224 Mill Street Rochester, NY 14614 p 585.442.7010 f 585.442.7019 www.seidesigngroup.com
ADDENDUM NO. 5
ROCHESTER CITY SCHOOL DISTRICT
VIRGIL I. GRISSOM – SCHOOL #7
SED Control #: 26-16-00-01-0-007-019 SED DWT #: 26-16-00-01-7-999-019
SEI Project No.: 16-3020 April 28, 2017
GENERAL INSTRUCTIONS: • Include this Addendum as part of the Construction Documents. This Addendum supplements portions of the
original Drawings and Specifications, the intent of which shall remain, except as revised herein. • Work described in this Addendum shall be in accordance with the Specifications for like items in remainder of
project and complete with all labor and materials included.
Addendum No. 5 April 28, 2017
224 Mill Street Rochester, NY 14614 p 585.442.7010 f 585.442.7019 www.seidesigngroup.com
CLARIFICATIONS:
Item AD5-1 All exterior windows within classrooms, resource rooms, offices, support rooms, and conference rooms to be included as part of Alternate No. 03, refer to details 3 and 8 on sheet A2640.
Item AD5-2 Alternate No. 02 is to include all roofing on this project, with the exception of the metal roofing.
REVISIONS TO THE PROJECT MANUAL:
SECTION 00 11 13 – Advertisement for Bids – Volume 1
Item AD5-3 REPLACE the following text to say “Sealed bids will be received until 2:00 p.m. on May 4th, 2017, at the Rochester City School District building at 1776 North Clinton Ave., Rochester, NY 14621 by the Rochester Joint Schools Construction Board (“RJSCB” or “Owner”), Attention: Pepin Accilien, Program Director, Tel. 585-512-3807, for the RCSD Virgil I. Grissom – School #7 (“Project”), at which time and place said bids will be publicly opened and read aloud. Questions during the bidding period must be communicated as described in Section 00 21 13 – INSTRUCTIONS TO BIDDERS.”
Item AD5-4 ADD the following text:
a. No Additional RFI’s will be accepted after 4/28/17 at 4pm.
SECTION 00 21 13 – Instructions to Bidders – Volume 1
Item AD5-5 DELETE the following text:
a. “The submission of a bid will be considered as evidence that the bidder has examined the premises an aquatinted himself/herself with present conditions under which he/she will be obligated to operate and that will affect any manner the work to be done.”
b. Since the building tours were cancelled and bidders were not able to access the building the statement in paragraph 2.01.2 of the Instructions to Bidders will be waived.
REVISIONS TO THE DRAWINGS:
DRAWING NO. A2131
Item AD5-6 REPLACE drawing in its entirety. See attachment A2131 (revision no.2 dated 04/28/17) DRAWING NO. A2133
Item AD5-7 REPLACE drawing in its entirety. See attachment A2133 (revision no.1 dated 04/28/17)
Addendum No. 5 April 28, 2017
224 Mill Street Rochester, NY 14614 p 585.442.7010 f 585.442.7019 www.seidesigngroup.com
DRAWING NO. A2160
Item AD5-8 REPLACE drawing in its entirety. See attachment A2160 (revision no.2 04/28/17) DRAWING NO. A2240
Item AD5-9 ADD callout of detail 1/A2640 to bottom sill of window type W3. Item AD5-10 ADD callout of detail 2/A2640 to bottom sill of window types W2, W5, and W4. Item AD5-11 ADD callout of detail 3/A2640 to top head of window types W2, W2A, and W3. Item AD5-12 ADD callout of detail 4/A2640 to jambs of window types W2, W2A, W3, W4, W5, and W6 Item AD5-13 ADD callout of detail 5/A2640 to bottom sill of window types W7, and W7A. Item AD5-14 ADD callout of detail 6/A2640 to head of bottom portion of window types W7, and W7A. Item AD5-15 ADD callout of detail 7/A2640 to sill of top portion of window types W7, and W7A. Item AD5-16 ADD callout of detail 8/A2640 to top head of window types W7, and W7A. Item AD5-17 ADD callout of detail 9/A2640 to jambs of window types W7 and W7A. Item AD5-18 ADD callout of section 11/A2640 to window type W6.
