air conditioning system [50hz]file.enero.id/daikin_inverter_cac-70cc9-2724_126.pdf · daikin meets...
Post on 30-Apr-2020
3 Views
Preview:
TRANSCRIPT
PCSID1415A
AIR CONDITIONING SYSTEM [50Hz]
1
Daikin meets your needs with this full of indoor units and power supplies.
WALL MOUNTED TYPE
CEILING SUSPENDED TYPE
CEILING MOUNTED CASSETTE TYPE Round Flow
2
FLOOR STANDING TYPE
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
lineup of inverters for various types
3
RZR60LVVM4RZR50LVVM4FVQ60CVE4FVQ50CVE4
Outdoor unitIndoor unit
FLOOR STANDING TYPERZR60LVVM4RZR50LVVM4FBQ60DV14FBQ50DV14
Outdoor unitIndoor unit
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Outdoor unitIndoor unit
WALL MOUNTED TYPERZR60LVVM4RZR50LVVM4
FHQ60BVV1G4FHQ50BVV1G4RKS35AVMG4FHQ35BV1B4
Outdoor unitIndoor unit
CEILING SUSPENDED TYPE
RKS60AVMG4RKS50AVMG4RKS35AVMG4RKS25AVMG4Outdoor unit
OUTDOOR UNIT
60
RZR60LVVM4
50
RZR50LVVM4FCQ60LUV14FCQ50LUV14
3525
Outdoor unitIndoor unit
CEILING MOUNTED CASSETTE TYPE
Round Flow
Series
Pair
NEWNEW
RKS35AVMG4FFQ35BV1B4
RKS50AVMG4FFQ50BV1B4
RKS60AVMG4FFQ60BV1B4
RKS25AVMG4FFQ25BV1B4
Outdoor unitIndoor unit
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Outdoor unit
OUTDOOR UNIT
P r o d u c t L i n e u p
OUTDOOR UNIT
NEW RZR50LVVM4 NEW RZR60LVVM4
4
Page 19
Page 21
Page 17
Page 15
Page 13
Page 7
Page 11
RZR71LVVM4 RZR140LUY14RZR125LUY14RZR100LUY14FVQ140CVEB4FVQ125CVEB4FVQ100CVEB4FVQ71CVEB4
RZR71LVVM4 RZR140LUY14RZR125LUY14RZR100LUY14FBQ140DV14FBQ125DV14FBQ100DV14FBQ71DV14
RZR100LVVM4FAQ100CVEA4
RZR71LVVM4 RZR125LUY14RZR100LUY14FHQ125BV1B4FHQ100BV1B4FHQ71BV1B4
71 100 125 140
RZR71LVVM4 RZR140LUY14RZR125LUY14RZR100LUY14FCQ140LUV14FCQ125LUV14FCQ100LUV14FCQ71LUV14
NEW
RZR140LUY14RZR125LUY14RZR100LVVM4/RZR100LUY14NEW RZR71LVVM4
5
Achieved higher COPEnergy savingEnergy saving
New types of indoor unitsNew types of indoor units
COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher the energy efficiency, enabling cooling and heating with less electricity and increasing the energy saving performance.
Note : *Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24.0°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
What is COP (Coefficient of Performance)
COP
2
3
4
5
FCQ50LUV14RZR50LVVM4
Coo
ling*
FCQ140LUV14RZR140LUY14
2.85
Coo
ling*
FCQ125LUV14RZR125LUY14
3.40
Coo
ling*
FCQ100LUV14RZR100LUY14
3.60
Coo
ling*
FCQ71LUV14RZR71LVVM4
3.57
Coo
ling*
FCQ60LUV14RZR60LVVM4
4.87
4.30
Coo
ling*
CEILING MOUNTED CASSETTE TYPE
Round Flow
Floor standing type 5.0-14.0 kW class
Wall mounted type 10.0 kW class
NEW
NEW
Non-inverter
Inverter Time
Running current
Starting current
Time
Running current
Cur
rent
Cur
rent
At startup, full power is used to achieve the set temperature quickly. Then, the capacity is adjusted according to the outdoor temperature changes and subtle indoor load changes to achieve fine capacity control resulting in a more stable room temperature.Non-inverter type air conditioners must be switched on and off repeatedly, causing large fluctuations of the room temperature.
Inverter performs variable control of frequency, which determines air conditioner’s power performance.
Enhanced comfort with Inverter
Small temp. differenceCools a room
in less time
Cooling operation
Inverter power controlNon-inverter type air conditioner
Time
Temp
Set temp
ComfortableComfortableAt startup, inverter raises frequency smoothly, eliminating the starting current spike.
19 new combinations added!
Wider lineup of invertersWider lineup of invertersDaikin meets your needs with this full lineup of inverters for various types of indoor units and power supplies.
CEILING MOUNTED CASSETTE TYPE
Round Flow
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
WALL MOUNTED TYPE
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
FLOOR STANDING TYPE
Pair
503525 60 71 100 125 140
: New Lineup : Continuous
1 Phase
1 Phase
3 Phase
1 Phase
3 Phase
1 Phase
1 Phase
3 Phase
1 Phase
3 Phase
6
• • • • • *1 *2 • *2 • • • *2 • • • • • • • • • • *2
CleanlinessComfort Work & Servicing Control features OthersOptionsFeatures
Accessory required for indoor unit.Option
*1Applicable when wired remote controller is used*2For the outdoor units
*3Applicable when BRC1E62 is used*4Applicable when BRC1C61 is used
CEILING MOUNTED CASSETTE TYPE
FCQ50/60/71/100/125/140LU
Swin
g pa
ttern
sel
ectio
n
Switc
habl
e fa
n sp
eed
(2 s
tep)
Auto
sw
ing
Prog
ram
me
"Dry
"
Hig
h ce
iling
appl
icat
ion
Nig
ht q
uiet
ope
ratio
n
Dra
in p
ump
mec
hani
sm
•
Silv
er io
n an
ti-ba
cter
ial
drai
n pa
n
•
Anti-
bact
eria
l air
filte
r
Pre
char
ged
for
up to
30
m
Long
-life
filte
r
Filte
r sig
n
Cei
ling
soilin
g pr
even
tion
Low
gas
pre
ssur
e de
tect
ion
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Ultr
a lo
ng-li
fe fi
lter
•
Hig
h-ef
ficie
ncy
filte
r
Fres
h ai
r int
ake
kit
Con
trol b
y 2
rem
ote
cont
rolle
rs
Auto
-rest
art
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
•
DIII
-NET
com
mun
icat
ion
stan
dard
Anti
corro
sion
trea
ted
heat
exc
hang
ers
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Round Flow
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
BRC7F633F
A signal receiver must be added to the indoor unit.
Wireless remote controller and signal receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit (Installed type)
Note: Remote controller cable not included. Cables must be procured locally.
Note: Remote controller cable not included. Cables must be procured locally.
Wired LCD remote controller
BRC1C61
Remote controller
*3 *3 *3 *3 *4
Setp
oint
rang
e se
t
Wee
kly
sche
dule
tim
er
Setp
oint
aut
o re
set
Off
timer
(pro
gram
med
)
On/
Off
timer
Cassette air conditioner with 360° uniform airflow sets the standardCassette air conditioner with 360° uniform airflow sets the standard
7
8
Airflow distribution
Creates uniform comfort throughout
the space
Comfort enhanced by Round Flow!
With uniform temperature distribution
Enhanced Comfort
Greater comfortImproved energy saving
• Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.
Treated surface
Untreated surface
Grimy surface
Resists soiling
External panels are treated with a coating that repels dirt.
Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Avoids uneven temperature and discomfort caused by drafts.
To prevent dirt sticking to the external panels, they have been coated with a surface treatment.
Because air flows out from corner outlets, comfort spreads more widely.
360° airflow Air movement is gentle with Round Flow
Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean.
Non-flocking flapsSilver ion anti-bacterial drain pan
Prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters.
Filter has anti-mould and bactericidal treatment
Grime prevention and bactericidal coating: Make cleaning easier.
Adapts easily to the installation space.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.
3-way flow L-shaped 2-way flow
Opposite 2-way flow
(E.g., installed in a corner)
(E.g., installed in a long room)
(E.g., installed near a wall)
(E.g., installed in middle of ceiling)
4-way flow also possible.
All-round flow
360° airflow can maintain comfort even if air discharge speed is lower.
Typical flow patterns There are a total of 23 flow patterns.
If you raise the set temperature by 1 to 1.5°C,and velocity is decreased by 25%, you still obtain the same feeling temperature and comfort.
Operation sound increases when using 2-way or 3-way flow.
9
Quick and easy to installJust 256 mm high. Installable in tight ceiling spaces (50LU-71LU)
Fine square panels Compact body and quiet operation
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor.
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Note: Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller.
Panel size is same for all models, FCQ50-140LU.It is easy to maintain a neat appearance when multiple units are installed.
Optimal comfort and convenience assured by air discharge modes
Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.
Two selectable temperature-sensors
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.
Suitable for high ceilings
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
On/Off timer
Indoor unit High Low
125LU 44 34140LU 44 36
100LU 43 3271LU 35 2860LU 35 2850LU 35 28
dB(A)
Same for all models
Air direction
Auto air direction control
Settable to 5 different levels between 15° and 60°
Settable to 5 different levels between 25° and 60°
Auto-swing between15° and 60°
Auto-swing between25° and 60°
Recommended for shops with light coloured ceilings that
must be kept spotless.
Standard position to prevent draft.
Standard setting Setting to prevent soiling of ceiling*
The air direction is set automatically to the memorised position of the previous air direction.
Desired situation
Auto-swing
5-levelsair directionsetting
*Closing of the corner discharge outlets is recommended.
Number of air discharge outlets used
4-wayflow
3-wayflow
2-wayflow
4-wayflow
3-wayflow
2-wayflow
3.1 m3.4 m4.0 m
All round flow
2.7 m3.0 m3.5 m
3.0 m3.3 m3.5 m
3.5 m3.8 m-
3.4 m3.9 m4.5 m
All round flow
3.2 m3.6 m4.2 m
3.6 m4.0 m4.2 m
4.2 m4.2 m-
StandardCeiling height High ceiling
High ceiling
Criteria for ceiling height and number of air discharge outlets
950 mm 950 mm
Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting.
256 mm *1 266 mm *2
*1 298 mm high with 100LU–140LU*2 308 mm high with 100LU–140LU
All models can be installed without using lifter because of the light weight.
Connection to a centralised control system is available without option
Low gas pressure detection
Drain pump is equipped as standard accessory with 850 mm lift.
Transparent drain socket
Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height.
Since the orientation of the intake grill can be adjusted after installing,the direction of the intake grill lines can be unified when multiple unitsare installed.
Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets.
Easy height adjustment
Installable in any direction
Because the drain socket is transparent, after the drain piping has been installed, it is easy to check if the drain come out through the socket.High setting provides maximum reach while low
setting minimises drafts.
Switchable fan speed: High/Low
175 mm
850 mm
100LU–140LU50LU–71LU
CEILING MOUNTED CASSETTE TYPE Round Flow
(Ceiling height is reference value)
10
Options required for specific operating environments
High-efficiency filterAvailable in two types: 65% and 90% colorimetry.
