AIRSTAGETM OPTION
Specifications
UTD-GXTA-WARXD07/09/12/14GALHARXD07/09/12/14GATHARXD07/09/12/14LATHARXK07/09/12/14GCLHARXK07/09/12/14GALH
UTD-GXTB-WARXD18GALHARXD18GATHARXD18LATHARXK18GCLHARXK18GCLH
UTD-GXTC-WARXD24GALHARXD24GATHARXD24LATHARXK24GCLHARXK24GCLH
Net
Gross
Cooling
Heating
mm(inch)
kg(lb.)
°C (°F)
% RH
°C (°F)
Power source
Fixing of Auto Louver Grille
Extension Square Duct Limit
Net Dimension
(H x W x D)
Weight
Color
Louver Motor
Accessories
Operation Range
180x683x(84+9)[7-3/32 x 26-7/8 x (3-5/16+11/32)]
2.0 (4.4)
3.0 (6.7)
180 x 1083 x (84+9)[7-3/32 x 42-5/8 x (3-5/16+11/32)]
3.0 (6.7)
4.0 (8.9)
Connecting with Control box of indoor unit
Screw fixing to Flange or Square Duct
1.0m (Max. duct length between indoor unit and Grille)
180 x 883 x (84+9)[7-3/32 x 34-3/4 x (3-5/16+11/32)]
2.5 (5.6)
3.5 (7.8)
White
Stepping Motor
Fitting Flame, etc.
18 to 32 (64 to 90)
80% or less
16 to 30 (60 to 88)
*: The Auto Louver Grille Kit can also be installed to ARXD07/09/12/14/18/24LATH revision code B models. Please refer to the Design & Technical manual for ”revision code " details.
Model name
Applicable Indoor Unit
Closed louver
Opened louver
Flexible Control• Operation with indoor unit
Auto Louver can be operated by synchronizing remote controller of indoor unit.
• UP and Down auto swing• Auto airflow direction and auto swing• 4 steps selectable
• Auto-closing louverWhen operation of indoor unit is stopped, the louver will automatically close.
Controller Controller
Duct type
Wired Remote Wireles Remote
Auto Louver Grille
Dimensions
UTD-GXTA-W
W1 W2
683
883
1,083
645
845
1,045
180 148 9 84
Unit: mm
Model Name H1 H2 D1 D2
UTD-GXTB-W
UTD-GXTC-W
W1
W2
D2D1
H1 H2
Fitting Flame
Grille
ModelsUTD-GXTA-WUTD-GXTB-WUTD-GXTC-W
Auto Louver Grille Kit (Option)
Feature
145144
OPTIONAL PARTS LIST
AIRSTAGETM Option
Controllers / Interface
WiredRemoteController
WirelessRemoteController
CentralRemoteController
TouchPanelController
SystemController,SystemControllerLite
WirelessLANInterface
ExternalSwitchController
SimpleRemoteController
GroupRemoteController
AUXB07/09/12/14/18/24
GALHAUXB
07/09/12/14/18/24
GATH
4-wayCompact
AUXD18/24GALHAUXD18/24GATH
4-way
AUXA18/24/30/34/36/45/54GALH
AUXA30/34/36/
45/54GATH
AUXM018/024/030GLAH
Circular FlowMini
(With drainpump)
AUXK018/024/030/034/036/045/054GLAH
ARXD07/09/
12/14/18/24GALH
ARXD07/09/
12/14/18/24GATH
ARXD07/09/
12/14/18/24LATH
Slim(With drain
pump)
ARXK07/09/
12/14/18/24GCLH
Mini(Without
drainpump)
ARXK07/09/
12/14/18/24GALH
ARXA24/30/36/45GBTH
ARXA24/30/36/45GBLH
ARXA24/30/36/45LATH
MediumStatic
Pressure
ARXB07/09/
12/14/18/24/30/36/45GALH
ARXB24/30/36/45LATH
LowStatic
Pressure
ARXC36GBTH,
ARXC45/60GATH
High Static Pressure
ARXC72/90GBTHARXC72/90GATHARXC96GATH
AGYA007/009/012/014