ATTACHMENTS: SPECIFICATIONS: NONE DRAWINGS: ARCHITECTURAL: A2131 – FIRST FLOOR REFLECTED CEILING PLAN AREA B (Revision No.2 dated 4/28/17) A2133 – SECOND FLOOR REFLECTED CEILING PLAN AREA B (Revision No.1 dated 4/28/17) A2160 – ROOF PLAN (Revision No.2 dated 4/28/17)
End of Addendum No. 5
FEC
FEC
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
FEC
CB
CB
CB
CB CB
CBCB
RP RPRPRPRPRPRP RP
9' - 4"AC1
8' - 0"AC48' - 0"
AC1
8' - 0"AC2
8' - 0"AC2
8' - 0"AC2
8' - 0"AC2
9' - 4"AC1
9' - 4"AC1
8' - 0"AC2
8' - 0"AC2
9' - 4"AC1
9' - 4"AC1
8' - 4"AC1
8' - 0"GBC1
8' - 4"AC4
8' - 0"GBC1
9' - 4"AC1
9' - 4"AC1
8' - 0"AC4
8' - 0"AC1
8' - 0"AC2
9' - 4"AC1
8' - 0"AC2 8' - 0"
AC4
8' - 0"AC1
9' - 0"AC1
8' - 0"AC2
8' - 0"AC1
9' - 4"AC3
8' - 6"WD1
8' - 0"GBC1
8' - 2"WD1
8' - 2"WD1
8' - 2"WD1
8' - 6"WD1
8' - 6"WD1
8' - 6"WD1
8' - 6"WD1
8' - 6"WD1
8' - 0"GBC1
9' - 4"AC1
EXISTCBC1
/1 A2130 /1 A2130
9' - 0"AC1
8' - 10"AC1
9' - 2"AC1
9' - 2"AC1
9' - 2"AC1
9' - 0"AC1
8' - 10"AC1
8' - 10"AC1 9' - 2"
AC1
9' - 0"AC1
9' - 2"AC1
8' - 4"AC3
8' - 6"GBC1
8' - 6"GBC1
9' - 4"AC3
8' - 6"WD1
8' - 6"GBC1
8' - 0"GBC1
8' - 0"GBC1
8' - 0"GBC1
8' - 4"AC1
8' - 4"AC3
10' - 0" 2' - 0" 15' - 0" 2' - 0" 15' - 0" 12' - 5"
2' -
0"
8' -
0"
5' - 5" 15' - 0" 2' - 0" 15' - 0" 2' - 0" 15' - 0" 2' - 0" 10' - 0" 2' - 3"
8' - 0"GBC1
A2631
TYP.10________________
7' -
5 1/
2"
R 6' - 7 3/8"
R 5' - 3 13/16"
R 8' - 0"
R 8' - 8"
R 4' - 6"
R 6' - 6"
R 5' - 6"
R 8' - 0"
R 6' - 6"
R 8' - 0"
R 6' - 5"R 8' - 0"
R 4' - 6"
4' - 3 1/2"
4' -
2 1/
2"
5' - 11 1/2"
2' -
6 1/
2"
8' - 11 3/4"
10' -
7"
9 3/
4"
4' - 7 1/4"
3' -
9 1/
2"
6' - 0"
9' - 1"
1 3/4
"
8' - 1 1/2"
2' -
1"
1' - 10"
2"8
' - 7
3/4
"
1' - 6"
R 7' - 0 3/4"
5' -
2"
1' - 7"
27' - 11 3/4"
5' -
0 3
/4"
2' -
0"
1' - 8"
EQ5'
- 0
"EQEQ
5' -
0"
EQ
2' -
0"
7' -
0"
2' -
0"
6' - 0"
3' - 10"
4' - 2"
2' -
6"
6' -
7 3
/4"
9"
7' -
3 1/
4"
5' - 7"
8' - 3"GBC1
A2631
TYP.6________________
A2620
TYP.3________________
A2631
TYP.5________________
A2631
TYP.10________________
2' - 7"
1' - 0"
1' -
6"
1' - 0"1' - 0
"
A2631
TYP.5________________
A2620
TYP.3________________
A2620
TYP.3________________
A2620
TYP.3________________
6' -
0"
6' -
0"
6' -
0"
EXISTCBC1
9' - 4"AC3
9' - 4"AC3
7
1
1 1 1
1 1 1
1 1 1 1 1
2
22
2 2 22
2
2 2
2
REFLECTED CEILING LEGEND
NOTES:1. SYMBOLS ARE GRAPHIC REPRESENTATIONS - ALL SYMBOLS AS SHOWN MAY NOT
APPEAR ON ALL DRAWINGS. ACTUAL SIZE/SHAPE OF ELEMENT MAY VARY FROMGRAPHIC REPRESENTATION.
