344 Bloor Street W, Suite 607, Toronto, ON Canada M5S 3A7
www.lprglobal.com | www.uskoreahotlink.com
Tel.: +1 416-423-5590
E-Mail: info@lprglobal.com
Contents Page
Turbo Compressor Distillers 3
Evaporation Technology 4
Turbo VCD & MVR Features 5 - 6
Turbo MVR Specifications 7
Turbo VCD Specifications 8
Accredited Performance 9 - 10
Certifications 11
H i g h P u r i t y Wa t e r
Tu r b o Va p o r C o m p r e s s i o n D i s t i l l e r
Energy Efficient Distiller Systems
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
3
DHP Engineering’s Packaged Vapor Compression Distillers (VCD) and Mechanical Vapor Recompression (MVR)
systems are used for the distillation of sea water, brackish water, contaminated ground water, and waste water
through an effective heat pump system. Compression distillers are a simple and efficient method of producing a
constant supply of high quality fresh water with only minimal power consumption. The evaporation technologies in
our packaged vapor compression distillers utilize a specially designed turbo compressor for energy efficient
production of high purity water for drinking or for reusing in industrial applications.
Turbo Compressor Distillers
Main Components
The main components of a vapor compression distiller or mechanical vapor recompression distiller include an
evaporation tank, condensation tank, plate-type main heat exchanger, turbo steam compressor, circulation
pump, secondary heat exchangers, electric heater, pumps for condensed/concentrated/raw water, equipment
controller, monitor gauges, and operation control panel.
Detailed View
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
4
Energy Recovery VCD System
Our goal is to create pure, high-quality water for drinking or industrial process while using minimal energy.
This is accomplished through developing technologies through practical research over a period of 10 years
into heat recovery systems and high speed turbo machinery. An efficient energy recovery system results in
energy savings and lower operating costs. Our Vapor Compression Distillers or Mechanical Vapor
Recompression Distillers are much more efficient at distilling sea water or waste water than traditional single
stage multiple-effect distillation processes.
Turbo Compressor Distiller
(VCD & MVR)Multiple-Effect Distillation (MED)Single Stage Distiller
Waste Water TreatmentCoefficient of
Performance (COP)Cost Per Ton (USD $) Remarks
Single Stage 0.80 – 0.82 50 – 60 Wastewater consignment cost:
USD $80-100 Per Ton
(Korea Institute of Energy
Research Resources)
2 Stage 1.64 – 1.68 40 – 50
Single TVR 2.01 – 2.06 30 – 40
Single VCD 25.40 – 25.80 1 – 5
Evaporation Technology
Methods Single Stage 2 Stage ~ 10 Stage VCD
Input Energy (kWh/ton) 720 360 ~ 72 23
620 kcal/ℓ
20 kcal/ℓ
* Coefficient of Performance (COP) = 620 (kcal) / 20 (kcal) = 31
VCD Waste Water Treatment Performance
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
5
Features & Advantages
• High Quality Fresh Water
• Simple & Compact Design for Installation & Maintenance
• Portable (suitable for standard 20’ high cube container)
• Easy Access for Maintenance
• Fully Automatic PLC-controlled Operation
• Easy Monitoring System
• Freshwater Control System
• Reliability, Long Operating Life, Low Operating Cost
• Titanium Plate Heat Exchanger and Durable Resistant
Materials (Stainless Steel Tanks)
• Best Coefficient of Performance (COP > 20)
• Low Specific Energy Consumption
• Direct-Drive Oil Pump for Reliable Lubrication of Gears
and Bearings
• No Ejector, No High Pressure Pump, No Booster Pump
for Desalinated Water
• Small Turbo Compressor Impeller
• Lower Noise (below 82dB)
Benefits Over Reverse Osmosis (RO) Water Treatment
Systems
• Fewer Periodic Consumables
• No Filter Replacement Required
• No Chemicals for Pre-Treatment (Chemical Dosing,
Sterilization, Pre- & Post-Water Treatment Facilities
• No Problem for Brine Disposal (Compatible with ZLD
Technology)
• Simple System
Turbo VCD & MVR Features
VCD for Waste Water Treatment
Multi-Purpose: Effective for all types of non-volatile malignant waste water.
Reduces Operating Costs: There is no need for periodic replacement of parts, no use of chemicals, and
complete sterilization with high temperature.
Versatile: Is suitable for smaller treatment demands and there are no special requirements for pre- or post-
water treatment systems resulting in small footprint and minimal space requirements for installation and
maintenance.
