NIBE F2120 is an inverter-controlled air/water heat pump which represent a real breakthrough when it comes to efficiency. With a seasonal performance factor in excess of 5.0* , the heat pump provides more than five times as much heat per year as an electric heater with the same energy consumption. NIBE F2120 provides optimum savings since the heat pump automatically adapts to your home’s output requirements all year round. NIBE F2120 has a class leading working range and deliver a supply temperature of up to 65°C. Even at outdoor temperatures of as low as -25°C, it still provides a supply temperature of up to 63°C, while keeping the noise level to a minimum. NIBE F2120 has three-phase connection, which simplifies elec- trical installation. Thanks to smart technology, the product gives you control over your energy consumption and will be a key part of your connected home. The efficient con- trol system automatically adjusts the indoor climate for maximum comfort, and you do nature a favour at the same time. • Breakthrough in efficiency with a seasonal perform- ance factor of over 5.0.* • Class leading working range, supply temperature of up to 65°C, and 63°C at an outdoor temperature of -25°C. • Minimal noise level, even at full output. *NIBE F2120 has a rating of SCOP > 5.0 (Average climate, Low temperature) and SCOP 4.3 (Colder climate, Low temperature) in accordance with European standard EN 14825:2013, i.e. the standard for determining the reference seasonal performance factor, SCOP. Applies to F2120-16 and -20. IT'S IN OUR NATURE NIBE.EU Air/water heat pump NIBE F2120

Upload: others

Post on 09-Sep-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

NIBE F2120 is an inverter-controlled air/water heatpump which represent a real breakthrough when itcomes to efficiency. With a seasonal performancefactor in excess of 5.0* , the heat pump providesmore than five times as much heat per year as anelectric heater with the same energy consumption.NIBE F2120 provides optimum savings since theheat pump automatically adapts to your home’soutput requirements all year round.

NIBE F2120 has a class leading working range anddeliver a supply temperature of up to 65°C. Even atoutdoor temperatures of as low as -25°C, it stillprovides a supply temperature of up to 63°C, whilekeeping the noise level to a minimum. NIBE F2120has three-phase connection, which simplifies elec-trical installation.

Thanks to smart technology, the product gives youcontrol over your energy consumption and will be akey part of your connected home. The efficient con-trol system automatically adjusts the indoor climatefor maximum comfort, and you do nature a favourat the same time.

• Breakthrough in efficiencywith a seasonal perform-ance factor of over 5.0.*

• Class leading working range, supply temperatureof up to 65°C, and 63°C at an outdoor temperatureof -25°C.

• Minimal noise level, even at full output.

*NIBE F2120 has a rating of SCOP > 5.0 (Average climate, Low temperature) and SCOP 4.3 (Colder climate, Low temperature) in accordance with European standard EN 14825:2013, i.e. the standard for determining the reference seasonal performance factor, SCOP. Applies to F2120-16 and -20.

IT'S IN OUR NATURE NIBE.EU

Air/water heat pumpNIBE F2120

Page 2: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Installation method

F2120 – a part of your climate system where F2120 isintended to be combinedwith one of the indoormodulesVVM or the control modules SMO.

Together with an indoor module, F2120 creates a com-plete heating/cooling and hot water unit. Our flexibleindoor modules provide efficient heating and high hotwater performance. VVM indoor modules are completewith a smart and user-friendly control system, hot waterheater, additional heat, self-regulating circulation pump,etc.

The control modules, SMO, offer a flexible systemsolution that can be easily customised. For systemswith SMO, different components such as water heaters,additional heat and other accessories can be selectedto suit the installation's requirements. Up to eight F2120can be connected to a SMO 40.

There is a wide range of system solutions and accessor-ies for NIBE's indoor modules and control modules.

2 NIBE F2120

IT'S IN OUR NATURE

This is how NIBE F2120 works

Page 3: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

COMPATIBLE INDOOR MODULES (VVM) AND CONTROL MODULES (SMO)

SMO 40SMO 20VVM 500VVM 320VVM 310XXXXXF2120-8XXXXXF2120-12XXXXXF2120-16XXXXXF2120-20

INDOOR MODULES

LEK

APH

LEK

APH

VVM 225

UN

VVM 310VVM 310With integratedEMK 310

Part no. 069 084

Part no. 069 430

VVM 320Stainless steel,3x230 V

Part no. 069 113

VVM 320Stainless steel,1x230 V

Part no. 069 111

VVM 320Stainless steel,3x400 V

Part no. 069 109

VVM 320Enamel, 3x400 V

With integratedEMK 300

Part no. 069 110

VVM 500Part no. 069 400

VVM 320Copper, 3x400 V

Part no. 069 108

CONTROL MODULES

SMO 20

LEK

Control modulePart no. 067 224

SMO 40

LEK

Control modulePart no. 067 225

NIBE F2120 3

IT'S IN OUR NATURE

Page 4: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Principle of operationPrinciple of operation with hot water and a heating sys-tem.