2. MECHANICAL, ELECTRICAL, AND PLUMBING SYMBOLS ARE SHOWN FOR REFERENCEAND COORDINATION ONLY, REFER TO APPLICABLE DRAWINGS FOR MOREINFORMATION. FINAL CEILING COORDINATION PLAN TO BE PROVIDED BY CONTRACTORAND APPROVED BY ARCHITECT.
X'-XX"
XX
2' x 2' SUSPENDED CEILING ASSEMBLY
SUSPENDED BOARD SOFFIT / CEILING
INDICATES CEILING HEIGHT ABOVEFINISHED FLOOR BELOW (REFER TOGENERAL REFLECTED CEILING NOTE 3)
AIR RETURN OR EXHAUST REGISTER / GRILLE,(REFER TO MECHANICAL DRAWINGS)
DIFFUSER (REFER TO MECHANICAL DRAWINGS)
RECESSED LIGHT FIXTURE (REFER TO ELECTRICAL DRAWINGS)
SURFACE MOUNTED LIGHT FIXTURE (REFER TO ELECTRICALDRAWINGS)
TRACK LIGHTING
INDICATES CEILING TYPE (REFER TO CEILINGTYPE LEGEND)
CEILING HUNG PENDANT LIGHT FIXTURE (REFER TOELECTRICAL DRAWINGS)
RECESSED CAN LIGHT FIXTURE (REFER TO ELECTRICALDRAWINGS)
RECESSED CHILLER BEAM (REFER TO MECHANICAL DRAWINGS)CB
RECESSED RADIANT PANEL (REFER TO MECHANICAL DRAWINGS)RP
RECESSED SKYLIGHT LIGHT DIFFUSER, FURNISHED BYSKYLIGHT MANUFACTURER
SL
MAINTAIN EXISTING CEILING HEIGHT
CEILING HEIGHT MAY VARY, REFER TOSLOPE OF STRUCTURE ABOVE
EXIST
VARIES
ACOUSTICAL PYRAMID CEILING PANEL, REFER TOSPECIFICATION
GENERAL NOTES
1. FOR GENERAL NOTES PERTAINING TO THIS SHEET, REFER TO SHEET A0002.2. FOR TYPICAL WALL AND ROOF ASSEMBLIES, REFER TO SHEET A0002.
N
© SEI design group Architects
VIRGIL I. GRISSOMSCHOOL NO. 7ADDITIONS AND ALTERATIONS
A
B
design group
en
gage
im
agin
ein
spire
SEI585.442.7010 - 224 Mill Street - Rochester, NY 14614
518.435.2467 - 187 Wolf Road. Suite 304 - Albany, NY 12205
SED Control No.
Key Plan
It is a violation of Title VIII, Article 147 of NYS Education Law for any person, unlessacting under the direction of a licensed architect, to alter any item on this
document in any way. Any licensee who alters this document is required by law toaffix his or her seal and the notation "altered by" followed by his or her signature
and a specific description of the alterations made.
SEI Project No.
