4th April 2006 1

MICEMICE – –

Magnetic Shield ConfigurationMagnetic Shield Configuration

H Witte, J Cobb

Oxford University

University of Oxford, Clarendon Laboratory, Parks Road, Oxford, OX1 3PU, UK

4th April 2006 2

MICE – Magnetic Shields

• Dimensions– 1st shield:

ID=500mm, OD=1500mm, t=100mm

– 2nd shield: 120 mm downstream from 1st shield, ID=600mm, OD=1800mm, t=20mm

– 3rd shield: 100mm downstream from 2nd shield, ID = 660mm, OD=1800mm, t=10mm

• Inner radius of shields– John Cobb’s estimate

End

Coi

l 2

4th April 2006 3

Magnetic Shields – Inner Radius

4th April 2006 4

Forces on Shields

Force [N] Force [N]10 mm shift

Force [N]20 mm shift

Force [N]rinner, 1st shield = 220 mm

1st shield 6e4 6.45e4 6.9e4 6.61e4

2nd shield 6.9e3 6.77e3 7.2e3 7e3

3rd shield -80 -220 -200 -94

The forces are not a concern

Note: Shifts refer to all coils being moved towards end coil no. 2

4th April 2006 5

Nomenclature

• Z: Symmetry axis of MICE

• R: direction orthogonal to Z (radius)

• dz: used in the plots for different points in z between two shields. Point of reference is always the shield closest to the middle of MICE (i.e. z=0). – Example: plot of field between 1st and 2nd shield

dz=20 means 20 mm downstream from 1st shield

• Units: SI (T, m, N), unless stated otherwise

4th April 2006 6

Fields between 1st and 2nd shield

4th April 2006 7

Fields between 1st and 2nd shield

4th April 2006 8

Fields between 2nd and 3rd shield

4th April 2006 9

Fields between 2nd and 3rd shield

4th April 2006 10

Fields after 3rd shield

4th April 2006 11

Fields after 3rd shield

4th April 2006 12

4th Shield?

• 100 mm downstream from 3rd shield

• ID=0.72, OD=1.8, t=0.01

4th April 2006 13

Field between 3rd and 4th Shield

4th April 2006 14

Field after 4th Shield

4th April 2006 15

Field after 4th Shield

4th April 2006 16

1st Shield with smaller inner radius

4th April 2006 17

1st Shield with smaller inner radius – Comparison

4th April 2006 18

(Some) Conclusions

• Good field region for TOF2 starts at r=38 cm (40 mm from shield 1)

• Field between 2nd and 3rd shield looks good

• Reducing the inner radius of 1st shield may help to increase good field region for TOF2 – Works if PMT’s really close to 1st shield

• Open questions:– Minimum inner radius 1st/2nd/3rd shield?