air conditioners lineup€¦ · the heat load varies greatly depending on the time and season....

80
Fuji Furukawa Engineering & Construction Co.Ltd. AIR CONDITIONERS LINEUP SPLI T / MULTI SPLIT

Upload: others

Post on 22-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

Fuji Furukawa Engineering & Construction Co.Ltd.

AIR CONDITIONERS LINEUP

SPLIT/MULTI SPLIT

Page 2: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

002

High Efficiency

CORE TECHNOLOGY

Optimized Inverter Control

Pursuit of Seasonal Efficiency

IPM*: Intelligent Power Module

In addition, the voltage is raised at the start of operation and fast comfort is attainable by more powerful operation.

Temp.

SettingTemp.

Time

I-PAM Inverter

Conventional Inverter

Over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity. We focused on high seasonal efficiency by all DC inverter control and high efficiency technology.

I-PAM (IPM*+PAM) inverter controlI-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance.

V-PAM (Vector + I-PAM) inverter controlV-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency, and better performance are attained.

HighHigh

CO

PC

OP

(%)(%)Heating part loadHeating part load

2525 5050 7575 100100

Frequent operation range

Conventional inverter control

I-PAM inverter control

More compact than conventional models Vector I-PAM

It becomes more powerful with the newly developed high efficient compressor motor control.

Page 3: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

003

All DC Inverter Technology

High Efficiency Heat Exchanger

DC twin rotary compressorThe high efficiency DC inverter type "2-cylinder rotary compressor" is used for our product ranges. It has achieved higher energy efficiency compared with similar compressors by optimizing the structure inside the compressor.

DC fan motorDC fan motor produces high power, wide operation range, and high efficiency.

Sine-wave DC inverter controlHigh efficiency operation is realized by using a sine wave DC inverter control.

High density multi-path heat exchangerHeat exchange performance is substantially improved by thin and high-density heat exchanger and multi-path efficiency technology.

High performance sub-cool heat exchangerHigher performance achieved by mounting of counter type bypass circuit. (Large multi type, VRF)

Compressor capacity

Com

pres

sor e

ffici

ency

Min. Max.

High Wide high efficiency range !

High efficiency impactson seasonal efficiency

Ø5 mm

20 mm

Refrigerant

Multi-path (image)

Multi-path heat exchanger

Lambda heat exchanger

Sub-coolerHeat exchanger

In case of cooling circuit

Indoor unitOutdoor unit

Compressor

Heat exchanger

Wide high efficiency rangeDC twin rotary compressor

Page 4: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

004

Energy Saving Control

CORE TECHNOLOGY

Economy operationLimits the maximum operation current, and the power consumption is cut down and the maximum load is suppressed.

+2°C *Max. 30°CCooling / Dry

Heating

-4°C *Max. 16°C

Saving operation

Set temp.

Set temp.

Human sensor

SAVE !AUTO

RESTART

Normal operation Normal operation

Judgment(Over 20 min.)

Human sensor coverage

90° 100°

6 m 6 m

Smart Operation

Time

Economy operation

Normal operationSetting

temperature

Human sensor control Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to the previous operating mode.

Page 5: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

005

Room temperature set point limitationThe minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.

Auto-off timer• The indoor unit is turned off

automatically when it reaches to the preset operating time frame.

• The time frame of the "Auto off timer" can be flexibly scheduled.

• Off time can be set from 30 to 240 minutes.Normal Time

ON

8 17 24

Over Time

ONOFF Auto OFF

Set interval time (17:00–24:00)

1 hour 1 hour

ON Auto OFF

Example: At interval time hour (17:00–24:00) to prevent forgetting to turn off Set off time : 1 hour

Set temperature auto return • The setting temperature automatically

returns to the previous setting temperature.

• The time range in which the set temperature can be changed is 10 to 120 minutes.

Capacity save operationOperation capacity can be set in 5 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed.

Time

Capacity

Settinglevel

Capacity saveSettingrange

100%

80%

60%

40%

0%

Setting temp.

Cooling operation

24°C22°C

Set temperature change Auto return

Time

Settable time range10 to 120 minutes

Setting temp.

Heating operation

25°C

23°C

Set temperature change Auto return

11:40 13:40 Time

Settable time range10 to 120 minutes

Normal set temp. range Limit set temp. range

30°C

10

Page 6: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

006

Comfort Performance

CORE TECHNOLOGY

Hea

ting

capa

city

(kW

)

Ambient temperature (°C)

High

-7 High

Keeping rated capacity

High heating capacity is realized even at low outdoor temperature by mounting a large heat exchanger or large DC rotary compressor and developing high performance inverter PCB

Powerful Heating

All DC inverter technology

By All DC inverter control, electricity loss is decreased and power consumption is substantially reduced.

High efficiencyDC Fan motor

DC Rotary compressor

High density heat exchanger

High-density 5-mm thin tube diameter heat exchanger mounted. Capacity is enlarged including sub heat exchanger. Heat exchange efficiency substantially improved.

Ø5-mm

Making the tube thin:

Heat exchanger volume

About 35% UP! comparing previous model

Sub heat exchanger

Page 7: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

007

Quick Comfort

Auto changeover functionAt Auto setting, the cooling / heating mode is automatically switched according to the set temperature and room temperature.

Outdoor unit low noise operationUsers can choose low noise levels, depending on the installation environment. The operation time can be set using the timer.

Comfort airflowPrecision wind direction control is realized and ventilation efficiency is also improved by 3 technologies. Our airflow control makes your environment more comfortable.

10°C Heat operationWhen you leave, minimum heating operation is performed to maintain the room temperature. (Maintained at 10°C)

Powerful operationContinuous operation by maximum airflow and maximum compressor speed after a certain period of time allows the temperature to reach the setting temp. quickly.

Cooling operationHeating operation

Cooling fan operationHeating fan operation

Set Temp.0.5°C

-0.5°C

2°C

-2°CTime

Quiet and Comfort ControlAir conditioning load factor

Capacity

Operating sound

Time

100%

58 dB

0

0

Heat load

Quiet priority low noise mode

Setting temp.

Normal mode

Time

Tem

pera

ture

Powerful operation mode

(24/30)

33 32 31 30 29 (˚C)

(24/30)

(˚C)15 16 17 18

Horizontal airflow

Vertical airflow

10°C

20°C

“10°C HEAT” Button ON

Indoor unit operation START

Page 8: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

CORE TECHNOLOGY

Indoor unit

Smartphone

Tablet

PCRouter(Field supplied)

Wireless LANInterface(Option)phone

et

Internet

R(

It is the most advanced solution to remotely manage an Air Conditioning system using all sort of mobile devices such as Smartphones, Tablets, and PC.

Fuji Furukawa Engineering & Construction provides an interface that supports central management systems such as KNX®, MODBUS®, BACnet®, and LONWORKS®.

This allows customers to easily perform central control and monitoring of air conditioning equipment.

Easy air conditioner control from inside or outside the house using the Smartphones, Tablets, and PC

N E W

Easy-To-Use ControlResidennttiiaall use

008

Page 9: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

009

CentralRemote Controller

Home central control

SimpleRemote Controller

WiredRemote Controller

Simple individual control

Fuji Furukawa Engineering & Construction is using ergonomics to expand the use of easy-to-use designs such as easy-to-read large LCD panels, easy-to-operate buttons, and displays with easily recognizable icons.

The individual controllers match the user operational environments, and the home controller makes batch energy saving management easy. Ease of use was pursued using simple operation buttons, a large LCD screen, and other features.

Slim WirelessRemote Controller

Fuji Furukawa Engineering & Construction provides various easy-to-use Controllers

Page 10: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

010

20%less

Primary Energy UseFuji Furukawa Engineering & Construction roducts with high efficiency and therefore low electricity input and low primary energy usage

20%less

CO2 EmissionsFuji Furukawa Engineering & Construction products sharply following the F-Gas regulation 842 / 2006 / EC

20%share

of Renewable EnergyFuji Furukawa Engineering & Construction promoting air sourced heat pumps as renewable energy source heating systems

Fuji Furukawa Engineering & Constructionfollowing the EU climate action plan 20/20/20 by 2020

APPROACH TO NEW ENERGY EFFICIENCY STANDARD

Pursuit of Energy Saving Taking Actual Operation into ConsiderationThe heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated value and the annual operating hours per outdoor temperatures was not taken into consideration.

