1 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Flexi Multiradio BTS Commissioning and Integration

2 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Content

Preparing for Commissioning

2G Flexi BTS Manager

Commissioning Types

Creating SCF File (Offline)

Local Commissioning

Demonstration

3 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for Commissioning

4 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningCommissioning Prerequisite (1/2)

• Before commissioning, the physical installation of the BTS (modules, cabling, antennas and radios) must be completed.

• Make sure a PC with 2G Flexi BTS Site Manager installed.

• One 10/100 Mbit/s Ethernet cable needed for the connection between the BTS and user PC.

• Parameter values must be available to be entered during commissioning. The parameter values are provided by the network planning process.

• BSC settings: the BTS site must already be created at the BSC for commissioning to be successfully completed.

5 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningCommissioning Prerequisites (2/2)

• Transmission network setup: the transmission link(s) between the BSC and the BTS must already be set up so that there is a transmission path from the BSC to the BTS for all the Abis channels.

• If there are any intermediate transmission hubs between the BSC and the BTS, the cross connections in the hubs should either be set up at the E1/T1 link level, or at the n x 64 kbit/s level for all the channels to the BTS in an E1/T1 link.

• With the Flexi transmission interface Flexbus sub-module (FIFA), the transmission link will be established during commissioning.

Screenshots included are representations and should be considered as examples only. The current release of the 2G Flexi BTS Site Manager software may differ slightly from the shots depicted

6 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningVisual Check Inspections

• Perform the first part of the visual check before powering on the BTS at the power system.

• Check the equipment visually to see that there are no fatal installation errors, which might lead to equipment damage during the power on, such as

– the grounding– power cabling and supply voltage– other cables and fibres– LED status during power up– TX/RX/antenna connector torque check– Flexbus cables (used with FIFA)– LAN cable (used with the E1 transmission card)– LAN cables (used for TDM or Fast Ethernet transmission with FIPA, FIEA, FIQA,

FIYA)– Optical fibres (used for Gigabit Ethernet transmission with FIQA, FIYA)

• When all is proven to be OK, perform the 'Power on' check and verify the LED status.

7 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (1/4)

• Software needed in order to do commissioning/ supervising the Flexi Mutiradio is 2G Flexi BTS Site Manager (mandatory) and Flexi Hub manager (if FIFA is used).

• Both Software can be downloaded via NOLS.

• Please ensure that both manager software must be compatible with the software level installed in the BTS.

• User can check the compatibility at Software compatibility of Flexi Multiradio BTS document in NED.

8 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (2/4)

• Check the system requirement of the PC before install the site manager

9 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (3/4)

• Install the 2G Flexi BTS Manager and follow the instruction on the installing wizard.

• On successful completion of installation shortcuts will be created on your desktop and in the Start menu to launch the 2G Flexi BTS Site Manager.

10 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (4/4)

• On successful completion of installation shortcuts will be created on your desktop and in the Start menu to launch the 2G Flexi BTS Site Manager.

Note:1.On certain computers, you may also be required to restart your computer before running the application.2. Re-installing the same version of the product will over-write the previous configuration with the default settings.

11 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS Manager

12 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window

• To launch the 2G Flexi BTS Manager user can click shortcuts in the Start Menu, and following window will come up.

For commissioning/ supervison if PC connect dircctly to BTS

For re-commissioning/ supervison if PC connect BTS via NetAct (remotely)

For creating the SCF or EasyWizard Template if PC connect BTS offline (PC not connected to BTS)

For help

List of release package and 2G Flexi BTS Site Manager versions

List of release package and 2G Flexi BTS Site Manager versions

13 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Local connection option, then come this following window

IP Address of ESMB/C

As defult: no password, just left this box blank

For detail see comissioning process part

14 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Remote connection option, then come this following window:

Mandatory to fill

15 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Create File option, then come this following window:

Release packages and 2G Flexi BTS

Site Manager versions

For detail see Creating SCF file offline

16 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Tool option, then come this following window:

Available tools (help for BTS Site Manager)

17 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Tool option, then come this following window:

List of installed Release packages and 2G Flexi BTS Site manager version

18 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning Types

19 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning typesCommissioning Process Goal (1/2)

• The commissioning process is divided into 4 different commissioning processes depending on the connection and commissioning statuses:

– BTS is not connected: The user intends to create SCF file or an EasyWizard template.

– BTS is connected and uncommissioned: The user wants to bring up the BTS in functional state. He can either use an EasyWizard like template or can specify the settings manually

– BTS is connected and commissioned:  The user wants to upgrade the configuration or can change the configuration. This may either simply append in existing configuration or may lead to recommissioning of BTS based on the new settings to be upgraded or changed.

– BTS is connected remotely and commissioned:  The user wants to upgrade the configuration or can change the configuration. This may either simply append in existing configuration or may lead to recommissioning of BTS based on the new settings to be upgraded or changed.