Using this kit, a duct can be fitted to increase the intake of outdoor air.
*Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending.
Fresh air intake kit
Even in smoky environments where the air conditioning is on most of the time, the ultra long-life filter only has to be changed once a year.
Ultra long-life filter Panel spacerUse when only minimal space is available between drop ceilings and ceiling slabs.
Sealing material of air discharge outletSealing material block air discharge openings not used in 2-way or 3-way blow.
Branch duct (direct-connection round duct)
Outside
Note: Use of options will increase operating sound.
The units can be installed in the following different ways.
Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit.
Direct installation type
Flexible duct
T-joint pipe
Intake duct(procured locally)(duct length: 4 m max.)
Intake duct(procured locally)(duct length: 4 m max.)
Connectionchamber
Suctionchamber
Duct flange (with insulation material) Intake duct(procured locally)
Chamber type (with T-joint pipe and without fan)
Flexible duct(procured locally)
T-joint pipe(procured locally)
Chamber type (without T-joint pipe and fan)
KDDP55X160KDDP55B160K KDDP55B160
Easier to maintain
With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years.
The condition of the drain pan anddrain water can be checked byremoving the drain plug andintake grille. Drain plug
Just open the
intake grille!
40mm
Panel spacer
A round duct can be attached without the need for a chamber.A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole).
Connectionchamber
Suctionchamber
Smoky atmosphere: annual filter change
Ordinary store or office: filter change every 4 years
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.) 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years
Note:
11
Accessory required for indoor unit.Option
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable not included. Cables must be procured locally.
CleanlinessComfort Work & Servicing Control features OthersOption
Features
*1Applicable when wired remote controller is used*2Applicable when BRC1E62 is used*3Applicable when BRC1C61 is used*4 For the outdoor units
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Quiet decor-blending form and easy installation in new or old buildings.Quiet decor-blending form and easy installation in new or old buildings.
Swin
g pa
ttern
sel
ectio
n
Switc
habl
e fa
n sp
eed
(2 s
tep)
Auto
sw
ing
Prog
ram
me
"Dry
"
Dra
in p
ump
mec
hani
sm
Pre
char
ged
for
up to
10
m
Long
-life
filte
r
Filte
r sig
n
Self-
diag
nosi
s fu
nctio
n
Fres
h ai
r int
ake
kit
Con
trol b
y 2
rem
ote
cont
rolle
rs
Auto
-rest
art
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
Anti
corro
sion
trea
ted
heat
exc
hang
ers
Two
sele
ctab
le
tem
pera
ture
-sen
sors
• • • • *1 • *4 • •
Cei
ling
soilin
g pr
even
tion
• • • • • • • • • *4
BRC7E531WA signal receiver must be added to the indoor unit.
Wireless remote controller and signal receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit (Installed type)
Note: Remote controller cable not included. Cables must be procured locally.
Wired LCD remote controller
BRC1C61
•
Anti-
bact
eria
l air
filte
r
•
Mou
ld-p
roof
dra
in p
an
FFQ25/35/50/60B
Remote controller
*2 *2 *2 *2 *3
Setp
oint
rang
e se
t
Wee
kly
sche
dule
tim
er
Setp
oint
aut
o re
set
Off
timer
(pro
gram
med
)
On/
Off
timer
12
CompactSized to fit inside 600mm wide ceiling grids
Two selectable temperature-sensors
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor.
Designed for low draft performance
Consistent comfort throughout
Quiet operation has been achieved even with a compact body and developed spiral hub cover that reduces the static pressure inside the indoor unit.
Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer.
High setting provides maximum reach while low setting minimises drafts.Switchable fan speed: High/Low
Drain pump is equipped as standard accessory with 750 mm lift.
Comfortable
QuietQuiet, small-diameter fan
Multi-Flow System Air direction can be selected according to installation.
1 pattern
4-way flow
4 patterns
3-way flow
1 pattern
2-way flow
" " denotes piping direction. Drain piping " " denotes sealing member for air discharge outlet (option) .Note: For 3-way or 2-way flow installation, the sealing
member for air discharge outlet (option) must be used to close off the unused outlet(s).
Note: Operation sound increases when using 2-way or 3-way flow.
Spiral hub cover
750 mm
Settable to 5 different levels between 0° and 35°
Settable to 5 different levels between 0° and 60°
Settable to 5 different levels between 25° and 60°
Auto-swing between 0° and 35°
Auto-swing between 0° and 60°
Auto-swing between 25° and 60°
Draft prevention setting(Set on site)
(Set on site)
Standard setting
Setting to prevent soiling of ceiling
Auto-swing operation distributes conditioned air more evenly.
Airfow angle can be adjusted in accordance with room conditions.
Auto-swing
0° 0°
0°
25°
60° 60°
0°
35°
25°
60°
35°
60°
5-levels air direction setting
Horizontal flow0° 0°
Less draftcan be felt
575 mm
575 mm
700 mm
700 mm
286 mm
Fits without the need to cut T-bar grid
T bar
600 mm600 mm
Decoration
panel is also
compact.
Note: This angle above is provided as a guide. It may differ depending on the installation site.
Ceiling panel
The switch box is built in to the unit, so maintenance is possible by simply removing the grill. An inspection opening is not required even for modules other than 600 x 600.
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
dB(A)
Indoor unit25B 29.5 24.535B 32 2550B 36 2760B 41 32
High Low
13
Comfortable airflow travels throughout the roomComfortable airflow travels throughout the room
Accessory required for indoor unit.Option
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable not included. Cables must be procured locally.
Note: Remote controller cable not included. Cables must be procured locally.
Wired LCD remote controller
BRC1C61
A signal receiver must be added to the indoor unit. Wireless LCD remote controller
CEILING SUSPENDED TYPE
Wireless remote controller and signal receiver unit are sold as a set.
Signal receiver unit (Installed type)
BRC7EA66
CleanlinessComfort Work & Servicing Control features Others
Features
• • • *1 • *3 • • • • • • • *8*3*2 *6
*1Installable on max. 3.5 m high ceiling*2Applicable when wired remote controller is used*3Applicable to RZR outdoor units*4Applicable when BRC1E62 is used
*5Applicable when BRC1C61 is used*6Option*7Applicable to RKS outdoor units*8For the outdoor units
Pre
char
ged
for
up to
30
m
*7
Pre
char
ged
for
up to
10
m
•
Long
-life
filte
r
•
Anti-
bact
eria
l air
filte
r
Filte
r sig
n
*3
Low
gas
pre
ssur
e de
tect
ion
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Con
trol b
y 2
rem
ote
cont
rolle
rs
Auto
-rest
art
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Anti
corro
sion
trea
ted
heat
exc
hang
ers
Inte
rlock
con
trol
Dra
in p
ump
mec
hani
sm
Switc
habl
e fa
n sp
eed
(2 s
tep)
Auto
sw
ing
Prog
ram
me
"Dry
"
Hig
h ce
iling
appl
icat
ion
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Remote controller
*4 *4 *4 *4
Setp
oint
rang
e se
t
Wee
kly
sche
dule
tim
er
Setp
oint
aut
o re
set
*3
Nig
ht q
uiet
ope
ratio
n
Off
timer
(pro
gram
med
)
*5
On/
Off
timer
FHQ35/50/60/71/100/125BV
14
* For dust concentration of 0.15 mg/m3
50°
(mm)
Uses quiet stream fan and other quiet technologies.
Turbulent flow is reduced
Straightening plate
Quiet stream fan
50/60BVV1G4 39 35
Indoor unit High Low35BV1B4 37 32
71BV1B4 39 35100BV1B4 42 37125BV1B4 44 39
195
100BV1B4 125BV1B4
960 1,160 1,400 1,590680
Drain pump kit (built inside main unit)
Height
Indoor unit
WidthDepth
35BV1B4 50/60BVV1G471BV1B4
600 mm
Quiet operation
Easier to maintain
Sound operation has been reduced on the exposed ceiling suspended type unit.
Two selectable temperature-sensors
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor.
Oil resistant grilleOil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments.Note: Intended for use in salons, dining rooms, and ordinary sales
floors, this specification is not suitable for kitchens or other harsh environments.
For all maintenance tasks, access is from bottom surface.
Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).
It is easy to wipe dirt off the flat side and lower surfaces of the unit.
Easy-clean, flat surfaces
Long-life filter lasts about 1 year*
Diffuses comfortable air throughout the room
Auto-swing (up&down) brings comfort to the room.
Installation flexibility for freedom of design
Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer.
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Programme "Dry"
Wide air discharge openings produce a spreading 100° airflow
Air is blown up to 50° in the downward direction.
Switchable fan speed: High/Low
Installable on ceilings 3.5 m high
100°
Flexible installation
*Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case.
The unit fits more snugly into tight spaces.
Drain pump kit (option) can be easily incorporatedDrain pipe connection can be done inside the unit. refrigerant and drain pipe outlets are at the same opening.
Uniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints.
30 mm or more
30 mm or more
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
dB(A)
Pipes more easily riggedPlastic cover is used to conceal piping work holes.When piping work the cover is easily taken off, and after piping work easily attached again to conceal the holes.
Low gas pressure detection
All wiring and internal servicing can be done from under the unit
(Applicable to RZR outdoor units)
Non-flocking flap
Condensation does not easily form on and dirt does not cling to non-flocking flap. It is easy to clean.
Non-flocking flap
15
WALL MOUNTED TYPE
BRC1C61
Wired LCD remote controller
• • •• *4 • *3 • • • • • • • • •
CleanlinessComfort Remote controller Work & Servicing Control features Others
Features
*2
*1Applicable when BRC1E62 is used *2Applicable when wired remote controller is used*3For the outdoor units
*4Applicable when BRC1C61 is used*5Option
Switc
habl
e fa
n sp
eed
(3 s
tep)
*1
Auto
airf
low
rate
Auto
sw
ing
Prog
ram
me
"Dry
"
Hig
h fa
n sp
eed
mod
e
On/
Off
timer
*1
Off
timer
(pro
gram
med
)
*1
Wee
kly
sche
dule
tim
er
*1
Setp
oint
rang
e se
t
*1*3
Setp
oint
aut
o re
set
Pre
char
ged
for
up to
30
m
Mou
ld-p
roof
air
filte
r
Filte
r sig
n
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Con
trol b
y 2
rem
ote
cont
rolle
rs
Auto
-rest
art
•
DIII
-NET
com
mun
icat
ion
stan
dard
*5
Dra
in p
ump
mec
hani
sm
*3
Low
gas
pre
ssur
e de
tect
ion
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Nig
ht q
uiet
ope
ratio
n
BRC7EB519A signal receiver must be added to the indoor unit.
Wireless remote controller and signal receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit (Installed type)
Compact design and easy installationCompact design and easy installation
Accessory required for indoor unit.Option
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable not included. Cables must be procured locally.
FAQ100CNEW
Note: Remote controller cable not included. Cables must be procured locally.
16
Comfortable
Maintenance possible from the front of the unitAll maintenance tasks can be carried out via front access. During service work, attachment and detachment of parts is easier.
Two selectable temperature-sensors
Comfort even on the far side of the roomTo carry air to the far side of long rooms, extra-high airflow adds 10% more fan speed the "high" setting. Air discharge strength is selected from the remote controller by field setting.
