Alternators (Part 2) Producer/ Licence N o. Item Description Technical Details Category/ Additional Tests Remarks Cert. No. 1 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract. http://www.cdlive.lr.org/information/ Leroy Somer, Site de Sillac, Bld M arcellin Leroy, Angouleme, France. Electric alternators Type: LSA M 42,2 series: S4, S5, M 6, M 7, L9 LSA M 43,2 series: S1, S15,S25, S35, M 45, L65, L8 LSA M 44,2 series: VS3, VS45, S7, S75, M 95, L12 LSA M 46,2 series: M 3, M 5, L6, L9, VL12 LSA M 47,2 series: VS2, S4, S5, M 7, L9 Expires: 26 M ay 2018 08/ 30007(E2) LSA M 49,1 series: S4, M 5, M 6, M 75, L8, L9 LSA M 50,2 series: S4, M 6, M 7, L8, VL10 LSA M 51,2 series: S55, M 60, L70, VL80, VL85 Above brand labelled for FG Wilson under LL series and for Caterpillar under LC series Power in kVA LS Type / LL Type/ LC Type LSA M 42,2 S4 / NA / NA LSA M 42,2 S5 / LL10#4N / LC10#4N LSA M 42,2 M 6 / NA / NA LSA M 42,2 M 7 / LL10#4Q / LC10#4Q LSA M 42,2 L9 / LL10#4S / LC10#4Q Class F 380V / 50Hz450V / 60Hz690V / 60Hz 15 21 - 18 24 - 21 26 - 23 29 - 25 32 -

Upload: others

Post on 28-May-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    1 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Leroy Somer, Site de Sillac, Bld M arcellin Leroy, Angouleme, France.

    Electric alternators Type: LSAM 42,2 series: S4, S5, M6, M7, L9 LSAM 43,2 series: S1, S15,S25, S35, M45, L65, L8 LSAM 44,2 series: VS3, VS45, S7, S75, M95, L12 LSAM 46,2 series: M3, M5, L6, L9, VL12 LSAM 47,2 series: VS2, S4, S5, M7, L9

    Expires: 26 May 2018

    08/ 30007(E2)

    LSAM 49,1 series: S4, M5, M6, M75, L8, L9 LSAM 50,2 series: S4, M6, M7, L8, VL10 LSAM 51,2 series: S55, M60, L70, VL80, VL85 Above brand labelled for FG Wilson under LL series and for Caterpillar under LC series

    Power in kVA

    LS Type / LL Type/ LC Type LSAM 42,2 S4 / NA / NA LSAM 42,2 S5 / LL10#4N / LC10#4N LSAM 42,2 M6 / NA / NA LSAM 42,2 M7 / LL10#4Q / LC10#4Q LSAM 42,2 L9 / LL10#4S / LC10#4Q

    Class F 380V / 50Hz450V / 60Hz690V / 60Hz 15 21 - 18 24 - 21 26 - 23 29 - 25 32 -

    http://www.cdlive.lr.org/information/

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    2 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    LSAM 42,2 S4 / NA / NA LSAM 42,2 S5 / LL10#4N / LC10#4N LSAM 42,2 M6 / NA / NA LSAM 42,2 M7 / LL10#4Q / LC10#4Q LSAM 42,2 L9 / LL10#4S / LC10#4Q

    Class H 380V / 50Hz450V / 60Hz690V / 60Hz 17.5 22 - 20 26 - 23 30 - 25 32 - 28 35 -

    LSAM 43.2 S1 / LL20#4B / LC20#4B LSAM 43.2 S15 / LL20#4B / LC20#4B LSAM 43.2 S25 / LL20#4B / LC20#4B LSAM 43.2 S35 / LL20#4D / LC20#4D LSAM 43.2 M45 / LL20#4F / LC20#4F LSAM 43.2 L65 / LL20#4H / LC20#4H LSAM 43.2 L8 / LL20#4J / LC20#4j

    Class F 32 40 35 36 45 38 42 50 43 45 52 45 48 57 51 57 66 57 66 76 64

    http://www.cdlive.lr.org/information/

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    3 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Leroy Somer ...continued LSAM 43.2 S1 / LL20#4B / LC20#4B LSAM 43.2 S15 / LL20#4B / LC20#4B LSAM 43.2 S25 / LL20#4B / LC20#4B LSAM 43.2 S35 / LL20#4D / LC20#4D LSAM 43.2 M45 / LL20#4F / LC20#4F LSAM 43.2 L65 / LL20#4H / LC20#4H LSAM 43.2 L8 / LL20#4J / LC20#4j

    Class H 35 44 37 40 50 42 45 55 47 48 58 51 53 63 57 62 73 64 73 85 73

    08/ 30007(E2)

    LSAM 44.2 VS3 / NA / NA LSAM 44.2 VS45 / LL30#4B / LC30#4B LSAM 44.2 S7 / LL30#4D / LC30#4D LSAM 44.2 S75 / NA / NA LSAM 44.2 M95 / LL30#4F / LC30#4F LSAM 44.2 L12 / LL30#4H / LC30#4H

    Class F 80 100 90 90 110 100 105 125 110 110 132 - 127 154 126 135 158 135

    LSAM 44.2 VS3 / NA / NA LSAM 44.2 VS45 / LL30#4B / LC30#4B LSAM 44.2 S7 / LL30#4D / LC30#4D LSAM 44.2 S75 / NA / NA LSAM 44.2 M95 / LL30#4F / LC30#4F LSAM 44.2 L12 / LL30#4H / LC30#4H

    Class H 90 110 100 100 120 110 115 135 123 121 145 - 140 165 145 150 175 150

    http://www.cdlive.lr.org/information/

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    4 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    LSAM 46.2 M3 / LL50#4D / LC50#4D LSAM 46.2 M5 / LL50#4F / LC50#4F LSAM 46.2 L6 / LL50#4H / LC50#4H LSAM 46.2 L9 / LL50#4J / LC50#4J LSAM 46.2 VL12 / LL50#4L / LC50#4L