Revisions
Date
4/28
/201
7 2:
36:3
9 PM
26-16-00-01-0-007-019
31 BRYAN ST.ROCHESTER, NY 14613
ROCHESTER CITY SCHOOLDISTRICT
A2131
FIRST FLOOR REFLECTEDCEILING PLAN AREA B
16-3020
ISSUED FOR BID03-21-17
1/8" = 1'-0"1 FIRST FLOOR REFLECTED CEILING PLAN - AREA B
CEILING TYPE LEGEND
AC1 24" X 24" ACOUSTICAL CEILING TILE, WHITEAC2 24" X 24" ACOUSTICAL VINYL-LAMINATED FACE CEILING TILE, WHITEAC3 24" X 24" ACOUSTICAL CEILING TILE, BLACKAC4 24" X 48" ACOUSTIC CEILING TILE, 6" PATTERN, CUSTOM COLORCBC1 EXTERIOR GRADE 3/4" CEMENT BOARD CEILING WITH DIRECT APPLIED FINISH ON
METAL FRAMING, PAINTEDGBC1 (1) LAYER 5/8" GYPSUM BOARD CEILING ON SUSPENDED METAL FRAMING SYSTEM,
PAINTEDGBC2 (1) LAYER 5/8" HIGH IMPACT GYPSUM BOARD CEILING ON SUSPENDED METAL
FRAMING SYSTEM, PAINTEDMP1 24" X 96" ROUTE AND RETURN ALUMINUM PANEL, CUSTOM COLORWD1 LINEAR PVC CEILING ON SUSPENDED METAL TRACK SYSTEM, WOOD-LOOK FINISH
CEILING PLAN KEYNOTES
1 PROVIDE ROLLER TYPE SHADE WITHIN RECESSED ALUMINUM 3-SIDED ALUMINUM PERIMETER POCKETBASIS OF DESIGN ARMSTRONG. REFER TO WINDOW HEAD DETAILS FOR ADDITIONAL INFORMATION.
2 PROVIDE RECESSED MANUAL PULL-DOWN PROJECTOR SCREEN, BASIS OF DESIGN DRAPER INC. ACCESSSERIES.
3 PROVIDE CONT. STAINLESS STEEL TRIM FROM TOP OF FREEZER/COOLER TO 6" ABOVE ADJACENTSUSPENDED CEILING. TRIM TO MATCH FREEZER/COOLER FINISH AND BE FLUSH WITH FACE OFFREEZER/COOLER. COORDINATE WITH FOOD SERVICE DRAWINGS.
4 KITCHEN HOOD, COORDINATE OPENING IN CEILING SYSTEM WITH FOOD SERVICE DRAWINGS.5 PREP AND PAINT EXISTING METAL ENCLOSURE.6 PREP AND PAINT EXISTING SOFFIT AND LINTEL.7 PROVIDE SPRAY-APPLIED FIRE RESISTIVE COATING TO ALL EXPOSED STRUCTURAL STEEL AREA OF HATCH.
CONFORM TO UL DESIGN NO. D902.
N
1 04-07-17 BID ADDENDUM NO.12 04-28-17 BID ADDENDUM NO.5
1
RD
RPRP
RP
VTR
RPRPRPRPRPRPRPRP
RP RP
CB CB
CB CBCBCB
CB CBCBCB
CB CB
RP
9' - 4"AC1
9' - 4"AC1
9' - 4"AC1
9' - 4"AC1
9' - 4"AC2
9' - 4"AC1
9' - 4"AC1
8' - 0"AC2
8' - 0"AC2
8' - 0"AC1
8' - 0"AC2
8' - 6"AC1
8' - 6"AC3
9' - 4"AC3
9' - 4"AC1
8' - 0"AC2
EXISTCBC1
8' - 0"GBC1
8' - 6"GBC1
8' - 0"AC2
/1 A2132 /1 A2132
8' - 0"GBC1 8' - 2"
WD18' - 2"WD1
8' - 0"AC2
EXISTVARIESMP1
EXISTVARIESMP1
EXISTVARIESMP1
9' - 4"AC3
8' - 6"WD1
8' - 6"WD1
8' - 6"WD1
9' - 4"AC3
8' - 6"WD1
9' - 4"AC3
8' - 4"AC1
8' - 6"AC3
6' - 8"GBC2
6' - 8"GBC2
8' - 0"AC4
8' - 0"AC4
8' - 0"AC4
6' -
0"
6' -
0"
3' - 0" 15' - 0" 2' - 0" 15' - 0"
8' - 2"AC1
8' - 4"AC1
11' -
2"
15' -
0"
2' -
0"
15' - 0" 2' - 0" 15' - 0" 12' - 5"
R 3' - 6"
6' -
0"
A2620
TYP.3________________
A2620
TYP.3________________
A2620
TYP.3________________
A2620
TYP.4________________
A2620
TYP.1________________
A2620
TYP.1________________
A2620
TYP.1________________
A2620
