SS-AMEC96 www.amana-hac.com 9/14 Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. AMEC96 HEATING INPUT: 30,000–120,000 BTU/H Contents Nomenclature ........................................... 2 Product Specifications .............................. 3 Dimensions ............................................... 4 Airflow Specifications................................ 6 Wiring Diagram......................................... 9 Accessories .............................................. 10 Thermostats ............................................ 10 TWO-STAGE, MULTI-SPEED ECM GAS FURNACE UP TO 96% AFUE Standard Features Energy-efficient multi-speed ECM blower motor Heavy-duty stainless-steel tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage gas valve provides quiet, economical heating Durable Silicon Nitride igniter Quiet two-speed induced draft blower Self-diagnostic control board with constant memory fault code history output to a LED Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Low continuous fan speed options offer quiet air circulation All models comply with California Low NOx emissions standards Cabinet Features Designed for multi-position installation — upflow, horizontal left or right Certified for direct vent (2-pipe) or non-direct vent (1-pipe) Easy-to-install top venting with optional side venting Convenient left or right connection for gas and electrical service Cabinet air leakage (Q Leak ) ≤ 2% Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower section Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger Limited Warranty, (good for as long as you own your home) Lifetime Unit Replacement Limited Warranty (good for as long as you own your home) and the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

Upload: duonghanh

Post on 16-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

SS-AMEC96 www.amana-hac.com 9/14Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.

AMEC96

HEAting input: 30,000–120,000 Btu/H

ContentsNomenclature ...........................................2Product Specifications ..............................3Dimensions ...............................................4Airflow Specifications ................................6Wiring Diagram .........................................9Accessories ..............................................10 Thermostats ............................................10

two-StAgE, Multi-SpEEd ECM gAS FurnACE

up to 96% AFuE

Standard Features• Energy-efficient multi-speed ECM blower motor• Heavy-duty stainless-steel tubular heat exchanger • Stainless-steel secondary heat exchanger• Two-stage gas valve provides quiet,

economical heating • Durable Silicon Nitride igniter• Quiet two-speed induced draft blower• Self-diagnostic control board with constant memory

fault code history output to a LED• Color-coded low-voltage terminals with provisions for

electronic air cleaner and humidifier• Low continuous fan speed options offer

quiet air circulation• All models comply with California Low NOx

emissions standards

Cabinet Features• Designed for multi-position installation —

upflow, horizontal left or right• Certified for direct vent (2-pipe) or

non-direct vent (1-pipe) • Easy-to-install top venting with optional

side venting• Convenient left or right connection

for gas and electrical service• Cabinet air leakage (QLeak) ≤ 2% • Heavy-gauge steel cabinet with durable finish• Fully insulated heat exchanger and blower section• Airtight solid bottom or side return with easy-cut tabs

for effortless removal in bottom air-inlet applications

* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger Limited Warranty, (good for as long as you own your home) Lifetime Unit Replacement Limited Warranty (good for as long as you own your home) and the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

Product SPecificationS

2 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 3

noMEnClAturE

A M E C 96 060 3 B N A A1 2 3 4 5,6 7,8,9 10 11 12 13 14

Brand Minor  RevisionA-­‐  Amana      A  -­‐  Initial  Release

     B  -­‐  1st  RevisionConfigurationM  -­‐  Upflow/Horizontal Major  RevisionC  -­‐  Downflow/Horizontal      A  -­‐  Initial  Release

     B  -­‐  1st  RevisionMotorV  -­‐  Variable  Speed  ECM  /  ComfortNet NOxE  -­‐  Multi-­‐Speed  ECM        N  -­‐  Low  NOxS  -­‐  Single  Speed

Cabinet  WidthGas  Valve      B  -­‐  17.5"M  -­‐  Modulating      C  -­‐  21"C  -­‐  2  Stage        D  -­‐  24.5"S  -­‐  Single  Stage

Maximum  CFMAFUE      2  -­‐      800  CFM92  -­‐    92%  AFUE      3  -­‐  1200  CFM96  -­‐    96%  AFUE      4  -­‐  1600  CFM97  -­‐  97%  AFUE      5  -­‐  2000  CFM

MBTU/h040  -­‐  40,000  BTU/h060  -­‐  60,000  BTU/h120  -­‐  120,000  BTU/h

Amana  +90%  Furnace  Nomenclature

Product SPecificationS

2 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 3

SpECiFiCAtionS

¹ Natural Gas BTU/h² DOEAFUEbaseduponIsolatedCombustionSystem(ICS)³ InstallermustsupplyoneortwoPVCpipes:oneforcombustionair(optional)andonefortheflueoutlet(required).

