DESCRIPTION

Presentation covers how to reduce outside air requirements by using bi-polar ionization and air purification devices.

TRANSCRIPT

Global Plasma SolutionsEngineering Air for a Better World©

Data Presented is the Property of GPS, LLC

Commercial Applications

• Education• Hospitality• Worship• Veterinary• Sports Arenas• Restaurants

OA Reduction• Waiting Areas• Patient Rooms• Burn Center• Cancer Center• TB Isolation• DOD / State Dept.

Critical Environment

Pathogen Control in the Space!

GPS’ ASHRAE BASED IAQ Software1. Calculates Ventilation Rate Based on VRP

2. Simultaneously Calculates OA Based on IAQ Procedure with NO Extra Time Required!

3. Consultants Can Add Extra Value to Owner

4. Reduces Engineering Labor

5. Lowers First Costs, Operating Costs and Provides Better IAQ

6. Easy to Use

• IMC 2006 & 2009 includes a provision for engineered ventilation systems– Section 403.2 – Exception

ICC / IMC

Does It Really Work?

• 3rd Party Testing On Previous Installations Prove Compliance Using GPS’ Technology

– Holy Trinity Catholic School, Bay St. Louis, MS» Testing Provided by Green Clean Air, Reston, VA

– Roanoke, VA Office Space» Testing Provided by Air Advice

– Annistown ES – Coming Soon» Testing will be provided by Bureau VERITAS» Brad Gilber

UL 867 GPS-RN tested by Intertek/ETL to prove compliance to UL 867.

UL 867 Section 37.2.1. "The test is to be conducted in a chamber having a volume of 950-1100 cubic feet with a minimum side dimension of 8 feet and a maximum height dimension of 10 feet..."

New UL 867 as of December 21, 2007 requires ozone peak and chamber testing

GPS results: Peak Ozone: 0.0042 PPM @ 2.0 inches from needlesChamber: 0.007 PPM (24 hour test)

Max Allowed Limit: 0.05 PPM

GPS is 1/7 of the allowable limit!

This is specifiable and all manufactures should comply!

Independent Testing on a 2,400 sqft Office

3765 ug/m3 Initial Chemical Level

Final Chemical Level 231 ug/m3

OA Does Not Control IAQ Alone!

0.0

5.0

10.0

15.0

20.0

0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6

Conc

entr

ation

(mg/

cu.m

)

Ventilation Rate (AC/Hr)

Ventilation for VOC Control

VOC

Source:National Institute of Standards & Technology

USA Today Website

July, 2010 Issue of HVAC Insider Magazine

Article Author: Bruce Longino, P.E., LEED AP

Topic: Reduction of Outside Air Using ASHRAE 62 IAQ Procedure and Needlepoint Bi-Polar Ionization

Ventilation Rate Procedure w/o ERU

Typical Classroom w/30 People

IAQ Procedure without Energy Recovery

Typical Classroom w/30 PeopleWall Unit w/GPS

Ventilation Rate Procedure with ERU

Typical Classroom w/30 People

IAQ Procedure with Energy Recovery

Typical Classroom w/30 PeopleWall Unit w/GPS

The Big Picture w/ OA Reduction

Smaller OA Unit Or Elimination of OA UnitDownsize OA DuctDownsize Electrical

Downsize Structural SteelPumps, Valves, Piping - All Reduced

Many Building Trades Affected!

The Big Picture w/ OA ReductionAtlanta Area Schools (120,000 ft²)

Typical First Cost Savings = $300,000 to $400,000or $2.50/ft²

Typical Annual Energy Savings = $48,000 or $0.40/ft²

GPS Adds VALUE Not Cost!

H

H

H

N

H +

H +

H +

N+

Ammonia Molecule

Plasma Field

Plasma Breaks Down Gases To Less Objectionable Forms

H H

H

N

O O

O

O

O

O

O

H

N

N

O

O

O

H

H

O

O

O

Oxygen

N N

N

Nitrogen

Water Vapor

The Objectionable Gases Regroup To Form Safe & Desirable Gases Already Prevalent in Our Atmosphere!

