ali zakeri 15062009 - ntnuena.chemeng.ntnu.no/trondheimjointabsorptionseminar/zakeri... · ali...

27
1 Ali Zakeri Aslak Einbu Lars E. Øi Hallvard F. Svendsen June. 2009 Liquid Hold-up and Pressure Drop in Mellapak 2X

Upload: doantuong

Post on 21-Mar-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

1

Ali ZakeriAslak EinbuLars E. ØiHallvard F. Svendsen

June. 2009

Liquid Hold-up and Pressure Drop in Mellapak 2X

Page 2: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

2

• Packed towers and tower packings have been in use for more than 100 years. Some early examples of their application involve the production of sulfuric acid and the purification of coke oven gas. Prior to 1915, these towers were filled with coke, random-sized and -shaped quartz, broken glass, or broken crockery.

• Tower performance was unpredictable and no two towers would perform alike. The development in 1915 of the Raschig rings made it possible for the first time to impart a degree of predictability and dependability to tower performance.

Packed Columns :

June. 2009

Page 3: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

3

Structured Packing

• The use of structured column packing dates back to the 1960s. The packings are generally manufactured from different materials such as ceramics, metal and plastics and divided according to their shape into: gauze packing, grid type packings, metal sheet and random packings.

• a

June. 2009

Page 4: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

4

Hydrodynamics in packed beds

• The liquid hold up is an important hydrodynamic parameter for gas liquid flow in packed beds. It enables the determination of the pressuredrop and the fluid effective velocity within the packing. The latter is futher used for determination of the liquid side mass transfer cofficient, the liquid hold up is also used to design support devices for the columnsince it gives the liquid weight in operation.

• Pressure drop in packed columns is an important parameter especially in atmospheric and vacuum columns where the separated liquid is sensitive to temperature.

June. 2009

Page 5: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

5

Liquid Hold-up in packed bedThere are two different types of liquid holdup in a packed bed:

• static :Static holdup represents the volume of liquid per

volume of packing that remains in the bed after the gas and liquid flows are stopped and the bed has drained .

• operating :Operating, or dynamic, holdup is the volume of

liquid per volume of packing that drains out of the bed after the gas and liquid flows to the column are stopped .

June. 2009

Page 6: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

6

The static holdup is dependent on :

• the packing surface area

• the roughness of the packing surface

• the contact angle between the packing surface and the liquid

• System properties

Operating holdup primarily is a function of the liquid flow rate and gas/liquid system properties

June. 2009

Page 7: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

7June. 2009

Abso

rber

col

umn

Gas

cha

nnel

The VOCC test rig

Page 8: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

8

The VOCC project

To experimentally characterize various packing materials under varying conditions of gas and liquid flow and chemical system properties

Map the interaction between absorbent and packing properties

To study the effects of exhaust gas with CO2-content between 3-14 vol% on the performance of the absorber

To use the experimental data for validation of in-house software as a basis for absorber and desorber design

Page 9: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

9

5 m packing (different packings will be tested)ID 500 mm columnMax gas velocity 5 m/sLiquid flow up to 10.000 l/h

Pressure and temperature measurement every meter

Section below packing for measuring liquid distribution

Gas

coo

ler

Cyclone

Blower

AB

SOR

BER

2 x 2000 liter amine tanks for batch operation

Setup for liquid hold-up measurements

300 kg CO2 per hour max capacity

CO2-tank

The VOCC test rig

tota

l hei

ght:

18 m

Amine tanks

Well instrumented desorber rig (not shown)for regeneration of rich amine(52 kW electric reboiler)

Page 10: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

10June. 2009

3.0

5.0

7.0

9.0

11.0

13.0

15.0

17.0

19.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Superficial gas velocity (m/s)

Hol

dup

(%)

6.28.610.813.516.820.824.830.737.245.153.564.275.189.1103.7120.7138153.3166.8179.5

Experimental results on relationship between liquid holdup, the phase loads in the packed column

(Air/Water – 1 cP).