20 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning typesCommissioning Process Goal (2/2)

• The possible ways to perform commissioning process are: – Use existing SCF (Site Configuration File)

– Upload SCF from BTS

– Create SCF by manual commissioning using Commissioning Wizard

• Note: User should not modify the Site Configuration File by using XML editor. Only the BTS Manager should be used to change any values in SCF.

• The Commissioning Wizard will guide user through configuration. By clicking "next" button the wizard will continue to the next configuration screen

• The wizard consist following screen:– Site specific Information

– Hardware Configuration

– Transmission Parameter

21 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning TypesBTS is not connected

22 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning TypesBTS connected-uncommissioned

23 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning Types BTS connected-commissioned

24 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning Types BTS connected remotely-commissioned

25 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)

26 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Select Create File from main window

• If the BTS is not connected the user intends to create SCF file or an EasyWizard template.

• From the 2G Flexi BTS Site Manager main window choose Create File select packages and 2G Flexi BTS Site Manager versions in the dropdown menu click “create” button:

1

2

3

27 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Commissioning menu

28 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Create EasyWizard Hardware & Transmission template

The file created will be with extension .epb

The file created will be with extension .ept

29 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Create SCF (Complete SCF)

The file created will be with

extension .xml

The file created will be with

extension .xml

30 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning

31 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningIP Setup for Local Commissioning PC

• Connect via LMP on ESMx using ethernet cable

• Setup the local IP address on PC under Internet Protocol (TCP/IP) properties as follow:

IP address: 192.168.255.130

Subnet Mask: 255.255.255.128

Default Gateway: none

• Personal Firewall may need to allow access to local network

eg ZoneAlarm

• The default settings of the BTS are:

IP address: 192.168.255.131

2G Flexi BTS Site Manager connection TCP Port: 27500

• 2G Flexi BTS Site Manager SW download via TCP Port: 27501

32 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Flexi 2G BTS Site Manager (1/2)

• Nokia Siemens Networks 2G Flexi BTS Site Manager allows the BTS operators to

– Commission

– Configure

– Monitor the BTS

• These tasks are performed with option:– at the BTS site (known as Local

Connection)

– via communication from the NMS system.

– BSC site (known as Remote Connection).

• 2G Flexi BTS Site Manager is for maintaining and commissioning Flexi Multiradio base transceiver stations.

33 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Flexi 2G BTS Site Manager (2/2)

Local Connection directly to Flexi Multiradio BTS

GSM/EDGE

Remote Connection via NetAct

Create file (commissioning file

IP address of System Module, and Password

just keep empty

Create File is to create the template or SCF

34 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningLocal Connection

35 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Flexi 2G BTS Site Manager window

The main functions of Flexi BTS manager are: • BTS

commissioning• BTS supervision• BTS maintenance• BTS testing

In main menu, the view are:• Alarms• Base Station• Commissioning• Supervision• Transmission• Tests

Navigation bar

Logical BTS view

Properties

Alarms view

Connection feeedback

36 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningCommissioning Wizard

Select the Commissioning → Wizard menu item or click the Commissioning

button on the View Selection Bar.

37 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningUndo Commissioning (1/4)

• to revert the site to un-commissioned mode and he can also check the option that whether user wants to erase bypass capacity along with it or no.

• This button is disabled in remote

connection

38 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningUndo Commissioning (2/4)

39 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningUndo Commissioning (3/4)

Indicate the BTS has successfully uncommissioned

40 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Undo Commissioning (4/4)

• If the BTS is in un-commissioned mode, the connecting RF module is not automatically detected

• Connecting RF module will be detected if the BTS has been commissioned

41 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Commissioning Manually

• In this example, user do commissining manually

42 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Commissioning Manually - Procedure

• Site Specific Information

• Hardware Configuration

• Module Configuration

• Local Sector Settings

• Antenna Settings• RET Setting

• FRM EAC Settings

• Battery Backup Unit

• Other Passive Units

• Transmission parameter

• Physical Setting

• LIF Settings

• Synchronization

• Abis Termination• Abis Allocation

• Abis Protection

• Cross Connection

• Q1 Management

43 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Navigation tree - Enables

user to navigate any screen, and update/view parameters

corresponding to that screen.

Data persistence is

maintained across screen navigations

Local Commissioning Site Specific Information

Navigation tree - Enables

user to navigate any screen, and update/view parameters

corresponding to that screen.