TYP.1________________
A2620
TYP.1________________
A2620
TYP.1________________
A2620
TYP.3________________
A2620
TYP.3________________
A26206________________
A26206________________
R 9' - 8 7/8"
R 10' - 8 7/8"
3' -
7"
3' -
11 3
/4"
4' - 9 1/4"
6' - 0 1/4"
5' - 3 1/2"
6' -
8 1/
4"
R 2' - 6"
R 8' - 0"4' - 0"
3' -
11 1/
4"
R 5' - 0"
R 8' - 6 9/16"
R 6' - 11 1/2"
2' - 11"
1' -
10 1/
4"
2' - 8 3/4"
1' - 6"
EQ5'
- 0
"EQ EQ
5' -
0"
EQ
6' - 8 1/4"
8' - 0"AC2
7' - 6"AC1
8' - 0"AC1
8' - 0"AC4
A2631
TYP.10________________
A2631
TYP.6________________
A2631
TYP.5________________
A2631
TYP.5________________
8' - 0"AC4
A2620
TYP.7________________
A2620
TYP.7________________ 8' - 0"
GBC18' - 0"GBC1
A263122________________
A2620
TYP.3________________
A2620
TYP.3________________
A2620
TYP.3________________
A2631
TYP.10________________
PROVIDEEXPANSION JOINTIN SOFFIT TRIMAND SOFFITABOVE
6' -
0"
ROUTE AND RETURN METAL PANELSOFFIT, PROVIDE SOFFIT VENTS,REFER TO ROOF DETAILS
ROUTE AND RETURN METAL PANELSOFFIT, PROVIDE SOFFIT VENTS,REFER TO ROOF DETAILS
8' - 0"AC4
8' - 0"AC4
6' -
0"
PROVIDEEXPANSION JOINTIN SOFFIT TRIMAND SOFFITABOVE
7' -
0"
7' -
1"
5' - 0"
1 1 1
1 1 1
1 1 1 1 1
1
11
1 1 11
1
1 1
1
REFLECTED CEILING LEGEND
NOTES:1. SYMBOLS ARE GRAPHIC REPRESENTATIONS - ALL SYMBOLS AS SHOWN MAY NOT
APPEAR ON ALL DRAWINGS. ACTUAL SIZE/SHAPE OF ELEMENT MAY VARY FROMGRAPHIC REPRESENTATION.
2. MECHANICAL, ELECTRICAL, AND PLUMBING SYMBOLS ARE SHOWN FOR REFERENCEAND COORDINATION ONLY, REFER TO APPLICABLE DRAWINGS FOR MOREINFORMATION. FINAL CEILING COORDINATION PLAN TO BE PROVIDED BY CONTRACTORAND APPROVED BY ARCHITECT.
X'-XX"
XX
2' x 2' SUSPENDED CEILING ASSEMBLY
SUSPENDED BOARD SOFFIT / CEILING
INDICATES CEILING HEIGHT ABOVEFINISHED FLOOR BELOW (REFER TOGENERAL REFLECTED CEILING NOTE 3)
AIR RETURN OR EXHAUST REGISTER / GRILLE,(REFER TO MECHANICAL DRAWINGS)
DIFFUSER (REFER TO MECHANICAL DRAWINGS)
RECESSED LIGHT FIXTURE (REFER TO ELECTRICAL DRAWINGS)
SURFACE MOUNTED LIGHT FIXTURE (REFER TO ELECTRICALDRAWINGS)
TRACK LIGHTING
INDICATES CEILING TYPE (REFER TO CEILINGTYPE LEGEND)
CEILING HUNG PENDANT LIGHT FIXTURE (REFER TOELECTRICAL DRAWINGS)
RECESSED CAN LIGHT FIXTURE (REFER TO ELECTRICALDRAWINGS)
RECESSED CHILLER BEAM (REFER TO MECHANICAL DRAWINGS)CB
RECESSED RADIANT PANEL (REFER TO MECHANICAL DRAWINGS)RP
RECESSED SKYLIGHT LIGHT DIFFUSER, FURNISHED BYSKYLIGHT MANUFACTURER
SL
MAINTAIN EXISTING CEILING HEIGHT
CEILING HEIGHT MAY VARY, REFER TOSLOPE OF STRUCTURE ABOVE
EXIST
VARIES
ACOUSTICAL PYRAMID CEILING PANEL, REFER TOSPECIFICATION
GENERAL NOTES
1. FOR GENERAL NOTES PERTAINING TO THIS SHEET, REFER TO SHEET A0002.2. FOR TYPICAL WALL AND ROOF ASSEMBLIES, REFER TO SHEET A0002.