Chemical Compounds Plasma Can Easily Control

CHEMICAL FORMULA Electron Volt

Xylene C8H10 7.89

Styrene C8H8 8.46

Methyl Ethyl Ketone C3H8O 9.52

Ammonia NH3 10.07

Acetaldehyde CH3CHO 10.23

Ethyl Alcohol C2H5OH 10.48

Formaldehyde CH2O 10.88

Oxygen O2 12.07

Methane CH4 12.61

0

200

400

600

800

1000

1200

1400

1600

Office Ventilated Cities Cities Rural Mountain GPS Space

Buildings Buildings (Large) (Small) Areas Air Design

Ions / cm3

Ion Counts at Various Locations

Positive

Negative

Contaminant

+

+ +

+

Mold, Virus & Bacteria ControlThe Positive and Negative Ions Attack DNA Cell Structure

& Removes Hydrogen

+

Plasma

Source

New Plasma TV Old Tube TV

New PlasmaIon

Generators

Old Plasma IonGenerators

GPS-IN

Nominal Capacity ≈ 1,200 CFM

Casing – ABS Plastic

Voltage – 12VDC Input

Indoor Mounted

Mount with Velcro or Metal Strap

GPS-RN

Nominal Capacity ≈ 2,400 CFM

Casing – Stainless Steel5.0”L x 3.8”W x 2.0”D

Voltage – 12VDC input

Indoor Mounted

Stainless Steel Needles

AirflowDirection

GPS Power & Mounting Options24VAC (GPS-P2412) (comes with PC1)

100VAC to 240VAC (GPS-UP12) (Water Proof & comes with PC1)

100VAC to 240VAC (GPS-UP13) (PC1)

85VAC to 266VAC (GPS-UPW12)

4X Enclosure (GPS-RN-4X) (Outdoor Duct)115VAC Receptacle Inside 4X box w/GPS-RN (GPS-RN-4XR)

Powers (3) GPS-RN or (20) GPS-IN

Powers (3) GPS-RN or (20) GPS-IN

Powers (2) GPS-RN or (15) GPS-IN

Powers (2) GPS-RN or (15) GPS-IN

GPS-BP120 (includes j-box, rec & ps)GPS-BPJB (includes j-box & cover – ps extra)

GPS-BP (no j-box or power supply)

GPS-BP120 Bottom View

GPS-NEXT

Extends Needles 2-3 Inches

Plasma Pole

Nominal Capacity ≈ No Limit

Casing – Stainless Steel

Voltage – 12VDC input

Indoor Mounted

Stainless Steel NeedlesContractor Provides Uni-strut or Angle Based on the Application, i.e., RTU, AHU, etc.

PC2

Benefits of GPS’ PlasmaLower First Cost

Increased Energy SavingsNo Replacement Tubes Required

Improved IAQMold, Bacteria & Virus Control

Static Electricity ControlOdor Control

Reduced AllergensCompact and Fits Every Application

Essentially No Maintenance

Custom AHU Layout

GPS-RN GPS’ PLASMA REPLACED CARBON & UVCLEED POINTS MAY BE ACHIEVED

GPS-600

Nominal Capacity ≈ 400 CFM

Floor Mounted – ABS Plastic Cover and Galvanized Steel Interior Prefilter, carbon, TiO2, UVC, Ionization, 99.97 HEPA & Fan

Voltage –115VAC 60Hz 150W

68”H x 19.4”W x 11.6”D

GPS-300

Nominal Capacity ≈ 300 CFM

Ceiling Mounted – ABS Plastic Cover and Galvanized Steel Interior Prefilter, carbon, TiO2, UVC, Ionization, 99.97% HEPA & Fan

Voltage –115VAC 60Hz

24”W x 24”L x 18”D

Side Access Housings + AHU’sIndoor / Outdoor ConstructionGalv., Alum, SS

Single / Double WallParticulate – HEPA Filters

Carbon Trays

UVC

Bi-polar Ionization

Fan / VFD

Custom AHU – Bag In/Out Housing

Combustion Reduction Technology

Ice Resurfacing Equipment, Forklifts, etc.

LPG & NG Catalysts:Catalytic Mufflers for Spark-Ignited Engines

“Cold Start” Diesel Catalysts:Catalytic Converters for Diesel Engines

Diesel Particulate Filters

Generators, Construction Equipment and Mining Equipment

Generators, Construction Equipment and Mining Equipment

Global Plasma SolutionsEngineering Air for a Better World©

We appreciate the opportunity to present our products!

top related