    Class F 160 188 165 170 200 180 210 250 225 240 290 255 270 320 270

    LSAM 46.2 M3 / LL50#4D / LC50#4D LSAM 46.2 M5 / LL50#4F / LC50#4F LSAM 46.2 L6 / LL50#4H / LC50#4H LSAM 46.2 L9 / LL50#4J / LC50#4J LSAM 46.2 VL12 / LL50#4L / LC50#4L

    Class H 170 205 185 187 220 200 230 280 250 260 320 285 295 355 305

    http://www.cdlive.lr.org/information/

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    5 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Leroy Somer ...continued LSAM 47.2 VS2 / LL61#4B / LC61#4B LSAM 47.2 S4 / LL61#4D / LC61#4D LSAM 47.2 S5 / LL61#4D / LC61#4D LSAM 47.2 M7 / LL61#4F / LC61#4F LSAM 47.2 L9 / LL61#4K / LC61#4K

    Class F 320 406 402 350 425 415 370 442 437 435 545 520 485 567 540

    08/ 30007(E2)

    LSAM 47.2 VS2 / LL61#4B / LC61#4B LSAM 47.2 S4 / LL61#4D / LC61#4D LSAM 47.2 S5 / LL61#4D / LC61#4D LSAM 47.2 M7 / LL61#4F / LC61#4F LSAM 47.2 L9 / LL61#4K / LC61#4K

    Class H 355 450 443 380 475 456 405 500 480 476 602 580 535 630 605

    LSAM 49.1 S4 / LL70#4H / LC70#4H LSAM 49.1 M5 / LL70#4J / LC70#4J LSAM 49.1 M6 / LL70#4L / LC70#4L LSAM 49.1 M75 / LL70#4L / LC70#4L LSAM 49.1 L8 / NA / NA LSAM 49.1 L9 / LL70#4P / LC70#4P

    Class F 545 695 620 660 600 760 710 635 815 760 830 715 890

    LSAM 49.1 S4 / LL70#4H / LC70#4H LSAM 49.1 M5 / LL70#4J / LC70#4J LSAM 49.1 M6 / LL70#4L / LC70#4L LSAM 49.1 M75 / LL70#4L / LC70#4L LSAM 49.1 L8 / NA / NA LSAM 49.1 L9 / LL70#4P / LC70#4P

    Class H 600 740 690 732 660 800 786 710 855 840 934 800 1000

    http://www.cdlive.lr.org/information/

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    6 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    LSAM 50.2 S4 / LL82#4B / NA LSAM 50.2 M6 / LL82#4H / NA LSAM 50.2 L7 / LL82#4L / NA LSAM 50.2 L8 / LL82#4N / NA LSAM 50.2 VL10 / LL82#4P / NA

    Class F 900 1025 970 1055 1200 1090 1145 1285 - 1230 1400 1290 1365 1545 1450

    http://www.cdlive.lr.org/information/

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    7 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Leroy Somer ...continued LSAM 50.2 S4 / LL82#4B / NA LSAM 50.2 M6 / LL82#4H / NA LSAM 50.2 L7 / LL82#4L / NA LSAM 50.2 L8 / LL82#4N / NA LSAM 50.2 VL10 / LL82#4P / NA

    Class H 990 1125 1080 1140 1380 1220 1255 1480 - 1355 1600 1440 1495 1760 1625

    08/ 30007(E2)

    LSAM 51.2 S55 / LL91#4F / NA LSAM 51.2 M60 / LL91#4H / NA LSAM 51.2 L70 / LL91#4L / NA LSAM 51.2 VL80 / NA / NA LSAM 51.2 VL85 / LL91#4P / NA

    Class F 1555 1750 1835 1725 1945 2035 1855 2090 2120 2250 1940 2245

    LSAM 51.2 S55 / LL91#4F / NA LSAM 51.2 M60 / LL91#4H / NA LSAM 51.2 L70 / LL91#4L / NA LSAM 51.2 VL80 / NA / NA LSAM 51.2 VL85 / LL91#4P / NA

    Class H 1670 1925 2045 1895 2135 2270 2035 2290 2365 2505 2130 2460

    http://www.cdlive.lr.org/information/

  • Alternators (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    8 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    OM RON Corporation, Industrial Automation Company, Automation Systems Division, H.Q. Development Cente, Nishi-Kusatsu, Kusatsu-city, Shiga-pref, 525-0035, Japan.

    NA5-Series Programmable Terminal NA5-Series comprising: NA5-7W001S NA5-7W001B NA5-9W001S NA5-9W001B NA5-12W101B NA5-12W101S NA5-15W101B NA5-15W101S

    Marine, offshore and industrial control systems suitable for use in environmental categories ENV1, ENV2 and ENV3 in compliance w ith EMC categories in the “ Bridge and Deck Zone” as defined in LR Test Specification Number 1 July 2013, where the test specification is satisfactory for the intended operation.

    Expires: 10 February 2019 For use on the bridge and deck zone, additional power supply filter Schaffner FN-2080-XX is to be connected to the NA5-series power terminals.

    13/ 30003(E1)

    NA5-7U001S NA5-7U001B NA5-9U001S NA5-9U001B NA5-12U101S NA5-12U101B NA5-15U101S NA5-15U101B

    Additional Tests: IP65 enclosure test Low temperature test 4 hours at -5°C Oil proof test Corrosive gas test (H 2S 3ppm and SO2 10 ppm)

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    9 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    AEM - Anhaltische Elektromotorenwerk Dessau GmbH, Daheimstraße 18, 06842 Dessau - Roßlau, Germany.

