air purifier selection guide duct mount models · which air purifier is the best choice for your...
TRANSCRIPT
120V YES
24VNO
YES
NO
120V
24V
COATED 14” LAMP WITH LARGE CATALYST SURFACE AREA FOR ODOR CONTROL. EXCELLENT IN HIGH HUMIDITY LOCATIONS. CAN BE MOUNTED IN DUCTING, DUCTBOARD OR OVER COIL IN AIR HANDLER/SUPPLY PLENUM. 2 YEAR LAMP REPLACEMENT CYCLE. 24V.
GERMICIDAL AIR PURIFIER WITH A SINGLE 18” LAMP WITH ODOR CONTROL VIA PHOTOCATALYTIC OXIDATION.
TWO HIGH OUTPUT UVC LIGHTS PRODUCE THE STRONGEST GERMICIDAL FIELD IN THE INDUSTRY, WHILE THE PCO PROCESS BREAKS DOWN ODORS.
ODOR CONTROL MODEL THAT USES SINGLET OXYGEN AND PHOTOCATALYTIC OXIDATION. 2 YEAR LAMP REPLACEMENT CYCLE. SUITABLE FOR OVER THE COIL OR DUCT MOUNT INSTALLATION.
HIGHEST UVC OUTPUT IN THE RESIDENTIAL HVAC INDUSTRY FEATURING TWO 18” LAMPS AND DUAL ODOR CONTROL VIA PHOTOCATALYTIC OXIDATION AND SINGLET OXYGEN. (SOS OPTION)
MODEL 2414 PREMIUMGFI #4901
MODEL 2018GFI #4918
MODEL 2000GFI #4919
MODEL 2124 - ZGFI #4904
MODEL 2000 - SOSGFI #4905
DISLIKE OR SENSITIVITY TO
RESIDUAL OZONE IN THE HOME?
YES
WHAT VOLTAGE
IS PREFERRED?
DO ANY OF THE RESIDENTS
SUFFER FROM ALLERGIES
OR ASTHMA?
IS THE HVAC SYSTEM
LARGER THAN 2.5T?
WHAT VOLTAGE
IS PREFERRED?
NO
THIS GUIDE IS FOR REFERENCE ONLY – INSTALLERS OR HOMEOWNERS MAY USE ANY DEVICE THEY SELECT.
* SINGLET OXYGEN CAN PRODUCE RESIDUAL OZONE THAT CAN CAUSERESPIRATORY IRRITATION AND SHOULD NOT BE USED IN THE PRESENCEOF INFANTS OR SENIORS. DEVICES THAT PRODUCE RESIDUAL OZONE DONOT EXCEED OSHA SAFETY LIMITS (.05 PPM) UNDER PROPER OPERATINGCONDITIONS – USE AT YOUR OWN RISK.
WHICH AIR PURIFIER IS THE BEST CHOICE FOR YOUR HOME?
DUCT MOUNT MODELSAIR PURIFIER
SELECTION GUIDEDISCLAIMER: THE HEALTH ASPECTS ASSOCIATED WITH THE USE
OF THIS PRODUCT AND ITS ABILITY TO AID IN DISINFECTION OF
ENVIRONMENTAL AIR HAVE NOT BEEN INVESTIGATED BY ETL.
Updated 2-2020
YES
NO
NO
SHIELDED 14” LAMP WITH LARGE CATALYST SURFACE AREA FOR ODOR CONTROL. EXCELLENT IN HIGH HUMIDITY LOCATIONS. CAN BE MOUNTED IN DUCTING, DUCTBOARD OR OVER COIL IN AIR HANDLER/SUPPLY PLENUM. 2 YEAR LAMP REPLACEMENT CYCLE.
USES PHOTOCATALYTIC OXIDATIONTECHNOLOGY FOR ODOR CONTROL WITHOUT RESIDUAL OZONE. IDEALLY INSTALLED ON FAN COIL HOUSING.
A 14” LAMP THAT USES UVC LIGHT TO KEEP COIL AND DRAIN PAN SURFACES CLEAN. SURROUNDING AIR DISINFECTION.
SPLICED LAMP TECHNOLOGY ANDPHOTOCATALYTIC OXIDATION FOR ODOR CONTROL. IDEALLY INSTALLED ON FAN COIL HOUSING.
A 14” DEVICE THAT USES SPLICED LAMP TECHNOLOGY FOR ODOR CONTROL.
WHICH AIR PURIFIER IS THE BEST CHOICE FOR YOUR HOME?
COIL
DUCT
YES
YES
DISLIKE OR SENSITIVITY TO
RESIDUAL OZONE IN THE HOME?
12”
14”
12”
14”
IDEAL LAMP LENGTH FOR
AIR HANDLER?
DISLIKE OR SENSITIVITY TO
RESIDUAL OZONE IN THE HOME?
YES
YES
NOLIFETIME
WARRANTY ON BALLAST?
IDEAL LAMP LENGTH FOR
AIR HANDLER?
WILL IT BE INSTALLED IN
DUCTWORK OR OVER THE COIL?
NO
DUAL ODOR CONTROL
PROTECTION?
IS ODOR CONTROL
IMPORTANT?
AIR PURIFIER
SELECTION GUIDE COIL CLEAN MODELS (24V)
MODEL 2414 - PREMIUMGFI #4901
MODEL 2414-FCGFI #4920
MODEL 2412-FCGFI #4922
MODEL 2414GFI #4925
MODEL 2414-O3GFI #4917
MODEL 2412-O3-FCGFI #4921
MODEL 2414-O3-FCGFI #4916
THIS GUIDE IS FOR REFERENCE ONLY – INSTALLERS OR HOMEOWNERS MAY USE ANY DEVICE THEY SELECT.
* SINGLET OXYGEN CAN PRODUCE RESIDUAL OZONE THAT CAN CAUSERESPIRATORY IRRITATION AND SHOULD NOT BE USED IN THE PRESENCEOF INFANTS OR SENIORS. DEVICES THAT PRODUCE RESIDUAL OZONE DONOT EXCEED OSHA SAFETY LIMITS (.05 PPM) UNDER PROPER OPERATINGCONDITIONS – USE AT YOUR OWN RISK.
NO MODEL 2124-ZGFI #4904
ODOR CONTROL MODEL THAT USES SINGLET OXYGEN AND PHOTOCATALYTIC OXIDATION. 2 YEAR LAMP REPLACEMENT CYCLE. SUITABLE FOR OVER THE COIL OR DUCT MOUNT INSTALLATION.