al bareq rating chart - jenganllc
TRANSCRIPT
RATING CHART - Al BAREQ
GENERATOR SET RATING1500 / 50Hz 1800 / 60Hz
1500 / 1800RPM
SwitchablekVA/kWPR
kVA/kW kVA/kWSTD
kVA/kWSTDPR
PERKINS ENGINE
CYL GOV DISPL.MODELNO MODEL
ALTERNATOR DIMENSIONS
MODEL
FUEL CONSUMPTION
@ 75 % LOAD IN LI / HR
Mecc.Alte
5.4
8.2
10.4
14.0
17.1
24.1
31.0
31.0
35.0
35.0
37.5
36.0
54.0
54.0
34.9 / 27.930 / 24 33 / 26.4 38.2 / 30.6 3L M/E (OP) 3.32 JGB0030 ECP28-VL/4A
53.1 / 42.545 / 36 49.6 / 39.7 58.7 / 46.9 3L M/E (OP) 3.33 JGB0045 ECO32-1L/4A
68.1 / 54.560 / 48 66 / 52.8 75.1 / 60.1 3L M/E (OP) 3.34 JGB0060 EC032-2L/4A
91.3 / 7380 / 64 88 / 70.4 100.3 / 80.3 4L M/E (OP) 4.45 JGB0080 ECP34-1S/4A
114.4 / 91.5101.4 / 81.4 111.9 / 89.6 126.5 / 101.2 4L ELEC.
ELEC.
M/E (OP)
4.46 JGB0100 ECP34-2S/4A
N/A150 /120 165 / 132 N/A 6L ELEC. 5.98 JGB0150 ECP34-2L/4A
197 / 156 219 / 175
N/A N/A
N/A N/A
500 / 400 563 / 450
844 / 675
N/AN/A
N/A
1364 / 1092 1500 / 1200
1510 / 1208 1669 / 1329
180 / 144 200 / 160 6L 6.69 JGB0180 ECO38-1SN/4
N/A200 / 160 220 / 176 N/A 6L M/E (OP) 710 JGB0200A ECO38-2SN/4
231 / 185200 / 160 220 / 176 253 / 200 6L ELEC. 8.711 JGB0200B ECO38-2SN/4
245 / 196228 / 182 250 / 200 270 / 216 6L ELEC. 8.712 JGB0225 ECO38-3SN/4
250 / 200 275 / 220 6L ELEC. 8.713 JGB0250 ECO38-1LN/4
313 / 250275 / 220 300 / 240 344 / 275 6L ELEC. 9.314 JGB0275 ECO38-2LN/4
300 / 240 330 / 264 6L
6L
6L
6L
6L
6L
6L
6L
8L
8L
12V (60˚)
16V (60˚)
16V (60˚)
12V (60˚)
12V (60˚)
ELEC. 12.515 JGB0300 ECO38-2LN/4
62.0
54.0
76.0
72.0
90.0
97.0
121.0
130.0
143.0
160.0
196.0
213.0
237.0
198.0
203.0
400 / 320
500 / 400
625 / 500
625 / 500
750 / 600
N/A
N/A
N/A
N/A
N/A
1253 / 1002
400 / 320
455 / 364
500 / 400
600 / 480
650 / 520
750 / 600
800 / 640
900/720
1022 / 818
1253 / 1002
1364 / 1092
1505 / 1204
1844 / 1476
2058 / 1646
450 / 360
500 / 400
550 / 440
660 / 528
700 / 560
825 / 660
900 / 720
1000/800
1125 / 900
1385 / 1108
1500 / 1200
1656 / 1325
2028 / 1622
2263 / 1811
438 / 350
687 / 550
563 / 450
687 / 550
825 / 660
938 / 750
1385 / 1108
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
ELEC.
12.5
45.8
61.1
61.1
45.8
45.8
30.5
30.5
22.9
22.9
18.1
18.1
15.2
15.2
17
18
19
20
21
22
23
24
25
26
27
28
JGB0400
JGB0450
JGB0500
JGB0600
JGB0650
JGB0750
JGB0800
JGB0900
JGB1000
JGB1250
JGB1360
JGB1500
29 JGB1840
30 JGB2058
HCI444F
PI734C
PI734E
PI734F
PI734B
PI734A
HCI634J
HCI634H
HCI634G
HCI634G
HCI544F
HCI544E
HCI544D
HCI544C
151 / 120.5136 / 109 150 / 120 165.5 / 132.5 6L 5.97 JGB0135
FUEL TANK
H WEIGHTL W
24.2 / 19.322.3 / 17.820.3 / 16.2 26.6 / 21.3 4L MECH. 2.2 4.8
1103A-33G
1103A-33TG1
1103A-33TG2
1104A-44TG2
1104C-44TAG2
1006TAG2
1106A-70TAG3
1106A-70TAG4
1306A-E87TAG3
1306A-E87TAG4
1306A-E87TAG6
1606A-E93TAG4
1606A-E93TAG5
2206A-E13TAG3
2506A-E15TAG2
2506A-E15TAG1
2806A-E18TAG1A
2806A-E18TAG2
4006-23TAG2A
4006-23TAG3A
4008-TAG1A
4008-TAG2A
4012-46TWG2A
4012-46TWG3A
4012-46TAG2A
4016TAG1A
4016TAG2A
1006TAG
404D-22G / 404A-22G1JGB00201 (ECO28-M/4) / (ECP28-M/4)
400 / 320 438 / 350350 / 280 400 / 320 6L ELEC. 12.516 JGB0350 ECO38-3LN/4
137
137
137
137
137
248
248
288
288
288
288
608
608
608
608
608
776
776
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
248
38
6082206A-E13TAG2
1300
1300
1300
1360
1360
1560
1560
1835
1835
1835
1835
1700
1700
2100
2500
3500
3500
2450
2450
2450
2350
2450
2350
2200
2200
2100
2100
1560
1700
1700
1700
2200
2200
2650
2650
2800
2800
2800
2800
3000
3000
3800
5000
6200
6200
4750
4750
4500
4500
4340
4340
4200
4200
4000
4000
2650
11851550 750
780
780
780
1040
1040
1090
1090
1140
1140
1140
1140
1240
1240
21003600
1350
1350
1350
1350
1600
1600
1950
1950
2050
2050
2200
2200
2200
2850
2850
1090ECP34-2L/4A
STAMFORD
1500 RPM/50Hz
987
1088
1122
1224
1389
1607
1828
1771
1771
1801
1891
3103
3103
3498
3756
3756
4693
4835
7500
7500
8419
8419
9993
9993
10750
13916
14200
1607
595
3243
The dimensions above are for standard open type range. The weight and dimensions may vary in case of enclosed type and if additional type and features are selected. Prime Power: Power available for unlimited running hours at variable load. Overload of %10 is permitted for 1 hour every 12 hour of operation.Standby Power: Power available at variable load in case of mains power failure. No overload is permitted.
This outline drawing gives dimension and demonstrative arrangement details only.
This data are indicative only and not to be used for installation design purpose. H
L W
mmLiterKg (Dry)Mecc-Alte Alternators9-350 kVAStamford Alternators400-2058 kVANot AvailableSwitchable engines must be requested at point of order
N/A