For this reason, SEER and SCOP* have been made the standard in terms of actual operating hours throughout the year.

Fuji Furukawa Engineering & Construction provides air conditioners with higher SEER and SCOP.*SEER and SCOP are indexes that express the annual energy efficiency calculated based on the regulations of (EU) 626/2011.

*: SEER = Seasonal Energy Efficiency Ratio SCOP = Seasonal Coefficient Of Performance

Annual operating hours per outdoor temperature

0403025

Outdoor temperature (°C)2015

Freq

uenc

y (h

)

35

50100150200250

Cooling

Heating

Freq

uenc

y (h

)

0100200300400500600

70-15 15

ColderAverage

Warmer

Page 11: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

011

New Energy Label *

* Enforcement on January 1, 2013 Air conditioners below 12 kW

• Performance notation based on multiple points calculations that better matches the actual operation

• Energy labelling revision• Raising of the CLASS A level

• Three climate zone for heating (Average zone : mandatory) (Warmer and colder zone are

optional)• Seasonal efficiency • Sound power level

Gradual ranking regulation up to A+++ (2013 ~ 2019)

• 2013~: A, B, C, D, E, F, G

• 2015~: A+, A, B, C, D, E, F

• 2017~: A++, A+, A, B, C, D, E

• 2019~: A+++, A++, A+, A, B, C, D

Current Energy Labelling Points New Energy Labelling Points

Operatingpower consumption

Seasonal efficiency

SEER SCOP

• Integrates part load capacity• Optimised for several rating temperatures

Rated efficiency

• Full capacity• One point temperature condition

EER COP

• Operating power consumption• Standby power consumption• Crank case heater• Thermo off

New criteria

Sound pressure level

Annual efficientoperation

Reduce total power consumption

Low noise products

Total power consumption

Sound power level

EER(Cooling mode)

COP(Heating mode)

3.60 < COP

3.60 ≥ COP > 3.40

3.40 ≥ COP > 3.20

3.20 ≥ COP > 2.80

2.80 ≥ COP > 2.60

2.60 ≥ COP > 2.40

2.40 ≥ COP

3.20 < EER

3.20 ≥ EER > 3.00

3.00 ≥ EER > 2.80

2.80 ≥ EER > 2.60

2.60 ≥ EER > 2.40

2.20 ≥ EER

2.40 ≥ EER > 2.20

SEER(Cooling mode)

SCOP(Heating mode)

SEER ≥ 8.50

6.10 ≤ SEER < 8.50

5.60 ≤ SEER < 6.10

5.10 ≤ SEER < 5.60

4.60 ≤ SEER < 5.10

3.60 ≤ SEER < 4.10

3.10 ≤ SEER < 3.60

2.60 ≤ SEER < 3.10

SCOP < 1.90SEER < 2.60

4.10 ≤ SEER < 4.60

SCOP ≥ 5.10

4.60 ≤ SCOP < 5.10

4.00 ≤ SCOP < 4.60

3.40 ≤ SCOP < 4.00

3.10 ≤ SCOP < 3.40

2.50 ≤ SCOP < 2.80

2.20 ≤ SCOP < 2.50

1.90 ≤ SCOP < 2.20

2.80 ≤ SCOP < 3.10

Energy Efficiency ClassificationsNew Energy Labelling Requirement 626 / 2011 / EU : Our models have reached the "Class A" ranking, the highest energy efficiency level that is now shown on energy labels in Europe.

A

RO-RS-

Current Energy Label

Page 12: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

Energy Saving & EcologyDeepening environmental, resources and global warming problems.As a global enterprise, Fuji Furukawa Engineering & Construction recognizesthat contributing to development of a sustainable economic society is today'smost important management topic, and is engaged in a series of environmentalprotection activities reaching up to sales, maintenance, and recycling, and isaggressively making its products more energy saving.

Page 13: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

CONTENTSCore Technology................................................................... 002Approach to New Energy Efficiency Standard ................... 010All Products Lineup ............................................................. 014Feature Explanation ............................................................ 078

SPLIT 016 Wall Mounted ...................................................................... 018Floor .................................................................................... 028Compact Cassette .............................................................. 030Cassette .............................................................................. 032Floor/Ceiling ....................................................................... 034Ceiling ................................................................................. 036Slim Duct ............................................................................ 038Medium Static Pressure Duct ............................................ 040High Static Pressure Duct ................................................. 042

MULTI SPLIT 046 Multi type Line-up ............................................................... 0482 & 3-4 Rooms Multi ........................................................... 0508 Rooms Multi ..................................................................... 052Specifications of All Indoor Units ....................................... 056Multi Combination Table .................................................... 058Simultaneous Multi ............................................................. 068Optional Parts for Split & Multi Split .................................. 070

Page 14: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

ALL TYPE LINEUP SPLIT & MULTI SPLIT

N E W N E W

SPLIT

ROG18LAC2

ROG18LAT3

ROG14LAC2

MULTI SPLIT

Wall MountedPage 18 ~

Up to 2 UnitsPage 50

Up to 3 UnitsPage 50

Up to 4 UnitsPage 50

Simultaneous Multi Twin / TriplePage 68

FloorPage 28

Compact Cassette /CassettePage 30 ~

Floor/CeilingPage 34

CeilingPage 36

Slim DuctPage 38

Medium Static Pressure DuctPage 40

High Static Pressure DuctPage 42 ~

Up to 8 UnitsPage 52

RSG12LMCA RSG14LMCARSG09LMCA

RSG12LLCCRSG09LLCC

N E W

RSG07LLCC

RSG07LMCA RSG18LFCA

RGG09LVCA RGG12LVCA

RCG12LVLB RCG14LVLB RCG18LVLB

RGG14LVCA

RYG18LVTB

RDG18LLTBRDG14LLTBRDG12LLTB

High Spec. & Design

High COP

Standard

Basic

5.318

4.114

3.512

2.69

2.07

Capacity (kW)Model Code

RSG09LTCA RSG12LTCA

RSG12LUCARSG09LUCA RSG14LUCARSG07LUCA

014

Page 15: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

ROG24LAT3

ROG30LAT4

ROG36LATT

[3phase]

ROG45LATT

[3phase]

ROG54LATT

[3phase]

ROG45LBT8

RCG24LVLA

RYG24LVTA

RCG30LRLE

RYG30LRTE

RSG24LFCC RSG30LFCA

25.090

20.072

15.060

14.054

12.545

10.636

8.830

7.124

RDG30LMLERDG24LMLA

RDG45LHTARDG45LHTA [3phase]

RDG54LHTARDG54LHTA [3phase] RDG60LHTA [3phase] RDC72LHTA [3phase] RDC90LHTA [3phase]

RYG54LRTA [3phase]

RDG36LMLERDG36LMLA [3phase]

RDG45LMLARDG45LMLA [3phase]

RYG36LRTERYG36LRTA [3phase]

RYG45LRTARYG45LRTA [3phase]

RCG36LRLERCG36LRLA [3phase]

RCG45LRLARCG45LRLA [3phase]

RCG54LRLARCG54LRLA [3phase]

015

Page 16: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

016

Page 17: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

017

An air conditioner that is people-friendly is also environment-friendly. Fuji Furukawa Engineering & Construction offers a broad lineup of products from large living rooms to bedrooms and children’s rooms. We make your room more comfortable with a wide range of air conditioner types from ceiling wall type with automatic filters and cleaning functions to wall mounted type that improve the air cleaning function. Of course these models feature highly efficient operation that conserves electricity.

Energy saving design to provide a comfortable indoor environment while being environment-friendly.

Wall Mounted

Floor

Compact Cassette

Cassette

Floor/Ceiling

Ceiling

Slim Duct

Medium Static Pressure Duct

High Static Pressure Duct

SPLIT

9 types 54 models

018028030032034036038040042

Page 18: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

018

Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.

Thin & Slim designThin and slim design is realized by high density multi-path heat exchanger and high efficiency wind blower.

Powerful heatingRated heating capacity is maintained up to an outdoor temperature lower than -7 °C. This new model can operate even at -20 °C low outdoor temperature.

Powerful operation mode20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.

Energy saving controlHuman sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode.

Low ambient operation

3 Mode timer (Weekly/Program/Sleep)

Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program timer and sleep timer can be also selected by one push.

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Communication kit:

UTY-RNNXM / UTY-RVNXM

UTY-RSNXM

UTY-TWBXF

Noi

se

Noise level Max. power operating

POWERFULPOWERFULPOWERFUL

10°C HEAT OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied. *Only available with Wireless RC.