Ventpipemustbeeither2"or3"indiameter,dependinguponfurnaceinput,numberofelbows,lengthofrun andinstallation(1or2pipes).TheoptionalCombustionAirPipeisdependentoninstallation/coderequirements andmustbe2"or3"diameterPVC.

⁴ MinimumCircuitAmpacity=(1.25xCirculatorBlowerAmps)+IDBloweramps.Wiresizeshouldbedetermined inaccordancewithNationalElectricalCodes.Extensivewirerunswillrequirelargerwiresizes.

⁵ MaximumOvercurrentProtectionDevicereferstomaximumrecommendedfuseorcircuitbreakersize. MayusefusesorHACR-typecircuitbreakersofthesamesizeasnoted.

Notes• Allfurnacesaremanufacturedforuseon115VAC,60Hz,single-phaseelectricalsupply.• GasServiceConnection½"FPT• Important:Sizefusesandwiresproperlyandmakeelectricalconnectionsinaccordancewiththe

NationalElectricalCodeand/orallexistinglocalcodes.• Forbottomreturn:Failuretounfoldflangesmayreduceairflowbyupto18%.Thiscouldresultinperformance

andnoiseissues.• Forservicingorcleaning,a24"frontclearanceisrequired.Unitconnections(electrical,flueanddrain)

maynecessitategreaterclearancesthantheminimumclearanceslistedabove.Inallcases,accessibility clearancemusttakeprecedenceoverclearancesfromtheenclosurewhereaccessibilityclearancesaregreater.

AMEC96 0302BNA

AMEC960402BNA

AMEC960603BNA

AMEC960803CNA

AMEC961004CNA

AMEC961205DNA

Heating DataHighFireInput¹ 30,000 40,000 60,000 80,000 100,000 120,000

HighFireOutput¹ 28,800 38,400 57,600 76,800 96,000 115,200Low-FireSteady-StateInput¹ 21,000 28,000 42,000 56,000 70,000 84,000Low-FireSteady-StateOutput¹ 20,160 26,880 40,320 53,760 67,200 80,640

AFUE² 96 96 96 96 96 96

TemperatureRiseRange(°F) - 20-50 20-50 35-65 35-65 35-65

VentDiameter³ 2"-3" 2"-3" 2"-3" 2"-3" 2"-3" 2"-3"No.ofBurners 2 2 3 4 5 6

Circulator [email protected]"ESP 1.5-2 1.5-3 1.5-3 1.5-3 1.5-4 3-5

Size(DxW) 10"x8" 10"x8" 11"x8" 11"x8" 11"x10" 11"x11"

Horsepower@1075RPM ½ ½ ½ ½ 1 1Speed 5 5 5 5 5 5

Filter Size (in²)Permanent 366 341 512 683 1,067 1,024Disposable 183 171 256 341 533 512

Electrical DataMin.CircuitAmpacity⁴ 8 8 8 8 13.3 13.3

Max.OvercurrentDevice(amps)⁵ 15 15 15 15 15 15

Shipping Weight (lbs) 111 112 115 118 140 154

Product SPecificationS

4 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 5

AMEC96 diMEnSionS

MiniMuM ClEArAnCES to CoMBuStiBlE MAtEriAlS

Position Sides Rear Front Bottom Flue TopUpflow 0" 0" 3" C 0" 1"

Horizontal 6" 0" 3" C 0" 6"

C=Ifplacedoncombustiblefloor,thefloorMUSTbewoodONLY.

