Air-cooled Inverter Product Range. Updated by: Yap Boon Thiam Technical Engineer Email: [email protected] Date: 14/5/2012. Inverter Product Range. Contents: Product Range: Single Split Inverter (Series I) Single Split Inverter (Series II) Multi Split Inverter Inverter Control - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Air-cooled Inverter Product Range

Page 1

Air-cooled Inverter Product Range

Updated by:Yap Boon ThiamTechnical EngineerEmail: [email protected]: 14/5/2012

Page 2: Air-cooled Inverter Product Range

Page 2

Inverter Product Range

Contents:1. Product Range:

Single Split Inverter (Series I) Single Split Inverter (Series II) Multi Split Inverter

2. Inverter Control

3. Troubleshooting Guidelines

Page 3: Air-cooled Inverter Product Range

Page 3

Inverter Product Range

Single Split Inverter Series I

Page 4: Air-cooled Inverter Product Range

Page 4

Inverter Product Range

Single split Inverter Series I – A5LCY

Outdoor Indoor 10 15 20 25

A5LCY-CR

A5WMY-JR ○ ○ ● ●

A5WMY-LR ○ ○ ● ●

A5CKY-CR ○ ○ ● ○

A5CKY-ER ○ ○ ● ●

A5CMY-ER ○ ○ ● ●

A5CCY-CR ○ ○ ● ●

A5LCY-DR

A5WMY-JR ● ● ○ ○

A5CKY-CR ● ● ○ ○

A5CMY-ER ○ ● ○ ○

A5CCY-CR ● ● ○ ○

A5LCY-FR A5WMY-LR ● ● ○ ○

5WMY-JR

5CKY-ER

5CMY-ER

5CCY-CR

5WMY-LR

● Available

○ Not Available

Page 5: Air-cooled Inverter Product Range

Page 5

Inverter Product Range

Wall Mounted – A5WMY

A5WMY10/15JR A5WMY10/15LR

Vs

Item A5WMY-JR A5LCY-DR

A5WMY-LRA5LCY-FR

Cost Standard Cost effective

Compressor Rotary Hermetic swing

Weight 31 27

OD Dimension (HxWxD)

550x765x293 550x658x289

Outdoor fan speeds

6 2

Lowest ambient Cooling/Heating

-10/-15 10/-15

New

Page 6: Air-cooled Inverter Product Range

Page 6

Inverter Product Range

A5WMY-Features

High EER/COP performance.

ALL Models rank A/A or Exceeds!

High Quality & Efficiency DC Inverter compressor

5WMY JR Series LR Series

(W/W) EER COP EER COP

10 3.42 3.62 3.49 4.06

15 3.33 3.62 3.33 3.76

20 3.73 3.75 - -

25 3.30 3.74 - -

Page 7: Air-cooled Inverter Product Range

Page 7

Inverter Product Range

A5WMY-Features

BioPro IAQ.Protection 1Bio Antibody Filter-Able to eliminate up to 99.99% of various airborne infectious viruses-Deactivates influenza virus

Protection 2Titanium Apatite Filter-Dissolves odors and harmful airborne particles like dust, bacteria-Enhance photo catalytic capability

Note: Standard for LR series and Optional for JR series

Page 8: Air-cooled Inverter Product Range

Page 8

Inverter Product Range

A5WMY-Features

New Remote Control Turbo Mode- Fast cooling Quiet Mode

Error code diagnosis

ModelSound Pressure

(dBA)

5WMY10LR 21

5WMY15LR 22

GS02

Page 9: Air-cooled Inverter Product Range

Page 9

Inverter Product Range

A5LCY Series 1- Specification

Maximum piping length and elevation

ModelMax. total

piping length

(m)

Max. height difference

(m)

Pre-charge for up to piping length (m)

Additional charge

(g/m)

A5LCY10DR 15 10 7.5 20

A5LCY15DR 15 10 7.5 20

A5LCY10FR 20 10 7.5 20

A5LCY15FR 20 10 7.5 20

A5LCY20CR 30 10 7.5 20

A5LCY25CR 30 10 7.5 20

Page 10: Air-cooled Inverter Product Range

Page 10

Inverter Product Range

A5LCY Series I- Features

A5LCY-DR A5LCX-CR

Outdoor Control Box Made of plastic material More compact and lighter

New

Page 11: Air-cooled Inverter Product Range

Page 11

Inverter Product Range

A5LCY Series I- Features

Ease for Servicing Equipped with 7 segment display Able to retrieve error code and running parameter