Low noisemode

Wall Mounted

Features

Large fan

Open panel

Large intake

40302010

0-10-20 -20°C

Cooling

24°CHeating

43°C

-10°C

3 dBDown

90° 100°

6m 6m

-25 1050-5-10-15-20

1.0

2.0

3.0

4.0 New model

Current model

New model

Current model

-25 1050-5-7-7 -10-15-20

1.0

2.0

3.0

4.02.5-kW class 3.5-kW class

Hea

ting

Cap

acity

(kW

)

Hea

ting

Cap

acity

(kW

)

Outdoor Temperature (°C) Outdoor Temperature (°C)

Wireless R.C. For RSG09LTCA For RSG12LTCA

High Spec. & Design : RSG09LTCA / RSG12LTCA

Page 19: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

019

Dimensions

282

870 185

337

55

100

or m

ore

(Unit : mm)Models: RSG09LTCA / RSG12LTCA

Capacity

EERCOP

Running Current

Energy EfficiencyClass

Moisture Removal

Airflow Rate (High)

Sound Pressure (Cooling)Sound Power (Cooling)

Net Dimension H x W x D

Piping Connections (Small / Large)

Max Height Difference

Operation RangeCoolingHeating

Drain hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)

Annual Energy Consumption

Refrigerant (Global Warming Potential)

HeatingInput Power

Power SourceCooling

Cooling

Indoor / Outdoor

H/M/L/Q High

Heating

Cooling/Heating

Indoor

Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

A

W/W

m3/h

I/h

dB(A)

kWh/a

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

230/1/503.5 (1.1-4.0)4.0 (0.9-6.5)0.850/0.910

4.124.40

4.0/4.3

1.843/37/32/21

48

850/2,050282×870×185

9.5 (21)620×790×290

40 (88)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-20 to 24

R410A (1,975)

230/1/502.5 (0.9-3.5)3.2 (0.9-5.4)0.505/0.660

4.954.85

CoolingHeating (Average) W/W

CoolingHeating

CoolingHeating (Average)

8.504.60A+++A++

8.504.60A+++A++

2.5/3.0 3.5/4.0

2.6/3.3

1.342/36/32/21

48

103912

1441217

800/1,700282×870×185

9.5 (21)540×790×290

33 (73)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-20 to 24

R410A (1,975)

5963

6064

SEERPdesign

SCOP

Cooling/Heating

kWCooling/Heating (@-10°C)

IndoorOutdoor

High High

IndoorOutdoor

RSG12LTCA

ROG12LTC

RSG09LTCA

ROG09LTC

Page 20: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

020

Thin & Slim designThin and slim design is realized by Ø5-mm heat exchanger and high efficiency wind blower.

Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Communication kit:

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTY-TWBXF

Wall Mounted

Features

Big open panel and High density multi path heat exchanger

Ø5 mm

20 mmH282 X W870 X D185 Large fan

Open panel

Distributor 4-path

RefrigerantLarge intake

185 mm

Low ambient operation

3 Mode timer (Weekly/Program/Sleep)

Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program timer and sleep timer can be also selected by one push.

40

30

20

10

0

-10

-20 -15°C

Cooling

24°CHeating

43°C (12/14)46°C (7/9)

-10°C

Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller. N

oise

Noise level Max. power operating

10°C HEAT OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied. *Only available with Wireless RC.

Low noisemode

3 dBDown

Wireless R.C. For RSG07/09LUCA For RSG12/14LUCA

High COP : RSG07LUCA / RSG09LUCA / RSG12LUCA / RSG14LUCA

Page 21: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

021

Dimensions (Unit : mm)

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

Cooling

Cooling

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

230/1/502.5 (0.5-3.2)3.2 (0.5-4.2)0.555/0.680

4.504.71

2.5/2.87.104.10A++A+

3.1/3.41239561.3

42/36/32/21485960

800/1,720282x870x185

9.5 (21)540x660x290

25 (55)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 46-15 to 24

R410A (1,975)

230/1/503.5 (0.9-4.0)4.0 (0.9-5.6)0.905/0.930

3.874.30

3.5/3.97.054.00A++A+

4.6/4.7174

13631.8

43/37/32/21506065

850/1,940282x870x185

9.5 (21)540x790x290

33 (73)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/504.2 (0.9-5.0)5.4 (0.9-6.0)1.235/1.380

3.403.91

4.2/4.86.784.00A++A+

5.8/6.3217

16772.1

45/40/33/25506065

900/1,940282x870x185

9.5 (21)540x790x290

34 (75)6.35/12.7

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/502.0 (0.5-3.0)3.0 (0.5-4.0)0.460/0.660

4.354.55

2.0/2.67.204.10A++A+

2.6/3.497

8871.0

38/35/31/21465758

680/1,720282×870×185

9.5 (21)540×660×290

23 (51)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 46-15 to 24

R410A (1,975)

282

870 185

337

55

100

or m

ore

Models : RSG07LUCA / RSG09LUCA / RSG12LUCA / RSG14LUCA

RSG09LUCA

ROG09LUCB

RSG12LUCA

ROG12LUC

RSG14LUCA

ROG14LUC

RSG07LUCA

ROG07LUCA

Heating (Average)

Heating (Average)

Cooling/Heating (@-10°C)

Page 22: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

022

High efficient compact design More comfort airflow

Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.

24 hr Programmable timer 24 hr program timer and sleep timer can be easily set.

Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.

10°C HEAT OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Communication kit:

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTY-XCBXZ2

Wall Mounted

Features

Making the tube thin:

7 mm 5 mm

Even temperature

Improved heatexchanger effectiveness

High density heat exchanger Power diffuserVertical airflow provides powerful floor level heating.

Horizontal airflow dose not blow cool air directly at occupants in the room.

Heating

Cooling

Low ambient operation

40

30

20

10

0

-10

-20 -15°C

Cooling

24°CHeating

43°C

-10°C

Increase of heat exchangervolume by high density and adopting sub heat exchanger

Wireless R.C. For RSG07/09/12LMCA For RSG14LMCA

Standard : RSG07LMCA / RSG09LMCA / RSG12LMCA / RSG14LMCAN

oise

Noise level Max. power operating

Low noisemode

3 dBDown

Page 23: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

023

Dimensions (Unit : mm)

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

Cooling

Cooling

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

230/1/502.5 (0.5-3.2)3.2 (0.5-4.0)

0.65/0.733.854.38

2.5/2.47.004.10A++A+

3.2/3.51258201.3

43/40/32/21455958

750/1670268X840X203

8.5 (19)535X663X293

21 (46)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/503.4 (0.9-3.9)4.0 (0.9-5.3)

0.97/1.023.503.92

3.4/3.57.004.00A++A+

4.6/4.8170

12251.8

43/40/32/21505961

750/1830268X840X203

8.5 (19)535X663X293

26 (57)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/504.0 (0.9-4.4)5.0 (0.9-6.0)1.135/1.365

3.523.66

4.0/3.96.904.00A++A+

5.3/6.3203

13652.1

44/40/33/25496063

750/1800268X840X203

8.5 (19)540X790X290

34 (75)6.35/12.7

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/502.0 (0.5-3.0)3.0 (0.5-3.4)0.465/0.685

4.304.38

2.0/2.36.804.10A++A+

2.5/3.31037861.0

43/40/32/21455958

750/1670268X840X203

8.5 (19)535X663X293

21 (46)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

840 203

268

Models : RSG07LMCA / RSG09LMCA / RSG12LMCA / RSG14LMCA

RSG09LMCA

ROG09LMCA

RSG12LMCA

ROG12LMCA

RSG14LMCA

ROG14LMCA

RSG07LMCA

ROG07LMCA

Heating (Average)

Heating (Average)

Cooling/Heating (@-10°C)

Page 24: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

024

High efficient compact design

Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.

Economy operationSetting temp. is shifted by 1°C automatically.

ON-OFF Programmable timerYou can set an integrated ON-OFF or OFF-ON timer suitable for your life style. (Setting time: 0.5, 1, 1.5, 2, 2.5, -----9.5, 10, 11, 12 hours)

Super Quiet OperationTop class low noise operation by new airflow construction. Our quiet operation makes the more comfortable environment in a bed room and a study room, etc.

