alarma gem p3200

76
R PROGRAMMING INSTRUCTIONS HARDWIRE WIRELESS GEM-P3200 CONTROL PANEL/COMMUNICATOR WI818D 8/00 ' Napco 2000 Quick Start: 1. Refer to the wiring diagram, connect the keypad(s), siren, aux. power, aux. output, remote bus, earth ground, zone and telephone wiring. NOTE: See Installation Instructions (WI817). 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 63). 4. Access the Easy Menu Driven (Dealer Program) Mode: Press EEEEEE A Press g Until ACTIVATE PROGRAM Y/N (GEM-RP1CAe2), TURNON PROG Y/N (GEM-RP2ASe2) or 17 (GEM-RP3DGTL) appears on the keypad display. Press F To Enter Dealer Program Mode (see page 6). Master Security Code (on microshield) R COMPUTERIZED SECURITY SYSTEM ARMED STATUS SYSTEM ARMED 12 4 3 56 7890 A B C D E F G NEXT/YES PRIOR/NO AREA GEMINI 48 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME GEM-RP2ASe2 R COMPUTERIZED SECURITY SYSTEM ARMED STATUS SYSTEM ARMED 12 4 3 56 7890 A B C D E F G NEXT/YES PRIOR/NO AREA GEMINI AC ON READY AC ON GEM-RP1CAe2 R COMPUTERIZED SECURITY SYSTEM GEMINI ARMED STATUS 12 4 3 56 7890 A B C D E F G NEXT/YES PRIOR/NO AREA SYSTEM ARMED 01/01/00 12:00 AM GEM-RP3DGTL

Upload: carferna

Post on 14-Oct-2014

122 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Alarma GEM P3200

R

PROGRAMMINGINSTRUCTIONS

HARDWIRE WIRELESS

G E M - P 3 2 0 0CONTROL PANEL/COMMUNICATOR

WI818D 8/00© Napco 2000

Quick Start:1. Refer to the wiring diagram, connect the keypad(s), siren, aux. power, aux. output, remote bus, earth ground, zone and telephone

wiring. NOTE: See Installation Instructions (WI817).

2. Connect AC power first and then the battery.

3. Configure the keypad (see page 63).

4. Access the Easy Menu Driven (Dealer Program) Mode:

Press EEEEEE A

Press g Until �ACTIVATE PROGRAM Y/N� (GEM-RP1CAe2), �TURNON PROG Y/N� (GEM-RP2ASe2) or �17� (GEM-RP3DGTL) appears on the keypad display.

Press F To Enter Dealer Program Mode (see page 6).

Master Security Code(on microshield)

R

COMPUTERIZED SECURITY SYSTEM

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

GEMINI

ENT A148INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

GEM-RP2ASe2

R

COMPUTERIZED SECURITY SYSTEM

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

GEMINI

READYAC ONREADYAC ON

GEM-RP1CAe2

R

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

SYSTEM ARMED01/01/00 12:00 AM

GEM-RP3DGTL

Page 2: Alarma GEM P3200

CHANGES FROM PREVIOUS EDITIONThe following changes have been made to this manual (WI818D) since the last edition (WI818C).

New GEM-P3200 Version 20 Features: ! New Easy Menu Programming allows the system to be completely programmed through Menu Driven Easy

Program Mode. Requires the use of the following version keypads:• GEM-RP1CAe2, Version 6• GEM-RP2ASe2, Version 5b• GEM-RP3DGTL, Version 1c

! Maximum Wireless Zones expanded from 32 to 48! Maximum Number of Users expanded from 32 to 48! Chime 2 zone provides second distinct pulsating �Chime Zone� tone! Set System Time and Date in User Program Mode! System Trouble Audible Automatic Timeout! Inhibit System Trouble Audible! Easy Programming of PC Preset Auto download ID and Callback Numbers! Support of GEM-PRINT module! Cancel Reporting Code! Wireless Trouble Reporting by Zone! Pager (Telco 3) Reporting Delay! Pager - Programmable Number of Reports of Same Signal! Pager - Maximum Number of Consecutive Pages! Specific Logging of Communication Failure Modes! New Relay Event �Area Disarmed� (PCD3000 programmable only)! Programmable DST start date (PCD3000 programmable only)! 20 Digit Dialing Prefix

NOTE: Typically, any version GEM-P3200 control panel could be upgraded to the latest firmware by replacing theEPROM with a newer version. This is no longer the case. The Firmware Version 20 EPROM must only be used in aVersion 18 (or greater) PCBoard. Do NOT attempt to upgrade a GEM-P3200 control panel which currently is runningFirmware Version 11C (or prior) to version 20 (or greater) by replacing the EPROM.

The PCBoard version ( triangle number) is printed on a triangular shaped sticker affixed to the GEM-P3200 circuit board.

THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANELFIRMWARE VERSION 20 OR LATER.

NAPCO Security Systems, Inc.333 Bayview Avenue, Amityville, New York 11701

For Sales and Repairs, call toll free: (800) 645-9445For direct line to Technical Service, call toll free: (800) 645-9440

Internet: http://www.napcosecurity.com

Upon entering program mode, the keypad display will flash the control panelfirmware version, followed by the keypad firmware version:GEM-RP1CAe2: [2006], GEM-RP2ASe2: [205b], GEM-RP3DGTL: [20/1C]

Page 3: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 3

SYSTEM PROGRAMMING OPTIONS.............................4Introduction ..................................................................4Downloading from a Computer ....................................4

EASY MENU DRIVEN PROGRAM MODE.......................5Dealer Program - Preliminary Information ...................5Accessing Dealer Program Mode ................................5Customizing a Default Program...................................5GEM-RP1CAe2 KEYPAD............................................6

Number of Zones & Keypads per Area...................6Local or Central Station Reporting System.............6Central Station Receiver 1 Tel. Number .................7Central Station Receiver 1 Account Number ..........7Central Station Receiver 1 Format .........................8Enter User Codes ...................................................9RF Transmitter Points.............................................11Key Fob Transmitters .............................................12Enter Zone Descriptions .........................................12Enter Date...............................................................12Enter Time .............................................................13Enter Dealer Code ..................................................13Clear Dealer Program.............................................13

GEM-RP2ASe2 KEYPAD ............................................14Number of Zones & Keypads per Area ..................14Local or Central Station Reporting System.............15Central Station Receiver 1 Tel. Number .................16Central Station Receiver 1 Account Number ..........16Central Station Receiver 1 Format .........................16Enter User Codes ...................................................17RF Transmitter Points.............................................19Key Fob Transmitters .............................................20Enter Date...............................................................21Enter Time ..............................................................21Enter Dealer Code ..................................................21Enter Dealer Program.............................................21

GEM-RP3DGTL KEYPAD ..........................................22DIRECT ADDRESS PROGRAM MODE...........................29

Keypad Programming Overview ..................................29Accessing Direct Address Program Mode ...................29What You See on the Keypad......................................30Direct Address Program Mode Keypad Commands ....30Programming Overview ...............................................32

Direct Address Programming Example...................33

PROGRAMMING OPTIONS & WORKSHEETS.............. 34System Delays (Addr 0000-0002, 2402, 2406 & 2414)..................................................................................... 35System Delays (Addr 2407, 2408 & 4088) .................. 35System Delays (Addr 2400, 2401, 2403-2405 & 4083)..................................................................................... 36Keypad System Codes (Addr 0490, 0495 & 0500)...... 36CS Receiver Opt. (Addr 0520, 0521, 0525, 0526, 0550,0551, 0575 & 0576) ..................................................... 37CS Receiver Tel. Numbers (Addr 0527-0546, 0552-0571,0577-0596) .................................................................. 38Download/Callback Options (Addr 4089, 0600-0619,0625-0647, 1022 & 1023)............................................ 38CS Subscriber ID Numbers (Addr 0650-0857) ............ 39CS Reporting Codes (Addr 0860-0869) ...................... 40CS Reporting Codes (Addr 0870-0904) ...................... 41CS Area & System Reporting Opt. (Addr 1024-1027) . 41CS Zone Reporting Codes (Addr 0910-0957) ............. 42CS User Reporting Codes (Addr 1030-1081).............. 43Global System Trbl. Reporting Opt. (Addr 1082-1116)45Area System Trbl. Reporting Opt. (Addr 1120-1137) .. 46Zones 1-48 Options (Addr 1200-1786)........................ 47System Options (Addr 2415-2419) .............................. 51System Options (Addr 2420-2422 & 4084).................. 52Keypad Options (Addr 2425-2454).............................. 54User Area Options (Addr 2500-2547).......................... 55EZM Group Options (Addr 2600-2627) ....................... 56Area Arming Options (Addr 2650-2651) ...................... 57Remote Access Logging (Addr 3184).......................... 57Area Output Control Options (Addr 2700-2733) .......... 58RF Rcvrs. & Sup. Timers (Addr 3776 & 3760-3775) ... 59System Reset Features (Addr 4091-4093).................. 60

USER PROGRAM MODE ................................................ 61Preliminary Information................................................ 61Accessing User Program Mode................................... 61User Codes.................................................................. 61Zone Descriptions........................................................ 62

KEYPAD CONFIGURATION MODE................................ 63Keypad Installation ...................................................... 63Configuring the Keypads ............................................. 63

KEYPAD PROGRAMMING MODES ............................... 66PROGRAMMING OPTIONS INDEX ................................ 71GEM-P3200 WIRING DIAGRAM ..................................... 75

TABLE OF CONTENTS

Refer to accompanying GEM-P3200 Installation Instructions (WI817) for installation information.

NOTE: THESE INSTRUCTIONS ARE INTENDED AND WRITTEN FOR PROFESSIONAL INSTALLATION PERSONNEL HAVING SUITABLETRAINING, EXPERIENCE AND INSTALLATION EQUIPMENT. IT IS RECOMMENDED THAT AFTER PROGRAMMING, THE ERROR CHECKUTILITY OF THE PCD3000 DOWNLOADER BE USED TO VERIFY THAT THE CONTROL PANEL PROGRAM CONTAINS NO ERRORS OR

CONFLICTS WHICH MAY INHIBIT ITS INTENDED OPERATION.

Page 4: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 4

SYSTEM PROGRAMMING OPTIONS

INTRODUCTIONThe GEM-P3200 control panel may be programmed by various means, each of which will be covered in detail in thesections that follow. Keypad displays shown first are for a GEM-RP1CAe2 (Version 6), the recommended keypad forprogramming, then for the GEM-RP2ASe2. The GEM-RP2ASe2 keypad functions similarly; however, because of itsreduced display capabilities, messages are abbreviated and will scroll through two or more screens. Zone descriptionscannot be programmed using a GEM-RP2ASe2 keypad.

! Downloading From a Computer. This is the preferred method. The panel may be downloaded from (or uploadedto) an IBM PC-compatible computer, with a 386 (or higher) microprocessor, either locally or remotely. NAPCO'sPCD3000 Quickloader software, Version Update 3.34 or later features context-sensitive help screens as well as anerror-checking utility that prevents programming of incompatible or conflicting data to ensure proper panel operation.! Easy Menu Driven Program (Dealer Program) Mode - Keypad Programming. The Easy Menu Driven ProgramMode allows keypad programming of number of zones in area 1, number of zones in area 2, fire zone numbers (both4-wire and 2-wire), central station reporting, entry/exit zone numbers, interior zone numbers, number of keypads inarea 1, number of keypads in area 2, central station telephone number, central station account number, auto downloadid number & PC preset callback telephone number, central station receiver format, user codes, RF transmitter points,RF key fob transmitters,zone descriptions,date and time. For new panels, a custom default program may be createdat the keypad. A menu-driven utility prompts the installer to configure the system. Further detailed customization isdone in the Direct Address Program Mode.! Direct Address (Dealer Program) Program Mode - Keypad Programming. The Direct Address Program Modeis an extension of the Dealer Program Mode wherein data is entered at the keypad by location. This mode is accessedfrom the Easy Menu Driven Program Mode by pressing the C button at any time.

! User Program Mode - Keypad programming. The User Program Mode is intended for authorized users and islimited to keypad programming of User Codes, Zone Descriptions, Time and Date.

DOWNLOADING FROM A COMPUTERThe control-panel program may be downloaded from thecomputer by either of the following methods.

Local Downloading(Note: This procedure should be used after installation, after peripheral devices are connected.)For a direct high-speed data transfer to the control panel from a desktop computer, connect the download jack (J1) on thepanel to the LOCAL jack (J3) on the Napco PCI2000/3000 computer interface using the supplied 6-conductor cable.(Refer to PCI2000/3000 Installation Instructions WI443 for wiring diagram and procedures.)Similarly, a high-speed local download may be made in the field using a notebook or laptop computer. Connect J1 on thecontrol panel to a Napco PCI-MINI computer interface using the 6-conductor cable supplied. (Refer to PCI-MINIInstallation Instructions WI767.)

Remote Downloading(Also see PCI2000/3000 Installation Instructions WI443.)

Function Mode. During this procedure, voice contact will be lost, therefore both the installer and the computer operatorshould be familiar with the operation. When a steady high-pitched tone is heard at the site phone, access the �ACTIVATE

DOWNLOAD� Function (see Keypad Programming Modes), then press the J button or the YES (E) button; the sitephone will go dead. Hang up the phone and wait for a call from the central station confirming a successful download.

Callback Method. An installed, unattended panel may be programmed or reprogrammed remotely using the Callback-Method Download feature of the PCD3000 software. Remote downloading requires a modem compatible with thePCI2000/3000. Upon answering the call from the computer, the panel will verify the Download Security Code and, ifconfirmed, will establish a connection. If a Callback Number is programmed into the panel, the panel will automaticallydisconnect and call the computer at this number before establishing a connection. The panel can support two CallbackNumbers to allow downloads from two different offices.

Page 5: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 5

EASY MENU DRIVEN PROGRAM MODE

DEALER PROGRAM - PRELIMINARY INFORMATION! Only Keypad #1 may be used for both dealer and user programming, however this keypad may be located in any

area.! The Master Security Code is printed on the panel�s microprocessor can. Use this code to enter the Dealer Program

Mode to program a custom Dealer Security Code. Record the number, then remove the code label to prevent unauthorized access to the panel. If you forget your Dealer Security Code, use the Master Security Code to enter programming.

! After entering codes or data, press the save Jbutton. Data will not be stored into memory unless it is pressed.

! If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound. Silence the sounder by pressing the G button to continue, or by pressing the C button to exit.

! A panel that has been COLD STARTED (Address Location 4093) performs identically to a new panel.! When programming more than 2 areas, Direct Address Programming Mode must be used to complete the program.

If a GEM-RP2ASe2 (Version 5b) is used, configure address jumpers as Keypad #1 (see Configuring the GEM-RP2ASe2Keypad.).

ACCESSING DEALER PROGRAM MODE

CUSTOMIZING A DEFAULT PROGRAMFor any new panel, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:

This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has been loaded, youmay alter it as necessary in the Direct Address Program Mode.

KEYPAD #1: For ease of programming, it is recommended that a GEM-RP1CAe2 (Version 6) be used as Keypad #1.(Regardless of which keypad is selected, all new keypads are configured as Keypad #1 out of the box.)

NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by anymeans, the number of areas, number of zones, fire zones, entry/exit zones and interior zones will be suppressed and cannot bechanged. Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the C buttonto enter the Direct Address Program Mode; (b) access Location 4091 (Clear Program); (c) press the J button and start over.

Accessing D

ealer Program M

ode

1. Press EEEEEE A

2. Press g Until �ACTIVATE PROGRAM Y/N� (GEM-RP1CAe2),�TURNON PROG Y/N� (GEM-RP2ASe2) or �17� (GEM-RP3DGTL) appears on the keypad display.

3. Press F To Enter Dealer Program Mode.

4. Press CC To Exit Dealer Program Mode when finished.

Master Security Code(on microshield)

R

GEM-P3200CONTROL

COMMUNCIATOR

MASTER SECURITY CODE# - # - # - # - # - #

GEM-P3200

R

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

# OF ZONES IN AREA 1ENTER # ZONES X XAI #ZN=08 #KP=1����������������A2 #ZN=00 #KP=0

! Number of Zones in Area 1! Number of Zones in Area 2! Fire Zones! 2-Wire Fire Zones! Local System or Central Station Reporting! Exit/Entry Zones! Interior Zones! Number of Keypads in Area 1

! Number of Keypads in Area 2! CS Receiver 1 Telephone Number! Auto Download ID Number & PC Preset

Callback Telephone Number! CS Receiver 1 Account Number! CS Receiver 1 Format! User Codes! RF Transmitter Points

! Key Fob Transmitters! Zone Descriptions *! Date *! Time *! Dealer Code* NOTE: GEM-RP1CAe2 Keypad Only

Page 6: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 6G

EM-R

P1C

Ae2

Key

pad:

Zon

es p

er A

rea,

Fire

Zon

es, 2

-Wire

Fire

Zon

es &

CS

Rep

ortin

gA. GEM-RP1CAe2 Keypad

To create your customized default program using a GEM-RP1CAe2 keypad, enter the followingparameters. In each of the following steps, press the A button to set cursor, the NEXT (E)button to go forwards, the PRIOR (F) button to go backwards, the Jbutton to save and the Cbutton twice to exit at any time.

Total Number of Zones in Area 1 & Area 2 (Appears for New Panel Only)Directly enter the total number of zones to be programmed for Area 1 andArea 2, respectively. Valid entries are from 01 to 48. Directly enter the totalnumber of zones, including leading zeros. Use number buttons 1through 9. NOTE: Press the 0 button for a zero. The system isbased on groups of 4 zones each (after the first 8 zones), and willautomatically round up to the next group of 4. For example, if you enter 18,it will automatically convert this to 20 zones. Press Jto save. Press NEXT(E) button to proceed.

Note: The GEM-P3200 is limited to a combined maximum of 48 zones and 7 keypads. All 48 zones and 7 keypads maybe programmed in the EZ Program Mode. For more options, see Zone and Keypad Options in Direct AddressProgramming.

Fire Zones (Appears for New Panel Only)Enter the zone number of any Fire Zones (both 2-wire, 4-wire or wireless).Valid entries are from 01 to 48. Directly enter each zone number, includingleading zeros, and press Jto save, and then repeat for any additionalzone(s). Press NEXT (E) button to proceed.

NOTE: If you are programming a 2 Area system, enter the zone number of zones required for Areas 1 & 2. All fire zonesare common to areas 1 and 2. The Direct Address Program Mode can then be used to customize them as needed. SeeZone Options.

2-Wire Fire Zones (Appears for New Panel Only)Enter the zone number of any Fire Zones (from previous question) whichare to be used with 2-wire smoke detectors. The only valid entries are 07and 08 Directly enter each zone number, including leading zeros. Press Jtosave, and then repeat for any additional zone(s). NOTE: Only zones which

have been designated as Fire Zones can be programmed as 2 Wire Fire zones. Press NEXT (E) button to proceed.NOTE: JP7 must be set to �2-WF� position for 2-wire fire zones 7 and 8 (refer to Installation Instructions).

Local System or C.S. Reporting System (Appears for New Panel Only)Press YES (E) button for all zones to report; press NO (F) buttonfor no zones to report (LOCAL SYSTEM).

R

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

# OF ZONES IN AREA 1ENTER # ZONES X XAI #ZN=08 #KP=1�����������������

A2 #ZN=00 #KP=0

(Direct Entry)

#OF ZNS IN AREA1ENTER # ZONES 08

(Direct Entry)

#OF ZNS IN AREA2ENTER # ZONES 00

(Direct Entry)

F I R E Z O N E SENTER ZONE # 00

(Direct Entry)

2 - W I R E F I R E Z N SE N T E R Z O N E # 0 0

(Press YES or NO)

REPORT ALL ZONESTO CENTRAL? Y/N

Page 7: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 7Exit/Entry Zones (Appears for New Panel Only)Directly enter the zone numbers which are to be used as Exit/Entry zones.Valid entries are from 01 to 48. Directly enter each zone number, includingleading zeros. Use number buttons 1 through 9. NOTE: Press the0 button for a zero. Press Jto save and then repeat for any additionalzone(s). Press NEXT (E) button to proceed.

NOTE: Exit/Entry Zones will have an entry delay of 30 seconds and an exit delay of 60 seconds. Chime will automaticallybe programmed for all E/E zones. If you are programming a 2 Area system, enter all of the zones required for Areas 1 & 2.

Interior Zones (Appears for New Panel Only)Directly enter the zone numbers which are to be used as Interior Zones. Validentries are from 01 to 48. Directly enter each zone number, including leadingzeros. Use number buttons 1 through 9. NOTE: Press the 0button for a zero. Press Jto save and then repeat for any additional zone(s).Press NEXT (E) button to proceed.

NOTE: All Interior zones will also be automatically programmed as �Exit/Entry Follower� zones. If you are programming a2 Area system, enter all the zones required for Areas 1 & 2.

Number of Keypads in Area 1Directly enter the total number of Keypads to be installed in Area 1. Validentries are from 01 to 07. Directly enter the number of keypads, includingleading zeros. Use number buttons 1 through 9. NOTE: Press the0 button for a zero. Press Jto save. Press NEXT (E) to proceed.

Number of Keypads in Area 2Directly enter the total number of Keypads to be installed in Area 2. Validentries are from 01 to 07.

Central Station Receiver 1 Telephone NumberUsing number buttons, enter telephone number of up to 16 digits includingprefix letters, if necessary, for receiver 1. Use number buttons 1 through9 for digits 1�9; press the G 0 button for a zero and G1 through G 5 for letters B�F, respectively. NOTE: Pre-Dial

Delay = �D�; Dial-Tone Detection = �E�. Pressing the 0 button will produce a blank space (�). Press Jto save. PressNEXT (E) button to proceed. NOTE: Central Station Receiver 2 and 3 Telephone Numbers can only be entered inDirect Address Programming. See CS Receiver Options.

(Direct Entry)

EXIT/ENTRY ZONESENTER ZONE # 00

(Direct Entry)

INTERIOR ZONESENTER ZONE # 00

(Direct Entry)

# A R E A 1 KE Y P A D SE N T E R # K P S 0 1

(Direct Entry)

# A R E A 2 K E Y P A D SE N T E R # K P S 0 0

(Direct Entry)

CENTRAL PHONE #_ _ _ _ _ _ _ _ _ _ _ _ _

GEM

-RP1C

Ae2 K

eypad: Exit/Entry Zones, Interior Zones, Keypads per A

rea, CS Tel. N

o. & C

S Acct. N

o.

Easy Programming of Auto download ID #'s and PC Preset Callback Numbers (GEM-RP1CAe2 only)For unattended PC Preset downloading, it is now possible to set the Auto download ID #�s and PC Preset Callback fromthe Keypad Easy Program Mode.• At the field for CENTRAL PHONE #, program an "F" followed by the Auto Download ID # (2 digits) and then the

Callback Telco # (up to 13 digits).• Press [ON/OFF] to save.• Exit Program Mode ([RESET] [RESET]).• Enter Master Code• Press [FUNCTION]• Go to Function "ACTIVATE DOWNLOAD Y/N" and press YES (INTERIOR).• The panel will automatically call the PC Preset computer and download the program on the specified Auto

Download line # of PC Preset.Example: Program an Auto download ID # of 07 and a PC Preset Callback #of 1-516-842-9400

• Go to Central Phone # input screen and press: [*] [5] [0] [7] [1] [5] [1] [6] [8] [4] [2] [9] [4] [0] [0] [ON/OFF]

CENTRAL PHONE #F 0 7 1 5 1 6 8 4 2 9 4 0 0

Page 8: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 8

Central Station Receiver 1 Account NumberEnter an account number of up to four digits. Use number buttons 1through 9 for digits 1�9. NOTE: Press the 0 button for a zero andpress the G 0 buttons for a blank space (�).G 1 throughG 5 for letters B�F, respectively. Press Jto save . Press NEXT(E) button to proceed.NOTE: Central Station Receiver 2 and 3 Account Numbers can only beentered in Direct Address Programming. See CS Reporting Options.

Central Station Receiver 1 FormatFrom the table below, enter the central station's receiver format. Usenumber buttons 1 through 9. NOTE: Press the 0 button fora zero. and press the G 0 buttons for a blank space (�). PressG 1 through G 4 for letters B�E, respectively.Press Jto save. Press NEXT (E) button to proceed.

DATAENTRY

CS RECEIVER 1 FORMAT

blank(�) Ademco Slow, Silent Knight Slow1 Sescoa, Vertex, DCI, Franklin

Fast2 Radionics Fast3 Silent Knight Fast4 Radionics, DCI, Franklin Slow5 Universal High Speed8 Radionics BFSK

DATAENTRY

CS RECEIVER 1 FORMAT

9 FBI 4/3/10 Radionics Modem 2B SIAC Ademco Point IDD Ademco ExpressE Pager

NOTE: Modem IIe is available only in DirectAddress Programming. Central StationReceiver 2 and 3 Formats can only be enteredin Direct Address Programming. See CSReceiver Options.

(Direct Entry)

SEE WI FOR INFORCVR FORMAT (0)

GEM

-RP1

CA

e2 K

eypa

d: C

S Fo

rmat

(Direct Entry)

CENTRAL STATIONACCOUNT #(____ )

Page 9: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 9G

EM-R

P1CA

e2 Keypad: U

ser Codes

Enter User Codes (Press the (A) button to set cursor.)Enter up to 48 User Codes with User Options, Authority Level and AccessControl Options (if necessary) for each code. Refer to the tables below andon the next page for available data entries for User Options, Authority Leveland Access Control Options. Note: All 48 Users must be assigned to areasin �Enable User Code by Area� (Address 2500-2547) in Direct AddressProgramming. By default, only User 1 is enabled in Area 1 and Area 2.

