2”
35°
Ceiling Cut Out: 4 1/8”
ACCESSORIESLuminaire will accommodate (2) accessories, accessory holder required.
INSTALLATION1. Rotate release cap by turning counter clockwise.2. Install accessories into accessory holder and replace accessory holder’s retaining clip.3. Place accessory holder and accessory flush against optic and replace release cap.
OPTICS REPLACEMENT1. Rotate release cap by turning counter clockwise.2. Install accessories into accessory holder and replace accessory holder’s retaining clip.3. Place accessory holder and accessory flush against optic and replace release cap.
Release cap
Accessory holder
Release cap
Accessories
Retainer ring
Accessory holder’s retaining clip
Optic
Module
Accessories
LH47LH47WPFLMB-47PFL1-47PFL2-47PFL4-47
(Accessory Holder, Black)(Accessory Holder, White)(Hex Louver, Black)(Prismatic Spread Lens)(Linear Spread Lens)(Soft Focus Lens)
Optics
IP-OP4712IP-OP4724IP-OP4736IP-OP4750
(12° Spot)(24° Narrow Flood)(36° Flood)(50° Wide Flood)
Plaster Frame Accommodation
Collar Type Standard EC1 EC2
Max Ceiling Thickness Up-to 5/8” Up-to 1” Up-to 2”
Fixture Aiming - Horizontal Adjustment
1” Regress Trims 90° turns 90° turns Full 360°
½” Regress Trims Full 360° Full 360° Full 360°
Plaster Frame Accommodation
Collar Type Standard EC1 EC2
Max Ceiling Thickness Up-to 5/8” Up-to 1” Up-to 2”
Fixture Aiming - Horizontal Adjustment
1” Regress Trims 90° turns 90° turns Full 360°
½” Regress Trims Full 360° Full 360° Full 360°
JOB NAME
CATALOG NUMBER
NOTES TYPE
MX ADJUSTABLE L/M-012:19 P-50
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
Report #: ILL-02222016-01.3 (12) ILL-02222016-02.3 (24) ILL-02222016-03.3 (36) ILL-02222016-04.3 (50)
MXTG2-STRA300WL0
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL
D FC W L D C FC W L D C FC W L
MXTG2-STRA300WL03000K
12° Spot
6’8’
10’12’
33819012284.4
1.31.82.22.7
1.41.82.32.7
6’8’
10’12’
4567
19811874.451
1.982.583.133.82
1.492.1
2.673.19
3’4’5’6’
4679
31719812987.9
1.151.491.892.55
2.422.963.484.24
MXTG2-STRA300WL03000K
24° Narrow Flood
6’8’
10’12’
15184.754.237.6
2.43.24
4.8
2.23
3.74.4
6’8’
10’12’
4566
87.850.632.622.7
3.24.195.226.24
2.643.354.165.03
3’4’5’6’
4578
16993.759.442.2
1.782.53.153.65
3.224.285.366.31
MXTG2-STRA300WL03000K
36° Flood
6’8’
10’12’
61.534.622.115.4
3.95.26.57.8
3.54.75.87
6’8’
10’12’
3456
39.422.114.29.8
4.66.167.679.21
3.635.016.277.48
3’4’5’6’
3567
74.642.227.819.5
2.763.464.335.13
45.346.477.64
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
121584706428107365
3117
6233
9350
12467 10°
80°
70°
60°
50°
40°
30°20°
12° Spot (12)
Watts: 10Lumens: 857 LPW: 86 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
541945211351165213
1380
2761
4141
5522 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 10Lumens: 902 LPW: 90 CCT: 3000K
35°
35°
555
1110
1665
2220 10° 20°
36° Flood (36)
Watts: 10Lumens: 851 LPW: 85 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
221322051313397808
80°
70°
60°
50°
40°
30°
MXTG2-STRA300WL03000K
50° Wide Flood
6’8’
10’12’
23.413.28.45.9
6.28.210.312.4
5.87.89.711.7
6’8’
10’12’
2334
17.59.86.34.4
5.767.769.6811.51
5.327.198.9710.67
3’4’5’6’
3456
33.919.112.28.5
3.464.75.846.99
4.185.56.898.2
221
442
663
884 10° 20°
50° Wide Flood (50)
Watts: 10Lumens: 726 LPW: 73 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
84488277944518048
80°
70°
60°
50°
40°
30°
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