    Automatic Voltage Regulator for Synchronous Alternators Types: Type R16 - Standard Version

    Manufacturer’s specification

    Frequency: R16: 25Hz to 75Hz R16-C: 30Hz to 60Hz R16-FV: 25Hz to 75Hz Phase: U – V Rated voltage ranges: Range 1: 230V to 450V Range 2: 380V to 710V Regulation accuracy: ±1%

    ENV1, ENV2, ENV4 (2002) Low temperature (-25C°/ 2 hours) Fire hazard testing acc. IEC 60695-11-5

    Expires: 8 July 2017

    12/ 20025

    Type R16-C - With power factor regulation component Type R16-FV -With frequency dependent voltage depression

    Static Phase: W Input: 1A; 2,5VA Range: 0% to 8% (cos(φ) = 0) Exciting voltage (DC): continuously - max. 250V for 10 sec. - max. 350V Exciting current (DC):

    continuously - max. 3A for 10 sec. - max. 15A External voltage regulation ±10% U internal : 0 - 10V or 4 -20mA for all three types Power factor regulation for R16-C: 0,6overexcited to 0,8underexcited

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    10 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Automatic Electric Europe B.V., Witte Paal 14, 1742 NL Schagen, Netherlands, The.

    Control transformer SP …… Single Phase, 5 VA up to and inclusive 10000VA TP ….. Three Phase, 5 VA up to and inclusive 25000VA

    NEN/ IEC 61558 Manufacturer’s Standard, T amb 45° C

    Marine, Industrial and Offshore applications

    Expires: 4 May 2021 13 March 2015

    06/ 30003(E2)

    Primary Voltage : 115V/ 480V, 50/ 60 Hz Secundary Voltage : Min. 12 V up to and inclusive 230V, 50/ 60 Hz

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    11 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Deif A/S, Frisenborgvej 33, 7800 Skive, Denmark.

    Engine controller and generator controller Types EC-1M

    Manufacturer’s specification

    Power supply (Vdc): 12 and 24 Input voltage (Vac): 50 - 550 Input frequency (Hz): 30 - 70 Relay outputs: 3 x 30Vdc/ AC 2A 2 x 30 Vdc/ AC8A

    ENV1, ENV2, ENV3 (2002) Low temperature (-25C°/ 16 hours) Enclosure IPX4 (display unit front)

    Expires: 8 November 2016

    06/ 20046(E1)

    1 x 24Vdc 1A (status relay)

    GC-1M

    Input voltage (Vac): 50 – 550 Input current (A): 1 or 5 Input frequency (Hz): 30 - 70 Relay outputs: 5 x 30Vdc/ AC 2A 2 x 30 Vdc/ AC8A 1 x 24Vdc 1A (status

    relay)

    Nishishiba Electric Co Ltd, Himeji, Japan.

    Type VZRAB-4A, VZRAB-5A, VZKUP-4 and VZKUP-4C

    Manufacturer’s Specification;- For VZRAB-4A: No.4E80938 Rev.(B), 4E80939 (B) For VZRAB-5A: No.4E80943 Rev.(A), 4E80947

    Output: Shunt current 10A max. Input: Voltage standard : 450V/ 380V Frequency standard : 60Hz/ 50Hz

    ENV1, ENV2, ENV3, ENV4 (2002)

    Expires: 1 October 2017 Adjustable range ±10% of rated voltage

    97/ 10023(E4)

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    12 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    For VZKUP-4: No. 4E80967 For VZKUP-4C: No. 4E90632

    Nishishiba Electric Co. Ltd., 1000 Hamada, Aboshi-ku, Himeji City, Hyogo Pref., Japan.

    Automatic Voltage Regulator (AVR) for A.C. Generator Type: VZRU-5

    Manufacturer’s Specification: No. 4E90660 Rev. C

    Power supply for control: 24V dc Output: Gate pulse signal to thyristor (out of scope of this certification) having output current 10 to 800A

    ENV2 ENV3 (2015) General Power Distribution Zones for EMC test

    Expires: 13 October 2021

    16/ 10016

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    13 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Nishishiba Electric Co. Ltd. ...continued

    Input voltage & frequency For generator voltage detection: 110V ac 3ph. 50/ 60Hz and other frequencies

    OTHER CONDITIONS (1) AVR and the associated thyristor shall be contained in a common or separate metal box having a necessary contrivance by which air temperature surrounding the product is maintained w ithin 5 to 55°C.

    16/ 10016

    For exciting power phase detection: 110V ac 3ph. 50/ 60Hz Voltage setting range: More tfan ±10% of rated voltage at no load

    2) A necessary provision for the associated equipment used together with AVR shall be so arranged as the ratio of harmonic distortion of the voltage waveform due to thyristor is fulfil led w ith the LR Rule requirements

    SANKO ELECTRIC CO LTD, 2-9-38, Shiraishi, Hiro, Kure City, Hiroshima Pref, 737-0143, Japan.

    Navigation Light Indicator & Signal Light Controller SNA Series Comprising:-

    - Manufacturer’s Specification No. SKD0123 dated 06 July 2009

    Power Supply: 110V a.c. / 220V a.c. and 24V d.c

    ENV 2 (2013) Additonal Test -Acoustic noise and signal test (IEC60945) -Compass safe distance measurement (IE60945) -Dry Heat Test 55C, 16 hours

    Expiries: 22 July 2019 Other Conditions: 1.The certificate attests to the hardware’s suitability for the environmental categories stated.

    09/ 10055(E1)

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    14 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Navigation Light Indicator : SNA-LP2 Signal Light Controller Consist of Signal Light Operation Panel: SNA-LC8 Signal Light Controller, 4ch: SNA-CR4

    - Adaption Of The Performance Standards For Navigation Lights, Navigation Light Controllers And Associated Equipment (IMO Resolution MSC.253(83)

    2. Suitability of the software and system configuration is subject to a separate plan appraisal according to the Lloyd’s Register Rules and Regulations when placed on Lloyd’s Register classed vessels.

    Signal Light Controller, 8ch: SNA-CR8 Current Monitoring P.C.B.: SNA-CS2 Power Unit: SNA-PSU

    3. It is noted that Hard polystyrene foam (Model :Styloace2, 3-b, Mfr.: Dow Chemical) and Rubber sponge (Model: NEO-5-40, Mfr.:KOWA) were attached all around inside the cover of

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    15 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    SANKO ELECTRIC CO LTD ...continued

    Metal Test box to reduce vibration resonance amplitude. Accordingly, the equivalent countermeasures are to be provided inside a panel or box on which the Navigation Light Indicator and/ or Signal Light Controller and/ is mounted.