Page 12: Air-cooled Inverter Product Range

Page 12

Inverter Product Range

A5LCY Series I- Features

A5LCY-Series I A5LCX-Series I

Outdoor coil Outdoor coil

Discharge pipe Discharge pipe

Outdoor ambient Outdoor ambient

Heat sink -

Heat sink thermistor to detect heat sink temperature

New

Thermistor

Page 13: Air-cooled Inverter Product Range

Page 13

Inverter Product Range

Single Split Inverter Series II

Page 14: Air-cooled Inverter Product Range

Page 14

Inverter Product Range

Single split Inverter Series II – A5LCY

● A5CMY62CR

●* A5CCY38CR

5CKY-ER

5CMY-ER

5CCY-CR

Outdoor Indoor 40 50 60

A5LCY-FRAvailable in

1Ø & 3Ø

A5CKY-ER ● ● ○

A5CMY-CR ○ ○ ●

A5CMY-ER ● ● ○

A5CCY-CR ●* ● ●

Outdoor Indoor

A5LCY28CR

A5CKY28ER

A5CMY28ER

A5CCY28CR

● Available

○ Not Available

Page 15: Air-cooled Inverter Product Range

Page 15

Improve sound level Equipped with a newly-developed turbo fan

4 selected fan speeds inclusive of Quiet mode

Inverter Product Range

Ceiling Cassette – A5CKY-ER Features

Sound Pressure Level (dBA) comparison

A5CKY-AR High Fan A5CKY-ER High Fan Silent Mode

20 42 20 34 27

25 45 25 37 30

28 49 30 41 32

40 51 40 44 36

50 53 50 47 41

Improved!

Page 16: Air-cooled Inverter Product Range

Page 16

Optimum air discharge

Multi comfort 3 air swing pattern

Inverter Product Range

Ceiling Cassette – A5CKY-ER Features

CK-A CK-E

Page 17: Air-cooled Inverter Product Range

Page 17

Modern and Elegant design Unique “Round” side contour Side LED light location Even air distribution Rotatable intake grill

Inverter Product Range

Ceiling Cassette – A5CKY-ER Features

Allow 90°RotationAllow 90°Rotation

A5CKY-ER

A5CKY-AR

Page 18: Air-cooled Inverter Product Range

Page 18

Compact Body Design

Inverter Product Range

Ceiling Cassette – A5CKY-ER Features

A B C

A5CKY20-50AR350mm

A5CKY20-28ER290mmA5CKY40-50ER325mm

Lower Height!

Model Dimension (mm)

A5CKY-ER A B C

20/25/28 265 290 340

40/50 300 325 275

Page 19: Air-cooled Inverter Product Range

Page 19

Built in high head drain pump 700mm drain head Water level switch is incorporated with drain pump to monitor its

water level

Inverter Product Range

Ceiling Cassette – A5CKY-ER Features

Page 20: Air-cooled Inverter Product Range

Page 20

Automatic air swing The motorized louver enables the air flow to be evenly distributed

Inverter Product Range

Ceiling Convertible– A5CMY Features

Maximum piping length and elevation

ModelMax. total

piping length(m)

Max. height difference

(m)

Pre-charge for up to piping length (m)

Additional charge(g/m)

A5LCY28CR 50 30 30 50

A5LCY40FR 75 30 30 50

A5LCY50FR 75 30 30 50

A5LCY60FR 75 30 30 50

Page 21: Air-cooled Inverter Product Range

Page 21

Optional drain pump Flexible installation at side 700mm drain head

Inverter Product Range

Ceiling Convertible– A5CMY Features

Page 22: Air-cooled Inverter Product Range

Page 22

Inverter Product Range

LED Indicator- A5LCY28CR

GreenA 1 2 3 4◑ ● ● ● ● 00 NORMAL

UA INSTALLATION ERROR

UH ANTIFREEZE (OTHER ROOMS)

◑ ● ● ● ○ L4 HEAT SINK OVERHEAT

◑ ● ● ○ ● L5 IPM ERROR / IGBT ERROR

◑ ● ● ○ ○ U0 INSUFFICIENT GAS

◑ ● ○ ● ○ E8 AC INPUT OVER CURRENT

◑ ● ○ ○ ● E6 COMPRESSOR START-UP ERROR

◑ ● ○ ○ ○ U7 COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND IPM PCB)

