airs science team meeting camp springs, 25-27 february 2003 holger vömel university of colorado and...
TRANSCRIPT
![Page 1: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/1.jpg)
AIRS science team meetingCamp Springs, 25-27 February 2003
Holger Vömel
University of Colorado
and NOAA/CMDL
Upper tropospheric humidity validation measurements
![Page 2: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/2.jpg)
Overview
• The NOAA/CMDL frost-point hygrometer
• Sample profile
• Available data
• Issues• Hygrometer
• Vaisala Humicap data
• Snow White
• Summary
![Page 3: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/3.jpg)
• Vertical Range:Lower troposphere to 28 km
• Sensitivity:Detection limit < 0.7 ppmvAccuracy : 10%
The NOAA frost-point hygrometer
![Page 4: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/4.jpg)
Frost-point hygrometer data
• Frost-point instruments measure frost-point temperature. We use a saturation vapor pressure formulation (Goff Gratch) to calculate vapor pressure, RH, mixing ratio etc.
• All data shown here are as relative humidity with respect to liquid water.
![Page 5: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/5.jpg)
Sample profile
Data files contain:
• Vaisala P + T
• Vaisala humicap RH
• Snow White FP temp
• NOAA FP temp
• ECC ozone mr
![Page 6: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/6.jpg)
Available data
Location Instruments # soundingsSan Cristóbal, Galapagos FP/O3/SW/PTU 2
San Cristóbal, Galapagos PTU 19
San Cristóbal, Galapagos* O3/PTU 4
Hilo, HI FP/O3/SW/PTU 7
Huntsville, AL ** FP/O3/SW/PTU 2
Boulder, CO FP/O3/SW/PTU 1
Sodankylä, Finland*** FP/O3/SW/PTU 2*) SHADOZ data **) Simultaneous BBAERI observations ***) SAGE III validation sounding
All data are located at: /dom/files/ops/correl/point/YYYY/MM/val_voem/
![Page 7: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/7.jpg)
Data issues: NOAA Hygrometer
Filtered data gaps :
• Gain change
• Mid level clear
• Frost-point controller not optimized for lower troposphere oscillations
![Page 8: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/8.jpg)
Data issues: NOAA Hygrometer
Hygrometer data files contain ascent and descent data.
Time stamp tells, whether the data are ascent or descent.
In some cases there are significant real differences between the ascent location and the descent location.
![Page 9: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/9.jpg)
Data issues: Vaisala humicap
Vaisala UTH issues:
• Two Humicap types:Humicap-H: Most common type Humicap-A: Old sensor (military still uses it)
• Time lag! Important at T < -40°C
• Contamination of the sensor. Important issue for sondes manufactured before 2002. New sensor protective cap introduced in 2001 improves this potential source of error.
• Dry bias (for humicap type-A). Only few of these sondes are sold Not an issue for AIRS validation measurements.
![Page 10: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/10.jpg)
The Meteolabor Snow White sonde
• Vertical Range:Lower troposphere to upper troposphere
• Accuracy: 0.1°C (company spec.)
![Page 11: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/11.jpg)
Data issues: Snow White low RH limit
Snow White may loose frost-coverage on the mirror
Loss of frost-point control
• May affect the entire profile
![Page 12: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/12.jpg)
Data issues: Snow White low RH limit
Snow White may loose frost-coverage on the mirror
Loss of frost-point control
• May affect the entire profile or shallow layers after the dry layer
• RH min ≥ 5-8 %
![Page 13: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/13.jpg)
Data issues: Dew vs. ice ambiguity
Humidity differences at low altitudes
![Page 14: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/14.jpg)
Data issues: Dew vs. ice ambiguity
Humidity differences at low altitudes
Due to the ambiguity of ice or dew coverage of the mirror
Need to use different vapor pressure curve
![Page 15: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/15.jpg)
Snow White upper tropospheric limit
Upper tropospheric limit depends on frost-point temperature
At TFP < -75°C the Snow White does no longer measure reliably
![Page 16: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/16.jpg)
• NOAA/CMDL frost-point hygrometer • measures accurately up to the middle stratosphere
• Few data gaps due to oscillations, mirror clear, gain change
•Vaisala humicap sensor• Assume only Vaisala Humicap-H is used
• Time lag is an important issue in the upper troposphere (T < -40°C)
• Contamination probably not a serious issue for newer sondes (new cap)
•Snow White• Has a lower limit of 5-8% RH
• Ambiguity of ice/dew T > -25°C
• Limit to tropospheric measurements with TFP > -75°C
•All data files have a field that contains the ‘Best MR’, which combines the best data from the three sensors into one field.
Summary
![Page 17: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/17.jpg)
NOAA/CMDL/MLO AIRS Validation
Mauna Loa Lidar, Water Vapor
0
2
4
6
8
10
12
14
16
0 25 50 75 100 125
Relative Humidity, Ice (%)
Alt
Ab
ov
e S
ea
Le
ve
l (k
m)
2002/10/11, clear
2002/10/2, cirrus 15 km
2002/9/9, cirrus 16 km
Three examples of water vapor observations, integration time 2 hours for Upper Trop, cirrus measured with lidar aerosol channels at 532 and 1064 nm.
![Page 18: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/18.jpg)
NOAA/CMDL/Mauna Loa Observatory Validation of AIRS for First Year
Proposed Actual
Water Vapor
Raman Lidar 14 17
Radiosonde 7 7
Frost-Point 5 for lidar calibration 2 for lidar calibration3 for AIRS Validation
Temperature
CMDL Radiosonde 7 7
Ozone
Ozonesonde 7 7
Temperature note: The NWS releases daily radiosondes at 2:00 AM and PM local time which measure accurate temperature profiles.
![Page 19: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/19.jpg)
PWV and Cloud Conditions
MLO Lidar, Water Vapor above 4.1 km
0
1
2
3
4
5
200 220 240 260 280 300 320 340
Julian Day
PW
V (m
m)
Clear
Subvisible Cirrus
Visible Cirrus
![Page 20: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/20.jpg)
SnowWhite - NOAA comparisons:Dry limit
![Page 21: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/21.jpg)
SnowWhite - NOAA comparisons:Dry limit
![Page 22: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/22.jpg)
Data issues: Humicap-A dry bias
![Page 23: AIRS science team meeting Camp Springs, 25-27 February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements](https://reader036.vdocuments.mx/reader036/viewer/2022062805/5697c0071a28abf838cc5d17/html5/thumbnails/23.jpg)
SnowWhite - NOAA comparisons:Dry limit