air ozonizers air ozonizers tÉcnica gs2 pr3 hw en.pdf · air ozonizers air ozonizers triozon range...
TRANSCRIPT
AIR OZONIZERS AIR OZONIZERS
TRIOZON RANGE
GS2/PR3
CODE MODEL PRODUCTION (mg.eq.O3/hr)
CONSUMPTION (W)
DIMENSIONS(mm)
WEIGHT(Kg)
GO-0250-05 TRIOZON GS2 75 20 345x320x141 2,9
GO-0250-08 TRIOZON PR3 200 24 345x320x141 3
1- Place in an elevated place, around 2 to 2.5m. Ozone is heavier than air and it tends to fall.
2- Take advantage of the natural currents of air in the room so that the ozone produced by the equipment covers the largest volume possible. The recommended place for the installation is on the lintel of a door, on a column, on a piece of furniture or closet, and on the opposite side of an extractor fan, window or strong current that can carried away the ozone to another unwanted place.
CALCULATION TABLE FOR THE GS2 /PR3 TRIOZON RANGEACCORDING TO THE SIZE OF THE ROOM
TYPE OF ROOMROOM VOLUME (m3)
40 60 80 100 150 200 250 300
Store GS2 GS2 GS2 GS2 GS2 PR3 PR3 PR3
Office PF2 PF2 PF2 GS2 GS2 GS2 PR3 PR3
Restaurant PR3 PR3 PR3 PR3 PR3 PR3 2 ud de PR3
2 ud de PR3
Retail GS2 GS2 GS2 GS2 PR3 PR3 PR3 PR3
Collective kitchen GS2 PR3 PR3 PR3 PR3 2 ud de PR3
2 ud de PR3
2 ud de PR3
Public restroom GS2 PR3 PR3 PR3 PR3 2 ud de PR3
2 ud de PR3
2 ud de PR3
Reception PF2 PF2 GS2 GS2 GS2 GS2 PR3 PR3
Warehouse in general GS2 GS2 GS2 GS2 PR3 PR3 PR3 PR3
14 21 28 36 54 71 90 107
APPROXIMATE SURFACE (m2)
INSTALLATION
• Room volume calculations based on a standard height of 2.80 m.• Data from the table are indicative, check with the technical department. • Any other application needs to be consulted.
TRIOZON’s most powerful model for regulated ozone dissemination.
For larger areas, 2 units of the PR3 model can be placed, and thus achieve greater volume.
PR3Shops, offices, restaurants and all kinds of public areas of various sizes have the GS2 as the most suitable TRIOZON equipment based on its dimensions.
GS2
A DIFFERENTTRIOZON OZONIZERFOR EACH TYPEOF PUBLIC SPACE
TRIOZON technology suitable for airtreatment of public areas up to 300 m3.
3- Place in an accessible place for mounting and easy dismantling.
4- NEVER install the equipment directly in the workplace or working station of a person.
5- ALL Ozone Generators must be in clean and ventilated areas.
Includes timer and forced ozone distribution by means of a fan.
TRIOZON RANGE GS2/PR3