User 2 - 8 are enabled in Area 1 and user 9 - 16 are enabled in Area 2.! Press the (A) button to set the cursor to the User Code. Use the number buttons 1 through 9 to

enter a code of up to 6 digits. Enter up to 6 digits (4 digits is recommended) in the first six boxes from left to right for each user code. Valid entries are: 0-9. Note: Press the 0 button for a zero. No blank spaces in between; leave blank (�) any trailing boxes. If an �Ambush Code� (Address 0495) is entered, do not program the first two digits of ANY User Code as the same digits entered for the �Ambush Code�.

! If the programmed code is less than 6 digits, press the A button to set the cursor to the OPTION/LEVEL. Refer to the tables below for the available User Option and User Level data entries. Enter the user options data in the left digit. Enter the level data (with arming options, if any, added) in the right digit. Note: For entries greater than 9, press the G1 buttons through the G5 buttons for B through F, respectively.

! For Keypad Access Control, press the A button once again to program applicable keypads. Refer to the tables below, use the number buttons to enter the data for Keypad 1�4 in the right digit; and the data for Keypad 5�7 data in the left digit. (Press the 0 buttons for blank.)

User# User Code Option Access

/Level Control

ENTER USER CODEU01 123___ -F3 -__

USER OPTIONSUSER CODE

(UP TO 6 DIGITS)USER

OPTIONUSERLEVEL

ACCESS CONTROLKEYPADS

DATAENTRIES

AUTHORITYLEVEL

CODETYPE

blank (�) NONE ARM/DISARM1 LEVEL 1 ARM/DISARM2 LEVEL 2 ARM/DISARM

3 LEVEL 3 ARM/DISARM4 NONE ARM ONLY5 LEVEL 1 ARM ONLY

6 LEVEL 2 ARM ONLY7 LEVEL 3 ARM ONLY8 NONE SERVICE9 LEVEL 1 SERVICE

0 LEVEL 2 SERVICE

B LEVEL 3 SERVICE

Note: �Y� indicates option is enabled.

USER OPTIONSDATA

ENTRIESBLOCKED

VIEWUSER

PROGRAMBYPASS OVERVIEW

blank (�) DISABLED1 Y2 Y

3 Y Y4 Y

5 Y Y6 Y Y7 Y Y Y8 Y

9 Y Y

0 Y YB Y Y Y

C Y Y

D Y Y YE Y Y YF Y Y Y Y

Note: �Y� indicates option is enabled.

ACCESS CONTROL KEYPADS

DATAENTRIES

K.P. 1 K.P. 2 K.P. 3 K.P. 4

blank (�) NONE1 Y2 Y

3 Y Y4 Y

5 Y Y6 Y Y7 Y Y Y8 Y

9 Y Y

0 Y YB Y Y Y

C Y YD Y Y YE Y Y YF Y Y Y Y

Example: Enter a code of �123456� as�123456� (from left to right).

Note: �Y� indicates option is enabled.

ACCESS CONTROL KEYPADS

DATAENTRIES

K.P. 5 K.P. 6 K.P. 7

blank (�) NONE1 Y2 Y

3 Y Y4 Y

5 Y Y6 Y Y7 Y Y Y8

9 Y

0 YB Y Y

C YD Y YE Y YF Y Y Y

Page 10: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 10

! Press Jto save each code.

To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Programa new User Code as previously described. Press NEXT (E) button to proceed.

GEM

-RP1

CA

e2 K

eypa

d: U

ser C

odes

Example: Program a code of �2222� for user 02, with User Option of �User Program�, User �Level 3� and Access Control Option�Keypad No. 1�. Enter �2222� for a user code, �2 3� for user option and �blank(�) 1� for access control option.

CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described aboveand press Jto save. Similarly, to cancel a code, blank out each number of the code and press Jto save to save.

USER AUTHORITY LEVELKEYPAD DISPLAY FUNCTION MENU

FUNCTION LEVEL*DISPLAY ZN FAULTS 1DISPLAY ZN BYPASSED 1DISPLAY ZN DIRECTORY 1ACTIVATE BELL TEST 1DISPLAY PHONE #�S 1DISPLAY SYS TRBL 1DISPLAY FIRE ALARM 1DISPLAY FIRE TRBL 1DISPLAY OP/CL 3ACTIVATE OVERVIEW 3**ACTIVATE CHIME 1ACTIVATE WATCH 2RESET SYSTEM TRBL 3RESET SENSOR MSG 3START EXIT TIME 1FAULT FIND ***ACTIVATE LOCATE ***EZM ZONE FIND ***ACTIVATE DIALER TEST 3DISPLAY ALARM LOG 3DISPLAY TOTAL LOG 3DISPLAY FIRE LOG 3DISPLAY OP/CL LOG 3DISPLAY SYSTEM LOG 3AUTOARM IN 1-4HRS 2DISPLAY AUTOARM SCHD 3ACTIVATE PROGRAM 3**ACTIVATE DOWNLOAD 3DISPLY RF XMITTER STAT 1RELAY CONTROL 1

NOTES:* Minimum Level required to access function** Level-3 Code with appropriate user option*** Requires Dealer Code

Related User Options: �Ambush Code� (Address 0495), �Panel Access Code� (Address0490), �Dealer Security Code� (Address 0500) & �Enable User Code by Area� (Address2500-2547).

USER OPTIONS

OPTIONS EXPLANATION

Disabled User Code not active in this area.

Blocked View Allows User Code to block another code from being viewed by another user.An unblocked code cannot view a blocked code, but a blocked code canview all codes. The master user code and the dealer program code can viewall codes.

User Program User Program Option is enabled for Keypad 1 only, wherever it is connected(any area). If enabled, Level 3 must also be enabled.

Bypass Allows User Code to bypass zones.

Overview This option, along with Level 3 Authorization, enables selection ofOVERVIEW mode at a keypad. This Mode provides a system status displayof all areas at a glance.

Arm Only Prevents User Code from disarming this area.

Service A Service Code has restricted arm/disarm rights; if an area is armed with aService Code, a �SERVICE ON� appears on the GEM-RP2ASe2 keypad (a �S�on the GEM-RP1CAe2 keypad) and the area can be disarmed with any validUser Code, including a Service Code. If the area is armed with OTHER thana Service Code, it CANNOT be disarmed with a Service Code. This istypically used to allow tradesmen access to premises under control of theowner.

Access This is normally used to activate a door striker while an area is disarmed. Acode with the access option will not function as an arm/disarm code. Whenthe code is entered, the keypad will display �ENTER NOW� and the BrownWire on the keypad will become Active Low (Ground Potential) for 7seconds.

Page 11: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 11RF Transmitter Points (Press the (A) button to set cursor.)(For wireless systems only. Also see Quick Method, which follows)For each transmitter (key fob transmitters also), enter the zone number(01�48) to which the transmitter will be mapped, the 6-digit RF ID #:1-digitchecksum number printed on the transmitter and box, the point number(1�4); enter �9� for unsupervised (all points). NOTE: When programming the

ID Code number, �A� = G 0; �B� = G 1; �C� = G 2; �D� = G 3; �E� = G 4;�F� = G 5. Press Jto save. Press NEXT (E) button to proceed.

Quick Method. If a receiver is already installed in the panel, Napcotransmitter wireless points can be programmed automatically (�enrolled�)using the following procedure. NOTE: The transmitter point will be enrolledonly if the signal strength is 3 or greater.1. Enter the zone number to which the transmitter point will be mapped.

2. Press the B button to enter the Enroll Mode. The red and green LEDson the keypad will flash and the window will display as shown at left.

3. Open the loop of the point that is to be programmed (GEM-TRANS2 orGEM-TRANS4 only).

4. Install the transmitter battery. The keypad will beep to indicate that the point has been successfully enrolled. Multi-pointtransmitters can be mapped to successive zones simultaneously (Example 1) or to selected zones point by point(Example 2).Example 1. A 4-point transmitter has the RF ID number 410078:1. Map the first three points to Zones 11�13, respectively.1. Enter the Enroll mode as described in step 2 above.

2. Enter Zone �11�.

3. Open the loops of points 1, 2 and 3.

4. Install the transmitter battery. The keypad will beep 3 times to indicate that three points have been programmed.! Transmitter 410078:1, point 1 will be mapped to Zone 11.! Transmitter 410078:1, point 2 will be mapped to Zone 12.! Transmitter 410078:1, point 3 will be mapped to Zone 13.

The keypad will now display Zone 13, the last zone enrolled.

Example 2. A 2-point transmitter has the RF ID number 287613:1. Map point 1 to Zone 6 and point 2 to Zone 9.1. Enter the Enroll mode as described above.

2. Enter Zone �06�.

3. Open point-1 loop.

4. Install the battery. The keypad will beep once to indicate that one point has been programmed. (Transmitter 287613:1,point 1 will be mapped to Zone 6.)

5. Enter Zone �09�.

6. Close point-1 loop and open point-2 loop.

7. Remove the transmitter battery, then re-install it. The keypad will beep once to indicate that one point has beenprogrammed. (Transmitter 287613:1, point 2 is mapped to Zone 9.)

Zone # Xmitter Check PointMapped to ID Sum #

Z N # X M I T # + C S PZN01 -000000 : 0 - 0

Z N # X M I T # + C S PZN01 -000000 : 0 - 0

Z N # X M I T # + C S PZN01 -ENROLL :A- -

KEY FOB ZONE ASSIGNMENT: Key fobs can also be assigned to zones to allow multiple wireless panic buttons on onealarm system, each reporting to a central station, a pager or having a description on the keypad that describes the personholding the key fob, the location where the person holding the key fob is stationed, or the special purpose of the key fobbutton being depressed. See the next page on Key fob Zone Assignment.

GEM

-RP1C

Ae2 K

eypad: RF Transm

itter Points

Page 12: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 12Key Fob Transmitters (Press the (A) button to set cursor.)Keyfobs can be programmed as �Arm/Disarm� devices (refer to WI752).For each Key Fob Transmitter, enter:! the Key Fob Transmitter number (01�08).! area number to which transmitter is assigned (1-2); enter 0 to disable

keyfob.! the 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters, including

leading �0�s, if any).! 1-digit checksum number printed on the transmitter (enter all numbers and/or letters,

including leading �0�s, if any).! Aux-1 Option (see key fob aux 1 & aux 2 options).! Aux-2 Option (see key fob aux 1 & aux 2 options).Note: If the Key Fob is converted for Two Button �Emergency Use� (by cutting an internaljumper), both top or bottom buttons must be depressed to activate an alarm. In this case,Aux-1 and Aux-2 cannot be programmed. Press Jto save. Press NEXT (E) button toproceed.

Key Fob Zone Assignment (refer to display as shown on the previous page: press the (F) button to go backwards.)Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 =point 3; A2 = point 4. Up to 48 key fobs (using 1 button) or 24 key fobs (using 2 buttons) or 14 key fobs (using all 4buttons) or any combination up to a maximum of 48 controlled zones can be assigned, providing multiple wireless panicbuttons on a system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zonenumber with description/location. To assign a key fob to a zone: program the key fob as you would a transmitter, enteringthe key fob's ID code, check sum and point number at the appropriate zone. The �Quick Method� is not allowed. The zonemay be hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output). NOTE: Ifassigning a key fob to a zone, the �ON/OFF� buttons on the key fob will no longer arm/disarm the system. The key fob isconverted to a �panic only� device.

Enter Zone and Interior DescriptionsPress the 1 and 2 buttons to place the cursor; press the 3and 6 buttons to select the character. For each zone, enter adescription of up to two lines. Press Jto save each description. To proceed

to the next description, place the cursor under the Zone Number (e.g. �01�) and change the Zone Number using the3 and 6 buttons. Program a new description as above. NOTE: Zone Descriptions can only be entered throughthe GEM-/RP1CAe2 Keypad or by using the Napco Quickloader Software. Press NEXT (E) button to proceed.

Enter Date (Press the (A) button to set cursor.)Enter the current date in the format MM/DD/YY, where MM = the month(01�12); DD=the day (01�31); and YY=the year. Press Jto save. PressNEXT (E) button to proceed.

KF A XMIT#+ CS OP0 1 - 0 0 0 0 0 0 0 : 0 0 0

DATAENTRY

AUX 1/AUX 2 OPTIONS

0 None1 Relay Group 1 Toggle2 Relay Group 2 Toggle9 PanicA AuxiliaryB InstantC Aux. Output ToggleD Access on Aux. Output

NOTE: Key fobs 1-8 report openings andclosings as Users 25-32.

GEM

-RP1

CA

e2 K

eypa

d: K

eyfo

b Tr

ansm

itter

s, Z

one

Des

crip

tions

& D

ate

(Direct Entry)

01-______________________________

(Direct Entry)

E N T E R D A T E ( 0 1/ 0 1/ 9 9 )

Page 13: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 13

Enter Time (Press the (A) button to set cursor.)Enter the current time in the format HH:MMA/P, where HH=hours (01�12);MM=minutes (00�59). Select Am or Pm by pressing any number button,then press Jonce again to save.

Dealer CodeDirectly enter the Dealer Code, including leading zeros. Use the 1through 9 buttons. NOTE: Press the 0 button for a zero. PressJto save.

Re-enter the Dealer Code to verify the previous code. Press Jto save.Press NEXT (E) button to proceed.NOTE: The Dealer Code can be two or more digits (up to 6 digits).

CLEAR PROGRAM: Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode,press the C button to enter the Address Program Mode; (b) access Location 4091 (Clear Program) or 4093 (ColdStart); (c) press Jand then (d) press the C button to exit the Dealer Program Mode. A �SYSTEM TROUBLE/E09-00

SERVICE� will occur. Press the C button to silence the keypad.

(Direct Entry)

E N T E R T I M E ( 1 2 : 0 5 A )

(Direct Entry)

DEALER CODE�� � � � �

(Direct Entry)

DEALER CODERE-ENTER

EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the C button to enter theDirect Address Program Mode for further programming or press the C button once again to end all programming andresume normal keypad operation.

Clear Dealer Program (Erases Dealer Program)

This erases the dealer program. Use this feature to start acustomized default program. Program Data and SystemStatus Memory is erased where Scheduled Data and ZoneDescriptions are maintained.

Access address 4091, then press the Jbutton. Data entry is not allowed.NOTE: Enter Easy Menu Driven Program Mode to program system again.

GEM-RP1CAe2 Keypad

4091 � �

Cold Start (Erases Entire Program)

This erases the entire program including Program Data,Zone Description Data, System Status Data, Schedule Dataand Foreign Language configuration(similar to a newpanel).

Access address 4093, then press the Jbutton. Data entry is not allowed.NOTE: Some features (schedules) can only be programmed again with theDownloading Software.

GEM-RP1CAe2 Keypad

4093 � �

GEM

-RP1C

Ae2 K

eypad: Time, D

ealer Code &

Exit Dealer Program

Mode

Page 14: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 14

B. GEM-RP2ASe2 KeypadEnter the Master Security Code (printed on microprocessor can) for a new panel or enter your customDealer Program Code if programmed. Press A followed by NO (F) repeatedly until �TURNON/PROG� is displayed. NOTE: If you pass �TURNON/PROG�, you can scroll back by pressing the Bbutton. Press YES (E) to enter the Dealer Program Mode. This keypad displays messages inmultiple segments. Press the A button to scroll through each segment.

Total Number of Zones in Area 1 & Area 2 (Appears for New Panel Only)Directly enter the total number of zones to be programmed for Area 1 andArea 2, respectively. Valid entries are from 01 to 48. Directly enter the totalnumber of zones, including leading zeros. Use number buttons 1through 9. NOTE: Press the 0 button for a zero. The system isbased on groups of 4 zones each (after the first 8 zones), and willautomatically round up to the next group of 4. For example, if you enter 18,it will automatically convert this to 20 zones. Press Jto save. Press NEXT(E) button to proceed.

Note: The GEM-P3200 is limited to a combined maximum of 48 zones and7 keypads. All 48 zones and 7 keypads may be programmed in the EZProgram Mode. For more options, see Zone and Keypad Options in DirectAddress Programming.

Fire Zones (Appears for New Panel Only)Enter the zone number of any Fire Zones (both 2-wire, 4-wire or wireless).Valid entries are from 01 to 48. Directly enter each zone number, includingleading zeros, and press Jto save, and then repeat for any additionalzone(s). Press NEXT (E) button to proceed.NOTE: If you are programming a 2 Area system, enter the zone number ofzones required for Areas 1 & 2. All fire zones are common to areas 1 and 2.The Direct Address Program Mode can then be used to customize them asneeded. See Zone Options.

2-Wire Fire Zones (Appears for New Panel Only)Enter the zone number of any Fire Zones (from previous question) whichare to be used with 2-wire smoke detectors. The only valid entries are 07and 08. Directly enter each zone number, including leading zeros. PressJto save, and then repeat for any additional zone. NOTE: Only zones whichhave been designated as Fire Zones can be programmed as 2 Wire Firezones. Press NEXT (E) button to proceed. NOTE: JP7 must be set to�2-WF� position for 2-wire fire zones 7 and 8 (refer to InstallationInstructions).

R

COMPUTERIZED SECURITY SYSTEM

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

GEMINI

ENT A1 A1#Z08

(Direct Entry)

ENT A1

#ZN08

(Direct Entry)

ENT A2

#ZN00

(Direct Entry)

ENT FR

ZN#00

(Direct Entry)

ENT2WF

ZN# 00

GEM

-RP2

ASe

2 K

eypa

d: Z

ones

/Key

pads

per

Are

a, F

ire Z

ones

& 2

-Wire

Fire

Zon

es

Page 15: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 15

Local System or C.S. Reporting System (Appears for New Panel Only)Press YES (E) button for all zones to report; press NO (F) buttonfor no zones to report (LOCAL SYSTEM).

Exit/Entry Zones (Appears for New Panel Only)Directly enter the zone numbers which are to be used as Exit/Entry zones.Valid entries are from 01 to 48. Directly enter each zone number, includingleading zeros. Use number buttons 1 through 9. NOTE: Pressthe 0 button for a zero. Press Jto save and then repeat for anyadditional zone(s). Press NEXT (E) button to proceed.NOTE: Exit/Entry Zones will have an entry delay of 30 seconds and an exitdelay of 60 seconds. Chime will automatically be programmed for all E/Ezones. If you are programming a 2 Area system, enter all of the zonesrequired for Areas 1 & 2.

Interior Zones (Appears for New Panel Only)Directly enter the zone numbers which are to be used as Interior Zones.Valid entries are from 01 to 48. Directly enter each zone number, includingleading zeros. Use number buttons 1 through 9. NOTE: Pressthe 0 button for a zero. Press Jto save and then repeat for anyadditional zone(s). Press NEXT (E) button to proceed.NOTE: All Interior zones will also be automatically programmed as �Exit/Entry Follower� zones. If you are programming a 2 Area system, enter allthe zones required for Areas 1 & 2.

Number of Keypads in Area 1Directly enter the total number of Keypads to be installed in Area 1. Validentries are from 01 to 07. Directly enter the number of keypads, includingleading zeros. Use number buttons 1 through 9. NOTE: Pressthe 0 button for a zero. Press Jto save . Press NEXT (E) buttonto proceed.

Number of Keypads in Area 2Directly enter the total number of Keypads to be installed in Area 2. Validentries are from 01 to 07. Directly enter the number of keypads, includingleading zeros. Use number buttons 1 through 9. NOTE: Pressthe 0 button for a zero. Press Jto save . Press NEXT (E) buttonto proceed.

(Press YES or NO)

REPORT

ALL ZN?

Y/N

(Direct Entry)

ENT EE

ZN# 00

(Direct Entry)

ENTFOL

ZN# 00

ENT A1

#KP 01

(Direct Entry)

ENT A2

#KP 00

GEM

-RP2A

Se2 Keypad: C

S Reporting, Exit/Entry Zones, Interior Zones &

Keypads per A

rea

Page 16: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 16

Central Station Receiver 1 Telephone NumberPress the A button to scroll screens. Using number buttons, entertelephone number of up to 10 digits including prefix letters, if necessary, forreceiver 1. Use number buttons 1 through 9 for digits 1�9; pressthe G 0 button for a zero and G 1 through G5 for letters B�F, respectively. NOTE: Pre-Dial Delay = �D�; Dial-ToneDetection = �E�. Pressing the 0 button will produce a blank space (�).Press Jto save. Press NEXT (E) button to proceed.NOTE: The GEM-RP2ASe2 keypad provides a maximum of 10 digits in thismode. To program additional digits, go to the Direct Address Program Modeand continue from Location 0537. Central Station Receiver 2 and 3Telephone Numbers can only be entered in Direct Address Programming.See CS Receiver Options.

Central Station Receiver 1 Account NumberPress the A button to scroll screens. Enter an account number of up tofour digits. Use number buttons 1 through 9 for digits 1�9. NOTE:Press the G0 button for a zero and press 0 button for ablank space (�). Press G 1 through G 4 for letters B�E,respectively.Press Jto save . Press NEXT (E) button to proceed.NOTE: Central Station Receiver 2 and 3 Account Numbers can only beentered in Direct Address Programming. See CS Reporting Options.

Central Station Receiver 1 FormatPress the A button to scroll screens. From the table below, enter thecentral station's receiver format. Use number buttons 1 through9. NOTE: Press the G 0 button for a zero and press 0for a blank space (�). Press G 1 through G 4 for lettersB�E, respectively.Press Jto save. Press NEXT (E) button to proceed.

(Direct Entry)

PHONE#

______

______

(Direct Entry)

ACC#

(____)

(Direct Entry)

REC FMT

(0)

DATAENTRY

CS RECEIVER 1 FORMAT

blank(�) Ademco Slow, Silent Knight Slow1 Sescoa, Vertex, DCI, Franklin

Fast2 Radionics Fast3 Silent Knight Fast4 Radionics, DCI, Franklin Slow5 Universal High Speed8 Radionics BFSK9 FBI 4/3/10 Radionics Modem 2B SIAC Ademco Point IDD Ademco ExpressE Pager

NOTE: Modem IIe format is available only in Direct AddressProgramming. Central Station Receiver 2 and 3 Formats can only beentered in Direct Address Programming. See CS Receiver Options.G

EM-R

P2A

Se2

Key

pad:

CS

Tel.

No.

, CS

Acc

t. N

o. &

CS

Form

at

Page 17: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 17Enter User Codes (Press the (A) button to set cursor.)Enter up to 48 User Codes with User Options, Authority Level and AccessControl Options (if necessary) for each code. Refer to the tables below andon the next page for available data entries for User Options, Authority Leveland Access Control Options. Note: All 48 Users must be assigned to areasin �Enable User Code by Area� (Address 2500-2547) in Direct AddressProgramming. By default, only User 1 is enabled in Area 1 and Area 2.User 2 - 8 are enabled in Area 1 and user 9 - 16 are enabled in Area 2! Press the (A) button to set the cursor to the User Number. Use thenumber buttons 1 through 9 to enter the User Number.

! Press the (A) button once to set the cursor to the User Code. Usethe number buttons 1 through 9 to enter a code of up to 6 digits.Enter up to 6 digits (4 digits is recommended) in the first six boxes from leftto right for each user code. Valid entries are: 0-9. Note: Press the 0button for a zero. No blank spaces in between; leave blank (�) any trailingboxes. If an �Ambush Code� (Address 0495) is entered, do not program the

first two digits of ANY User Code as the same digits entered for the �Ambush Code�.! If the programmed code was less than 6 digits, press the A button to set the cursor to the OPTION/LEVEL.

Refer to the tables shown for the available data entries. Enter the options data in the left digit. Enter the level data (with arming options, if any, added) in the right digit. Note: For entries greater than 9, press the G1 buttons through the G5 buttons for B through F, respectively.

! For Keypad Access Control, press the A button once again to program applicable keypads. Refer to the tables shown, use the number buttons to enter the data for Keypad 1�4 data in the right digit; and the data for Keypad 5�7 data in the left digit. (Press the 0 button for blank.)

(Direct Entry)

USER01

123___

OPT F3

ACC_

USER OPTIONSUSER CODE

(UP TO 6 DIGITS)USER

OPTIONUSERLEVEL

ACCESS CONTROLKEYPADS

DATAENTRIES

AUTHORITYLEVEL

CODETYPE

blank (�) NONE ARM/DISARM1 LEVEL 1 ARM/DISARM2 LEVEL 2 ARM/DISARM

3 LEVEL 3 ARM/DISARM4 NONE ARM ONLY5 LEVEL 1 ARM ONLY

6 LEVEL 2 ARM ONLY7 LEVEL 3 ARM ONLY

8 NONE SERVICE9 LEVEL 1 SERVICE

0 LEVEL 2 SERVICEB LEVEL 3 SERVICE

Note: �Y� indicates option is enabled.

USER OPTIONSDATA

ENTRIESBLOCKED

VIEWUSER

PROGRAMBYPASS OVERVIEW

blank (�) DISABLED1 Y2 Y

3 Y Y4 Y

5 Y Y6 Y Y

7 Y Y Y8 Y

9 Y Y0 Y YB Y Y YC Y Y

D Y Y Y

E Y Y YF Y Y Y Y

Note: �Y� indicates option is enabled.

