Jo House
5/16/2019
Amoozemeter Field Demonstration for Determining Landfill Clay Liner Hydraulic Conductivity
![Page 2: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/2.jpg)
• LANDFILL LINER REQUIREMENTS:
• A MINIMUM OF THREE FEET IN THICKNESS, AND
• SHALL BE CONSTRUCTED/COMPACTED WITH SOILS WITH A MAXIMUM HYDRAULIC CONDUCTIVITY OF 1 X 10-7 CM/SEC
SOLID WASTE REGULATIONS PROMULGATED
IN MARCH 1990
![Page 3: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/3.jpg)
• INABILITY OF SHELBY TUBE TO CAPTURE SUFFICIENT SOIL FOR LAB HYDRAULIC CONDUCTIVITY TESTING
• GRAVEL /ROCK CAN BEND THE END OF THE SHELBY TUBE
• GRAVEL/ROCK WITHIN SAMPLE COMPROMISES INTEGRITY OF THE SAMPLE TO PROVIDE AN ACCURATE MEASUREMENT
• LOW POTENTIAL TO DETERMINE “MACROPORES” IN THE BARRIER LAYER
• POTENTIAL DISTURBANCE IN DELIVERY TO THE LAB
LIMITATIONS OF
LABORATORY HYDRAULIC CONDUCTIVITY TESTS
![Page 4: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/4.jpg)
• SEALED DOUBLE RING INFILTROMETER TEST (SDRI)
• TWO STAGE BOUTWELL PERMEAMETER (TSB)
INDUSTRY ACCEPTED FIELD TEST METHODS FOR DETERMINATION OF
HYDRAULIC CONDUCTIVITY OF LANDFILL BARRIERS
![Page 5: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/5.jpg)
TDSWM CQA GUIDANCE POLICY
TABLE 2
![Page 6: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/6.jpg)
TWO STAGE BOUTWELL PERMEAMETER (TSB) / ASTM D6391 Standard Test Method for Field Measurement of Hydraulic Conductivity Using Borehole Infiltration
![Page 7: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/7.jpg)
Typical Cross Section of the Two Stage Boutwell Permeameter (TSB)
![Page 8: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/8.jpg)
COMPACT CONSTANT HEAD PERMEAMETER (AKA AMOOZEMETER) DEVELOPED BY: AZIZ AMOOZGAR NORTH CAROLINA STATE UNIVERSITY
![Page 9: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/9.jpg)
AMOOZEMETER SCHEMATIC
![Page 10: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/10.jpg)
Amoozemeter Typical Cross Section
![Page 11: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/11.jpg)
Clay Liner Amoozemeter Test Setup
![Page 12: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/12.jpg)
Clay Liner Amoozemeter Test Setup
![Page 13: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/13.jpg)
Amoozemeter Test in Progress
![Page 14: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/14.jpg)
Amoozemeter Test in Progress
![Page 15: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/15.jpg)
Amoozemeter Data Sheet
![Page 16: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/16.jpg)
Comparison of Amoozemeter Tests with
ASTM D5084 Lab Test
Measurement
Number
Test/Sample
Location Lift/Layer
Amoozemeter Ksat
AVG [cm/s]
Ksat (ASTM D5084)
(cm/sec)
1 Test Pad West 1 2.13E-06 1.10E-06
2 NE Corner of test
Pad 2 and 3
8.00E-06
2.00E-06
3 NE Corner of test
Pad 2 and 3 9.00E-07
![Page 17: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/17.jpg)
• The Amoozemeter can be used to measure silty/sandy soils situated within the geologic buffer zone in certain areas of Tennessee where the anticipated hydraulic conductivity exceeds 1 x 10-6 cm/sec
• Hydraulic head is not significant enough to measure below 1 x 10-6 cm/sec
• The constant head provided by the Amoozemeter was the intriguing aspect of the test that triggered this experiment
Conclusions
![Page 19: Amoozemeter Field Demonstration for Determining Landfill](https://reader030.vdocuments.mx/reader030/viewer/2022012602/61989d5a9021073c1378bc18/html5/thumbnails/19.jpg)
CONNECT WITH US!
www.cecinc.com
Questions?