CFSeo-FA
CFS-NV • Communal Flue System - Naturally Vented negative pressure
CFS-FA • Communal Flue System - Fan-Assisted positive pressure
CFSeo-FA • Communal Flue System exhaust only - Fan-Assisted
NEWfor buildings2-24 floors
BK-C
G-00
2-GB
• 0
4-20
08-1
.000
Cox Geelen
Emmastraat 92 • 6245 HZ Eijsden • PO-Box 6 • 6245 ZG Eijsden • The NetherlandsT +31 (0)43 40 99 500 • F +31 (0)43 40 91 987 • sales@coxgeelen.com • www.coxgeelen.comKvK Zuid-Limburg 14608324
Member of BERGCOX chimneys and ventilation group
D1 20 KW HE24 KW SE
25 KW HE30 KW SE
30 KW HE36 KW SE
35 KW HE42 KW SE
130 2 2
150 3/4/5 3 2
180 6/7 4/5 3/4 2/3
200 8/9/10 6/7 5/6 4/5
225 11/12/13 8/9/10 7/8 6/7
250 14/15/16 11/12/13 9/10/11 8/9
280 17/18/19/20 14/15/16 12/13/14 10/11/12
300 17/18/19/20 15/16/17 13/14/15
350 18/19/20 16/17/18
400 19/20
T-piece 1 connecTionØ 80 Ø 130 L=1550
FLUe pipe
condensaTe base UniTWiTH adJUsTabLe FLooR sUppoRT
A complete communal flue system, providing exhaust gas and condensate removal only from multiple heating and hot water gas fired appliance installations. Fan assisted positive pressure operation allows the system to become more space saving where local room sealed air supply is preferred.CFSeo-FA is Cox Geelens single pipe complete flue exhaust system for use with room sealed gas fired condensing (HE) and non condensing (SE) boilers and fits perfectly with the latest generation gas fired heating appliances with flue connection Ø 60 and 80 mm. This system is also CE Marked in accordance with European Standards EN 1856-1 .
Special features:
• The aluminium pipe has a 1.5mm wall thickness, has a longitudinal TIG-welded seam with its female end fitted with the latest Fix-Safe seal (FS) for a gas-tight and condensate-tight push fit joint.
• The elasticity of the Fix-Safe seal combined with its unique design ensures optimum sealing performance.
• The system can sustain an average of 20-35 kW for condensing (HE) boilers and 24-42 kW for non-condensing (SE) boilers.
• CFSeo-FA system is supplied as a complete kit of parts to build the complete assembly installation comprising:
• Trega® terminal with storm collar • tile with lead flashing or flat flashing • single pipe T-pieces with appropriate number of connections per storey, • single pipe parallel sections, • condensate collector base unit, • floor brackets and floor supports.• As an aid to section assembly we recommend applying soapy film
to the joint seal surfaces prior to push fit connection (obtainable from Cox Geelen).
CFSeo-FA
PIPE DIAMETER IN RELATION WITH THE NUMBER OF APPLIANCES
H FLOOR L
2700 MM 1300 MM
2750 MM 1350 MM
2800 MM 1400 MM
2850 MM 1450 MM
2900 MM 1500 MM
2950 MM 1550 MM
For other CFSeo-FA parts, please refer to the CFS-NV section in this brochure.
For > 20 appliances, the applicable pipe diameters are available on request.
Cox Geelen
Emmastraat 92 • 6245 HZ Eijsden • PO-Box 6 • 6245 ZG Eijsden • The NetherlandsT +31 (0)43 40 99 500 • F +31 (0)43 40 91 987 • sales@coxgeelen.com • www.coxgeelen.comChamber of Commerce Zuid-Limburg 14608324
Member of Bergschenhoek Groep
CFS-NV CFS-FA
A complete communal flue system, providing air supply to and exhaust gas and condensate removal from, multiple heating and hot water gas fired appliance installations via concentric pipes, all operating under a fully naturally vented negative pressure.CFS-NV is Cox Geelens complete flue system which combines a communal air supply and a communal flue outlet for use with gas fired condensing (HE) and non condensing (SE) boilers. The system operates with negative pressure and fits perfectly with the latest generation gas fired heating appliances, with flue/air connection Ø 80/80, 60/100 and 80/125 mm. The system conforms to the rigorous ‘Gaskeur’ Test no 138 and is certified by Gastec Qa, cert. no- 96/006 01, report no 175466. It is also CE Marked in accordance with European Standards EN 1856-1.
Special features:
• The outer aluminium pipe has a fully welded longitudinal seam and is roll grooved for maximum rigidity. The CoxSafe seal applied to the male o/d circumference ensures an airtight male/female joint at installation assembly.
• The aluminium inner pipe has a 1.5mm wall thickness, has a longitudinal TIG-welded seam with its female end fitted with the latest Fix-Safe seal(FS) for a gas-tight and condensate-tight push fit joint.
• The elasticity of the Fix-Safe seal combined with its unique design ensures optimum sealing performance.