ACCESS CONTROL KEYPADS

DATAENTRIES

K.P. 1 K.P. 2 K.P. 3 K.P. 4

blank (�) NONE1 Y2 Y

3 Y Y4 Y5 Y Y

6 Y Y7 Y Y Y

8 Y9 Y Y0 Y YB Y Y Y

C Y Y

D Y Y YE Y Y Y

F Y Y Y Y

Example: Enter a code of �123456� as�123456� (from left to right).

Note: �Y� indicates option is enabled.

ACCESS CONTROL KEYPADS

DATAENTRIES

K.P. 5 K.P. 6 K.P. 7

blank (�) NONE1 Y2 Y

3 Y Y4 Y5 Y Y

6 Y Y7 Y Y Y

89 Y0 YB Y Y

C Y

D Y YE Y Y

F Y Y Y

GEM

-RP2A

Se2 Keypad: U

ser Codes

Page 18: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 18KEYPAD DISPLAY FUNCTION MENU

FUNCTION LEVEL*DISPLAY ZN FAULTS 1DISPLAY ZN BYPASSED 1DISPLAY ZN DIRECTORY 1ACTIVATE BELL TEST 1DISPLAY PHONE #�S 1DISPLAY SYS TRBL 1DISPLAY FIRE ALARM 1DISPLAY FIRE TRBL 1DISPLAY OP/CL 3ACTIVATE OVERVIEW 3**ACTIVATE CHIME 1ACTIVATE WATCH 2RESET SYSTEM TRBL 3RESET SENSOR MSG 3START EXIT TIME 1FAULT FIND ***ACTIVATE LOCATE ***EZM ZONE FIND ***ACTIVATE DIALER TEST 3DISPLAY ALARM LOG 3DISPLAY TOTAL LOG 3DISPLAY FIRE LOG 3DISPLAY OP/CL LOG 3DISPLAY SYSTEM LOG 3AUTOARM IN 1-4HRS 2DISPLAY AUTARM SCHD 3ACTIVATE PROGRAM 3**ACTIVATE DOWNLOAD 3DISPLY RF XMITTER STAT 1RELAY CONTROL 1

CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described aboveand press Jto save. Similarly, to cancel a code, blank out each number of the code, press Jto save.

Example: Program a code of �2222� for user 02, with User Option of �User Program�, User �Level 3� and Access Control Option �Keypad No. 1�. Enter�2222� for a user code, �2 3� for user option and �blank(�) 1� for access control option.

! Press Jto save each code.

To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Program anew User Code as previously described. Press NEXT (E) button to proceed.

NOTES:* Minimum Level required to access function** Level-3 Code with appropriate user option*** Requires Dealer Code

Related User Options: �Ambush Code� (Address 0495), �Panel Access Code� (Address0490), �Dealer Security Code� (Address 0500) & �Enable User Code by Area� (Address2500-2547).

USER OPTIONS

OPTIONS EXPLANATION

Disabled User Code not active in this area.

Blocked View Allows User Code to block another code from being viewed by another user.An unblocked code cannot view a blocked code, but a blocked code canview all codes. The master user code and the dealer program code can viewall codes.

User Program User Program Option is enabled for Keypad 1 only, wherever it is connected(any area). If enabled, Level 3 must also be enabled.

Bypass Allows User Code to bypass zones.

Overview This option, along with Level 3 Authorization, enables selection ofOVERVIEW mode at a keypad. This Mode provides a system status displayof all areas at a glance.

Arm Only Prevents User Code from disarming this area.

Service A Service Code has restricted arm/disarm rights; if an area is armed with aService Code, a �SERVICE ON� appears on the GEM-RP2ASe2 keypad (a �S�on the GEM-RP1CAe2 keypad) and the area can be disarmed with any validUser Code, including a Service Code. If the area is armed with OTHER thana Service Code, it CANNOT be disarmed with a Service Code. This istypically used to allow tradesmen access to premises under control of theowner.

Access This is normally used to activate a door striker while an area is disarmed. Acode with the access option will not function as an arm/disarm code. Whenthe code is entered, the keypad will display �ENTER NOW� and the BrownWire on the keypad will become Active Low (Ground Potential) for 7seconds.

GEM

-RP2

ASe

2 K

eypa

d: U

ser C

odes

Page 19: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 19RF Transmitter Points (Press the (A) button to set cursor.)(For wireless systems only. Also see Quick Method, which follows)For each transmitter (key fob transmitters also), enter the zone number(01�48) to which the transmitter will be mapped, the 6-digit RF ID #:1-digitchecksum number printed on the transmitter and box, the point number(1�4); enter �9� for unsupervised (all points). NOTE: When programming theID Code number, �A� = G 0; �B� = G 1; �C� = G2; �D� = G 3; �E� = G 4; �F� = G 5. PressJto save. Press NEXT (E) button to proceed.

Quick Method. If a receiver is already installed in the panel, Napcotransmitter wireless points can be programmed automatically (�enrolled�)using the following procedure. NOTE: The transmitter point will be enrolledonly if the signal strength is 3 or greater.1. Enter the zone number to which the transmitter point will be mapped.

2. Press the B button to enter the Enroll Mode. The red and green LEDson the keypad will flash and the window will display as shown at left.

3. Open the loop of the point that is to be programmed (GEM-TRANS2 orGEM-TRANS4 only).

4. Install the transmitter battery. The keypad will beep to indicate that thepoint has been successfully enrolled. Multi-point transmitters can be mappedto successive zones simultaneously (Example 1) or to selected zones pointby point (Example 2).

Example 1. A 4-point transmitter has the RF ID number 410078:1. Map the first three points to Zones 11�13, respectively.1. Enter the Enroll mode as described in step 2 above.

2. Enter Zone �11�.

3. Open the loops of points 1, 2 and 3.

4. Install the transmitter battery. The keypad will beep 3 times to indicate that three points have been programmed.! Transmitter 410078:1, point 1 will be mapped to Zone 11.! Transmitter 410078:1, point 2 will be mapped to Zone 12.! Transmitter 410078:1, point 3 will be mapped to Zone 13.

The keypad will now display Zone 13, the last zone enrolled.

Example 2. A 2-point transmitter has the RF ID number 287613:1. Map point 1 to Zone 6 and point 2 to Zone 9.1. Enter the Enroll mode as described above.

2. Enter Zone �06�.

3. Open point-1 loop.

4. Install the battery. The keypad will beep once to indicate that one point has been programmed. (Transmitter 287613:1,point 1 will be mapped to Zone 6.)

5. Enter Zone �09�.

6. Close point-1 loop and open point-2 loop.

7. Remove the transmitter battery, then re-install it. The keypad will beep once to indicate that one point has beenprogrammed. (Transmitter 287613:1, point 2 is mapped to Zone 9.)

(Direct Entry)

ZN#01

000000

:0 PT0

(Direct Entry)

ZN#11

ENROLL

:0 PT-

KEY FOB ZONE ASSIGNMENT: Key fobs can also be assigned to zones to allow multiple wireless panic buttons on onealarm system, each reporting to a central station, a pager or having a description on the keypad that describes the personholding the key fob, the location where the person holding the key fob is stationed, or the special purpose of the key fobbutton being depressed. See the next page on Key fob Zone Assignment.

GEM

-RP2A

Se2 Keypad: R

F Transmitter Points

Page 20: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 20

Key Fob Transmitters (Press the (A) button to set cursor.)Press the (A) button to set cursor. Keyfobs can be programmed as�Arm/Disarm� devices (refer to WI752). For each Key Fob Transmitter, enter:! the Key Fob Transmitter number (01�08).! area number to which transmitter is assigned (1 or 2); enter 0 to disable key fob.! the 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters,including leading �0�s, if any).! 1-digit checksum number printed on the transmitter (enter all numbers and/orletters, including leading �0�s, if any).! Aux-1 Option (see key fob aux 1 & aux 2 options).! Aux-2 Option (see key fob aux 1 & aux 2 options).

Note: If the Key Fob is converted for Two Button �Emergency Use� (bycutting an internal jumper), both top or bottom buttons must bedepressed to activate an alarms. In this case, the Aux-1 and Aux-2cannot be programmed.Press Jto save. Press NEXT (E) button to proceed.

Key Fob Zone Assignment (refer to display as shown on theprevious page: press the (F) button to go backwards.)Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 =point 3; A2 = point 4. Up to 48 key fobs (using 1 button) or 24 key fobs (using 2 buttons) or 14 key fobs (using all 4buttons) or any combination up to a maximum of 48 controlled zones can be assigned, providing multiple wireless panicbuttons on a system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zonenumber with description/location. To assign a key fob to a zone: program the key fob as you would a transmitter, enteringthe key fob's ID code, check sum and point number at the appropriate zone. The �Quick Method� is not allowed. The zonemay be hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output). NOTE: Ifassigning a key fob to a zone, the �ON/OFF� buttons on the key fob will no longer arm/disarm the system. The key fob isconverted to a �panic only� device.

(Direct Entry)

KFOB01

AREA 0

000000

:0 0 0

DATAENTRY

AUX 1/AUX 2OPTIONS

0 None1 Relay Group 1 Toggle2 Relay Group 2 Toggle9 Panic

DATAENTRY

AUX 1/AUX 2OPTIONS

A AuxiliaryB InstantC Aux. Output ToggleD Access on Aux.

Output

NOTE: Key fobs 1-8report openings andclosings as Users 25-32.

GEM

-RP2

ASe

2 K

eypa

d: K

eyfo

b Tr

ansm

itter

s

ZONE DESCRIPTIONS: GEM-RP2ASe2 cannot be used to enter Zone Descriptions. To enter Zone Descriptions youmust use the GEM-RP1CAe2 Keypad or the Napco Quickloader Software.

Page 21: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 21

Enter Date (Press the (A) button to set cursor.)Enter the current date in the format MM/DD/YY, where MM = the month(01�12); DD=the day (01�31); and YY=the year. Press Jto save. PressNEXT (E) button to proceed.

Enter Time (Press the (A) button to set cursor.)Enter the current time in the format HH:MMA/P, where HH=hours (01�12);MM=minutes (00�59). Select Am or Pm by pressing any number button,then press Jonce again to save.

Dealer CodeDirectly enter the Dealer Code, including leading zeros. Use the 1through 9 buttons. NOTE: Press the 0 button for a zero. PressJto save.

Re-enter the Dealer Code to verify the previous code. Press Jto save.Press NEXT (E) button to proceed.NOTE: The Dealer Code can be two or more digits (up to 6 digits).

CLEAR PROGRAM: Should it be necessary to create a new custom default program, (a) from the Dealer ProgramMode, press the C button to enter the Address Program Mode; (b) access Location 4091 (Clear Program) or 4093(Cold Start); (c) press Jand then (d) press the C button to exit the Dealer Program Mode. A System TroubleCondition will occur. Press the C button to silence the keypad.

(Direct Entry)

DATE

07/18

/96

(Direct Entry)

TIME

09:10A

EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the C button to enter theDirect Address Program Mode for further programming or press the C button once again to end all programmingand resume normal keypad operation.

(Direct Entry)

DCODE

(Direct Entry)

RE-ENT

(Direct Entry)

������

GEM

-RP2A

Se2 Keypad: D

ate, Time, D

ealer Code &

Exit Dealer Program

Mode

Page 22: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 22

B. GEM-RP3DGTL KeypadEnter the Master Security Code (printed on microprocessor can) for a new panel or enter your customDealer Program Code if programmed. Press A, followed by NO (F) repeatedly until �17� isdisplayed. NOTE: If you pass Function �17�, you can scroll back by pressing the B button. PressYES (E) to enter the Dealer Program Mode. The GEM-RP3DGTL is a dual 7-segment digitalkeypad. The questions will be in the form of a 2 digit number flashing in the digital display. Press theA button to scroll through each segment.

Total Number of Zones in Area 1 & Area 2 (Appears for New Panel Only)Directly enter the total number of zones to be programmed for Area 1 andArea 2, respectively. Valid entries are from 01 to 48. Directly enter the totalnumber of zones, including leading zeros. Use number buttons 1through 9. NOTE: Press the 0 button for a zero. The system isbased on groups of 4 zones each (after the first 8 zones), and willautomatically round up to the next group of 4. For example, if you enter 18,it will automatically convert this to 20 zones. Press Jto save. Press NEXT(E) button to proceed.Note: The GEM-P3200 is limited to a combined maximum of 48 zones and7 keypads. All 48 zones and 7 keypads may be programmed in the EZProgram Mode. For more options, see Zone and Keypad Options in DirectAddress Programming.

Fire Zones (Appears for New Panel Only)Enter the zone number of any Fire Zones (both 2-wire, 4-wire or wireless).Valid entries are from 01 to 48. Directly enter each zone number, includingleading zeros, and press Jto save, and then repeat for any additionalzone(s). Press NEXT (E) button to proceed.NOTE: If you are programming a 2 Area system, enter the zone number ofzones required for Areas 1 & 2. All fire zones are common to areas 1 and 2.The Direct Address Program Mode can then be used to customize them asneeded. See Zone Options.

2-Wire Fire Zones (Appears for New Panel Only)Enter the zone number of any Fire Zones (from previous question) whichare to be used with 2-wire smoke detectors. The only valid entries are 07and 08. Directly enter each zone number, including leading zeros. PressJto save, and then repeat for any additional zone. NOTE: Only zoneswhich have been designated as Fire Zones can be programmed as 2 WireFire zones. Press NEXT (E) button to proceed. NOTE: JP7 must be setto �2-WF� position for 2-wire fire zones 7 and 8 (refer to InstallationInstructions).

Local System or C.S. Reporting System (Appears for New Panel Only)Press YES (E) button for all zones to report; press NO (F) buttonfor no zones to report (LOCAL SYSTEM).

R

COMPUTERIZED SECURITY SYSTEM

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

GEMINI

ENT A1 1 7INT ERIOR BYPASS FIRE/TBL SYS T BL CHIM E

(Direct Entry)

04 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

(Direct Entry)

05 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

(Yes or No)

06 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

GEM

-RP3

DG

TL K

eypa

d: Z

ones

per

Are

a, F

ire Z

ones

, 2-W

ire F

ire Z

ones

& C

S R

epor

ting

(Direct Entry)

01 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

(Direct Entry)

02 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

Flashing

Page 23: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 23Exit/Entry Zones (Appears for New Panel Only)Directly enter the zone numbers which are to be used as Exit/Entry zones.Valid entries are from 01 to 48. Directly enter each zone number, includingleading zeros. Use number buttons 1 through 9. NOTE: Press the0 button for a zero. Press Jto save and then repeat for any additionalzone(s). Press NEXT (E) button to proceed.NOTE: Exit/Entry Zones will have an entry delay of 30 seconds and an exitdelay of 60 seconds. Chime will automatically be programmed for all E/Ezones. If you are programming a 2 Area system, enter all of the zonesrequired for Areas 1 & 2.

Interior Zones (Appears for New Panel Only)Directly enter the zone numbers which are to be used as Interior Zones. Validentries are from 01 to 48 Directly enter each zone number, including leadingzeros. Use number buttons 1 through 9. NOTE: Press the 0button for a zero. Press Jto save and then repeat for any additional zone(s).Press NEXT (E) button to proceed.NOTE: All Interior zones will also be automatically programmed as �Exit/Entry Follower� zones. If you are programming a 2 Area system, enter all thezones required for Areas 1 & 2.

Number of Keypads in Area 1Directly enter the total number of Keypads to be installed in Area 1. Validentries are from 01 to 07. Directly enter the number of keypads, includingleading zeros. Use number buttons 1 through 9. NOTE: Press the0 button for a zero. Press Jto save . Press NEXT (E) button toproceed.

Number of Keypads in Area 2Directly enter the total number of Keypads to be installed in Area 2. Validentries are from 01 to 07. Directly enter the number of keypads, includingleading zeros. Use number buttons 1 through 9. NOTE: Press the0 button for a zero. Press Jto save . Press NEXT (E) button toproceed.

Central Station Receiver 1 Telephone NumberUsing number buttons, enter telephone number of up to 16 digits includingprefix letters, if necessary, for receiver 1. Use number buttons 1 through9 for digits 1�9; press the G 0 button for a zero and G1 through G 5 for letters B�F, respectively. NOTE: Pre-DialDelay = �D�; Dial-Tone Detection = �E�. Pressing the 0 button willproduce a blank space (�). Press Jto save. Press NEXT (E) to proceed.NOTE: Central Station Receiver 2 and 3 Telephone Numbers can only beentered in Direct Address Programming. See CS Receiver Options.

(Direct Entry)

07 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

(Direct Entry)

08 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

(Direct Entry)

09 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

GEM

-RP3D

GTL K

eypad: Exit/Entry Zones, Interior Zones, Keypads per A

rea & C

S Tel. No.

(Direct Entry)

10 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

(Direct Entry)

11 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

Page 24: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 24

Central Station Receiver 1 Account NumberEnter an account number of up to four digits. Use number buttons 1through 9 for digits 1�9. NOTE: Press the 0 button for a zero andpress the G 0 buttons for a blank space (�). Press Jto save .Press NEXT (E) button to proceed. NOTE: Central Station Receiver 2and 3 Account Numbers can only be entered in Direct AddressProgramming. See CS Reporting Options.

Central Station Receiver 1 FormatFrom the table below, enter the central station's receiver format. Usenumber buttons 1 through 9. NOTE: Press the 0 button fora zero. and press the G 0 buttons for a blank space (�). PressG 1 through G 4 for letters B�E, respectively.Press Jto save. Press NEXT (E) button to proceed.

DATAENTRY

CS RECEIVER 1 FORMAT

blank(�) Ademco Slow, Silent Knight Slow1 Sescoa, Vertex, DCI, Franklin

Fast2 Radionics Fast3 Silent Knight Fast4 Radionics, DCI, Franklin Slow5 Universal High Speed8 Radionics BFSK

DATAENTRY

CS RECEIVER 1 FORMAT

9 FBI 4/3/10 Radionics Modem 2B SIAC Ademco Point IDD Ademco ExpressE Pager

NOTE: Modem IIe is available only in DirectAddress Programming. Central StationReceiver 2 and 3 Formats can only be enteredin Direct Address Programming. See CSReceiver Options.

(Direct Entry)

13 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

GEM

-RP3

DG

TL K

eypa

d: C

S A

cct.

No.

& C

S Fo

rmat

(Direct Entry)

12 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

Page 25: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 25Enter User Codes (Press the (A) button to set cursor.)Enter up to 48 User Codes with User Options, Authority Level and AccessControl Options (if necessary) for each code. Refer to the tables below andon the next page for available data entries for User Options, Authority Leveland Access Control Options. Note: All 48 Users must be assigned to areasin �Enable User Code by Area� (Address 2500-2547) in Direct AddressProgramming. By default, only User 1 is enabled in Area 1 and Area 2.User 2 - 8 are enabled in Area 1 and user 9 - 16 are enabled in Area 2

! Press the (A) button once to set the cursor to the User Code. Usethe number buttons 1 through 9 to enter a code of up to 6 digits. Enter up to 6 digits (4 digits arerecommended) in the first six boxes from left to right for each user code. Valid entries are: 0-9. Note: Press the 0button for a zero. No blank spaces in between; leave blank (�) any trailing boxes. If an �Ambush Code� (Address 0495)is entered, do not program the first two digits of ANY User Code as the same digits entered for the �Ambush Code�.

! If the programmed code is less than 6 digits, press the A button to set the cursor to the OPTION/LEVEL. Refer to the tables below for the available User Option and User Level data entries. Enter the user options data in the left digit. Enter the level data (with arming options, if any, added) in the right digit. Note: For entries greater than 9, press the G1 buttons through the G5 buttons for B through F, respectively.

! For Keypad Access Control, press the A button once again to program applicable keypads. Refer to the tables below, use the number buttons to enter the data for Keypad 1�4 in the right digit; and the data for Keypad 5�7 data in the left digit. (Press the 0 buttons for blank.)

USER OPTIONSUSER CODE

(UP TO 6 DIGITS)USER

OPTIONUSERLEVEL

ACCESS CONTROLKEYPADS

DATAENTRIES

AUTHORITYLEVEL

CODETYPE

blank (�) NONE ARM/DISARM1 LEVEL 1 ARM/DISARM2 LEVEL 2 ARM/DISARM

3 LEVEL 3 ARM/DISARM4 NONE ARM ONLY5 LEVEL 1 ARM ONLY

6 LEVEL 2 ARM ONLY7 LEVEL 3 ARM ONLY8 NONE SERVICE

9 LEVEL 1 SERVICE0 LEVEL 2 SERVICE

B LEVEL 3 SERVICE

Note: �Y� indicates option is enabled.

USER OPTIONSDATA

ENTRIESBLOCKED

VIEWUSER

PROGRAMBYPASS OVERVIEW

blank (�) DISABLED1 Y2 Y

3 Y Y4 Y

5 Y Y6 Y Y7 Y Y Y

8 Y9 Y Y

0 Y YB Y Y Y

C Y YD Y Y YE Y Y YF Y Y Y Y

Note: �Y� indicates option is enabled.

ACCESS CONTROL KEYPADS

DATAENTRIES

K.P. 1 K.P. 2 K.P. 3 K.P. 4

blank (�) NONE1 Y2 Y

3 Y Y4 Y5 Y Y6 Y Y7 Y Y Y

8 Y9 Y Y0 Y YB Y Y Y

C Y Y

D Y Y YE Y Y YF Y Y Y Y

Example: Enter a code of �123456� as�123456� (from left to right).

Note: �Y� indicates option is enabled.

ACCESS CONTROL KEYPADS

DATAENTRIES

K.P. 5 K.P. 6 K.P. 7

blank (�) NONE1 Y2 Y

3 Y Y4 Y5 Y Y6 Y Y7 Y Y Y

89 Y0 YB Y Y

C Y

D Y YE Y YF Y Y Y

(Direct Entry)

14 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

GEM

-RP3D

GTL K

eypad: User C

odes

Page 26: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 26

! Press Jto save each code.

To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Programa new User Code as previously described. Press NEXT (E) button to proceed.

GEM

-RP3

DG

TL K

eypa

d: U

ser C

odes

Example: Program a code of �2222� for user 02, with User Option of �User Program�, User �Level 3� and Access Control Option�Keypad No. 1�. Enter �2222� for a user code, �2 3� for user option and �blank(�) 1� for access control option.

CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described aboveand press Jto save. Similarly, to cancel a code, blank out each number of the code press Jto save to save.

USER AUTHORITY LEVELKEYPAD DISPLAY FUNCTION MENU

FUNCTION LEVEL*DISPLAY ZN FAULTS 1DISPLAY ZN BYPASSED 1DISPLAY ZN DIRECTORY 1ACTIVATE BELL TEST 1DISPLAY PHONE #�S 1DISPLAY SYS TRBL 1DISPLAY FIRE ALARM 1DISPLAY FIRE TRBL 1DISPLAY OP/CL 3ACTIVATE OVERVIEW 3**ACTIVATE CHIME 1ACTIVATE WATCH 2RESET SYSTEM TRBL 3RESET SENSOR MSG 3START EXIT TIME 1FAULT FIND ***ACTIVATE LOCATE ***EZM ZONE FIND ***ACTIVATE DIALER TEST 3DISPLAY ALARM LOG 3DISPLAY TOTAL LOG 3DISPLAY FIRE LOG 3DISPLAY OP/CL LOG 3DISPLAY SYSTEM LOG 3AUTOARM IN 1-4HRS 2DISPLAY AUTARM SCHD 3ACTIVATE PROGRAM 3**ACTIVATE DOWNLOAD 3DISPLY RF XMITTER STAT 1RELAY CONTROL 1

NOTES:* Minimum Level required to access function** Level-3 Code with appropriate user option*** Requires Dealer Code

Related User Options: Ambush Code� (Address 0495), �Panel Access Code� (Address 0490),�Dealer Security Code� (Address 0500) & �Enable User Code by Area� (Address 2500-2547).

USER OPTIONS

OPTIONS EXPLANATION

Disabled User Code not active in this area.

Blocked View Allows User Code to block another code from being viewed by another user.An unblocked code cannot view a blocked code, but a blocked code can viewall codes. The master user code and the dealer program code can view allcodes.

User Program User Program Option is enabled for Keypad 1 only, wherever it is connected(any area). If enabled, Level 3 must also be enabled.

Bypass Allows User Code to bypass zones.

Overview This option, along with Level 3 Authorization, enables selection of OVERVIEWmode at a keypad. This Mode provides a system status display of all areas at aglance.

Arm Only Prevents User Code from disarming this area.

Service A Service Code has restricted arm/disarm rights; if an area is armed with aService Code, a �SERVICE ON� appears on the GEM-RP2ASe2 keypad (a �S� onthe GEM-RP1CAe2 keypad) and the area can be disarmed with any valid UserCode, including a Service Code. If the area is armed with OTHER than aService Code, it CANNOT be disarmed with a Service Code. This is typicallyused to allow tradesmen access to premises under control of the owner.

Access This is normally used to activate a door striker while an area is disarmed. Acode with the access option will not function as an arm/disarm code. When thecode is entered, the keypad will display �ENTER NOW� and the Brown Wire onthe keypad will become Active Low (Ground Potential) for 7 seconds.