Optional parts

Remote Controller Holder: UTZ-RXLA

Wall Mounted

Features

Volume reduction of heat

exchanger: 30%

Making the tube thin:

7 mm 5 mm

Even temperature

Improved heatexchanger effectiveness

High density heat exchanger

OFF-ON timer

From sleep to wake up

ON-OFF timer

From wake up to go to work

OFF10hours

ON 7hours

12

6

9 3

PM11:00 set

12

6 ON

9hours

OFF2hours

9PM9:00 set

3

QuietFan speed

22 dB (A)Noise level

Low ambient operation

40

30

20

10

0

-10

-20 -15°C

Cooling

24°CHeating

43°C

-10°C

Tem

p.

Economy operation

Shift setting temp

Normal operation

Time

Set temperature

(In case of cooling operation)

Wireless R.C.

Basic : RSG07LLCC / RSG09LLCC / RSG12LLCC

Page 25: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

025

Dimensions (Unit : mm)

820 206

262

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

CoolingHeating (Average)

Heating (Average)

Cooling/Heating (@-10°C)

Cooling

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

230/1/503.4 (0.9-3.8)4.0 (0.9-5.0)1.080/1.130

3.153.54

3.4/3.26.603.80A++

A5.2/5.4

1801,179

1.843/38/33/22

505965

720/1,830262×820×206

7.0 (15)535×663×293

26 (57)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/502.0 (0.9-2.8)2.7 (0.9-3.6)0.470/0.620

4.264.35

2.0/2.26.704.00A++A+

2.6/3.01047701.0

43/38/33/22475961

720/1,670262×820×206

7.0 (15)535×663×293

24 (53)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/502.5 (0.9-3.0)3.0 (0.9-3.8)0.730/0.740

3.424.05

2.5/2.36.904.00A++A+

3.5/3.51278051.3

43/38/33/22475961

720/1,670262×820×206

7.0 (15)535×663×293

24 (53)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

Models : RSG07LLCC / RSG09LLCC / RSG12LLCC

RSG12LLCC

ROG12LLCC

RSG07LLCC

ROG07LLCC

RSG09LLCC

ROG09LLCC

Page 26: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

026

Ion Deodorization Filter

Apple-catechin Filter

Air Filter

Organic coating fin used heat exchanger

Antibacterial deodorizing pre-filter with special ceramic powder

“Vertical airflow” provides powerful floor level heating

Easy maintenanceSimplification of drain pan cleaning improves maintenance-ability.

Flexible InstallationAir conditioner filter features

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Wall Mounted

Features

(18/30)(24)

Power diffuser

Power diffuser (full open)46o

(˚C)

15 16 17 18

Outside air conditions: 35˚C 40% Operation contents: Cooling, Set temperature (Min set temp) 18˚C, airflow Hi, Air direction upward and front

(24/30)

Outside air conditions: 2˚C 60% Operation contents: Heating, Set temperature (Max set temp) 30˚C, airflow Hi, Air direction downward and front

33 32 31 30 29

(˚C)

(24/30)

“Horizontal airflow” does not blow cool air directly at the occupants inthe room

Ion Deodorization Filter

Apple-catechin Filter

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.

Using different filters at both sides

20 m

25 m18 type

30 m

50 m30 type

20 m

30 m24 type

Max. Height

Max. Piping Length

Low ambient operation5040302010

0-10

-15°C

Cooling

24°CHeating

46°C

-10°C

Standard : RSG18LFCA / RSG24LFCC / RSG30LFCA

For RSG18LFCA RSG24LFCC

For RSG30LFCAWireless R.C.

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

Page 27: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

027

Dimensions (Unit : mm)

998

238

320

520

520

590721

25

ø32

ø16

ø12

Refrigerant pipe flare connection (Liquid)

Refrigerant pipe flare connection (Gas)

Drain hose connection (Drain hose)2

1

3

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

Cooling

Cooling

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

230/1/507.1 (0.9-8.0)

8.0 (0.9-10.6)2.20/2.21

3.233.61

7.1/7.16.113.80A++

A9.7/9.7

40626102.7

49/42/37/32556468

1120/2460320X998X238

14 (31)620X790X298

41 (90)6.35/15.88

12/1630 (15)

20-10 to 46-15 to 24

R410A (1,975)

230/1/508.0 (2.9-9.0)8.8 (2.2-11.0)

2.49/2.443.213.61

8.0/8.05.693.80A+A

10.9/10.7492

29413.2

48/42/37/33536468

1100/3600320X998X238

14 (31)830X900X330

61 (135)9.52/15.88

12/1650 (20)

30-10 to 46-15 to 24

R410A (1,975)

230/1/505.2 (0.9-6.0)6.3 (0.9-9.1)

1.52/1.713.423.68

5.2/5.96.943.87A++

A6.8/7.6

26221302.6

43/37/33/26505865

900/2150320X998X238

14 (31)620X790X298

41 (90)6.35/12.8

12/1625 (15)

20-10 to 46-15 to 24

R410A (1,975)

RSG24LFCC

ROG24LFCC

RSG30LFCA

ROG30LFT

RSG18LFCA

ROG18LFC

Models : RSG18LFCA / RSG24LFCC / RSG30LFCA

Heating (Average)

Heating (Average)

Cooling/Heating (@-10°C)

Page 28: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

028

Flexible & easy installation

Filter features

10°C HEAT OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied

Easy maintenanceRemovable and washable panel

2-Fan & Wide airflow

Flexible pipingconnection 6 direction ofdrain & piping

Low ambient operation

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Half Concealed Kit:

Floor

Features

Cooling

at operationstart

at operationstart

Heating WindowPrevents cold draft from window

at stableoperation

Prevents cold air from falling

at stableoperation

Beneathstandard window

Standard concaveportion Wall Half concealed

(Optional parts necessary)

(unit:mm)

600

740200

700

(unit:mm)

Min.700

Min. 590

Min.940

(unit:mm) (unit:mm)Max. 150

Min. 730 Max. 80

Ion Deodorization Filter

Apple-catechin Filter

Using different filters at both sides

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

The Apple-catechin filter uses static electricity to clean fine particles and dust in the air.

Apple-catechin Filter

Ion Deodorization Filter

Back view

Drain hose Piping

1 62 53 4

Removable panel

5040302010

0-10

43°C

-15°C

Cooling

24°CHeating

-10°C

Wireless R.C.

Model : RGG09LVCA / RGG12LVCA / RGG14LVCA

For RGG09/12LVCA For RGG14LVCA

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTR-STA

Page 29: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

029

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

Cooling

Cooling

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

Dimensions (Unit : mm)

230/1/504.2 (0.9-5.0)5.2 (0.9-8.0)

1.14/1.443.683.61

4.2/4.76.404.00A++A+

5.2/6.4230

16452.1

44/38/31/22505865

650/1910600x740x200

14 (31)578x790x300

40 (88)6.35/12.7

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/503.5 (0.9-4.0)4.5 (0.9-6.6)

0.94/1.193.723.78

3.5/3.86.504.00A++A+

4.4/5.5188

13301.8

40/35/29/22485564

570/1680600x740x200

14 (31)540x790x290

36 (79)6.35/9.52

13.8/15.8 to16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

230/1/502.6 (0.-3.5)

3.5 (0.9-5.5)0.53/0.79

4.914.43

2.6/2.97.004.20A++A+

2.6/3.81309671.3

40/35/29/22475564

570/1680600x740x200

14 (31)540x790x290

36 (79)6.35/9.52

13.8/15.8 to 16.720 (15)

15-10 to 43-15 to 24

R410A (1,975)

200

600

740Front view Side view

Models : RGG09LVCA / RGG12LVCA / RGG14LVCA

RGG14LVCA

ROG14LVLA

RGG12LVCA

ROG12LVCA

RGG09LVCA

ROG09LVCA

Heating (Average)

Heating (Average)

Cooling/Heating (@-10°C)

Page 30: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

030

2-stage turbo fanHigh efficiency design by 2 stage structure

Easy maintenance

High lift drain pump

Quiet qualityOptimization of wing form (laminar wing type) and wing number (7 blades each)

Compact designWorlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size)

Optional parts

Air Outlet Shutter Plate:

Wired Remote Controller:

Simple Remote Controller:

Insulation Kit For High Humidity:

Fresh Air Intake Kit:

Compact Cassette

Features

ABCD

Grille cover2

1

3

: standard equipment

During installation, maintenance and operation, the drain pump and kit can be checked easily.

Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. A : Fan motorC : Bell-mouth

B : 2-stage turbo fanD : Panel

1 Maintenance of fan motor and fan

2 Air filter

3 Adaptation of transparent drainage parts

700 mm

Adoption of laminar wing

Spin direction Airflow direction

Quiet

Airflow runs through smoothly along the laminar wing

No airflow separation

Laminar wingQuiet

Previous turbo fan 2-stage turbo fan

1-stage

+2-stage2 stage

Fast

Slow

Windvelocity In the case of a conventional

fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.

Designed by CFD-analysis (fluid) simulations

Heat exchangeefficiency:

20%UP

A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.

Low ambient operation5040302010

0-10

46°C

-15°C

Cooling

24°CHeating

-10°C

Wireless R.C. For RCG12/14/18LVLB

Model : RCG12LVLB / RCG14LVLB / RCG18LVLB / RCG24LVLA

For RCG24LVLA

UTR-YDZB

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTZ-KXGC

UTZ-VXAA

Page 31: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

031

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)Cassette Grille

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

CoolingHeating (Average)

Heating (Average)

Cooling/Heating (@-10°C)

Cooling

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

Dimensions (Unit : mm)

230/1/506.8 (0.9-8.0)8.0 (0.9-9.1)

2.21/2.263.083.54

6.8/6.05.603.90A+A

9.7/9.9425

21512.7

49/44/36/30525967

930/2470245×570×570/49x700x700

16 (35) / 2.6 (6)578x790x315

44 (97)6.35/15.88

25/3230 (15)

20-10 to 46-15 to 24

R410A (1,975)CG-UFFD

230/1/505.2 (0.9-5.9)6.0 (0.9-7.5)

1.62/1.663.213.61

5.2/5.26.204.20A++A+

7.2/7.4293

17312.2

38/34/30/26505062

680/2000245×570×570/49x700x700

15 (33) / 2.6 (6)578x790x300

40 (88)6.35/12.70

25/3225 (15)

15-10 to 46-15 to 24

R410A (1,975)CG-UFFD

230/1/504.3 (0.9-5.4)5.0 (0.9-6.5)

1.33/1.343.213.71

4.3/4.56.404.40A++A+

6.1/6.1235

14321.5

38/34/30/27495062

680/1910245×570×570/49x700x700

15 (33) / 2.6 (6)578×790×300

40 (88)6.35/12.70

25/3225 (15)

15-10 to 46-15 to 24

R410A (1,975)CG-UFFD

230/1/503.5 (0.9-4.4)4.1 (0.9-5.7)

1.05/1.113.333.69

3.5/4.26.204.10A++A+

4.8/5.1198

14311.2

37/34/30/27474961

600/1780245×570×570/49x700x700

15 (33) / 2.6 (6)578×790×300

40 (88)6.35/9.52

25/3225 (15)

15-10 to 46-15 to 24

R410A (1,975)CG-UFFD

285 285

Ceiling

114

114

700

700

IR receiver

□ 57

0 : I

ndoo

r uni

t

370 54

0Ha

nging

bolt

pos

ition

□ 58

0 to

660

Cei

ling

open

ings

530

530Hanging bolt position

Drain hose

215

19

30 123

30 262

183

Control Box

14640

Liquid pipeGas pipe

RCG24LVLA

ROG24LALA

RCG18LVLB

ROG18LALL

RCG14LVLB

ROG14LALL

RCG12LVLB

ROG12LALL

Models : RCG12LVLB / RCG14LVLB / RCG18LVLB / RCG24LVLA

Page 32: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

032

Optional parts

Wired Remote Controller:

Simple Remote Controller:

IR Receiver Kit:

Wide Panel:

Panel Spacer:

Air Outlet Shutter Plate:

Insulation Kit For High Humidity:

Fresh Air Intake Kit:

Cassette

Features

Singlephase

450 mm 500 mm

WindvelocityHeat exchanger

< Motor side >

Uneven airflow

Fast

SlowConventional blade

Separation phenomenon of airflow causes noise

: Spin direction : Airflow direction : Turbulent flow noise

< Motor side >Heat exchanger

3-dimensional blade

No airflow separation

Previous turbo fan: Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.

New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.

Quiet

High efficiency turbo fan with 3-dimensional blade

Much less temperature irregularity by spreading airflow widely

Bottom view

Front part Ceiling

Rear part

Round louvre

Improvement of the airflow distribution New louvre: The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide airflow distribution.

Ceiling panel

850 mm

High lift drain pump

Detachable Grille corner

Adjustment can be done just taking off the corner part

Adjustment of hanger position is possible after installation

Low ambient operation5040302010

0-10

46°C

-15°C

Cooling

24°CHeating

-15°C

Model : RCG30LRLE / RCG36LRLE / RCG45LRLA / RCG54LRLA / RCG36LRLA [3phase] / RCG45LRLA [3phase] / RCG54LRLA [3phase]

For RCG30/36LRLEWired R.C. For RCG36/45/54LRLA

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTY-LRHXA2

UTG-AGYA-W

UTG-BGYA-W

UTR-YDZC

UTZ-KXGA

UTZ-VXGA

Page 33: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

033

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)Cassette Grille

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

CoolingCooling/Heating

HeatingCoolingHeating

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

Dimensions (Unit : mm)

400/3/5014.0 (5.4-16.0)16.0 (5.8-18.0)

4.36/4.433.213.61

-----

6.5/6.6--

5.047/43/41/37

55--

2000/6900288x840x840 50x950x95026 (57) / 5.5 (12)1290×900×330

104 (229)9.52/15.8825.0/32.075 (30)

30-15 to 46-15 to 24

R410A (1,975)CG-GFA

400/3/5012.5 (5.0-14.0)14.0 (5.4-16.2)

3.54/3.583.533.91

-----

5.3/5.3--

4.546/42/40/36

54--

1900/6900288x840x840 50x950x95026 (57) / 5.5 (12)1290×900×330

104 (229)9.52/15.8825.0/32.075 (30)

30-15 to 46-15 to 24

R410A (1,975)CG-GFA

400/3/5010.0 (4.7-11.4)11.2 (5.0-14.0)

2.44/2.564.104.38

10.0/10.06.504.30A++A+

3.7/3.9573

32533.0

44/39/36/33515867

1800/6200288x840x840 50x950x95026 (57) / 5.5 (12)1290×900×330

104 (229)9.52/15.8825.0/32.075 (30)

30-15 to 46-15 to 24

R410A (1,975)CG-GFA

230/1/5013.3 (4.5-14.5)16.0 (4.7-16.5)

4.42/4.693.013.41

-----

19.3/20.5--

5.047/43/41/37

55--

2000/6750288x840x840 50x950x95026 (57) / 5.5 (12)1290×900×330

86 (190)9.52/15.8825.0/32.050 (20)

30-15 to 46-15 to 24

R410A (1,975)CG-GFA

230/1/5012.5 (4.0-14.0)14.0 (4.2-16.2)

3.88/3.773.223.71

-----

17.0/16.5--

4.546/42/40/36

55--

1900/6750288x840x840 50x950x95026 (57) / 5.5 (12)1290×900×330

86 (190)9.52/15.8825.0/32.050 (20)

30-15 to 46-15 to 24

R410A (1,975)CG-GFA

230/1/5010.0 (2.8-11.2)11.2 (2.7-12.7)

3.12/3.023.213.71

10.0/8.76.304.20A++A+

13.7/13.355528973.5

43/38/36/32545769

1800/3800288x840x840 50x950x95026 (57) / 5.5 (12)

830x900x33061 (135)

9.52/15.8825.0/32.050 (20)

30-15 to 46-15 to 24

R410A (1,975)CG-GFA

230/1/508.5 (2.8-10.0)10.0 (2.7-11.2)

2.65/2.773.213.61

8.5/8.06.504.30A++A+

11.6/12.245826042.5

40/38/36/32535468

1600/3600288x840x840 50x950x95026 (57) / 5.5 (12)

830x900x33061 (135)

9.52/15.8825.0/32.050 (20)

30-15 to 46-15 to 24

R410A (1,975)CG-GFA

796Hanging bolt position

Drain hose358

□ 84

0 : I

ndoo

r uni

t60

7 420

699

Hang

ing

bolt

posit

ion

□ 86

0 to

910

Cei

ling

open

ing

142

142

Ceiling

950IR receiver(Option)

950

(Control) Box

200

10

358 278 60

44

40

Wire holeGas pipeLiquid pipe 14

029

8(25

6)

RCG54LRLA

ROG54LATT

RCG45LRLA

ROG45LATT

RCG36LRLA

ROG36LATT

RCG54LRLA

ROG54LETL

RCG45LRLA

ROG45LETL

RCG36LRLE

ROG36LETL

RCG30LRLE

ROG30LETL

Models : RCG30LRLE / RCG36LRLE / RCG36LRLA / RCG45LRLA / RCG54LRLA

Page 34: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

034

Double auto swingA combination of right/left and up/down directional swing allows 3-dimensional air direction control

Easy installationMain work settings can be done easily from the remote controller at installation

Low ambient operation

Flexible installation

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Floor/Ceiling

Features

Floor console Under ceilingExample for floor installation Example for ceiling installation

Right and Left Swing

12

54

3

5 steps selectableStepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode

Up and Down Swing1

2

54

3

7 steps selectable

67

Main work settingsHigh ceiling settingAuto restart Temperature adjustment when cooling / heating

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

-10°C

46°C

Wireless R.C.