Data persistence is

maintained across screen navigations

44 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration

• If user has hardware template file (.epb or SCF file), specify from file can be selected

• In this example specify manually is selected

45 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration – Module Configuration

configure various radio modules, synchronization master, and radio masters

46 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningHardware Configuration – Local Sector setting

configure and associate antennas of only one type of RF unit (RM) to a particular local sector and specify per TRX power

47 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration – Antenna Settings

Select the antenna line settings, specify MHA settings, provide information for feeder voltage, feeder loss, VSWR minor and major limits for the selected antenna

48 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

User can change the Received Signal Strength Indicator (RSSI) sample count

Local Commissioning Hardware Configuration – Antenna monitoring parameters

49 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

configuration of RETs in either online or offline mode

Local Commissioning Hardware Configuration – RET settings

50 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration – RFM EAC settings

configure the external alarm lines associated with the individual FRMs

51 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningHardware Configuration – Battery Backup Unit

Enter the battery backup unit parameters

52 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningHardware Configuration – Passive Units

Enter the passive unit parameters

53 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter

• If user has transmission template file (.ept or SCF file), specify from file can be selected

• Upload from BTS used if user want to oads the transmission configuration from the BTS and which can then be edited by the user, if required

• In this example specify manually is selected

54 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Physical settings

• Setting the functionality of interface (E1 or T1)

55 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Transmission Parameter – LIF Setting

• Setting the use interface settings, modify the CRC (if required) and name of the interface

56 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Synchronization (Source)

• Select the E1 for synchronizaton reference and modify the priority of the reference synchronization among defined E1

57 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Synchronization (Protection)

• Define the topology (default is Chain)

• user can define the synchronization protection if the topology is Loop

58 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Synchronization (Output)

user can enable or disable the 2MHz clock output from one BTS, to be used as the synchronization source for any other connected BTS.

59 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Transmission Parameter – Abis Termination

• In Satellite Abis, specify if there is a satellite circuit in the link between the BTS and the BSC

• Enable Abis Signal Mapping allows the BSC to dynamically provide the Abis allocations (TRXSIG, TCH, EDAP) for a BTS

• If Allow Abis Allocations from BTS Manager is thicked (enabled), user can allocate the Abis allocations from the BTS Manager but these allocations can be overridden by the BSC

60 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Transmission Parameter – Abis Allocation

• Enter the Abis Allocation parameters (OMUSIG, TRXSIG, TCH and EDAP)

• If Enable Abis Signal Mapping is chosen, only OMUSIG can be specified, the rest will be mapping by the BSC

• If Enable Abis Signal Mapping is chosen and Allow Abis Allocations from BTS Manager is thicked , all signaling can be allocated in Abis, but these allocations can be overridden by the BSC

61 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Abis Protection

• If Loop topology is used, Abis protection can be defined

62 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Cross Connection

63 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningCross Connection – Q1 Management

64 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningFlexhub

•User need to install the FlexiHub Manager beforehand

65 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningSCF preview - Summary

• From this summary, user can check whether the commissioing step has been completed.

• This can be checked by looking at the indication color of each step, green means ok, red means not complete

66 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning SCF preview - Detail

67 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningViewing the commissioning progress and the commissioningresult

68 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningCommissioning completeted

69 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Commissioning Report

Executive Summary

Detail Report

Old

est

70 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningExample if the TRX test is failed

71 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning BCF Object after commissioning

72 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Cell Object after commissioning

73 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning TRX Object after commissioning

74 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Tracing the traffic during the test call

• From the toolbar select Test menu select Traffic trace select cell would be traced --> click Automatic Update (if necessary)

• For the CS call, yellow color indicates the RTSL that being occupied

75 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Fetch SCF from BTS

• From the toolbar select Commissioningmenu select Fetch SCF from BTS Save the SCF file (.xml) in local PC

76 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Fetch the commissioning report

• From the toolbar select Commissioning menu select Report select Fetch from BTS Save the Commissioning Report in Local PC

77 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Site Information

• From the toolbar select Supervision menu select Site Information Save the Site Information file in Local PC

78 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Check on the BSC (1/2)

• Using MML command: ZEEI: <bcf_id>; user can check the status of BTS object under specific BCF.

OADING PROGRAM VERSION 22.4-1BSC LINDA 2010-05-10 16:38:19RADIO NETWORK CONFIGURATION IN BSC: E P B F T R C D-CHANNEL BUSY AD OP R ET- BCCH/CBCH/ R E S O&M LINK HR FR LAC CI HOP ST STATE FREQ T PCM ERACH X F U NAME ST /GP===================== == ====== ==== == ==== =========== = = == ===== == === ===

BCF-0051 FLEXI MULTIRADIO U WO 0 OM051 WO 00220 22010 BTS-0010 U WO 0 2 DEMOBTS1 -/- 6 TRX-001 U WO 12 0 51 MBCCHC P 0 TRX-002 U WO 20 0 51 0 TRX-003 U WO 30 0 47 3 TRX-004 U WO 40 0 47 3 00220 22011 BTS-0011 U WO 0 2 DEMOBTS2 -/- 6 TRX-005 U WO 50 0 51 MBCCHC P 1 TRX-006 U WO 60 0 51 1 TRX-007 U WO 70 0 47 3 TRX-008 U WO 80 0 47 3 00220 22012 BTS-0012 U WO 0 2 DEMOBTS3 -/- 1 TRX-009 U WO 90 0 51 MBCCHC P 1 TRX-010 U WO 100 0 51 1 TRX-011 U WO 110 0 47 3 TRX-012 U WO 120 0 47 3