Easy cleaning
6-direction piping offers greater installation flexibility.
Compact & Sophisticated design
FAQ100
Flaps neatly close when not in use
Easy installing and servicing
Drain pump kit is available as option.
Removable and washable grille
Connection to a centralised control system is available without option
Drain pump kit can be installed on either left and right side of the air conditioner.
Height of drain up
Drain pump kitIndoor unit
Installs onto side of unit.
1,000 mm
Refrigerant piping
1,200mm
340mm
370mm shorter
9kg lighter
Height
FAQ100BV
360mm
Width 1,570mm
Weight 26kg
FAQ100C
340mm
1,200mm
17kg
Depth 200mm 240mm
Auto airflow rate (When BRC1E62 is used)
Switchable fan speed: High/Middle/LowCondensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean.
Non-flocking flaps
Flat panel, easy to wipe dust off
An air discharge modes ensure comfortable air distribution across the entire room
Auto swing (up and down) and wide-angle louvers (left and right by hand) facilitate even room temperature
Auto-swing 5-level air direction setting
Gettable to 5 different levels
Soft material louver bends airflow over a wider area
Wide-angle louvers (by hand)
Right pipe
Left pipe
Back-left pipe
Back-right pipe
Bottom-left pipe
Bottom-right pipe
17
BRC1E62
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable not included. Cables must be procured locally.
Control featuresWork & ServicingComfort Cleanliness OthersOption
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Features
*1Applicable when wired remote controller is used*2For the outdoor units*3Applicable when BRC1E62 is used*4Applicable when BRC1C61 is used*5Option
• *2• *1 *2 *2• • • • • • • *2• •
Switc
habl
e fa
n sp
eed
(2 s
tep)
Prog
ram
me
"Dry
"
Nig
ht q
uiet
ope
ratio
n
*5
Anti-
bact
eria
l air
filte
r
•
Silv
er io
n an
ti-ba
cter
ial
drai
n pa
n
Pre
char
ged
for
up to
30
m
Filte
r sig
n
Self-
diag
nosi
s fu
nctio
n
•
Emer
genc
y op
erat
ion
Low
gas
pre
ssur
e de
tect
ion
Anti
corro
sion
trea
ted
heat
exc
hang
ers
Hig
h ef
ficie
ncy
filte
r
Con
trol b
y 2
rem
ote
cont
rolle
rs
Auto
-rest
art
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
•
DIII
-NET
com
mun
icat
ion
stan
dard
Two
sele
ctab
le
tem
pera
ture
-sen
sors
FBQ50/60/71/100/125/140D
BRC4C64A signal receiver must be added to the indoor unit.
Wireless remote controller and signal receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit (Separate type)
Note: Remote controller cable not included. Cables must be procured locally.
Wired LCD remote controller
BRC1C61
*5
Long
-life
filte
r
•
Dra
in p
ump
mec
hani
sm
Remote controller
*3 *3 *3 *3 *4
Setp
oint
rang
e se
t
Wee
kly
sche
dule
tim
er
Setp
oint
aut
o re
set
Off
timer
(pro
gram
med
)
On/
Off
timer
Enhance comfort using cleverly placed ductsEnhance comfort using cleverly placed ducts
Accessory required for indoor unit.Option
18
Increased freedom of design thanks to variable control over external static pressure
Comfort airflow achieved in accordance with conditions such as duct length.Using a DC fan motor, the external static pressure can be controlled within a range of 50 Pa to 200 Pa.
Thin, lightweight indoor unit makes delivery and installation easy.
With a height of only 300 mm, installation is possible even in buildings with narrow ceiling spaces.
Drain pump is equipped as standard accessory with 700 mm lift.
300
100D 125D 140D
1,000
36
1,400700
HeightIndoor unit
WidthDepth
46Machine weight
50/60/71D
Freely control external static pressure
50 Pa 200 Pa
Set to high static pressure for advanced needs such as when using dampers and long ducts.
Set to low static pressure when ducts
are short.
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Ventilation grille
Door-installedventilation grille
Ventilation grille
Wall-installedventilation grille
Under-door cutout
Under-door cutoutWhen air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Ventilates air through the partitioning wall. (See right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
(mm)
(mm)
(mm)
(kg)
Quiet operation
When testing standard integrated ceiling units that employ duct work, much time used to be required to adjust airflow to the right level. Thanks to the ability provided by Daikin to automatically perform this troublesome adjustment using a remote controller, this step is now quick and easy. (Adjust by H tap .)1. Adjust to approximately ±10% of the rated H tap airflow. 2. Once actual operation has begun, adjustment of the rated airflow is not possible.
Reduced installation timeUse remote controller to adjust airflow
Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Silver ion anti-bacterial drain pan
Maintenance is easy because the drain pan can be removed.
Easy maintenance
Clean
Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control.This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Two selectable temperature-sensors
Comfortable
dB(A)
100D 125/140DHighLow
38 4033 36
50/60/71D3732
700 mm
300mm
Easier connection with the centralised control system
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
19
Note: Remote controller cable not included. Cables must be procured locally.
Wired LCD remote controller
BRC1C61
Floor Standing Type
New airflow control for more comfortNew airflow control for more comfort
Long
-life
filte
r
FVQ50/60/71/100/125/140C
• • •*2 *5 • *4 •• • • • • • • • • *4
CleanlinessComfort Remote controller Work & Servicing Control features Others
Features
*3
*1Applicable when BRC1E62 is used*2Applicable for FVQ50-100*3Applicable when wired remote controller is used *4For the outdoor units
*5Applicable when BRC1C61 is used
Switc
habl
e fa
n sp
eed
(3 s
tep)
•
Inde
pend
ent u
p-an
d-do
wn
airfl
ow
*1
Auto
airf
low
rate
Auto
sw
ing
Prog
ram
me
"Dry
"
Hig
h fa
n sp
eed
mod
e
On/
Off
timer
*1
Off
timer
(pro
gram
med
)
*1
Wee
kly
sche
dule
tim
er
*1
Setp
oint
rang
e se
t
*1*4
Setp
oint
aut
o re
set
Pre
char
ged
for
up to
30
m
Anti-
bact
eria
l air
filte
r
Filte
r sig
n
Emer
genc
y op
erat
ion
Self-
diag
nosi
s fu
nctio
n
Con
trol b
y 2
rem
ote
cont
rolle
rs
Auto
-rest
art
Anti
corro
sion
trea
ted
heat
exc
hang
ers
•
DIII
-NET
com
mun
icat
ion
stan
dard
*4
Low
gas
pre
ssur
e de
tect
ion
Gro
up c
ontro
l by
1 re
mot
e co
ntro
ller
Exte
rnal
com
man
d co
ntro
l
Cen
tral r
emot
e co
ntro
l
Inte
rlock
con
trol
Two
sele
ctab
le
tem
pera
ture
-sen
sors
Nig
ht q
uiet
ope
ratio
n
Accessory required for indoor unit.Option
BRC1E62 can be
incorporated into the
main unit.
(Wired Remote Controller)
Navigation Remote Controller
Note: Remote controller cable not included. Cables must be procured locally.
BRC1E62
20
Quiet operation
Quick and easy installation and maintenance
Lightweight indoor unit
Easier connection with the centralised control system.
Enables smooth transport and installation of the indoor unit.
The grill will not open even upon impact.
Long-life filter lasts about 1year * maintenance not requiredEnergy saving
A DC fan motor improves efficiency.
* For dust concentration of 0.15 mg/ m3
Employs a safety lock function of suction grill.
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
100C 125C 140CHigh
Indoor unit 50/60/71C
50 51 5343Middle 47 48 5141Low 44 46 4838
dB(A)
39 47
100C 125C 140C
Weight
Indoor unit 50/60/71C(kg)
Comfortable fan speed control
To carry airflow to the far side of the room, airflow rate can be increased 5% or 10% depending on the installation condition or customer's request. (Field setting by remote controller.)
High fan speed mode
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Programme "Dry"
(applicable for FVQ50-100)
Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.
Auto airflow rate is selectable.
Example applications
When cooling
Turning louvers and upward and leaving and horizontal will reduce uneven room temperature.
New comfortable airflow control1) Left and right directions
2) Up and down directions Independent up-and-down airflow directions facilitate even room temperature and help save energy.
New unit
(by remote controller)
(by hand)
Freely select both up and down airflow direction with 8-louver (horizontal blade) operation.
Upper louver (1)Upper interlocking louvers (4)Lower interlocking louvers (2)Lower louver (1)
Each set of louvers to can be independently adjusted. (Manual adjustment)
Auto swing direction is selectable from 3 patterns to suit the layout of the room.
Pattern 1 Wide swing toward the front
When installed in the center of a wall. When installed in the corner of a room.
Pattern 2 Swing on the left side Pattern 3 Swing on the right side
Switchable fan speed: High/Middle/Low and Auto("Auto" is applicable when BRC1E62 is used.)
(Applicable when BRC1E62 is used.)
21
OUTDOOR UNIT
Compact Outdoor unit
Easy installation and maintenancePre charged for up to 30 metres
Long piping length
4-direction piping offers greaterlayout freedom
Separation available
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.
A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified.
Facilitates pump down (Refrigerant recovery function)
Effective gas monitoring reduces the labor required for operation, maintenance, and repairs.
Low gas pressure detection function
The maximum capacity is maintained within a set level of power consumption, which makes it possible to keep comfort and effective demand control.
As the bottom frame is subject to corrosion, corrosion-proof galvarium steel plate is adopted to enhance the durability.
Heat exchange fins provided with anti-corrosion treatment
Durability
Through use of a V-cut propeller fan that imitates the efficiency of the swan, a migratory bird, airflow becomes smooth and loss is reduced.
Energy saving
Construction
Non-treated fin
Anti corrosion treated heat exchangers
Aluminium
AluminiumCorrosion resistantacrylic resin
Hydrophilic film
Allowed refrigerant piping length and level difference
Note : 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.
Demand Control Function
8:00 12:00 16:00 20:00
Pow
er
cons
umpt
ion
Time
Limitation
* Required for KRP58M51 (Option)
Max. length
Max. leveldifference
Pre charged1
ALL model
30 m
50 m(Equivalent length 70m)
30 m
The outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installation piping work.
*Pump-down function is available for pre-charged refrigerant amount.
(RZR100-140 only)
Night time quiet operation functionThe Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.
4849
RZR71LVVM4
48RZR50/60LVVM4
Sound level1 (dB(A))
RZR100LVVM4/LUY1450RZR125LUY1450
4445
44
4546RZR140LUY14
Rated2 Night Quiet Mode
Note : 1Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 2Value when cooling. Value will differ when heating. Note : 3In case of RZR100
Reducing noise will reduce capacity slightly.
100
50
0
8:00
Peak in outdoor temperature
8 hours
Rated
10 hours
Quiet modeQuiet mode
12:00 16:00 20:00 0:00 4:00 8:00
45
49
Cap
acity
(%)
Load
(%)
Ope
ratio
n So
und3 (d
B(A)
)
Φ550V-cut propeller fan
Imitating the performance of the swan
(RZR50-71 only)
(RZR100-140 only)
RZR50LVVM4RZR60LVVM4RZR71LVVM4 RZR100LVVM4
RZR100LUY14RZR125LUY14RZR140LUY14
22
These two features work to reduce noise. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence.