Page 27: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 27RF Transmitter Points (Press the (A) button to set cursor.)(For wireless systems only. Also see Quick Method, which follows)For each transmitter (key fob transmitters also), enter the zone number(01�48) to which the transmitter will be mapped, the 6-digit RF ID #:1-digitchecksum number printed on the transmitter and box, the point number(1�4); enter �9� for unsupervised (all points). NOTE: When programming theID Code number, �A� = G 0; �B� = G 1; �C� = G2; �D� = G 3; �E� = G 4; �F� = G 5. PressJto save. Press NEXT (E) button to proceed.

Quick Method. If a receiver is already installed in the panel, Napco transmitter wireless points can be programmedautomatically (�enrolled�) using the following procedure. NOTE: The transmitter point will be enrolled only if the signalstrength is 3 or greater.1. Enter the zone number to which the transmitter point will be mapped.

2. Press the B button to enter the Enroll Mode. The red and green LEDs on the keypad will flash and the window willdisplay as shown at left.

3. Open the loop of the point that is to be programmed (GEM-TRANS2 or GEM-TRANS4 only).

4. Install the transmitter battery. The keypad will beep to indicate that the point has been successfully enrolled. Multi-pointtransmitters can be mapped to successive zones simultaneously (Example 1) or to selected zones point by point(Example 2).Example 1. A 4-point transmitter has the RF ID number 410078:1. Map the first three points to Zones 11�13, respectively.1. Enter the Enroll mode as described in step 2 above.

2. Enter Zone �11�.

3. Open the loops of points 1, 2 and 3.

4. Install the transmitter battery. The keypad will beep 3 times to indicate that three points have been programmed.! Transmitter 410078:1, point 1 will be mapped to Zone 11.! Transmitter 410078:1, point 2 will be mapped to Zone 12.! Transmitter 410078:1, point 3 will be mapped to Zone 13.

The keypad will now display Zone 13, the last zone enrolled.

Example 2. A 2-point transmitter has the RF ID number 287613:1. Map point 1 to Zone 6 and point 2 to Zone 9.1. Enter the Enroll mode as described above.

2. Enter Zone �06�.

3. Open point-1 loop.

4. Install the battery. The keypad will beep once to indicate that one point has been programmed. (Transmitter 287613:1,point 1 will be mapped to Zone 6.)

5. Enter Zone �09�.

6. Close point-1 loop and open point-2 loop.

7. Remove the transmitter battery, then re-install it. The keypad will beep once to indicate that one point has beenprogrammed. (Transmitter 287613:1, point 2 is mapped to Zone 9.)

KEY FOB ZONE ASSIGNMENT: Key fobs can also be assigned to zones to allow multiple wireless panic buttons on onealarm system, each reporting to a central station, a pager or having a description on the keypad that describes the personholding the key fob, the location where the person holding the key fob is stationed, or the special purpose of the key fobbutton being depressed. See the next page on Key fob Zone Assignment.

GEM

-RP3D

GTL K

eypad: RF Transm

itter Points

(Direct Entry)

15 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

Page 28: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 28Key Fob Transmitters (Press the (A) button to set cursor.)Keyfobs can be programmed as �Arm/Disarm� devices. (refer to WI752).For each Key Fob Transmitter, enter:! the Key Fob Transmitter number (01�08).! area number to which transmitter is assigned (1 or 2); enter 0 to disable keyfob.! the 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters,including leading �0�s, if any).! 1-digit checksum number printed on the transmitter (enter all numbers and/orletters, including leading �0�s, if any).

! Aux-1 Option (see key fob aux 1 & aux 2 options).! Aux-2 Option (see key fob aux 1 & aux 2 options).Note: If the Key Fob is converted for Two Button�Emergency Use� (by cutting an internal jumper),both top or bottom buttons must be depressed to activate an alarm. In this case, the Aux-1and Aux-2 cannot be programmed. Press Jto save. Press NEXT (E) button toproceed.

Key Fob Zone Assignment (refer to display as shown on the previous page: press the(F) button to go backwards.) Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1;Off button = point 2; A1 = point 3; A2 = point 4. Up to 48 key fobs (using 1 button) or 24 keyfobs (using 2 buttons) or 14 key fobs (using all 4 buttons) or any combination up to amaximum of 48 controlled zones can be assigned, providing multiple wireless panic buttonson a system, each reporting to the Central Station or a pager and/or annunciating on akeypad the key fob zone number with description/location. To assign a key fob to a zone:program the key fob as you would a transmitter, entering the key fob's ID code, check sumand point number at the appropriate zone. The �Quick Method� is not allowed. The zonemay be hardwired to a sensor as well as assigned to a key fob (either one will activate thezone alarm output). NOTE: If assigning a key fob to a zone, the �ON/OFF� buttons on thekey fob will no longer arm/disarm the system. The key fob is converted to a �panic only�device.

Dealer CodeDirectly enter the Dealer Code, including leading zeros. Use the 1through 9 buttons. NOTE: Press the 0 button for a zero. PressJto save.

Re-enter the Dealer Code to verify the previous code. Press Jto save.Press NEXT (E) button to proceed.NOTE: The Dealer Code can be two or more digits (up to 6 digits).

CLEAR PROGRAM: Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode,press the C button to enter the Address Program Mode; (b) access Location 4091 (Clear Program) or 4093 (ColdStart); (c) press Jand then (d) press the C button to exit the Dealer Program Mode. A System Trouble Condition willoccur. Press the C button to silence the keypad.

NOTE: Key fobs 1-8 report openings andclosings as Users 25-32.

GEM

-RP3

DG

TL K

eypa

d: K

eyfo

b Tr

ansm

itter

s &

Dea

ler C

ode

(Direct Entry)

16 INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

DATAENTRY

AUX 1/AUX 2OPTIONS

0 None1 Relay Group 1 Toggle2 Relay Group 2 Toggle9 PanicA AuxiliaryB InstantC Aux. Output ToggleD Access on Aux.

Output

(Direct Entry)

17INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

rE INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the C button to enter theDirect Address Program Mode for further programming or press the C button once again to end all programmingand resume normal keypad operation.

Page 29: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 29A

ccessing Direct A

ddress Program M

ode

This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the KeypadProgramming Worksheets that follow. Refer to these worksheets to identify the 4-digit location (address) of the feature tobe programmed. An illustrative example is provided on the next page.

KEYPAD PROGRAMMING OVERVIEWDirect Address Programming allows you to go directly to the addresslocations and change the data entries to customize your control paneloptions. Whereas the Easy Menu Program Mode is a simple quickstart guide with limited options, the Direct Address Program Mode ismore flexible allowing you to change all the options.It consists of multiple address locations (up to 4093) with two dataentry locations each (left and right) as shown in the adjacent diagram.

ACCESSING DIRECT ADDRESS PROGRAM MODE

DATA ENTRYLOCATIONS

LEFT DIGIT RIGHT DIGIT3 C

ADDRESSLOCATIONS

0000

0000TO

4093

HEXADECIMAL DATA:BLANK (�) = No Options1 to 9 = Entries 1 to 90 = Entry of 10B to F = Entries 11 to 15

1. Press EEEEEE A

2. Press g Until �ACTIVATE PROGRAM Y/N� (GEM-RP1CAe2),�TURNON PROG Y/N� (GEM-RP2ASe2) or �17� (GEM-RP3DGTL) appears on the keypad display.

3. Press F To Enter Dealer Program Mode

4. Press C To Exit Easy Menu Driven Program Mode& Enter Direct Address Program Mode

Master Security Code(printed on microprocessor can)

orDealer Security Code (Address 0500)

DIRECT ADDRESS PROGRAM MODER

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

# OF ZONES IN AREA 1ENTER # ZONES X XAI #ZN=08 #KP=1���������������A2 #ZN=00 #KP=0

Page 30: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 30

KEYPAD ADDRESS PROGRAM MODE DISPLAY

DIRECT ADDRESS PROGRAM MODE KEYPAD COMMANDSA. GEM-RP1CAe2 Keypads

GEM-RP2ASe2 Keypad

00003CGEM-RP1CAe2 Keypad

0 0 0 0 3 C ( S E C O N D S )E X I T T I M E D L Y

1 2 1 2

= ADDRESS LOCATION1 2 = DATA ENTRY LOCATION (Left and Right Digits)

Acc

essi

ng D

irect

Add

ress

Pro

gram

Mod

e

(Direct Entry)

3P INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

3C INTERIOR BYPASS SYS TBL CHIMEFIRE/TBL

1

2

GEM-RP3DGTL Keypad

Press the A followed by 4 digitaddress location. NOTE: The addresslocation will flash rapidly and thendisappear with the corresponding data

Flashing

0000 3C0 0 0 0 3 C ( S E C O N D S )

Page 31: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 31

B. GEM-RP2ASe2 Keypad

C. GEM-RP3DGTL Keypad

Direct A

ddress Program M

ode: Keypad C

omm

ands

Flashing

To access, press the C button inthe Easy Menu Mode.

1. Press the A button.

2. Enter the 4 digit Address location directly using number buttons (0-9).

3. Enter the 2 digit data directly using number buttons (0-9).

4. Press the Jbutton to save.

To exit, press the C button

NOTE: �A� = G 0; �B� = G 1; �C� = G 2; �D� = G 3; �E� = G 4; �F� =G 5. Press 0 for a zero or to clear.

R

COMPUTERIZED SECURITY SYSTEM

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

GEMINI

ENT A1 3CINTERIOR BYPASS FIRE/TBL SYS TBL CHIME

Page 32: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 32The displays shown on the previous page will appear after a brief delay.! Use the the A button to toggle the cursor between the 4-digit address field and the data entry locations.

! Enter the address directly using the number buttons.! The contents of the address will be read automatically, along with the feature name and programming information.

The cursor will advance to the data field. Enter the required data directly using the number buttons.

! Press Jto save the contents of each address.

PROGRAMMING OVERVIEWThe Keypad Programming Worksheets in the back areprovided as an address-programming reference to helpthe installer modify his custom default program or to makeminor field alterations to an existing panel program. It isrecommended that the panel be uploaded to NAPCO'sQuickloader software following any keypad programmingand that the PCD3000's error-check feature be utilized toreduce the possibility of programming omissions orconflicts.Note: Most of the addresses shown comprise two dataentry locations, left and right digits. Program the left digitson the left data-display segment, and the right digit on theright segment. For those addresses having only oneprogrammable nibble, program the right segment only; theleft segment should display a blank (�).Keep the Keypad Programming Worksheets on file forfuture reference.

General Programming Steps! 1. Contact the central station to ascertain receiver

format, data format, event codes, subscriber numbersand telephone number(s).

! 2. Select the desired features by circling " therespective �address� boxes. Refer to the ProgrammingOptions and Worksheets for guidance in selecting the�data� (1,2,4,8) to be entered into those boxes.

! 3. Program the data entered in the boxes on theworksheets into the respective addresses. The displaywill show the entry numerically, but will display �0� for thenumber 10, and letters �B�, �C�, �D�, �E�, and �F� for thenumbers 11 through 15, respectively. To program a 10,press G 0. To program 11 through 15, pressG 1 through G 5, respectively.

NOTE: See the Direct Address Programming Example on the following page.

EXIT DIRECT ADDRESS PROGRAM MODE: When done, press the C button to exit and resume normal keypadoperation.

DATA ENTRY SELECTIONS

(BINARY VALUE CIRCLED) "ENTRYTOTAL

PRESSN KEYPADDISPLAYS

8 4 2 1 blank 0 �8 4 2 ! 1 1 1

8 4 " 1 2 2 2

8 4 " ! 3 3 3

8 # 2 1 4 4 4

8 # 2!

5 5 5

8 # " 1 6 6 6

8 # " ! 7 7 7

$ 4 2 1 8 8 8

$ 4 2 ! 9 9 9

$ 4 " 1 10 G 0 0

$ 4 " ! 11 G 1 B

$ # 2 1 12 G 2 C

$ # 2 ! 13 G 3 D

$ # " 1 14 G 4 E

$ # " ! 15 G 5 F

Table 1. Determining data entry for a location (each�nibble�). Numbers in parentheses indicate data forselected zones or features. (See ProgrammingWorksheets that follow.)

Dire

ct A

ddre

ss P

rogr

am M

ode:

Pro

gram

Ove

rvie

w &

Gen

eral

Pro

gram

min

g St

eps

Page 33: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 33

Direct Address Programming ExampleExample: Program Zones 6, 7 and 8 as Exit/Entry Follower Zones.

DETERMINE THE DATA ENTRIES! 1. Referring to ZONE FEATURES in the Programming Worksheets that follow, Exit/Entry Follower for Zones 5

through 8 are located at address 1218, left digit. Circle " the data values for Zones 5�8.! 2. Add the data values for Zones 6, 7 and 8: 2+4+8=14. From Tables 1 and 2, �14� (E) is entered as press G4. The right digit (for Zones 1 through 4, none of which are Exit/Entry Follower Zones) is entered as a

blank (�).

PROGRAM THE DATA ENTRIES! 1. Enter the panel's Dealer Security Code (Address 0500), then press the A button.

! 2. Answer NO (F) to all questions until �ACTIVATE PROGRAM Y/N� is displayed; then press YES (E). NOTE: If you pass �ACTIVATE PROGRAM�, scroll backward using the the B button.

! 3. Press the C button to enter the Address Program Mode. Address "0000" will display.

! 4. Press 1 2 1 8 to access Address 1218. The data for both digits will display and the cursor will advance to the data field.

! 5. Press G 4 to enter an �E� in the left digit and press 0 to enter a blank (�) in the right digit.

! 6. Press Jto save.

ZONE OPTION

EXIT/ENTRY FOLLOWER

ZONESLEFT DATA VALUES

SUM = 14 (CIRCLE ")ZN08 ZN07 ZN06 ZN05

$ # "1

ADDRESS1218

L ADDR RE 1218 blank (�)

ZONESRIGHT DATA VALUES

SUM = 0 (CIRCLE ")ZN04 ZN03 ZN02 ZN01

8 4 2 1

ENTER DATA "

Direct A

ddress Program M

ode: Programm

ing Example

Page 34: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 34

PROGRAMMING OPTIONS & WORKSHEETSR

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

# OF ZONES IN AREA 1ENTER # ZONES X XAI #ZN=08 #KP=1���������������A2 #ZN=00 #KP=0

1. Press EEEEEE A

2. Press g Until �ACTIVATE PROGRAM Y/N� (GEM-RP1CAe2) or�TURNON PROG Y/N� (GEM-RP2ASe2)appears on LCD

screen or Function �17� (GEM-RP3DGTL).

3. Press F To Enter Dealer Program Mode

4. Press C To Exit Easy Menu Driven Program Mode& Enter Direct Address Program Mode

Dealer Code (Address 0500)

Determining data entry for a location (each �nibble�).Numbers in parentheses indicate data for selectedzones or features. (See Programming Worksheetsthat follow.)

DEFAULTS: The defaults shown on the following pages are automatically set after exiting the Easy Menu Driven Mode.

ENTER DATA "

ADDRESS LOC.LEFT RIGHTProgram

Option

PROGRAMMING STEPS:1. Lookup desired Programming Option byAddress Location (highlighted in black).

2. Select the programming option data entryfrom the tables shown, by direct entry or byadding binary values.

3. Enter the selected data entry in the boxesshown.

4. For more information on a programmingoption refer to the Glossary at the end of thismanual.

ENTRYTOTAL

PRESSN KEYPADDISPLAYS

blank 0 �1 1 1

2 2 2

3 3 3

4 4 4

5 5 5

6 6 6

7 7 7

8 8 8

9 9 9

10 G 0 0

11 G 1 B

12 G 2 C

13 G 3 D

14 G 4 E

15 G 5 F

Dire

ct A

ddre

ss P

rogr

am M

ode:

Pro

gram

min

g O

ptio

ns &

Wor

kshe

ets

Page 35: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 35

SYSTEM DELAYS & TIMEOUTS (ADDRESS 0000-0002, 2402, 2406, 2414 & 3902)

ADDRESS 0000LEFT RIGHT

EXITDELAY(sec.)

[Default = 3C]

ADDRESS 0001LEFT RIGHT

ENTRYDELAY 1

(sec.)

[Default = 1E]

ADDRESS 0002LEFT RIGHT

ENTRYDELAY 2

(sec.)

[Default = 1 E]

PROGRAMMING TIMEOUTS: Either use the tables provide or calculate your own timeout using the steps indicated.WARNING: Timers have uncertainty of +/-1sec, so a "time" of 1 second may actually timeout IMMEDIATELY.

ADDRESS 2406LEFT RIGHT

ABORTDELAY(sec.)

[Default = blank (�) blank (�)]

DATA ENTRIESLEFT RIGHT

blank (�) blank (�)blank (�) F

1 E2 D3 C5 07 8

F F

DELAY/TIMEOUT

0 sec.15 sec.30 sec.45 sec.60 sec.90 sec.

120 sec.

255 sec.

! 1. Select delay/timeout (0-255 sec.) from the table shown.! 2. Enter in corresponding address locations above (left and right digits).! 3. For a desired delay/timeout not listed do the following:

A. Choose a desired delay/timeout, ex: 20 sec.

B. Divide it by 16

EXIT/ENTRY DELAYS: Apply only to zones programmed with the followingoptions �Entry/Exit 1, Entry/Exit 2, Exit/Entry Follower�. For UL Installations, the maximum exitdelay is 60 seconds and the maximum entry delay is 45 seconds.

SYSTEM DELAYS & TIMEOUTS (ADDRESS 2407, 2408 & 4088)

ADDRESS 2407LEFT RIGHT

CHIMETIMEOUT(¼sec.)

[Default = blank (�) 2]

DATA ENTRIESLEFT RIGHT

blank (�) blank (�)blank (�) 2blank (�) 3blank (�) 4blank (�) 5blank (�) 6blank (�) 7blank (�) 8

F F

TIMEOUT

0 ¼sec. = 0 sec. 2 ¼sec. = ½ sec.3 ¼sec. = ¾ sec. 4 ¼sec. = 1 sec.5 ¼sec. = 1.25 sec.6 ¼sec. = 1.5 sec.7 ¼sec. = 1.75 sec.

8 ¼sec. = 2 sec.

255 ¼sec. = 63.25 sec.

CHIME TIMEOUT OPTIONS

[Default = blank (�) blank (�)]

ADDRESS 2408LEFT RIGHT

AC FailReportDelay(min.)

DATA ENTRIESLEFT RIGHT

blank (�) blank (�)blank (�) 1blank (�) 2blank (�) 3blank (�) 4blank (�) 5blank (�) 6blank (�) 7

F F

DELAY

0 min.10 min.20 min.30 min.40 min.50 min.60 min.70 min.

2550 min. = 42 Hr., 30 min.

AC FAIL REPORT DELAY OPTIONS

! 1. Select delay/timeout from the table shown.! 2. Enter in corresponding address locations above (left and right digits).! 3. For a desired delay/timeout not listed do the following:

A. Choose a desired delay/timeout , ex: 20. Note: For Sensor Watch only divide it by 10, ex: 20/10 = 2

B. Divide it by 16 1 Quotient Left Digit16 20 16

4 Remainder Right Digit

[Default = blank (�) blank (�)]

ADDRESS 2402LEFT RIGHT

Aux. OutputAccessControlTimeout

(sec.)

[Default = blank (�) blank (�)]

ADDRESS 4088LEFT RIGHT

SensorWatchDelay(Hr.)

DATA ENTRIESLEFT RIGHT

blank (�) blank (�)blank (�) 1blank (�) 2blank (�) 3blank (�) 4blank (�) 5blank (�) 6blank (�) 7

F F

DELAY

0 Hr.1 Hr.2 Hr.3 Hr.4 Hr.5 Hr.6 Hr.7 Hr.

255 Hr.

SENSOR WATCH OPTIONS

[Default = blank (�) blank (�)]

ADDRESS 2414LEFT RIGHT

TelephoneLine Test

Delay(sec.)

System D

elays/Timeouts

[Default = blank (�) blank (�)]

ADDRESS 3902LEFT RIGHT

CS Telco 3ReportDelay(sec.)

1 Quotient Left Digit16 20 16

4 Remainder Right Digit

Page 36: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 36

SYSTEM DELAYS & TIMEOUTS (ADDRESS 2400, 2401, 2403-2405, 4082 & 4083)

DATA ENTRIESLEFT RIGHT

blank (�) blank (�)blank (�) 1blank (�) 2blank (�) 3blank (�) 4blank (�) 5blank (�) 6

1 blank (�)

F F

DELAY/TIMEOUT

0 min.1 min.2 min.3 min.4 min.5 min.6 min.

16 min.

255 min.

[Default = blank (�) blank (�)]

ADDRESS 2400LEFT RIGHT

ResetOutput

Timeout(min.)

[Default = blank (�) blank (�) ]

ADDRESS 2401LEFT RIGHT

Aux.Output

Timeout(min.)

[Default = 1 blank (�)]

ADDRESS 2403LEFT RIGHT

Burg.AlarmOutput

Timeout(min.)

! 1. Select delay/timeout (0-255 min.) from the table shown.! 2. Enter in corresponding address locations above (left and right digits).! 3. For a desired delay/timeout not listed do the following:

A. Choose a desired delay/timeout, ex: 20 min.

B. Divide it by 16

OUTPUT TIMEOUTS: If a timeout of �0 min.� is selected, then the outputwill remain active (ON) until the system is reset or disarmed. For UL Residential Installations, theminimum timeout is 4 minutes. For UL Commercial Installations, the minimum timeout is 15minutes.

[Default = blank (�) 1]

ADDRESS 2404LEFT RIGHT

PulseAlarmOutput

Timeout(min.)

[Default = blank (�) blank (�) ]

ADDRESS 2405LEFT RIGHT

FireOutput

Timeout(min.)

[Default = blank (�) blank (�)]

ADDRESS 4083LEFT RIGHT

AutoDisarmRearmDelay(min.)

KEYPAD SYSTEM CODES (ADDRESS 0490, 0495 & 0500)

DEALER SECURITY CODE: Enter up to 6 digits to be used by the dealer to enter programming.! 1. Enter in both left and right digits of address locations.! 2. Valid entries are: 0-9.Note: If left blank, the Master Security Code must then be used to enter programming.

AMBUSH CODE: Enter a 2-digit code used just prior to disarming and will activate an Ambush Condition, causing a SILENT report tobe sent to the central station.! 1. Enter in both left and right digits of address locations.! 2. Valid entries are: 0-9.Note: Also, �Enable Keypad Ambush� (Address 2440-2446), �Report on Ambush Alarm� (Address 1125, 1127, 1135 & 1137) and�Ambush Code� (Address 0900) must all be enabled.

[Default = blank (�) blank (�) from address 0490-0492]

Panel AccessCode

ADDRESS 0490-04920490 0491 0492

L R L R L R

PANEL ACCESS CODE: Enter up to 6 digits to activate a door strike while the area is disarmed.! 1. Enter in both left and right digits of address locations.! 2. Valid entries are: 0-9.Note: Also, �Access Control on Aux. Output� (Address 2418) and �Aux. Output Access Control Timeout� (Address 2402) must both beenabled.

ADDRESS 0495LEFT RIGHTAmbush

Code

[Default = blank (�) blank (�)]

[Default = blank (�) blank (�) from address 0500-0502]

Dealer SecurityCode

ADDRESS 0500-05020500 0501 0502

L R L R L R

Syst

em D

elay

s/Ti

meo

uts

& K

eypa

d C

odes

[Default = blank (�) blank (�)]

ADDRESS 4082LEFT RIGHT

ReportCancel

Window(sec.)

1 Quotient Left Digit16 20 16

4 Remainder Right Digit

Page 37: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 37

Default for CS Receiver 1 Format depends on Easy Menu Question �RCVR FORMAT�. [Default = �(blank) �(blank)] for CS Receivers 2 and 3 Formats.

CS RECEIVER FORMAT OPTIONS (ADDRESS 0520, 0521, 0525, 0526, 0550, 0551, 0575 & 0576)

ADDRESS 0525LEFT RIGHTCS Receiver 1

Format

CS RECEIVER FORMATS: Up to 3 CS Formats may be programmed.! 1. Select the desired CS Receiver Format from the table shown.! 2. Enter in the corresponding left and right digit address locations for

each CS Receiver. NOTE: Dark shaded data value box shows option not available.

ADDRESS 0550LEFT RIGHTCS Receiver 2

Format

ADDRESS 0575LEFT RIGHTCS Receiver 3

Format

[Default = blank (�) blank (�)]

[Default = blank (�) blank (�)]

[Default = blank (�) blank (�)]

ADDRESS 0526

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

RIGHT DATAVALUES

(CIRCLE ")1248

CS RECEIVER 1 OPTIONS

1400Hz Handshake/Kissoff *2300Hz Handshake/Kissoff *

Enable Zone Number on Pulse AlarmSingle Digit Only

LEFT DATAVALUES

(CIRCLE ")1248

CS RECEIVER 1 OPTIONS

Sum Check3/1 with Extended Restores

RESERVEDRESERVED

CS RECEIVER OPTIONS: Select options for any of the three CS Receivers.! 1. Select the desired option by circling " the data values for each digit (left and right).

! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in address location (left and right digits).NOTE: Dark shaded data value box shows option not available.

NOTE: * If both are selected, 1400Hzhas priority over 2300Hz.

