alkco is a philips group brand - dickman supplydownloads.dickmansupply.com/pdf/alkco/eracare.pdf ·...
TRANSCRIPT
is an integrated lighting solution for
the patient room environment. It fulfills the requirements
for Examination, Reading and Ambient lighting
whilealsosimplifyingtheday-to-dayeffortsofthehealthcare
professionalandfacilitymaintenancestaff.Everyaspectofthe
designisfocusedoneaseofuse.Patientsandstaffalikewant
thebestincareandERAcare™canhelpmeetthoseexpectations.
ERAcare ™
• ERAcare™ delivers the recommended illumination levels for patient reading.
• The patient’s visual comfort is enhanced by the soft, indirect ambient lighting.
• There are a variety of switching options for patient ease-of-use.
• Optical compartments are positioned to minimize glare.
• ERAcare™ has no moving parts that need to be flipped or rotated.
• From its soft form to its antimicrobial finish, ERAcare™ is designed to compliment infectious control efforts.
• The recommended illumination levels for examination are met.
• LED night/chart lights and switches are positioned at either end of the luminaire and can be controlled individually or together.
• The snap-in lenses provide tool-less lamp replacement.
• An optional bed shut-off switch minimizes the potential for luminaire damage from motorized patient beds.
• A removable ballast tray provides quick access to key electrical components.
c a r e f o r t h e
c a r e f o r t h e
c a r e f o r t h e
p a t i e n t
h e a l t h c a re p ro f e s s i o n a l
f a c i l i t y s t a f f
2 www.alkco.com
Function Recommended Levels1 ERAcare™ Levels
Exam
Reading
Ambient
1 Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities.2 Achieved with utilizing the exam and reading optical compartments.3 Achieved with utilizing the exam optical compartments only.
I n t e g r a t e d O p t i c a l S o l u t i o n s
Illuminationofthepatientbedforexamination
IlluminationofboththehorizontalandangledreadingplanesGeneralroomillumination
112Avg.Footcandles2
80Avg.Footcandles3
65Avg.Footcandles(horizontal)54Avg.Footcandles(angled)12Avg.Footcandles
50-100Avg.Footcandles
20-50Avg.Footcandles
5-10Avg.Footcandles
ERAcare™ utilizes four separate optical compartments to
providethreekeyilluminationrequirementsforthepatient
room–Exam,ReadingandAmbient.Thesevaried functions
are integrated into a compact cross-section and can be
activated without the need to flip, rotate or mechanically
move any part of the luminaire. The needs of the patient
andhealthcarestaffareaflipoftheswitchaway.
Ambient
Reading
Front Exam Rear Exam
Lamp CompartmentsA
A
B
BC
C
D
D
LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20
3www.alkco.com
P ro d u c t D e t a i l s
• Thediecastendcapsandextrudedaluminum housingprovidesdurability.
• Internallinearprismshelpmaintainasmooth exteriorsurfacethatiseasytowipedown.
• ERAcare’sdualexamopticalcompartments promotebetteruniformityacrosstheentire patientbedsurface.
• Multipleswitchingoptionsareavailabletomeet theneedsoftheinstallation.
• The removable socket covers conceal the lamp socket and promote a uniform appearance of the illuminated lens.
• The positive snap-in lenses provide tool-less lamp replacement.
• A removable ballast tray provides convenient access to key electrical components.
• ERAcare™isavailableinfourstandardfinishes– allwithanantimicrobialadditivetoinhibitthe growthofmicrobesforthelifeoftheproduct.
1
5
1
2
2
3
3
3
4
4
5
• Thesmallcross-section helpsERAcare™blend intothepatientroom environment.
• Thesoftcurvedform eliminatessharpcorners, simplifiescleaningand reducesvisualsize.
• Noflatsurfacestosititemson.
• TheBedShut-offSwitchoptionminimizesthe potentialforluminairedamagefrommotorized patientbedsbydisconnectingpowertothebed whenERAcare™ismoved.
• Asanoption,asetofintegratedLEDchart/night lightsarelocatedateitherendoftheluminaire. Healthcarestaffcanconvenientlyoperatethese lowlevellightsfrombothsidesofthepatientbed.