GCAH
ASYA18/24GBCH
ASYA030/034
GTAH
ASYA18/24GACH
ASYA30GACH
ASYA18/24GATH
ASYA30GATH
Indoor unit
Cassette Duct
Floor
UTY-RNRYZ2
UTY-RLRY
UTY-RSRY, UTY-RHRY, UTY-RSKY, UTY-RHKY
UTY-LNHY
UTY-CGGY + UTY-VGGXZ1
UTY-DCGY
UTY-DTGYZ1
UTY-APGXZ1, UTY-ALGXZ1
UTY-TFSXZ1
FJ-RC-WIFI-1
FJ-RC-KNX-1i
FJ-RC-MBS-1
FJ-RC-MBS-1
FJ-RC-KNX-1i
FJ-RC-WIFI-1
UTY-VKSX
UTY-VKGX
UTY-VKSX
UTY-VKSX
UTY-VMSX
UTY-VMSX
UTY-VMGX
UTY-VMSX
UTY-TERX
UTY-
TFSXZ1
ABYA12/14/18/24GATH
Ceiling /Floor
ABYA30/36/45/54GATH
Ceiling
ASYA07/09GTAH
ASYA07/09GACHASYA07/09GATH
ASYA012/014
GACHASYA
012/014GATH
Wall Mounted
FJ-RC-MBS-1
FJ-RC-MBS-1
FJ-RC-KNX-1i
FJ-RC-KNX-1i
FJ-RC-WIFI-1
UTY-VKSX
UTY-VMSX
FJ-RC-WIFI-1
UTY-
TFSXZ1
UTY-
TFSXZ1
ControllersInterface
Others
IR Receiver Unit
HumanSensor Kit
RemoteSensor Unit
CassetteGrille
AutoLouverGrille Kit
Long LifeFilter
Flange
DrainPumpUnit
WidePanel
PanelSpacer
Fresh AirIntake Kit
Air OutletShutterPlate
Insulationfor HighHumidity
HalfConcealedKit
New amenity space can be offered by installing the Remote sensor.
UTG-UKYC-W
UTG-UKYA-B
AUXM018/024/030GLAH
AUXK018/024/030/034/036/045/054GLAH
High Static Pressure
Indoor unit
Cassette Duct
UTR-STA
AGYA007/009/012/014
GCAH
Floor
Others
Indoor unit 950600
Panel600
(mm)
(mm)
Panel spacer
242
For Compact Cassette
For Compact Cassette
For Cassette
For Compact Cassette type / Cassette type
For Cassette
Type Type
This kit is used to half conceal floor type indoor unit into the wall.
UTR-YDZK
UTZ-VXRA
UTG-BKXA-WUTG-BGYA-W
UTG-AKXA-WUTG-AGYA-W
UTD-GXTA-WUTD-GXTB-W(18)UTD-GXTC-W(24)
UTG-UGYA-W
UTY-LRHYB1
UTZ-KXRA
UTR-YDZK
UTZ-VXRA
UTG-BKXA-W
UTG-AKXA-W
UTG-UKYC-WUTG-UKYA-B
UTY-SHZXC
UTY-LBHXD
AUXB07/09/12/14/18/24
GALHAUXB
07/09/12/14/18/24
GATH
4-wayCompact
UTZ-KXGC
UTR-YDZB
UTZ-VXAA
UTG-UFYD-W
4-way
AUXD18/24GALHAUXD18/24GATH
UTZ-KXRA
Circular Flow
AUXA18/24/30/34/36/45/54GALH
AUXA30/34/36/
45/54GATH
UTZ-KXRA
ARXC36GBTH,
ARXC45/60GATH
UTD-LF60KA
UTG-UFYD-W
UTG-UGYA-W
2-wire type 3-wire type
KNX®Convertorfor Indoor Unit
KNX®Interface
MODBUS®Convertorfor Indoor Unit
MODBUS®Interface
KNX®Convertorfor VRF
MODBUS®Convertorfor VRF
UTD-
GXTA-WUTD-
GXTB-W(18)UTD-
GXTC-W(24)
UTY-XSZX
UTB-YWC
ARXD07/09/12/14/18/24GALH
ARXD07/09/12/14/18/24GATH
ARXD07/09/12/14/18/24LATH
Slim(With drain
pump)
Mini(With drain
pump)
ARXK07/09/
12/14/18/24GCLH
Mini(Without
drainpump)
ARXK07/09/
12/14/18/24GALH
UTZ-PX1NBA
UTD-LF25NA
UTD-LF25NA(24/30/36/45)
UTD-SF045TUTD-RF204(24/30/36/45)
UTZ-PX1BBA(07/09/12/14/18)
UTZ-PX1NBA(24/30/36/45)
UTD-SF045TUTD-
RF204
ARXA24/30/36/45GBTH
ARXA24/30/36/45GBLH
ARXA24/30/36/45LATH
MediumStatic
Pressure
ARXB07/09/
12/14/18/24/30/36/45GALH
ARXB24/30/36/45LATH
LowStatic
Pressure
ABYA30/36/45/54GATH
Ceiling
ABYA12/14/18/24GATH
Ceiling /Floor
UTR-DPB24T
UTD-RF204