Emergency Multiplier: 7W Emergency (x 0.70)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)
MXTG2-STRA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)
MXTG2-STRR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MX ADJUSTABLE L/M-012:19 P-51
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
Report #: ILL-02222016-01.2 (12) ILL-02222016-02.2 (24) ILL-02222016-03.2 (36) ILL-02222016-04.2 (50)
MXTG2-STRA300WL1
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL
D FC W L D C FC W L D C FC W L
MXTG2-STRA300WL13000K
12° Spot
6’8’
10’12’
473266170118
1.31.82.22.7
1.41.82.32.7
6’8’
10’12’
4567
27716510471.4
1.982.583.133.82
1.492.1
2.673.19
3’4’5’6’
4679
444277180123
1.151.491.892.55
2.422.963.484.24
MXTG2-STRA300WL13000K
24° Narrow Flood
6’8’
10’12’
21111975.952.7
2.43.24
4.8
2.23
3.74.4
6’8’
10’12’
4566
12370.845.731.8
3.24.195.226.24
2.643.354.165.03
3’4’5’6’
4578
23613183.159
1.782.53.153.65
3.224.285.366.31
MXTG2-STRA300WL13000K
36° Flood
6’8’
10’12’
8648.431
21.5
3.95.26.57.8
3.54.75.87
6’8’
10’12’
3456
55.131
19.813.8
4.66.167.679.21
3.635.016.277.48
3’4’5’6’
3567
10459.138.927.3
2.763.464.335.13
45.346.477.64
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
170216589599150517
4363
8727
13090
17454 10°
80°
70°
60°
50°
40°
30°20°
12° Spot (12)
Watts: 15.4Lumens: 1205 LPW: 78 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
758663291892231294
1933
3865
5798
7730 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 15.5Lumens: 1263 LPW: 81 CCT: 3000K
35°
35°
777
1564
2330
3107 10° 20°
36° Flood (36)
Watts: 15.5Lumens: 1191 LPW: 77 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
30983087183855511211
80°
70°
60°
50°
40°
30°
MXTG2-STRA300WL13000K
50° Wide Flood
6’8’
10’12’
32.818.511.88.2
6.28.210.312.4
5.87.89.711.7
6’8’
10’12’
2334
24.513.78.86.1
5.767.769.6811.51
5.327.198.9710.67
3’4’5’6’
3456
47.526.717.111.9
3.464.75.846.99
4.185.56.898.2
309
613
928
1237 10° 20°
50° Wide Flood (50)
Watts: 15.5Lumens: 1017 LPW: 66 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
11811234109162325368
80°
70°
60°
50°
40°
30°
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
EMERGENCY MULTIPLIER: 7W Emergency (x 0.50)12W Emergency (x 0.85)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)
MXTG2-STRA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)
MXTG2-STRR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MX ADJUSTABLE L/M-012:19 P-52
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
Report #: ILL-02222016-01.1 (12) ILL-02222016-02.1 (24) ILL-02222016-03.1 (36) ILL-02222016-04.1 (50)
MXTG2-STRA300WL2
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL
D FC W L D C FC W L D C FC W L
MXTG2-STRA300WL23000K
12° Spot
6’8’
10’12’
554312199138
1.31.82.22.7
1.41.82.32.7
6’8’
10’12’
4567
32419412283.7
1.982.583.133.82
1.492.1
2.673.19
3’4’5’6’
4679
520324211144
1.151.491.892.55
2.422.963.484.24
MXTG2-STRA300WL23000K
24° Narrow Flood
6’8’
10’12’
24713988.961.7
2.43.24
4.8
2.23
3.74.4
6’8’
10’12’
4566
14483
53.537.3
3.24.195.226.24
2.643.354.165.03
3’4’5’6’
4578
27715497.469.1
1.782.53.153.65
3.224.285.366.31
MXTG2-STRA300WL23000K
36° Flood
6’8’
10’12’
10156.736.325.2
3.95.26.57.8
3.54.75.87
6’8’
10’12’
3456
64.536.323.216.1
4.66.167.679.21
3.635.016.277.48
3’4’5’6’
3567
12269.245.632
2.763.464.335.13
45.346.477.64
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
199397718702175598
5111
10223
15334
20446 10°
80°
70°
60°
50°
40°