• The system can sustain an average of 20-35 kW for condensing (HE) boilers and 24-42 kW for non-condensing (SE) boilers.
• Each CFS-NV system is supplied as a complete kit of parts to build the complete assembly installation comprising:
• roof terminal, • roof mounting plate or flat flashing with storm collar, • concentric T-pieces with appropriate number of connections per storey, • concentric twin sections, • condensate collector base unit, • floor brackets and • floor supports.• As an aid to section assembly we recommend applying soapy
film to the joint seal surfaces prior to push fit connection (obtainable from Cox Geelen).
1
2
4
6
5
4
6
7
3
RooF MoUnTinG pLaTe
FLooR
D1 D2 D4 0 M L H MIN
140 280 400 220 315 200 1035
160 315 450 248 315 225 1088
180 355 507 279 315 254 1148
200 400 570 314 315 286 1215
225 450 643 353 315 321 1289
250 500 714 393 315 357 1365
280 560 800 440 315 400 1455
315 630 900 495 315 450 1560
355 710 1014 558 315 507 1680
400 800 1143 628 315 571 1814
D1 / D2 20 kW HE24 kW SE
25 kW HE30 kW SE
30 kW HE36 kW SE
35 kW HE42 kW SE
140/280 2 2
160/315 3/4/5 3 2
180/355 6/7 4/5 3/4 2/3
200/400 8/9/10 6/7 5/6 4/5
225/450 11/12/13 8/9/10 7/8 6/7
250/500 14/15/16 11/12/13 9/10/11 8/9
280/560 17/18/19/20 14/15/16 12/13/14 10/11/12
315/630 17/18/19/20 15/16/17 13/14/15
355/710 18/19/20 16/17/18
400/800 19/20
T-piece 2 connecTions
T-piece 1 connecTion
deTaiL connecTion (WiTH GUide pLaTe)Ø 80/80
T-piece 1 connecTionØ 60/100 Ø 80/125
• Fix the height from the roof top till the middle of the last T-piece
FLAT ROOF
• Fix the right roof angle
SLOPING ROOF
A complete communal flue system, providing air supply to and exhaust gas and condensate removal from, multiple heating and hot water gas fired appliance installations via concentric pipes. Fan assisted, positive pressure operation allows the system to become more space saving for an extra compact installation.CFS-FA is Cox Geelens complete flue system which combines a communal air supply and a communal flue outlet for use with gas fired condensing (HE) and non condensing (SE) boilers with flue/air connection Ø 80/80, 60/100 and 80/125 mm, that are fitted with non-return valves. The system operates with positive pressure and the non-return valve arrangement on each boiler connection is essential to prevent recirculation of exhaust gases to non operational appliances. This system is also CE Marked in accordance with European Standards EN 1856-1 .
Special features:
• The outer aluminium pipe has a fully welded longitudinal seam and is roll grooved for maximum rigidity. The CoxSafe seal applied to the male o/d circumference ensures an airtight male/female joint at installation assembly.
• The aluminium inner pipe has a 1.5 mm wall thickness, has a longitudinal TIG-welded seam with its female end fitted with the latest Fix-Safe seal (FS) for a gas-tight and condensate-tight push fit joint.
• The elasticity of the Fix-Safe seal combined with its unique design ensures optimum sealing performance.
• Each CFS-FA system is supplied as a complete kit of parts to build the complete assembly installation comprising:
• roof terminal with storm collar, • tile with lead flashing or flat flashing, • concentric T-piece with appropriate number of connections per storey, • concentric twin sections, • condensate collector base unit, • floor brackets and floor supports.• As an aid to section assembly we recommend applying soapy film
to the joint seal surfaces prior to push fit connection (obtainable from Cox Geelen).
condensaTe coLLecToR deTaiL connecTion base UniT (WiTHoUT GUide pLaTe)
FiX - saFe
CFS-NV
PIPE DIAMETER IN RELATION WITH THE NUMBER OF APPLIANCES
FiX - saFe
T-piece WiTH1-2-3-4 connecTions
T-piece 2 connecTions
FLooR bRackeT
deTaiL asseMbLy oF FLUe/aiRpipe and T-piece
Concentric diameter data is specific to the number of appliances connected and is available upon request. For other CFS-FA parts, please refer to the CFS-NV section in this brochure.
RooF TeRMinaL
sToRM coLLaR
FLooR bRackeT
T-piece
FLUe and aiR pipe
FLooR bRackeT
T-piece
condensaTe coLLecToR base UniTWiTH adJUsTabLe FLooR sUppoRT
RooF TeRMinaL
FLUe and aiR pipe
T-piece 1 connecTion
condensaTe coLLecToR base UniTWiTH adJUsTabLe FLooR sUppoRT
H FLOOR L
2700 MM 1300 MM
2750 MM 1350 MM
2800 MM 1400 MM
2850 MM 1450 MM
2900 MM 1500 MM
2950 MM 1550 MM