• ERAcare™meetsthemoststringentillumination recommendationsforexamandreadingfunctions. Seechartonpage2.
ERAcare™canbecomplimentedwithAlkco’s WayGlo™LEDNightLights.Formoreinformation onWayGlo™orotherAlkco®Healthcaresolutions, gotowww.alkco.comorcontactyourlocalAlkco® representative.
Soft White Taupe Aluminum Almond WG1H WG1V WG2H WG2V
8-15/16”(227.3mm)
5-1/2”(139.7mm)
A m b i e n t
(1)54WT5HOFluorescent*4450lumensperlamp*Testingambientlamponly.
ReportNo.: ITL60756ModelNo.: ECT5HOEfficiency: 80.9%
LEGEND: 0-deg: 45-deg:
90-deg:
1800
1200
600
180˚ 165˚ 150˚
90˚
105˚
120˚
135˚
Illumination values calculated at 30” AFF.
ERAcare™ Candela Distribution
Patient Room View
Room Parameters
RoomSize: 12’x12’CeilingHt.: 8’-6”
LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20
Ambient Illumination Level
Recommended Level* (Avg. Footcandles) 5-10
* RecommendationsarefromANSI/IESNARP-29-06,AnIESNARecommended Practice,LightingforHospitalsandHealthCareFacilities
** Achievedutilizingtheambientopticalcompartmentwith(1)F54T5HOlamp.
Visitwww.alkco.comforcompletePhotometricData
ERAcare™
(Avg. Footcandles) 12**
11.0 13.1 15.4 17.5 19.2 20.2 20.2 19.2 17.5 15.4 13.1 11.0
12.1 14.4 16.9 19.3 21.2 22.3 22.3 21.2 19.3 16.9 14.5 12.1
12.4 14.8 17.2 19.5 21.4 22.5 22.5 21.4 19.5 17.2 14.8 12.4
12.0 14.2 16.4 18.5 20.1 21.1 21.0 20.1 18.5 16.4 14.2 12.0
11.2 13.1 14.9 16.6 18.0 18.7 18.7 18.0 16.6 14.9 13.0 11.1
10.0 11.6 13.1 14.4 15.5 16.0 16.0 15.5 14.4 13.1 11.6 10.0
8.8 10.1 11.2 12.2 13.0 13.4 13.4 13.0 12.2 11.2 10.0 8.8
7.6 8.6 9.5 10.3 10.8 11.1 11.1 10.8 10.3 9.5 8.6 7.6
6.6 7.4 8.0 8.6 9.0 9.3 9.2 9.0 8.6 8.0 7.3 6.6
5.7 6.3 6.8 7.3 7.6 7.8 7.8 7.6 7.3 6.8 6.3 5.7
5.0 5.5 5.9 6.3 6.5 6.6 6.6 6.5 6.2 5.9 5.5 4.9
4.4 4.8 5.2 5.5 5.7 5.8 5.8 5.7 5.5 5.2 4.8 4.4
4 www.alkco.com
Room Parameters
Room Size: 12’ x 12’Ceiling Ht.: 8’-6”
Luminaire Mtg. Ht.: 6’ AFFRoom Reflectances: 80/50/20
Exam Illumination Level (Patient bed positioned 30” AFF)
Recommended Level* (Avg. Footcandles) 50-100
* Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities** Achieved utilizing the exam and reading optical compartments with (3) F54 T5HO lamps*** Achieved utilizing the exam optical compartments with (2) F54 T5HO lamps
Visit www.alkco.com for complete Photometric Data
ERAcare™
(Avg. Footcandles) 112** 80***
E x a m
(3) 54W T5HO Fluorescent*4450 lumens per lamp* Testing 3 lamps (exam and reading).
