data sheet ipdslam r2.8
Post on 04-Apr-2018
217 Views
Preview:
TRANSCRIPT
-
7/30/2019 Data Sheet Ipdslam r2.8
1/7
Multi-Service IP DSLAM
SURPASS hiX 5622/25/5630/5635Release 2.8
Carrier Ethernet Comprehensive SolutionsThe Nokia Siemens Networks hiX 5622/5625/5630/5635 seriesof IP DSLAM is an innovative platform for access networks toprovide broadband services on the last mile of the network
i pl
, f
f.t
t
tt
f ,
I f.
It fI t
/ +
I
f
t
All-in-OneMulti-service IPDSLAM with all DSL
flavours.
Scalability guarantees best
fit to your specific solution
requirements
Flexible & modular solution
for Central Office (CO) or
remoteshelter for DSL
deployment
-
7/30/2019 Data Sheet Ipdslam r2.8
2/7
General DSLAM Specifications
Mass rollout platform with universal slot
architecture for Interface Units (IU)
M series Chassis support 1 Gbps slot
capacity ( M400 / M600 / M1100 )
G series Chassis are prepared to
deliver up to 10 Gbps capacity per slot (
G200 / G400 / G600 / G1100) for any
future high bandwidth demanding
applications
Non Blocking Architecture (48 Gbps
switching)
GE Star from Central Card to each IU
slot
DC Powering (-48 V)
Redundant DC Power supply
Optional External AC Power supply
Optional External Redundant AC Power
supply
Fan Redundancy
Redundancy for Switch/Control Card(no CXU redundancy for hiX5622)
Chassis design for 19 / ETSI rack
mounting (G200 and G400 not for 19)Front access including Control & Switch
Fabric
Central Office (CO) & Outdoor Cabinet
installation for hiX 5625 / hiX 5630, CO
for hiX 5635
Outdoor Cabinet & Indoor (building and
basement) installation for hiX5622
Separate shelf for splitters
Subtending interfaces option
Remote testing capability
IPv6 Hardware readiness
M400 shelf of hiX 56256 Slots (1CXU + 5 IU or 2 CXU (redundant)
+ 4 IU ) / horizontal layout
M600 shelf of hiX 5630
10 Slots (1 or 2 CXU (redundant)+ 8 IU) / horizontal layout
M1100 shelf of hiX 5635
16 Slots (1 CXU + 15 IU or 2 CXU
(redundant) + 14 IU ) / vertical layout
G200 shelf of hiX 5622
3 Slots (1 CXU + 2 IU ) / horizontal layout
G400 shelf for hiX 5625
The G400 shelf is an alternative forcustomers who want to be prepared forfuture planned higher capacity interfaceunits. Although the design is similar to theM400, the backplane is capable to offer upto 10 Gbps per slot. The G400 shelf fits in23 or ETSI rack.
G600 shelf for hiX 5630
The G600 shelf is an alternative forcustomers who want to be prepared forfuture planned higher capacity interfaceunits. Although the design is similar to theM600, the backplane is capable to offer upto 10 Gbps per slot. The G400 shelf fits in23 or ETSI rack.
G1100 shelf for hiX 5635
The G1100 shelf is an alternative for
customers who want to be prepared for
future planned higher capacity interface
units. Although the design is similar to the
M1100, the backplane is capable to offer up
to 10 Gbps per slot.