N
© SEI design group Architects
VIRGIL I. GRISSOMSCHOOL NO. 7ADDITIONS AND ALTERATIONS
A
B
design group
en
gage
im
agin
ein
spire
SEI585.442.7010 - 224 Mill Street - Rochester, NY 14614
518.435.2467 - 187 Wolf Road. Suite 304 - Albany, NY 12205
SED Control No.
Key Plan
It is a violation of Title VIII, Article 147 of NYS Education Law for any person, unlessacting under the direction of a licensed architect, to alter any item on this
document in any way. Any licensee who alters this document is required by law toaffix his or her seal and the notation "altered by" followed by his or her signature
and a specific description of the alterations made.
SEI Project No.
Revisions
Date
4/28
/201
7 2:
36:5
9 PM
26-16-00-01-0-007-019
31 BRYAN ST.ROCHESTER, NY 14613
ROCHESTER CITY SCHOOLDISTRICT
A2133
SECOND FLOORREFLECTED CEILING PLAN
AREA B
16-3020
ISSUED FOR BID03-21-17
1/8" = 1'-0"1 SECOND FLOOR REFLECTED CEILING PLAN - AREA B
CEILING TYPE LEGEND
AC1 24" X 24" ACOUSTICAL CEILING TILE, WHITEAC2 24" X 24" ACOUSTICAL VINYL-LAMINATED FACE CEILING TILE, WHITEAC3 24" X 24" ACOUSTICAL CEILING TILE, BLACKAC4 24" X 48" ACOUSTIC CEILING TILE, 6" PATTERN, CUSTOM COLORCBC1 EXTERIOR GRADE 3/4" CEMENT BOARD CEILING WITH DIRECT APPLIED FINISH ON
METAL FRAMING, PAINTEDGBC1 (1) LAYER 5/8" GYPSUM BOARD CEILING ON SUSPENDED METAL FRAMING SYSTEM,
PAINTEDGBC2 (1) LAYER 5/8" HIGH IMPACT GYPSUM BOARD CEILING ON SUSPENDED METAL
FRAMING SYSTEM, PAINTEDMP1 24" X 96" ROUTE AND RETURN ALUMINUM PANEL, CUSTOM COLORWD1 LINEAR PVC CEILING ON SUSPENDED METAL TRACK SYSTEM, WOOD-LOOK FINISH
CEILING PLAN KEYNOTES
1 PROVIDE ROLLER TYPE SHADE WITHIN RECESSED ALUMINUM 3-SIDED ALUMINUM PERIMETER POCKETBASIS OF DESIGN ARMSTRONG. REFER TO WINDOW HEAD DETAILS FOR ADDITIONAL INFORMATION.
2 PROVIDE RECESSED MANUAL PULL-DOWN PROJECTOR SCREEN, BASIS OF DESIGN DRAPER INC. ACCESSSERIES.
3 PROVIDE CONT. STAINLESS STEEL TRIM FROM TOP OF FREEZER/COOLER TO 6" ABOVE ADJACENTSUSPENDED CEILING. TRIM TO MATCH FREEZER/COOLER FINISH AND BE FLUSH WITH FACE OFFREEZER/COOLER. COORDINATE WITH FOOD SERVICE DRAWINGS.
4 KITCHEN HOOD, COORDINATE OPENING IN CEILING SYSTEM WITH FOOD SERVICE DRAWINGS.5 PREP AND PAINT EXISTING METAL ENCLOSURE.6 PREP AND PAINT EXISTING SOFFIT AND LINTEL.7 PROVIDE SPRAY-APPLIED FIRE RESISTIVE COATING TO ALL EXPOSED STRUCTURAL STEEL AREA OF HATCH.
CONFORM TO UL DESIGN NO. D902.
N
1 04-28-17 BID ADDENDUM NO.5
(E) RD
RD
RD
RD
RDRD
RD
(E) RD (E) RD
(E) RD
(E) RD
(E) RD
(E) RD
RD
RD
RD
RD RD
RD
RD
RD
EF
EF
EF
EF
LPVTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
VTR
EF
LPLP
EF
EF
EF
EF
AHU
AHU
2:12
SLO
PE
2:12 SLOPE
EXISTING SHED ROOFBELOW TO REMAIN
3
A266016________________
A266012________________
A26607________________
A266013________________
A266012________________
A266012________________
A266012________________
SIM.