    09/ 10055(E1)

    Taiyo Electric Co. Ltd, Gifu Works, 18 Kisaragi-cho, Kasamatsu-cho, Hashima-gun, Gifu-ken, Japan.

    Automatic Voltage Regulator Type: EXU-61 Series comprising:- EXU61 and EXU-61A

    Man spec. No. Z-635

    Output: 8A Input: 110, 225, 450V, 50/ 60Hz, 6VA max.

    ENV1 ENV2 ENV3 ENV4 (2013) in “ General Power Distribution Zones” Low temp at –25°C

    Expires: 21 June 2016

    01/ 10044(E3)

    Automatic Voltage Regulator Type: DST Series comprising:- DST – 162 and DST - 163

    Man spec. No. Z-733

    Output: DST-162 : 8Adc DST-163 : 20Adc Input: 110, 225, 450V, 50/ 60Hz, less than 2VA.

    ENV1 ENV2 ENV3 ENV4 (2013) in “ General Power Distribution Zones” Low temp at –25°C

    Expires: 13 November 2016

    06/ 10030(E2)

    http://www.cdlive.lr.org/information/

  • Automatic Voltage Regulators (Part 2)

    Producer/ Licence No. Type Standard Rating Category/ Additional Tests Remarks Cert. No.

    16 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Trafa B.V., Tussendonk 13, 4878 AM Etten Leur, Netherlands, The.

    STU 779040, 779063, 779100, 779160, 779250, 779400, 779630, 771000 and 771600

    IEC 60092, Tamb 45° C

    40, 63, 100, 160, 250, 400, 630, 1000 and 1600VA Primary Voltage 400 – 460 V ± 5% taps Secondary Voltage 115 – 230 V

    ENV 1, (2015)

    Expires: 2 March 2021

    06/ 30001(E3)

    STU690040, 690063, 690100, 690160, 690250, 690400, 690630, 691000 and 691600

    40, 63, 100, 160, 250,400, 630, 1000 and 1600VA Primary Voltage 690V Secondary Voltage 230V

    http://www.cdlive.lr.org/information/

  • Battery Chargers (Part 2)

    Producer/ Licence No. Item Description Technical Details Category/ Additional Tests Remarks Cert. No.

    17 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    M astervolt B.V., Snijdersbergweg 93, 1105 AN Amsterdam, Netherlands, The.

    Battery Chargers 230V 50-60 Hz Type Mass 24/ 75 C Type Mass 24/ 100 C

    Type Mass 24/ 75 C Input: 230V 50-60 Hz Output: 24V DC, 75A Three-step fully automatic charge characteristic Type Mass 24/ 100 C as above but output 24V DC, 100A

    ENV1 ENV2 (2002)

    Expires: 30 June 2015

    05/ 30015(E1)

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    18 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB AUSTRALIA Pty Limited, Bapaume Road, M oororebank, NSW 2170, Australia.

    Medium Voltage Vacuum Contactors Type V7/ ZVC

    CEI-IEC 60470: 2000 CEI-IEC 60694: 1996

    400

    7.2

    Breaking Making Capacity Capacity (kA) (kA) ------------ ------------ 4 4

    ENV1 ENV2 ENV3 (2002)

    Expires: 13 May 2015

    10/ 10080(E1)

    ABB S.p.A., Via Vittor Pisani, 16, M ilano, I -20124, I taly.

    E 90 Series Fuse Holder E 90 Series Switch Disconnector

    IEC 60269-1:2006, IEC 60269-3:2006 IEC 60947-3:1999 +A1:2001 + A2:2005

    20 A, 32 A 20 A-32 A

    400 V For use in environmental categories ENV 1 ENV 2 ENV 3 (2002)

    Expires: 1 April 2017

    12/ 00018

    ABB S.p.A. Power Products Division - Unità Operativa SACE M V, Via Friuli, 4, Dalmine 24044 (BG), I taly.

    Medium Voltage Vacuum Circuit Breakers Type:

    IEC 62271-1:2007 IEC 62271-100:2008

    [A]

    [kV] 50-60 Hz

    [kA] Breaking Peak Capacity Making Ics Ip

    ENV1 ENV2 ENV3 (2013)

    Expires: 30 December 2019

    04/ 00106(E3)

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    19 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    VD4/ P 12.06.32 VD4/ P 12.12.32 VD4/ P 12.16.32 VD4/ P 12.20.32 VD4/ P 12.25.32 VD4/ P 12.32.32

    630 1250 1600 2000 2500 3150

    12 12 12 12 12 12

    31.5 80 31.5 80 31.5 80 31.5 80 31.5 80 31.5 80

    VD4/ P 12.12.50 VD4/ P 12.16.50 VD4/ P 12.20.50 VD4/ P 12.25.50 VD4/ P 12.32.50

    1250 1600 2000 2500 3150

    12 12 12 12 12

    50 125 50 125 50 125 50 125 50 125

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    20 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB S.p.A. Power Products Division - Unità Operativa SACE M V ...continued

    VD4/ P 17.06.32 VD4/ P 17.12.32 VD4/ P 17.16.32 VD4/ P 17.20.32 VD4/ P 17.25.32 VD4/ P 17.32.32

    630 1250 1600 2000 2500 3150

    17 17 17 17 17 17

    31.5 80 31.5 80 31.5 80 31.5 80 31.5 80 31.5 80

    04/ 00106(E3)

    VD4/ P 17.12.50 VD4/ P 17.16.50 VD4/ P 17.20.50 VD4/ P 17.25.50 VD4/ P 17.32.50

    1250 1600 2000 2500 3150

    17 17 17 17 17

    50 125 50 125 50 125 50 125 50 125

    Medium Voltage SF6 (sulphur hexafluoride) Circuit Breakers Type

    IEC 62271-1:2007 IEC 62271-100 :2008

    [A]