Page 11: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

11June. 2009

1.0

3.0

5.0

7.0

9.0

11.0

13.0

15.0

17.0

19.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Superficial gas velocity (m/s)

Hol

dup

(%)

5.36.08.810.813.816,52124.930.837.445.253.764.175.188.5103.1120.1138.7152166.8176

Experimental results on relationship between liquid holdup, the phase loads in the packed column

(Air/Water-Sugar – 3 cP).

Page 12: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

12June. 2009

Experimental results on relationship between liquid holdup, the phase loads in the packed column

(Air/Water-Sugar – 6 cP).

3,0

8,0

13,0

18,0

23,0

0,0 1,0 2,0 3,0 4,0 5,0

Superficial gas velocity (m/s)

Hol

dup

(%)

2.7 m3/m2h

53.6 m3/m2h

31.8 m3/m2h

19.7 m3/m2h

9.4 m3/m2h

Page 13: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

13

Comparison with SULCOLAir- Water 1cP

2.0

7.0

12.0

17.0

22.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Superficial gas velocity (m/s)

Hol

dup

(%)

13.5lit/min 1-cp SULCOL

Air- Water 1-cp

13.5lit/min 1-cp153lit/min 1-cP-SULCOL

153lit/min 1-cP

Page 14: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

14

2.0

7.0

12.0

17.0

22.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Superficial gas velocity (m/s)

Hol

dup

(%)

Air- Water-Sugar 3-cp

153lit/min

153 lit/min SULCOL

13.8 lit/min SULCOL

13.8 lit/min

Comparison with SULCOLAir-Water/Sugar 3cP

Page 15: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

15

3.0

8.0

13.0

18.0

23.0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Superficial gas velocity (m/s)

Hol

dup

(%)

13.4lit/min -6cp SULCOL

13.4lit/min -6cp 166.8 lit/min -6cp SULCOL

166.8 lit/min -6cp

Air- Water-Sugar 6-cp

Comparison with SULCOLAir-Water/Sugar 6cP

Page 16: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

16

DISCUSSIONExperimental curves for the total hold-up hL in a Mellapak 2Xpacking at various air and water loads were measured. Two regions can be distinguished:

• A low gas-load region in which the hold-up hL depends solely on the liquid load, the linear part of the curves.

• A high gas-load region in which hL depends on both the liquid load and the vapor loads, the curvy part of the curves.The transition between these two regions occurs at the loading point.

June. 2009

Page 17: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

17

DISCUSSION

• Hold-up increases with increased viscosity. The influence of viscosity is stronger at high liquid load than at low liquid load. Alix and Raynal(2008) indicate a power law dependency of 0.13 in experiments with Mellapak 252Y. We found a higher dependency at high liquid loadand a lower at low liquid load.

• In the correlations of Rocha et al. (1993), the liquid hold-up is an important parameter in pressure drop estimation. The liquid hold-up and then the pressure drop is expected to increase with increasing liquid viscosity.

• Our experimental hold-up results are significantly higher than what can be predicted from SULCOL. This discrepancy is under investigation

June. 2009

Page 18: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

18

Dry Pressure Drop in M2XDry Pressurer Drop

0

0.5

1

1.5

2

2.5

3

3.5

4

2 2.5 3 3.5 4 4.5 5 5.5 6

Fv (m/s)(kg/m3)^0.5

Pres

sure

Dro

p(m

bar/

m)

June. 2009

The dry pressure drop is measured in packed column in absence of liquid flow. Good agreement between our experimental data and predictions from SULCOL

Calculated from Solcol

ExperimentalData

Page 19: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

19

Pressure Drop throgh M2X

0

5

10

15

20

25

30

35

1 2 3 4 5 6

mba

r

40%

50 %

60 %

70 %

80 %

90 %

100 %

June. 2009

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

40.0

45.0

1 2 3 4 5 6

mba

r

Series21Series2Series3Series4Series5Series6Linear (Series21)Linear (Series4)Linear (Series5)Linear (Series6)

Pressure drop was measured based on pressure measurement at 6 positions along the packing height. The liquid flow rate was between 0 and 55 m3/(m2·h), and gas flow was between 0 and 17000 m3/(m2·h). The pressure profiles through the packing were close to linear.

