© 2006 Hitachi Data Systems
RAID Concepts
A. Ian Vogelesang
Tools Competency Center (TCC)
Hitachi Data Systems
Hitachi Data System’s WebTech Series
2© 2006 Hitachi Data Systems
• RAID Concepts• Who should attend:
– Systems and Storage Administrators
– Storage Specialists & Consultants
– IT Team Lead
– System and Network Architects
– IT Staff
– Operations and IT Managers
– Others who are looking for storage management techniques
Hitachi Data Systems WebTech Educational Seminar Series
3© 2006 Hitachi Data Systems
How RAID type impacts cost
• The factors we will examine– Disk drive capacity vs. disk drive IOPS capability
– The impact of RAID level on disk drive activity
• Topics to cover along the way– RAID concepts (RAID-1 vs. RAID-5 vs. RAID-6).
– The 30-second “elevator pitch” on data flow through the subsystem.
• Conclusion will be – That I/O access pattern very often is the determining factor, rather
than storage capacity in GB.
4© 2006 Hitachi Data Systems
Growth in recording density drives $/GB
60 70 80 90 100 110Production Year
1E-3
1E-2
1E-1
1E+0
1E+1
1E+2
1E+3
1E+4
1E+5
1E+6
Are
al D
ensi
ty M
egab
its/
in2
1st MR Head
1st GMR Head
2000 10
60% CGR
100% CGR
40% /yr ArealDensityProgress
PerpendicularRecording
105
104
103
102
106
10
1
10-1
10-2
10-3
25% CGR
IBM RAMAC (First Hard Disk Drive)
5© 2006 Hitachi Data Systems
Time
Are
al D
ens
ity
(Gb
/in2
) Longitudinal
Perpendicular
Bit Patterned Media
Thermally-assisted writing
100-130
500-800
1,500-4,000
2,000-15,000
10,000 Gb/in2 = 10 Tb/in2
50 TB 3.5-inch drive12 TB 2.5-inch drive
1 TB 1-inch drive
2006 2011 2014
~ 60 M fold increase
50 Years > 50 Million increase in areal density
Areal density growth will continue
6© 2006 Hitachi Data Systems
Here’s the problem
• Drive capacities keep doubling every 1.5 years or so• If you take the data that used to be on two disk drives and put it
onto one drive that’s twice as big, you will also be combining the I/O activity that was on the original two drives onto the one double-size drive.
• The problem is that as drive capacity keeps increasing, the number of I/Os per second (IOPS) that a drive can handle has not been increasing.
– An I/O operation consists of a seek, ½ turn latency, and data transfer.
– Data transfer for a 4K block is now down to around 1 % of a rotation.
– To position the head takes over 1 rotation (seek + ½ turn latency)
– IOPS capability is ALL about mechanical positioning
7© 2006 Hitachi Data Systems
IOPS capability at 50% busy by drive type
63 65 65
86 86
38
59 61 61
81 81
23*
0
10
20
30
40
50
60
70
80
90
100
10K73 10K146 10K300 15K73 15K146 SATA7K400
Read
Write
* Includes read verify after write
• Note that IOPS capability is the same for different drive capacities with same RPM
• These are green zonegreen zone upper limits per drive for back-end I/O, including RAID-penalty I/Os
4k random IOPS at 50% busy by drive type
8© 2006 Hitachi Data Systems
Access density capability
• When we talked about combining the data that used to be on two drives onto one double-size drive, and how that also combines (doubles) the I/O activity to the bigger drive, this illustrates that for a given workload there is a certain amount of I/O activity per GB of data.
• This activity per GB is called the “access density” of the workload, and is measured in IOPS per GB.
• Over the last few decades, as disk drive storage capacity has become much cheaper, from a humble beginning it became economic to store graphics, then audio, and now video.
– The introduction of these new data types has reduced typical access densities by about a factor of 10 over the last 20 years.
• However, access density is going down slower than disk drive capacity is going up.
– Typical access densities are reported in the 0.6 to 1.0 IOPS per GB range
9© 2006 Hitachi Data Systems
Random read IOPS capability by drive type
• This chart shows what access density each drive type can handle if you fill it up with data.
marks green zone upper limit at 50% busy.
• The position of the left to right shows the maximum access density that the drive can comfortably handle.
Random read response by access density
0
5
10
15
20
25
30
35
40
45
50
00.
10.
20.
30.
40.
50.
60.
70.
80.
9 11.
11.
21.
3
Access Density, IOPS/GB
Res
po
nse
Tim
e, m
s
7200
10K15K
7K400 10K300 15K300 10K146
10K73
15K73
15K146
10© 2006 Hitachi Data Systems
RAID makes the access density problem worse
• The basic idea behind RAID is to make sure that you don’t lose any data when a single drive fails.
• So what this means is that whenever a host writes data to the subsystem, that at least two disks need to be updated.