    [kV] 50-60 Hz

    [kA] Breaking Peak Capacity Making Ics Ip

    ENV1 ENV2 ENV3 (2013)

    Expires: 1 June 2020

    09/ 00042(E1)

    HD4-DRS 12.12.32

    1250

    12

    31.5 80

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    21 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Medium Voltage Vacuum Insulated Circuit Breaker Type: Vmax/ Sec 12.06.16 Vmax/ Sec 12.06.20

    IEC 62271-100:2003

    630A 630A

    12Kv 12kV

    Breaking Making Capacity Capacity Isc (kA) Ip (kA) 16 42 20 52

    ENV3 (2002)

    Expires: 3 September 2019

    14/ 00067

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    22 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB S.p.A. Power Products Division - Unità Operativa SACE M V ...continued

    Vmax/ Sec 12.06.25 Vmax/ Sec 12.12.16 Vmax/ Sec 12.12.20 Vmax/ Sec 12.12.25 Vmax/ Sec 17.06.16 Vmax/ Sec 17.06.20 Vmax/ Sec 17.06.25 Vmax/ Sec 17.12.16 Vmax/ Sec 17.12.20 Vmax/ Sec 17.12.25

    630A 1250A 1250A 1250A 630A 630A 630A 1250A 1250A 1250A

    12kV 12kV 12kV 12kV 17,5kV 17,5kV 17,5kV 17,5kV 17,5kV 17,5kV

    25 65 16 42 20 52 25 65 16 42 20 52 25 65 16 42 20 52 25 65

    14/ 00067

    ABB S.p.A. Power Products Division, Unita Operativa Sace-M V, Via Friuli 4, 24044 - Dalmine (BG), I taly.

    Medium Voltage SF6 (sulphur hexafluoride) Circuit Breakers Type:

    IEC 62271-1:2007 IEC 62271-100 :2008

    [A]

    [kV] 50-60 Hz

    [kA] Breaking Peak Capacity Making Ics Ip

    ENV1 ENV2 ENV3 (2013)

    Expires: 20 April 2020

    15/ 00032

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    23 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    HD4/ P 12.06.32 HD4/ P 12.12.32 HD4/ P 12.16.32 HD4/ P 12.20.32 HD4/ P 12.25.32 HD4/ P 12.32.32 HD4/ P 12.12.40 HD4/ P 12.16.50 HD4/ P 12.20.50 HD4/ P 12.25.50

    630 1250 1600 2000 2500 3150 1250 1600 2000 2500

    12 12 12 12 12 12 12 12 12 12

    31.5 80 31.5 80 31.5 80 31.5 80 31.5 80 31.5 80 40 100 50 125 50 125 50 125

    HD4/ P 12.32.50 HD4/ C 12.06.32 HD4/ C 12.12.32 HD4/ C 12.16.32 HD4/ C 12.25.32 HD4/ C 12.16.50 HD4/ C 12.25.50

    3150 630 1250 1600 2500 1600 2500

    12 12 12 12 12 12 12

    50 125 31.5 80 31.5 80 31.5 80 31.5 80 50 125 50 125

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    24 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB S.p.A. Power Products Division, Unita Operativa Sace-M V ...continued

    HD4/ W 12.06.32 HD4/ W 12.12.32 HD4/ W 12.16.32 HD4/ W 12.20.32 HD4/ W 12.25.32 HD4/ W 12.32.50

    630 1250 1600 2000 2500 3150

    12 12 12 12 12 12

    31.5 80 31.5 80 31.5 80 31.5 80 31.5 80 50 125

    15/ 00032

    ABB Sace S.p.A, Via Enrico Fermi 14, Frosinone 03100, I taly.

    3 and 4 poles moulded case circuit breakers, fixed or plug-in Type: Tmax T1 Tmax T2 Tmax T3

    IEC 60947-1 :2007 +A1+A2 IEC 60947-2:2006 +A1+A2

    [kA] Icu Ics Icm

    ENV 1 ENV 2 ENV 3 (2002)

    Expires: 12 March 2022

    02/ 00005(E2) 02/ 00005(E3)

    T1C

    160 R25-R160

    440 690

    15 11.25 30 4 3 5.9

    T1N

    160 R32-R160

    440 690

    22 11 46.2 6 3 9.2

    T2N

    160 R25-R160

    440 690

    30 30 63 6 6 9.2

    T2S

    160 R25-R160

    440 690

    45 45 94.5 7 7 11.9

    T2H

    160 R25-R160

    440 690

    55 55 121 8 8 13.6

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    25 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    T2L

    160 R25-R160

    440 690

    75 56.25 165 10 7.5 17

    T3N

    250 R63-R250

    440 690

    25 18.75 52.5 5 3.75 7.7

    T3S 250 R63-R250

    440 690

    40 20 84 8 4 13.6

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    26 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    moulded case circuit breakers Series: TMAX T4 TMAX T5 Type:

    IEC 60947-1 :2007 +A1+A2 IEC 60947-2:2006 +A1+A2

    [A]

    [V] 50-60 Hz

    [kA] Icu Ics Icm Icw

    Category A Category B (T5 400) ENV1 ENV2 ENV3 (2013)

    Expires: 3 February 2020

    05/ 00013(E3)

    T4 N 250 T4 S 250 T4 H 250

    250 250 250

    440 690 440 690 440 690

    0.25 0.25 0.25 0.25 0.2 0.25

    30 30 63 20 20 40 40 40 84 25 25 52.5 65 65 143 40 40 84

    Low Temperature test (-25-°C)

    Trip Unit: equipped with thermomagnetic or electronic release Electronic Release: PR 221 DS PR 222 DS/ PD PR 222 MPS PR 223 EF/ DS