Report No.: ITL60757Model No.: ECT5HOEfficiency: 64.1%
LEGEND: 0-deg: 45-deg:
90-deg:
1300
2600
3900
0˚ 15˚ 30˚
45˚
60˚
75˚
90˚
ERAcare™ Candela Distribution
Detail of Exam SurfacePatient Room View
Luminaire Mtg. Ht.: 6’ AFFRoom Reflectances: 80/50/20
5 www.alkco.com
156183
194
155183
187219
231
186219
168131
97.770.5
51.438.6
30.1
194148
10876.6
54.840.6
31.3
204154
11278.8
56.141.3
31.7
168131
97.670.4
51.338.6
30.0
194148
10876.5
54.840.6
31.7
Exam Surface
Room Parameters
RoomSize: 12’x12’CeilingHt.: 8’-6”
Detail of Horizontal Reading Surface
LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20
Reading Illumination Level (Horizontal Plane)
Recommended Level* (Avg. Footcandles) 20-50
* RecommendationsarefromANSI/IESNARP-29-06,AnIESNARecommended Practice,LightingforHospitalsandHealthCareFacilities
** Achievedutilizingthereadingopticalcompartmentwith(1)F54T5HOlamp.
Visitwww.alkco.comforcompletePhotometricData
ERAcare™
(Avg. Footcandles) 65**
H o r i z o n t a l R e a d i n g
(1)54WT5HOFluorescent*4450lumensperlamp*Testingreadinglamponly.
ReportNo.: ITL60755ModelNo.: ECT5HOEfficiency: 74.8%
LEGEND: 0-deg: 45-deg:
90-deg:
1300
2600
3900
0˚ 15˚ 30˚
45˚
60˚
75˚
90˚
ERAcare™ Candela Distribution
Patient Room View
Horizontal ReadingSurface
6 www.alkco.com
73.986.6
91.3
74.386.9
59.668.8
72.4
59.969.0
43.248.5
50.5
43.448.6
Detail of Angled Reading Surface
Room Parameters
RoomSize: 12’x12’CeilingHt.: 8’-6”
LuminaireMtg.Ht.: 6’AFFRoomReflectances: 80/50/20
Reading Illumination Level (45° Plane, 47” AFF)
Recommended Level* (Avg. Footcandles) 20-50
* RecommendationsarefromANSI/IESNARP-29-06,AnIESNARecommended Practice,LightingforHospitalsandHealthCareFacilities
** Achievedutilizingthereadingopticalcompartmentwith(1)F54T5HOlamp.
Visitwww.alkco.comforcompletePhotometricData
ERAcare™
(Avg. Footcandles) 54**
Patient Room View
A n g l e d R e a d i n g
ERAcare™ Candela Distribution(1)54WT5HOFluorescent*4450lumensperlamp*Testingreadinglamponly.
ReportNo.: ITL60755ModelNo.: ECT5HOEfficiency: 74.8%
LEGEND: 0-deg: 45-deg:
90-deg:
1300
2600
3900
0˚ 15˚ 30˚
45˚
60˚
75˚
90˚
49.96
58.31
53.4152.88
59.0351.25
55.87
53.16
48.54
53.96
7 www.alkco.com
Angled Reading Surface
Luminaire Construction• Theexteriorhousingconsistsofanextrudedaluminumbody anddiecastendcaps.
• Thebackplateandballasttrayareformedfrom18gauge galvanizedsteel.
Finish• ERAcare™canbespecifiedinoneoffourstandard polyesterpowder-coatpaintfinishes–white,taupe, aluminumoralmond.
• Customfinishesareavailableuponrequest.Acolorchip, tomatch,needstobeprovidedbythecustomer.
•Allstandardfinisheshaveanantimicrobialadditivetoinhibit thegrowthofmicrobes.
Reflectors• ERAcare™hasfourseparateanduniquereflectorsroll-formed fromspecularaluminum.
Lens• Thetopambientlens(topsurface)andthefrontexamlensare bothextrudedacrylicwithDRadditiveforflexibilityoverthe lifeoftheproduct.Thebottomexam/readinglensisextruded fromacrylic.
• Internallinearprismshelpmaintainasmoothexteriorsurface.
• Removableextrudedaluminumsocketcoversareprovided attheendsofeachapertureopeningtoconcealthelamp socketandtocreateamoreuniformappearanceacross theilluminatedlenssurface.
Lamps• ERAcare™canbespecifiedwitheitherF54T5HO,F28T5 orF32T8linearfluorescentlamps.
• PhilipsAlto®,lowmercurylampsaresuppliedwiththe luminaire.3500Kisthestandardcolortemperaturebut alternativecolortemperaturescanbespecified.