Model : RYG18LVTB / RYG24LVTA

For RYG18LVTB For RYG24LVTA

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

Page 35: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

035

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

CoolingCooling/Heating

HeatingCoolingHeating

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

Dimensions (Unit : mm)

230/1/506.8 (0.9-8.0)8.0 (0.9-9.1)

2.21/2.263.083.54

6.8/6.05.603.90A+A

9.7/9.9425

21502.7

48/44/40/35526167

980/2470199x990x655

27 (59)578x790x315

44 (97)6.35/15.88

25/3230 (15)

20-10 to 46-15 to 24

R410A (1,975)

230/1/505.2 (0.9-5.9)6.0 (0.9-7.5)

1.62/1.663.213.61

5.2/5.26.104.00A++A+

7.2/7.4298

18192.0

43/40/34/31505762

780/2000199x990x655

27 (59)578x790x300

40 (88)6.35/12.70

25/3225 (15)

15-10 to 46-15 to 24

R410A (1,975)

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3

22

3 3

1

1

990

100 19

0

200

175

124

530 65

5

43

145

100

13634227

162

100 80 98

47 100100

124 742

5658467267

100

199

20

28

900500

Models : RYG18LVTB / RYG24LVTA

RYG24LVTA

ROG24LALA

RYG18LVTB

ROG18LALL

Page 36: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

036

Easy installationMain work settings can be done easily from the remote controller at installation

Fresh air intake

Condensate lift-up mechanism (Option)Optional drain lift-up mechanism allows flexible installation.

Multi auto swingA combination of right/left and up/down directional swing allows 3-dimensional air direction control.

Installation

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Drain Pump Unit:

Flange:

Ceiling

Features

Singlephase

StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode

Right and Left Swing Up and Down Swing

5 steps selectable 5 steps selectable

1

2

5

4

3

12

54

3

(Field Supplied)

Open Concealed

Wall mounted

Max.

500 mm

Low ambient operation5040302010

0-10

46°C

-15°C

Cooling

24°CHeating

-15°C

OutdoorIndoor

Freshair

Setting by wireless or wired remote controller

Conventional type

1 2 3

O F F

SW1 (Optional parts)

Setting by DIP switch inside control box

Main work settings•High ceiling setting•Auto restart •Temperature adjustment when cooling / heating

Wireless R.C.

Model : RYG30LRTE / RYG36LRTE / RYG45LRTA / RYG36LRTA [3phase] / RYG45LRTA [3phase] / RYG54LRTA [3phase]

For RYG30/36LRTE For RYG36/45/54LRTA

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTR-DPB24T

UTD-RF204

Page 37: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

037

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

CoolingCooling/Heating

HeatingCoolingHeating

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/h

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

Dimensions (Unit : mm)

400/3/5012.5 (5.0-14.0)14.0 (5.4-16.2)

3.89/3.883.213.61

-----

5.8/5.8--

4.549/45/39/34

54--

2100/6900240x1660x700

46 (101)1290×900×330

104 (229)9.52/15.8821.5/26.075 (30)

30-15 to 46-15 to 24

R410A (1,975)

400/3/5014.0 (5.4-16.0)16.0 (5.8-18.0)

4.65/4.673.013.43

-----

6.9/6.9--

5.051/48/42/38

55--

2300/6900240x1660x700

48 (106)1290×900×330

104 (229)9.52/15.8821.5/26.075 (30)

30-15 to 46-15 to 24

R410A (1,975)

400/3/5010.0 (4.7-11.4)11.2 (5.0-14.0)

2.84/2.873.523.90

10.0/10.06.104.10A++A+

4.3/4.4573

34143.0

47/43/37/32516167

1900/6200240x1660x700

46 (101)1290×900×330

104 (229)9.52/15.8821.5/26.075 (30)

30-15 to 46-15 to 24

R410A (1,975)

230/1/509.4 (2.8-11.2)

11.2 (2.7-12.7)2.93/3.02

3.213.71

9.4/8.76.004.10A+A+

12.8/13.2548

29653.0

47/43/37/32546069

1900/3800240×1660×700

46 (101)830x900x330

61 (134)9.52/15.8821.5/26.050 (20)

30-15 to 46-15 to 24

R410A (1,975)

230/1/508.5 (2.8-10.0)10.0 (2.7-11.2)

2.65/2.773.213.61

8.5/8.06.104.20A++A+

11.6/12.2487

26622.5

45/43/37/32535768

1660/3600240×1660×700

46 (101)830x900x330

61 (134)9.52/15.8821.5/26.050 (20)

30-15 to 46-15 to 24

R410A (1,975)

230/1/5012.1 (4.0-13.3)13.3 (4.2-15.5)

3.77/3.683.213.61

-----

16.5/16.1--

4.049/45/39/34

55--

2100/6200240×1660×700

46 (101)1290×900×330

86 (189)9.52/15.8821.5/26.050 (20)

30-15 to 46-15 to 24

R410A (1,975)

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3

2 1 33

16601600

700

300

130

160

192

1658833

200

150

3024082

137

160

150

65

135

202

160118

115100

160

95

RYG45LRTA

ROG45LATT

RYG54LRTA

ROG54LATT

RYG36LRTA

ROG36LATT

RYG36LRTE

ROG36LETL

RYG30LRTE

ROG30LETL

RYG45LRTA

ROG45LETL

Models : RYG30LRTE / RYG36LRTE / RYG36LRTA / RYG45LRTA / RYG54LRTA

Page 38: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

038

Air-intakeAir intake direction can be selected to match the installation site.

Selectable with a wide range of static pressure

Auto Louver Grille Kit (Option)

Drain hose as standard accessoryFor flexible installation.

Slim designThe slim design allows installations where ceilings are narrow.

Flexible installation

Optional parts

Wired Remote Controller:

Simple Remote Controller:

IR Receiver Kit:

Remote Sensor Unit:

Auto Louver Grille Kit:

Slim Duct

Features

Drain port

Drain pumpbuilt-in

Height198 mm

Drain pump

Floor concealedCeiling concealed

Drain hose is standard accessory

Max.850 mm

Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.

By using the DC fan motor, it is possible to change the static pressure rangefrom 0 to 90 Pa. The change of static pressure range is possible by remote controller.