    T4 L 250 T4 V 250

    250 250

    440 690 440 690

    0.2 0.2 0.2 0.2

    100 100 220 70 70 154 180 180 396 80 80 176

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    27 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    T4 N 320 T4 S 320 T4 H 320

    320 320 320

    440 690 440 690 440 690

    0.25 0.25 0.25 0.25 0.2 0.25

    30 30 63 20 20 40 40 40 84 25 25 52.5 65 65 143 40 40 84

    Thermomagnetic Release: TMD TMA MA TMG

    T4 L 320 T4 V 320

    320 320

    440 690 440 690

    0.2 0.2 0.2 0.2

    100 100 220 70 70 154 180 180 396 80 80 176

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    28 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    T5 N 400 T5 S 400 T5 H 400

    400 400 400

    440 690 440 690 440 690

    0.25 0.25 0.25 0.25 0.2 0.25

    30 30 63 5 20 20 40 5 40 40 84 5 25 25 52.5 5 65 65 143 5 40 40 84 5

    05/ 00013(E3)

    T5 L 400 T5 V 400

    400 400

    440 690 440 690

    0.2 0.2 0.2 0.2

    100 100 220 5 70 70 154 5 180 180 396 5 80 80 176 5

    T5 N 630 T5 S 630 T5 H 630

    630 630 630

    440 690 440 690 440 690

    0.25 0.25 0.25 0.25 0.2 0.25

    30 30 63 20 20 40 40 40 84 25 25 52.5 65 65 143 40 30 84

    T5 L 630 T5 V 630

    630 630

    440 690 440 690

    0.2 0.2 0.2 0.2

    100 100 220 70 35 154 180 180 396 80 40 176

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    29 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A, Via Biaoni 35, 24123 Bergamo, I taly.

    3 pole moulded case circuit breakers Type

    IEC 60947-1 IEC 60947-2

    (kA) Icu Ics Icm Icw

    ENV1 ENV2 ENV3 (2013)

    Expires: 24 March 2022

    07/ 00018(E3)

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    30 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    T6 N 630 T6 S 630

    630 630

    380/ 415 440 690 380/ 415 440 690

    36 36 75.6 30 30 63 20 15 40 7.6 50 50 105 45 45 94.5 22 17 46 7.6

    Trip Unit: equipped with thermomagnetic and electronic release Thermomagnetic Release: TMA

    07/ 00018(E3)

    T6 H 630 T6 L 630

    630 630

    380/ 415 440 690 380/ 415 440 690

    70 70 154 50 50 105 25 19 52.5 7.6 100 75 220 80 60 176 30 23 63 7.6

    Electronic Release: PR 221 DS PR 222 DS PR 223 DS PR 222 MP PR 223 EF

    T6 N 800 T6 S 800

    800 800

    380/ 415 440 690 380/ 415 440 690

    36 36 75.6 30 30 63 20 15 40 10 50 50 105 45 45 94.5 22 17 46 10

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    31 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    T6 H 800 T6 L 800

    800 800

    380/ 415 440 690 380/ 415 440 690

    70 70 154 50 50 105 25 19 52.5 10 100 75 220 80 60 176 30 23 63 10

    ABB Sace S.p.A, Via Enrico Fermi 14, Frosinone 03100, I taly.

    moulded case circuit breakers Series: TMAX T7 Type:

    IEC 60947-1 :2007 +A1+A2 IEC 60947-2:2006 +A1+A2

    [A]

    [V] 50-60 Hz

    [kA] Icu Ics Icm Icw

    Category B ENV1 ENV2 ENV3 (2013)

    Expires: 25 March 2020

    10/ 00023(E1)

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    32 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    T7 S 800 T7 H 800 T7 L 800

    800 800 800

    440 690 440 690 440 690

    0.25 0.25 0.2 0.25 0.2 0.25

    50 50 105 20 30 30 63 20 65 65 143 20 42 31.5 88.2 20 100 100 220 20 50 37.5 105 20

    Low Temperature test (-25-°C)

    Trip Unit: equipped with thermomagnetic or electronic release Electronic Release: PR 231/ P PR 232/ P PR 331/ P

    10/ 00023(E1)

    T7 V 800

    800

    440 690

    0.2 0.2

    130 130 286 15 60 45 132 15

    PR 332/ P

    T7 S 1000 T7 H 1000 T7 L 1000

    1000 1000 1000

    440 690 440 690 440 690

    0.25 0.25 0.2 0.25 0.2 0.25

    50 50 105 20 30 30 63 20 65 65 143 20 42 31.5 88.2 20 100 100 220 20 50 37.5 105 20

    T7 V 1000

    1000

    440 690

    0.2 0.2

    130 130 286 15 60 45 132 15

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    33 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    T7 S 1250 T7 H 1250 T7 L 1250

    1250 1250 1250

    440 690 440 690 440 690

    0.25 0.25 0.2 0.25 0.2 0.25

    50 50 105 20 30 30 63 20 65 65 143 20 42 31.5 88.2 20 100 100 220 20 50 37.5 105 20

    T7 V 1250

    1250 440 690

    0.2 0.2

    130 130 286 15 60 45 132 15

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    34 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    T7 S 1600 T7 H 1600 T7 L 1600

    1600 1600 1600

    440 690 440 690 440 690

    0.25 0.25 0.2 0.25 0.2 0.25

    50 50 105 20 30 30 63 20 65 65 143 20 42 31.5 88.2 20 100 100 220 20 50 37.5 105 20

    10/ 00023(E1)

    ABB Sace S.p.A, Via Biaoni 35, 24123 Bergamo, I taly.