◑ ○ ● ● ● EA 4 WAY VALVE ERROR

◑ ○ ● ● ○ U2 DC VOLTAGE OUT OF RANGE

◑ ○ ● ○ ● E5 COMPRESSOR MOTOR LOCK / COMPRESSOR OVERLOADED

◑ ○ ● ○ ● F3 DISCHARGE PIPE OVERHEAT

◑ ○ ● ○ ○ A5 ANTIFREEZE (COOLING)

F6 HEAT EXCHANGER OVERHEAT

◑ ○ ○ ● ● H0 COMPRESSOR SENSOR SYSTEM ERROR

H6 COMPRESSOR FEEDBACK DETECTION ERROR

H8 AC CURRENT SENSOR ERROR

H9 OUTDOOR AIR THERMISTOR SHORT/OPEN

J3 COMPRESSOR DISCHARGE PIPE THERMISTOR SHORT / OPEN / MISPLACED

J6 OUTDOOR HEAT EXCHANGER THERMISTOR SHORT/ OPEN

J8 LIQUID PIPE THERMISTOR SHORT/ OPEN

J9 GAS PIPE THERMISTOR SHORT/OPEN

P4 HEAT SINK THERMISTOR SHORT / OPEN

◑ ○ ○ ● ○ L3 OUTDOOR CONTROL BOX OVERHEAT

◑ ○ ○ ○ ● E1 OUTDOOR PCB ERROR

◑ ○ ○ ○ ○ E7 OUTDOOR DC FAN MOTOR LOCK

DescriptionRedLED INDICATION

Page 23: Air-cooled Inverter Product Range

Page 23

Inverter Product Range

LED Indicator- A5LCY40/50/60FR

Page 24: Air-cooled Inverter Product Range

Page 24

Inverter Product Range

Multi Split Inverter

Page 25: Air-cooled Inverter Product Range

Page 25

Inverter Product Range

Multi-split Inverter – A5MSYOutdoor

Indoor Combination

1x 2x 3x 4x

A5MSY18BR(1 to 2)

10 10+10 - -

15 10+15 - -

A5MSY20BR(1 to 2)

10 10+10 - -

15 10+15 - -

20 10+20 - -

- 15+15 - -

- 15+20 - -

A5MSY25BR(1 to 3)

10 10+10 10+10+10 -

15 10+15 10+10+15 -

20 10+20 10+10+20 -

- 15+15 10+15+15 -

- 15+20 10+15+20 -

- 20+20 15+15+15 -

A5MSY30BR(1 to 4)

10 10+10 10+10+10 10+10+10+10

15 10+15 10+10+15 10+10+10+15

20 10+20 10+10+20 -

- 15+15 10+15+15 -

- 15+20 10+15+20 -

- 20+20 15+15+15 -

5WMY10/15/20JR

5CMY15/20ER

5CKY10/15/20CR

5WMY10/15LR

5CCY10/15/20CR

5CKY20ER

Page 26: Air-cooled Inverter Product Range

Page 26

Inverter Product Range

A5MSY18BR

Focus on residential market with 1 Bedroom + 1 Living Room More compact design and cost effective

Page 27: Air-cooled Inverter Product Range

Page 27

Inverter Product Range

A5MSY- Specification Maximum piping length and elevation

Page 28: Air-cooled Inverter Product Range

Page 28

Inverter Product Range

A5MSY- Features

Better Energy Saving Achieve class A/A based on European Energy Efficiency

Class ratings

Page 29: Air-cooled Inverter Product Range

Page 29

Inverter Product Range

A5MSY- Features

A5MSY-BR A5MSX-AR

Outdoor Control Box Made of plastic material More compact and lighter

Page 30: Air-cooled Inverter Product Range

Page 30

Inverter Product Range

A5MSY- Features

LED light error indicator (self error diagnosis)

Page 31: Air-cooled Inverter Product Range

Page 31

Inverter Product Range

A5MSY - Features

A5MSY-BR A5MSX-AR

Outdoor coil Outdoor coil

Discharge pipe Discharge pipe

Outdoor air Outdoor air

Gas pipe x no. of indoor unit Gas pipe x 1

Liquid pipe x no. of indoor unit Liquid pipe x 1

Heat sink -

New

More feedback (Thermistors) Outdoor unit has more feedbacks

New

New

Page 32: Air-cooled Inverter Product Range

Page 32

Inverter Product Range

A5MSY- Features Outdoor Fan Motor

Compressor and Expansion Device Has a higher EER, lower vibration & noise and higher durability