The heating medium side and the domestic hot watersidemust be fitted with the necessary safety equipmentin accordance with the applicable regulations.

EXPLANATION

Indoor module (VVM 320)EB15

Heat pump (F2120)EB101Safety valve, heat pumpFL10Shut-off valveQM41FilterballQZ2Connection, heating medium out of F2120XL1Connection, heating medium in to F2120,XL2

-EB101

-XL2

-XL1

-QM1

-FL10

-QM40

-QZ2

-EB15

4 NIBE F2120

IT'S IN OUR NATURE

Page 5: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Transport and storageF2120 must be transported and stored vertically.

Ensure that the heat pump cannot fall over duringtransport.

Ensure that the heat pump cannot be damaged duringtransportation.

Installation andpositioning• Place F2120 outdoors on a solid level base that cantake the weight, preferably a concrete foundation. Ifconcrete slabs are used they must rest on asphalt orshingle.

• The lower edge of the evaporator must be at the levelof the average local snow depth. The concretefoundation or concrete plinths must therefore be atleast 70 mm high.

• F2120 should not be positioned next to noise sensitivewalls, for example, next to a bedroom.

• Also ensure that the placement does not inconveni-ence the neighbours.

• F2120 must not be placed so that recirculation of theoutdoor air can occur. This causes lower output andimpaired efficiency.

• The evaporator must be sheltered from direct wind / ,which negatively affects the defrosting function. PlaceF2120 protected from wind / against the evaporator.

• Small amounts of condensation water, as well as meltwater from defrosting, may be produced. Condensa-tion water must be led off to a drain or equivalent.

• Care must be exercised so that the heat pump is notscratched during installation.

LEK

F2120

min 300 mm

LEK

F2120

LEK

min70 mm

Do not place F2120 directly on the lawn or other nonsolid surface.

If there is a risk of snow slip from roof, a protective roofor cover must be erected to protect the heat pump,pipes and wiring.

NIBE F2120 5

IT'S IN OUR NATURE

Good to know aboutNIBE F2120

Page 6: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

LIFT FROM THE STREET TO THE SET UPLOCATIONIf the base allows, the simplest thing is to use a pallettruck to move the F2120 to the set up location.

The centre of gravity is offset to one side (see print onthe packaging).

LEK

C:a 180 kgApprox. 180 kg

If F2120 needs to be transported across soft ground,such as a lawn, we recommend that a crane is usedthat can lift the unit to the installation location. WhenF2120 is lifted with a crane, the packaging must be un-disturbed, see the illustration above.

If a crane vehicle cannot be used the F2120 can betransported on an extended sack truck. F2120 must betaken from its heaviest side and two people are requiredto lift F2120.

LIFT FROM THE PALLET TO FINALPOSITIONINGBefore lifting remove the packaging and the securingstrap to the pallet.

Place lifting straps around each machine foot. Liftingfrom the pallet to the base requires four persons, onefor each lifting strap.

Supplied componentsLocal differences in the enclosed kit may occur. Seerelevant installer manual for more information.

F2120-8, F2120-12

Filterball (G1").

LEK

LEK

2 x flexible pipes (DN25, G1")with 4 x gaskets.

F2120-16, F2120-20

Filterball (G1 1/4").

LEK

LEK

2 x flexible pipes (DN25, G11/4") with 4 x gaskets.

6 NIBE F2120

IT'S IN OUR NATURE

Page 7: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Installation areaThe distance between F2120 and the house wall mustbe at least 350 mm. Clearance above F2120 should beat least 1,000 mm. However, free space in front mustbe 1,000mm for future servicing.

35

0 m

m

Fritt utrymme bakom

Fritt utrymme framför dock 1000 mm för ev. framtida service

Min. avståndvid användningav flera F2300

600 mm

10

00

mm

400 mm

Minimalt fritt utrymme

600mm

Minimalt fritt utrymme

Minimum freespace

However, free space in front must be1000 mm for future servicing

Minimum free space

Minimum distance during useof several F2120

600 mm

600 mm

At least 1000mm

Free space behind350 mm

400 mm

NIBE F2120 7

IT'S IN OUR NATURE

Page 8: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Inspection of theinstallationCurrent regulations require the heating installation to beinspected before it is commissioned. The inspectionmust be carried out by a suitably qualified person andshould be documented. The above applies to closedheating systems.

If the heat pump is replaced, the installation must beinspected again.