Static pressure range0 to 90 Pa

Wired RemoteController

Wireless RemoteController

4 steps selectable and auto swing

Auto Louver Grille Duct type

Back sideBottom side

Model : RDG12LLTB / RDG14LLTB / RDG18LLTB

Wired R.C.RDG12/14LLTB RDG118LLTB

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTY-LRHXM

UTY-XSZX

UTD-GXSA-W (For RDG12 / 14LLTB)

UTD-GXSB-W (For RDG18LLTB)

Page 39: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

039

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High) Static pressure range (Standard)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

CoolingCooling/Heating

HeatingCoolingHeating

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/hPa

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

Dimensions (Unit : mm)

230/1/504.3 (0.9-5.4)5.0 (0.9-6.5)

1.33/1.343.213.71

4.3/4.55.803.90A+A

6.1/6.1259

16141.5

32/30/28/26496062

800/19100 to 90 (25)

198x700x62019 (42)

578x790x30040 (88)

6.35/12.7025/32

25 (15)15

-10 to 46-15 to 24

R410A (1,975)

230/1/503.5 (0.9-4.4)4.1 (0.9-5.7)

1.05/1.113.333.69

3.5/4.25.904.00A+A+

4.8/5.1207

14671.3

29/28/26/25475861

650/17800 to 90 (25)

198x700x62019 (42)

578x790x30040 (88)

6.35/9.5225/32

25 (15)15

-10 to 46-15 to 24

R410A (1,975)

230/1/505.2 (0.9-5.9)6.0 (0.9-7.5)

1.62/1.663.213.61

5.2/5.26.204.10A++A+

7.2/7.4293

17742.0

32/30/29/27505862

940/20000 to 90 (25)

198x900x62023 (51)

578x790x30040 (88)

6.35/12.7025/32

25 (15)15

-10 to 46-15 to 24

R410A (1,975)

700ABCD

EF

G

650734650

P100x6=60018xØ5

574

900850934850

P100x8=80022xØ5

774

(Bol

t pitc

h)

G51

152

377

174

713030

F(All surroundings)

82

48

EDC

(Bolt pitch) 43

31

198

168

78

BA

10

69144264367

47557889119

163

RDG14LLTB

ROG14LALL

RDG12LLTB

ROG12LALL

RDG18LLTB

ROG18LALL

Models : RDG12LLTB / RDG14LLTB / RDG18LLTB

RDG12 / 14LLTB RDG18LLTB

Page 40: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

040

Slim & Compact designIn the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270 mm, Further space savings have been achieved by mounting the control box internally inside the chassis.

Easy installationMain work settings can be done easily from the remote controller at installation

Easy maintenanceStructural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.

Two-direction drain piping

Low ambient operation

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Flange (Round):

Flange (Square):

Long Life Filter:

Remote Sensor Unit:

Drain Pump Unit:

IR Receiver Kit:

Medium Static Pressure Duct

Features

(24)

Singlephase

(30/36/45)

1,135 mm1,200 mm

270 mm

Control box is now included as part of the main chassis

One touch operation and easy to install long life filter (Optional Parts)

See below for the case of rear suction type

Setting by wired remote controller Conventional type

1 2 3

O F F

SW1

Setting by DIP switch inside control box

Main work settings•High ceiling setting•Auto restart •Temperature adjustment when cooling / heating

1.Control box2.Fan casing3.Fan4.Motor

Previous model

2

4

13

Large bottom panel: 1 piece

New model 1

4

32

Bottom panel: 2 pieces

Two-direction drain pipingDuct indoor unit

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

46°C

-15°C-10°C (24 type only)

Model : RDG24LMLA / RDG30LMLE / RDG36LMLE / RDG45LMLA / RDG36LMLA [3phase] / RDG45LMLA [3phase]

For RDG36/45LMLAFor RDG24LMLA For RDG30/36LMLEWired R.C.

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTD-RF204

UTD-SF045T

UTD-LF25NA

UTY-XSZX

UTZ-PX1NBA

UTY-LRHXM

Page 41: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

041

Capacity

EERCOP

SEERPdesign

SCOP

Running CurrentAnnual Energy Consumption

Energy Efficiency Class

Moisture Removal Sound Pressure(Cooling) Sound Power (Cooling) Airflow Rate (High) Static pressure range (Standard)

Net Dimension H x W x D

Drain Hose Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Max Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant (Global Warming Potential)

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

HighHighHigh

IndoorOutdoor

Heating

CoolingCooling/Heating

HeatingCoolingHeating

CoolingHeating

Cooling/Heating

Indoor / Outdoor

°CDB

mm

m

kg(lbs)mm

kW

kg(lbs)

W/W

W/W

kW

m3/hPa

I/h

A

kWh/a

dB(A)

mm

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

Dimensions (Unit : mm)

230/1/5012.1 (4.0-13.3)13.3 (4.2-15.5)

3.77/3.683.213.61

-----

16.5/16.1--

4.042/38/32/28

55--

2100/620030 to 150 (60)270x1135x700

40 (88)1290×900×330

86 (189)9.52/15.8835.7/38.150 (20)

30-15 to 46-15 to 24

R410A (1,975)

400/3/5010.0 (4.7-11.4)11.2 (5.0-14.0)

2.84/2.873.523.90

10.0/10.05.804.00A+A+

4.3/4.4603

34973.0

38/36/31/26516567

1800/620030 to 150 (47)270x1135x700

40 (88)1290x900x330

104 (229)9.52/15.8835.7/38.175 (30)

30-15 to 46-15 to 24

R410A (1,975)

230/1/506.8 (0.9-8.0)8.0 (0.9-9.1)

2.21/2.263.083.54

6.8/6.06.204.00A++A+

9.7/9.9384

20982.5

31/29/27/25526067

1100/247030 to 150 (35)270x1135x700

38 (84)578x790x315

44 (97)6.35/15.8835.7/38.130 (15)

20-10 to 46-15 to 24

R410A (1,975)

230/1/508.5 (2.8-10.0)10.0 (2.7-11.2)

2.65/2.683.213.73

8.5/8.05.903.90A+A

11.6/11.7504

28682.5

39/35/30/26536568

1900/360030 to 150 (47)270x1135x700

40 (88)830x900x330

61 (134)9.52/15.8835.7/38.150 (20)

30-15 to 46-15 to 24

R410A (1,975)

230/1/509.4 (2.8-11.2)

11.2 (2.7-12.7)2.96/3.10

3.183.61

9.4/8.75.703.80A+A

13.0/13.6576

32023.0

39/35/30/26546569

1900/380030 to 150 (47)270x1135x700

40 (88)830x900x330

61 (134)9.52/15.8835.7/38.150 (20)

30-15 to 46-15 to 24

R410A (1,975)

400/3/5012.5 (5.0-14.0)14.0 (5.4-16.2)

3.89/3.883.213.61

-----

5.8/5.8--

4.542/38/32/28

54--

2100/675030 to 150 (60)270x1135x700

40 (88)1290×900×330

104 (229)9.52/15.8835.7/38.175 (30)

30-15 to 46-15 to 24

R410A (1,975)

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection

21

3Rear view

Top view

Side view (R)Side view (L)

Front view240270

10710151135

173161 44

7(Bo

lt pi

tch)

1177(Bolt pitch)Outlet

27032

ø200(knock

out hole)

240

121P.C.D. ø225

1146632

1

3

3

2

168

281

240

700

138

138

264 264 264

ø205 hole

82

75

Models : RDG24LMLA / RDG30LMLE / RDG36LMLE / RDG36LMLA / RDG45LMLA

RDG45LMLA

ROG45LETL

RDG36LMLA

ROG36LATT

RDG24LMLA

ROG24LALA

RDG30LMLE

ROG30LETL

RDG36LMLE

ROG36LETL

RDG45LMLA

ROG45LATT

Page 42: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

042

Low noise

High energy efficiencySignificantly greater efficiency is realized by using all DC inverter technology. (60 type)

Low ambient operation

Easy installation (Compact size & Lightweight)A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Long-Life Filter:

Remote Sensor Unit:

IR Receiver Kit:

High Static Pressure Duct

Features

Singlephase

45/54 type

45/54 type

60 type

45/54 type 60 type

1,050 500

400

(unit: mm)

Design also corresponding to high static pressure

MAX.

250 pa

MAX.

260 pa

50

40

30

20

10

0

-10

-15°C

Cooling

24°CHeating

46°C

-15°C

Heat exchanger

Plastic fan

Casing (Plastic)

ø225 mm

Cutting off the corners has enabled less turbulent airflow.Low noise is realized by adopting a plastic case and a plastic fan.

Indoor unit

2 stage low noise mode can be selected. (Option)Outdoor unit

Roted noise value

Mode 1

Mode 2

Lownoisemode

-4 dB-2 dB

Med. noise level

43 dB(A)

1,250 490

425

Model : RDG45LHTA / RDG54LHTA / RDG45LHTA [3phase] / RDG54LHTA [3phase] / RDG60LHTA [3phase]

Wired R.C.RDG45/54LHTA RDG60LHTA

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTD-LF60KA (For RDG45/54LHTA only)

UTY-XSZX

UTY-LRHYM(For RDG60LHTA only)

Page 43: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

043

Dimensions (Unit : mm)

Capacity

EER COP Running Current Moisture Removal

Airflow Rate (High) Static pressure range (Standard)

Sound Pressure (Cooling)

Net Dimension H x W x D

Max Pipe Length (Pre-Charge)Height Difference

CoolingHeating

Piping Connections (Small / Large) Drain Hose Diameter (I.D./O.D.)