• The amount of extra disk drive I/O activity needed to handle write activity is the key factor in determining the lowest cost solution as a combination of disk drive RPM, disk drive capacity, and RAID type.
– So that’s why we will look at how different RAID levels work
• It is very rare that the access density is so low that you can completely fill up the cheapest drive.
– Only for things like a home PVR will a 750 GB SATA drive make the smallest dent in your wallet while getting the job done.
11© 2006 Hitachi Data Systems
30 second “elevator pitch” on subsystem data flow
• Random read hits are stripped off by cache and do not reach the back end.• Random read misses go through cache unaltered and go straight to the
appropriate back end disk drive.– This is the only type of “I/O” operation where the host always “sees” the
performance of the back-end disk drive.
• Random writes– Host sees random writes complete at electronic speed
• Host only sees delay if too many pending writes build up.– Each host random write is transformed going through cache into a multiple I/O
pattern that depends on RAID type
• Sequential I/O– Host sequential I/O is at electronic speed.– Cache acts like a “holding tank”.– Back end puts [removes] “back-end buckets” of data into [out of] the tank to
keep the tank at an appropriate level
12© 2006 Hitachi Data Systems
What is RAID?
• 1993 paper by a group of researchers at UC Berkeley– http://www.eecs.berkeley.edu/Pubs/TechRpts/1993/CSD-93-778.pdf
• “Redundant Array of Inexpensive Disks”– The original idea was to use cheap (i.e. PC) disk drives arranged in a
RAID to give you “mainframe” reliability.
– Now most call it Redundant Array of Independent Disks
• A RAID is an arrangement of data on disk drives in such a way that if a disk drive fails, you can still get the data back somehow from the remaining disks
– RAID-1 is mirroring – just keep two copies
– RAID-5 uses parity – recovers from single drive failures
– RAID-6 uses dual parity – recovers from double drive failures
13© 2006 Hitachi Data Systems
RAID-1 random reads / writes
• Also called “mirroring”
• Two copies of the data
• Requires 2x number of disk drives
ABC ABC
Copy #1 Copy #2
XYZ XYZ
Copy #1 Copy #2
or
• For reads, the data can be read from either disk drive
• Read activity distributed over both copies reduces disk drive busy (due to reads) to ½ of what it would be to read from a single (non-RAID) disk drive
Copy #1 Copy #2
XYZ
• For writes, a copy must be written to both disk drives
• Two parity group disk drive writes for every host write
• Don’t care about what the previous data was, just over-write with new data
14© 2006 Hitachi Data Systems
RAID-1 sequential read
• 2 sets of parallel I/O operations, each set reading 4 data chunks (2 MB)• Parity group data MB/s = 4 x drive MB/s
Chunk 1 Chunk 2 Chunk 3 Chunk 4
Chunk 5 Chunk 6 Chunk 7 Chunk 8
Chunk 1’Chunk 1 Chunk 2 Chunk 2’
Chunk 3Chunk 3’ Chunk 4’ Chunk 4
Chunk 5’Chunk 5 Chunk 6 Chunk 6’
Chunk 7Chunk 7’ Chunk 8’ Chunk 8
2+2 shown
15© 2006 Hitachi Data Systems
RAID-1 sequential write
• 4 sets of parallel I/O operations, each writing 2 data chunks (1MB) and 2 parity chunks• Parity group data MB/s = 2 x drive MB/s
Chunk 1 Chunk 2 Chunk 3 Chunk 4
Chunk 5 Chunk 6 Chunk 7 Chunk 8
Chunk 1’Chunk 1 Chunk 2 Chunk 2’
Chunk 3Chunk 3’ Chunk 4’ Chunk 4
Chunk 5’Chunk 5 Chunk 6 Chunk 6’
Chunk 7Chunk 7’ Chunk 8’ Chunk 8
2+2 shown
16© 2006 Hitachi Data Systems
RAID-1 comments
• Since RAID-1 requires doubling the number of disk drives to store the data, people tend to think of RAID-1 as the most expensive type of RAID.
• However, due to the intensity of host access, in RAID subsystems often one cannot completely “fill up” the disk drive with data because the disk drive would become too busy.
• RAID-1 offers the lowest “RAID penalty” of only having two disk drive I/Os per random write, compared to four for RAID-5, and six for RAID-6.
• For this reason, when the workload is sufficiently active and has a lot of random writes, RAID-1 will be the cheapest RAID type because it has the least disk drive I/O operations per random write.
17© 2006 Hitachi Data Systems
RAID-1’s “RAID penalty”
• Penalty in space– Double the number of disk drives required
• Penalty in disk drive utilization (disk drive % busy)– Twice the number of I/O operations required for all writes
– No penalty for read operations; read operation distributed over twice the number of drives.