Smooth Air Inlet Bell Mouth and Aero Spiral Fan
Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence.
The high efficiency compressor to achieve a high COP
2
1
DC fan motorEfficiency improved in all areas compared to AC motors, especially at low speeds.
Sine wave DC inverter
>> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency.
Sucked gas is compressed in the scrolling part before the heated motor, so that the machine compress the non-expanded gas, resulting in high efficiency compression.
>> The structural scrollEnergy savings is realised, eliminating the friction and the leakage of refrigerant gas.
>> Swing compressor
Compressor equiped with Reluctance DC motor
3
DC fan motor structure
With the bent blade edge
Without the bent blade edge
ReluctanceDC motor
Scroll section
Suction
Discharge Motor section
RZR50/60/71/100LVVM4
Technology for energy efficiency
Swing bushing Refrigerant gas
Piston by incorporated blade and roller.
500 30 60 90 120
60
70
80
90
Small load Large loadLow capacity High capacity
Reluctance DC Motor
Conventional DC motor
More than 20%
AC motor
Rotational speed (rps)
Mot
or e
ffici
ency
(%)
Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor.
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
*2. The torque created by the change in power between the iron and magnet parts.
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.
RZR125/140LVVM4, RZR100/125/140LUY14
(RZR100-140 only)
3
1
2
23
LCD REMOTE CONTROLLER Optional accessory
Clear Display
Navigation Remote Controller(Wired Remote Controller BRC1E62)
- 5 actions per day can be scheduled for each day of the week.- The holiday function will disable schedule timer for the days that have been set as holiday.- 3 independent schedules can be set. (e.g. summer, winter, mid-season)
Display is available in 11 languages.
Dot matrix display Backlight display
ConvenienceWeekly schedule Multilingual display
Easy-to-read LCD remote controller allows various system Remote controller options are shown on the page introducing each indoor unit model.
NEW
(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish).NEW
A combination of fine dots enables various icons.Large text display is easy to see.
This simple, modern designed remote controller with fresh white colour matches your interior design. Operation is much easier and smoother, just follow the indications on the navigation remote controller.
Energy savingNEW
- Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.- Period can be preset from 30 to 180 minutes in10-minute increments.
Off timer (programmed)
Setpoint range setNEW Setpoint auto reset
Restaurant sampleRestaurant opened
Temperature is set to 27ºC
27°C
- Saves energy by limiting the min. and max. set temperature.
- Avoids excessive heating or cooling.
- This function is convenient when the remote controller is installed at a place where any number of people may operate it.
- Even if the set temperature is changed, it returns to the preset temperature after apreset period of time.
- Period selectable from 30min/60min/90min/120min.
Full tables at lunchtimeThen is lowered to 24ºC for crowded room
24°C
After 30 minutes*Automatically returns to preset temperature (27ºC)
*Setting possible for after 30, 60, 90, and 120 minutes.
Returns to
27°Cautomatically
24
Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.)
Facilitates maintenance and repairAll initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set without having to use stepladder access for manual setting.Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically).
Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction.
SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying interlocking operations.
Easily adaptable to large-scale, high-function, centralised remote control systems.Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.
LCD panel shows operating status in letters, numbers, and motion.Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Programming time display Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
CEILING MOUNTED CASSETTE TYPECOMPACT MULTI FLOW TYPECEILING SUSPENDED TYPE
BRC7E531WBRC7F633F
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE BRC4C64
BRC7EA66WALL MOUNTED TYPE BRC7EB519
Wired remote controller has built-in temperature-sensor (Applies to wired remote controllers (BRC1C61/1E62))
(Applies to wired remote controller (BRC1E62))
control configurations and can control multiple indoor units.
Signal receiver unit (For ceiling mounted cassette type)
Wireless remote controller for each indoor unit type
LCD wireless remote controller
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type.
Wireless remote controller
BRC7F633F
The wireless remote controller is supplied in a set with a signal receiver.Signal receiver unit is contained inside decoration panel or indoor unitShape of signal receiver unit differs according to the indoor unit.
The rubber switch and the oil-resistant plastic casing are adopted for durability.Only 17 mm thick. Can be installed either recessed or exposed.
Easy to read because of large LCD screen.
Wired LCD remote controller
BRC1C61
25
LCD REMOTE CONTROLLER
Central remote controller
Interface adaptor for SkyAir series
Easily adaptable to large-scale, high-function, centralised remote control system.
Centralised control, with setting as simple as it is with a standardremote controller, of up to 64 groups (1,024 indoor units) is possible.
DCS302CA61 (Option)
DTA112BA51 (Option)
With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways.
DCS601C51 (Option)
Unified on/off controller
Centralised control of on/off by group or all at once for up to 256 indoor units.
DCS301BA61 (Option)
Schedule timer
Unified control of weekly schedule for up to 1,024 indoor units.
DST301BA61 (Option)
Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time.
Simple system provides a diverse assortment of control modes.
Control by 1remote controller
Control pattern Wired remote controller Wireless remote controller
Control by 2remote controllers
Group control
Control by external command
Centralised remotecontrol
Interlock controlwith Heat Reclaim
Ventilator
(Basic system)
Link by remote controller group control.
Zone link control by centralised control.
For control from 2 locations such as in room and control room, exits, etc.
For simultaneous control of up to 16 indoor units.
Centralised control of up to 64 indoor groups from remote locationup to 1 kilometer away.
Control by 1 wireless remote controller and 1 wired remotecontroller (See note 2, 3)Signal receiver unit installed on indoor unit
Signal receiver unit installed on indoor unit
Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Can also be operated independently by remote controller.
Central remote controller (option)
Heat ReclaimVentilator
Can be operated simultaneously or independently by remote controller (set by ventilation mode)
Heat ReclaimVentilator
Central remote controller (option)
Non-polar, double-core (max. wiring length 500 m)
Connects 2 wired remote controllers (See note 1)
Automatic address setting function Automatic address setting functionSignal receiver unit installed on 1 indoor unit
Optional wiring adaptor for electrical appendices is necessary
Central remote controller (option)
Can be operated simultaneously by remote controller (set by ventilation mode)
Heat ReclaimVentilator
Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking
Central remote controller (option)
Heat ReclaimVentilator
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room.
Optional wiring adaptor for electrical appendices is necessary
Interface adapter for SkyAir series (option) is required (See note 4)
Interface adapter for SkyAir series (option) is required (See note 4)
Note: 1BRC1E62 can connect to BRC1E62 only. 2It is not possible to use two wireless remote controllers. 3BRC1E62 cannot connect to wireless remote controller. 4The ceiling mounted cassette type <Round Flow>, wall mounted type, duct connection middle and high static pressure type, and floor standing type come standard with an interface adaptor for SkyAir series.
Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin VRV system.Necessary for interface adaptor for SkyAir series with the central remote control units shown at above.
The interface adaptor for the SkyAir series is optional except for the ceiling mounted cassette type <Round Flow>, wall mounted type, duct connection middle and high static pressure type, and floor standing type.
26
Abundance of functions that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Mould-proof drain pan prevents growth of mould in highly humid conditions.
Mould-proof drain pan
Cleanliness
Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.
Silver ion anti-bacterial drain panThe Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it.
Anti-bacterial air filter
Sanitary filter has mould-resistant treatment.
Mould-proof air filter
Note: Wireless remote controllers have no temperature-sensor.
Use the temperature-sensor in the indoor unit when controlling air conditioning from another room.
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room.
Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner.
High setting provides maximum reach while low setting minimises drafts.
Auto-swing Programme "Dry"
Switchable fan speed
(1) Air direction in standard setting
(2) Air direction in ceilingsoiling prevention setting
(standard, ceiling soiling prevention)
Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.
You can freely set 2 air discharge setting by remote controller.
Swing pattern selectionDelivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.
High-ceiling application
Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.
Auto airflow rate
Two selectable temperature-sensors
Comfort
The air flow direction can be fixed at your desited angle by the remote controller.
Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level.
Remote Controller
Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.
Off timer (programmed)
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
On/Off timer
Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature.
Weekly schedule timer
Even if the set temperature is changed, it returns to the preset temperature after a preset period of time.
Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling.
Setpoint auto reset
Setpoint range set
Applicable for wall mounted typeYou can increase fan speed approximately 10% higher than the "high" setting.
High fan speed mode The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.
Night quiet operation
Independently adjust (manually) the eight horizontal blade louvers in both up and down directions to achieve an airflow that reduces uneven room temperature.
Independent up-and-down airflow
27
If there is a malfunction elsewhere in the system, the fan or compressor can still be operated.
Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly.
You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.)
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Emergency operation
Low gas pressure detection
Group control by 1 remote controller
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room.
External command control
Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away.
Central remote control
Enables interlocking control with external equipment such as Heat Reclaim Ventilator.
Interlock control
The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates.
Self diagnosis function
Two types are available: 65% and 90% colorimetry.
High-efficiency filter unitYou can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.
Fresh-air intake kit
Work and Servicing
Control features
Options
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
Maintenance is not required for one year (two years when a ceiling mounted cassette type is used).
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.
The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
Drain pump mechanism
Long-life filter
Pre charged for up to 30 metres
Filter sign
Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.
Ceiling soiling prevention function
If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.
Ultra long-life filter
Auto-restart
Using 2 remote controllers you can operate the equipment locally or from a remote location.Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.
Control by 2 remote controllers
RXS50FA/60F/71F,RKS25A-60A : 10 m*Applicable to RZR50-140.
Requires no maintenance for about 4 years* (10,000h) in stores and offices.*For dust concentration of 0.15 mg/m3
*Required for KRP58M51 (Option)
*Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending.
Note:
Others
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.In high corrosive areas, regular maintenance needs to be carried out.
Anti corrosion treated heat exchangers
Standardly equipped interface enables connection to centralised control system without need of an adaptor.
DIII-NET communication standard
28
16,000 (5,800-19,100)
19,800 (5,800-20,500)
8,550 (4,100-10,250)
11,600 (4,100-12,600)Btu/h
SPECIFICATIONS
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
cfm
25 35
286X575X575
1 Phase, 220–240 V, 50 Hz2.5
(1.2-3.0)3.4
(1.2-3.7)
0.73 1.103.42 3.09
4.7 (1.7-5.6)
5.8 (1.7-6.0)
1.62 2.072.90 2.80
55X700X700
2.7
VP20 (I.Do/ 20XO.Do/ 26)
17.5
29.5/24.5 32/25
10 to 46
46 47 49550X765X285
34735X825X300
47
1.00.6
Ivory white 14 to 23
Both liquid and gas piping
o/ 6.4o/ 9.5 o/ 12.7
2015
3020
Hermetically sealed swing type
o/ 18.0 (Hole)
White
(Charged for 10 m)1.51.1
(Charged for 10 m)Sound level2
FFQ25BV1B4
RKS25AVMG4
FFQ35BV1B4
RKS35AVMG4
50 60FFQ50BV1B4
RKS50AVMG4
FFQ60BV1B4
RKS60AVMG4
kWPower consumption
°CDB
°CWBCertified operation range
Certified operation range
Motor outputCompressor
ModelName
Indoorunit
Indoor unit
Outdoor unit
Dimensions(HXWXD)
Colour
mmmm
Sound level (H/L)2 dB(A)
kWRefrigerant charge (R-410A)
dB(A)Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weightkgkg
kg
UnitDecoration panel
Airflow rate (H/L) 9/6.5 10/6.5317/229 353/229
36/27 41/32
12/8 15/10423/282 529/353
m3/min
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
kW
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
----------
Cooling capacity1
Rated (Min. - Max.)