Condensation watertroughThe condensation water trough collects and leads awaymost of the condensation water from the heat pump.

It is important for the heat pump’s function that thecondensation water is led away and that the outlet forthe condensation water pipe is positioned so as to pre-vent damage to the building. Condensation run-offshould be checked regularly, especially during the au-tumn. Clean if necessary.

Pipe with heating cable for draining the condensate drainpan is not included. To ensure this function, the access-ory KVR 10 should be used.

• The condensation water (up to 50 litres/24 hrs) thatcollects in the trough should be routed away by a pipeto an appropriate drain, it is recommended that theshortest outdoor stretch possible is used.

• The section of the pipe that can be affected by frostmust be heated by the heating cable to preventfreezing.

• Route the pipe downward from F2120.

• The outlet of the condensation water pipe must be ata depth that is frost free or alternatively indoors (withreservation for local ordinances and regulations).

• Use a water trap for installations where air circulationmay occur in the condensation water pipe.

• The insulation must seal against the bottom of thecondensation water trough.

RECOMMENDED ALTERNATIVE FORLEADING OFF CONDENSATION WATER

Stone caisson

LEK

Frostfritt djup

F2120

Frost proofdepth

If the house has a cellar the stone caisson must be po-sitioned so that condensation water does not affect thehouse. Otherwise the stone caisson can be positioneddirectly under the heat pump.

The outlet of the condensation water pipe must be atfrost free depth.

8 NIBE F2120

IT'S IN OUR NATURE

Installation

Page 9: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Drain indoors

Water seal

Joint

The condensation water is lead to an indoor drain (sub-ject to local rules and regulations).

Route the pipe downward from F2120.

The condensation water pipe must have a water seal toprevent air circulation in the pipe.

KVR 10 spliced as illustrated. Pipe routing inside housenot included.

Gutter drainage

LEK

F2120

Frostfritt

djupFrost freedepth

Water seal

The outlet of the condensation water pipe must be atfrost free depth.

Route the pipe downward from F2120.

The condensation water pipe must have a water seal toprevent air circulation in the pipe.

If none of the recommended alternatives is used goodlead off of condensation water must be assured.

NIBE F2120 9

IT'S IN OUR NATURE

Page 10: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Pipe installationPipe installation must be carried out in accordance withcurrent norms and directives.

F2120 can only operate up to a return temperature ofabout 55 °C and an outgoing temperature of about 65 °Cfrom the heat pump.

F2120 is not equipped with external shut off valves onthe water side; these must be installed to facilitate anyfuture servicing. The return temperature is limited bythe return line sensor.

WATER VOLUMESDepending on the size of F2120, an available watervolume is required to prevent short operating times andto enable defrosting. For optimal operation of F2120, aminimum available water volume of 10 litres times thesize number is recommended. E.g. F2120-12: 10 litresx 12 = 120 litres.

PIPE COUPLINGHEATINGMEDIUMCIRCUIT• The heat pump must be vented by the upper connec-tion (XL1) using the venting nipple on the enclosedflexible hose.

• Install the enclosed particle filter before the inlet, i.e.the lower connection (XL2) on F2120.

• All outdoor pipes must be thermally insulated with atleast 19 mm thick pipe insulation.

• Install shutoff and drain valves so that F2120 can beemptied in the event of prolonged power failures.

• The supplied flexible hoses act as vibration dampers.The flexible pipes are fitted so an elbow is created,thus acting as vibration damping.

Charge pumpThe charge pump (not included in the product) ispowered and controlled from the control module. It hasa built-in anti-freezing function and, for this reason, mustnot be switched off when there is a risk of freezing.

At temperatures below +2 °C the charge pump runsperiodically, to prevent the water from freezing in thecharge circuit. The function also protects against excesstemperatures in the charge circuit.

PRESSURE DROP, HEATING MEDIUM SIDE

F2120-8, -12, -16, -20

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

0 0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9

Tryckfall

[kPa]

Flöde [l/s]

Tryckfall F2120

Pressure drop(kPa)

Flow(l/s)

-12/-16/-20

-8

HEAT INSULATION

LEK

Heat insulation

10 NIBE F2120

IT'S IN OUR NATURE

Page 11: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

INSTALLING FLEX HOSESLEK

Data

Serie.nr.

Art.nr. 711453

OUT

IN

XL1

XL2

Connection, heating medium out of F2120XL1Connection, heating medium in to F2120,XL2

DOCKINGF2120 can be connected in several ways. The necessarysafety equipment must be installed in accordance withcurrent regulations for all docking options.

See nibe.eu for more detailed docking options.

