COMMUNICATION FOUNDATION
HART
HART + DDL
Core HART Technology Supporting Universal Access to ALL
Capabilities of ALL HART Field Devices
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 2 of zzzz
Rosemount 1151S At HART Foundation >12 Years
– In Foundation Office When I Joined !– Device Revision 5(Not the newest revision of 1151S)
Its EDD was Written 1993/*
* 1151SII Rev 5 HART Device Description * * HART Communicator Toolkit rev G * * Garrie Huisenga 6/3/93 * Updated 10/14 by Chip Rauth to add 2nd precision tables, * changed g formats to e formats * DD rev 2 to use RMTPRES5 and more like 3051C
*/
Rosemount Still Ships 1151s– Millions in Plants*
(* according to Rosemount Website)
– Customers Require Support
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 3 of zzzz
The 1151S' EDD Today
Exactly Same EDD– Still Works – Devices in Plants
Still Supported– 13 Year Old DD
Where are the people who wrote this EDD?
On old devices, who updates the EDD so it works today?
Does your computer run MS-Windows 3.11?Does your computer run MS-Windows 3.11?
DD-IDE and SDC-625 DD-IDE and SDC-625 The HART StandardThe HART Standard
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 4 of zzzz
EDDL = Longevity A Plant is built to Last
– HART Devices in for Long Haul– Customers expect support
EDD's Last, too!– Computers Change– Companies Merge, Reorganize– Staff Migrates, Change Jobs
HCF Committed to EDDL– Protect Industry Investment– Provide High-Productivity EDD
Development and Test Tools– Open access to EDD technology
Simatic PDM
EDDs keep On Working !
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 5 of zzzz
DDL Started with HART
1990 "International Fieldbus Group" Notion of DDL
1991-1993 DDL and HC-275 presented at HUG 1994 HCF DD Library established for
registration and distribution 1994 First HCF DD Workshop 1995 Large HC-275 shipments begin 1996 FF Adopts DDL 2001 DDL IDE project initiated
– Enhance DD Developer Productivity– Access to DDL Technology by all HART members
2003 EDDL Cooperation Group Starts 2004 EDDL Approved by IEC 2004 DD-IDE & SDC-625 Released 2004 Honeywell FDCM & handheld released
– First SDC-625 based host. 2005 HCF SDC-625 Supports 100% of EDDL Enhancements 2005 New HART DDL Specifications Approved 2006 EDDL with Enhancements Approved by IEC ** Actually HCSIMActually HCSIM
HC-275 SimulatorHC-275 Simulator
HART CommunicatorHC-275
Brief DDL History
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 6 of zzzz
Elements of an EDD Data Modeling
– Fundamental EDDL Capability– Models Field Device Real-Time Database
Smart Field Device like RTU in SCADA– Other EDD Declarations Refer to Data Model
Communications– Defines all communications capabilities– EDD Application Chooses What and When to
Communicate HMI
– Allows a User to Browse Field Device– EDD Developer Determines Organization
and Content– Host Application Determine Look and Feel
Methods– Models Standard Operating Procedures (SOPs)– Ensures User Performs Procedure Consistently
Data ModelData Model
Communications Communications
Meth
od
s M
etho
ds
HMI HMI
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 7 of zzzz
EDDL Technology No Other Programming Language
Like EDDL
An EDD is a Text-Based Model of the Field Device
– Developers Describes What Capabilities are in their Field Device
– NOT How the Application should use the Field Device
– Supports Simple to Complex
Host Application Interprets the EDD– Developer focuses on the
EDD Application– Provides a secure "window" to
browse the Field Device– EDD describes the Application's
view of Field Device using MENU
EDDL is the right dividing line between Field Device and EDD Application developers
Field Communicator375-FC
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 8 of zzzz
EDD's are Portable Operating Systems
– Unix (Solaris)– Windows NT, 2000, XP (SDC-625,
PDM, AMS, FDM, etc.)– Embedded (HC-275, 375-FC)
Processors– ARM– Wintel– Motorola 68302
Protocols– HART– PROFIBUS– FOUNDATION FIELDBUS
– Others
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 9 of zzzz
QuickTime™ and aTIFF (Uncompressed) decompressor
are needed to see this picture.