    Moulded case circuit breakers

    IEC 60947-1: 2007 +A1+A2 IEC 60947-2: 2006 +A1+A2

    (A)

    (V) 50-60 Hz

    (V)

    (kA) Icm Icu Ics

    ENV1 ENV2 ENV3 (2013) Low Temperature test (-25 °C, 16h)

    Expires: 9 October 2017 Place of Production: ABB S.p.A. via Enrico Fermi, 14 03100 Frosinone, Italy

    12/ 00065(E1)

    Type: Tmax XT1 B C N S H

    160 “ “ “ “

    240 “ “ “ “

    0,19 “ “ “ “

    25 25 52.5 40 40 84 65 50 143 85 64 187 100 75 220

    Trip Unit equipped with thermomagnetic relaease TMF/ TMD

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    35 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    B C N S H

    “ “ “ “ “

    440 “ “ “ “

    0,18 “ “ “ “

    15 15 30 25 13 52.5 36 18 75.6 50 25 105 65 33 143

    B C N S H

    “ “ “ “ “

    690 “ “ “ “

    0,48 “ “ “ “

    3 3 4.26 4 4 5.88 6 4 9.18 8 4 13.6 10 5 17

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    36 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    B C N S H

    160 “ “ “ “

    250 “ “ “ “

    15.2 ms “ “ “ “

    18 18 - 25 25 - 36 36 - 50 50 - 70 53 -

    12/ 00065(E1)

    B C N S H

    “ “ “ “ “

    500 “ “ “ “

    15 ms “ “ “ “

    18 18 - 25 25 - 36 36 - 50 50 - 70 53 -

    Trip Unit: equipped with: thermomagnetic release TMD/ TMA or Ekip

    Tmax XT2 N S H L V

    160 “ “ “ “

    240 “ “ “ “

    0.19 “ “ “ “

    65 65 143 85 85 187 100 100 220 150 150 330 200 200 440

    microprocessor based electronic releases (AC only) software version 1.20 (Ekip LSI and LSIG), 2.07 (Ekip LS/ I, Ekip LS,

    N S H L V

    “ “ “ “ “

    440 “ “ “ “

    0.19 “ “ “ “

    36 36 75.6 50 50 105 65 65 143 100 100 220 150 150 330

    Ekip I, Ekip M-LIU).

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    37 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    N S H L V

    “ “ “ “ “

    690 “ “ “ “

    0.29 “ “ “ “

    10 10 17 12 12 24 15 15 30 18 18 36 20 15 40

    N S H L V

    160 “ “ “ “

    250 “ “ “ “

    15 ms “ “ “ “

    36 36 - 50 50 - 70 70 - 85 85 - 100 100 -

    N S H L V

    “ “ “ “ “

    500 “ “ “ “

    16.6 ms “ “ “ “

    36 36 - 50 50 - 70 70 - 85 85 - 100 100 -

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    38 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    Tmax XT3 N S N

    250 “ “

    440 “ 690

    0.21 0.23 0.7

    25 19 52.5 40 20 84 5 4 7.65

    Trip Unit: equipped with: thermomagnetic release TMD

    12/ 00065(E1)

    N S N S

    250 “ “ “

    250 “ 500 “

    15.8 ms “ 15.8 ms “

    36 36 - 50 50 - 36 36 - 50 50 -

    Tmax XT4 N S H L V

    250 “ “ “ “

    240 “ “ “ “

    0.14 “ “ “ “

    65 65 143 85 85 187 100 100 220 150 150 330 200 200 440

    Trip Unit: equipped with: thermomagnetic release TMD/ TMA or Ekip microprocessor

    N S H L V

    “ “ “ “ “

    440 “ “ “ “

    0.19 “ “ “ “

    36 36 75.6 50 50 105 65 65 143 100 100 220 150 150 330

    based electronic releases (AC only) software version 1.20 (Ekip LSI and LSIG), 2.07 (Ekip LS/ I, Ekip LS,

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    39 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    N S H L V

    “ “ “ “ “

    690 “ “ “ “

    0.21 “ “ “ “

    10 10 17 12 12 24 15 15 30 20 20 40 25 20 52.5

    Ekip I, Ekip M-LIU).

    N S H L V

    250 “ “ “ “

    250 “ “ “ “

    16.6 ms “ “ “ “

    36 36 - 50 50 - 70 70 - 85 85 - 100 100 -

    N S H L V

    “ “ “ “ “

    500 “ “ “ “

    16.6 ms “ “ “ “

    36 36 - 50 50 - 70 70 - 85 85 - 100 100 -

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    40 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    Low Voltage air circuit breakers

    IEC 60947-1: 2011 IEC 60947-2: 2006/ A1:2009

    (kA) Icm Icu Ics

    ENV1 ENV2 ENV3 (2002)

    Expires: 8 May 2019 Additional test: Low Temperature, -25°C ±2.5°C for 16 hours

    14/ 00032

    Type: Emax E1.2 B-C-N equipped with Electronic releases Ekip DIP, Ekip LCD, Ekip Touch, Ekip Hi.LCD, Ekip Hi-Touch, Ekip G Hi-Touch

    400-1600

    400-415 440 500-525 690

    0,23 0,23 0,23 0,23

    88,2/ 145,2 42/ 50 42/ 66 88,2/ 145,2 42/ 50 42/ 66 88,2/ 105 42/ 50 42/ 50 88,2/ 105 42/ 50 42/ 50

    Place of Production: ABB S.p.A. via Enrico Fermi, 14 03100 Frosinone, Italy

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    41 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    Emax E2.2 B-N-S-H equipped with Electronic releases Ekip DIP, Ekip LCD, Ekip Touch, Ekip Hi.LCD, Ekip Hi-Touch, Ekip G Hi-Touch

    400 - 2000 (B) - 2500 (N-S-H)

    400-415 440 500-525 690

    0,18 0,18 0,18 0,18

    88,2/ 220 42/ 100 42/ 100 88,2/ 220 42/ 100 42/ 100 88,2/ 187 42/ 85 42/ 85 88,2/ 187 42/ 85 42/ 85

    software versions: v01.07.00 (Ekip DIP), v01.08.03 (Ekip (Hi) LCD and Ekip (G) (Hi) Touch)

    Emax E4.2 N-S-H-V equipped with Electronic releases Ekip DIP, Ekip LCD, Ekip Touch, Ekip Hi.LCD, Ekip Hi-Touch, Ekip G Hi-Touch