Electrical connections• The heat pump must not be connected without thepermission of the electricity supplier and must beconnected under the supervision of a qualified electri-cian.

• If F2120 is fused with a miniature circuit breaker, itmust have at least motor characteristic ”C”. For MCBsize see "Technical Specifications".

• F2120 does not include an omnipolar circuit breakeron the incoming power supply. The heat pump’ssupply cable must be connected to a circuit breakerwith at least a 3 mm breaking gap. When the buildingis equipped with an earth-fault breaker, the heat pumpshould be equipped with a separate one. The earth-fault breaker should have a nominal tripping currentof no more than 30 mA. Incoming supply must be400V 3N~ 50Hz via electrical distribution units withfuses.

For 230V~ 50Hz, the incoming supply must be 230V~50Hz via distribution box with fuses.

• If an insulation test is to be carried out in the building,disconnect the heat pump.

• If the control is to be supplied separately from othercomponents in the heat pump (e.g. for tariff connec-tion), a separate operating cable must be connectedto terminal block (X5).

• The routing of cables for heavy current and signalsshould be made out through the cable glands on theheat pump's right-hand side, seen from the front.

• The communication cable must be a three core,shielded cable and be connected between F2120 ter-minal block X22 and the control module.

• Connect the charge pump to the control module. Seewhere the charge pump is to be connected in the In-staller Manual for your control module.

NIBE F2120 11

IT'S IN OUR NATURE

Page 12: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

When your heat pump is located outdoors some externalmaintenance is required.

Insufficient maintenance can cause serious damage toF2120, which is not covered by the guarantee.

Checking grilles andbottom panel onF2120Regularly check throughout the year that the grille is notclogged by leaves, snow or anything else.

You should be vigilant during windy conditions and/orin the event of snow as the grille can become blocked.

Also check that the drain holes in the bottom panel (ten)are free from dirt and leaves.

Regularly check that condensation is routed away cor-rectly through the condensation pipe. Ask your installerfor assistance if required.

KEEP FREE OF SNOW AND ICE

F2120 F2120

F2120 F2120

LEK

LEKLEK

LEK

Prevent snow from building up and covering the grilles and drain holeson F2120.

F2120 F2120

F2120 F2120

LEK

LEKLEK

LEK

Keep free of snow and/or ice.

12 NIBE F2120

IT'S IN OUR NATURE

Maintenance

Page 13: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Cleaning the outercasingIf necessary the outer casing can be cleaned using adamp cloth.

Care must be exercised so that the heat pump is notscratched when cleaning. Avoid spraying water into thegrilles or the sides so that water penetrates into F2120.Prevent F2120 coming into contact with alkaline cleaningagents.

NIBE F2120 13

IT'S IN OUR NATURE

Page 14: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

When connection to NIBE indoor module / controlmodule (VVM / SMO) is ready, you can control your unitvia the indoor module / control module.

Control, generalThe indoor temperature depends on several differentfactors. Sunlight and heat emissions from people andhousehold machines are normally sufficient to keep thehouse warm during the warmer parts of the year. Whenit gets colder outside, the climate system must bestarted. The colder it is outside, the warmer radiatorsand under floor heating system must be.

Control of the heat production is performed based onthe "floating condensing" principle, which means thatthe temperature level needed for heating at a specificoutdoor temperature is produced based on collectedvalues from the outdoor and supply temperaturesensors. The room sensor can also be used to com-pensate the deviation in room temperature.

Heat productionThe supply of heat to the house is regulated inaccordance with the heating curve setting se-lected. After adjustment, the correct amount

of heat for the current outdoor temperature is supplied.The supply temperature of the heat pump will oscillatearound the theoretically required value.

OWN CURVEF2120 has pre-programmed non-linear heating curves.It is also possible to create your own defined curve. Thisis an individual linear curve with a number of breakpoints. You select break points and the associatedtemperatures.

Hot water productionHot water charging starts when the temperat-ure has fallen to the set start temperature. Hotwater charging stops when the hot water

temperature at the hot water sensor has been reached.

For occasional higher hot water demand, there is afunction called "temporary lux" that allows the temperat-ure to be raised via one time increase or up to 12 hours(selected in the menu system).

It is also possible to set F2120 in holiday mode, whichmeans that the lowest possible temperature is achievedwithout the risk of freezing.

Additional heat onlyThe indoor module (VVM), which is connected to F2120,can be used with the additional heat alone (electricboiler) to produce heating and hot water, for examplebefore the outdoor module is installed.

ADDITIONAL HEAT ONLYThe indoor module (VVM), which is connected to F2120,can be used with the additional heat alone (electricboiler) to produce heating and hot water, for examplebefore the outdoor module is installed.