A5MSY-BR A5MSX-AR

Fan motor type Reluctance DC 3 Speeds AC

Lowest Operating Ambient

Cooling/Heating ( JC)0 / -16 19 / -9

A5MSY-BR A5MSX-AR

Compressor Swing type Scroll type

Expansion device EXV EXV

Page 33: Air-cooled Inverter Product Range

Page 33

Inverter Product Range

A5MSY - Features

Wiring Error Check Self corrected wiring connection just pressing a button (SW3)

After self-correction, OD will change the address in memory so that EXV A is link to Port B.

Note: Wire check correction need to be carried out again if wiring is changed or corrected

Page 34: Air-cooled Inverter Product Range

Page 34

Inverter Product Range

A5MSY - Features Priority Room Setting

Allow user to set a particular room which takes precedence over the operation mode of other rooms

For example, if Room A is the priority room, when COOL mode is selected in Room A while Room B, C & D are operating in the following mode:

Operation mode in Room B, C & D

Status for Room B, C & D

COOL or DRY or FAN Current operation mode is maintained

HEATThe unit enters Standby Mode. Operation resumes when Room A unit stops operating.

AUTO

If the unit is set to COOL mode, operation continues.

If set to HEAT mode, it enters Standby Mode.

Operation resumes when Room A unit stops operating.

Page 35: Air-cooled Inverter Product Range

Page 35

Inverter Product Range

A5MSY – Literatures

GS02 Handset Operating Manual

Manuals

Brochure

Installation Manual

Page 36: Air-cooled Inverter Product Range

Page 36

Inverter Products

Control

Page 37: Air-cooled Inverter Product Range

Page 37

Inverter Product Range

There are 5 operating modes:i. Cool mode

When Tr ≥ Ts - 1.5°C -Comp, ID Fan and OD Fan ON

When Tr ≤ Ts - 2°C ** -Comp and OD Fan OFF, ID Fan remain ON

**When room temperature falling below compressor cut off point even on the lowest operation frequency, compressor will stop operates.

Operating Mode

Time

Tr <= Ts - 2°CComp will stop

Lowest Freq

Tr = Room TemperatureTs = Set Temperature

Page 38: Air-cooled Inverter Product Range

Page 38

Inverter Product Range

There are 5 operating modes:ii. Heat mode

When Ts > Tr - 1.0°C -Comp, ID Fan and OD Fan ON

When Tr ≥ Ts + 1.5°C ** -Comp and OD Fan OFF, ID Fan remain at lowest speed if ID coil ≥ 27°C

**When room temperature rising above compressor cut off point even on the lowest operation frequency, compressor will stop operates.

Operating Mode

Time

Tr - Ts ≥ 1.5°CComp will stop

Lowest Freq

Tr = Room TemperatureTs = Set Temperature

Page 39: Air-cooled Inverter Product Range

Page 39

Inverter Product Range

There are 5 operating modes:iii.Fan mode

Only High, Medium and Low fan speeds are allowedChanging cool mode to fan mode; the compressor and outdoor fan will stop Compressor will only ON if the minimum stop time is > 3 minutes if the user change back to cool mode

Operating Mode

Page 40: Air-cooled Inverter Product Range

Page 40

Inverter Product Range

There are 5 operating modes:iv.Auto mode (for single split)

Mode switching point:Heating Cooling

Tr ≥ Ts + 2.5 Cooling Heating

Tr ≤ Ts – 2.5

During initial operationCooling operation: Tr > TsHeating operation: Tr < Ts

Operating Mode

Tr = Room TemperatureTs = Set Temperature

Page 41: Air-cooled Inverter Product Range

Page 41

Inverter Product Range

There are 5 operating modes:v. Auto mode (for multi split)

Without Priority Room Setting If more than 1 indoor is operating, priority is given to the first

unit that was turned on If a unit is turned on later to the same operating mode as

the first unit, the unit will operate as normal If a unit that are turned on later to the different operating

mode as the first unit, the units will enter Standby mode

With Priority Room Setting Unit operation subjected to Priority Room operating mode

Operating Mode

Page 42: Air-cooled Inverter Product Range

Page 42

Inverter Product Range

Communication between ID and OD Master by outdoor unit Indoor PCB transmits signal to outdoor PCB every 0.5s.