ADDRESS 0551

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

RIGHT DATAVALUES

(CIRCLE ")1248

CS RECEIVER 2 OPTIONS

1400Hz Handshake/Kissoff *2300Hz Handshake/Kissoff *

Enable Zone Number on Pulse AlarmSingle Digit Only

LEFT DATAVALUES

(CIRCLE ")1248

CS RECEIVER 2 OPTIONS

Sum Check3/1 with Extended Restores

RESERVEDRESERVED

ADDRESS 0576

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

RIGHT DATAVALUES

(CIRCLE ")1248

CS RECEIVER 3 OPTIONS

1400Hz Handshake/Kissoff *2300Hz Handshake/Kissoff *

Enable Zone Number on Pulse AlarmSingle Digit Only

LEFT DATAVALUES

(CIRCLE ")1248

CS RECEIVER 3 OPTIONS

Sum Check3/1 with Extended Restores

RESERVEDRESERVED

CS RECEIVER FORMATS

Ademco Slow, Silent Knight SlowSescoa, Vertex, DCI, Franklin Fast

Radionics FastSilent Knight Fast

Radionics, DCI, Franklin SlowUniversal High Speed

Radionics BFSKFBI 4/3/1

Radionics Modem 2SIA

Ademco Point IDAdemco Express

PagerRadionics Modem IIe

DATA ENTRIESLEFT RIGHT

blank (�) blank (�)blank (�) 1blank (�) 2blank (�) 3blank (�) 4blank (�) 5blank (�) 8blank (�) 9blank (�) 0blank (�) Bblank (�) Cblank (�) Dblank (�) E

1 blank (�)

LEADING DIGITS FOR PAGER FORMAT: In Pager Format reporting, the message typically begins with �00�. However, for somepager services, this will cause the Pager's Voice Mail feature to activate. This option allows you to program these digits to any numberdesired. Typical Pager report is �003 022 1234�, where 3 is the Event, 22 is the zone, and 1234 is the Subscriber ID number. Forexample, if the Leading Digits are programmed as �98�, the Pager report will now appear as �983 022 1234�.! 1. Enter in 1st and 2nd Leading Digits in right digit only (left digit is not used) as shown.! 2. Valid entries are: 0-9.

[Default = blank (�) blank (�)]

Leading Digits forPager Format

(1st Digit)

ADDRESS 0520LEFT RIGHT

blank (�)

[Default = blank (�) blank (�)]

Leading Digits forPager Format

(2nd Digit)

ADDRESS 0521LEFT RIGHT

blank (�)

CS R

eceiver Format O

ptions

Page 38: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 38

CS Receiver1 Telephone

Number(Digits 1-20)

ADDRESS 0527-0546 (RIGHT DIGITS 1-20)0527 0528 0529 0530 0531 0532 0533 0534 0535 0536 0537 0538 0539 0540 0541 0542 0543 0544 0545 0546

R R R R R R R R R R R R R R R R R R R R

CS Receiver2 Telephone

Number(Digits 1-20)

ADDRESS 0552-0571 (RIGHT DIGITS 1-20)0552 0553 0554 0555 0556 0557 0558 0559 0560 0561 0562 0563 0564 0565 0566 0567 0568 0569 0570 0571

R R R R R R R R R R R R R R R R R R R R

CS Receiver3 Telephone

Number(Digits 1-20)

ADDRESS 0577-0596 (RIGHT DIGITS 1-20)0577 0578 0579 0580 0581 0582 0583 0584 0585 0586 0587 0588 0589 0590 0591 0592 0593 0594 0595 0596

R R R R R R R R R R R R R R R R R R R R

CS RECEIVER TELEPHONE NUMBERS: Enter telephone numbers for any of the three CS Receivers (Telco 1, 2 & 3).! 1. Enter in right digit only (left digit is not used).! 2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (�).

! 3. Valid entries are: 1-9, B = *button, C = #button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location

Default for CSReceiver 1Telephone Numberdepends on EasyMenu Question�CENTRAL PHONE#�.

[Default = blank (�)]across digits 1-20 forCS ReceiverTelephone Numbers2 and 3.

CS RECEIVER TELEPHONE NUMBERS (ADDRESS 0527-0546, 0552-0571, 0577-0596)

DOWNLOAD/CALLBACK OPTIONS (ADDRESS 4089, 0600-0619, 0625-0647, 1022 & 1023)

NUMBER OF RINGS BEFORE PICKUP: Enter the number of rings before automatic pickup by thecontrol panel when downloading from a computer (see Glossary at the back for more information).! 1. Enter in right digit only (left digit is not used).! 2. Valid entries are: 1-9, 0 = 10, B = 11, C = 12, D = 13, E = 14, F = 15

NOTE: Default is 15 Rings. Dark shaded data shows option not available.

CALLBACK TELEPHONE NUMBERS: Enter telephone numbers to be used when downloading from a computer.! 1. Enter in right digit only (left digit is not used).! 2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (�).

! 3. Valid entries are: 0-9, B = *button, C = #button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location

ADDRESS 4089LEFT RIGHT

blank (�)

No. RingsBeforePickup

[Default = blank (�) F]

[Default = blank (�) for all digits 1-20]

ADDRESS 0600-0619 (RIGHT DIGITS 1-20)0600 0601 0602 0603 0604 0605 0606 0607 0608 0609 0610 0611 0612 0613 0614 0615 0616 0617 0618 0619

R R R R R R R R R R R R R R R R R R R R

CallbackTelephoneNumber 1

(Digits 1-20)

[Default = blank (�) for all digits 1-20]

ADDRESS 0625-0644 (RIGHT DIGITS 1-20)0625 0626 0627 0628 0629 0630 0631 0632 0633 0634 0635 0636 0637 0638 0639 0640 0641 0642 0643 0644

R R R R R R R R R R R R R R R R R R R R

CallbackTelephoneNumber 2

(Digits 1-20)

[Default = blank (�) blank (�)]

DownloadSecurity Code

ADDRESS 0645-06470645 0646 0647

L R L R L R

DOWNLOAD SECURITY CODE: Enter up to 6 digits to be usedfor remote access when downloading from a computer.! 1. Enter in both left and right digits of address locations.

! 2. Valid entries are: 0-9.Note: Download Security Code must match the code entered inthe PCD3000 Software.

ADDRESS 1022LEFT RIGHT

blank (�)

CallbackTelephoneNo. Select

[Default = blank (�) blank (�)]

CALLBACK TELEPHONE NO. SELECT: Enter either �1�for Callback Telephone Number 1 or �2� for CallbackTelephone Number 2.! 1. Enter in right digit only (left digit is not used).

! 2. Valid entries are: 1 or 2.

CS

Rec

eive

r Tel

epho

ne N

umbe

rs &

Dow

nloa

d/C

allb

ack

Opt

ions

ADDRESS 1023LEFT RIGHTAuto Download

ID No.

[Default = blank (�) blank (�)]

Valid entries - 01-99

Page 39: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 39

CS SUBSCRIBER ID NUMBERS (ADDRESS 0650-0787)C

S Subscriber ID N

umbers (TELC

O 1 &

2)

AREA 1ADDRESS 0650-0653(RIGHT DIGITS 1-4)

0650 0651 0652 0653R R R R

CS TELCO 1 SUBSCRIBER OPENING/CLOSING ID NUMBERS

AREA 2ADDRESS 0654-0657(RIGHT DIGITS 1-4)

0654 0655 0656 0657R R R R

AREA 1ADDRESS 0682-0685(RIGHT DIGITS 1-4)

0682 0683 0684 0685R R R R

CS TELCO 1 SUBSCRIBER EVENT ID NUMBERS

AREA 2ADDRESS 0686-0689(RIGHT DIGITS 1-4)

0686 0687 0688 0689R R R R

AREA 1ADDRESS 0720-0723(RIGHT DIGITS 1-4)

0720 0721 0722 0723R R R R

CS TELCO 2 SUBSCRIBER OPENING/CLOSING ID NUMBERS (BACKUP REPORTING)

AREA 2ADDRESS 0724-0727(RIGHT DIGITS 1-4)

0724 0725 0726 0727R R R R

AREA 1ADDRESS 0752-0755(RIGHT DIGITS 1-4)

0752 0753 0754 0755R R R R

CS TELCO 2 SUBSCRIBER EVENT ID NUMBERS (BACKUP REPORTING)

AREA 2ADDRESS 0756-0759(RIGHT DIGITS 1-4)

0756 0757 0758 0759R R R R

SYSTEMADDRESS 0784-0787(RIGHT DIGITS 1-4)

0784 0785 0786 0787R R R R

SYSTEMADDRESS 0714-0717(RIGHT DIGITS 1-4)

0714 0715 0716 0717R R R R

Page 40: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 40

CS REPORTING CODES (ADDRESS 0859-0869)ADDRESS0864-0869

LEFT ADDR RIGHTblank (�) 0864blank (�) 0865blank (�) 0866blank (�) 0867

08680869

OPENING/CLOSINGREPORTING CODES

ClosingConditional Closing

OpeningOpening after Alarm

Fail to CloseFail to Open

ADDRESS0860-0862

LEFT ADDR RIGHTblank (�) 0859blank (�) 0860blank (�) 0861blank (�) 0862

ALARM/TROUBLEREPORTING CODES

CancelAlarm Restore

TroubleTrouble Restore

[Default = blank (�) blank (�) from address 0859-0869]

CS REPORTING CODES:! 1. Enter in corresponding address

location (left and right digits).! 2. Valid entries are: 1-9, 0 and B-F.

NOTE: Dark shaded data value box shows option not available.

Default for CS Telco 1 Subscriber Event ID Number (Area 1) depends on Easy Menu Question �ACCOUNT #�. [Default = blank (�) blank (�) blank (�)blank (�)] for all other ID Numbers.CS TELCO SUBSCRIBER ID NUMBERS: Enter the Subscriber Opening/Closing and Event ID Numbers for any of the 3 CSReceivers.! 1. Enter in corresponding right digit address location (left digit is not used).! 2. Enter 3 or 4 digits (depending on the CS receiver format) for each subscriber number from left to right.

NOTE: Leave trailing boxes blank (�).! 3. Valid entries are: 0-9, 0 and B-F.

CS SUBSCRIBER ID NUMBERS (ADDRESS 0790-0857)

AREA 1ADDRESS 0790-0793(RIGHT DIGITS 1-4)

0790 0791 0792 0793R R R R

CS TELCO 3 SUBSCRIBER OPENING/CLOSING ID NUMBERS

AREA 2ADDRESS 0794-0797(RIGHT DIGITS 1-4)

0794 0795 0796 0797R R R R

AREA 1ADDRESS 0822-0825(RIGHT DIGITS 1-4)

0822 0823 0824 0825R R R R

CS TELCO 3 SUBSCRIBER EVENT ID NUMBERS

AREA 2ADDRESS 0826-0829(RIGHT DIGITS 1-4)

0826 0827 0828 0829R R R R

SYSTEMADDRESS 0854-0857(RIGHT DIGITS 1-4)

0854 0855 0856 0857R R R R

CS

Subs

crib

er ID

Num

bers

(TEL

CO

3) &

CS

Rep

ortin

g C

odes

Page 41: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 41

CS REPORTING CODES:! 1. Enter in corresponding address location (left and right digits).! 2. Valid entries are: 1-9, 0 and B-F.

NOTE: Dark shaded data value box shows option not available.

ADDRESS0870-0880

LEFT ADDR RIGHT08700871087208730874087508760877

blank (�) 0878 blank (�)blank (�) 0879 blank (�)

0880

SYSTEMREPORTING CODES

Test TimerAlarm Supervisory

Bus FailureMemory Failure

Panel Low BatteryPanel AC Failure

EZM TamperSensor Watch

RESERVEDRESERVED

Telco Line Failure

CS REPORTING CODES (ADDRESS 0870-0904)

[Default = blank (�) blank (�) from address 0870-0904]

ADDRESS0890-0897

LEFT ADDR RIGHT0890

blank (�) 0891 blank (�)blank (�) 0892 blank (�)

08930894089508960897

SYSTEMREPORTING CODES

Digital Dialer TestRESERVEDRESERVED

Service MessageProgram Change

RF Receiver TroubleRF Receiver Tamper

RF Trouble

ADDRESS0900-0904

LEFT ADDR RIGHT09000901090209030904

KEYPADREPORTING CODES

AmbushPanicFire

AuxiliaryTamper

CAUTION: For all 2-Digit Reporting Formats (see CS Receiver Format Options), use the following:

Example: The 2-digit reporting code as shown is �21�.

ADDRESS LOC.LEFT RIGHT

1 2

ReportingCode

2nd Digit of Reporting Code 1st Digit of Reporting Code

CS AREA & SYSTEM REPORTING OPTIONS (ADDRESS 1024-1027)

* NOTE: If neither TouchTone Dialing norTouchTone w/Rotary Backup is selected, thensystem defaults automatically to Rotary Dialing.Leave blank (�) to select Rotary Dialing.

CS AREA & SYSTEM REPORTING OPTIONS:! 1. Select the desired option by circling " the data values for each digit (left and

right).! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in address location (left and right digits).NOTE: Dark shaded data value box shows option not available.

[Default = blank (�) blank (�)]

ADDRESS 1027

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

LEFT DATAVALUES

(CIRCLE ")1248

CS SYSTEM REPORT OPTIONS

Cancel Next Test Timer on any ReportDisable Wait for Silence

Disable Wait for HandshakeHandshake for Local Telemetry

RIGHT DATAVALUES

(CIRCLE ")124

8

CS SYSTEM REPORT OPTIONS

Backup Report on Telco 2TouchTone Dialing Only *

TouchTone Dialing w/Rotary Backup *Transmit �402� Opening/Closing Code

CS R

eporting Codes &

CS R

eporting Options

[Default = blank (�) blank (�)]

DISABLE OPENINGREPORTS

ADDRESS 1024

LEFT DIGIT RIGHTDIGIT

blank (�)

LEFT DATAVALUES

(CIRCLE ")1248

AREA

Area 1Area 2RESVDRESVD

LEFT DATAVALUES

(CIRCLE ")124

8

AREA

RESVDRESVDRESVDRESVD [Default = blank (�) blank (�)]

DISABLE CLOSINGREPORTS

ADDRESS 1025

LEFT DIGIT RIGHTDIGIT

blank (�)

LEFT DATAVALUES

(CIRCLE ")1248

AREA

Area 1Area 2RESVDRESVD

LEFT DATAVALUES

(CIRCLE ")124

8

AREA

RESVDRESVDRESVDRESVD

Page 42: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 42

ADDRESS 0910-0917ZONES REPORT CODE (CONTROL PANEL)

ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 80910 0911 0912 0913 0914 0915 0916 0917

L R L R L R L R L R L R L R L R

ADDRESS 0918-0921ZONES REPORT CODE (GROUP 1)ZONE 9 ZONE 10 ZONE 11 ZONE 12

0918 0919 0920 0921L R L R L R L R

ADDRESS 0922-0925ZONES REPORT CODE (GROUP 2)

ZONE 13 ZONE 14 ZONE 15 ZONE 160922 0923 0924 0925

L R L R L R L R

ADDRESS 0934-0937ZONES REPORT CODE (GROUP 5)

ZONE 25 ZONE 26 ZONE 27 ZONE 280934 0935 0936 0937

L R L R L R L R

ADDRESS 0938-0941ZONES REPORT CODE (GROUP 6)

ZONE 29 ZONE 30 ZONE 31 ZONE 320938 0939 0940 0941

L R L R L R L R

ADDRESS 0926-0929ZONES REPORT CODE (GROUP 3)

ZONE 17 ZONE 18 ZONE 19 ZONE 200926 0927 0928 0929

L R L R L R L R

ADDRESS 0930-0933ZONES REPORT CODE (GROUP 4)

ZONE 21 ZONE 22 ZONE 23 ZONE 240930 0931 0932 0933

L R L R L R L R

Default for Group Zone Report Codes depends on Easy Menu Question �RCVR.

7 Gas Alarm8 Heat Alarm0 Auxiliary AlarmB 24 Hour Auxiliary

DATAENTRIES

LEFT1234

MODEM CODE

Fire *Panic

BurglaryHold up

ZONE REPORTCODE OPTIONSDATA ENTRIESLEFT RIGHT

NOTE: Zones 1-8 are included in the control panel and Zones 9-48 are EZM Zones. See Address 2600-2605 toenable �EZM Zone Groups�.

PULSE EVENT CODE will be the first digit of the 2 digit reporting code. the second digit will be thesecond digit of the reporting zone. For example, for zone 9 (address 0918), if the right digit is �3", thenthe reporting code is �39�. For example, for zone 15 (address 0924), if the right digit is �4", then thereporting code is �45�.

MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO PointID.! 1. Select the desired Modem Code for each zone from the table shown.

CS ZONE REPORTING CODES (ADDRESS 0910-0957)

ADDRESS 0950-0953ZONES REPORT CODE (GROUP 9)

ZONE 41 ZONE 42 ZONE 43 ZONE 440950 0951 0952 0953

L R L R L R L R

ADDRESS 0954-0957ZONES REPORT CODE (GROUP 10)ZONE 45 ZONE 46 ZONE 47 ZONE 48

0954 0955 0956 0957L R L R L R L R

ADDRESS 0942-0945ZONES REPORT CODE (GROUP 7)

ZONE 33 ZONE 34 ZONE 35 ZONE 360942 0943 0944 0945

L R L R L R L R

ADDRESS 0946-0949ZONES REPORT CODE (GROUP 8)

ZONE 37 ZONE 38 ZONE 39 ZONE 400946 0947 0948 0949

L R L R L R L R

CS

Zone

Rep

ortin

g C

odes

Page 43: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 43

CS USER REPORTING CODES (ADDRESS 1030-1055)

User OpeningTelco 1

ADDRESS 1042

LEFT RIGHT

blank (�)

RIGHT DATA VALUESUser00

User99

User98

User97

8 4 2 1

User 97 = Auto Arming/DisarmingUser 98 = Quickloader Arming/DisarmingUser 99 = Easy Arming (Opening not applicable)User 00 = Keyswitch Arming

NOTE: These opening events will reportas the user number shown. Also, Keyfobs1-8 (see Easy Menu Program DrivenMode) will report as Users 25-32,respectively.

User OpeningTelco 1

LEFT DATA VALUESUser16

User15

User14

User13

8 4 2 1

ADDRESS 1031

LEFT RIGHT

RIGHT DATA VALUESUser12

User11

User10

User9

8 4 2 1

LEFT DATA VALUESUser

8User

7User

6User

58 4 2 1

ADDRESS 1030

LEFT RIGHT

RIGHT DATA VALUESUser

4User

3User

2User

18 4 2 1

User OpeningTelco 1

LEFT DATA VALUESUser32

User31

User30

User29

8 4 2 1

ADDRESS 1033

LEFT RIGHT

RIGHT DATA VALUESUser28

User27

User26

User25

8 4 2 1

LEFT DATA VALUESUser24

User23

User22

User21

8 4 2 1

ADDRESS 1032

LEFT RIGHT

RIGHT DATA VALUESUser20

User19

User18

User17

8 4 2 1

User OpeningTelco 1

LEFT DATA VALUESUser48

User47

User46

User45

8 4 2 1

ADDRESS 1035

LEFT RIGHT

RIGHT DATA VALUESUser44

User43

User42

User41

8 4 2 1

LEFT DATA VALUESUser40

User39

User38

User37

8 4 2 1

ADDRESS 1034

LEFT RIGHT

RIGHT DATA VALUESUser36

User35

User34

User33

8 4 2 1

User ClosingTelco 1

ADDRESS 1055

LEFT RIGHT

blank (�)

RIGHT DATA VALUESUser00

User99

User98

User97

8 4 2 1

User 97 = Auto Arming/DisarmingUser 98 = Quickloader Arming/DisarmingUser 99 = Easy Arming (Opening not applicable)User 00 = Keyswitch Arming

NOTE: These opening events will reportas the user number shown. Also, Keyfobs1-8 (see Easy Menu Program DrivenMode) will report as Users 25-32,respectively.

User ClosingTelco 1

LEFT DATA VALUESUser16

User15

User14

User13

8 4 2 1

ADDRESS 1044

LEFT RIGHT

RIGHT DATA VALUESUser12

User11

User10

User9

8 4 2 1

LEFT DATA VALUESUser

8User

7User

6User

58 4 2 1

ADDRESS 1043

LEFT RIGHT

RIGHT DATA VALUESUser

4User

3User

2User

18 4 2 1

User ClosingTelco 1

LEFT DATA VALUESUser32

User31

User30

User29

8 4 2 1

ADDRESS 1046

LEFT RIGHT

RIGHT DATA VALUESUser28

User27

User26

User25

8 4 2 1

LEFT DATA VALUESUser24

User23

User22

User21

8 4 2 1

ADDRESS 1045

LEFT RIGHT

RIGHT DATA VALUESUser20

User19

User18

User17

8 4 2 1

User ClosingTelco 1

LEFT DATA VALUESUser48

User47

User46

User45

8 4 2 1

ADDRESS 1048

LEFT RIGHT

RIGHT DATA VALUESUser44

User43

User42

User41

8 4 2 1

LEFT DATA VALUESUser40

User39

User38

User37

8 4 2 1

ADDRESS 1047

LEFT RIGHT

RIGHT DATA VALUESUser36

User35

User34

User33

8 4 2 1

CS U

ser Reporting C

odes

Page 44: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 44

CS USER REPORTING CODES (ADDRESS 1056-1081)

User OpeningTelco 3

ADDRESS 1068

LEFT RIGHT

blank (�)

RIGHT DATA VALUESUser00

User99

User98

User97

8 4 2 1

User 97 = Auto Arming/DisarmingUser 98 = Quickloader Arming/DisarmingUser 99 = Easy Arming (Opening not applicable)User 00 = Keyswitch Arming

NOTE: These opening events will reportas the user number shown. Also, Keyfobs1-8 (see Easy Menu Program DrivenMode) will report as Users 25-32,respectively.

User OpeningTelco 3

LEFT DATA VALUESUser16

User15

User14

User13

8 4 2 1

ADDRESS 1057

LEFT RIGHT

RIGHT DATA VALUESUser12

User11

User10

User9

8 4 2 1

LEFT DATA VALUESUser

8User

7User

6User

58 4 2 1

ADDRESS 1056

LEFT RIGHT

RIGHT DATA VALUESUser

4User

3User

2User

18 4 2 1

User OpeningTelco 3

LEFT DATA VALUESUser32

User31

User30

User29

8 4 2 1

ADDRESS 1059

LEFT RIGHT

RIGHT DATA VALUESUser28

User27

User26

User25

8 4 2 1

LEFT DATA VALUESUser24

User23

User22

User21

8 4 2 1

ADDRESS 1058

LEFT RIGHT

RIGHT DATA VALUESUser20

User19

User18

User17

8 4 2 1

User OpeningTelco 3

LEFT DATA VALUESUser48

User47

User46

User45

8 4 2 1

ADDRESS 1061

LEFT RIGHT

RIGHT DATA VALUESUser44

User43

User42

User41

8 4 2 1

LEFT DATA VALUESUser40

User39

User38

User37

8 4 2 1

ADDRESS 1060

LEFT RIGHT

RIGHT DATA VALUESUser36

User35

User34

User33

8 4 2 1

User ClosingTelco 3

ADDRESS 1081

LEFT RIGHT

blank (�)

RIGHT DATA VALUESUser00

User99

User98

User97

8 4 2 1

User 97 = Auto Arming/DisarmingUser 98 = Quickloader Arming/DisarmingUser 99 = Easy Arming (Opening not applicable)User 00 = Keyswitch Arming

NOTE: These opening events will reportas the user number shown. Also, Keyfobs1-8 (see Easy Menu Program DrivenMode) will report as Users 25-32,respectively.

User ClosingTelco 3

LEFT DATA VALUESUser16

User15

User14

User13

8 4 2 1

ADDRESS 1070

LEFT RIGHT

RIGHT DATA VALUESUser12

User11

User10

User9

8 4 2 1

LEFT DATA VALUESUser

8User

7User

6User

58 4 2 1

ADDRESS 1069

LEFT RIGHT

RIGHT DATA VALUESUser

4User

3User

2User

18 4 2 1

User ClosingTelco 3

LEFT DATA VALUESUser32

User31

User30

User29

8 4 2 1

ADDRESS 1072

LEFT RIGHT

RIGHT DATA VALUESUser28

User27

User26

User25

8 4 2 1

LEFT DATA VALUESUser24

User23

User22

User21

8 4 2 1

ADDRESS 1071

LEFT RIGHT

RIGHT DATA VALUESUser20

User19

User18

User17

8 4 2 1

User ClosingTelco 3

LEFT DATA VALUESUser48

User47

User46

User45

8 4 2 1

ADDRESS 1074

LEFT RIGHT

RIGHT DATA VALUESUser44

User43

User42

User41

8 4 2 1

LEFT DATA VALUESUser40

User39

User38

User37

8 4 2 1

ADDRESS 1073

LEFT RIGHT

RIGHT DATA VALUESUser36

User35

User34

User33

8 4 2 1

CS

Use

r Rep

ortin

g C

odes

Page 45: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 45G

lobal System Trouble R

eporting Options

GLOBAL SYSTEM TROUBLE REPORTING OPTIONS (ADDRESS 1082-1116)

[Default = blank (�) blank (�) from address 1082-1092]

SYSTEM RESPONSEACTIVATED BY GLOBAL

EVENT/TROUBLE

Burglary Alarm Output

Pulsed Burg. Output

Fire Output

Reset Relay

Auxiliary Relay

Report Event Telco 1

Report Restore Telco 1

Report Event Telco 3

Report Restore Telco 3

GLOBAL SYSTEM EVENT/TROUBLE

LEFT DATA VALUES (CIRCLE ")SENSORWATCH

EZMTAMPER

AC FAIL LOWBATTERY

8 4 2 18 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 18 4 2 1

8 4 2 18 4 2 1

ADDRESS1082-1092

LEFT ADDR RIGHT

1082

1083

1084

1085

1086

1087

1088

1091

1092

GLOBAL SYSTEM EVENT/TROUBLE

RIGHT DATA VALUES (CIRCLE ")MEMORYFAILURE

COMM.BUS 1

ALARMSUPERV.