Alarm indicationsThe status lamp lights red in the event of an alarm andthe display shows detailed information depending onthe fault. An alarm log is created with each alarm con-taining a number of temperatures, times and operatingstatus.

14 NIBE F2120

IT'S IN OUR NATURE

Functions

Page 15: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

The displayThe indoor module (VVM) / control module (SMO) iscontrolled using a clear and easy to use display.

Instructions, settings and operational information areshown on the display. You can easily navigate betweenthe different menus and options to set the comfort orobtain the information you require.

The display unit is equipped with a USB socket that canbe used to update the software and save logged inform-ation in F2120.

Visit nibeuplink.com and click the "Software" tab todownload the latest software for your installation.

NIBE UplinkUsing the Internet and NIBE Uplink, you canobtain a quick overview and the present statusof the installation and the heating in your home.

You can obtain a good overall view, allowing you tomonitor and control the heating and hot water comforteffectively. If the system is affected by a malfunction,you receive an alert via e-mail that allows you to reactquickly.

NIBE Uplink also gives you the opportunity to controlthe comfort in your home easily, no matter where youare.

RANGE OF SERVICESYou have access to different levels of service via NIBEUplink. A basic level that is free and a premium levelwhere you can select different extended service func-tions for a fixed annual subscription fee (the subscriptionfee varies depending on the selected functions).

NIBE Uplink also available as an app from App Store andGoogle Play.

INSTALLATION AND ASSOCIATEDEQUIPMENT REQUIREMENTSThe following is required in order for NIBE Uplink tofunction with the installation:

• Network cable (straight, at least Cat 5E UTP).

• Internet connection.

• Web browser that supports JavaScript.

For further presentation, visit nibeuplink.com.

NIBE SMART PRICE ADAPTION™Smart Price Adaption is not available in allcountries. Contact your NIBE dealer for moreinformation.

Smart Price Adaption adjusts the heat pump's consump-tion according to the time of day that electricity pricesare lowest. This allows for savings, provided that thehourly rate subscription has been signed with the elec-tricity supplier.

The function is based on hourly rates for the coming daybeing downloaded via NIBE Uplink. To use the function,an Internet connection and account on NIBE Uplink arenecessary.

SMART HOMEWhen you have a smart home system that can commu-nicate with NIBE Uplink, you can control the installationvia an app by activating the “smart home” function.

By allowing connected units to communicate with NIBEUplink, your heating system becomes a natural part ofyour homesmart home and gives you the opportunityto optimise the operation.

Remember that the “smart home” function requiresNIBE Uplink in order to work.

NIBE F2120 15

IT'S IN OUR NATURE

Page 16: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Working areaF2120-8 working range

10

15

20

25

30

35

40

45

50

55

60

65

70

75

-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45

Framledningstemperatur

(°C)

Utomhustemperatur

(°C)

Arbetsområde F2120-8

Framledningstemperatur

Returledningstemperatur

Supply temperature(°C)

Supply temperature

Return temp

Outdoor temperature(°C)

F2120-12 working range

10

15

20

25

30

35

40

45

50

55

60

65

70

75

-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45

Framledningstemperatur

(°C)

Utomhustemperatur

(°C)

Arbetsområde F2120-12

Framledningstemperatur

Returledningstemperatur

Supply temperature(°C)

Supply temperature

Return temp

Outdoor temperature(°C)

F2120-16 / F2120-20 working range

Returledningstemperatur

Framledningstemperatur

10

15

20

25

30

35

40

45

50

55

60

65

70

75

-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45

Framledningstemperatur

(°C)

Utomhustemperatur

(°C)

Arbetsområde F2120-16 / F2120-20

Supply temperature(°C)

Supply temperature

Return temp

Outdoor temperature(°C)

F2120 working range cooling

510 20 30 4035 452515

10

15

20

25

30

35

Framledningstemperatur

(°C)

Utomhustemperatur

(°C)Returledningstemperatur

Framledningstemperatur

Supply temperature(°C)

Return temp

Supply temperature

Outdoor temperature(°C)

During shorter time it is allowed to have lower workingtemperatures on the water side, e.g. during start up.

16 NIBE F2120

IT'S IN OUR NATURE

Technical data

Page 17: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

HeatingOUTPUT AND COP AT DIFFERENT SUPPLYTEMPERATURESMaximum output during continuous operation.