Cooling1
W/WCOP
Outdoor unit
Btu/h 24,200 (10,900-27,300)
34,100 (17,100-38,200)
42,700 (19,500-47,800)
47,800 (21,200-52,600)
17,100 (7,900-19,100)
20,500 (8,900-21,500)
dB(A)
CEILING MOUNTED CASSETTE TYPE
Cooling capacity1,2
Rated (Min. - Max.) kW
°CDBCoolingCertified Operation range
Sound level3
°CWBCoolingCertified Operation range
Motor outputCompressor
ModelName
Indoor unit
Outdoor unit
Dimensions(HXWXD)
Colour
mmmm
dB(A)
kWRefrigerant charge (R-410A) kg
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weight kg
kgUnitDecoration panel
Airflow rate (H/L) m3/mincfm
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Cooling
Sound level (H/L)3
Indoorunit
71FCQ71LUV14
RZR71LVVM4
Hermetically sealed swing type1.76
7.1 (3.2-8.0)
o/ 9.5o/ 15.9
1,170X900X320
24
298X840X84050X950X950
5.5
----------
1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
30
Ivory white
Fresh white
Both liquid and gas piping
50 (Equivalent length 70)
Hermetically sealed scroll type
o/ 26.0 (Hole)VP25 (I.Do/ 25XO.Do/ 32)
21 to 46
14 to 25
kWPower consumption Cooling1
100FCQ100LUV14
RZR100LUY14
43/32
92
1.82.7
(Charged for 30 m)
32/20
10.0 (5.0-11.2)
125FCQ125LUV14
RZR125LUY14
44/34
97
2.43.7
(Charged for 30 m)
33/22.51,130/706 1,165/794
12.5 (5.7-14.0)
140FCQ140LUV14
RZR140LUY14
44/36
49 50
3.1
14.0 (6.2-15.4)
1.99 2.78 3.68 4.91
Night quiet mode
50FCQ50LUV14
RZR50LVVM4
1.12
5.0 (2.3-5.6)
60FCQ60LUV14
RZR60LVVM4
35/28
48
595X845X30043
21
256X840X840
1.351.6
(Charged for 30 m)
21/13.5741/477
6.0 (2.6-6.3)
1.03 1.40W/WCOP 3.57 3.60 3.40 2.854.87 4.30
44 4645
Outdoor unit
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
29
SPECIFICATIONS
CEILING SUSPENDED TYPE
11,600 (4,100-12,600)Btu/h
W/WCOP
35
1 Phase, 220–240 V, 50 Hz
37/32195X960X680
24
3.4 (1.2-3.7)
1.053.24
White
VP20 (I.Do/ 20XO.Do/ 26)
10 to 46o/ 6.4
47550X765X285
34
1.0 (Charged for 10 m)0.6
Ivory white
2015
Hermetically sealed swing type
o/ 9.5
o/ 18.0 (Hole)
°CWB
kW
kWPower consumption
°CDBCertified operation range
Certified operation range
Motor outputCompressor
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A) kg
dB(A)Sound level2Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Cooling1
Outdoor unit
Machine weight kg
Airflow rate (H/L) m3/min 13/10458/353
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Sound level (H/L)2
Indoorunit
FHQ35BV1B4
RKS35AVMG4
Both liquid and gas piping
Cooling capacity1
Rated (Min. - Max.)
cfm
14 to 23
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Outdoor unit
Refrigerant charge (R-410A)
20,500 (8,900-21,500)Btu/h 34,100
(17,100-38,200)42,700
(19,500-47,800)17,100
(7,900-19,100)24,200
(10,900-27,300)
VP20 (I.Do/ 20XO.Do/ 26)
Hermetically sealed swing type
30
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
60FHQ60BVV1G4
RZR60LVVM4
6.0 (2.6-6.3)
39/-/35195X1,160X680
595X845X30043
27
48
17/-/14600/-/494
1.351.6
(Charged for 30 m)
1.69
CEILING SUSPENDED TYPE
3 Phase, 380–415 V, 50 Hz
Ivory white °CWB
kW
kWPower consumption
°CDBCertified operation range
Certified operation range
Motor output
CoolingNight quiet mode
Compressor
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A)
kg
dB(A)dB(A)
Sound level3
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H/M/L) m3/min
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Sound level (H/M/L)3
Indoorunit
Both liquid and gas piping
Cooling capacity1,2
Rated (Min. - Max.)
cfm
125100FHQ100BV1B4 FHQ125BV1B4
RZR100LUY14 RZR125LUY14
42/-/37 44/-/39195X1,400X680 195X1,590X680
92 97
32 35
Hermetically sealed scroll type
49 50
24/-/20 30/-/25847/-/706 1,059/-/883
10.0 (5.0-11.2)
12.5 (5.7-14.0)
2.1 2.62.7
(Charged for 30 m)3.7
(Charged for 30 m)
50FHQ50BVV1G4
RZR50LVVM4
5.0(2.3-5.6)
4544
1.12
1.39
White White
3.51 4.55
21 to 46
14 to 25
1,170X900X320
1 Phase, 220–240 V, 50 Hz
50 (Equivalent length 70)
71FHQ71BV1B4
RZR71LVVM4
1.76
2.503.56W/WCOP 3.60 2.85 2.752.84
7.1 (3.2-8.0)
Cooling1
Outdoor unit
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
30
°CWB
Cooling capacity1,2
Rated (Min. - Max.) kW
kWPower consumption
°CDBCertified Operation range
Certified Operation range
Sound level3
Motor outputCompressor
ModelName
Indoor unit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A) kg
dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Machine weight kg
Airflow rate (H/M/L)
Outdoorunit
Colour
mm
Heat insulation
Max. interunit piping length mmMax. installation level difference
Power supply
Type
Cooling1
Cooling
Sound level (H/M/L)3
Indoorunit
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
WALL MOUNTED TYPE
m3/mincfm
W/WCOP
Outdoor unitOutdoor unit
Btu/h34,100
(17,100-38,200)
100FAQ100CVEA4
RZR100LVVM4
49/45/41
17340X1,200X240
49
Ivory white
Fresh white
Hermetically sealed swing type
3.35 (Charged for 30 m)
10.0(5.0-11.2)
26/23/19
14 to 25
900X940X32078
2.03
918/812/671
3.372.97
1 Phase, 220–240 V, 50 Hz
o/ 9.5
30Both liquid and gas piping
o/ 15.9
o/ 26.0 (Hole)
21 to 46
50 (Equivalent length 70m)
VP13 (O.Do/ 18 X I.Do/ 13)
Btu/h 17,100 (7,900-19,100)
20,500 (8,900-21,500)
24,200 (10,900-27,300)
34,100 (17,100-38,200)
42,700 (19,500-47,800)
47,800 (21,200-52,600)
Power supply 1 Phase, 220–240 V, 50 Hz1 Phase, 220–240 V, 50 Hz
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
ModelName
Indoor unit
Outdoor unitIndoor unitOutdoor unit
kW
°CDBCooling
°CWBCooling
Cooling
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressor
Indoorunit
Dimensions (HXWXD)Air filter
Colour
mm
dB(A)
kWRefrigerant charge (R-410A)Sound level4
Cooling (H/L)Sound level4
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate(H/L)
Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
----------
Both liquid and gas piping
mmOutdoor unit
Ivory white
kWCooling1Power consumption
Pa
cfm
Night quiet mode dB(A)
External static pressure(Middle-High)
Cooling capacity1,2
Rated (Min. - Max.)
30
21 to 46
14 to 25
m3/min
50FBQ50DV14
RZR50LVVM4
5.0 (2.3-5.6)
50 (Equivalent length 70)
VP25 (I.Do/ 25XO.Do/ 32)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
1.12
1.39
60FBQ60DV14
RZR60LVVM4
6.0(2.6-6.3)
300X1,000X700---------- 5
36
595X845X30043
Hermetically sealed swing type1.351.6
(Charged for 30 m)
635/53018/15
1.69
37/32
48
71FBQ71DV14
RZR71LVVM4
7.1 (3.2-8.0)
1.76
2.22
44
50-200 3
300X1,400X70046
1,170X900X320
100FBQ100DV14
RZR100LUY14
10.0 (5.0-11.2)
1,130/812
92
1.82.7
(Charged for 30 m)
32/23
2.82
38/33
4945
3 Phase, 380–415 V, 50 Hz
125FBQ125DV14
RZR125LUY14
12.5 (5.7-14.0)
97
2.43.7
(Charged for 30 m)
1,377/98839/28
3.73
40/36
50
140FBQ140DV14
RZR140LUY14
14.0(6.2-15.4)
4.71W/WCOP 3.60 3.56 3.20 3.55 3.35 2.97
2.9
46
Hermetically sealed scroll type
Note : 1Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Initial setting is standard.4Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.5Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.
31
SPECIFICATIONSFLOOR STANDING TYPE
Power supply 1 Phase, 220–240 V, 50 Hz/220–230 V, 60 Hz 3 Phase, 380–415 V, 50 Hz
ModelName
Indoor unit
Outdoor unitOutdoor unit
kW
°CDBCooling
°CWBCooling
Cooling
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressor
Indoorunit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A)Sound level3
Cooling (H/M/L)Sound level3
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate(H/M/L)
Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
Fresh white
Both liquid and gas piping
mmOutdoor unit
Ivory white
kWCooling1Power consumption
cfm
Night quiet mode dB(A)
Cooling capacity1,2
Rated (Min. - Max.)