SIM.
SIM.
A266012________________
A266013________________
A266013________________
A266013________________
A266014________________
A266014________________
A266014________________
A266014________________
LINE OF EXISTINGROOF DECK STEP
LINE OF EXISTINGROOF DECK STEP
(E) SL
(E) RH
TUBESKYLIGHT
A26612________________
A26611________________
A26611________________
A26613________________
A266015________________
1
2 2
2 2
A26618________________
A2410
5ALT NO. 01
ALTERNATE NO. 02
4" EJ
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
55
5
5
A26608________________
A26608________________
A26608________________
A26608________________
A266010________________
A26608________________
A26615________________
A26608________________
A26605________________
A26601________________
A26602________________
A266016________________
A266016________________
A266016________________
A266016________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A2660
TYP.3________________
A26618________________
A26618________________
A2660
TYP.3________________
A2660
TYP.3________________
A26609________________
A266010________________
A26618________________
A266110________________
A266110________________
A266111________________
A266111________________
A26623________________
A26623________________
A26623________________
A26623________________
A266010________________
SIM.
SIM.
A26614________________
EJ, MATCHEXIST WIDTH
A2160
2
BELOW
1/4:
12
1/4:
12
1/4:12
1/4:12
1/4:
12
1/4:12
1/4:12
1/4:
12
1/4:
12
1/4:12
1/4:12
1/4:
12
1/4:
121/4:12
1/4:12
1/4:
12
1/4:
12
1/4:
12
1/4:12
1/8:12
1/8
:12
1/8
:12
1/8:12
1/8:121/8:12
1/8:12
1/8
:12
1/8
:12
1/8
:12
1/8:12
1/8:12
1/8:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8
:12
1/8:121/8:12
1/8:12
1/8:12
1/8:12
1/8:12
1/8:12
1/8:12
1/8:12
1/8
:12
1/8
:12
1/8:12
1/8:121/8:12
1/8:12
1/8:12
1/8
:12
1/8:12
1/8:12
1/8:
12
1/8:12
1/8:12
1/8:12
1/8:1 2
1/ 8:1 2
1/8:12
1/8:12
1/8:12
1/8:12
1/8:
12
1/8:
12
1/8
:12
1/8:12
1/8:12
A2123
1
CANOPYBELOW
ROOFLEADER TOROOF BELOW
ROOFLEADER TOROOF BELOW
7
A26606________________
A26606________________7
7A2660
6________________
A26621________________
8
910
11
A26624________________
7
7
77 7
7
7
CH
1
1
A26623________________
A26623________________
2
2
ROOF PLAN LEGEND
NOTE: SYMBOLS ARE GRAPHIC REPRESENTATIONS -ALL SYMBOLS AS SHOWN MAY NOT APPEAR ON ALL DRAWINGS.
RD
VTR
AHU
EF EXHAUST FAN, REFER TO MECH. DWGS
ROOF DRAIN, REFER TO PLUMBINGDRAWINGS
VENT THRU ROOF, PROVIDE PENETRATION PERDETAILS, REFER TO PLUMBING DRAWINGS FOREXACT SIZE AND LOCATION
ROOF HATCH
AIR HANDLING UNIT, REFER TO MECH. DWGS
INDICATES DIRECTION OF DOWNWARD SLOPE
ADDITION ROOF WITH METAL DECK: PROVIDE EPDM ROOFSYSTEM PER DETAILS. REFER TO TYPICAL ROOF ASSEMBLY "A" ONSHEET A0002.
EXISTING CONCRETE ROOF DECK: EXISTING ROOF SYSTEMTO BE REMOVED DOWN TO EXISTING ROOF DECK, PROVIDEEPDM ROOF SYSTEM PER DETAILS. REFER TO TYPICAL ROOFASSEMBLY "B" ON SHEET A0002.
EXISTING TECTUM ROOF DECK: EXISTING ROOF SYSTEM TO BEREMOVED DOWN TO EXISTING ROOF DECK, PROVIDE EPDMROOF SYSTEM PER DETAILS. REFER TO TYPICAL ROOFASSEMBLY "C" ON SHEET A0002.