F2120-8

F2120-8 max and min heating capacity

0

1

2

3

4

5

6

7

-25 -20 -15 -10 -5 0 5 10 15Utomhustemperatur

(°C)

F2120-8 Max och min uppvärmningskapacitet

Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

Uppvärmningskapacitet

(kW)Supply temperature(°C)

Supply temperature (35°C)Outdoor temperature

(°C)Supply temperature (45°C)Supply temperature (55°C)

F2120-8 COP

-25 -20 -15 -10 -5 0 5 10 15

F2120-8 COP

Utomhustemperatur

(°C)Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

0

1

2

3

4

5

6

COPSupply temperature(°C)

Outdoor temperature(°C)Supply temperature (35°C)

Supply temperature (45°C)Supply temperature (55°C)

F2120-12

F2120-12 max and min heating capacity

1

2

3

4

5

6

7

8

9

10

-25 -20 -15 -10 -5 0 5 10 15

F2120-12 Max och min uppvärmningskapacitet

Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

Utomhustemperatur

(°C)

Uppvärmningskapacitet

(kW)Supply temperature(°C)

Outdoor temperature(°C)Supply temperature (35°C)

Supply temperature (45°C)Supply temperature (55°C)

F2120-12 COP

0

1

2

3

4

5

6

7

-25 -20 -15 -10 -5 0 5 10 15

COP

Utomhustemperatur

(°C)Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

F2120-12 COP

Supply temperature(°C)

Supply temperature (35°C)Supply temperature (45°C)Supply temperature (55°C)

Outdoor temperature(°C)

NIBE F2120 17

IT'S IN OUR NATURE

Page 18: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

F2120-16

F2120-16 max and min heating capacity

2

4

6

8

10

12

14

-25 -20 -15 -10 -5 0 5 10 15

F2120-16 Max och min uppvärmningskapacitet

Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

Utomhustemperatur

(°C)

Uppvärmningskapacitet

(kW)Supply temperature(°C)

Supply temperature (35°C)Outdoor temperature

(°C)Supply temperature (45°C)Supply temperature (55°C)

F2120-16 COP

0

1

2

3

4

5

6

-25 -20 -15 -10 -5 0 5 10 15

COP

Utomhustemperatur

(°C)Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

F2120-16 COP

Supply temperature(°C)

Supply temperature (35°C)Outdoor temperature

(°C)Supply temperature (45°C)Supply temperature (55°C)

F2120-20

F2120-20 max and min heating capacity

2

4

6

8

10

12

18

16

14

-25 -20 -15 -10 -5 0 5 10 15

F2120-20 Max och min uppvärmningskapacitet

Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

Utomhustemperatur

(°C)

Uppvärmningskapacitet

(kW)Supply temperature(°C)

Supply temperature (35°C)Supply temperature (45°C)Supply temperature (55°C)

Outdoor temperature(°C)

F2120-20 COP

-25 -20 -15 -10 -5 0 5 10 15

F2120-20 COP

Utomhustemperatur

(°C)Framledningstemperatur (35 °C)

Framledningstemperatur (45 °C)

Framledningstemperatur (55 °C)

0

1

2

3

4

5

6

COPSupply temperature(°C)

Outdoor temperature(°C)Supply temperature (35°C)

Supply temperature (45°C)Supply temperature (55°C)

18 NIBE F2120

IT'S IN OUR NATURE

Page 19: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

CoolingOUTPUT AT DIFFERENT SUPPLYTEMPERATURES (COOLING)

F2120-8

1,0

1,5

2,0

2,5

3,0

3,5

4,0

4,5

5,0

5,5

6,0

15 20 25 30 35 40 45Utomhustemperatur

(°C)

F2120-8 Max och min kylningskapacitet

Framledningstemperatur (25 °C)

Framledningstemperatur (18 °C)

Framledningstemperatur (7 °C)

Kylningskapacitet

(kW)

25

18

7

25

18

7

Supply temperature(°C)

Supply temperature (35°C)Supply temperature (45°C)Supply temperature (55°C)

Outdoor temperature(°C)

F2120-12

1,0

2,0

3,0

4,0

5,0

7,0

6,0

15 20 25 30 35 40 45Utomhustemperatur

(°C)

F2120-12 Max och min kylningskapacitet

Kylningskapacitet

(kW)

Framledningstemperatur (25 °C)

Framledningstemperatur (18 °C)

Framledningstemperatur (7 °C)

25

18

7

25

18

7

Supply temperature(°C)

Supply temperature (35°C)Supply temperature (45°C)Supply temperature (55°C)

Outdoor temperature(°C)

F2120-16

2,0

3,0

4,0

5,0

6,0

10,0

9,0

8,0

7,0

15 20 25 30 35 40 45Utomhustemperatur

(°C)

F2120-16 Max och min kylningskapacitet

Kylningskapacitet

(kW)

Framledningstemperatur (25 °C)

Framledningstemperatur (18 °C)

Framledningstemperatur (7 °C)

25

18

7

25

18

7

Supply temperature(°C)