18© 2006 Hitachi Data Systems
RAID-5 parity concept
• Each parity bit indicates whether or not there is an odd number of “1” bits in that bit position across the whole parity group (“odd parity”).
• If you add more data drives, you don’t add any more parity.
10011 11111 00000 01100
Data Data Data (odd)parity
0 XOR 1 XOR 0 = 1 There is an odd number of 1s in this bit position, so parity bit is 1
1 XOR 1 XOR 0 = 0 With an even number of 1s in this bit position, parity bit is set to 0.
19© 2006 Hitachi Data Systems
RAID-5 – if drive containing parity fails
• You still have the data.• Better reconstruct the parity on a spare disk drive
right away just in case a second drive fails
10011 11111 00000 01100
Data Data Data Parity
20© 2006 Hitachi Data Systems
RAID-5 – if drive containing data fails
• If a drive that had data on it fails, you can reconstruct the missing data.• Read the corresponding “chunk” from all the remaining data drives, and see how
many “1” bits there are in each position.• By comparing how many “1” bits there are in each bit position out of the remaining
disk drives with what the parity tells you there originally was, you can reconstruct the data
• Better reconstruct the parity on a spare disk drive right away just in case a second drive fails
10011 11111 00000 01100
Data Data Data ParityA “1” bit here says there
originally was an odd number of “1” data bits in this position across
the data drives
Since on the remaining data disks, there is now an even
number of “1” bits, we know that the missing data bit is a “1”`
11111
21© 2006 Hitachi Data Systems
RAID-5 random read hit
• Read hits operate at electronic speed
• Just transfer data from cache
10011 11111 00000 01100
Data #1 Data #2 Data #3 Parity
Cache00000
Copy of data #3
Read data #3
22© 2006 Hitachi Data Systems
RAID-5 random read miss
• Read misses are the ONLY operation that “sees” the speed of the disk drive during normal (not overloaded) operation
• I.e. read misses are the only type of host I/O operation that does not complete at electronic speed with just an access to cache
10011 11111 00000 01100
Data #1 Data #2 Data #3 Parity
Cache
10011
00000
Copy of data #1
Copy of data #3
Read data #1
23© 2006 Hitachi Data Systems
RAID-5 random write
1) Read old data, read old parity
2) Remove old data from old parity giving “partial parity” (parity for the rest of the row)
3) Add new data into partial parity to generate “new parity”
4) Write new data and new parity to disk
10011 11111 00000 01100
Data #1 Data #2 Data #3 Parity
01100
11111
..........
Olddata
Old parity
1100101010
Newdata
Cache
- 10011Partial parity
New parity
11001+
New data
01010New data
#2 from host
Partial parity corresponds to
remaining part of stripe without old
data
24© 2006 Hitachi Data Systems
RAID-5 sequential read
• The subsystem “detects” that the host is reading sequentially after a few sequential I/Os
– (The first few are treated as random reads.)
• The subsystem performs “sequential pre-fetch” to load stripes of data from the parity group into cache in advance of when the host will request the data
• The subsystem can usually easily keep up with the host as transfers from the parity group are performed in parallel
110110100011001111
Cache
10101 00110 10101
10101 00110 10101 11001
11001
25© 2006 Hitachi Data Systems
RAID-5 sequential read example
• In parallel, read a chunk from each drive in the parity group.• 3 sets of parallel I/O operations to read 12 chunks (6 MB)• Parity group MB/s = 4 x drive MB/s
Parity 7, 8, 9
Parity 4, 5, 6
Parity 1, 2, 3
Parity 10, 11, 12
Chunk 1 Chunk 2 Chunk 3 Chunk 4
Chunk 1 Chunk 2 Chunk 3
Chunk 4
Chunk 5 Chunk 6 Chunk 7 Chunk 8
Chunk 5 Chunk 6
Chunk 7 Chunk 8
Chunk 9 Chunk 10 Chunk 11 Chunk 12
Chunk 9
Chunk 10 Chunk 11 Chunk 12
26© 2006 Hitachi Data Systems
RAID-5 sequential write
• First compute the parity chunk for a row• Then write row to disk.• 4 sets of parallel I/O operations to write 12 data chunks (6 MB) with 4 parity chunks• Parity group data MB/s = 3 x drive MB/s
Chunk 1 Chunk 2 Chunk 3
Parity 1, 2, 3
Chunk 1 Chunk 2 Chunk 3 Parity 1, 2, 3
Chunk 4
Chunk 5 Chunk 6
Parity 4, 5, 6
Parity 4, 5, 6 Chunk 4Chunk 5 Chunk 6
Chunk 8Chunk 7
Chunk 9
Parity 7, 8, 9
Parity 7, 8, 9 Chunk 7 Chunk 8Chunk 9
Chunk 10 Chunk 11 Chunk 12
Parity 10, 11, 12
Parity 10, 11, 12 Chunk 10 Chunk 11 Chunk 12
27© 2006 Hitachi Data Systems
RAID-5 comments
• For sequential reads and writes, RAID-5 is very good.
