cbx daisy chain configuration ! failure to...

Post on 09-Jan-2020

11 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

FINAL STEP 6. CLOSE BOX

STEP 5. OUTPUT TO FIXTURE

STEP 1. INSTALL HOUSING STEP 2. OPEN BOX

p.1/2

CBX DAISY CHAIN CONFIGURATIONDMX/RDM & ETHERNET

2X

CONNECTION STEPS

CBX-DS ™

Bottom half of CBX housing shown

100-277V &DATAOUTPUT TOFIXTURE(TYPICAL 5CONDUCTORCABLE)

DATA OUT -

100-277V INPUT

SUITABLE STRAIN RELIEFDEVICE TO BEPROVIDED BY INSTALLINGCONTRACTOR.

LIVE (BLACK)NEUTRAL (WHITE)GROUND (GREEN)

GROUND (GREEN)

DATAINPUT DATA IN +

DATA IN-

DATA OUT +

LIVE (BLACK)NEUTRAL (WHITE)

OUT -1

DATAINPUT

100-277V & DATAOUTPUT TO FIXTURE(TYPICAL 5 CONDUCTOR CABLE)(MAXIMUM OF (4X) CASCADINGCONTROL BOXES PER INSTALLATION,ISOLATED)

100-277V INPUTOPTIONAL DATA

OUTPUT TO NEXT CBX(NOT ISOLATED/NOT BOOSTED)

DATA OUT -

GROUND (GREEN)DATA OUT +

DATA IN -DATA IN +

LIVE (BLACK)NEUTRAL (WHITE)

GROUND (GREEN)

LIVE (BLACK)NEUTRAL (WHITE)

2X

MOUNTING HOLES ON THE BOTTOM OF THE CBX

4X

STEP 4. DATA INPUT (ETHERNET CONTROL OPTION)

USE 1/4”-20 UNC OR M6 ANCHORING BOLTS THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE (PROVIDED BY INSTALLING CONTRACTOR)

[160mm]166 5 "

5 516

"

[135mm]

INSTALL HOUSING WITH COVER FACING

UP WHEN OPEN

NOTICE

KEEP 5" [127mm] CLEARANCE ON ALL SIDES

NOTICE

USE A 5/16" [8mm] STRIP LENGTH FOR CONNECTIONSNOTICE

[8mm]165 "

5"[127mm]

IF INPUT IS ETHERNET, CONNECT CABLE DIRECTLY TO RJ45 PORT ON CONTROL CARD AND PROCEED TO THE NEXT STEP.

AS DELIVERED

CAUTION

WARNING!

DO NOT EXCEED CONTROLSPECIFIED VOLTAGE.

WARNING!

DO NOT USE IF PARTS ORCONNECTORS ARE DAMAGED.

WARNING!

CAUTION

American Color CodeWIRE COLOR / USE

GREEN GROUNDWHITE NEUTRALBLACK LIVE 100-277VRED or PURPLE DATA +ORANGE DATA -

CE Color CodeWIRE COLOR / USE

YELLOW/GREEN GROUNDBLUE NEUTRALBROWN LIVE 220/240VBLACK DATA +GREY DATA -

American Color Code Shown

CONSULT BLOCK CONNECTORMARKINGS FOR APPROPRIATE USAGE

POWER INPUT/DATA OUTPUT:RECOMMENDED WIRE GAUGE: 16 AWG [1.307mm²]

RANGE: 20-12 AWG [0.519-3.301mm²]

DATA INPUT:WIRE GAUGE RANGE: 24-16 AWG [0.205-1.307mm²]

NOTICEWARNING!

SEPARATION OF FIELD INSTALLED POWER LIMITED CIRCUIT (DIMMING/CONTROL) WIRING FROM THE BRANCH CIRCUIT

WIRING IN THE OUTLET BOX ARE TO BE MADE IN ACCORDANCE WITH LOCAL

AND/OR NATIONAL ELECTRICAL INSTALLATION CODES.

DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO

AVOID ELECTRICAL SHOCK.

UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY.

THE USE OF RTV SILICONE IS RECOMMENDED TO SEAL ALL

ENTRY POINTS (PRESSURE GLANDS, CONDUIT). THIS WILL ENSURE THE

ASSEMBLY IS WATERTIGHT.

PROVIDED TOOL:FLAT SCREWDRIVER

(FOR BLOCK CONNECTOR WIRING)

REQUIRED TOOL:#3 PHILLIPS

SCREWDRIVER

DMX/Data Cable SpecificationDMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for

Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.

Combined Power & Data Cable SpecificationFixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a

minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.

STEP 3. 100-277V INPUTLOCKING CONNECTION

STEP 4. DATA INPUT (DMX/RDM CONTROL OPTION)PUSH IN CONNECTION LOCKING CONNECTION

SHIFT THE TERMINATION SWITCH TO THE "ON"

POSITION TO TERMINATE THE LAST CBX IN THE DAISY

CHAIN.

FOR ALL OTHER CBX IN THE RUN SHIFT THE TERMINATION

SWITCH TO THE "OFF" POSITION.

NOTICE

OFF

ON

100-277V

drawing number 121846

INSTALLATION INSTRUCTIONS

2016.07.28NK - R5

Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289info@lumenpulse.com www.lumenpulse.com

Copyright © Lumenpulse 2016

Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.

This product must be installed in accordance with applicable national and local electrical and constructioncodes by a person familiar with the construction and operation of the product and the hazards involved.

