  • Quickly identify and repair leaking tubes across the water box using specially designed tools

    No need to remove the outer plate of the water box

    QA system certified to ISO-9001

    Can be supplied under ANSI N45.2, 10CFR50 Appendix B

    PATENTED REPAIR PRODUCTS FOR AIR COOLED HEAT EXCHANGERS

  • EST Group | DC8017 2/10

    AIR COOLED HEAT EXCHANGER REPAIR PRODUCTS

    Identifying leaking tubes in an air cooled heat exchanger has always been a

    difficult task, due to the configuration of the finned tubes. Often, when tubes

    failed in the middle of a bundle, it was nearly impossible to verify the leaking

    tube. The G-150 pneumatic tube testing gun set allows tubes to be quickly

    tested and identified for plugging. The G-150 tube testing guns are easy to

    operate. After attaching a channel head extension, which allows the test guns

    to operate outside the water box, simply insert both the air injection gun and

    plugging gun into the tube ends, and press the air control valve, expanding

    the seals on both guns and pressurizing the tube. Any reduction of pressure

    indicated on the large pressure gauge will reveal even the smallest tube leak.

    Traditional tube plugging methods in air cooled heat exchangers involved

    tacking a rod to a tapered pin and beating the pin into the tube end. The rod

    was then shaken to break it free from the tapered pin. Tapered pins are not only

    unreliable, they can turn into lethal projectiles that can pose a real safety hazard

    for your workers. Resistant to thermal cycling and able to provide a seal thats

    helium-leak tight, EST Groups patented CPI Pop-A-Plug installs using

    controlled force. This protects against damage to tubesheet ligaments and

    adjacent tubesheet joints. The CPI Pop-A-Plug takes only seconds to install.

    Air cooled heat exchangers often experience excessive wear and tube failures

    at the tube inlets. However, once fluid enters the tube and becomes linear

    (usually within one foot of the tube end), the remainder of the failed tube is

    actually in good condition. EST Groups Hydra-Loc tube sleeving service is the

    perfect life-extension process for this application. Utilizing a thin walled sleeve

    that matches the material of the damaged tube, EST Field Service personnel

    bridge over the damaged area of the tube, using our Hydra-Loc tube sleeve

    expansion system. This process not only extends the operational life of tubes, it

    can also recover plugged tubes, and bring them back into service.

    Tube Testing - G-150 Test Gun Set

    Tube End Repair - Hydra-Loc Tube Sleeving

    Tube Plugging - CPI Pop-A-Plug

    Let our trained field service technicians help you!

    We have the experience and know-how to handle even

    the most demanding jobs safely, competently, and on-time.

    EST GroupHatfield, PA 19440 USA(P) 215.721.1100 800.355.7044(F) [email protected]://estgroup.cwfc.com

    EST Group B.V.Hoorn 312a2404 HL Alphen aan den RijnThe Netherlands(P) +31.172.418841(F) [email protected]

    EST Group Asia35 Tannery Road, #11-10 Tannery BlockRuby Industrial ComplexSingapore 347740(P) +65.6745.8560(F) [email protected]

    Gulf Coast Rental and Sales3201 N. Highway 146, Suite BBaytown, TX 77520 USA(P) 281.422.6073 800.355.7044(F) [email protected]