30
21 to 46
14 to 25
m3/min
50 (Equivalent length 70)
VP20 (I.Do/ 20XO.Do/ 26)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
1,850X600X27039
595X845X30043
Hermetically sealed swing type
1.6 (Charged for 30 m)
635/565/49418/16/14
43/41/38
48
71FVQ71CVEB4
RZR71LVVM4
60FVQ60CVE4
RZR60LVVM4
50FVQ50CVE4
RZR50LVVM4
7.1 (3.2-8.0)
1.761.351.12
2.58
2.3 2.8 3.4
44
140FVQ140CVEB4
RZR140LUY14
100FVQ100CVEB4
RZR100LUY14
125FVQ125CVEB4
RZR125LUY14
1,850X600X35047
2.7 (Charged for 30 m)
3.7(Charged for 30 m)
988/883/77728/25/22
988/918/84728/26/24
1,059/988/91830/28/26
50/47/44 53/51/4851/48/46
1,170X900X32045 46
92
49
97
50
W/WCOP 2.75
6.0 (2.6-6.3)
1.843.26
5.0 (2.3-5,6)
1.273.94
13.5(6.2-15.4)
5.40
10.0 (5.0-11.2)
3.28
12.5 (5.7-14.0)
4.392.503.05 2.85
Hermetically sealed scroll type
Btu/h 24,200 (10,900-27,300)
20,500 (8,900-21,500)
17,100 (7,900-19,100)
46,100 (21,200-52,600)
34,100 (17,100-38,200)
42,700 (19,500-47,800)
Note : 1Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
32
Indoor unit
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
Round flow type: List of optional parts required to achieve different flow patterns
1In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.3It is not possible to use panel spacers in a 2-way flow installation. 4It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
Panel/grille related
Independently installable optional parts
Operation control relatedAuxillary function related
Filter related
Optional accessory parts
Independently installable optional partsOptional accessory parts
Independently installable optional partsOptional accessory parts
Panel spacer1
Panel spacer1 o o ox oWireless remote controller o o oo o
Fresh air intake kit (direct mount) o o oo ox o o
xx
High-efficiency filter2
Filter related Ultra-long-life filter2
o o ox
xUltra-long-life filter2 o o o xx
High-humidity operation kit
Panel/grille relatedOperation control relatedAuxillary function related
Panel spacer1
Wireless remote controller
Fresh air intake kit (direct mount)High-humidity operation kit
All round flow 4-way flow
o3 o3 xx o3
o3 o
x
xxo o
o3 o xx
o ox o o x
o3 o o xx
3-way flow 2-way flow
1-way branch / unit 3-way flowBranch duct1(Chamber type)(Round duct type)
o o o4 xx o2-way branch / unit 2-way flow1-way branch / unit 2-way flow
x o o4 xx ox o o4 xx o
Branch duct connection
Wireless remote controller
Fresh air intake kit (direct mount)
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
Panel spacer1 Wireless remote controller
Fresh air intake kit (direct mount)
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
Panel spacer1 Wireless remote controller
Fresh air intake kit (direct mount)
Fresh air intake kit (Chamber type)1,2 o o ox o
Fresh air intake kit (Chamber type)1,2 o3 o xx o
oo
xoo
o3
o
x
x
x
o
o o o
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (Chamber type)1,2
High-efficiency filter2
High-humidity operation kit
Ultra-long-life filter2
Cooling only
OPTIONS
Touch Controller4 DCS601C51
Note: 1Refer to page 10 for the details. 2Required for installing high-efficiency filter or ultra long-life filter. 3Wiring for wired remote controller to be procured locally.4The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5Installation box for adaptor PCB (KRP1H98) is necessary.
Kit name
DCS302CA61BRC1E62
DCS301BA61DST301BA61
KRP1C63
KDDFP55B160
KDBH55K160FKDBP55H160FA
KKSJ55KA160
KDDP55B160KDDP55B160KKDDP55X160
KRP4AA53
KAFP551K160
KAFP556B80KAFP557B80KAFP552B80
KDTP55K80
KDJP55B160KDJP55B80BRC7F633FBRC1C61
KAFP553B80
KDTP55K160KAFP556B160KAFP557B160KAFP552B160KAFP553B160
BYCP125K-W1
KRP1H98
KAFP55B160KAFP55H160H
FCQ71LUV14 FCQ100LUV14 FCQ125LUV14FCQ50LUV14 FCQ60LUV14 FCQ140LUV14Name of option Remark
Chamber type
Decoration panel
Fresh air intake kit1
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Adaptor for wiring5
Without T-joint pipe and fanWith T-joint pipe, without fan
Direct installation type
Sealing material of air discharge outletPanel spacer
Chamber connection kit2Insulation kit for high humidity
Wiring adaptor for electrical appendices5
Installation box for adaptor PCB
High-efficiency filter(including chamber)
Filter chamber Replacement long-life filterUltra long-life filterReplacement ultra long-life filter
(Colorimetric method 65%)(Colorimetric method 90%)
Replacement high-efficiency filter
(Colorimetric method 65%)(Colorimetric method 90%)
Remote controller
Navigation Remote Controller
Wireless type
Wired type3Wired type3
Branch duct chamber
Remote sensor (for indoor temperature) KRCS01-4B
CEILING MOUNTED CASSETTE TYPE
33
OPTIONS
------------------------------
Touch Controller2
Indoor unit
Kit nameName of option FHQ35BV1B4 FHQ50BVV1G4 FHQ60BVV1G4
BRC7E531W
DCS302CA61DCS301BA61DST301BA61
KHFP5MA35
KAF501DA80KAF501DA56KDU50N60VE
Remark
Kit nameName of option Remark
Touch Controller3
Replacement long-life filter
L-type piping kit (for upward direction)Remote controller
Resin net
Wireless type
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Adaptor for wiringWiring adaptor for electrical appendices3
Interface adaptor for SkyAir seriesInstallation box for adaptor PCB
FFQ25BV1B4 FFQ35BV1B4 FFQ50BV1B4 FFQ60BV1B4Decoration panel
Fresh air intake kit
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Adaptor for wiring2
Direct installation type
Wiring adaptor for electrical appendices2
Sealing material of air discharge outletPanel spacer
Interface adaptor for SkyAir series
Installation box for adaptor PCB
Replacement long-life filter
Remote sensor (for indoor temperature)
DCS302CA61DCS301BA61
DCS601C51DST301BA61
KRP1BA57KRP4AA53KRCS01-1B
BYFQ60B8W1/BYFQ60B3W1
BRC1C61
KDBH44BA60KDBQ44BA60A
KDDQ44XA60
DTA112BA51
KRP1BA101
KAFQ441BA60
Note: 1Wiring for wired remote controller to be procured locally.2Installation box for adaptor PCB (KRP1BA101) is necessary. 3This optional accessory requires DTA112BA51.
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
Note: 1Wiring for wired remote controller to be procured locally.2This optional accessory requires DTA112BA51.3Installation box for adaptor PCB is necessary.
Remote controller Wireless type Cooling only
Cooling only
FHQ71BV1B4 FHQ100BV1B4 FHQ125BV1B4
KRP1BA54DCS601C51
KRP4AA52DTA112BA51KRP1CA93
KHFP5MA160
KAF501DA112 KAF501DA160KDU50N125VE
KRCS01-1BKJB311AAKJB212AA
Remote sensor (for indoor temperature)Electrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)
BRC1E62Navigation Remote Controller Wired type1Wired type1
BRC7EA66BRC1C61BRC1E62Navigation Remote Controller Wired type1
Wired type1
BRC1C61
Touch Controller2
Note: 1Wiring for wired remote controller to be procured locally.2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB (KRP4AA93) is necessary.
WALL MOUNTED TYPEName of option Remark
Central remote controller2
Remote controller
Unified ON/OFF controller2
Schedule timer2
Wiring adaptor for electrical appendices3
Electrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)
Kit nameFAQ100CVEA4
DCS302CA61DCS301BA61DST301BA61DCS601C51KRP4AA51
KJB311AAKJB212AA
Drain-up kit
Installation box for adaptor PCB
Noise filter ( For electromagnetic interface use only)
Remote sensor (for Indoor temperature) KRCS01-4B
K-KDU572EVE
KRP4AA93
KEK26-1A
BRC7EB519Wireless type
BRC1E62Navigation Remote Controller Wired type1Wired type1
Cooling only
Drain pump kit
34
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
Cooling only
Outdoor unitKit name
RZR71LVVM4RZR50LVVM4 RZR60LVVM4 RZR100LUY14 RZR125LUY14 RZR140LUY14Central drain plugWire fixture for preventing overturning
Name of option
Fixture for preventing overturningDemand adaptor
Air direction adjustment grilleDrain plug One set includes 5 pieces for 5 units
Kit nameName of option Remark RKS25AVMG4 RKS35AVMG4KPW937A4
RKS50AVMG4 RKS60AVMG4KPW945A4
KKP937A4
KKPJ5F180K-KYZP15CKPT-60B160
KKP014A4------------------------------ KRP58M51
Refrigerant branch piping kit For twin multi ---------- ---------- KHRP58P216T
KDAJ25K71A
FBQ71DV14FBQ60DV14FBQ50DV14 FBQ100DV14 FBQ125DV14 FBQ140DV14
Service panel
Air discharge adaptor
Adaptor for wiring (interlock for fresh air intake fan)
Remote controller Wireless type
Name of option Remark
Filter chamberReplacement long life filterReplacement long life filter chamber kit
High-efficiency filter1 65%90%
BRC4C64
KTB25KA80WKTBJ25K80FKTBJ25K80T
KTB25KA160WKTBJ25K160FKTBJ25K160T
KAF372AA80KAF373AA80
KAF372AA160KAF373AA160
KDDF37AA80 KDDF37AA160KAF371AA80 KAF371AA160KAF375AA80 KAF375AA160
KDAJ25K140A
BRC1C61
KRP1C64BRC1E62Navigation Remote Controller Wired type2
Wired type2
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Wiring adaptor for electrical appendicesRemote sensorMounting plate for adaptor PCB.4
DCS301BA61DCS302CA61
DST301BA61
KRCS01-4BKRP4A96 5,6
KRP4AA51
Note: 1If installing a high efficiency filter on the unit, an assembly chamber for either bottom or rear suction is required. 2Wiring for wired remote controller to be procured locally. 3The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 4Mounting plate for adaptor PCB is necessary for each adaptor marked . 5Up to 2 adaptors can be fixed for each mounting plate.6Only one mounting plate can be installed for each indoor unit.
DCS601C51Touch Controller3
Kit name
FLOOR STANDING TYPEKit nameName of option FVQ71CVEB4 FVQ100CVEB4FVQ50CVE4 FVQ60CVE4
DCS302CA61DCS301BA61DST301BA61
KAFJ95L160
Remark
Touch Controller2
Replacement long-life filterBRC1C61Remote controller
Navigation Remote ControllerCentral remote controller2
Unified ON/OFF controller2
Schedule timer2
Adaptor for wiring3
Wiring adaptor for electrical appendicesInstallation box for adaptor PCB
Note: 1Wiring for wired remote controller to be procured locally. 2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB (KRP4AA95) is necessary.
FVQ125CVEB4 FVQ140CVEB4
KRP1BA57DCS601C51
KRP4AA52KRP4AA95
BRC1E62Wired type1Wired type1
35
DIMENSIONS (Unit: mm)
CEILING MOUNTED CASSETTE TYPE
Notes:1Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface2In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.
3When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.5Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
950
8
Pipe ConnectionSide
6
A arrow view
Drain ConnectionSide
Note 2
7
950
9
860~
910(C
eiling
open
ing sp
ace)
(Note
4)
420
C
710(Hanging bolt pitch)420
B
300or less
780(
Han
ging
bol
t pitc
h)
860~910(Ceiling opening space) (Note 4)
157
93
2x100=200 85
67
Connection positionof branch duct
C/L(round shape type)160
Connection positionof branch duct
16-M4 Hole
167
(square-shaped type)B arrow view
160
95
81
350
29
213
29
350
80
160
ø100
Connection positionof fresh air intake kit
C/L 157
90
(direct installation type)
67
(knock hole)
Connection positionof branch duct
C arrow view
Connection positionof branch duct
2x10
0=20
0
(round shape type)
(square-shaped type)
196
93
90
8025
95
160
20-M4Prepared hole
167
280
5028
8
80
167
95
157
340840
16510
4Hanging bolt
1
175
55
4-M8~M10
Connection positionof branch duct(round shape type)
Connection positionof branch duct
2
40
80
160
2x100=200
125
(square-shaped type)
C/L
298
20
350
850
Adjus
table(
0~67
5) 55
29
330
160
16-M4 Prepared hole
160
1500
or m
ore
81
93
157
130
Connection positionof branch duct
160
2x100=200
A
55
(square-shaped type)
From t
he floo
r side
2500 o
r more
(Note 4)
67
105
For h
eight
instal
lation
85
150
(requ
ired s
pace
)
350
42
29
64
(round shape type)
27-M4 Prepared hole
60
35 or less (Note 4)
35 or less
3
Connection positionof branch duct
256
160 5
95
50
84055
167
The necessary space is 500mm or more when the air-outlet is blocked with the accessory.Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more.