    400-4000 400-415 440 500-525 690

    0,16 0,16 0,16 0,16

    145,2/ 330 66/ 150 66/ 150 145,2/ 330 66/ 150 66/ 150 145,2/ 220 66/ 100 66/ 100 145,2/ 220 66/ 100 66/ 100

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    42 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    Emax E6.2 H-V equipped with Electronic releases Ekip DIP, Ekip LCD, Ekip Touch, Ekip Hi.LCD, Ekip Hi-Touch, Ekip G Hi-Touch

    400-6300

    400-415

    440

    500-525

    690

    0,18

    0,18

    0,18

    0,18

    220/ 330 100/ 150 100/ 150

    220/ 330 100/ 150 100/ 150

    220/ 286 100/ 130 100/ 130

    220 100

    100

    14/ 00032

    EMAX Series 3 pole air circuit breakers

    IEC 60947-1 IEC 60947-2 Category B

    ABB SpA - ABB Sace Division, Via Baioni, 35, 24123 Bergamo, Italy.

    (A) rms breaking (kA) Icu/ Ics (B) peak making (kA)

    ENV1 ENV2 ENV3 (1996)

    Expires: 18 May 2018

    98/ 00073(E7)

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    43 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    EI B 800 EI B 1250

    250 - 800 250 - 1250

    440 690 440 690

    0.25 0.25 0.25 0.25

    (B) (A) 94.5 45/ 36 75.6 36/ 36 94.5 45/ 36 75.6 36/ 36

    Low temperature test (- 25°C)

    Units fitted w ith PR 111, PR112, PR113, PR121, PR122 and PR123 microprocessor based overcurrent

    E1 N 800 E1 N 1000 E1 N 1250 E1 N 1600

    “ “ “ “

    400 - 800 400 - 1000 400 - 1250 400 - 1600

    440 690 440 690 440 690 440 690

    0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25

    105 50/ 50 105 50/ 50 105 50/ 50 105 50/ 50 105 50/ 50 105 50/ 50 105 50/ 50 105 50/ 50

    E2 B 1600 E2 B 2000

    “ “

    250 - 1600 250 - 2000

    440 690 440 690

    0.25 0.25 0.25 0.2

    75.6 36/ 36 94.5 45/ 45 94.5 45/ 45 94.5 45/ 45 94.5 45/ 45

    protection release providing against overload, short circuit and earth faults

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    44 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    E2 L 1250 E2 L 1600 E3 L 2000 E3 L 2500

    Category A “ “ “

    250 - 1250 250 - 1600 250 - 2000 250 - 2500

    440 690 440 690 440 690 440 690

    0.25 0.25 0.2 0.2 0.2 0.2 0.2 0.2

    242 110/ 110 187 85/ 65 187 85/ 65 242 110/ 110 242 110/ 110 187 85/ 65 187 85/ 65 187 85/ 65

    98/ 00073(E7)

    E2 N 1000 E2 N 1250 E2 N 1600 E2 N 2000

    Category B “ “ “

    400 - 1000 250 - 1250 250 - 1600 250 - 2000

    440 690 440 690 440 690 440 690

    0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2

    143 65/ 65 121 55/ 55 143 65/ 65 122 55/ 55 143 65/ 65 121 55/ 55 143 65/ 65 121 55/ 55

    E2 S 800 E2 S 1000 E2 S 1250

    Category B “ “

    400 - 800 400 - 1000 400 - 1250

    440 690 440 690 440 690

    0.2 0.2 0.2 0.2 0.2 0.2

    (B) (A) 187 85/ 85 143 65/ 65 187 85/ 85 143 65/ 65 187 85/ 85 143 65/ 65

    E2 S 1600 E2 S 2000

    “ “

    400 - 1600 400 - 2000

    440 690 440 690

    0.2 0.2 0.2 0.2

    187 85/ 85 143 65/ 65 187 85/ 85 143 85/ 85

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    45 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    E3 N 2500 E3 N 3200 E3 S 1250

    Category B “ “

    250 - 2500 250 - 3200 250 - 1250

    440 690 440 690 440 690

    0.2 0.2 0.2 0.2 0.2 0.2

    143 65/ 65 143 65/ 65 143 65/ 65 143 65/ 65 187 85/ 85 165 75/ 75

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.

    46 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's

    Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

    http://www.cdlive.lr.org/information/

    ABB Sace S.p.A ...continued

    E3 S 1000 E3 S 1600 E3 S 2000 E3 S 2500 E3 S 3200

    “ “ “ “ “

    400 - 1000 250 - 1600 250 - 2000 250 - 2500 250 - 3200

    440 690 440 690 440 690 440 690 440 690

    0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2

    187 85/ 85 165 75/ 75 187 85/ 85 165 75/ 75 187 85/ 85 165 75/ 75 187 85/ 85 165 75/ 75 187 85/ 85 165 75/ 75

    “ 98/ 00073(E7)

    E3 H 800 E 3H 1000 E3 H 1250 E3 H 1600

    “ “ “

    400 - 800 400 - 1000 250 - 1250 250 - 1600

    440 690 440 690 440 690 440 690

    0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2

    220 100/ 85 187 85/ 85 220 100/ 85 187 85/ 85 220 100/ 85 187 85/ 85 220 100/ 85 187 85/ 85

    E3 H 2000 E3 H 2500 E3 H 3200

    “ “ “

    250 - 2000 250 - 2500 250 - 3200

    440 690 440 690 440 690

    0.2 0.2 0.2 0.2 0.2 0.2

    220 100/ 85 187 85/ 85 220 100/ 85 187 85/ 85 220 100/ 85 187 85/ 85

    http://www.cdlive.lr.org/information/

  • Circuit Breakers (ENV Tested) (Part 2)

    Rating

    Producer/ Normal A.C. D.C. Category/

    Licence No. Type Standard Current Amperes Voltage Power Factor Voltage

    Time Constant Seconds

    Short Circuit Additional Tests Remarks Cert. No.