Supply temperature (35°C)Outdoor temperature

(°C)Supply temperature (45°C)Supply temperature (55°C)

F2120-20

1,0

2,0

3,0

4,0

5,0

6,0

11,0

10,0

9,0

8,0

7,0

15 20 25 30 35 40 45Utomhustemperatur

(°C)

F2120-20 Max och min kylningskapacitet

Kylningskapacitet

(kW)

Framledningstemperatur (25 °C)

Framledningstemperatur (18 °C)

Framledningstemperatur (7 °C)

25

18

7

25

18

7

Supply temperature(°C)

Supply temperature (35°C)Outdoor temperature

(°C)Supply temperature (45°C)Supply temperature (55°C)

NIBE F2120 19

IT'S IN OUR NATURE

Page 20: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

DimensionsF2120-8

F2120

1130

1055 40

Ø52

65 85470

35 -

65

1030 1

80

475

70

110

610

Ø40

F2120-12, -16, -20

F2120

1280

1205 40

Ø52

65 85470

35 -

65

1130 1

80

475

70

110

612

Ø40

20 NIBE F2120

IT'S IN OUR NATURE

Page 21: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Sound pressure levelsF2120 is usually placed next to a housewall, which givesa directed sound distribution that should be considered.Accordingly, you should always attempt when position-ing to choose the side that faces the least sound sens-itive neighbouring area.

The sound pressure levels are further affected by walls,bricks, differences in ground level, etc and shouldtherefore only be seen as guide values.

2 m

6 m

10 m

LEK

2016128F212053535353LW(A)Sound power level (LWA), according to EN12102 at 7 / 45 (nominal)

39393939dB(A)Sound pressure level (LPA) at 2 m*

29.529.529.529.5dB(A)Sound pressure level (LPA) at 6 m*

25252525dB(A)Sound pressure level (LPA) at 10 m*

* Free space.

NIBE F2120 21

IT'S IN OUR NATURE

Page 22: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

Technical data128F2120 – 1x230V

Heating

Output data according to EN 14511, partial load1)

7.35 / 2.43 / 3.025.17 / 1.72 / 3.00kW/kW/--7/35 Capacity / Power input / COPEN 14511

5.21/ 1.22 / 4.274.03 / 0.91 / 4.43kW/kW/-2/35 Capacity / Power input / COPEN 14511

5.27 / 1.49 / 3.544.07 / 1.16 / 3.51kW/kW/-2/45 Capacity / Power input / COPEN 14511

3.54 / 0.69 / 5.123.57 / 0.78 / 4.57kW/kW/-7/35 Capacity / Power input / COPEN 14511

3.64 / 0.91 / 4.003.66 / 0.98 / 3.74kW/kW/-7/45 Capacity / Power input / COPEN 14511

MaxMaxOutd. temp: / Supplytemp.

Cooling

4.69 / 1.70 / 2.763.80 / 1.28 / 2.9735 / 7 °COutput data according to EN 14511 ΔT5KCapacity/power input/EER 5.44 / 1.73 / 3.155.10 / 1.37 / 3.7335 / 18 °C

Electrical data

230V ~ 50HzRated voltage

1614ArmsMax operating current, heat pump

1513ArmsMax operating current, compressor

4540WMax output, fan

1616ArmsFuse

-Enclosure class

Refrigerant circuit

R410AType of refrigerant

2,088GWP refrigerant

ScrollType of compressor

2.62.4kgVolume

5.435.01tCO2-equivalent (The cooling circuit is hermetically sealed.)

Brine

3,4002,400m3/hMax airflow

-25 / 43°CMin/Max air temp, max

Heating medium

0.45 (4.5 bar)MPaMax system pressure heating medium

0.11 / 0.440.08 / 0.32l/sMin/Max flow

26 / 65°CMin/Max HM temp continuous operation

G1 1/4" external threadConnection heating medium F2120

G1 external threadConnection heating medium flex pipe

Miscellaneous

160150kgWeight (excl. packaging)

064 136064 134Part No.

22 NIBE F2120

IT'S IN OUR NATURE

Page 23: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

2016128F2120 – 3x400VHeating

Output data according to EN 14511, partial load1)

13.50/4.70/2.8710.13/3.33/3.047.35/2.43/3.025.17/1.72/3.00kW/kW/--7/35 Capacity / Power input / COPEN 14511

9.95/2.36/4.227.80/1.79/4.365.21/1.22/4.274.03/0.91/4.43kW/kW/-2/35 Capacity / Power input / COPEN 14511

10.41/2.88/3.617.97/2.24/3.565.27/1.49/3.544.07/1.16/3.51kW/kW/-2/45 Capacity / Power input / COPEN 14511

5.17/1.01/5.115.17/1.01/5.113.54/0.69/5.123.57/0.78/4.57kW/kW/-7/35 Capacity / Power input / COPEN 14511

5.49/1.33/4.145.49/1.33/4.143.64/0.91/4.003.66/0.98/3.74kW/kW/-7/45 Capacity / Power input / COPEN 14511

MaxMaxMaxMaxOutd. temp: / Supplytemp.