Switching• Thestandardswitchingconfigurationisanon/offpullcordfor thereadingcompartmentwiththeambientandexamcompart- mentscontrolledfromaremotewallswitch(byothers).
• Anoptional4-positionpullcordswitch(HDS)forsequential controloftheambientandreadingcompartmentsisavailable. Theexamfunctioniscontrolledfromaremotewallswitch.
• Pullswitchesaresuppliedwithaplasticpullcordthatislatex- free,stain-resistant,andeasytocleanwithstandarddisinfectant.
• Anoptionallowvoltagerelay(LVC),thatiscompatiblewith industrystandardbedcontrolsystems(byothers),canbefield wiredforeitherseparateorsequentialswitchingoftheambient andreadingcompartments.
• ERAcare™canalsobespecified“lessswitch”(LS)withremote switching(byothers)controllingallfunctions.
Electrical• Electronichighpowerfactorballasts,ratedfor120and277 volts,areused.347voltballastsavailableforT8lampsonly.
• BallastsarethermallyprotectedandhaveaClass“A”soundrating.
• T5andT5HOballastshaveend-of-lifeprotection.
List ing• ULandCULListed.ERAcare™isalsoIBEWlabeled.
• Agion®antimicrobialhasbeenlistedwiththeU.S.Food andDrugAdministration(FDA),certifiedbytheNational SanitationFoundation(NSF)andregisteredwiththeU.S. EnvironmentalProtectionAgency(EPA).
Instal lation• Thebackplateismountedovertheelectricaljunctionbox ortoelectricalwiringwhipandsecuredtothewallstructure.
• Thehousinghooksontothebackplateandissecuredwith twoscrews.
• Lampreplacementisperformedbyremovingthelensandone socketcover.
Warranty• Limitedlifetimewarrantyonmaterialsandworkmanship. Standardmanufacturerswarrantyappliesonlampsandballasts.
8 www.alkco.com
ECO-FRIENDLY
ECO-FRIENDLY
ECO-FRIENDLY
ECO-FRIENDLY
P ro d u c t S p e c i f i c a t i o n s
ECT5HO
ECT5
ECT8
48-15/16”(1243.1mm)
48-15/16”(1243.1mm)
50-7/8”(1292.22mm)
8-15/16”(227.3mm)
24” (609.6mm)
38” (965.2mm)
16”(406.4mm)
5-1/2”(139.7mm)
5-1/2”(139.7mm)
Side View
Front View
Back View
Cross SectionA. Ambient lamp compartmentB. Reading lamp compartmentC. Exam lamp compartmentD. Rear Exam lamp compartment
ECT5HO (4) F54 T5HO (Med. Bipin)
ECT5 (4) F28 T5 (Med. Bipin)
ECT8 (4) F32 T8 (Med. Bipin)
1202773471
SWH Soft WhiteTPE TaupeAL AluminumALM AlmondCC2 Custom Color
HDS 4-position pull cord switch for sequential control of ambient and reading compartments (120v only)LVC3,4 Low voltage controllerLS Less switchEM13 Emergency ballastNL3 LED night/chart light w/dual 3-position rocker switches (120v and 277v)NL-W3 LED night/chart light (remote switch by others), (120v and 277v) SBF Slow blow fuseBSS3 Bed shut-off switch (120v and 277v)PC Replacement 6’ plastic pull cord (non-latex)
NOM.LENGTH Model Number Voltage Finish
(standard color is SWH)Options
Sample Catalog No: ECT5HO - 277 - SWH - HDS - NL
4’
1 347v available for ECT8 only. 2 Customer to provide color chip to match.3 Not available for 347v applications.4 Not available with EM1 option.
A
BD
C
9 www.alkco.com
D i m e n s i o n a l D a t a
O rd e r i n g I n f o r m a t i o n
Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled “Contains Mercury” and/or with the symbol “Hg”. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org
Hg
Alkco is a Philips group brand
11500 Melrose AvenueFranklin Park, IL 60131Phone (847) 451-0700Fax (847) 451-7512www.alkco.com
© 2008 Philips Group. All rights reserved. Certain products illustrated in this catalog may be protected by applicable patents and patents pending. Alkcowill aggressively defend all of its intellectual property. We reserve the right to change details of design, materials and finishes.
Printed in the U.S.A. 10/08