ames, iowa - master development plan · ames, iowa - master development plan (745.45 acres) map...
TRANSCRIPT
![Page 1: AMES, IOWA - MASTER DEVELOPMENT PLAN · AMES, IOWA - MASTER DEVELOPMENT PLAN (745.45 ACRES) Map Prepared: November 2019 0 0.125 0.25 0.5 Miles Proposed Pad 1,200,000 SF Li nc ol Wa](https://reader030.vdocuments.mx/reader030/viewer/2022040608/5ec662169d9ec177a95cde8c/html5/thumbnails/1.jpg)
&M
&M
&M
&M
!\
!\
AMES, IOWA - MASTER DEVELOPMENT PLAN(745.45 ACRES)
Map Prepared: November 2019
0 0.25 0.50.125Miles
Proposed Pad1,200,000 SF
Lincoln Way
Union Pacific
Legend*
All dashed lines indicate proposed Utility routes*
Total Developable: 662.82 AcresProposed Road
Proposed RailExisting Railroad
PRAIRIE VIEW INDUSTRIAL CENTER
Wetland Delineation(Foth Infrastructure &Environment, LLC, May 2018)
Jurisdictional Wetland (J)Non-Jurisdictional Wetland (NJ)Stream Channel
Water Main (City of Ames)Sanitary Main (City of Ames)Natural Gas Distribution Line (Alliant Energy)
12.47 kV Electric Distribution Line (Alliant Energyor Consumers Energy, as indicated)
69 kV Electric Transmission Line (ITC Midwest)
Telecommunications (Central Iowa Broadband)
VERBIONorth
America
BarillaAmerica§̈¦35
Lincoln Way
Lincoln Hwy
590th
Ave.
Potte
r Ave
.
Telle
r Ave
.
580th
Ave.
£¤30
Flemi
ng Av
e.
IowaDOT
580th
Ave.
Union Pacific
§̈¦35
566th
Ave.
Non-Developable Land
Lot 581.1 Acres78.6 Acres
Developable
Lot 480.1 Acres70.8 Acres
Developable
Lot 1101.9 Acres90.7 Acres
Developable
Lot2106.3 Acres104.9 AcresDevelopable
Lot 3102.8 Acres92.7 Acres
Developable
Lot 6155.7 Acres148 Acres
Developable
Lot 7117.6 Acres77.3 Acres
Developable
0.2 AcreWetland (NJ)
0.4 AcreWetland (NJ)
0.2 AcreWetland (J)
0.3 AcreWetland (NJ) 0.1 Acre
Wetland (NJ)
0.2 AcreWetland (J)
0.1 AcreWetland (J)
100-YearFloodplain
Septic System0.1 Acres
Dwelling, Well/Septicand Machine Shed
3.6 Acres Dwelling, Well/Septicand Machine Shed
2.9 Acres
100-YearFloodplain
0.1 AcreWetland (J)
Well0.1 Acres
0.1 AcreWetland (J)
0.1 AcreWetland (J)
100-YearFloodplain
0.1 AcreWetland (J)
0.3 AcreWetland (J)
10 Gb Fiber Line
10" Natural Gas Line(120 psi)
Parallel 4" and 10"Natural Gas Lines(55 and 120 psi)
Parallel 8" and 10"Natural Gas Lines
(120 psi)
Natural GasRegulator
Station
Proposed Lift Station
Natural GasRegulator
Station
ProposedWater
StorageTank
12" Water Main
Proposed 12-15"Sewer Main
(Gravity)
Proposed 12"Water Main
Proposed 12"Sewer Force Main
(to connect with existingmain at Bell Avenue - 800 feet west of I-35)
Allian
t Ene
rgyele
ctric
servi
ce te
rritory
Cons
umers
Energ
yele
ctric
servi
ce te
rritory
36" Sewer Main
12.47 kV Alliant EnergyElectric Distribution Line
ElectricSubstation
Parallel 4" and 12"Natural Gas Lines(55 and 120 psi)
4" NaturalGas Line(55 psi)
0.1 AcreWetland (J)
12.47 kV Alliant Energy Electric Distribution Line,
concurrent with 69 kVITC Transmission Line
12.47 kV Consumers EnergyElectric Distribution Line
12.47 kV Consumers EnergyElectric Distribution Line