Outdoor unit will response to indoor once the valid data is received

If the data communication line between indoor and outdoor disrupted for 15s continuously; Compressor will stop, OD fan will stop with fan delay timer. ID LED starts blinking error

If the communication resumes within 15s; error code will be cleared and compressor restarts after 3 minutes

If the communication does not resume after 15s; unit unable to restart and ID LED continues to blink

Communication

Page 43: Air-cooled Inverter Product Range

Page 43

Inverter Product Range

To prevent frequent compressor ON/OFF and to allow pressure equalization The compressor will be on 3 minutes stand-by after

turning OFF before it is allowed to turn ONOD fan delay by Off timer to improve pressure

equalization and to prevent refrigerant from entering into evaporator

Minimum Run Control

Page 44: Air-cooled Inverter Product Range

Page 44

Inverter Product Range

Allow unit to automatically resume the same operating mode it was in before a power failure

Factory pre-set

Change over switching is only carried out during operation

Auto Restart

4 Way Valve Control

Operating mode 4-way valve is

Heat, except for defrost ON

Cool

Dry

Defrost

OFF

Page 45: Air-cooled Inverter Product Range

Page 45

Inverter Product Range

Defrost Cycle

During defrost 5LCY Series I 5LCY Series II 5MSY

Compressor ON ON ON

4-way valve OFF

EXV in operating room Fixed opening

EXV in non operating room - - Fixed opening

Outdoor fan OFF OFF OFF

Indoor fan OFF

Page 46: Air-cooled Inverter Product Range

Page 46

Inverter Product Range

Defrost Cycle- A5LCY Series I Condition for entering defrost Compressor minimum run time of 6 minutes; OR Compressor accumulated run time of 45 minutes if OD coil

< 3C When OD coil < 0C AND OD coil < OD air - 10C Condition for terminating defrost

OD coil > 12C; OR Total defrost timer of 650 seconds

Page 47: Air-cooled Inverter Product Range

Page 47

Inverter Product Range

Defrost Cycle- A5MSY Condition for entering defrost Compressor minimum run time of 6 minutes; OR Compressor accumulated run time > 38 minutes Based on OD coil temperature, output frequency & OD air

temperature Condition for terminating defrost

Minimum run time of 120 seconds; ANDDetermine based on OD ambient, in the range of 4C ≤

OD coil ≤ 12C; ORTotal defrost timer of 650 seconds

Page 48: Air-cooled Inverter Product Range

Page 48

Inverter Product Range

Indoor coil freeze prevention Outdoor fan control is carried out:

Only available in cooling mode When the indoor coil temperature < 2°C, the compressor

starts to drop the frequency This protection will cut in when:

Indoor coil temperature < 0°C for more than 180s.Compressor will stop, OD fan stop after 30s and indoor fan can only run at lowest fan speed

The unit can only be restarted after 3 minutes When the indoor coil temperature > 13°C, the

compressor frequency will be reset based on the OD ambient, room and set temperature

Page 49: Air-cooled Inverter Product Range

Page 49

Inverter Products

Troubleshooting Guidelines

Page 50: Air-cooled Inverter Product Range

Page 50

Inverter Product Range

From Indoor panelWhen error occurs, indoor LED display will start blinking continuously: Green lightThe blinking pattern does not indicate of error details The error details could be retrieved from handset

Error Indication

Page 51: Air-cooled Inverter Product Range

Page 51

Inverter Product Range

Error Indication

From Wireless Handset (GS02) Retrieve error code (steps)i. Hold down On Timer Cancel or Off Timer Cancel

for 5 seconds until “ ” indication flashes on the handset temperature display section

ii. Press again On Timer Cancel or Off Timer Cancel repeatedly until ID buzzer produces a long beep means there is error occur. Error code will be indicates on the display (refer error code table in the manual)

iii. If it is a short beep or two consecutive beeps, indicates No Error on the unit

iv. To cancel error code display, press On Timer Cancel or Off Timer Cancel for 5 seconds or leave the button not press for 1 minute

Page 52: Air-cooled Inverter Product Range

Page 52

Inverter Product Range

From Wireless Handset (GS02) Retrieve last state error (steps)i. Remove battery from the handset and put it in back

ii. Immediately press Mode and On/Off button together until “ “ is being

displayed

iii. Press Mode button until 5:00 is displayed

iv. Press On/Off button once

v. Repeat step (i)

vi. Repeat steps retrieve error code above

Error Indication

ON/OFF button Mode

button

Page 53: Air-cooled Inverter Product Range

Page 53

Inverter Product Range

From Wired controller Netware 3C “ “ and error code will be displayed on the last 2 digits

of the clock display Retrieved last state memory by pressing Sleep and Timer Active together and the error will be displayed

