Presented by Project Department
Principles
Obstruction Clearance Limit
Clear line of Sight
Visibility
Landmark
Obstruction Clearance Limit
Criteria 1:7
1 unit height is allowed at 7 units distance from the center line of the runway.
1 unit - height
7 units - distance
R/W ¢
NPTIA Master Plan
Distance Between ATCT and Runway center line (exiting and future) is 800 m
Hence, maximum allowable ATCT height= 800 m ÷ 7 = 114.285 m
ATCT eye level(FAA, USA)Criteria
0.8 degree of line of sight angle incidence which allows ATCT personnel to achieve detection and recognition of object.ATCT eye level = D x tan 0.8 ; D ≈2500 m
= 34.9 m (reference: furthest r/w)
34.9 m is within the allowable height of 114.285 m.
Line of Sight clearance
Phase I
No hangers, cargo terminal buildings are obstructing the line of Sight
Line of Sight clearancePhase III – Ultimate Plan
Hangers, Cargo terminal buildings are in the course of line of Sight from ATCT to respective spots i.e. runways, taxiways and etc.
Line of Sight obstructions
Aircraft Type HeightAirbusA320 family 12.56 mA300 family 16.54 mA330 Family 17.4 mA380 24.1 m
Line of Sight obstructions
Aircraft Type HeightBoeing737 11.3 m757 13.6 m767 15.85 m747 19.4 mMD11 18 m
Line of Sight obstructions
Aircraft Type Height
ATR 42 7.59 mATR 72 7.65 mFokker F27, F28 8.7 m
Line of Sight obstructionsHangers….
For Airbus except A 380 25 mFor Boeing 30 mFor ATR and Fokker 16 m
Max. height could be considered as 30 m.
Line of Sight VS. Maximum Height
ATCT eye level34.9 m
Distance 2036m
Clear zone
2145m
2500m
Line of Sight VS. Maximum Height
Distance from Tower Clearance Height (m) (m)
1645 8.51145 17.0645 25.5285 30.0145 34.0
(Calculation based on 2036 m, the nearest spot.)
Clear Zone
20.35Clear Zone ATCT
taxiwayExisting runway
Future runway
Future runway
Clear zone
Landmark
Max ATCT height will be 38.9 m (34.9 m + 4 m (eye to roof top)
PTBATCT
ATCT can be viewed from 360 degree except from the direction of PTB since PTB is blocking the view.
ConclusionATCT Height 38.9 m could be considered.
The building (hanger, cargo, etc.) height to be limited not to obstruct line of sight between ATCT and respective spot.
If building height can not be limited for bigger aircraft hanger, such building to be located in the clear zone which is bounded by the straight lines from ATCT to two ends of nearest taxiways.
Q and A