ARXC72/90GBTHARXC72/90GATHARXC96GATH
147146
System Controller Lite System Controller SoftwareSoftware
Group Remote ControllerUTY-CGGY
Central Remote ControllerUTY-DCGY
For Centralized Control
Panels
For Cassette type
Cassette Grille
For Compact Cassette type
UTG-UFYC-W
UTY-ALGXZ1N E W UTY-APGXZ1N E W
N E W
Controllers
Simple Remote Controller
With operation modeUTY-RSRY
Wired Remote Controller (Touch Panel )
UTY-RNRYZ2N E W
IR Receiver UnitUTY-LRHYB1For Cassette type For Circular Flow Cassette type
For Individual Control
Wired Remote ControllerUTY-RLRY
Simple Remote Controller
Without operation modeUTY-RHRYN E W
IR Receiver UnitUTB-YWC For All Duct types
Wireless Remote ControllerUTY-LNHY
UTY-PLGXR2UTY-PLGXA2UTY-PLGXE2UTY-PLGXX2
Option
UTY-PEGXZ1
Option For Cassette type
Cassette GrilleUTG-UGYA-W
For Circular Flow Cassette type For Circular Flow Cassette type
Cassette GrilleUTG-UKYA-BN E W
Cassette GrilleUTG-UKYC-WN E W
Convertors / Adaptors
For External device
WHITE-USB-KEY(Software Protection Key)
BACnet® GatewayUTY-ABGXZ1
Software
MODBUS® InterfaceFJ-RC-MBS-1
N E W
Network Convertorfor LONWORKS®
UTY-VLGX
Wireless LAN InterfaceFJ-RC-WIFI-1
MODBUS® Convertor for VRF
UTY-VMGX
MODBUS® Convertor for Indoor UnitUTY-VMSX
KNX® Convertor
UTY-VKGXN E W
for VRFKNX® Convertor
UTY-VKSXN E W
for Indoor UnitKNX® InterfaceFJ-RC-KNX-1i
For System expansion
External Switch Controller
UTY-TERXN E W
Network Convertor
UTY-VTGXDC power supply type
for single splitNetwork Convertor
UTY-VTGXAC power supply type
for single splitNetwork Convertorfor Group Remote Controller
UTY-VGGXZ1
Signal Amplifier
UTY-VSGXZ1
OPTIONAL PARTS
AIRSTAGETM Option
Human Sensor KitUTY-SHZXCN E W
Touch Panel ControllerUTY-DTGYZ1N E W
UTY-PTGXA
Option
149148
For Ceiling type
For Ceiling type
Drain Pump UnitUTR-DPB24T
For Duct type
Flange (Round)UTD-RF204
Long-Life FilterUTD-LF60KAUTD-LF25NA
Flange (Square)UTD-SF045T
Auto Louver Grille Kit
For Medium Static Pressure Duct typeFor Medium Static Pressure Duct type / Ceiling type
For High Static Pressure Duct type
For Medium Static Pressure Duct type
Drain Pump UnitUTZ-PX1BBA
UTZ-PX1NBA
New amenity space can be offered by installing the Remote sensor.
For All Duct type
Remote Sensor UnitUTY-XSZX
For Low Static Pressure Duct type
For Medium Static Pressure Duct type
UTD-GXTA-W (for ARXD07/09/12/14, ARXK07/09/12/14)UTD-GXTB-W (for ARXD18, ARXK18)UTD-GXTC-W (for ARXD24, ARXK24)
For Slim Duct type / Mimi Duct type
For Cassette type
Panel spacer
50 mm
Indoor unit950
Panel 600
600 (mm)
For Cassette type
Panel Spacer
For Cassette type
Wide Panel UTG-AKXA-W UTG-BGYA-W
Insulation Kit
Insulation Kit for High Humidity
UTZ-KXRAUTZ-KXGC
For Cassette typeFor Compact Cassette type
Shuts the air outlet when only using as 3 blow out.