Failure to comply with the following installation instructions may result in death or serious injury. !

OUT -1

p.2/2

CBX DAISY CHAIN CONFIGURATIONDMX/RDM & ETHERNET

CBX-DS ™

FINAL STEP 6. CLOSE BOX

STEP 3. 347V INPUT STEP 4. DATA INPUT (DMX/RDM CONTROL OPTION)

STEP 4. DATA INPUT (ETHERNET CONTROL OPTION)

STEP 5. OUTPUT TO FIXTURE

2X

CONNECTION STEPS

Bottom half of CBX housing shown

347V & DATAOUTPUT TO FIXTURE(TYPICAL 5 CONDUCTOR CABLE)

IF INPUT IS ETHERNET, CONNECT CABLE DIRECTLY TO RJ45 PORT ON CONTROL CARD

AND PROCEED TO THE NEXT STEP.

STEP 1. INSTALL HOUSING STEP 2. OPEN BOX

2X

MOUNTING HOLES ON THE BOTTOM OF THE CBX

4X

PROVIDED TOOL:FLAT SCREWDRIVER

(FOR BLOCK CONNECTOR WIRING)

REQUIRED TOOL:#3 PHILLIPS

SCREWDRIVER

USE 1/4”-20 UNC OR M6 ANCHORING BOLTS THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE (PROVIDED BY INSTALLING CONTRACTOR)

[162mm]6 3

8 "

10 38 "

[264mm]

USE A 5/16" [8mm] STRIP LENGTH FOR CONNECTIONS

NOTICE

SHIFT THE TERMINATION SWITCH TO THE "ON"

POSITION TO TERMINATE THE LAST CBX IN THE DAISY

CHAIN.

FOR ALL OTHER CBX IN THE RUN SHIFT THE TERMINATION

SWITCH TO THE "OFF" POSITION.

NOTICE

[8mm]165 "

5"[127mm]

AS DELIVERED

CAUTION

WARNING!

DO NOT EXCEED CONTROLSPECIFIED VOLTAGE.

WARNING!

DO NOT USE IF PARTS ORCONNECTORS ARE DAMAGED.

WARNING!

CAUTION

American Color CodeWIRE COLOR / USE

GREEN GROUNDWHITE NEUTRALBLACK LIVE 347VRED or PURPLE DATA +ORANGE DATA -

CONSULT BLOCK CONNECTORMARKINGS FOR APPROPRIATE USAGE

POWER INPUT/DATA OUTPUT:RECOMMENDED WIRE GAUGE: 16 AWG [1.307mm²]

RANGE: 20-12 AWG [0.519-3.301mm²]

DATA INPUT:WIRE GAUGE RANGE: 24-16 AWG [0.205-1.307mm²]

NOTICE

WARNING!

SEPARATION OF FIELD INSTALLED POWER LIMITED CIRCUIT (DIMMING/CONTROL) WIRING FROM THE BRANCH CIRCUIT

WIRING IN THE OUTLET BOX ARE TO BE MADE IN ACCORDANCE WITH LOCAL

AND/OR NATIONAL ELECTRICAL INSTALLATION CODES.

DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO

AVOID ELECTRICAL SHOCK.

UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY.

THE USE OF RTV SILICONE IS RECOMMENDED TO SEAL ALL

ENTRY POINTS (PRESSURE GLANDS, CONDUIT). THIS WILL ENSURE THE

ASSEMBLY IS WATERTIGHT.

DMX/Data Cable SpecificationDMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for

Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance.

Combined Power & Data Cable SpecificationFixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a

minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.

LOCKING CONNECTION PUSH IN CONNECTION LOCKING CONNECTION

347V & DATAOUTPUT TO FIXTURE(TYPICAL 5 CONDUCTOR CABLE)(MAXIMUM OF (4X) CASCADINGCONTROL BOXES PER INSTALLATION, ISOLATED)

DATA INPUT

OPTIONAL DATAOUTPUT TO NEXT CBX

(NOT ISOLATED/NOT BOOSTED)

347VINPUT

DATA OUT -DATA OUT +

DATA IN +DATA IN -

DATA OUT +DATA OUT -

NEUTRAL (WHITE)GROUND (GREEN)

LIVE (BLACK)

NEUTRAL (WHITE)LIVE (BLACK)

GROUND (GREEN)

SUITABLE STRAIN RELIEFDEVICE TO BE PROVIDED

BY INSTALLING CONTRACTOR.

347VINPUT

LIVE (BLACK)GROUND (GREEN)

NEUTRAL (WHITE)

TERMINATIONSWITCH

DATA OUT +DATA OUT -

NEUTRAL (WHITE)GROUND (GREEN)

LIVE (BLACK)

DATA INPUT

DATA IN +DATA IN -

OFF

ON

KEEP 5" [127mm] CLEARANCE ON ALL SIDES

NOTICE

INSTALL HOUSING WITH COVER FACING

UP WHEN OPEN

NOTICE

347V

drawing number 121846

INSTALLATION INSTRUCTIONS

2016.07.28NK - R5

Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289info@lumenpulse.com www.lumenpulse.com

Copyright © Lumenpulse 2016

Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.

This product must be installed in accordance with applicable national and local electrical and constructioncodes by a person familiar with the construction and operation of the product and the hazards involved.

Failure to comply with the following installation instructions may result in death or serious injury. !

top related