doppler speed log - furuno...doppler speed log s complies with imo resolution msc.36 (63), msc.96...

Post on 24-Jan-2021

6 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

  • MMooddeell DDSS--5500DDOOPPPPLLEERR SSPPEEEEDD LLOOGG

    s Complies with IMO ResolutionMSC.36 (63), MSC.96 (72), A.694 (17),A.824 (19), IEC 61023 and othernational regulations

    s Displays ship's fore-aft and port-starboard speeds along withdistance run and keel clearance

    s Highly precise and stablemeasurement by using advancedthree-beam transmission technology

    s Compact display unit for ease ofinstallation

    s Auto mode for continuous readout ofship's speed

    s A variety of analog/digital speedindicators are optionally available formonitoring at a remote location

    s Signal outputs of analog/digitalspeed data and distance run forexternal equipment

    The FURUNO DS-50 is a Doppler Speed Logdesigned to meet the IMO Resolution, IECspecifications and other national regulations. Itsthree-beam transmission reduces the effect of pitchand roll for high accuracy and enables themeasurement of port-stbd speed as well as fore-aftspeed. Keel clearance information is provided toassist with shallow water navigation.

    The DS-50 measures and displays the ship's over-the-ground or through-the-water speed based onthe Doppler effect. Speed data can be output to

    external equipment such as ARPAs, INS and IBS.There are three operation modes: Ground-tracking,Water-tracking and Auto. The Auto modecontinuously displays ship’s speed, switchingbetween Ground-tracking and Water-trackingautomatically.

    The DS-50 consists of a display unit, processorand transducer. The compact design of the displayunit allows flexible installation on the bridge. Formonitoring at remote locations, analog and digitalindicators are optionally available.

    Catalogue No. M-1517c

    R

    R

    TRADE MARK REGISTEREDMARCA REGISTRADA

    The future today with FURUNO's electronics technology.

    FURUNO ELECTRIC CO., LTD.9-52 Ashihara-cho, Nishinomiya City, Japan Telephone: +81 (0)798 65-2111Telefax: +81 (0)798 65-4200, 66-4622 URL: www.furuno.co.jp

  • Distance indicatorDS-730

    Processor unit DS-511

    115/230 VAC

    **

    ***

    *******

    ****

    ****

    ****

    **

    Processor unit

    DS-510

    (Transceiver built in)or

    DS-511

    (Specify when ordering)

    Option

    Display unit

    DS-500

    30 mmax

    30 m max Remote box

    DS-501

    Digital indicator

    DS-350/351

    Distance signal (400 pulses/nm)

    1 port

    1 port

    2 ports

    1 port

    Distance signal

    (200 pulses/nm)

    Keying pulse

    Keying pulse

    6 ports

    1 port

    2 ports

    IEC 11622 ports

    115/230 VAC

    Shipyard supply

    *TTYCY-16S

    Distribution boxDS-370

    Alarm signal

    Alarm signal

    Distance signal (400 pulses/nm)

    Digital signal (speed)Analog signal (speed)

    Range switch boxDS-389

    Analog indicatorDS-381/382

    20 m

    400

    m m

    ax

    Junction box DS-360

    Transceiver unit DS-520

    20 m

    Transceiver unit DS-520

    Transducer

    Junction box CI-630

    Junction box DS-360

    10/15/20/30/100 m

    *

    * *

    *

    Transducer

    20 m

    100

    m m

    ax

    Junction box CI-630

    20 m

    Transducer DS-530with Transducer tank

    DS-531

    See below for connectionbetween processor and transducer.

    Processor unit DS-511

    Connection between processor and transducer

    Transducer DS-530with Transducer tank

    DS-531

    (Specify either Transducer tank DS-531 or Gate valve DS-532 when ordering)

    Power

    50 m max

    50 mmax

    50 m max

    100 mmax

    Processor unit DS-510 Processor unit DS-510

    10/15/20/30/100 m

    **TTYCY-4S

    ***TTYCY-2S****TTYCY-1S

    DOPPLER SPEEDLOG DS-50

    G

    Clearance

    m

    fa

    DIMMER

    AL/s

    kt

    ft

    T

    Keelistance

    AD

    W

    nm

    84 3.3"47 1.9"

    15 0.6"220 8.7"

    300

    11.

    8"

    212 8.3"(140 5.5")

    272

    10.

    7"

    (258

    10.

    2")

    4-5x16

    670 26.4"

    (630 24.8")

    600 23.6"

    640

    25.

    2"

    (410

    16.

    1")

    4- 12

    678

    26.