ADDITION ROOF WITH METAL DECK: PROVIDE METAL STANDINGSEAM ROOF SYSTEM PER DETAILS. REFER TO TYPICAL ROOFASSEMBLY "D" ON SHEET A0002. (HATCH MATCHES DIRECTIONOF SLOPE)
RH
SKY LIGHTSL
EXISTING LOCATION(E)
A266113________________
6
1/8"
: 1'-0
"
ALTERNATE NO. 02
2
GENERAL NOTES
1. FOR GENERAL NOTES PERTAINING TO THIS SHEET, REFER TO SHEET A0002.2. FOR TYPICAL WALL AND ROOF ASSEMBLIES, REFER TO SHEET A0002.
N
© SEI design group Architects
VIRGIL I. GRISSOMSCHOOL NO. 7ADDITIONS AND ALTERATIONS
design group
en
gage
im
agin
ein
spire
SEI585.442.7010 - 224 Mill Street - Rochester, NY 14614
518.435.2467 - 187 Wolf Road. Suite 304 - Albany, NY 12205
SED Control No.
Key Plan
It is a violation of Title VIII, Article 147 of NYS Education Law for any person, unlessacting under the direction of a licensed architect, to alter any item on this
document in any way. Any licensee who alters this document is required by law toaffix his or her seal and the notation "altered by" followed by his or her signature
and a specific description of the alterations made.
SEI Project No.
Revisions
Date
4/28
/201
7 2:
52:0
7 PM
26-16-00-01-0-007-019
31 BRYAN ST.ROCHESTER, NY 14613
ROCHESTER CITY SCHOOLDISTRICT
A2160
ROOF PLAN
16-3020
ISSUED FOR BID03-21-17
3/32" = 1'-0"1 OVERALL ROOF PLAN
ROOF PLAN KEYNOTES
1 PROVIDE PRE-FORMED ROOF SCUPPER. SEE DETAIL ON SHEET 4/A2661.2 PROVIDE OPENING IN DECK. COORDINATE EXACT SIZE AND LOCATION W/ MECHANICAL DRAWINGS.3 PROVIDE PRE-FAB ALUMINUM CAGED ROOF LADDER WITH INTEGRAL PLATFORM, REFER TO DETAIL FOR
ADDITIONAL INFORMATION.4 PROVIDE ROOF INFILL PER DETAIL 11/A2660.5 EXISTING VENT HOLE THROUGH EXISTING DECK, GROUT SOLID W/ NON-SHRINK GROUT.6 EXISTING IN-WALL SCUPPER. REMOVE & REPLACE WITH SEAMLESS COPPER PAN TIED TO EXISTING LEADER.7 MECHANICAL UNIT, COORDINATE WITH MECHANICAL DRAWINGS. PROVIDE OPENING IN DECK. COORDINATE
EXACT SIZE AND LOCATION WITH MECHANICAL DRAWINGS. PROVIDE CURB AND FLASHING PER DETAILS.PROVIDE CRICKET ON HIGH SIDE, TYPICAL.
8 REMOVE EXISTING FLUE AND OUTER SLEEVE IN ITS ENTIRETY. MODIFY EXISTING ROOF PENETRATION TOACCOMODATE (2) 5" PENETRATIONS. PROVIDE RAIN CAPS W/ BIRD SCREENS. COORDINATE WITH PLUMBINGDRAWINGS.
9 REMOVE FLUE OUTER SLEEVE IN ITS ENTIRETY, EXISTING FLUE TO REMAIN. PROVIDE METAL LINER EXTENSION,REFER TO DETAIL. PROVIDE RAIN CAP W/ BIRD SCREEN. COORDINATE WITH MECHANICAL DRAWINGS.
10 PROVIDE GALV. STEEL PLATE, MATCH SIZE OF EXISTING CHIMNEY, ANCHOR TO EXISTING CHIMNEY, REFER TOSTACK DETAIL. PROVIDE BLOCKING AND INSULATION REQUIRED TO BUILD UP FLUSH W/ ADJACENTINSULATION LEVEL.
11 PROVIDE SMOKE HATCH SIMILAR TO EXISTING.
N
N
1/4" = 1'-0"2 ROTUNDA CANOPY ROOF PLAN
1 04-07-17 BID ADDENDUM NO.12 04-28-17 BID ADDENDUM NO.5