TESTTIMER

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

See NOTE

[Default = blank (�) blank (�) from address 1094-1104]

SYSTEM RESPONSEACTIVATED BY GLOBAL

EVENT/TROUBLE

Burglary Alarm Output

Pulsed Burg. Output

Fire Output

Reset Relay

Auxiliary Relay

Report Event Telco 1

Report Restore Telco 1

Report Event Telco 3

Report Restore Telco 3

GLOBAL SYSTEM EVENT/TROUBLE

LEFT DATA VALUES (CIRCLE ")

RSRVD. RSRVD. RSRVD. RSRVD.

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

ADDRESS1094-1104

LEFT ADDR RIGHT

blank (�) 1094blank (�) 1095blank (�) 1096blank (�) 1097blank (�) 1098blank (�) 1099blank (�) 1100blank (�) 1103blank (�) 1104

GLOBAL SYSTEM EVENT/TROUBLE

RIGHT DATA VALUES (CIRCLE ")Telemetry

FailureTelemetryTrouble RSRVD. TELCO

FAIL8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 18 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

[Default = blank (�) blank (�) from address 1106-1116]

SYSTEM RESPONSEACTIVATED BY GLOBAL

EVENT/TROUBLE

Burglary Alarm Output

Pulsed Burg. Output

Fire Output

Reset Relay

Auxiliary Relay

Report Event Telco 1

Report Restore Telco 1

Report Event Telco 3

Report Restore Telco 3

GLOBAL SYSTEM EVENT/TROUBLE

LEFT DATA VALUES (CIRCLE ")RF

TROUBLERF

TAMPERRF RCVR.TROUBLE

PROGRAMCHANGE

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 18 4 2 1

ADDRESS1106-1116

LEFT ADDR RIGHT

1106 blank (�)

1107 blank (�)

1108 blank (�)

1109 blank (�)

1110 blank (�)

1111blank (�) 1112 blank (�)

1115blank (�) 1116 blank (�)

GLOBAL SYSTEM EVENT/TROUBLE

RIGHT DATA VALUES (CIRCLE ")SERVICE

MESSAGERSRVD. RSRVD. Digital

Dialer Test8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

See NOTE

! 1. Select the desired option by circling " the data values for each digit (left and right).

! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in address location (left and right digits).NOTE: Dark shaded data value box shows option not available.

Page 46: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 46A

rea

Syst

em T

roub

le R

epor

ting

Opt

ions

AREA SYSTEM TROUBLE REPORTING OPTIONS (ADDRESS 1120-1157)

! 1. Select the desired option by circling " the data values foreach digit (left and right).

! 2. Add the data values (ex: 15=1+2+4+8) from the selectedoptions.

AR

EA 2

[Default = blank (�) blank (�) from address 1130-1137]

SYSTEM RESPONSEACTIVATED BY AREA 2

EVENT/TROUBLE

Pulsed Burg. Output

Burglary Output

Fire Output

Reset Relay

Auxiliary Relay

Report Alarm Telco 1

Report Alarm Telco 3

AREA 2 SYSTEM EVENT/TROUBLE

LEFT DATA VALUES (CIRCLE ")

RSRVD. FAIL TOCLOSE

FAIL TOOPEN

KEYPADTAMPER

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

ADDRESS1130-1137

LEFT ADDR RIGHT

1130

1131

1132

1133

1134

1135

1137

AREA 2 SYSTEM EVENT/TROUBLE

RIGHT DATA VALUES (CIRCLE ")KEYPAD

AUX.KEYPAD

FIREKEYPADPANIC AMBUSH

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

[Defaults as circled from address 1120-1127]

SYSTEM RESPONSEACTIVATED BY AREA 1

EVENT/TROUBLE

Pulsed Burg. Output

Burglary Output

Fire Output

Reset Relay

Auxiliary Relay

Report Alarm Telco 1

Report Alarm Telco 3

AREA 1 SYSTEM EVENT/TROUBLE

LEFT DATA VALUES (CIRCLE ")

RSRVD. FAIL TOCLOSE

FAIL TOOPEN

KEYPADTAMPER

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

ADDRESS1120-1127

LEFT ADDR RIGHT

1120

1121

1122

1123

1124

1125

1127

AREA 1 SYSTEM EVENT/TROUBLE

RIGHT DATA VALUES (CIRCLE ")KEYPAD

AUX.KEYPAD

FIREKEYPADPANIC AMBUSH

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 18 4 2 1

8 4 2 1

AR

EA 1

Page 47: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 47

ZONE OPTIONS / ZONES 1-16 (ADDRESS 1200-1386)

##

##

#

##

#

#

#

##

#

#

ZONE OPTIONS

50ms Loop Response (A)20ms Loop Response (A)PriorityPriority with BypassAuto-BypassSelective BypassKeyswitch ArmingAuto-Bypass Re-entryPre-Alarm WarningNever Arm24-Hour ZoneBurg. Alarm OutputPulsed Alarm OutputFire Output (Lug E9)Reset RelayAuxiliary RelayEntry/Exit 1Entry/Exit 2Exit/Entry FollowerAuto ResetSwinger ShutdownChimeAbort DelayPower-up DelayDay Zone OpenDay Zone ShortAlarm on Day ZoneAlarm Telco 1Alarm Restore 1Trouble Telco 1Trouble Restore 1Alarm Telco 3Alarm Restore 3Trouble Telco 3Trouble Restore 3No EOL ResistorSensor WatchTrouble on OpenTrouble on ShortTrouble on Night OpenZone Area 1Zone Area 22-Wire Smoke Detectors (B)Zone ANDing Group 1Zone ANDing Group 2Interior #1 BypassKeypad Sounder on AlarmFire (C)Fire Alarm Verification (C)Chime 2

ZONES 13-16LEFT DATA VALUES

(CIRCLE ")ZN16 ZN15 ZN14 ZN13

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS1302-1386

L ADDR R(�) (�)(�) (�)

1302130313041305130613071308130913101311131213131314131513161317131813191320132113221323132413251326132713281329133013351336133713381339134013411342134313441345

(�) (�)1354135513621364137513761386

ZONES 9-12RIGHT DATA VALUES

(CIRCLE ")ZN12 ZN11 ZN10 ZN9

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ZONES 5-8LEFT DATA VALUES

(CIRCLE ")ZN8 ZN7 ZN6 ZN5

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ZONES 1-4RIGHT DATA VALUES

(CIRCLE ")ZN4 ZN3 ZN2 ZN1

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS1200-1286

L ADDR R1200120112021203120412051206120712081209121012111212121312141215121612171218121912201221122212231224122512261227122812291230123512361237123812391240124112421243124412451252 (�)1254125512621264127512761286

#

#

! 1 ! 4 ! 4 ! 4 ! 4! 2 ! 2 ! 2 ! 2

See Zone Options on Page 50.

Zone Options / Zones 1-16

Page 48: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 48

! 1 ! 4 ! 4 ! 4 ! 4! 2 ! 2 ! 2 ! 2

ZONE OPTIONS / ZONES 17-32 (ADDRESS 1402-1586)

##

##

#

####

#

##

#

#

ZONE OPTIONS

PriorityPriority with BypassAuto-BypassSelective BypassKeyswitch ArmingAuto-Bypass Re-entryPre-Alarm WarningNever Arm24-Hour ZoneBurg. Alarm OutputPulsed Alarm OutputFire Output (Lug E9)Reset RelayAuxiliary RelayEntry/Exit 1Entry/Exit 2Exit/Entry FollowerAuto ResetSwinger ShutdownChimeAbort DelayPower-up DelayDay Zone OpenDay Zone ShortAlarm on Day ZoneAlarm Telco 1Alarm Restore 1Trouble Telco 1Trouble Restore 1Alarm Telco 3Alarm Restore 3Trouble Telco 3Trouble Restore 3No EOL ResistorSensor WatchTrouble on OpenTrouble on ShortTrouble on Night OpenZone Area 1Zone Area 2Zone ANDing Group 1Zone ANDing Group 2Interior #1 BypassKeypad Sounder on AlarmFire (C)Fire Alarm Verification (C)Chime 2

ZONES 29-32LEFT DATA VALUES

(CIRCLE ")ZN32 ZN31 ZN30 ZN29

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS1502-1586

L ADDR R15021503150415051506150715081509151015111512151515141515151615171518151915201521152215231524152515261527152815291530153515361537153815391540154115421543154415451554155515621564157515761586

ZONES 25-28RIGHT DATA VALUES

(CIRCLE ")ZN28 ZN27 ZN26 ZN25

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ZONES 21-24LEFT DATA VALUES

(CIRCLE ")ZN24 ZN23 ZN22 ZN21

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ZONES 17-20RIGHT DATA VALUES

(CIRCLE ")ZN20 ZN19 ZN18 ZN17

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS1402-1486

L ADDR R14021403140414051406140714081409141014111414141314141415141614171418141914201421142214231424142514261427142814291430143514361437143814391440144114421443144414451454145514621464147514761486

Zone

Opt

ions

/ Zo

nes

17-3

2

See Zone Options on Page 50.

#

Page 49: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 49

! 1 ! 4 ! 4 ! 4 ! 4! 2 ! 2 ! 2 ! 2

ZONE OPTIONS / ZONES 33-48 (ADDRESS 1602-1786)

#

##

#

#

####

#

##

#

#

ZONE OPTIONS

PriorityPriority with BypassAuto-BypassSelective BypassKeyswitch ArmingAuto-Bypass Re-entryPre-Alarm WarningNever Arm24-Hour ZoneBurg. Alarm OutputPulsed Alarm OutputFire Output (Lug E9)Reset RelayAuxiliary RelayEntry/Exit 1Entry/Exit 2Exit/Entry FollowerAuto ResetSwinger ShutdownChimeAbort DelayPower-up DelayDay Zone OpenDay Zone ShortAlarm on Day ZoneAlarm Telco 1Alarm Restore 1Trouble Telco 1Trouble Restore 1Alarm Telco 3Alarm Restore 3Trouble Telco 3Trouble Restore 3No EOL ResistorSensor WatchTrouble on OpenTrouble on ShortTrouble on Night OpenZone Area 1Zone Area 2Zone ANDing Group 1Zone ANDing Group 2Interior #1 BypassKeypad Sounder on AlarmFire (C)Fire Alarm Verification (C)Chime 2

ZONES 45-48LEFT DATA VALUES

(CIRCLE ")ZN48 ZN47 ZN46 ZN45

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS1702-1786

L ADDR R17021703170417051706170717081709171017111712171717141717171617171718171917201721172217231724172517261727172817291730173517361737173817391740174117421743174417451754175517621764177517761786

ZONES 41-44RIGHT DATA VALUES

(CIRCLE ")ZN44 ZN43 ZN42 ZN41

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ZONES 37-40LEFT DATA VALUES

(CIRCLE ")ZN40 ZN39 ZN38 ZN37

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ZONES 33-36RIGHT DATA VALUES

(CIRCLE ")ZN36 ZN35 ZN34 ZN33

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS1602-1686

L ADDR R16021603160416051606160716081609161016111616161316161615161616171618161916201621162216231624162516261627162816291630163516361637163816391640164116421643164416451654165516621664167516761686

Zone Options / Zones 33-48

See Zone Options on Page 50.

#

Page 50: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 50

! 1. Select the desired zone option.

ZONE OPTIONS50ms Loop Response10ms Loop ResponsePriorityPriority with BypassAuto-Bypass

! 2. Enable desired options for each zone by drawing a circle " around its corresponding binary data value.

NOTE: No circle = feature disabled.

48 2 1 Draw Circle

ZN04 ZN03 ZN02 ZN01

! 3. Search table below for data entry.

! 4. Enter data in address locations (left and right digits).

NOTE: Dark shaded data value boxshows option not available.

ADDRESS LOCATIONL ADDR R

blank (�) 1200 1

NOTE: See Direct AddressProgramming Example onpage 19.

48 2 1DIGIT VALUE DATA ENTRY

Blank (.)48 2 1 148 2 1 2

8 124 348 2 1 4

548 2 148 2 1 648 2 1 7

4 2 1DIGIT VALUE DATA ENTRY

84 2 1 94 2 1 0

124 B4 2 1 C

D4 2 14 2 1 E4 2 1 F

88888888

NOTES: (A) 50ms & 20 ms Loop Response only available for zones 1-8.(B) 2-wire Smoke Detectors only available for zones 7 and 8.(C) If Fire Alarm Verification is selected, then Fire must also be selected.

DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.! Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown , Zone Area 1 and Zone Area 2 are enabled for the total numberof zones entered in �AREA 1 # ZONES = 08� and �AREA 2 # ZONES = 00�.! Alarm Telco 1 is enabled for all zones if [YES] is entered for �REPORT ALL ZONES TO CENTRAL ZONES? Y/N�.! Entry/Exit 1 and Chime are enabled for zone numbers entered in �EXIT / ENTRY ZONES �.! Exit/Entry Follower and Interior Bypass are enabled for zone numbers entered in �INTERIOR ZONES�.

! Fire, Pulse Alarm Output and Fire Verification is enabled for the zone numbers entered in �FIRE ZONES�.

! 2-Wire Smoke Detector is enabled for zone numbers entered in �2 WIRE FIRE ZONES�.

Note: See �Number of Zones &Keypads per Area� in EasyMenu Driven program Mode.

ZONE OPTIONS / ZONES 1-48 (ADDRESS 1200-1786)Zo

ne O

ptio

ns /

Zone

s 1-

48

Page 51: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 51

[Default = blank (�) blank (�)]

[Default = blank (�) blank (�)]

[Default = blank (�) blank (�)]

SYSTEM OPTIONS (ADDRESS 2415-2419)

ADDRESS 2415

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

blank (�)

SYSTEM OPTIONS

Disable Fire Reset(Area 1)

Disable Fire Reset(Area 2)

RESERVED

RESERVED

ADDRESS 2417

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

RESERVED

Answering Machine P/UW/O Line Seizure

Disable Auto-Unbypasson Disarming

BypassFaulted Zones

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Opening Report onlyafter Alarm Report

Closing Report only onCond. Closing (Auto-Byp.)Include Sel./Grp. Bypassin Cond. Closing Status

Status Report(Auto-Byp. Zones on Clos.)

ADDRESS 2418

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Access Control (Panel)on Aux. Output

Enable Burg. OutputWarning on Entry

EnableManager�s ModeStart Exit Delayafter Ringback

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Auto Bell Teston Arming

Auto Reset afterBurg. Output TimeoutSuppress �Bypass�

Reminder when ArmedRESERVED

[Default = blank (�) blank (�)]

ADDRESS 2416

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

blank (�)

System O

ptions

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Enable Day Zone Watch(Area 1)

Enable Day Zone Watch(Area 2)

RESERVED

RESERVED

SYSTEM OPTIONS

RESERVED

RESERVED

RESERVED

RESERVED

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

RESERVED

RESERVED

RESERVED

RESERVED

LEFT DATAVALUES

(CIRCLE ")

1

2

4

8

[Default = blank (�) blank (�)]

! 1. Select the desired option by circling "the data values for each digit (left and right).

! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in address location (left and right digits).NOTE: Dark shaded data value box shows option not available.

ADDRESS 2419

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

DisableFunction-Mode Download

DisableCallback DownloadDisable Answering-Machine DownloadDisable Auto-Reset

on Day Zone

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Interior 1Normally Bypassed

EnableExit-Delay Restart

Reset Day Zone withArm/Disarm Only

Enable Local Alarm onFirst Zone �AND� Trip

Page 52: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 52

SYSTEM OPTIONS (ADDRESS 2420-2422, 3874 & 3879-3881)

[Default = blank (�) blank (�)]

ADDRESS 2420

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

SYSTEM OPTIONS

Disable KeypadInstant Button

EnableLine-Fault Test

Disable AC Fail Detection

Telco Failonly when Armed

[Default = blank (�) blank (�)]

ADDRESS 2421

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

AutomaticInterior Bypass *

Veri-phone Zones tripAux. Relay

Veri-phone Zones Priorityover Alarms

Aux. Output Chirp onKeyfob Arming

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Don�t Clear Aux. Relaywith Arm/DisarmTelco AnsweringService Overide

Disable Auto Status

Veri-phone Zonestrip Fire Output

* Note: If �Automatic Interior Bypass� inAddress 2421 is selected, then �Interior 1Normally Bypassed� in Address 2419 mustalso be selected.

! 1. Select the desired option by circling "the data values for each digit (left and right).

! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in address location (left and right digits).NOTE: Dark shaded data value box shows option not available.

Syst

em O

ptio

ns

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

RIGHT DATAVALUES

(CIRCLE ")

1

2

4

8

SYSTEM OPTIONS

Disable System TroubleAudible at Keypad

Chime onE4 Lug

Disable Code requiredfor Func. Mode Lvl. 1

Disable Code requiredfor Easy Bypass

[Default = blank (�) blank (�)]

ADDRESS 2422

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

RIGHT DATAVALUES

(CIRCLE ")

1

2

4

8

SYSTEM OPTIONS

Fire Output Cadence

Wireless SmokeLow Battery Resound

SupervisedAlarm Output

Enable Smoke DetectorDirty Trouble

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Disable Area Entry Relays

Disable Exit/Entry UrgencyTone at Keypad

Enable Burg. Output forKeyfob Chirp

Enable Burg. Output on TelcoFail only when Armed

[Default = blank (�) blank (�)]

ADDRESS 3874

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Enable GEM-PRINT

Cancel Reportto Telco 3

Report Wireless Troubleto Telco 1

Report Wireless Troubleto Telco 3

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Enable Set Time/Date

RESERVED

EnableTime/Date Display

RESERVED

[Default = blank (�) blank (�) from address 3879-3881]

ADDRESS3879-3881

LEFT ADDR RIGHTblank (�) 3879blank (�) 3880blank (�) 3881

ALARM/TROUBLEREPORTING CODES

Wireless Low BatteryWireless Supervisory

Wireless Tamper

Page 53: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 53

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Disable System TroubleAudible Timeout

RESERVED

RESERVED

RESERVED

[Default = blank (�) blank (�)]

ADDRESS 4084

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

blank (�)

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

RESERVED

RESERVED

RESERVED

Disable AutoDial Tone Detection

Note: Right digit is RESERVED(not used). Enter data in left digitonly.

SYSTEM OPTIONS (ADDRESS 3882-3901, 3903-3905 & 4084)

Telephone NumberDialing Prefix(Digits 1-20)

ADDRESS 3882-3901 (RIGHT DIGITS 1-20)3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901

R R R R R R R R R R R R R R R R R R R R

[Default = blank (�) blank (�)]

ADDRESS 3903LEFT RIGHTPager Format:

Re-sends ofFirst Report

[Default = blank (�) blank (�)]

ADDRESS 3904LEFT RIGHTPager Format:

Maximum Pagesper Session

[Default = blank (�) blank (�)]

ADDRESS 3905

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

blank (�) blank (�)Note: Left digit is RESERVED(not used). Enter data in rightdigit only.

System O

ptions

Page 54: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 54

RIGHTblank (�)

12

OPTIONNot Used

Area 1Area 2

KEYPAD AREAASSIGNMENT

KEYPAD OPTIONS: Select options for any of the 7 keypads.* Note: For Remote Access Control only (no Arm/Disarm capability).! 1. Select the desired option by circling " the data values for each digit (left and right).

! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in address location (left and right digits). NOTE: Dark shaded data value box shows option not available.

[Default = blank (�) and (7) for address 2440]

KEYPADNO.

1

2

3

4

5

6

7

KEYPAD OPTIONS

LEFT DATA VALUES (CIRCLE ")TOUR

STATIONPANEL

ACCESSEASY

ARMING AMBUSH

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS2440-2446

LEFT ADDR RIGHT

2440

2441

2442

2443

2444

2445

2446

KEYPAD OPTIONS

RIGHT DATA VALUES (CIRCLE ")Rem. Acc.

Only *KEYPADPANIC

KEYPADAUXILIARY

KEYPADFIRE

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

8 4 2 1

KEYPAD OPTIONS (ADDRESS 2425-2446)K

eypa

d O

ptio

ns

[Default = blank (�) blank (�)]

ADDRESS 2428LEFT RIGHT

blank (�)

Keypad 4 Type& Area

Assignment

[Default = blank (�) 1]

ADDRESS 2425LEFT RIGHTKeypad 1 Type

& AreaAssignment

[Default = blank (�) blank (�)]

ADDRESS 2426LEFT RIGHT

blank (�)

Keypad 2 Type& Area

Assignment

[Default = blank (�) blank (�)]

ADDRESS 2427LEFT RIGHT

blank (�)

Keypad 3 Type& Area

Assignment

[Default = blank (�) blank (�)]

ADDRESS 2429LEFT RIGHT

blank (�)

Keypad 5 Type& Area

Assignment

[Default = blank (�) blank (�)]

ADDRESS 2430LEFT RIGHT

blank (�)

Keypad 6 Type& Area

Assignment

[Default = blank (�) blank (�)]

ADDRESS 2431LEFT RIGHT

blank (�)

Keypad 7 Type& Area

Assignment

KEYPAD TYPE & AREA ASSIGNMENT: Up to 7 keypads may be programmed, if they areconnected.NOTE: See Keypad Configuration Mode. By default from the factory, each keypad isconfigured as number 1.! 1. Select keypad type & area assignment for each keypad from the tables shown.! 2. Enter in corresponding right and left digit address locations above.

LEFT OPTIONblank

(�)Burg Keypad

2 Wizard Keypad

KEYPAD TYPE

Page 55: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 55

[Default = blank (�) blank (�) from address 2500-2547]

USER AREA OPTIONS (ADDRESS 2500-2547)

! 1. Select the desired user number.

USERNO.

12345

! 2. Enable desired areas for each user by drawing a circle " around its corresponding binary data value.

NOTE: No circle = feature disabled.

48 2 1 Draw Circle

ZN04 ZN03 ZN02 ZN01

! 3. Search table below for data entry.

! 4. Enter data in address locations (left and right digits).

ADDRESS LOCATIONL ADDR R

blank (�) 2500 148 2 1

DIGIT VALUE DATA ENTRYBlank (.)

48 2 1 148 2 1 2

8 124 348 2 1 4

548 2 148 2 1 648 2 1 7

4 2 1DIGIT VALUE DATA ENTRY

84 2 1 94 2 1 0

124 B4 2 1 C

D4 2 14 2 1 E4 2 1 F

88888888

A4 A3 A2 A1

User A

rea Options

USERNO.

123456789

101112131415161718192021222324252627282930313233343536373839404142434445464748

ADDRESS2500-2547

L ADDR R(�) 2500(�) 2501(�) 2502(�) 2503(�) 2504(�) 2505(�) 2506(�) 2507(�) 2508(�) 2509(�) 2510(�) 2511(�) 2512(�) 2513(�) 2514(�) 2515(�) 2516(�) 2517(�) 2518(�) 2519(�) 2520(�) 2521(�) 2522(�) 2523(�) 2524(�) 2525(�) 2526(�) 2527(�) 2528(�) 2529(�) 2530(�) 2531(�) 2532(�) 2533(�) 2534(�) 2535(�) 2536(�) 2537(�) 2538(�) 2539(�) 2540(�) 2541(�) 2542(�) 2543(�) 2544(�) 2545(�) 2546(�) 2547

AREAS 1-4RIGHT DATA VALUES

(CIRCLE ")A4 A3 A2 A18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

! 1 ! 4 ! 4 ! 2

Page 56: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 56

EZM GROUP OPTIONS (ADDRESS 2600-2627)

Default depends on Easy Menu Question �# OF ZNS IN AREA1� and �# OF ZNS IN AREA1�.For example, if 32 zones are used, then all 6 groups will be automatically enabled.If only 8 zones are used, then groups 1-6 will be automatically disabled.

ADDRESS 2600LEFT RIGHTblank

(�)

EZM Group 1ZONES 9-12

ADDRESS 2601LEFT RIGHTblank

(�)

EZM Group 2ZONES 13-16

ADDRESS 2602LEFT RIGHTblank

(�)

EZM Group 3ZONES 17-20

ADDRESS 2603LEFT RIGHTblank

(�)

EZM Group 4ZONES 21-24

ADDRESS 2604LEFT RIGHTblank

(�)

EZM Group 5ZONES 25-28

ADDRESS 2605LEFT RIGHTblank

(�)

EZM Group 6ZONES 29-32

NOTE: Zones 1-8 are included in the control panel and Zones 9-32 (Groups 1-6) are EZM Zones (either Wireless or Hardwired). Zones 33-48 must be wireless zones only (No EZM groups can be assigned to these zones).