For Cassette type
Air Outlet Shutter PlateUTR-YDZK
Shuts the air outlet when only using as 3 blow out.
For Compact Cassette type
Air Outlet Shutter PlateUTR-YDZB
For Cassette type
UTZ-VXRA
For Compact Cassette type
* Not applicable for VRF V-III tropical series
Fresh Air Intake KitUTZ-VXAA
OPTIONAL PARTS
AIRSTAGETM Option
External Input and Output Function/External Connect Kit/Communication Kit
• : Dry Contact : Apply Voltage*2: Touch Panel Controller has these functions for Dry contact and Apply voltage, however, above External Connect Kit is not necessary because Touch Panel Controller has an external input terminal block.
UTY-XWZXZ6
UTY-XWZXZB
Communication systemOthers
External Connect Kit
For Indoor unit
UTY-XWZXZ7
UTY-XWZXZB
UTY-XWZXZC
UTY-XWZXZD
UTY-XWZXZE
For Outdoor unit
UTY-XWZXZ6
UTY-XWZXZ9
For RB unit For Central Remote Controller
UTY-XWZXZ7
UTY-XWZXZ8
UTY-XWZXZA
For Touch Panel Controller
UTY-XWZXZA
UTY-XWZXZF
All On / All Off
Batch Stop
Forced Stop
Emergency Stop
Forced Thermostat off
Operation Status
Error Status
Base Heater
Indoor Unit Fun Operation Status
Auxiliary Heater Output
Low Noise Mode Operation
Cooling/Heating Priority
Outdoor Unit Operation Peak ControlPower Usage Information fromElectricity Meter
Operation / Stop
Floor Ceiling / Floor Ceiling Wall Mounted
Indoor unit
4-way Compact,4-way,
Circular Flow
Cassette
Mini (With drain pump),Mini (Without drain pump),
Low Static Pressure,Slim (With drain pump),Medium Static Pressure,
High Static Pressure
Duct
AJY072/090/108/126/144/162
LA*BH
V-III
AJY072/090/108/126/144/162LN*BH
V-IIITropical
UTY-XWZXZD UTY-XWZXZB
UTY-XWZXZD UTY-XWZXZB
UTY-XWZXZD UTY-XWZXZB
UTY-XWZXZE UTY-XWZXZ7
UTY-XWZXZC
UTY-XWZXZC
UTY-XWZXZC
UTY-XWZXZC
UTY-XWZXZ6
Outdoor unit
AJYA072/090/108/
126/144LA*H
V-II
UTY-XWZXZ6
UTY-XWZXZ6
UTY-XWZXZ6
UTY-XWZXZ6
UTY-XWZXZ6
UTY-XWZXZF
UTY-XWZXZ9
UTY-XWZXZ6
FunctionInput
Output
Type
Controller
UTY-XWZXZA
UTY-XWZXZA
UTY-DCGY
Central RemoteController
UTY-XWZXZ7 UTY-XWZXZ8
UTY-XWZXZ7 UTY-XWZXZ8
UTY-DTGYZ1
Touch PanelController
*2
*2
*2
*2
*2
*2
For Floor type
Half Concealed KitUTR-STAThis kit is used to half conceal floor type indoor unit into the wall.
151150
For LARGE VRF
OPTIONAL PARTS
AIRSTAGETM Option
Specifications
Separation TubeUTP-AX054A
19.6 or less
UTP-AX090A
28.0 or less
UTP-AX180A
28.1 to 56.0
UTP-AX567A
56.1 or more
Model nameTotal cooling capacity of indoor unit (kW)
HeaderUTR-H0906LUTR-H0908L
28.0 or less
UTR-H1806LUTR-H1808L
28.1 to 56.0
3-6 Branches3-8 Branches
Model name
Total cooling capacity of indoor unit (kW)
Outdoor unit Branch kitUTP-CX567A (for V-II/V-III/V-III Tropical)
1
2
2 outdoor units
3 outdoor units
Model name
Number of outdoor unit
Separation Tube
UTP-AX180A UTP-AX567AUTP-AX054A UTP-AX090A
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
For DX-Kit
UTP-LX180A
Header
UTR-H0906L / UTR-H1806L UTR-H0908L / UTR-H1808L
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
Outdoor Unit Branch Kit
UTP-CX567A
Gas Pipe
Liquid Pipe
EV Kit
Model code 09 UTR-EV09XBModel code 12 UTR-EV14XBFor Compact Wall Mounted type
≦