Radiant Vision Systems | A Konica Minolta CompanyRadiant Vision Systems | A Konica Minolta Company

System Benefits for SAE-Standard Optical Performance Evaluation of HUDs

AUTOMATED HEAD-UP DISPLAY MEASUREMENT

2Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

TODAY’S TOPICS

• SAE Standards for Head-Up Displays

• SAE J1757-2

• Measurement Requirements

• Technology to Enable Automation:

• Electronically Controlled Lens

• Modulation Transfer Function (MTF)

• Full Field-of-View Imaging

• Multi-Test Sequencing Software

• Software Tests: TT-HUD Module

3Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

2 – 43 MP Sensor / Cooled / Temp. Stabilized

CIE Matched Color Filters

Electronic ND Filter Selection (colorimeter)

Electronic Lenses

On-Camera Calibration Data

USB & Ethernet Control

On-camera Touch Control (colorimeter)

• Auto-Lens Recognition• Electronic Zoom control• Electronic Aperture

selection• Auto-selection of

Calibration Data

IMAGING COLORIMETERS/PHOTOMETERS

4Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

SAE STANDARD HUD MEASUREMENTBACKGROUND AND REQUIREMENTS

5Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

HUD MEASUREMENT STANDARDS

Radiant has worked with

SAE Committee to define

new HUD Standard

▪ SAE J1757-2

▪ “Optical System HUD for

Automotive”

▪ Imaging photometers

implemented into the

standard as a primary

solution for HUD testing

6Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

REQUIREMENTS FOR SAE STANDARD MEASUREMENT DEVICES

Optical meter camera

▪ Measure luminance, chromaticity, uniformity

▪ NIST-traceable

▪ Example: Photometer

Distance meter

▪ Measure geometrical distance, direction, angle, distortion

▪ Example: Smart Camera

7Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

KEY HUD MEASUREMENT CHALLENGES

• Virtual image location and size

• Image resolution and contrast accuracy

• Number of tests and parameters per test image

• Enabling production-level automated measurement

8Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

USING AN ELECTRONICALLY CONTROLLED LENSGAUGING VIRTUAL IMAGE SIZE AND LOCATION

9Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

Is the virtual image projected at the right location and at the correct size?

HUD

LOOK DOWN ANGLE ()

PROJECTION DISTANCE

SIZE

VIRTUAL IMAGE

10Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

VIRTUAL IMAGE

PROJECTION DISTANCE = FOCAL DISTANCE

DEPTH OF FOCUS (DOF)

• Convert focal distance to “real distance” units

• Using focal distance, and virtual image size, the distance of the projected image can be output automatically by software

MEASURING PROJECTION DISTANCE

11Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

OPTIMIZING FOCUS

12Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

OPTIMIZING FOCUS

Out of Focus Better Focus Best Focus

Notice: Increasing slope on cross section plot (corresponding to decreasing blue region

(between 10% and 90% of max grey value). Increasing focus bar (orange)

13Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

Calibrated cameras

provide absolute distance

measurements

Electronically controlled

lenses determine

projected image plane

▪ Remove human

calculation, error

▪ Reduce time to set up

measurements

CALCULATING ABSOLUTE MEASUREMENTS

f1

f2

14Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

Calibrated cameras

provide absolute distance

measurements

Electronically controlled

lenses determine

projected image plane

▪ Remove human

calculation, error

▪ Reduce time to set up

measurements

CALCULATING ABSOLUTE MEASUREMENTS

15Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

DEPTH OF FOCUS

16Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

MODULATION TRANSFER FUNCTION (MTF)QUANTIFYING MODULATION FOR RESOLUTION AND CONTRAST OF PROJECTIONS

17Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

HUD PROJECTOR (DLP) STRUCTURE

HUD

VIRTUAL IMAGE

CAMERA IN THE “EYE BOX”

DLP STRUCTURE

HUD Optics

DLP Optics

DM

D

HUD Electronics

Source Image

Projected Image

Picture Generating Unit (PGU)

HUD Box

18Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

PRESERVING IMAGE CLARITY

DMD

Micro-mirror array

19Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

TESTING FOR MODULATION

Modulation = value that describes resolution + contrast

Modulation Transfer Function (MTF) determines the level of spatial frequency between contrasting areas

Testing is done using projections of horizontal and vertical pairs of black and white lines

20Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

LINE-PAIR ALGORITHM

Line-pair algorithms quickly measure modulation between vertical and horizontal line pairs

21Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

FULL FIELD-OF-VIEW IMAGINGCAPTURING AND QUANTIFYING MULTIPLE DATA POINTS

22Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

REDUCE SETUP & MEASUREMENT TIME

Spot-based measurement requires multiple test points

Image-based measurement captures all data at once

23Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

ACCOMPLISH MULTIPLE MEASUREMENTS AT ONCE

Required measurements for SAE J1757-1:

▪ Uniformity

▪ Contrast

▪ Pixel count resolution

▪ Location / Size

▪ Ghosting

▪ Distortion / Alignment

▪ Modulation Transfer Function (MTF) Measurement sequences performed on a single

image by software paired with imaging solution

24Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

OBTAIN DATA BASED ON CONTEXT

25Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

INTRA-CHARACTER UNIFORMITY

Spot meter takes single-spot measurements at defined points.