DATAENTRIES

RIGHT

blank (�)

1

OPTION

Not used(No EZMpresent)

4-ZoneEZM

EZM TYPE EZM GROUP OPTIONS: Up to 6 Groups of 4 Zones each may be programmed depending on the number ofzones used and which EZM modules are connected. Each group represents 4 zones.! 1. Select EZM type from the table shown.! 2. Enter in corresponding address locations above (right digit only).NOTE: Dark shaded data value box shows option not available.

EZM PGM ARMED TERMINAL CONTROL: For each zone group select the area(s) which, when armed, will activate the PGM Lug onthe corresponding EZM modules. Each zone group corresponds to 4 zones. If 8-Zone EZMs are used each one is treated as TWO zonegroups. NOTE: Lug goes ACTIVE (low) when ANY selected area is armed. When activated, the PGM Lug goes negative (to Ground).! 1. Select the desired group number.! 2. Enable desired options for each area by drawing a circle " around its corresponding binary data value.

NOTE: No circle = feature disabled.! 3. Enter data in corresponding left and right digit address locations above.

[Default = blank (�) blank (�) from address 2622-2627]

GROUPNO.

123456

LEFT DATA VALUES(CIRCLE ")

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS2622-2632

L ADDR R(�) 2622(�) 2623(�) 2624(�) 2625(�) 2626(�) 2627

AREAS 1-2RIGHT DATA VALUES

(CIRCLE ")A2 A1

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

EZM PGM TERMINAL CONTROL

EZM

Gro

up O

ptio

ns

Page 57: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 57

AREA ARMING OPTIONS (ADDRESS 2650-2651)

PRIORITY AREA ARMING:! 1. Select the desired arming area.! 2. Enable desired options for each priority area by drawing a circle " around its corresponding binary data value.

NOTE: No circle = feature disabled.! 3. Enter data in corresponding left and right digit address locations above.NOTE: Dark shaded data value box shows option not available.

[Default = blank (�) blank (�) from address 2650-2657]

ARMINGAREA

AREA 1AREA 2

ADDRESS2650-2651

L ADDR R(�) 2650(�) 2651

AREAS 1-2RIGHT DATA VALUES

(CIRCLE ")A2 A1

8 4 2 18 4 2 1

PRIORITY AREA ARMING

REMOTE ACCESS LOGGING (ADDRESS 3184)

[Default = blank (�) blank (�)]

ADDRESS 3184

LEFT DIGIT (SUMOF DATA VALUES)

RIGHT DIGIT (SUMOF DATA VALUES)

LEFT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Enable Keypad 5

Enable Keypad 6

Enable Keypad 7

RESERVED

RIGHT DATAVALUES

(CIRCLE ")1

2

4

8

SYSTEM OPTIONS

Enable Keypad 1

Enable Keypad 2

Enable Keypad 3

Enable Keypad 4

REMOTE ACCESS LOGGING: Enable logging of every keypad access event.! 1. Select the desired option by circling "the data values for each digit (left and right).

! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in address location (left and right digits).NOTE: Dark shaded data value box shows option not available.

Area A

rming O

ptions & R

emote A

ccess Logging

Page 58: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 58

AREA OUTPUT CONTROL OPTIONS (ADDRESS 2700-2733)

AREA OUTPUT TURNS OFF UPON DISARM: Select options for any of the 5 Outputs per area when disarming a particular area.! 1. Select the desired option by circling " the data values for left and right digits.

! 2. Add the data values (ex: 15=1+2+4+8) from the selected options.! 3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available.

Are

a O

utpu

t Con

trol

[Default = 2700 (�1) 2708 (�1) ]

OUTPUT SILENCED(TURNED OFF)

Burglary OutputPulsed Burg. Output

Fire OutputReset Relay

Auxiliary Relay

LEFT DATA VALUES(CIRCLE ")

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS2700-2732

L ADDR R(�) 2700(�) 2708(�) 2716(�) 2724(�) 2732

AREAS 1-2RIGHT DATA VALUES

(CIRCLE ")A2 A1

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

DISARMING AREA 1 TURNS OFF AREA OUTPUT

LEFT DATA VALUES(CIRCLE ")

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

ADDRESS2701-2733

L ADDR R(�) 2701(�) 2709(�) 2717(�) 2725(�) 2733

AREAS 1-2RIGHT DATA VALUES

(CIRCLE ")A2 A1

8 4 2 18 4 2 18 4 2 18 4 2 18 4 2 1

DISARMING AREA 2 TURNS OFF AREA OUTPUT

Page 59: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 59

RF RECEIVERS & SUPERVISORY TIMER OPTIONS (ADDRESS 3776 & 3760-3775)

Default for Number of Receiversdepends on Easy Menu Question forRF Transmitters.

ADDRESS 3776LEFT RIGHT

blank (�)

Number of RFReceivers

DATAENTRIES

RIGHTblank (�)

12

RF Receiver(s)

None12

RF RECEIVERS: Up to 2 RF Receivers may be programmed.NOTE: This adds wireless capability to the system, increasingup to 48 the number of zones.! 1. Select the number of receivers from the table shown.! 2. Enter in corresponding right digit address location shown

(left digit is not used).

[Default = blank (�) blank (�) from address 3760-3767]

ADDRESS3760-3767

LEFT ADDR RIGHT37603761376237633764376537663767

RF SUPERVISORYTIMER

RF TRANSMITTER

Type 0 Window/Door, 2 Pt.Type 1 Window/Door, 2 Pt.Type 2 Window/Door, 2 Pt.Type 3 Window/Door, 2 Pt.Type 4 Window/Door, 4 Pt.Type 5 PIRType 6 PIRType 7 Smoke Detector

[Default = blank (�) blank (�) from address 3768-3775]

ADDRESS3768-3775

LEFT ADDR RIGHT37683769377037713772377337743775

RF SUPERVISORYTIMER

RF TRANSMITTER

Type 8 Smoke DetectorType 9 KeyfobType A Dual Tech.Type B KeyfobType C Window/Door, 4 Pt.Type D PIRType E Smoke DetectorType F Napco Glass Break

DATA ENTRIESLEFT RIGHT

blank (�) blank (�)blank (�) 1blank (�) 2blank (�) 3blank (�) 4blank (�) 5blank (�) 6blank (�) 7blank (�) 8blank (�) 9blank (�) 0blank (�) Bblank (�) Cblank (�) Dblank (�) Eblank (�) F

1 blank (�)1 11 21 31 41 51 61 71 81 91 01 B1 C1 D1 E1 F2 blank (�)2 12 22 32 42 5

DELAY

0 min.30 min.60 min.90 min.120 min.150 min.180 min.210 min.240 min.270 min.300 min.330 min.360 min.390 min.420 min.450 min.480 min.510 min.540 min.570 min.600 min.630 min.660 min.690 min.720 min.750 min.780 min.810 min.840 min.870 min.900 min.930 min.960 min.990 min.

1020 min.1050 min.1080 min.1110 min.

RF SUPERVISORY TIMERSDATA ENTRIESLEFT RIGHT

2 62 72 82 92 02 B2 C2 D2 E2 F3 blank (�)3 13 23 33 43 53 63 73 83 93 03 B3 C3 D3 E3 F4 blank (�)4 14 24 34 44 54 6

F F

DELAY

1140 min.1170 min.1200 min.1230 min.1260 min.1290 min.1320 min.1350 min.1380 min.1410 min.1440 min.1470 min.1500 min.1530 min.1560 min.1590 min.1620 min.1650 min.1680 min.1710 min.1740 min.1770 min.1800 min.1830 min.1860 min.1890 min.1920 min.1950 min.1980 min.2010 min.2040 min.2070 min.2100 min.

7650 min. = 127Hr., 30 min.

RF SUPERVISORY TIMERS RF SUPERVISORY TIMERS: RF Supervisory Timers may beprogrammed for each type of transmitter used. A transmitter will send atransmission every time it is tripped, when there is NO activity, thetransmitter sends a status transmission about once an hour. If thereceiver does NOT receive ANY signal (a trip or a status) from atransmitter in the time specified for transmitter type, a system trouble �RFSUPERVISORY FAILURE� will be displayed at the keypad.! 1. Select timer delay from the table shown. Timers are programmed

in increments of 30 minutes each. Valid entries are 03-FF, 90 minutes-7650 min (127 hr,30 min).WARNING: Timers have uncertainty of +/-30 minutes. Do not use entries 0-2 (shaded areas).

! 2. Enter in corresponding address locations above (left and right digits).

! 3. For a desired timer not listed do the following:A. Choose a desired timer (intervals of 30),

ex: 3000 min. (50 Hours)

B. Divide it by 30, ex: 3000/30 = 100

C. Divide it by 16

6 Quotient Left Digit16 100 96

4 Remainder Right Digit

NOTE: These timers apply only to Supervised RF Transmitters (seeRF Transmitters in Easy Menu Driven Mode Programming).

RF R

eceivers & Supervisory Tim

er Options

Page 60: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 60

SYSTEM RESET OPTIONS (ADDRESS 4091-4093)

Clear Dealer Program (Erases Dealer Program)

This erases the dealer program. Use this feature to start acustomized default program.

Access address 4091, then press the Jbutton. Data entry is not allowed.

NOTE: Enter Easy Menu Driven Program Mode to program system again.

GEM-RP1CAe2 Keypad

4091 XX

GEM-RP2ASe2 Keypad

4091XX

Cold Start (Erases Entire Program)

This erases the entire program (codes, schedules, foreignlanguage configuration, etc), leaving the panel as it cameright out of the box.

Access address 4093, then press the Jbutton. Data entry is not allowed.

NOTE: Some features (schedules, language configuration) can only bere-programmed with the Downloading Software.

GEM-RP1CAe2 Keypad

4093 XX

GEM-RP2ASe2 Keypad

4093XX

Syst

em R

eset

Opt

ions

Page 61: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 61

USER PROGRAM MODE

PRELIMINARY INFORMATIONThe User Program Mode is covered in detail in the operating instructions for the keypad in use.! Only Keypad #1 may be used for programming, however this keypad may be located in any area.! The Program Mode cannot be accessed while the communicator is transmitting except during the first three minutes after power-

up or while any area is armed.

! After entering codes or data, press the save Jbutton. Data will not be stored into memory unless this button is pressed.

! If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound. Press the C button to silence the sounder and exit the User Program Mode.

If a GEM-RP2ASe2 is used, configure address jumpers as Keypad #1 (see the section of this manual Configuring the GEM-RP2ASe2 Keypad). Use the A button to manually scroll the display at the end of each programming line.

NOTE: For ease of programming, it is recommended that a GEM-RP1CAe2 be used as Keypad #1. (A new GEM-RP1CAe2 isautomatically configured as Keypad #1.)

ACCESSING USER PROGRAM MODE

1. Press EEEEEE A

2. Press g Until �ACTIVATE PROGRAM Y/N� (GEM-RP1CAe2) or�TURNON PROG Y/N� (GEM-RP2ASe2)appears on LCD screen.

3. Press F To Enter User Program Mode

4. Press C To Exit User Program Mode when finished

New Panel (Default User Code = 123)Existing Panel (Any Code with User Program Option Enabled)

USER CODES

Up to 48 User Codes may be programmed.NOTE: In this mode, only the code isprogrammable; the accompanying Area Optionsmust be programmed in the Dealer ProgramMode (see page 9).

! Use the A button to place the cursor over the User Number.

! Enter a User Number (01�48) using the number buttons. The cursor will then advance to the User Code and read the existing code, if any.

GEM-RP1CAe2 Keypad (Direct Entry)

ENTER USER CODEU01 123___ -_ _ -__

Programming User Codes

User Code NOT USED

To Program User Codes

1. Set Cursor Position usingthe A button.

2. Enter 2-digit User Number (01-96) directly using number buttons (0-9).

3. Enter Code (1-6 digits) directly using number buttons (0-9).

4. Press the Jbutton to save

each code.

NOTE: Press G 0 button to clear character at cursor.To continue press E or F button.

R

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

# OF ZONES IN AREA 1ENTER # ZONES X XENTER USER CODE����������������U01 123___ - _1 - __

User Program

Mode: A

ccessing Program M

ode

Page 62: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 62

ZONE DESCRIPTIONS (GEM-RP1CAE2 KEYPADS ONLY)

Enter an identifying description for eachzone. Buttons 1 and 2 set thecursor position; buttons 3 and 6scroll numbers, letters, punctuation marks,etc.! Position the cursor over the displayed

Zone Number (i.e., �01�) using buttons 1 and 2.

! Change the Zone Number using buttons 3 and 6.

! Position the cursor over the first character of the description field. Advancing the cursor between characters, program a description of up to two lines for the new zone using buttons 3 and 6.

! Press the Jbutton to save. Advance to the next zone as in Steps 1 and 2 above and repeat this procedure until all zones have

been programmed.

! Enter the new User Code using the number buttons (0-9). If an old code is displayed, program over it. To erase the digit at the cursor, press G 0 button.

! Press the Jbutton to save the code in memory.

! Repeat this procedure for each user. To proceed to Zone-Description programming, press the NEXT (E) button .

GEM-RP2ASe2 Keypad

USER01

(Direct Entry)

123___

Programming User Codes (GEM-RP2ASe2)

To Program User Codes

1. Enter 2-digit User Number (01-96) directly using number buttons (0-9).

2. Press the A button.3. Enter Code (1-6 digits)

directly using number buttons (0-9).

4. Press the Jbutton to save

each code.

NOTE: Press G 0 button to clear character at cursor.To continue press E or F button.

Programming Zone Descriptions

To Program Zone Descriptions

1. Set the Cursor Position using buttons 1 and 2.

2. Select characters for zone description using buttons 3 and 6.

4. Press the Jbutton to save

each descriptor.

NOTE: Press G 0 button to clear character at cursor.To continue press E or F button.

01-______________________________

Use

r Pro

gram

Mod

e: Z

one

Des

crip

tions

Page 63: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 63

KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2 and GEM-RP2ASe2 Keypads. If there is more than one keypad in thesystem, only Keypad No. 1 may be used for programming.

KEYPAD INSTALLATIONThree types of keypads may be used with the GEM-P9600: the GEM-RP1CAe2, GEM-RP2ASe2 and the GEM-RP3DGTL. Eachmust be assigned an address number (1�7 and each requires its own configuration procedure (see CONFIGURING THE KEYPADS,which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation.GEM-RP1CAe2 - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a PGM output. AGEM-RP1CAe2 is recommended for use as Keypad #1.GEM-RP2ASe2 - is a utility LCD keypad combining several preset LCD words with a limited message line. NOTE: Due to spaceconstraints, available messages are abbreviated and will scroll automatically.GEM-RP3DGTL -is a 2 digit LED display keypad for arming and disarming.CONFIGURING THE KEYPADSA total of up to 7 keypads may be connected to the panel. GEM-RP1CAe2 and GEM-RP2ASe2 keypads may be intermixed butrequire different configuration procedures, as described in the following paragraphs.Configuring the GEM-RP1CAe2 KeypadEach GEM-RP1CAe2 keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d) compatibilitynumber; (e) EZM address; and (f) zone response.To enter the GEM-RP1CAe2 Configuration Mode:1. Move jumper JP5 (located at the upper-right corner of the control panel board) from Pins 1-2 (top two) to Pins

2-3 (bottom two). NOTE: See Wiring Diagram on page 75.2. After about 15 seconds, the display will read �XX OUT OF SYSTEM�, where XX indicates the keypad address.3. Press 11123 A and proceed as follows. (Repeat the following procedure

for all keypads.)

Keypad Tactile BeepUpon entering the Keypad Configuration Mode, �KEYPAD BEEP ON� will be displayed,indicating that the tactile beep, which sounds when any button is pressed, is on. Toturn off the tactile beep, press the Jbutton (the Jbutton will toggle the tactile

beep on and off).Press the A button to continue or press the C button to exit.

Entry SounderTo turn off the keypad sounder during entry time, press the Jbutton (the Jbutton

will toggle the tactile beep on and off). Press the A button to continue orpress the C button to exit.

Keypad AddressIf more than one keypad is installed, each must be assigned a unique keypadaddress (that is, no two keypads may be numbered alike):

! keypads must be numbered consecutively (missing numbers are not permitted)! only Keypad No. 1 may be used for programming.To assign the keypad number, proceed as follows:

1. Enter the assigned keypad number 01�15, then press the Jbutton to save. A valid number will be acknowledged by a short

beep; an invalid number will be rejected by a long beep.

2. Press the A button to continue or press the C button to exit.

KEYPAD BEEP ON

ENTRY SOUNDER ON

KEYPAD ADDRESS 01

NORMALKEYPADCONFIGURE

R

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARMED STATUS

SYSTEM ARMED01/01/97 12:00AM

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

# OF ZONES IN AREA 1ENTER # ZONES X XKEYPAD BEEP ON

Keypad C

onfiguration Mode: C

onfiguring the Keypads

Page 64: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 64

Compatibility NumberThe compatibility number is a 4-digit security code that, if programmed intoboth the control panel and each GEM-RP1CAe2 keypad, dedicates thekeypad to only that panel. That is, (a) similar keypads not having thecorrect compatibility number will not operate in the system and (b) a

keypad may not be removed for use on a system with a different compatibility number. Press the A button tocontinue or press the C button to exit.

EZM AddressThe keypad's internal EZM (Expansion Zone Module) may be utilized toprovide four additional wired zones. Whether used alone or in conjunctionwith optional GEM-EZM series modules or other keypad EZMs, it must beassigned a unique address (or Group number, see Keypad ProgrammingWorkbook) similar to its keypad address. If no other EZMs are to be used,

designate the keypad as Group �01� at the �EZM ADDRESS 00� display. In multiple-EZM systems, enter an assignedgroup number �01� through �06�. (Each EZM must have a unique assigned group number, starting with �01� andproceeding consecutively.) Press the Jbutton. Press the A button to continue or press the C button to exit.

Zone ResponseThe normal loop response of each keypad expansion zone is 750mS,however the response time of any zone can be reduced to 50mS asfollows.

1. Of the following, circle the number(s) in parentheses associated with the zone(s) to be changed:Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)2. Add up the circled numbers.3. At the keypad, enter the sum as a two-digit number �01� through �15� on the display, then press the Jbutton.Example. Change Zones 2, 3 and 4 to 50mS response.1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).2. Add up the circled numbers: 2 + 4 + 8 = 14.3. Enter �14� at the keypad, then press the Jbutton.Press the A button to continue or press the C button to exit the Keypad Configuration Mode (display will read�01 OUT OF SYSTEM�). Then replace Jumper JP5 across Pins 1�2 (top two).

NEW COMPAT# 0000

EZM ADDRESS 01

ZONE RESPONSE 00

Key

pad

Con

figur

atio

n M

ode:

Con

figur

ing

the

Key

pads

Page 65: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 65

NAPCO Security Systems, Inc.333 Bayview Avenue, Amityville, New York 11701

For Sales and Repairs, call toll free: (800) 645-9445For direct line to Technical Service, call toll free: (800) 645-9440

Internet: http://www.napcosecurity.com

Keypad C

onfiguration Mode: C

onfiguring the Keypads

Configuring the GEM-RP2ASe2 and GEM-RP3DGTL KeypadUp to 7 GEM-RP2ASe2 and/or GEM-RP3DGTL keypads may be connected to the panel (Keypads 1�7). Each mustbe configured for a keypad address. In addition, the keypad may be configured to disable (a) touchpad backlight; (b)LCD backlight; and (c) entry sounder. Keypads are configured by the proper selection of jumpers. Refer to the labelon the circuit board insulation paper for jumper locations and a summary of settings.

KEYPAD ADDRESSIf more than one keypad is installed:! Each must be assigned a unique address (that is, no two keypads maybe numbered alike).! Keypads must be addressed consecutively (that is, missing numbers arenot permitted).! Only Keypad No. 1 may be used for programming. (However, for ease ofprogramming, it is recommended that a GEM-RP1CAe2 be selected asKeypad #1.)Assign the keypad address number by selecting Jumpers J1�3 inaccordance with the table at left.*Note: (1) Keypads are factory supplied with no jumpers installedand as such are automatically configured as Keypad No. 1. (2) Onlyone keypad in the system may be configured as Keypad No. 1,otherwise none will function.

TOUCHPAD BACK LIGHTCut Jumper A to disable touch pad backlighting to conserve 11mA standby current.

LCD BACKLIGHTCut Jumper B to disable LCD backlighting.

DISABLE SOUNDERCut Jumper C to disable the sounder. (Do not disable in UL applications.)

KEYPADNUMBER

1

2

3

4

5

6

7

1 2 3

OFF orON*

OFF OFF

OFF ON OFF

ON ON OFF

OFF OFF OFF

ON OFF ON

OFF ON ON

ON ON ON

KEYPAD NUMBER

PARK

STORE SPAREJUMPER AT THIS

POSITION

Page 66: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 66

KEYPAD PROGRAMMING MODESNote:

! 1. Functions that are not active, not programmed and/or not applicable to user�s authority level will besuppressed and will not display.! 2. Due to space constraints, GEM-RP2ASe2 messages are abbreviated (D).! 3. Many functions will not be displayed (such as: �DISPLAY ZN FAULTS�). It will require a faulted zone to display.

124

356

7890

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

Scroll Down

Scroll Up

Exit

Yes

NoPress Abutton

FUNCTION LEVEL (A)

DISPLAY ZN FAULTS 1

DISPLAY ZN BYPASSED 1

DISPLAY ZN DIRECTORY 1

ACTIVE BELL TEST 1

DISPLAY PHONE #�S 1

DISPLAY SYS TRBL 1

DISPLAY FIRE ALARM 1

DISPLAY FIRE TRBL 1

DISPLAY OP/CL 3

ACTIVATE OVERVIEW 3 (B)

ACTIVATE CHIME 1

ACTIVATE WATCH 2

RESET SYSTEM TRBL 3

RESET SENSOR MSG 3

START EXIT TIME 1

FAULT FIND (C)

ACTIVATE LOCATE (C)

EZM ZONE FIND (C)

FUNCTION LEVEL (A)

ACTIVATE DIALER TEST 3

DISPLAY ALARM LOG (D) 3

DISPLAY TOTAL LOG (D) 3

DISPLAY FIRE LOG (D) 3

DISPLAY OP/CL LOG (D) 3

DISPLAY SYSTEM LOG (D) 3

TO ARM IN 1-4HRS 2

DISPLAY AUTO ARM SCHD 3

ACTIVATE PROGRAM 3 (B)

ACTIVATE DOWNLOAD 3

DISPLAY RF XMITTER STAT 3

RELAY CONTROL 1

FUNCTION MODE

(A) Minimum level required to access function(B) Level 3 code with appropriate option(C) Requires dealer code(D) Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads(E) Initial Configuration only; suppressed thereafter

Key

pad

Prog

ram

min

g M

odes

: Fun

ctio

n M

ode

Page 67: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 67

Keypad Commands

124

356

7890

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

Scroll Down

Scroll Up

Exit

Yes

NoEnter Dealer Code

FUNCTION LEVEL (A)

DISPLAY ZN FAULTS 1

DISPLAY ZN BYPASSED 1

DISPLAY ZN DIRECTORY 1

ACTIVE BELL TEST 1

DISPLAY PHONE #�S 1

DISPLAY SYS TRBL 1

DISPLAY FIRE ALARM 1

DISPLAY FIRE TRBL 1

DISPLAY OP/CL 3

ACTIVATE OVERVIEW 3 (B)

ACTIVATE CHIME 1

ACTIVATE WATCH 2

RESET SYSTEM TRBL 3

RESET SENSOR MSG 3

START EXIT TIME 1

FAULT FIND (C)

ACTIVATE LOCATE (C)

EZM ZONE FIND (C)

FUNCTION LEVEL (A)

ACTIVATE DIALER TEST 3

DISPLAY ALARM LOG (D) 3

DISPLAY TOTAL LOG (D) 3

DISPLAY FIRE LOG (D) 3

DISPLAY OP/CL LOG (D) 3

DISPLAY SYSTEM LOG (D) 3

TO ARM IN 1-4HRS 2

DISPLAY AUTO ARM SCHD 3

ACTIVATE PROGRAM 3 (c)

ACTIVATE DOWNLOAD 3

DISPLAY RF XMITTER STAT 3

RELAY CONTROL 1

DEALER MODE

Press Abutton

EASY MENU PROGRAMMODE

(A) Minimum level required to access function(B) Level 3 code with appropriate option(C) Requires dealer code(D) Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads(E) Initial Configuration only; suppressed thereafter

Keypad Program

ming M

odes: Dealer M

ode

Page 68: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 68

Keypad Commands1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

Set Cursor

Exit

Yes/Scroll Down

No/Scroll Down

ExecuteFUNCTION

AREA 1 # OF ZONES (E)

AREA 2 # OF ZONES (E)

FIRE ZONE NUMBERS (E)

2 WIRE FIRE ZONE NUMBERS (E)

REPORT ALL ZONES TO CENTRAL? Y/N (E)

EXIT/ENTRY ZONE NUMBERS (E)

INTERIOR ZONE NUMBERS (E)

AREA 1 # OF KEYPADS

AREA 2 # OF KEYPADS

CENTRAL PHONE NO.