Error Indication

Page 54: Air-cooled Inverter Product Range

Page 54

Normal operation

From Outdoori. A5LCY Series I: 7 segment display When there is no error, compressor running frequency

is displayed When there is error, it flashes the error code

Inverter Product Range

Error Indication

Flashing error code

Page 55: Air-cooled Inverter Product Range

Page 55

From Outdoori. A5LCY Series I: 7 segment display (con’t) Could also retrieve unit operating condition

i. Press the tact switch, the 7 segment will start to flash from “00”. Press again, it will show “ 01” and subsequent running number

shows the parameter numberii. In split second without pressing the tact switch, parameter measurement of the

particular code above will be displayed

Inverter Product Range

Error Indication

Page 56: Air-cooled Inverter Product Range

Page 56

Inverter Product Range

From Outdoorii. A5LCY28CR: 5 LED light indicator

GreenA 1 2 3 4◑ ● ● ● ● 00 NORMAL

UA INSTALLATION ERROR

UH ANTIFREEZE (OTHER ROOMS)

◑ ● ● ● ○ L4 HEAT SINK OVERHEAT

◑ ● ● ○ ● L5 IPM ERROR / IGBT ERROR

◑ ● ● ○ ○ U0 INSUFFICIENT GAS

◑ ● ○ ● ○ E8 AC INPUT OVER CURRENT

◑ ● ○ ○ ● E6 COMPRESSOR START-UP ERROR

◑ ● ○ ○ ○ U7 COMMUNICATION ERROR (OUTDOOR CONTROL PCB AND IPM PCB)

◑ ○ ● ● ● EA 4 WAY VALVE ERROR

◑ ○ ● ● ○ U2 DC VOLTAGE OUT OF RANGE

◑ ○ ● ○ ● E5 COMPRESSOR MOTOR LOCK / COMPRESSOR OVERLOADED

◑ ○ ● ○ ● F3 DISCHARGE PIPE OVERHEAT

◑ ○ ● ○ ○ A5 ANTIFREEZE (COOLING)

F6 HEAT EXCHANGER OVERHEAT

◑ ○ ○ ● ● H0 COMPRESSOR SENSOR SYSTEM ERROR

H6 COMPRESSOR FEEDBACK DETECTION ERROR

H8 AC CURRENT SENSOR ERROR

H9 OUTDOOR AIR THERMISTOR SHORT/OPEN

J3 COMPRESSOR DISCHARGE PIPE THERMISTOR SHORT / OPEN / MISPLACED

J6 OUTDOOR HEAT EXCHANGER THERMISTOR SHORT/ OPEN

J8 LIQUID PIPE THERMISTOR SHORT/ OPEN

J9 GAS PIPE THERMISTOR SHORT/OPEN

P4 HEAT SINK THERMISTOR SHORT / OPEN

◑ ○ ○ ● ○ L3 OUTDOOR CONTROL BOX OVERHEAT

◑ ○ ○ ○ ● E1 OUTDOOR PCB ERROR

◑ ○ ○ ○ ○ E7 OUTDOOR DC FAN MOTOR LOCK

DescriptionRedLED INDICATION

Page 57: Air-cooled Inverter Product Range

Page 57

Inverter Product Range

From Outdoorii. A5LCY40/50/60FR: LED light indicator

Page 58: Air-cooled Inverter Product Range

Page 58

From Outdooriii. A5MSY20/25/30BR: 5 LED light indicator

Inverter Product Range

Error Indication

Page 59: Air-cooled Inverter Product Range

Page 59

Resistance value: 10k @ 25degC All indoors except A5WMY-LR A5LCY-10/15DR, 20/25CR

Inverter Product Range

Thermistor resistance table

Page 60: Air-cooled Inverter Product Range

Page 60

Resistance value: 20k @ 25degC A5WMY10/15LR MLCY10/15FR A5LCY-Series II

Except discharge sensor

A5MSY

Inverter Product Range

Thermistor resistance table

Page 61: Air-cooled Inverter Product Range

Page 61

For A5LCY-Series IIdischarge sensor

Inverter Product Range

Thermistor resistance table

Page 62: Air-cooled Inverter Product Range