Model A B C D EAMEC960302BNA 17½" 16" 13⅞" 12⅛" 13⅝"AMEC960402BNA 17½" 16" 13⅞" 12⅛" 13⅝"AMEC960603BNA 17½" 16" 13⅞" 12⅛" 13⅝"AMEC960803BNA 17½" 16" 13⅞" 12⅛" 13⅝"AMEC961004CNA 21" 19½" 17⅜" 16" 17½"AMEC961205DNA 24½ 23" 20⅞" 19⅜" 20⅞"

59¼

19⅝

34½

¾

19½

¾

DIM BDISCHARGE

23

2⅜

1⅞

2

C

5

19⅝23

24⅞

31⅞

A

21⅛

2⅝

14

23

1⅜

¾

28¾

2⅜1⅞

2

2¾6½

1⅞

26½

23½UNFOLDED FLANGES

22FOLDED FLANGES

DFOLDED FLANGES

EUNFOLDED FLANGES

AIRDISCHARGE

SIDE CUT-OUT SIDE CUT-OUT

AIRDISCHARGE

LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW

CONDENSATE DRAINTRAP EXTERIOR

CONNECTION(RIGHT OR LEFT SIDE)

¾ PVC

VENT/FLUE PIPE2" PVC ALTERNATE

VENT/FLUELOCATION

RIGHT SIDEDRAIN TRAP

EXTERIOR HOLESHIGH VOLTAGE

ELECTRICAL OUTLET

ALTERNATEGAS SUPPLY

LOW VOLTAGEELECTRICAL OUTLET

STANDARD GAS SUPPLYLOCATION

CENTER DIMPLEFOR ALTERNATEAIR INTAKE PIPE3" OD HOLE

AIR INTAKE2" PIPE

LEFT SIDEDRAIN TRAP

EXTERIOR HOLESHIGH VOLTAGEELECTRICAL OUTLET

LOW VOLTAGEELECTRICAL OUTLET

Product SPecificationS

4 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 5

AMEC96 AirFlow dAtA

Notes• Allfurnacesshipashighspeedforcooling.Installermustadjustblowerspeedasneeded.• Formostjobs,about400CFMpertonwhencoolingisdesirable.• Donotoperateabove.5"w.c.ESPinheatingmode.OperatingCFMbetween.5"and.8"w.c.istabulatedforcoolingpurposesonly.

AMEC960402BNADIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 847 694 611 535 471 415 357 313All DIP Switch Positions W1 T1 847 29 694 36 611 41 535 47 471 53 415 357 313All DIP Switch Positions W2 T2 989 36 932 38 882 40 819 43 773 46 695 650 586

OFF OFF OFFYlo T3 856 667 546 466 413 357 302 N/AY T5 1143 1095 1046 996 946 890 834 778

ON OFF OFFYlo T3 856 667 546 466 413 357 302 N/AY T4 960 898 840 780 711 659 596 547

ON ON OFFYlo T4 960 898 840 780 711 659 596 547Y T5 1143 1095 1046 996 946 890 834 778

OFF ON OFFYlo T4 960 898 840 780 711 659 596 547Y T1 847 694 611 535 471 415 357 313

OFF OFF ONYlo T4 960 898 840 780 711 659 596 547Y T2 989 932 882 819 773 695 650 586

OFF ON ONYlo T3 856 667 546 466 413 357 302 N/AY T5 1143 1095 1046 996 946 890 834 778

ON OFF ONYlo T2 989 932 882 819 773 695 650 586Y T5 1143 1095 1046 996 946 890 834 778

ON ON ON Ylo T2 989 932 882 819 773 695 650 586Y T3 856 667 546 466 413 357 302 N/A

FACT

ORY

SE

TTIN

G

AMEC960302BNADIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 870 658 548 469 413 349 293 N/AAll DIP Switch Positions W1 T1 870 21 658 28 548 34 469 40 413 45 349 293 N/AAll DIP Switch Positions W2 T2 885 30 821 32 755 35 684 39 621 43 557 508 461

OFF OFF OFFYlo T3 874 697 612 533 470 414 361 303Y T5 1146 1097 1049 1002 941 895 846 787

ON OFF OFFYlo T3 874 697 612 533 470 414 361 303Y T4 928 868 810 743 670 614 560 505

ON ON OFFYlo T4 928 868 810 743 670 614 560 505Y T5 1146 1097 1049 1002 941 895 846 787

OFF ON OFFYlo T4 928 868 810 743 670 614 560 505Y T1 870 658 548 469 413 349 293 N/A

OFF OFF ONYlo T4 928 868 810 743 670 614 560 505Y T2 885 821 755 684 621 557 508 461

OFF ON ONYlo T3 874 697 612 533 470 414 361 303Y T5 1146 1097 1049 1002 941 895 846 787

ON OFF ONYlo T2 885 821 755 684 621 557 508 461Y T5 1146 1097 1049 1002 941 895 846 787

ON ON ON Ylo T2 885 821 755 684 621 557 508 461Y T3 874 697 612 533 470 414 361 303

FACT

ORY

SE

TTIN

G

Product SPecificationS

6 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 7

AMEC96 AirFlow dAtA (Cont.)