1500mm or more200mm or more
1500mm or more
1500mm or more1500mm
or more200mmor more
Required space
95
330
165
Connection positionof branch duct
160
20
16-M4 Prepared hole
50
350
12480
175
125
2
(square-shaped type)
4 1
157
246
55
4-M8~M10
2x100=200 80
124
10
Hanging bolt
Connection positionof branch duct
C/L
110
(round shape type)
84055
280
256
40
Adjus
table(
0~67
5)
340
850
Connection positionof branch duct
1500
or m
ore
Connection positionof branch duct
20-M4 Prepared hole
60
From t
he floo
r side
2500 o
r more
130
124
2x100=200
35 or less (Note 4)
55
A
150
84055
160
157256
105
(square-shaped type)Fo
r heig
ht ins
tallat
ion
42
(requ
ired s
pace
)
(Note 4)
95
3 85124
35 or less
5
(round shape type)
64
350
81
11050
124
81 2x100=200
350
Connection positionof branch duct
160
16-M4 Hole
B arrow view
(round shape type)
110
C/L124
85
157
(square-shaped type)
95
Connection positionof branch duct
80
157
213
95
160
Connection positionof fresh air intake kit
(square-shaped type)
C arrow view
(knock hole)90(round shape type)
124
183
109
25
C/L
124
802x
100=
200
(direct installation type)
ø100
20-M4Prepared hole
Connection positionof branch duct
Connection positionof branch duct
90
350
[FCQ50-140LUV14] [FCQ50-140LUV14]
[FCQ50-71LUV14] [FCQ50-71LUV14]
[FCQ50-71LUV14]
[FCQ50-71LUV14] [FCQ100-140LUV14]
[FCQ100-140LUV14]
[FCQ100-140LUV14] [FCQ100-140LUV14]
Liquid pipe connectionGas pipe connectionDrain pipe connectionTransmission wiring connectionRemote controller wiring connectionAir-outletSuction grilleCorner decoration coverDrain hose (accessory)
12345
6789
36
62.5
Note)4.
210
(Direct connection)Outdoor air intake
Ceiling
4–M4 Hole
4–M8 to M10
2
25
62.5
285
Hanging bolt
172
arrow view
3
750
4
585–660 (Ceiling opening space)
320
For h
eight
instal
lation
21145 or less
183
1
295 o
r mor
e
1500
or m
ore
55
300 or less
575
585–
660 (
Ceilin
g ope
ning s
pace
)
196
5
150
Adjus
table(
0–54
5)
45 or less
89
89
145
Note)2.
1500mm or more*
1500mm or more*
Required space
1500mm or more*
1500mm or more*575
6
700
62.5
260
533 (Hanging bolt pitch)
2500
or m
ore
From
the f
loor s
ide
100
62.5
205
(180
)
Drain connection side
Piping connection side
320
A
A
B
(Req
uired
spac
e)53
3 (H
angin
g bo
lt pitc
h)
7arrow view
700
B
30
8
*When the discharge grill is closeout, the required space is 200mm or more.
The Front
(Service space)30 or more
(Service space)30 or more
4-M8~M10Hanging bolt
(Note.2)Brand name plate
Position slit hole for taking out in piping back
(For left piping)Drain pipe connection VP20
80 80
225
275
170105
170
127
142 58
36
85 160
192102
185
10590
210
260
195
300
275
105
135
5
For h
eight
instal
lation
300 o
r mor
e(Re
quired
space
)
From t
he floo
r side
2500 o
r more
ObstacleFloor side
55
680
515
5
145 60
65
1156
0
65
135
40 50 60
912
13 15590
40
11
14
15
18 17 16
10
5
4
42
6
57
1
6
8
3
Position : Hole of wall for taking out in piping back(View from the front)
(View from the front)
o/ 45 55
80
(Hanging position)A
B
(Han
ging
p
ositi
on)
(Req
uire
d sp
ace)
(Req
uire
d sp
ace)
123456789101112131415161718
Air discharge grilleAir suction grilleAir filterGas pipe connectionLiquid pipe connection Drain pipe connectionEarth terminal (inside the electric components box)(M4)Suspension bracketBackward pipe and wiring connection opening lidUpward pipe and wiring connection opening lidRight side pipe connection Left back drain pipe connection Left side drain pipe connection Right side drain pipe connection Hole of wall for taking out in piping back Upward drain pipe connection Upward gas pipe connection Upward liquid pipe connection
Notes:1
2
3
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. (Applies to FHQ35-71BV only)The remote control code is the standard <about 3 m outside the machine> attached.(0.5 mm2 2 wicks O.D. 5.4)(It is not attached to VRV.)
A92011201120112013601550
B96011601160116014001590
FHQ35BV1B4
FHQ71BV1B4FHQ100BV1B4
FHQ50BVV1G4FHQ60BVV1G4
FHQ125BV1B4
CEILING SUSPENDED TYPE
Liquid pipe connectionGas pipe connectionDrain pipe connectionPower supply connectionRemote control code and control wiring connectionAir discharge grilleSuction grilleDrain hose
12345
678
Notes: 1Sticking location for manufacture's label manufacture's label for indoor unit : on the bell mouth inside suction grille manufacture's label for decoration panel : on the inner frame inside suction grille2In case of using wireless remote controller, this position will be a signal receiver. refer to the drawing of wireless remote controller in detail.3When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.4Though the installation is acceptable up to maximum of 660mm square ceiling opening, keep the clearance of 45mm or less between the main unit and the ceiling opening so that the panel overlap allowance can be ensured.
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
[FHQ35-125BV]
37
DIMENSIONS (Unit: mm)
Approx.4005
65
45
4
45
Piping and Wiring intake
79.5
Approx.465
6
Mounting location
φ80 hole
114
1085
14.5
φ80 hole
Outside line
Approx.46089
35.5
Piping direction
(Req
uire
d sp
ace)
(Req
uire
d sp
ace)
120 or less
8
2500 or moreFor installation in high spaces
50 o
r mor
e30
or m
ore
(Requred space) (Requred space)1200
7
50 or more 50 or morePiping directionName plate Note)2Piping direction3
9
Approx.440
Dimensions for full open front panel
242
340
2 1
240
WALL MOUNTED TYPE
[FAQ100CVEA4]
Front panelFront grillAir outletGas pipeLiquid pipeDrain hoseEarth terminalRight side pipe connection holeLeft side pipe connection hole
123456789
Notes:1
2
3
Location of unit's of Name Plate:Right side surface of casingIn case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail.Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
(SAME AS THE INDOOR UNIT SIZE OR MORE)
Fig.AAir outlet
Inspection hatch 1(450mmX450mm)
Air inletUnit base
Control box
200
or le
ssCASE 1)
300
or m
ore
Inspection hatch
Control box
Ceiling
150
215
View
165 49
1160
245
(From the Air outlet)
7X150=1050
(All around)20-8X12 oblong hole635
1185
40
232
212
167
(467 o
r less) 3
300
7169
1
(A c
ase
with
out
the
ceilin
g)
6
2X65
=13
0
290
(Not
e.4)
300
or m
ore
4
2
28
144
700
11
700
or le
ss
5
3X65
=195
2500
or m
ore
Air outlet
Floor surface
Air inlet (Note.2)
Ceiling
Adjus
table
80
20-8X12 oblong hole
8X150=1200
1350
150
713300 or less
150 27
7
1325
12(All around)
247
(From the Air inlet)
(Ser
vice
spa
ce)
27 63140- 4.7 Hole(All around)
48- 4.7 Hole
1438
(Han
ging
bol
t pitc
h)
700 or more
(Hanging bolt pitch)
9
16X
65=
1040
(All around)8
10
19X
65=
1235
450
or m
ore
200
or le
ss14
00
(Service space)
1205
65
Air inlet
Inspection hatch 450 or more
Air outlet
200
or les
s
Control box
Inspection hatch 1(450mmX450mm)
700 or more
(SAME AS THE INDOOR UNIT SIZE OR MORE)
Inspection hatch 2
1400
or mo
re 1700
or mo
re
Control box
(SAME AS THE INDOOR UNIT SIZE +300 OR MORE)
Inspection hatch 3
700 or more
View B-2
CASE 2),3)
CeilingInspection hatch
B
20
or m
ore
Control box
View B-1
According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.
1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)
Notes: 1Location of MANUFACTURE'S LABEL: Control box surface2Mount the air filter at the suction side.(Select its colorimethod (gravity method) 50% or more.3Do not locate things should not be wet under the indoor unit.Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.4Space for Service Works
[FBQ100/125/140DV14]
Liquid pipe connectionGas pipe connectionDrain pipe connectionEarth terminal(Terminal in Control box)Control box(Inside)Remote control wiring connectionPower supply wiring and a transmission wiringAir discharge flangeAir suction flangeHangerSocket (for maintenance)Drain hose(Accessory)
1234
56
7
89101112
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
(From the Air inlet)
12
247
513
277
80
925
18-8X12 oblong hole
6X150=900
300 or less
950
150
(All around)
150
(Service space)
59
Air outlet Air inlet
Inspection hatch 450 or more
10
13X
65=
845
8
450
or m
ore 20
0 or
less
1038
(Han
ging
bol
t pitc
h)
9
65
63180
5
1000
700 or more
27(Hanging bolt pitch)
11X
65=
715
(Ser
vice
spa
ce)
30- 4.7 Hole(All around) 30- 4.7 Hole
(All around)
16-8X12 oblong hole(All around)
(From the Air outlet)
760
435
View
245
150
785
165 5X150=750
215
49
Air inlet(Note.2)
Adju
stab
le
Floor surfaceCeiling
Air outlet
700
144
167
11
212
6
169290
(467
or l
ess)
2
700
or le
ss
300
or m
ore
300
7 4
2500
or
mor
e
3
3X65
=19
5
40
(A c
ase
with
out
the
ceili
ng)
(Not
e.4)
1
28
5
232
2X65
=13
0
Ceiling
Control box
300
or m
ore
Inspection hatch
Inspection hatch 1 (450mmX450mm)
Control box
200
or le
ss
Fig.AAir outlet
Unit baseAir inlet
CASE 1)
View B-1
CASE 2),3)
Ceiling
20
or m
ore
Inspection hatch
Control box
B
Inspection hatch 2(SAME AS THE INDOOR UNIT SIZE OR MORE)
200
or le
ss10
00
or m
ore
Inspection hatch 1(450mmX450mm)
700 or more
Control box
View B-2
700 or more
1300
or
mor
e
(SAME AS THE INDOOR UNIT SIZE +300 OR MORE)
Inspection hatch 3
Control box
According to any one of below 1)~3),secure a space for service works,such as,checking and maintenance of control box,etc.
