Albion Devices,Inc (858-792-9585) has a long and proud record of doing business with the Railroad industry. In this brief presentation, you will learn how our leadership in temperature compensation can assist you in precision dimensional measurements of railroad wheel sets. Subscribe for more information at www.TemperatureCompensation.comTRANSCRIPT
![Page 1: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/1.jpg)
Temperature CompensationTemperature Compensationand railroad wheelset precision and railroad wheelset precision dimensional measurementsdimensional measurements
by Albion Devices, Incby Albion Devices, Inc
This is a MS Powerpoint presentation. Please use mouse clicks, space bar or arrow keys to move between slides.
![Page 2: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/2.jpg)
Albion - the leader in temp comp• Railroad wheelsets include
some components that have tight tolerances. For example, the AAR requires that axle journals and bearing races (cones) are finished to dimensions measured in tenths of thousands of an inch.
• It can be hard to hold these tolerances consistently in changing temperatures.
This is a MS Powerpoint presentation. Please use mouse clicks, space bar or arrow keys to move between slides.
![Page 3: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/3.jpg)
Albion - the leader in temp comp
• Most railcar axle journals and bearings are approximately 5 to 7 inches in diameter.
• Over a temperature range of 40ºF to 140ºF (4ºC to 60ºC)
their diameters will change by .0050 to .0070 inch (0.13mm to 0.18mm).
This is a MS Powerpoint presentation. Please use mouse clicks, space bar or arrow keys to move between slides.
![Page 4: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/4.jpg)
Albion - the leader in temp comp• Maximum tolerance is usually no more than
+/- .0005 inch (+/- 0.013mm).• Albion’s gages repeatably correct all measurements
to the International Reference Temperature of 68ºF (20ºC) to within +/- .0002 inch (+/- 0.005mm) over a temperature range of 40ºF to 140ºF (4ºC to 60ºC)
This is a MS Powerpoint presentation. Please use mouse clicks, space bar or arrow keys to move between slides.
![Page 5: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/5.jpg)
Albion - the leader in temp comp
• All metals expand and contract as temperatures vary. By eliminating these effects from precision measurements, our gages provide repeatable and reproducible measurements year round in all climates and working conditions.
This is a MS Powerpoint presentation. Please use mouse clicks, space bar or arrow keys to move between slides.
• Albion Devices, Inc., is the world leader in temperature compensation of precision dimensional measurements.
![Page 6: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/6.jpg)
An Introduction to TComp
This is a MS Powerpoint presentation. Please use mouse clicks, space bar or arrow keys to move between slides.
• Albion Devices, Inc., developed TComp (“tee-comp”) temperature compensated snap gages and bearing cone gages specifically for the railroad industry and in consultation with key AAR officals. The unique, built-in temperature compensation capabilities of these units make them the most consistently accurate shop floor snap gages and bearing gages available.
![Page 7: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/7.jpg)
TComp digital indicator.
• The TComp digital indicator lies at the heart of our railroad gages. It is a small, battery or mains powered, micoprocessor-based system that is designed to fit on a custom snap gage frame or other gage fixture so as to take temperature compensated comparative measurements.
![Page 8: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/8.jpg)
• Mounted on a manually operated snap gage, TComp can produce accurate and repeatable measurements to within + / - .0002 inch (5 microns) or better, over a temperature range of 40ºF to 140ºF (5ºC to 60ºC).
Snap Gage configuration
![Page 9: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/9.jpg)
Stack gage
• Dual TComps can be mounted into a specially designed bearing cup gage, called a “stack gage”, used extensively in the railroad industry.
![Page 10: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/10.jpg)
Fixture mounted applications• Mounted in a fixture or a
stand, TComp is capable of accurate and repeatable measurements to within + / - .0001 inch (2.5 microns) or better, over a temperature range of 40ºF to 140ºF (5ºC to 60ºC) on the shop floor.
• Tcomp can also be mounted on a bar gage for critical large diameters.
![Page 11: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/11.jpg)
Tcomp’s transducers• TComp indicator is equipped
with a transducer assembly that contains 3 sensors: an LVDT, a workpiece/master temperature sensor (that senses through the carbide face of the measuring anvil) and a gage fixture temperature sensor (that monitors the temperature of the frame or fixture in which it is mounted).
Workpiece sensor
LVDT
Gage sensor
![Page 12: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/12.jpg)
Controls
• TComp is programmed and operated through a simple touch pad on the front panel.
• An LCD displays data and measurements.
![Page 13: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/13.jpg)
Transducers
• LVDT probe and temperature sensors are mounted within the gage fixture so as to make suitable contact with respective components.
• The “Gage” sensor monitors the temperature of the snap gage frame. The “Workpiece” sensor senses the temperature of the workpiece and the master.
![Page 14: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/14.jpg)
Operation• In operation, TComp notes the
temperature of the master during the mastering (zeroing) cycle, then switches automatically into Measure Mode. In this mode it assumes that it is measuring a workpiece and applies the respective correction coefficient. Meanwhile, the gage sensor applies yet another coefficient to any changes in gage fixture or frame temperature.
![Page 15: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/15.jpg)
Compensation Algorithm• TComp’s programmed
algorithm takes into account any variation in the temperatures of the workpiece, master or gage fixture (the “elements” of the measurement system) from Nominal Temperature (usually 68°F/20°C).
WorkpieceTemperature
MasterTemperature
GageTemperature
WorkpieceCoefficient
MasterCoefficient
GageCoefficient
CompensationAlgorithm
TemperatureCorrectedDimension
![Page 16: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/16.jpg)
Algorithm (cont)• TComp applies these variations to user-programmable
correction coefficients (expansion coefficients) and to the user programmable nominal dimension (since coefficients are expressed in terms of size variation (inch or MM) per degree of temperature (°F or °C) per unit of dimension (inch or MM)).
![Page 17: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/17.jpg)
Correction to 68°F/20°C
• The net size variation after allowing for expansion or contraction in all 3 elements is applied in real time to dimensional measurements made by TComp’s LVDT.
• The result is that all displayed dimensions show the size that the workpiece would measure if it, the master and the gage frame were all at Nominal Temperature (68°F/20°C).
![Page 18: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/18.jpg)
Temperature sensing
• The key to the success of TComp’s system is in accurate and rapid temperature sensing.
• This is accomplished by using stable and accurate electronic chip and thermistor technology housed in protective housings within the gage.
![Page 19: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/19.jpg)
The Dramatic Potential
Temperature Compensation of precision gaging provides dramatic improvement in:
• Process control• Gage repeatability• Gage correlation• Scrap and rework reduction• Overall quality control
![Page 20: Albion Devices Railroad Products](https://reader035.vdocuments.mx/reader035/viewer/2022081508/557d3d4bd8b42ac2788b5017/html5/thumbnails/20.jpg)
Product Range
• The remarkable thermal correction capabilities of TComp can be applied to a wide range of gages. Be sure to ask us about our other temperature compensated gages and systems.