Imaging enables software to measure entire symbol at once.

26Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

• Quickly determine, Lv; x,y; u’,v’; pixel count; and much more.

• Run specific user-based pass/fail criteria against each analysis requirement

INTER-CHARACTER UNIFORMITY

27Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

PIXEL RESOLUTION OF SYMBOLS

28Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

CONTRAST

29Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

GHOSTING

30Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

DISTORTION

31Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

TESTING FOR GHOSTING & DISTORTION

Test Pattern Measurement Image

32Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

MULTI-TEST SEQUENCING SOFTWAREAUTOMATING TEST AND MEASUREMENT

33Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

PRODUCTION-LEVEL MEASUREMENT

34Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

SOFTWARE TEST SEQUENCING

35Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

FULL SET OF TESTS INCLUDED IN TT-HUD™

36Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

EXAMPLE SEQUENCE FROM TT-HUD

37Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

ANSI BRIGHTNESS

The ANSI Brightness test averages the measured brightness of an image at the ANSI-9 points and compares these values against various Pass/Fail criteria.

38Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

UNIFORMITY

The Uniformity test Creates NxN grid on image, and reports out average luminance of each grid point, as well as additional statistics (min, max, difference)

39Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

SEQUENTIAL CONTRAST

The Sequential Contrast Analysis takes measurement of Black and White patterns. Compares luminance values within defined region. Computes contrast ratio.

40Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

EYEBOX TEST: OVERVIEW

Pass/Fail Parameters:- Min Contour Width (sensor pixels)

- If the width of the Contour (box around the edge of the target) is below this value, the test fails. The test also fails if there is a break anywhere in the contour.

The Eyebox test uses a target with a black background and a white, continuous line around the edge, and an optional cross in the middle

The analysis evaluates if this contour is unbroken. This tells the user that the entire eyebox is visible from that location of the Photometer or Colorimeter

41Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

EYEBOX TEST: PASS

42Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

EYEBOX TEST: FAIL (BROKEN)

43Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

EYEBOX TEST: FAIL (MISSING SIDE)

44Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

DISTORTION DOT GRIDThe Distortion Dot Grid analysis finds and reports out the position of each grid point.

Pass/Fail Criteria:- Total number of dots- Min Row Spacing- Max Row Spacing- Min Column Spacing- Max Column Spacing

45Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

DISTORTION LINE GRID

The Distortion Line Grid analysis finds the points where lines of a test image intersect and reports their location.

Pass/Fail Criteria:- Total number of dots- Min Row Spacing- Max Row Spacing- Min Column Spacing- Max Column Spacing

46Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

WARPING

The Warping Test Image has an array of evenly spaced dots. The analysis locates these white dots and reports their distance the center dot.

No Pass/Fail Criteria

47Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

GHOSTING: OVERVIEW

The Ghosting Analysis measures the Ghosting Target (white dots on a black background)

The analysis finds the location of the original dot (parent) and the location of the corresponding ghost and reports the distance. This analysis can currently analyze images with ONE ghost.

The ghost images can be connected to the original dot, or separated.

Pass/Fail Parameters:- Max distance (displacement) between

parent dot, and ghost

- Minimum Luminance Ratio ghost/parent

- Maximum Luminance Ratio ghost/parent

- Minimum number of displacement failures to report failure

48Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

GHOSTING: NO GHOST

Result: None Found

49Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

GHOSTING: SEPARATED GHOST

Reports out the luminance ratio (ghost/parent) and displacement distance between parent and Ghost image for each dot.

50Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

GHOSTING: CONNECTED GHOST

Reports out the luminance ratio (ghost/parent) and displacement distance between parent and Ghost image for each dot.

51Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

DIAGONAL CHECKERBOARD CONTRAST

The Diagonal Checkerboard Analysis places detectors on the black and white diamonds, reports the luminance values, calculates average black and white luminance, and reports ratio between the average black and white luminance.

Pass Fail Criteria:Minimum Contrast Ratio

52Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

MTF LINE PAIRS

The MTF Line Pairs test measures the MTF of the line pairs in the image, reporting out the contrast of each region. The regions can be user defined (as shown).

Pass/Fail Criteria:- Max Contrast Limit- Min Contrast Limit

53Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

ENABLING FULLY-AUTOMATED TESTING

HUD

VIRTUAL IMAGE

CAMERA IN THE “EYE BOX”

SERIES OF TEST IMAGESFOR EACH HUD TESTED

54Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

SUMMARY

✓ SAE J1757-2 standard specifies measurement devices for HUD evaluation

✓ HUD measurement can be most efficiently met using systems with:

✓ Electronically controlled lenses for simplified image location

✓ Built-in software algorithms for calculating Modulation Transfer Function (MTF) for visual image resolution and contrast

✓ Imaging capability and multi-test sequencing software for meeting the maximum measurement criteria at once

✓ Using these systems can enable fully-automated HUD measurement for application in production

55Radiant Vision Systems | A Konica Minolta Company

© Radiant Vision Systems, LLC.

Working closely with world class brands and manufacturers to deliver creative visual inspection solutions that improve

quality, reduce costs, and increase customer satisfaction.

Radiant Vision Systems | A Konica Minolta CompanyRadiant Vision Systems | A Konica Minolta CompanyQuestions? Contact Info@RadiantVS.com

THANK YOU!

top related