1 or 2 x CXUs possible (second card
for 1+1 redundancy, standby
architecture)
CXU has 4 GE interfaces (different
SFP modules are available)
GE interface types available:
Electrical SFP 100/1000 Base-T
auto-negotiation
Optical-SFP / (LX) single mode / (SX)
multi mode
Per port assignment of uplinkinterface, e.g. network interface
(uplink) or cascading daisy uplink
protection with use of link aggregation
(LAG), LACP
Service Interface Units:
72 Port ADSL2+
(backward compatible
with ADSL and ADSL2)
48 Port SHDSL.bis (support SHDSL)
24 Port VDSL2
48 Port VDSL2
Number of slots dedicated for IU
2 slots in G200 chassis
5 slots in M400 chassis
8 slots in M600 and G600 chassis
15 slots in M1100 chassis
4 slots in G400 chassis
14 slots in G1100 chassis
Maximum number of subscribers per sub-
rack with 72 ADSL2+ or VoIP ports per
Interface Unit:
Up to 360 for hiX 5625 (M400)
Up to 576 for hiX 5630 (M600/G600)Up to 1080 for hiX 5635 (M1100)
Up to 144 for hiX 5622 (G200)
Up to 288 for hiX 5625 (G400)
Up to 1008 for hiX 5635 (G1100)
-
7/30/2019 Data Sheet Ipdslam r2.8
3/7
-
7/30/2019 Data Sheet Ipdslam r2.8
4/7
-
7/30/2019 Data Sheet Ipdslam r2.8
5/7
Physical Data hiX 5622/5625/5630/5635
hiX /Horizontal layout with 10 GE star bus architecture
Subrack size (h x w x d)
122 mmx 494 mmx 279mm(23 and ETSI) ~ 2,8 U
Subrack size with cables
122 mm x 494 mm x 315mm (h x w x d)
Power supply
2 redundant DCconnectors for -48 V DC / -60 V DC
Workingbetween -40,5 ...-72,0 V
Power-consumptionFullyequipped(144ADSL2+ lines): max.270 W
Temperature range
AccordingtoETSIEN300 019-1-3, class 3.3 (25 to+55 C)
For outdoor installationa typical sun radiation add-onof +15 Cmust
be considered, resulting in an upper temperature limit of +70 C
hiX 5622 G200
hiX /Vertical layout with 1 GE star bus architecture
Subrack size
536 mmx 444.5mmx 279 mm(19 and ETSI) ~ 12U
Subrack size with cables
536mm x 444.5 mm x 315 mm (h x w x d)
Power supply
2 redundant DCconnectors for -48 V DC / -60 V DC
Workingbetween-40,5 ...-72,0 V
Power-consumption
Fully equipped (1080 ADSL2+ lines): max. 1700 W
Actual power consumption will dependonthe numberof
simultaneous connections andpower modes in whichthese
lines arerunning (normal/L2/L3)
Temperature range
According toETSIEN300 019-1-3,class 3.3 (25 to+55 C)
For outdoor installation a typical sun radiation add-onof +15 C
must
be considered, resulting in an upper temperature limit of +70C
hiX 5635 M1100
hiX /Vertical layout with 10 GE star bus architecture
Subrack size (h x w x d)
536 mm x 444,5 mm x 279 mm (19 and ETSI) ~ 12U
Subrack size with cables
536 mm x 444,5 mm x 315 mm (h x w x d)
Power supply
2 redundant DC connectors for -48 V DC / -60 V DC
Working between -40,5 ...-72,0 V
Power-consumption
Fully equipped (1008 ADSL2+ lines): max. 1600 W
Actual power consumption will depend on the no. of
simultaneous connections and power modes in which
these lines are running (normal/L2/L3)
Temperature range
According to ETSI EN 300 019-1-3, class 3.3
(25C to +55 C)
For outdoor installation a typical sun radiation add-on of
+15 C must be considered, resulting in an upper
temperature limit of +70 C
hiX 5635 G1100
-
7/30/2019 Data Sheet Ipdslam r2.8
6/7
hiX /
Horizontal layout with 10 GE star bus architecture
Subrack size (h x w x d)
224mm x 494mm x 279 mm (23 and ETSI) ~ 5U
Subrack size with cables224mm x 494mm x 315 mm (h x w x d)
Power supply
2 redundant DC connectors for -48 V DC / -60 V DC
Working between -40,5 ...-72,0 V
Power-consumptionFully equipped (288 ADSL2+ lines): max. 550 W
Temperature range
According to ETSI EN 300 019-1-3,
class 3.3 (25C to +55 C)
For outdoor installation a typical sun radiation
add-on of +15 C must be considered,resulting in an upper temperature limit of +70 C
hiX 5625 G400
hiX /
Horizontal layout with 1 GE star bus architecture
Subrack size (h x w x d)
221.5mm x 443,8 mmx 279 mm (19 and ETSI) ~ 5U
Subrack size including with cables221.5mm x 443.8 mm x 315 mm(h x w x d)
Power supply
2 redundant DCconnectors for -48 V DC / -60 V DC
Working between -40,5 ...-72,0 V
Power-consumption
Fullyequipped (360ADSL2+ lines): max.600 W
Temperature range
According toETSIEN300 019-1-3, class 3.2 (5C to+45 C)
hiX 5625 M400
hiX /Horizontal layout with 1 GE star bus architecture
Subrack size (h x w x d)
310,3 mmx 443,8mmx 279 mm(19 and ETSI) ~ 7U
Subrack size with cables
311 mm x 443.8mm x 315mm(h x w x d)
Power supply
2 redundant DCconnectorsfor -48 V DC/ -60 V DC
Working between -40,5 ...-72,0 V
Power-consumption
Fully equipped(576 ADSL2+ lines): max.1000 W
Temperature range
AccordingtoETSIEN300 019-1-3, class 3.2 (5 to+45 C)
hiX 5630 M600
-
7/30/2019 Data Sheet Ipdslam r2.8