– It’s very space efficient (smallest space for parity), and sequential reads and
writes are efficient, since they operate on whole stripes.
• For low access density (light activity), RAID-5 is very good.
– The 4x RAID-5 write penalty is (nearly) invisible to the host, because it’s non-
synchronous.
• For workloads with higher access density and more random writes, RAID-5
can be throughput-limited due to all the extra parity group I/O operations to
handle the RAID-5 “write penalty”
28© 2006 Hitachi Data Systems
RAID-5 “RAID penalty”
• Penalty in space– For 3+1, 33% extra space for parity
– For 7+1, 14% extra space for parity
• Penalty in disk drive utilization (disk drive % busy)– Random writes
• Four times the number of I/O operations (300% extra I/Os)
– Sequential writes
• For 3+1, 33% extra I/Os for sequential writes
• For 7+1, 14% extra I/Os for sequential writes
29© 2006 Hitachi Data Systems
RAID-6
• RAID-6 is an extension of the RAID-5 concept which uses two separate parity-type fields usually called “P” and “Q”.
• The mathematics are beyond a basic course*, but RAID-6 allows data to be reconstructed from the remaining drives in a parity group when any one or two drives have failed.*The math is the same as for ECC used to correct errors in DRAM memory or on the surface of disk drives.
• Each RAID-6 host random write turns into 6 parity group I/O operations– Read old data, read old P, read old Q– (Compute new P, Q)– Write new data, write new P, write new Q
• RAID-6 parity group sizes usually start at 6+2.– This has the same space efficiency as RAID-5 3+1.
D1 D2 D3 D4 D5 D6 P Q
“6D + 2P” parity group
30© 2006 Hitachi Data Systems
RAID-6 “RAID penalty”
• 6+2 penalty in space– 33% extra space for parity
• 6+2 penalty in disk drive utilization (disk drive % busy)– Random writes
• Six times the number of I/O operations(500% extra I/Os)
– Sequential writes
• 33% extra I/Os
31© 2006 Hitachi Data Systems
RAID-1 vs RAID-5 vs RAID-6 summary
• The concept of RAID with parity groups permits data to be recovered even upon a single drive failure for RAID-1 and RAID-5, or a double drive failure for RAID-6
• RAID-1 trades off more space utilization for lower RAID penalty for writes, and lower degradation after drive failure.
– RAID-1 can be cheaper (require less disk drives) than RAID-5 where there is concentrated random write activity
• RAID-5 achieves redundancy with less parity space overhead, but at the expense of having a higher “RAID penalty” for random writes, and having a larger performance degradation upon a drive failure
32© 2006 Hitachi Data Systems
30 second “elevator pitch” on subsystem data flow
• Random read hits are stripped off by cache and do not reach the back end.• Random read misses go through cache unaltered and go straight to the
appropriate back end disk drive.– This is the only type of “I/O” operation where the host always “sees” the
performance of the back-end disk drive.
• Random writes– Host sees random writes complete at electronic speed
• Host only sees delay if too many pending writes build up.– Each host random write is transformed going through cache into a multiple I/O
pattern that depends on RAID type
• Sequential I/O– Host sequential I/O is at electronic speed.– Cache acts like a “holding tank”.– Back end puts [removes] “back-end buckets” of data into [out of] the tank to
keep the tank at an appropriate level
33© 2006 Hitachi Data Systems
RAID-5 can often be more expensive
• See how much busier the “back end” disk drives are for the RAID-5 configuration, all due to random writes (solid blue)
• In this case, the RAID-1 configuration was cheaper, because fewer disk drives were needed to handle the back-end I/O activity.
• RAID-1 drives could be completely filled, whereas the RAID-5 drives could only be filled to 55% of their capacity.
34© 2006 Hitachi Data Systems
Conclusions – factors driving lowest cost
• The lowest cost configuration in terms of disk drive RPM, disk drive
capacity, and RAID type depends strongly on the access density
and the read:write ratio.
• If there is even moderate access density with significant random
write activity, RAID-1 will often turn out to be the lowest cost total
solution, due to being able to fill up more of the drives’ capacity with
data.
• Where access densities are higher, 15K RPM drives will often turn
out to offer the lowest cost overall solution.
• SATA drives, due to their low IOPS capability, can only be filled if
the data has very low access density, and therefore are rarely the
cheapest.
35© 2006 Hitachi Data Systems
Upcoming WebTech Sessions:
• 19 September - Enterprise Data Replication Architectures that Work: Overview and Perspectives
• 17 October – 10 Steps To Determine if SANs Are Right For You
www.hds.com/webtech
© 2006 Hitachi Data Systems
Questions/Discussion