Notes• Allfurnacesshipashighspeedforcooling.Installermustadjustblowerspeedasneeded.• Formostjobs,about400CFMpertonwhencoolingisdesirable.• Donotoperateabove.5"w.c.ESPinheatingmode.OperatingCFMbetween.5"and.8"w.c.istabulatedforcoolingpurposesonly.

AMEC960803BNADIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 1221 1172 1128 1087 1049 1005 959 922All DIP Switch Positions W1 T1 1221 41 1172 42 1128 44 1087 46 1049 47 1005 959 922All DIP Switch Positions W2 T2 1311 54 1293 55 1249 57 1203 59 1172 61 1122 1088 1041

OFF OFF OFFYlo T3 750 644 569 507 442 388 328 N/AY T5 1111 1068 1025 984 941 885 N/A 801

ON OFF OFFYlo T3 750 644 569 507 442 388 328 N/AY T4 894 842 784 726 682 618 562 519

ON ON OFFYlo T4 894 842 784 726 682 618 562 519Y T5 1111 1068 1025 984 941 885 N/A 801

OFF ON OFFYlo T4 894 842 784 726 682 618 562 519Y T1 1221 1172 1128 1087 1049 1005 959 922

OFF OFF ONYlo T4 894 842 784 726 682 618 562 519Y T2 1311 1293 1249 1203 1172 1122 1088 1041

OFF ON ONYlo T3 750 644 569 507 442 388 328 N/AY T5 1111 1068 1025 984 941 885 N/A 801

ON OFF ONYlo T2 1311 1293 1249 1203 1172 1122 1088 1041Y T5 1111 1068 1025 984 941 885 N/A 801

ON ON ON Ylo T2 1311 1293 1249 1203 1172 1122 1088 1041Y T3 750 644 569 507 442 388 328 N/A

FACT

ORY

SE

TTIN

G

AMEC960603BNADIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 894 846 780 720 660 603 554 505All DIP Switch Positions W1 T1 894 42 846 44 780 48 720 52 660 57 603 554 505All DIP Switch Positions W2 T2 1328 40 1287 41 1249 43 1215 44 1170 46 1131 1085 1046

OFF OFF OFFYlo T3 782 629 547 469 396 333 N/A N/AY T5 1236 1189 1149 1101 1066 1017 969 928

ON OFF OFFYlo T3 782 629 547 469 396 333 N/A N/AY T4 1149 1104 1057 1017 963 918 865 822

ON ON OFFYlo T4 1149 1104 1057 1017 963 918 865 822Y T5 1236 1189 1149 1101 1066 1017 969 928

OFF ON OFFYlo T4 1149 1104 1057 1017 963 918 865 822Y T1 894 846 780 720 660 603 554 505

OFF OFF ONYlo T4 1149 1104 1057 1017 963 918 865 822Y T2 1328 1287 1249 1215 1170 1131 1085 1046

OFF ON ONYlo T3 782 629 547 469 396 333 N/A N/AY T5 1236 1189 1149 1101 1066 1017 969 928

ON OFF ONYlo T2 1328 1287 1249 1215 1170 1131 1085 1046Y T5 1236 1189 1149 1101 1066 1017 969 928

ON ON ON Ylo T2 1328 1287 1249 1215 1170 1131 1085 1046Y T3 782 629 547 469 396 333 N/A N/A

FACT

ORY

SE

TTIN

G

Product SPecificationS

6 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 7

AMEC96 AirFlow dAtA (Cont.)

Notes• Allfurnacesshipashighspeedforcooling.Installermustadjustblowerspeedasneeded.• Formostjobs,about400CFMpertonwhencoolingisdesirable.• Donotoperateabove.5"w.c.ESPinheatingmode.OperatingCFMbetween.5"and.8"w.c.istabulatedforcoolingpurposesonly.