Cooling

8.10/3.50/2.317.09/2.72/2.614.69/1.70/2.763.80/1.28/2.9735 / 7 °COutput data according to EN 14511 ΔT5KCapacity/power input/EER 9.26/3.64/2.548.19/2.83/2.905.44/1.73/3.155.10/1.37/3.7335 / 18 °C

Electrical data

400V 3N ~ 50HzRated voltage

119.576ArmsMax operating current, heat pump

108.565ArmsMax operating current, compressor

80684540WMax output, fan

13101010ArmsFuse

-Enclosure class

Refrigerant circuit

R410AType of refrigerant

2,088GWP refrigerant

ScrollType of compressor

332.62.4kgVolume

6.266.265.435.01tCO2-equivalent (The cooling circuit is hermetically sealed.)

Brine

4,5004,1503,4002,400m3/hMax airflow

-25 / 43°CMin/Max air temp, max

Heating medium

0.45 (4.5 bar)MPaMax system pressure heating medium

0.19/0.750.15/0.600.11/0.440.08/0.32l/sMin/Max flow

0.480.380.350.27l/sMin flow defrosting (100 % pump speed)

26 / 65°CMin/Max HM temp continuous operation

G1 1/4" external threadConnection heating medium F2120

G1 1/4" external threadG1 external threadConnection heating medium flex pipe

Miscellaneous

183177167kgWeight (excl. packaging)

064 141064139064 137064 135Part No.

NIBE F2120 23

IT'S IN OUR NATURE

Page 24: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

SCOP & Pdesignh F2120 according to EN 148252016128F2120

SCOPPdesignhSCOPPdesignhSCOPPdesignhSCOPPdesignh5.05115.05114.8384.805.9SCOP 35 Average climate

(Europe)

3.912.33.912.33.788.33.756.3SCOP 55 Average climate(Europe)

4.25134.25134.059.34.036.8SCOP 35 Cold climate

3.53143.53143.339.83.337.4SCOP 55 Cold climate

5.5135.5135.489.25.435.9SCOP 35 Warm climate

4.5134.5134.489.24.356.3SCOP 55 Warm climate

1)Power statements including defrosting according to EN 14511 at heating medium supply corresponding to DT=5 K at 7 / 45.2)Nominal flow corresponds to DT=10 K at 7 / 45.

ENERGY RATING, AVERAGE CLIMATEF2120-20F2120-16F2120-12F2120-8ModelSMOSMOSMOSMOControl module model35 / 5535 / 5535 / 5535 / 55°CTemperature application

A++ / A++A++ / A++A++ / A++A++ / A++The product’s room heating efficiency class1)

A+++ / A+++A+++ / A+++A+++ / A+++A+++ / A+++Space heating efficiency class of the system2)

1Scale for the product’s room heating efficiency class A++ to G.2Scale for the system’s room heating efficiency class A+++ to G.

The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added tothe package, the overall efficiency of the package should be recalculated.

24 NIBE F2120

IT'S IN OUR NATURE

Page 25: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

AccessoriesDetailed information about the accessories and completeaccessories list available at nibe.eu.

Not all accessories are available on all markets.

Condensation water pipeCondensation water pipe, different lengths.

LEK

KVR 10-10 F21201 metresPart no. 067 549

KVR 10-30 F21203 metresPart no. 067 550

KVR 10-60 F21206 metresPart no. 067 551

NIBE F2120 25

IT'S IN OUR NATURE

Page 26: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,
Page 27: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,
Page 28: Air/waterheatpump NIBEF2120 f2120 tooteinfo.pdfEMK310 Partno.069084 Partno.069430 VVM320 Stainlesssteel, 3x230V Partno.069113 VVM320 Stainlesssteel, 1x230V Partno.069111 VVM320 Stainlesssteel,

NIBE Energy SystemsBox 14, SE-285 21 Markarydnibe.eu

PBDEN18

12-3

M11

996

This product sheet is a publication from NIBE Energy Systems. All product illustrations,facts and data are based on current information at the time of the publication’s approval.NIBE Energy Systems makes reservations for any factual or printing errors in this productsheet.

©2017 NIBE ENERGY SYSTEMS

WS name: -GemensamtWS version: a493 (working edition)Publish date: 2018-03-14 09:58