    7"

    38 1.5"

    284

    1000 39.2"

    718 28.3"

    840

    33.

    1"

    443 17.4"

    400 15.7"

    300

    11.

    8"

    350

    13.

    8"

    2- 15

    216.3 8.5" 150 5.9"

    25 1.0"

    EQUIPMENT LIST (Specify type of processor unit when ordering)Standard for installation with DS-510 (Transceiver unit built in)1. Main display unit DS-5002. Processor unit DS-510 (Transceiver built in)3. Transducer DS-530 with 20 m cable4. Transducer tank DS-5315. Installation materials and spare parts

    Standard for installation with DS-511 (Transceiver unit separated)1. Main display unit DS-5002. Processor unit DS-5113. Transducer DS-530 with 20 m cable4. Transducer tank DS-531 or Gate valve DS-532 (specify when ordering)5. Transceiver unit DS-5206.Installation materials and spare parts

    Optional (Common)1. Analog indicator DS-381/3822. Digital indicator DS-350 (LCD display, waterproof)/351 (LED display)3. Distance indicator DS-7304. Distribution box DS-3705. Range switch box DS-3896. Junction box DS-3607. Junction box CI-6308. Extension cable between DS-510-CI-630/DS-520-CI-630

    66S1067 (10, 15, 20, 30 or 100 m)9. Remote box DS-501 for Main display

    02045Y Printed in Japan

    DISPLAY UNITTwo-digit LED for display of port-stbd speedThree-digit LED for display of fore-aft speedSeven-digit LED for display of distance run/keel clearance

    ULTRASONIC FREQUENCY440 kHz

    NUMBER OF BEAMS3 beams for dual axis speed indication

    MEASURING RANGE AND ACCURACYShip's speed

    Fore-Aft: -10.0 to 40.0 knotsPort-Stbd: -9.9 to 9.9 knots

    Measurable depth of ship's speedGround tracking: 1 to 200 m below hull bottomWater tracking: 2 to 25 m below hull bottomTotal distance run: 0 to 99999.99 nm

    AccuracyShip's speed: ±1% or ±0.1 kt, whichever is greaterDistance run: ±1% or ±0.1 nm, whichever is greaterKeel clearance: ±1% or ±0.1 m, whichever is greater

    (At 1,500 m/s sound velocity)

    INPUT/OUTPUT SIGNALSInput 2 ports for external keying pulseOutputShip's speed 3 ports* (Digital)

    1 port (Analog)Distance signal 1 port* (400 pulses/nm)

    6 ports with contact closure signal at 200 pulses/nm

    Alarm signal 1 port*Keying pulse 1 port

    Input/Output 2 ports for IEC61162 data* For those needing more ports, Distribution box DS-370 is optionally available

    ENVIRONMENT (IEC 60945 test method)Temperature: -15°C to +55°C

    POWER SUPPLY115/230 VAC

    Display unit DS-500

    Gate valve DS-532(option)

    Interconnection Diagram

    Transducer DS-530with tank DS-531

    Processor unitDS-510

    Cutout for flush mount

    SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

    SPECIFICATIONS OF DS-50

    FURUNO U.S.A., INC.Camas, Washington, U.S.A.Phone: +1 360-834-9300Fax: +1 360-834-9400

    FURUNO (UK) LIMITEDHavant, Hampshire, U.K.Phone: +44 2392-441000Fax: +44 2392-484316

    FURUNO FRANCE S.A.Bordeaux-Mérignac, FrancePhone: +33 5 56 13 48 00Fax: +33 5 56 13 48 01

    FURUNO ESPAÑA S.A.Madrid, SpainPhone: +34 91-725-90-88Fax: +34 91-725-98-97

    FURUNO DANMARK ASHvidovre, DenmarkPhone: +45 36 77 45 00Fax: +45 36 77 45 01

    FURUNO NORGE A/SÅlesund, NorwayPhone: +47 70 102950Fax: +47 70 102951

    FURUNO SVERIGE ABVästra Frölunda, SwedenPhone: +46 31-7098940Fax: +46 31-497093

    FURUNO FINLAND OYEspoo, FinlandPhone: +358 9 4355 670Fax: +358 9 4355 6710

    FURUNO POLSKA Sp. Z o.o.Gdynia, PolandPhone: +48 58 669 02 20Fax: +48 58 669 02 21

    FURUNO DEUTSCHLAND GmbHRellingen, GermanyPhone: +49 4101 838 0Fax: +49 4101 838 111

    LLC "FURUNO EURUS"St. Petersburg, Russian FederationPhone: +7 812 167 15 92Fax: +7 812 766 55 52

top related