AMEC961205DNDIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 1796 1753 1697 1645 1589 1536 1478 1425All DIP Switch Positions W1 T1 1796 42 1753 43 1697 44 1645 45 1589 47 1536 1478 1425All DIP Switch Positions W2 T2 2211 48 2162 49 2122 50 2076 51 2029 53 1986 1984 1942

OFF OFF OFFYlo T3 1106 1017 946 855 764 681 605 N/AY T5 1683 1628 1565 1511 1445 1387 1340 1276

ON OFF OFFYlo T3 1106 1017 946 855 764 681 605 N/AY T4 1399 1327 1259 1185 1118 1051 980 913

ON ON OFFYlo T4 1399 1327 1259 1185 1118 1051 980 913Y T5 1683 1628 1565 1511 1445 1387 1340 1276

OFF ON OFFYlo T4 1399 1327 1259 1185 1118 1051 980 913Y T1 1796 1753 1697 1645 1589 1536 1478 1425

OFF OFF ONYlo T4 1399 1327 1259 1185 1118 1051 980 913Y T2 2211 2162 2122 2076 2029 1986 1984 1942

OFF ON ONYlo T3 1106 1017 946 855 764 681 605 N/AY T5 1683 1628 1565 1511 1445 1387 1340 1276

ON OFF ONYlo T2 2211 2162 2122 2076 2029 1986 1984 1942Y T5 1683 1628 1565 1511 1445 1387 1340 1276

ON ON ON Ylo T2 2211 2162 2122 2076 2029 1986 1984 1942Y T3 1106 1017 946 855 764 681 605 N/A

FACT

ORY

SE

TTIN

G

AMEC960803BNADIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 1221 1172 1128 1087 1049 1005 959 922All DIP Switch Positions W1 T1 1221 41 1172 42 1128 44 1087 46 1049 47 1005 959 922All DIP Switch Positions W2 T2 1311 54 1293 55 1249 57 1203 59 1172 61 1122 1088 1041

OFF OFF OFFYlo T3 750 644 569 507 442 388 328 N/AY T5 1111 1068 1025 984 941 885 N/A 801

ON OFF OFFYlo T3 750 644 569 507 442 388 328 N/AY T4 894 842 784 726 682 618 562 519

ON ON OFFYlo T4 894 842 784 726 682 618 562 519Y T5 1111 1068 1025 984 941 885 N/A 801

OFF ON OFFYlo T4 894 842 784 726 682 618 562 519Y T1 1221 1172 1128 1087 1049 1005 959 922

OFF OFF ONYlo T4 894 842 784 726 682 618 562 519Y T2 1311 1293 1249 1203 1172 1122 1088 1041

OFF ON ONYlo T3 750 644 569 507 442 388 328 N/AY T5 1111 1068 1025 984 941 885 N/A 801

ON OFF ONYlo T2 1311 1293 1249 1203 1172 1122 1088 1041Y T5 1111 1068 1025 984 941 885 N/A 801

ON ON ON Ylo T2 1311 1293 1249 1203 1172 1122 1088 1041Y T3 750 644 569 507 442 388 328 N/A

AMEC961004CNDIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 1522 1464 1402 1338 1280 1230 1167 1101All DIP Switch Positions W1 T1 1522 41 1464 43 1402 44 1338 47 1280 49 1230 1167 1101All DIP Switch Positions W2 T2 1861 48 1803 49 1749 51 1698 52 1653 54 1594 1549 1504