1)One inspection hatch (450X450) on the control box side and a space of 300mm or more under the unit.(Fig.A)2)One inspection hatch (450X450) on the control box side and 2 (two) inspection hatches under the unit.(Arrow View B-1)3)3 (three) inspection hatches under the unit and the control box.(Arrow View B-2)
Notes: 1Location of MANUFACTURE'S LABEL: Contro box surface2Mount the air filter at the suction side. (Select its colorimethod (gravity method) 50% or more.)3Do not locate things should not be wet under the indoor unit. Dews may drop when humidity reaches over 80%,or a drain gets stuck,or air filters are not clean.4Space for Service Works
[FBQ50/60/71DV14]
Liquid pipe connectionGas pipe connectionDrain pipe connectionEarth terminal(Terminal in Control box)Control box(Inside)Remote control wiring connectionPower supply wiring and a transmission wiringAir discharge flangeAir suction flangeHangerSocket (for maintenance)Drain hose(Accessory)
1234
56
7
89101112
38
DIMENSIONS (Unit: mm)
OUTDOOR UNIT // RKS25/35AVMG4
This model to be fixed with fixture as shown below.
In case of fixing it at the bottomIn case vibration resistance is required, fix it at both the bottom and the rear.
50 or more
1500 or more
50 or more
Required space
AB
100
C
50
Detail
0.7
Suction grille stopper
(Two both sides)
18
2-7X15 oblong hole
184 184
(For wood screw)
(Accessory)
330 30
Fixture
95
6
66
EG
68
Full open position of suction grille
H
Pull out direction of air-filter
F
D
75
KJ
L
740
or m
ore
(Pul
l out
dim
ensio
n of
air-
filter
)
50
100
Approx.46
2
1
3
5
4
200
34 223
825
600
1850
314
253
95
598
677
616
541
8
9
10
130 215126
PN
260
M
130
View
7
4- 14 Hole(For bolt)
Liquid
Handle
285
Drain outlet(I.D φ15.9 hose for connection)
8 12
550
765
Brand name label
4 - Holes for anchor bolts
63
Wiring
Service
In case of removing
196
105 16
5
Gas stop valve
22
Outdoor air thermistor
(M8 or M10)
311
13
29.5
574
490
105.5
inlet
port
( 9.5CuT)
stop valve cover
( 6.4CuT)stop valve
Indication label
Manufacture'sLabel
100
150
150
5010
0
300
50 50
50
Wall height on air outlet side =less than 1200Minimum space for air passage
FLOOR STANDING TYPE
Notes: 1Sticking location for manufacturer’s label: on the surface of cover of switch box inside the suction grille. 130
A
FVQ100/125/140CVEB450
190
B110
266
C186
350
D270
44
E45
49
F50
130
G50
190
H110
260
J180
266
K186
322
L242
79
M57
202
N144
229
P149FVQ50/60CVE4, 71CVEB4
Suction grilleAir filterThrough hole for side piping(70x90 oblong slit hole)Through hole for side piping( 80 slit hole)Through hole for side piping( 27 slit hole)Through hole for rear piping/wiring(80x130 oblong slit hole)Through hole for bottom piping/wiring(126x130 square hole)Liquid pipe connectionGas pipe connectionDrain pipe connection
123
4
5
6
7
8910
39
OUTDOOR UNIT // RKS50/60AVMG4
Wall height on air outlet side =less than 1200
100
350
100
100
350
350
50 50
50
Minimum space for air passage
4 –Holes for anchor bolts(M8 or M10)
Name plate
Brand name label
In case of removingstop valve cover
Terminal strip with earth terminal
Outdoor air temperature thermistorWiring inlet
Service port
825
155 18
30160
78
325
5801242
350
330
300
8964
10 25
735
36
Gas stop valve (o/ 12.7 CuT)
Liquid stop valve(o/ 6.4CuT)
Drain outlet(I.D. o / 15.9 hose for connection)
595
559
200
94
449
509
419
299
21Drain outlet
Drain outlet
163
112
272
479
269
Wiring inlet
Name plate
20
573.5
845
342
7
78
2030
0
300
131
326
Drain outletI.D. 18 hose for connection
Hole for anchor bolts (M8 or M10)
Liquid stop valve( 9.5CuT)
Earth terminal in switch box
Service port
Gas stop valve( 15.9CuT)
6010
5
Service port 144
OUTDOOR UNIT // RZR50/60/71LVVM4
40
41
DIMENSIONS (Unit: mm)
OUTDOOR UNIT // RZR100/125/140LUY14
30
223
5
52
13
7
6
67
55
9553
19137645
102
117
70
16
71 16
58
5
8
5
7
95
19
84
80
54
145
55
6
142
2
3
6
89
7
19
5
423
1170
4
422
9554
900
1
60 89
94
61
30
350
(345
~35
5)
43
620
320
41
140
30
140
Hole for anchorbolt 4-M12
Gas pipe connectionLiquid pipe connectionService portEarth terminalRefrigerant piping intakePower supply wiring intakeTransmission wiring intakeDrain outlet
12345678
6
5
13
52
7
55
5395
67
223
30
53
5
6
7
9580
145
19
5584
30
3835
0(3
45~
355)
320
91
37
620160
30
Hole for anchor bolt 4-M12
160
55
279
90
16
285
36
416
260
262
595
68
8 16
161
5
61
340
940
95
60
5
3
990
89
7 689
53
2
1
142
4
19
339
OUTDOOR UNIT // RZR100LVVM4
Gas pipe connectionLiquid pipe connectionService portEarth terminalRefrigerant piping intakePower supply wiring intakeTransmission wiring intakeDrain pipe connection
1
2
3
4
5
6
7
8
42
REMOTE CONTROLLER
Wired type
Staple
Remote controller
17
17
0~5
117
Remote controller
Remote controller
(Between remote controller and control box)
17
• Installation methodA Exposed body, exposed cord C Exposed body, embedded codeB Exposed body, embedded cord
Conduit
Control box
Through hole
Size
Specifications of cord
0.75~1.25 mm2
Total length 500 m
Type Shield wire (insulated thickness: 1 mm or more)Note) 1. Remote controller cord and staple are not
attached. They are field supplied parts.
120
120
17 18
42
84
38
Cord outlet hole
2823
46
• Remote controller dimensions
Wireless type
CEILING MOUNTED CASSETTE TYPE <Round Flow>• Remote controller dimensions
• Remote controller holderinstallation procedure<installation to wall surface>
• Receiver installation procedure
• Receiver detail
Transmitting part
157
62 17.5
Liquid crystalremote controller(wireless)
Remote controllerholder
CEILING MOUNTED BUILT-IN TYPEDUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
120
72 83.5
106
(Cei
ling
open
ing)
70 180.5
35 49
Service space for ceiling installation
• Receiver detail
Note :
Mor
e th
an 9
0(S
revi
ce s
pace
)
(Ceiling opening)
2-5x9 Slot
Switch box(field Supplied parts)
Do not install more than 3 receivers in the vicinity of one another.With 4 or more units, there is always the possibility of malfunction
( 12- 16)
Receiver
Drain pipingside
Refrigerantpiping side
Decoration panel
Receiver
Drain pipingside
Refrigerant piping side
Decoration panel
(BYFQ60BW1)(BYFQ60B7W1)(BYFQ60B8W1)
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE• Receiver installation procedure
WALL MOUNTED TYPE• Receiver installation procedure
• Receiver detail
BRC1C61
19
Upper case Lower case
40
2346
2848.5
4284
5X7 oblong hole
Code outlet hole
5X15 oblong hole
Lower case portion
Lower case portion
Staple
19
A Exposed cord C Embedded cord(use switch box)
B Embedded cord
84
46
Switch box for two switchex.) KJB211A(optional accessory)
Condit
19
0~5
Switch box [field supplied part]
(Between remotecontroller and control box)
48.5
19
Note)2Through hole
40
( 8- 10)
84
28
Switch box for one switchex.) KJB111A(optional accessory)
• Installation method
2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller.
Note) 1. Remote controller cord and staple are not attached. They are field
supplied parts.
Size
Specifications of cord
0.75~1.25 mm2
Total length 500 m
Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
BRC1E62
(Green)
120
120
Operationlamp
Top left outlet
Left outlet
Top centeroutlet
CEILING SUSPENDED TYPE• Receiver installation procedure
• Receiver detail
The Front
• Receiver detail
ReceiverReceiver
43
Installation service space for outdoor unit
1000
or more
300
or more
L H
L H
H
L
500
or more
100
or more
L H
For RZR50, RZR100-140LUY14
300
or more
1000 or more
200 or more
100
or more
100 or more 100 or more
100
or more
500 or more
When there are obstructions on the inlet side and both lateral sides
2. For series installation (more than two units)When there are obstructions on both sides
1. For single unit installation When there is an obstruction only on the inlet side
1. For single unit installation When there is an obstruction on the inlet side
2) When there is an obstruction in the overhead space
When there are obstructions on both sides
When there are obstructions on the inlet side and both lateral sides
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
100
or more
500 or less
1000
or m
ore
An obstruction in the overhead space
500 or less
500 or more
1000
or m
ore
An obstruction in the overhead space
500 or less
1000 or more
1000
or m
ore
An obstruction in the overhead space
150
or more
150 or more 150 or more
500 or less
1000
or m
oreAn obstruction
in the overhead space
300
or more
1000 or more
200 or more
500 or less
1000
or m
ore
An obstruction in the overhead space
1.RZR50/60/71LVVM4 2.RZR100-140LUY14
21
21
21
21
21
21
21
21
21
21
21
21
1000 or more
1) When the overhead space is open
2) When there is an obstruction in the overhead space
1) When the overhead space is open
When there is an obstruction on the inlet side1 When there is an obstruction on the outlet side2
1000
or m
ore
500 or less
250 or more150 or m
ore150 or more
500 or less
200
or more
1000 or more 250 or more 250 or more
1000
or m
ore
250 or more200
or more250 or more
1000 or more
1000
or
mor
e
100 or more
500 or less
500
or more
50 or more
500
or more
50
or more
250 or more
1000
or m
ore
500 or less
1000 or more
1000 or more
250 or more
250 or more
1000
or more
200
or more
500 or more
500 or less
1000
or m
ore
100 or more
100 or more 250 or more
1) When the overhead space is open (There is no limit to the height of the obstruction on the outlet side.)
When there are obstructions on both the inlet and outlet sides(When the obstruction on the outlet side is higher than the unit itself)
3
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
All rights reserved 06/14 SSc
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of September 2014 but subject to change without notice. Printed in Indonesia
Wisma KEIAI, 18th floorJl. Jend Sudirman Kav 3-4 Jakarta 10220 - IndonesiaTelp : +6221 572 4377Fax : +6221 572 4360website : www.daikin.co.id
Daikin Contact Center : 0800 1 081 081 - Toll Free
top related