ACCOUNT # (_ _ _ _)

RCVR FORMAT

ENTER USER CODE

ENTER ZONE DESCRIPTIONS

RF XMITTER ID CODE # + POINTS

KEY FOB ID CODE # + OPTIONS

ENTER DATE (MM/DD/YY)

ENTER TIME (HH:MMA/P)

ENTER DEALER CODE

EASY MENU MODE

(A) Minimum level required to access function(B) Level 3 code with appropriate option(C) Requires dealer code(D) Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads(E) Initial Configuration only; suppressed thereafter

Press Cbutton

(at any time)

DIRECT ADDRESSPROGRAM MODE

Key

pad

Prog

ram

min

g M

odes

: Eas

y M

enu

Mod

e

Page 69: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 69

Keypad Commands

1 24

35 6

7 8 9 0

ABC

D EFG

NEXT/YES

PRIOR/NO

AREA

Scroll Down/Set Cursor

Scroll Up

Exit

Yes

No

Execute

Enter User Code

FUNCTION LEVEL (A)

DISPLAY ZN FAULTS 1

DISPLAY ZN BYPASSED 1

DISPLAY ZN DIRECTORY 1

ACTIVE BELL TEST 1

DISPLAY PHONE #�S 1

DISPLAY SYS TRBL 1

DISPLAY FIRE ALARM 1

DISPLAY FIRE TRBL 1

DISPLAY OP/CL 3

ACTIVATE OVERVIEW 3 (B)

ACTIVATE CHIME 1

ACTIVATE WATCH 2

RESET SYSTEM TRBL 3

RESET SENSOR MSG 3

START EXIT TIME 1

FAULT FIND (C)

ACTIVATE LOCATE (C)

EZM ZONE FIND (C)

FUNCTION LEVEL (A)

ACTIVATE DIALER TEST 3

DISPLAY ALARM LOG (D) 3

DISPLAY TOTAL LOG (D) 3

DISPLAY FIRE LOG (D) 3

DISPLAY OP/CL LOG (D) 3

DISPLAY SYSTEM LOG (D) 3

TO ARM IN 1-4HRS 2

DISPLAY AUTO ARM SCHD 3

ACTIVATE PROGRAM 3 (B)

ACTIVATE DOWNLOAD 3

DISPLAY RF XMITTER STAT 3

RELAY CONTROL 1

USER MODE

Press Abutton

USER CODES

(A) Minimum level required to access function(B) Level 3 code with appropriate option(C) Requires dealer code(D) Not available in GEM-RP2ASe2 / GEM-RP3DGTL keypads(E) Initial Configuration only; suppressed thereafter

ZONE DESCRIPTIONS

(01-96)

Press Cbutton

(at any time)

Keypad Program

ming M

odes: User M

ode

DATE AND TIME

Page 70: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 70

KEYPAD CONFIGURATION MODE

GEM-RP1CAe2KEYPADS

Press Abutton

Enter Factory Code:11123

Configure:• Keypad Beep ON/OFF• Entry Sounder• Keypad Address 01• New Compat# 000 **• EZM Address 00• Zone Response 00• Program Control Message# 1

Press Cbutton

(�01 OUT OF SYSTEM�)

Return Jumper JP5 * from Pins 2-3 to Pins 1-2(�SYSTEM READY�)

Move Jumper JP5 * from Pins 1-2 to Pins 2-3(Wait about 15 seconds: �OUT OF SYSTEM�)

Configure:• Keypad Address (Jumpers J1-J3)• Touchpad Backlight (Jumper A)• LCD Backlight (Jumper B)• Entry Sounder (Jumper C)

GEM-RP2ASe2KEYPADS

* JP5 is located at the top-right corner of the circuit board.** If a Compatibility Number other than �0000� is programmed, �OLD COMPAT# XXXX� is displayed.

Key

pad

Prog

ram

min

g M

odes

: Key

pad

Con

figur

atio

n M

ode

GEM-RP3DGTLKEYPADS

Configure:• Keypad Address (Jumpers J1-J3)• Touchpad Backlight (Jumper A)• Entry Sounder (Jumper C)• Enable Tamper LED (Jumper E)

Page 71: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 71

PROGRAMMING OPTIONS INDEXPROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER

10ms Loop Response Direct Address 1201 47 - 491400hz Handshake/Kissoff Direct Address 0526,0551 & 0576 452300hz Handshake/Kissoff Direct Address 0526,0551 & 0576 4524-Hour Zone (Zone Option) Direct Address 1210, 1310, 1410 & 1510 47 - 492-Wire Smoke Detectors (Zone Option) Direct Address 1252 473/1 With Extended Restores Direct Address 0526,0551 & 0576 4550ms Loop Response Direct Address 1200 47 - 49Abort Delay per zone Direct Address 1222, 1322, 1422 & 1522 47 - 49Abort Delay Timeout Direct Address 2406 35AC Fail Report Delay Direct Address 2408 35Access Control (Panel) On Aux. Output Direct Address 2418 51Alarm On Day Zone Direct Address 1226, 1326 1426 & 1526 47 - 49Alarm Restore Report Code Direct Address 0860 40Alarm Restore 1 (Zone Option) Direct Address 1228, 1328, 1428 & 1528 47 - 49Alarm Restore 3 (Zone Option) Direct Address 1236, 1336, 1436 & 1536 47 - 49Alarm Supervisory Report Code Direct Address 0871 41Alarm Telco 1 (Zone Option) Direct Address 1227, 1327, 1427 & 1527 47 - 49Alarm Telco 3 (Zone Option) Direct Address 1235, 1335, 1435 & 1535 47 - 49Ambush Report Code Direct Address 0900 41Ambush (Keypad Option) Direct Address 2440-2446 54Ambush User Code Direct Address 0495 36Answering Machine P/U W/O Line Seizure Direct Address 2417 51Area Output Turns Off Upon Disarm Direct Address 2700-2733 58Area System Trouble Reporting Options Direct Address 1120-1137 46Auto Bell Test On Arming Direct Address 2418 51Auto Disarm Rearm Delay Direct Address 4083 36Auto Download Id No. Direct Address 1023 38Auto Reset (Zone Option) Direct Address 1219, 1319, 1419 & 1519 47 - 49Auto Reset After Burg. Output Timeout Direct Address 2418 51Auto-Bypass (Zone Option) Direct Address 1204, 1304, 1404 & 1504 47 - 49Auto-Bypass Re-Entry (Zone Option) Direct Address 1207, 1307, 1407 & 1507 47 - 49Automatic Interior Bypass Direct Address 2421 52Aux. Output Access Control Timeout Direct Address 2402 35Aux. Output Chirp On Keyfob Arming Direct Address 2421 52Aux. Output Timeout Direct Address 2401 36Auxiliary KP Report Code Direct Address 0903 41Auxiliary Relay (Zone Option) Direct Address 1215, 1315, 1415 & 1515 47 - 49Backup Report On Telco 2 Direct Address 1027 41Burg. Alarm Output (Zone Option) Direct Address 1211, 1311, 1411 & 1511 47 - 49Burg. Alarm Output Timeout Direct Address 2403 36Bus Failure Report Code Direct Address 0872 41Bypass Faulted Zones Direct Address 2417 51Callback Telephone No. Select Direct Address 1022 38Callback Telephone Number 1 Direct Address 0600-0619 38Callback Telephone Number 2 Direct Address 0625-0644 38Cancel Next Test Timer On Any Report Direct Address 1027 41Cancel Report Code Direct Address 0859 40Cancel Window Time Direct Address 4082 36Central Station Receiver 1 Account Number Easy Menu Driven N/A 7Central Station Receiver 1 Format Easy Menu Driven N/A 8Central Station Receiver 1 Telephone Number Easy Menu Driven N/A 7Chime (Zone Option) Direct Address 1221, 1321, 1421 & 1521 47 - 49Chime On E4 Lug Direct Address 2420 52Chime Timeout Direct Address 2407 35Clear Dealer Program Direct Address 4091 60Closing Report Code Direct Address 0864 40Closing Report Only On Cond. Closing (Auto-Byp.) Direct Address 2417 51Cold Start Direct Address 4093 60Conditional Closing Report Code Direct Address 0865 40CS Receiver 1 Format Direct Address 0525 37CS Receiver 1 Options Direct Address 0526 37CS Receiver 1 Telephone Number Direct Address 0527-0546 38CS Receiver 2 Format Direct Address 0550 37CS Receiver 2 Options Direct Address 0551 37CS Receiver 2 Telephone Number Direct Address 0552-0571 38

Programm

ing Options Index

Page 72: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 72Pr

ogra

mm

ing

Opt

ions

Inde

xPROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER

CS Receiver 3 Format Direct Address 0575 37CS Receiver 3 Options Direct Address 0576 37CS Receiver 3 Telephone Number Direct Address 0577-0596 38CS System Report Options Direct Address 1027 41CS Telco 1 Subscriber Event Id Number Direct Address 0682-0713 39CS Telco 1 Subscriber Event Id Number (System) Direct Address 0714-0717 39CS Telco 1 Subscriber Opening/Closing Id Number ) Direct Address 0650-0681 39CS Telco 2 Subscriber Event Id Number Direct Address 0752-0783 39CS Telco 2 Subscriber Event Id Number (System) Direct Address 0784-0787 39CS Telco 2 Subscriber Opening/Closing Id Number Direct Address 0720-0751 39CS Telco 3 Subscriber Event Id Number Direct Address 0822-0853 40CS Telco 3 Subscriber Event Id Number (System) Direct Address 0854-0857 40CS Telco 3 Subscriber Opening/Closing Id Number Direct Address 0790-0821 40CS User Reporting Codes Direct Address 1030-1081 43Day Zone Open (Zone Option) Direct Address 1224, 1324, 1424 & 1524 47 - 49Day Zone Short (Zone Option) Direct Address 1225, 1325, 1425 & 1525 47 - 49Dealer Security Code Direct Address 0500-0502 36Digital Dialer Test Report Code Direct Address 0890 41Disable Answering-Machine Download Direct Address 2419 51Disable Auto Dial Tone Detection Direct Address 4084 53Disable Auto Status Direct Address 2421 52Disable Auto-Reset On Day Zone Direct Address 2419 51Disable Auto-Unbypass On Disarming Direct Address 2417 51Disable Callback Download Direct Address 2419 51Disable Closing Reports Per Area Direct Address 1025 41Disable Code Required For Easy Bypass Direct Address 2420 52Disable Code Required For Func. Mode Lvl. 1 Direct Address 2420 52Disable Exit/Entry Urgency Tone Direct Address 2422 52Disable Fire Reset (Area 1) Direct Address 2415 51Disable Fire Reset (Area 2) Direct Address 2415 51Disable Function-Mode Download Direct Address 2419 51Disable Keypad Instant Button Direct Address 2420 52Disable System Trouble Audible at Keypads Direct Address 2420 52Disable Opening Reports Per Area Direct Address 1024 41Disable Wait For Handshake Direct Address 1027 41Disable Wait For Silence Direct Address 1027 41Don�t Clear Aux. Relay With Arm/Disarm Direct Address 2421 52Download Security Code Direct Address 0645-0647 38Easy Arming Direct Address 2440-2454 54Enable Output Chirp on Keyfob Arm/Disarm Direct Address 2421 52Enable Burg. Output for Keyfob Chirp Direct Address 2422 52Enable Burg. Output Warning on Entry Direct Address 2418 51Enable Burg. Output on Telco Fail only when Armed Direct Address 2422 52Enable Day Zone Watch (Area 1) Direct Address 2416 51Enable Day Zone Watch (Area 2) Direct Address 2416 51Enable Exit-Delay Restart Direct Address 2419 51Enable Line-Fault Test Direct Address 2420 52Enable Manager�s Mode Direct Address 2418 51Enable Reporting To PC Preset Direct Address 2417 51Enable Smoke Detector Dirty Trouble Direct Address 2422 52Enable User Code By Area Direct Address 2500-2547 55Enable Zone Number On Pulse Alarm Direct Address 0526, 0551 & 0576 37Enter Date Easy Menu Driven N/A 12Enter Time Easy Menu Driven N/A 13Enter User Codes Easy Menu Driven N/A 9Enter Zone Descriptions Easy Menu Driven N/A 12Entry Delay 1 Direct Address 0001 35Entry Delay 2 Direct Address 0002 35Entry/Exit 1 (Zone Option) Direct Address 1216, 1316, 1416 & 1516 47 - 49Entry/Exit 2 (Zone Option) Direct Address 1217, 1317, 1417 & 1517 47 - 49

Page 73: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 73PROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER

Exit Delay Direct Address 0000 35Exit/Entry Follower (Zone Option) Direct Address 1218, 1318, 1418, . . ., 2318 47 - 49EZM Group Options Direct Address 2600-2605 56EZM Pgm Armed Terminal Control Direct Address 2622-2627 56EZM Tamper Report Code Direct Address 0876 41Fail To Close Report Code Direct Address 0868 40Fail To Open Report Code Direct Address 0869 40Fire KP Reporting Code Direct Address 0902 41Fire (Zone Option) Direct Address 1275, 1375, 1475, . . ., 2375 47 - 49Fire Alarm Verification (Zone Option) Direct Address 1276, 1376, 1476, . . ., 2376 47 - 49Fire Output (Lug E9) Direct Address 1213, 1313, 1413, . . ., 2313 47 - 49Fire Output Cadence Direct Address 2422 52Fire Output Timeout Direct Address 2405 36Global System Trouble Reporting Options Direct Address 1082-1116 45Handshake For Local Telemetry Direct Address 1027 41Include Sel./Grp. Bypass In Cond. Closing Status Direct Address 2417 51Interior 1 Normally Bypassed Direct Address 2419 51Interior Bypass (Zone Option) Direct Address 1262, 1362, 1462, . . ., 2362 47 - 49Key Fob Transmitters Easy Menu Driven N/A 12Keypad Area Assignment Direct Address 2425-2439 54Keypad Auxiliary Direct Address 2440-2454 54Keypad Fire Direct Address 2440-2454 54Keypad Options Direct Address 2440-2454 54Keypad Panic Direct Address 2440-2454 54Keypad Sounder On Alarm Direct Address 1264, 1364, 1464, . . ., 2364 47 - 49Keyswitch Arming Direct Address 1206, 1306, 1406, . . ., 2306 47 - 49Leading Digits For Pager Format (1st Digit) Direct Address 0520 37Leading Digits For Pager Format (2nd Digit) Direct Address 0521 37Local Or Central Station Reporting System Easy Menu Driven N/A 6Memory Failure Report Code Direct Address 0873 41Never Arm (Zone Option) Direct Address 1209, 1309, 1409, . . ., 2309 47 - 49No EOL Resistor (Zone Option) Direct Address 1239, 1339, 1439, . . ., 2339 47 - 49No. Rings Before Pickup Direct Address 4089 38Number Of RF Receivers Direct Address 3776 59Number Of Zones & Keypads Per Area Easy Menu Driven N/A 6,7Opening Report Code Direct Address 0866 40Opening After Alarm Reporting Code Direct Address 0867 40Opening Report Only After Alarm Report Direct Address 2417 51Panel AC Failure Report Code Direct Address 0875 41Panel Access Direct Address 2440-2454 54Panel Access Code Direct Address 0490-0492 36Panel Low Battery Report Code Direct Address 0874 41Panic KP Report Code Direct Address 0901 41Power-Up Delay (Zone Option) Direct Address 1223, 1323, 1423, . . ., 2323 47 - 49Pre-Alarm Warning (Zone Option) Direct Address 1208, 1308, 1408, . . ., 2308 47 - 49Priority (Zone Option) Direct Address 1202, 1302, 1402, . . ., 2302 47 - 49Priority Arming/Areas 1-2 Direct Address 2650-2651 57Priority With Bypass (Zone Option) Direct Address 1203, 1303, 1403, . . ., 2303 47 - 49Program Change Report Code Direct Address 0894 41Pulse Alarm Output Timeout Direct Address 2404 36Pulsed Alarm Output (Zone Option) Direct Address 1212, 1312, 1412, . . ., 2312 47 - 49Rem. Acc. Only Direct Address 2440-2454 54Remote Access Logging Direct Address 3184 57Reset Day Zone With Arm/Disarm Only Direct Address 2419 51Reset Output Timeout Direct Address 2400 36Reset Relay (Zone Option) Direct Address 1214, 1314, 1414, . . ., 2314 47 - 49Resound On Wireless Smoke Low Battery Direct Address 2419 51RF Receiver Tamper Report Code (system) Direct Address 0896 41RF Receiver Trouble Report Code (system) Direct Address 0895 41RF Transmitter Low Battery Report Code (zone) Direct Address 3879 52RF Transmitter Supervisory Report Code (zone) Direct Address 3880 52RF Transmitter Tamper Report Code (zone) Direct Address 3881 52RF Supervisory Timers Direct Address 3760-3775 59RF Transmitter Points Easy Menu Driven N/A 11RF Trouble Report Code Direct Address 0897 41Selective Bypass (Zone Option) Direct Address 1205, 1305, 1405, . . ., 2305 47 - 49Sensor Watch Report Code Direct Address 0877 41

Programm

ing Options Index

Page 74: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 74PROGRAMMING OPTION PROGRAM MODE ADDRESS LOCATION PAGE NUMBER

Sensor Watch (Zone Option) Direct Address 1240, 1340, 1440, . . ., 2340 47 - 49Sensor Watch Delay Direct Address 4088 35Service Message Report Code Direct Address 0893 41Single Digit Only Direct Address 0526,0551 & 0576 37Start Exit Delay After Ringback Direct Address 2418 51Status Report (Auto-Byp. Zones On Clos.) Direct Address 2417 51Sum Check Direct Address 0526,0551 & 0576 37Supervised Alarm Output Direct Address 2422 52Suppress �Bypass� Reminder When Armed Direct Address 2418 51Swinger Shutdown (Zone Option) Direct Address 1220, 1320, 1420, . . ., 2320 47 - 49Tamper Report Code Direct Address 0904 41Telco Answering Service Overide Direct Address 2421 52Telco Fail Only When Armed Direct Address 2420 52Telco Line Failure Direct Address 0880 41Telephone Dialing Prefix Direct Address 3882 - 3901 53Telephone Line Test Delay Direct Address 2414 35Test Timer Report Code Direct Address 0870 41Touchtone Dialing Only Direct Address 1027 41Touchtone Dialing W/Rotary Backup Direct Address 1027 41Transmit �402� Opening/Closing Code Direct Address 1027 41Trouble Report Code Direct Address 0861 40Trouble On Night Open Direct Address 1243, 1343, 1443, . . ., 2343 47 - 49Trouble On Open (Zone Option) Direct Address 1241, 1341, 1441, . . ., 2341 47 - 49Trouble On Short (Zone Option) Direct Address 1242, 1342, 1442, . . ., 2342 47 - 49Trouble Restore Direct Address 0862 40Trouble Restore 1 (Zone Option) Direct Address 1230, 1330, 1430, . . ., 2330 47 - 49Trouble Restore 3 (Zone Option) Direct Address 1238, 1338, 1438, . . ., 2338 47 - 49Trouble Telco 1 (Zone Option) Direct Address 1229, 1329, 1429, . . ., 2329 47 - 49Trouble Telco 3 (Zone Option) Direct Address 1237, 1337, 1437, . . ., 2337 47 - 49Veri-Phone Zones Priority Over Alarms Direct Address 2421 52Veri-Phone Zones Trip Aux. Relay Direct Address 2421 52Veri-Phone Zones Trip Fire Output Direct Address 2421 52Wireless Smoke Low Battery Resound Direct Address 2422 52Zone Anding Group 1 (Zone Option) Direct Address 1254, 1354, 1454, . . ., 2354 47 - 49Zone Anding Group 2 (Zone Option) Direct Address 1255, 1355, 1455, . . ., 2355 47 - 49Zone Area 1 (Zone Option) Direct Address 1244, 1344, 1444, . . ., 2344 47 - 49Zone Area 2 (Zone Option) Direct Address 1245, 1345, 1445, . . ., 2345 47 - 49Zone Options - Zones 1 To 96 Direct Address 1200-2376 47 - 49Zones Report Code - Zones 1 to 96 Direct Address 0910-1005 42

Prog

ram

min

g O

ptio

ns In

dex

Page 75: Alarma GEM P3200

L NAPCO Security Systems X GEM-P3200 Programming Instructions

WI818D 8/00 !Page 75G

EM-P

3200

Wiri

ng D

iagr

amGEM-P3200 WIRING DIAGRAM

8.3

VDC

4 AH

, 6 A

H O

R 7

AH

R

CO

MP

UT

ER

IZE

D S

EC

UR

ITY

SY

ST

EM

GE

MIN

I

AR

ME

DS

TA

TU

S

SY

ST

EM

AR

ME

D0

1/0

1/9

7

12

:00

AM

12

4

3

56

78

90

A B C

DE F GN

EX

T/Y

ES

PR

IOR

/NO

AR

EA

GEM

-RP1

CAe

2(2

LIN

E LC

D K

EYPA

D)

Page 76: Alarma GEM P3200

X GEM-P3200 Programming Instructions L NAPCO Security Systems

WI818D 08/00! Page 76

NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrantsits products to be free from manufacturing defects inmaterials and workmanship for thirty-six months followingthe date of manufacture. NAPCO will, within said period,at its option, repair or replace any product failing tooperate correctly without charge to the original purchaseror user.

This warranty shall not apply to any equipment, or anypart thereof, which has been repaired by others,improperly installed, improperly used, abused, altered,damaged, subjected to acts of God, or on which any serialnumbers have been altered, defaced or removed. Sellerwill not be responsible for any dismantling or reinstallationcharges.

THERE ARE NO WARRANTIES, EXPRESS ORIMPLIED, WHICH EXTEND BEYOND THEDESCRIPTION ON THE FACE HEREOF. THERE IS NOEXPRESS OR IMPLIED WARRANTY OFMERCHANTABILITY OR A WARRANTY OF FITNESSFOR A PARTICULAR PURPOSE. ADDITIONALLY, THISWARRANTY IS IN LIEU OF ALL OTHER OBLIGATIONSOR LIABILITIES ON THE PART OF NAPCO.

Any action for breach of warranty, including but not limitedto any implied warranty of merchantability, must bebrought within the six months following the end of thewarranty period.

IN NO CASE SHALL NAPCO BE LIABLE TO ANYONEFOR ANY CONSEQUENTIAL OR INCIDENTALDAMAGES FOR BREACH OF THIS OR ANY OTHERWARRANTY, EXPRESS OR IMPLIED, EVEN IF THELOSS OR DAMAGE IS CAUSED BY THE SELLER'SOWN NEGLIGENCE OR FAULT.

In case of defect, contact the security professional whoinstalled and maintains your security system. In order toexercise the warranty, the product must be returned bythe security professional, shipping costs prepaid andinsured to NAPCO. After repair or replacement, NAPCOassumes the cost of returning products under warranty.NAPCO shall have no obligation under this warranty, orotherwise, if the product has been repaired by others,improperly installed, improperly used, abused, altered,damaged, subjected to accident, nuisance, flood, fire oracts of God, or on which any serial numbers have beenaltered, defaced or removed. NAPCO will not beresponsible for any dismantling, reassembly orreinstallation charges.

This warranty contains the entire warranty. It is the solewarranty and any prior agreements or representations,whether oral or written, are either merged herein or areexpressly cancelled. NAPCO neither assumes, nor

authorizes any other person purporting to act on its behalfto modify, to change, or to assume for it, any otherwarranty or liability concerning its products.In no event shall NAPCO be liable for an amount inexcess of NAPCO's original selling price of the product,for any loss or damage, whether direct, indirect,incidental, consequential, or otherwise arising out of anyfailure of the product. Seller's warranty, as hereinaboveset forth, shall not be enlarged, diminished or affected byand no obligation or liability shall arise or grow out ofSeller's rendering of technical advice or service inconnection with Buyer's order of the goods furnishedhereunder.

NAPCO RECOMMENDS THAT THE ENTIRE SYSTEMBE COMPLETELY TESTED WEEKLY.

Warning: Despite frequent testing, and due to, but notlimited to, any or all of the following; criminal tampering,electrical or communications disruption, it is possible forthe system to fail to perform as expected. NAPCO doesnot represent that the product/system may not becompromised or circumvented; or that the product orsystem will prevent any personal injury or property loss byburglary, robbery, fire or otherwise; nor that the product orsystem will in all cases provide adequate warning orprotection. A properly installed and maintained alarm mayonly reduce risk of burglary, robbery, fire or otherwise butit is not insurance or a guarantee that these events will notoccur. CONSEQUENTLY, SELLER SHALL HAVE NOLIABILITY FOR ANY PERSONAL INJURY, PROPERTYDAMAGE, OR OTHER LOSS BASED ON A CLAIM THEPRODUCT FAILED TO GIVE WARNING. Therefore, theinstaller should in turn advise the consumer to take anyand all precautions for his or her safety including, but notlimited to, fleeing the premises and calling police or firedepartment, in order to mitigate the possibilities of harmand/or damage.

NAPCO is not an insurer of either the property or safety ofthe user's family or employees, and limits its liability forany loss or damage including incidental or consequentialdamages to NAPCO's original selling price of the productregardless of the cause of such loss or damage.

Some states do not allow limitations on how long animplied warranty lasts or do not allow the exclusion orlimitation of incidental or consequential damages, ordifferentiate in their treatment of limitations of liability forordinary or gross negligence, so the above limitations orexclusions may not apply to you. This Warranty gives youspecific legal rights and you may also have other rightswhich vary from state to state.

NAPCO LIMITED WARRANTY