OFF OFF OFFYlo T3 1004 890 805 710 620 553 474 406Y T5 1772 1713 1662 1609 1540 1498 1452 1399

ON OFF OFFYlo T3 1004 890 805 710 620 553 474 406Y T4 1312 1235 1170 1101 1037 962 880 820

ON ON OFFYlo T4 1312 1235 1170 1101 1037 962 880 820Y T5 1772 1713 1662 1609 1540 1498 1452 1399

OFF ON OFFYlo T4 1312 1235 1170 1101 1037 962 880 820Y T1 1522 1464 1402 1338 1280 1230 1167 1101

OFF OFF ONYlo T4 1312 1235 1170 1101 1037 962 880 820Y T2 1861 1803 1749 1698 1653 1594 1549 1504

OFF ON ONYlo T3 1004 890 805 710 620 553 474 406Y T5 1772 1713 1662 1609 1540 1498 1452 1399

ON OFF ONYlo T2 1861 1803 1749 1698 1653 1594 1549 1504Y T5 1772 1713 1662 1609 1540 1498 1452 1399

ON ON ON Ylo T2 1861 1803 1749 1698 1653 1594 1549 1504Y T3 1004 890 805 710 620 553 474 406

FACT

ORY

SE

TTIN

G

AMEC960603BNADIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFMAll DIP Switch Positions G T1 894 846 780 720 660 603 554 505All DIP Switch Positions W1 T1 894 42 846 44 780 48 720 52 660 57 603 554 505All DIP Switch Positions W2 T2 1328 40 1287 41 1249 43 1215 44 1170 46 1131 1085 1046

OFF OFF OFFYlo T3 782 629 547 469 396 333 N/A N/AY T5 1236 1189 1149 1101 1066 1017 969 928

ON OFF OFFYlo T3 782 629 547 469 396 333 N/A N/AY T4 1149 1104 1057 1017 963 918 865 822

ON ON OFFYlo T4 1149 1104 1057 1017 963 918 865 822Y T5 1236 1189 1149 1101 1066 1017 969 928

OFF ON OFFYlo T4 1149 1104 1057 1017 963 918 865 822Y T1 894 846 780 720 660 603 554 505

OFF OFF ONYlo T4 1149 1104 1057 1017 963 918 865 822Y T2 1328 1287 1249 1215 1170 1131 1085 1046

OFF ON ONYlo T3 782 629 547 469 396 333 N/A N/AY T5 1236 1189 1149 1101 1066 1017 969 928

ON OFF ONYlo T2 1328 1287 1249 1215 1170 1131 1085 1046Y T5 1236 1189 1149 1101 1066 1017 969 928

ON ON ON Ylo T2 1328 1287 1249 1215 1170 1131 1085 1046Y T3 782 629 547 469 396 333 N/A N/A

Product SPecificationS

8 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 9

tEMpErAturE riSE rAngE CHArt

3040

5060

7080

9011

012

010

013

014

015

0

100

90 80 70 60 50 40 30 20 10

OU

TPU

TB

TU/H

Rx

1000

BTU

OU

TPU

Tvs

TEM

PE

RAT

UR

ER

ISE

CH

AR

T

TEMPERATURERISE

600

CFM

700

900 10

00 1100 12

00

1400

1600 18

00 2000 22

00 2400

CFM

FOR

MU

LAS

BTU

OU

TPU

T=

CFM

x1.

08x

RIS

E

RIS

E=

BTU

OU

TPU

T1.

08÷

CFM

800

TemperatureRise

Out

put

BTU

/h x

1,0

00

Form

ulas

BTU/hOutpu

t=CFM

x1.08xRise

Rise=

BTU/H

Outpu

t

CFMx1.08

BTU

Out

put

Vs. T

empe

ratu

re R

ise

Char

t

Product SPecificationS

8 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 9

wiring diAgrAM

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost u

p-to

-dat

e w

iring

.⚠

Wa

rnin

gHi

gh V

olta

ge:

Dis

conn

ect

all

pow

er b

efor

e se

rvic

ing

or i

nsta

lling

thi

s un

it. M

ultip

le p

ower

so

urce

s m

ay b

e pr

esen

t. Fa

ilure

to d

o so

may

cau

se p

rope

rty

dam

age,

per

sona

l inj

ury,

or

deat

h.⚡

GN

GND

COLOR CODES:

GN GREEN

RD REDGY G RAY

PU PURPLE

PK PINK

BK BLACK

BL BLUEWH WHITEBR BROWN

YL YELLOWOR ORANGE

GND

BK

RD

RD

GN

GN

24VA

C

115VA

C

GND

GR

D

BK

YLO Y W1 W2 R G C TWIN

0140F02011-A

BRPK

GY

OR

GN

BL

YL

S2

S1

BK

HU

MX-FM

RL1C

IRC

-HE

AC

-H

5

21

43

24 V 3 AFUSE

NEUTRAL

DIAGNOSTIC

LED S'

5 CIR

CU

IT CO

NN

ECTO

R

10

63

4

52

7

11

1

12

8

9

FRONT COVERPRESSURE SWITCH

NO

C

FUSE 3 A

MICROTO

PS2 (2)

TR (9)

G

HI

C

TH (5)

24V TH

ER

MO

STA

T CO

NN

EC

TION

S

VALVEGAS

W2

TRANSFORMER

HLI (6)

Y2

Y1 HLO (11)

GND (4)

O

MVL (7)

NO

W1

C

R

CONTROLSAUTO RESET AUXILIARY LIMIT

LIMIT CONTROLSMANUAL RESET ROLLOUTPRESS. SWTICH

HIGH FIRE

C

SWITCHLOW FIRE PRESS.

