alpu-alvr-ul 497 primary surge protector - streakwave ... · alpu-alvr applications wireless...
TRANSCRIPT
ALPU-ALVR
ApplicationsWireless Broadband Networks
• WiMAX
• WiFi
• MESH
• Wireless Backhaul
The ALPU-ALVR is purpose built for Alvarion WiMAX and WiFi Ethernet radios and meets the new UL 497 standards. ALPU-ALVR is the premier primary and secondary protector for your high-speed packet network equipment from lightning and other transients. It is the only Alvarion UL 497 listed protector for primary protection. The ALPU-ALVR has low capacitance/impedance and insertion loss so that your packets will reach their destination without disruption from your surge protection system. The ALPU-ALVR is configured with three types of surge protection: silicon diodes for over-voltage, fuses for power line cross, and PTC (positive temperature coefficient) fuses for sneak current.
UL 497 Listed - Primary - Advanced Lightning Protection Unit for 55V WiMAX & Power Over Ethernet Applications
208.772.8515 800.882.9110 FAX 208.762.613310701 N. Airport Road, Hayden, ID 83835
www.transtector.com [email protected] ISO 9001:2000 and 14001 Certified Company
ALPU-ALVRConfigurations
Features• Surge Protection - over voltage, sneak current and fault current• Minimal capacitance/low impedance • Purpose-built for Alvarion broad- band wireless equipment • 100 percent, non-degrading silicon suppression• Appropriate for primary and secondary protection
WarrantyFive (5) year unconditional warrantyTen (10) year manufacturer’s warranty
1453-036 Rev. A
Installation
DataService VoltageCable Entry/Exit
Part Number
Voltage Protection Level
Response Time (Max.)
Operating Temperature<5 Nanoseconds
-40° to +80°C
2 Ethernet
55VDC
2
1101-640
130Vpk @ 150A 10/1000μs152Vpk @ 1500A 8/20μs
Max. Cont. Operating 90VDC
Max. Cont. Current 1 AMP
Alvarion Radio Models BreezeMax
BreezeAccess
BreezeNet
This product is available through Transtector distributors Anixter, Hutton, Tessco and WinnCom.
Remove the cover by loosening the four captive cover screws using a Phillips screwdriver. Mount the ALPU-ALVR as close to the equipment to be protected as possible using the provided hardware and the concealed mounting holes. Mount the unit in the orientation shown.
Thread a multiconductor cable from the data source through the strain relief adjacent to the marking on the PCB labeled “Input.”
Strip back the cable jacket as needed, then install the conductors into the IDC connectors labeled “Input” - place the wires into the grooves in the connector, leaving approximately 1/8” of wire overhanging, and press down firmly with the punch-down tool until the wires firmly engage into the fork terminals.
Repeat this procedure for the outgoing multiconductor cable, using the connectors labeled “Output.
Tighten the strain reliefs to secure the cables (DO NOT OVER TORQUE!). Replace the cover.
Dimensions:6.5”h X 4.7”w X 2.6”d13.9 cm X 12.1 cm X 6.6 cm
UL 497 ListedPrimary Surge Protector
CONCEALEDMOUNTING HOLES
EXTERNAL GND LUGACCEPTS 4-14 AWG
STRAIN RELIEF ACCEPTSCABLE DIA. RANGE0.250" THRU 0.375"
+ D A TA D C +-D A TA D C ++ D A TA D C --D A TA D C -D C 4 TX +D C 5 TX -D C 7 R X +D C 8 R X -
TE R M IN A L / P O ST D E SC R IP T IO N12345678
D C 2 (-)D C 2 (-)D C 2 (-)D C 2 (-)D C 2 (-)D C 2 (-)D C 2 (-)D C 2 (-)
TA B LE 1IN P U T/O U TP U T W IR IN G U S IN G ID C TE R M IN A L STR IP S