HART EDDL Today HCF DD Library
– >60MBytes of Encoded EDDs– 1079 DDs, 438 devices, 100 manufacturers– 3.6 Million Lines of Code– Adding 150 EDD's per Year– Stable and field-proven for long life
Continuing Investment in EDDL Technology– Enhancements to EDD Language– Tools for EDD Developers,
Host Applications– Continuous Quality Improvement– Industry Education– Simplifying Access to HART EDD Library
EDDL is the Only Technology Endorsed by the HCF for the Configuration of HART Devices
EDDL is the Only Technology Endorsed by the HCF for the Configuration of HART Devices
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 10 of zzzz
One Encoded EDD works on all Hosts– The real promise of EDDL– Real EDD portability– Lower host and field device development costs– Provide end user access to DD's
Critical DD Development Tools controlled by HCF– DD-IDE Tool Suite and SDC625 reference Host– Managed and maintained as HCF standards
SDC625 (HCF Interpreter) licensed by HCF members for inclusion in commercial products– Ensures correct interpretation of DDs and full benefit of testing,
validation and registration process
DDL is the HART Standard
Write it OnceWrite it OnceTest It OnceTest It OnceUse It AnywhereUse It Anywhere HandheldHandheld
PC-based PC-based ConfiguratorConfigurator
Instrument Instrument ManagementManagement
DDDD
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 11 of zzzz
EDDL Quality Assurance HART DD Library Registration Key to EDD QA
All EDDs must registered and verified with reference Host(source files archived, symbols controlled)– Well defined process for Registering EDDs– Detailed, Repeatable process to ensure Consistency, Quality– Process updated as loop-holes identified
All EDDs distributed as single encoded file to ensure security and integrity – this file must work on all EDD compliant Hosts
Evolving, improving since 1994
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 12 of zzzz
Backward Compatibility A Core HART Value
– HART Specifications detail how a revision is made to a field device – You can replace an old device with a new one without changing the host
application.» New Revisions work in place of old revisions.
– You can Add to a device (Commands, Data)– You can't change what's already in the device
Backward Compatibility in EDDs: – Compliance detected by auditing symbols
» Symbol = Name of Data, Command, Menu, etc» Symbol changes, additions, deletions detects
– No Changes to EDDL that break an Existing EDD.– All Hosts must support registered EDDs
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 13 of zzzz
Continuous Quality Improvement Big Need to start testing host applications
EDDL Interoperability Guidelines – Basic host interoperability – Documents Enhancements
EDDL Common Test Requirements– Identify test requirements common to all Protocols– Focus on Host Requirements First
HART EDDL Working Group– Addressing HART-Specific Requirements– Beginning work on actual test program
HART Interoperability Workshops– Held twice a year– Sharing between host and EDD developers– Everyone in one room.
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 14 of zzzz
The EDDL Enhancements – The Evolution Continues
Growing acceptance of DDL and increasing complexity of devices created the need for improved user display
Enhanced DDL extends capabilities to support graphical Windows display of device information– + Graphic objects, charts, trends– + Storage of device data in Hosts – + Increased computation for managing complex devices
International Standard - IEC 61804, EDDL
EDDL Cooperation Team (ECT) established by HART, PNO, FF and OPC to further the technology and maintain IEC Standard
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 15 of zzzz
First Enhanced DD Registered at HCF Enhanced DDL marks a significant change
– Applications can now maximize the full capability of intelligent field devices
– Reduces the need for custom device configuration and diagnostic software
Configuration and monitoring is now easier and faster– Reduces errors and downtime
An International Standard - IEC 61804, EDDL
Built on experience, designed by experts
EDDL Technology – Safe, Secure and Robust
COMMUNICATION FOUNDATION
HARTCopyright - HART Communication Foundation, 2006Page 16 of zzzz
One Encoded EDD for ALL Host Applications
HCF Reference Host SDC-625
SiemensSimatic PDM
EmersonAMS Device Manager
top related