MVH ( 1)

DEHUM

GND

PS1 (12)

LIMIT CONTROLAUTO RESET PRIMARY24 VAC

NO

PM

MVC ( 8)

INTEGRATED CONTROL MODULE

C

BLWR

AIRINDOOR

C RI CULATOR

RTO

MICROTO

TO+VDC

EAC

HUMIDIFIER

ID

NEUTRAL

WIRING TO UNIT

L

INTE

GR

ATE

D C

ON

TRO

L MO

DU

LE

HOT SURFACE

GND

BLWR

NEUTRAL

WARNING:

GROUNDED.

OVERCURRENT PROTECTION DEVICE

MUST BE PROPERLY

SWITCH

NEUTRAL

ELECTRONIC

AIR

IGN

IND HI

D SI CONNECT

FS

POLARIZED AND

NEUTRAL

LINE

NEUTRAL

JUNCTION BOX

BLWR

IND LO

N

INDOOR

AIR CLEANER

HUM

DOOR

NEUTRAL

INTE

GR

ATE

D C

ON

TRO

L MO

DU

LE

TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH

115 VAC

HUM-OUT

IGN TI ER

C RI CULATOR

BEFORE SERVICING.

FLAME SENSOR

DISCONNECT POWER

LINE

GND

T4

T1T2

OR

BR

BK W

HW

HW

HW

H

PU

GY

YL

OR

BR

PK

RD

WH B

K

PU

GY

BR

OR

RDBK

ORBL

RD

WH

WH

T3

CO

M

LINE

NO

LIMIT CONTROLAUXILIARYAUTO RESET

PK

WARNING:DISCONNECT

TRA

NS

FOR

ME

R40 V

A

PU

GY

NNO

3

BR

1

SWITCHPRESSURELOW FIRE

SENSORFLAME

PRESSURE SWITCHFRONT COVER

C TO UNIT MUST BE

BL

RD

AND GROUNDED.

1

JUN

CTIO

N BO

X

WH

SWITCH (PRESS.)

FIELD SPLICEFIELD GND

3

GN

BL

BRWH

NO

LIMIT CONTROLAUTO RESET PRIMARY

WH

1

OR

30 kBTU AND 40 kBTU)CONTROLS (SINGLE CONTROL ON

MANUAL RESET ROLLOUT LIMIT

WH

L

PU

GY

BK

SWITCH ASSEMBLYID BLOWER TWO-STAGE PRESSURE

OR

WH

SERVICING. WIRING

EQUIPMENT GND

INTERNAL TO

SWITCHPRESSUREHIGH FIRE

PROT. DEVICE

INTEGRATED CONTROL

PK

PU

PLUG CONNECTION

2

4

BK

C

DOOR OPEN)(OPEN WHENDOOR SWITCHCOMPARTMENTBLOWER

SWITCH (TEMP.)

GND

1

BLOWERCIRCULATOR

JUNCTION

OR

40 VA

Ø /60 HZ

DISCONNECT

(WHITE RODGERS)GAS VALVETWO STAGE

OVERCURRENT

CONNECTOR2 CIRCUIT

LOW VOLTAGE (24V)