30°20°
12° Spot (12)
Watts: 20.5Lumens: 1406 LPW: 69 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
888774152216271344
2264
4528
6792
9055 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 20.4Lumens: 1480 LPW: 73 CCT: 3000K
35°
35°
910
1820
2730
3640 10° 20°
36° Flood (36)
Watts: 20.5Lumens: 1395 LPW: 68 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
36293617215365113112
80°
70°
60°
50°
40°
30°
MXTG2-STRA300WL23000K
50° Wide Flood
6’8’
10’12’
38.421.613.89.6
6.28.210.312.4
5.87.89.711.7
6’8’
10’12’
2334
28.716
10.37.2
5.767.769.6811.51
5.327.198.9710.67
3’4’5’6’
3456
55.631.320
13.9
3.464.75.846.99
4.185.56.898.2
362
725
1087
1450 10° 20°
50° Wide Flood (50)
Watts: 20.4Lumens: 1191 LPW: 58 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
13841446127873029679
80°
70°
60°
50°
40°
30°
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
EMERGENCY MULTIPLIER: 7W Emergency (x 0.40)12W Emergency (x 0.68)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)
MXTG2-STRA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)
MXTG2-STRR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MX ADJUSTABLE L/M-012:19 P-53
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
Report #: ILL-02222016-01 (12) ILL-02222016-02 (24) ILL-02222016-03 (36) ILL-02222016-04 (50)
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL
D FC W L D C FC W L D C FC W L
MXTG2-STRA300WL33000K
12° Spot
6’8’
10’12’
675380243169
1.31.82.22.7
1.41.82.32.7
6’8’
10’12’
4567
396236149102
1.982.583.133.82
1.492.1
2.673.19
3’4’5’6’
4679
635396258176
1.151.491.892.55
2.422.963.484.24
MXTG2-STRA300WL33000K
24° Narrow Flood
6’8’
10’12’
30116910875.3
2.43.24
4.8
2.23
3.74.4
6’8’
10’12’
4566
17610165.245.4
3.24.195.226.24
2.643.354.165.03
3’4’5’6’
4578
33718811984.3
1.782.53.153.65
3.224.285.366.31
MXTG2-STRA300WL33000K
36° Flood
6’8’
10’12’
12369.144.330.7
3.95.26.57.8
3.54.75.87
6’8’
10’12’
3456
78.744.328.319.7
4.66.167.679.21
3.635.016.277.48
3’4’5’6’
3567
14284.455.639
2.763.464.335.13
45.346.477.64
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
MXTG2-STRA300WL3
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
2431694138562147210
6233
12467
18700
24934 10°
80°
70°
60°
50°
40°
30°20°
12° Spot (12)
Watts: 26Lumens: 1714 LPW: 66 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
1083890422703330425
2761
5522
8282
11043 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 26Lumens: 1805 LPW: 69 CCT: 3000K
35°
35°
1110
2220
3329
4439 10° 20°
36° Flood (36)
Watts: 26Lumens: 1702 LPW: 65 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
44254411262679316015a
80°
70°
60°
50°
40°
30°
MXTG2-STRA300WL33000K
50° Wide Flood
6’8’
10’12’
46.926.416.911.7
6.28.210.312.4
5.87.89.711.7
6’8’
10’12’
2334
35.119.512.58.8
5.767.769.6811.51
5.327.198.9710.67
3’4’5’6’
3456
67.838.224.417
3.464.75.846.99
4.185.56.898.2
442
884
1326
1768 10° 20°
50° Wide Flood (50)
Watts: 26Lumens: 1452 LPW: 56 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
16871763155889036196
80°
70°
60°
50°
40°
30°
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
EMERGENCY MULTIPLIER: 7W Emergency (x 0.35)12W Emergency (x 0.59)
CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)
MXTG2-STRA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)
MXTG2-STRR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MX ADJUSTABLE L/M-012:19 P-54
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
top related