Real-Time Monitoring
Touch Screen Control Panel (PLC)
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
6
Turbo VCD & MVR Features
Optimized Maintenance & Service AreaS
erv
ice
Are
a
Se
rvic
e A
rea
3250.0
Service Area
Service Area
MVR for Contaminated Water (Industrial Processes)VCD for Sea Water (Desalination)
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
7
Turbo MVR Specifications
Turbo Mechanical Vapor Compression Distiller
*20ft High Cube Container
Tiling-Up Turbo MVR
Mobile Compression Distiller
ModelCapacity
(m3/day) (ton/day)
Dimension (m) Weight
(ton)L W H
ADR25 25 6.0 2.5 2.9 10
ADR50 50 6.0 2.5 2.9 13
ADR75 75 6.0 2.5 2.9 15
ADR100 100 6.0 2.5 2.9 17
ADR200 200 6.0 2.5 2.9 30
ModelCapacity
(m3/day) (ton/day)
Dimension (m) Weight
(ton)L W H
ADR300 300 6.0 2.5*3 2.9 17*3
ADR500 500 6.0 2.5*5 2.9 17*5
ADR1000 1000 6.0 2.5*10 2.9 17*10
*Depending on the required capacity, additional MVR distillation units can be combined or additional MVR
units can be added in the future to meet increasing water consumption requirements.
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
8
Turbo VCD Specifications
Vapor Compression Distiller Specifications
VCD30 VCD50 VCD75
Dimensions (m) 3.00*2.15*2.40 3.25*2.15*2.40 3.40*2.15*2.40
Dry Weight (ton) 4.0 4.5 5.0
Capacity (ton/day) 30 50 75
Power Consumption (kWh/ton) ~30 ~30 ~30
Fresh Water Quality (ppm) ~5 ~5 ~5
Turbo Steam Compressor
- Type
- Evaporation Capacity
- RPM
- Centrifugal
- 1250 kg/hr
- 22500
- Centrifugal
- 2100 kg/hr
- 22500
- Centrifugal
- 3125 kg/hr
- 22500
Heat Exchangers
- Type
- Material
- Plate
- Titanium
- Plate
- Titanium
- Plate
- Titanium
Turbo Steam CompressorVapor Compression Distiller
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
9
Accredited Performance
Reliable & Energy Efficient
As a result of extensive experience in developing compression distillation systems, our Turbo VCD and MVR
systems are very reliable and energy efficient. Our systems have been tested by the Korea Institute of Energy
Research to confirm our in-house testing for energy efficiency and also by the Korea Chemical Test Institute for
chemical analysis of the treated waste water ensuring high quality pure water.
Some past clients include Daewoo Shipbuilding & Marine Engineering (DSME), Hyundai Heavy Industry (HHI),
Hyundai Cement Co, Namhae Chemical Corporation, and Busan Environmental Corporation.
*Accredited test from Korea Institute of Energy Research
Description Self Test Accredited
Total Test time (Hr) 1,444 8.53
Avg. Water Temp. (°C) 20 21.3
Avg. Steam Temperature (°C) 100 99.8
Avg. Freshwater Flow (Liter/hr) 1,000 1,007.8
Avg. Compressor Power (kW) 23 21.0
Accumulated water (Liter) 1,444,700 8.597
Total Power (kWh) 43,584 244
Based on Compressor (COP) 31.3 31.2
VCD (COP) 23.9 23.8
Power Consumption (Wh/Liter) 30.2 30.1
Energy Efficiency Ratio (%) 95.8 95.8
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
10
Accredited Performance
Plating Factory Malignant Waste Water Treatment (Ansan City, Korea)
Influx Waste Water: 90tons/day, TDS 10,000ppm
Efflux Condensate Clean Water: 81tons/day, TDS 48ppm
Efflux Concentrated Waste Water: 9tons/day, TDS 90,000ppm
Total Volume Reduction Ratio: 1:10
Treatment of Condensate Water: Below $5,000 KRW/ton ($4 USD/ton)
Units
Disposal Regulation Limit (Korea)Sampling: May 2008
Korea Chemical Test Institute
Clean “A” “B” “C” Influx EffluxTreat
(%)
BOD mg/ℓ 40 80 120 30 79.4 9.1 88.5
CODMn mg/ℓ 50 90 130 40 484 28.3 94.2
SS mg/ℓ 40 80 120 30 186 2.0 98.9
T-N mg/ℓ 30 60 60 60 504 6.01 98.8
T-P mg/ℓ 4 8 8 8 0.85 0.05 94.1
CN- mg/ℓ 0.2 1 1 1 ND ND
Cr mg/ℓ 0.5 2 2 2 1.42 0.02 98.6
Fe mg/ℓ 2 10 10 10 62.2 0.14 99.8
Zn mg/ℓ 1 5 5 5 183 0.11 99.9
Cu mg/ℓ 1 3 3 3 0.07 0.03 57.1
pH - 5.8 ~ 8.6 5.8 ~ 8.6 5.8 ~ 8.6 5.8 ~ 8.6 5.7 6.8
Conductivity ㎲/cm Reference 24,700 57 99.8
Na mg/ℓ Reference 5,180 1.77 100.0
Ni mg/ℓ Reference 1.41 0.02 98.6
TDS mg/ℓ Reference 16,300 48.0 99.7
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/
http://www.uskoreahotlink.com/products/epc/packaged-wastewater-treatment-vcd/ 11
Certifications
LPR Global, Inc.344 Bloor Street W, Suite #607 Toronto, ON M5S 3A7 Canada
www.lprglobal.com | www.uskoreahotlink.com
Tel: +1 416-423-5590
E-Mail: info@lprglobal.com