YL

GND

WH

CH

ASS

IS G

RO

UN

D2

3

IGNITERSURFACE

HOT

2

YL

PU

C

2

C

BLOWERDRAFT

INDUCED

BK

PM

BK

BLOWER COMPARTMENT

115 VAC/ 1

OVERCURRENT

BK

HARNESSECM MTR

HI

TERMINAL

OR

POWER BEFORE

IGNITER

RD

BK

TO

RD

POWER SUPPLY WITH

BURNER COMPARTMENT

PROTECTION DEVICE

PROPERLY POLARIZED

RDBK

ORBL

LOW VOLTAGE FIELDHI VOLTAGE (115V)HI VOLTAGE FIELD

RAPID = TWINNING ERROR

STEADY ON = INTERNAL GV ERROR, M ICRO AND FREQUENCY CHECK

1 FLASH = FLAME SENSED WHEN NO FLAME SHOULD BE P RESENT

4 FLASHES = OPEN LIMIT SWITCH

0

4

3

2

1

RED LED FLASH CODE

2 FLASHES = PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR

3 FLASHES = 1ST STAGE PRESSURE SWITCH STUCKCLOSED/INDUCER ERROR

5 FLASHES = OPEN ROLLOUT/OPEN FUSE DETECTED

6 FLASHES = PRESSURE SWITCH CYCLE LOCKOUT

7 FLASHES = EXTERNAL LOCKOUT (RETRIES)

9

6

5

7

8 8 F LASHES = EXTERNAL LOCKOUT (RECYCLES)

9 FLASHES + GROUNDING OR REVERSED POLARITY

10 FLASHES = GAS FLOW WITH NO CALL F OR HEAT

11 FLASHES = LIMIT SWITCH O PEN-BLOWER FAILURE

12 FLASHES = IGNITOR RELAY FAILURE

11

10

12

3 DOUBLE F LASHES = 2ND STAGE PRESSURE SWITCHSTUCK OPEN/INDUCER ERROR

3 FLASHES = W2 PRESENT WITH NO W1

2 FLASHES = N ORMAL OPERATION WITHCALL FOR 2ND STAGE H EAT

1 FLASH = N ORMAL OPERATION WITH C ALL FOR1ST STAGE HEAT (W1)

2

4

3

1

4 FLASHES = Y PRESENT WITH NO G CALL, YLOPRESENT WITH N O G CALL

AMBER EL D FLASH CODE

RAPID = LOW FLAME SENSE CURRENT

RAPID = NORMAL OPERATION W ITH CALL FOR FAN (G)

STEADY ON = S TANDBY

1 FLASH = NORMAL OPERATION W ITH CALL FORLOW STAGE COOL (YLO + G)

0

2

1

GREEN LED FLASH CODE

2 FLASHES = NORMAL OPERATION WITH CALL FOR HIGHSTAGE COOL/ OR SINGLE STAGE COOLING (Y + G )

0

1. SET HEAT ANTICIPATOR ON ROOM T HERMOSTAT AT 0.7 AMPS.NOTES:

$

2. MANUFACTURER S' S PECIFIED REPLACEMENT PARTS MUST BE USEDWHEN SERVICING.

MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATER AI LHAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPERCONDUCTORS ONLY.

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E. .C.AND LOCAL CODES.

5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT,DEPRESS SWITCH FOR MORE THAN 2 SECONDS WH LI E IN S TANDBY(NO THERMOSTAT INPUTS)

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE

Product SPecificationS

10 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 11

Model Description AMEC96 0302BNA

AMEC96 0402BNA

AMEC96 0603BNA

AMEC96 0803CNA

AMEC96 1004CNA

AMEC96 1205DNA

CVENT-2 ConcentricVentKit(2") √ √ √ √ √ √CVENT-3 ConcentricVentKit(3") √ √ √ √ √ √RF000142 DrainKit-HorizontalLeftVerticalFlue √ √ √ √ √ √EFR01 ExternalFilterRackwith16"x25"PermanentFilter TBD TBD TBD TBD TBD TBD0170K00000S FlushMountVentKit-3"or2" √ √ √ √ √ √0170K00001S FlushMountVentKit-2" √ √ √ √ √ √AFE18-60A FossilFuel(DuelFuel)Kit √ √ √ √ √ √

High-AltitudeNaturalGasKit TBD TBD TBD TBD TBD TBDHigh-AltitudePressureSwitch TBD TBD TBD TBD TBD TBDHigh-AltitudeLPGasKit TBD TBD TBD TBD TBD TBD

LPLP03 LowLPGasPressureSwitch √ √ √ √ √ √LPM-08 LPConversionKits(GasValve) √ √ √ √ √ √

ACCESSoriES

Product SPecificationS

10 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com 11

notES

Product SPecificationS

12 www.amana-hac.com SS-AMEC96 SS-AMEC96 www.amana-hac.com PB

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2014 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.

notES