Page 20: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

20

Pressure Drop in M2XWater/Air-1cP

June. 2009

0.1

1

10

100

0 1 2 3 4 5 6

Fv(m/s)(Kg/m3)^0.5

Pres

sure

Dro

p(m

bar/m

)

6.28.613.520.830.745.164.289.1120.7153.3179.5

Page 21: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

21

Pressure Drop in M2XWater/Air-Sugar-3cP

June. 2009

0.1

1

10

100

0 1 2 3 4 5 6

Fv (m/s)(Kg/m3)^.5

Pres

sure

Dro

p(m

bar/m

)

6.08.810.813.816,52124.930.837.445.253.764.175.188.5103.1120.1138.7152166.8176

Page 22: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

22

Pressure Drop in M2XWater/Air-Sugar-6cP

June. 2009

0.1

1

10

100

0 1 2 3 4 5 6

Fv (m/s)(Kg/m3)^0.5

Pres

sure

Dro

p(m

bar/m

)

5.38.810.813.416,320.924.730.637.245.453.464.375.288.5103.9120.8138.4152166.8176

53.6 m3/m2h31.8 m3/m2h

2.7 m3/m2h

13.9 m3/m2h

Page 23: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

23

Air Water- 1 cP

0.1

1

10

100

0 1 2 3 4 5 6

Fv(m/s)(Kg/m3)^0.5

Pres

sure

Dro

p(m

bar/m

)

153lit/min1-cP

153lit/min1-Cp SuLCOL

Air- Water 1-cp

13.5lit/min1-cP SULCOL

13.5lit/min1-cP

Page 24: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

24

Air- Water-Sugar 3-cP

0.1

1

10

100

0 1 2 3 4 5 6

Fv (m/s)(Kg/m3)^.5

Pres

sure

Dro

p(m

bar/m

)

Air- Water-Sugar 3-cp

13.8lit/min - 3cp-SULCOL

13.8lit/min 3cp

166.8 lit/min- 3 cp SULCOL

166.8 lit/min- 3 cp

Page 25: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

25

Air-Water- Sugar 6 cP

0.1

1

10

100

0 1 2 3 4 5 6

Fv (m/s)(Kg/m3)^0.5

Pres

sure

Dro

p(m

bar/m

)

13.4 lit/min 6 cp

13.4 lit/min 6 cp SULCOL

152 lit/min 6 cp

13.4 lit/min 6 cp SULCOL

Air- Water-Sugar 6-cp

Page 26: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

26

DISCUSSION

• The pressure drop values in the figures are based on the pressure instruments just below and just above the packing. The total pressure drop followed the expected pattern as a function of liquid and gas flows.

• The column showed flooding-like behaviour at superficial gas velocities of about 3 - 4 m/s depending on the liquid flow. (The flow factor is about 1.1 times the gas velocity at the given conditions.)

• The pressure drop increases slightly with increased viscosity. According to traditional flooding and pressure drop charts (Strigle, 1993), the pressure drop dependence on liquid viscosity can be seen from the capacity factor, which is proportional to the gas flow in exponent 2 and the liquid viscosity in exponent 0.1 (assuming constant liquid density).

June. 2009

Page 27: Ali Zakeri 15062009 - NTNUena.chemeng.ntnu.no/TrondheimJointAbsorptionSeminar/Zakeri... · Ali Zakeri Aslak Einbu ... random-sized and -shaped quartz, broken glass, ... volume of

27

Thank you