Operation Range

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/LOutdoor

Indoor

Outdoor

High

Heating Cooling/Heating

Indoor / Outdoor

kW

W/W

A I/h

dB(A)

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

230/1/5012.5 (4.5-14.0)14.0 (5.0-16.2)

4.30/3.802.913.68

18.9/16.71.5

47/43/4055

3350/6750100 to 250 (100)400x1050x500

46 (101)1290x900x330

86 (189)9.52/15.8823.4/25.450 (20)

30-15 to 46-15 to 24R410A

230/1/5013.4 (5.0-14.5)16.0 (5.5-18.0)

4.77/4.692.813.41

20.9/20.52.0

47/43/4055

3350/6750100 to 250 (100)400x1050x500

46 (101)1290x900x330

86 (189)9.52/15.8823.4/25.450 (20)

30-15 to 46-15 to 24R410A

400/3/5012.5 (5.0-14.0)14.0 (5.4-16.2)

4.06/3.673.083.81

6.1/5.51.5

47/43/4054

3350/6750100 to 250 (100)400x1050x500

46 (101)1290x900x330

104 (229)9.52/15.8823.4/25.475 (30)

30-15 to 46-15 to 24R410A

400/3/5015.0 (6.2-17.5)18.0 (6.2-20.0)

4.70/5.153.193.50

6.9 /7.62.0

45/40/3656

3550/690060 to 260 (60)425x1250x490

54 (119)1290x900x330

104 (229)9.52/15.8823.4/25.475 (30)

30-15 to 46-15 to 24R410A

400/3/5014.0 (5.4-16.0)16.0 (5.8-18.0)

4.65/4.373.013.66

6.9/6.52.5

47/43/4055

3350/6900100 to 250 (100)400x1050x500

46 (101)1290x900x330

104 (229)9.52/15.8823.4/25.475 (30)

30-15 to 46-15 to 24R410A

°CDB

m

mmmm

kg(lbs)

m3/hPamm

kg(lbs)mm

Front view

Top viewSide view (L)

Side view (R)

Rear view

88

400 1,0801,000 (Bolt pitch)

862

8511,050 85

371356

208

41 123

139108

1

2

3

4

324 14

295

585

500(

Bol

t pitc

h)

71

Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)

Drain piping connection (Safety drain pan)21 3

Drain piping connection(Main drain pan)4

Top view

Rear view

Front view

Side view (L)Side view (R)

1

2

425351 14

30304 921 152

87

1062 10639

400382

272

28 119

146

172

490

1260

1232

1250

4457

2

3052

6 (B

olt p

itch)

1192 (Bolt pitch)

39

181

Models : RDG45LHTA / RDG54LHTA / RDG60LHTA

RDG45LHTA

ROG45LETL

RDG54LHTA

ROG54LETL

RDG45LHTA

ROG45LATT

RDG60LHTA

ROG60LATT

RDG54LHTA

ROG54LATT

Model: RDG45LHTA / RDG54LHTA Model: RDG60LHTA

Page 44: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

044

Pursuance of amenity performanceVarious remote controllers and sensors can be selected.

Optional parts

Wired Remote Controller:

Simple Remote Controller:

Remote Sensor Unit:

High Static Pressure Duct

Features

Outdoor unit Indoor unit

Front panel

Fan motor

Outdoor unit quiet operationA low outdoor noise operation mode allows the outdoor unit to have two quiet mode operation settings.

High energy efficiencySignificantly greater efficiency is realized by using DC twin rotary compressor, all DC inverter technology, and large heat exchanger.

Peak cut operationA peak power consumption mode controls a 4 step outdoor operation control to cut down energy usage at peak energy usage times.

Easy Service & Maintenance• Split front panel allows for maintenance from top or bottom of the

outdoor unit• Fan motors of the indoor unit can be removed separatly5 Static Pressure selection

Improvement and design flexibility has allowed multiple fan speeds and static pressure modes. Low noise is realized by adopting plastic case, plastic fan.

Model : RDC72LHTA [3phase], RDC90LHTA [3phase]

RDC72LHTA RDC90LHTA

Wired R.C.

RDC90LHTA

UTY-RNNXM, UTY-RVNXM

UTY-RSNXM

UTY-XSZX

(EER)

4

3

2

1

0

(COP)

4

3

2

1

0

39000

100

200

300

4300 4700 5100 5500

Normal (72 Pa)

LSP mode (50 Pa)

HSP mode 1 (150 Pa)

HSP mode 2 (200 Pa)

HSP mode 3 (250 Pa)

Sta

tic p

ress

ure

(Pa)

Airflow (m3/h)

Max. 250 Pa

Rating

3.203.25 3.403.60

RDC72 RDC90 RDC72 RDC90

(RDC90L)

Page 45: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

045

Capacity

EER COP Running Current Moisture Removal

Airflow Rate (High) Static pressure range (Standard)

Sound Pressure (Cooling)

Net Dimension H x W x D

Max Pipe Length (Pre-Charge)Height Difference

CoolingHeating

Piping Connections (Small / Large)

Operation Range

Refrigerant

HeatingCooling/HeatingInput Power

Power SourceCooling

Cooling

Indoor H/M/L/QOutdoor

Indoor

Outdoor

High

Heating Cooling/Heating

Indoor / Outdoor

kW

W/W

A I/h

dB(A)

V/ Ø/Hz

kW

Specifications

Model No.Indoor unit

Outdoor unit

°CDB

m

mm

kg(lbs)

m3/hPamm

kg(lbs)mm

Dimensions (Unit : mm)

Side view (L)

Side view (R)

Rear view

Air FlowTop view

Front view

Rear view

Air FlowTop view

Front view

400/3/5020.3 (10.8-23.5)22.6 (12.0-26.5)

6.25/6.273.253.60

9.6/9.64.5

47/44/4157

4300/930050 to 250 (72)450x1587x700

100 (220)1690x930x765

215 (473)12.70/25.40

75 (20)30

-5 to 46-15 to 24R410A

400/3/5025.0 (11.2-28.0)28.0 (12.5-31.5)

7.82/8.243.203.40

11.9/12.56.0

49/46/4358

4850/1070050 to 250 (72)550x1587x700

110 (242)1690x930x765

215 (473)12.70/25.40

75 (20)30

-5 to 46-15 to 24R410A

Models : RDC72LHTA / RDC90LHTA

Model: RDC72LHTA Model: RDC90LHTA

RDC72LHTA

ROA72LALT

RDC90LHTA

ROA90LALT

Page 46: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

046

Page 47: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

047

If you want to keep a large floor as well as many rooms comfortable, we recommend you use Multi Split to build a simple system using one outdoor unit.Choose from a large lineup of indoor units that best matches your rooms.You can mix and match them at will.Build the system that is just right for you.

Control several indoor units with one outdoor unit.Build the optimum system you desire.

Multi type Line-up

2 & 3-4 Rooms Multi

8 Rooms Multi

Specifications of All Indoor Units

Multi Combination Table

Simultaneous Multi

Optional Parts for Split & Multi Split

MULTI SPLIT

048050052056058068070

Multi Split provides comfort in a variety of situations

from home to office and store.

Page 48: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

048

Multi type Line-up

Multi Split Line-up

14

4 5 5.4

18 24

6.8

30

8

45

14

Capacity range

Model code

Cooling rated capacity(kW)

Branch box

Separation tube

Outdoor unit

Outdoor unit

Outdoor unit

Outdoor unit

8 Rooms Multi Up to 8 units

4 Rooms Multi Up to 4 units

3 Rooms Multi Up to 3 units

2 Rooms Multi Up to 2 units

ROG14LAC2 ROG18LAC2

ROG18LAT3 ROG24LAT3

ROG30LAT4

ROG45LBT8

Note : 1. 2 Rooms Multi : Connectable indoor units are 2 units. ROG14LAC2 : Total capacity of indoor units connected must be between 4.0kW and 6.2kW. ROG18LAC2 : Total capacity of indoor units connected must be between 4.0kW and 7.0kW. 2. 3 Rooms Multi : Connectable indoor units are 2 to 3 units. ROG18LAT3 : Total capacity of indoor units connected must be between 4.0kW and 8.5kW. ROG24LAT3 : Total capacity of indoor units connected must be between 4.0kW and 10.5kW. 3. 4 Rooms Multi : Connectable indoor units are 3 to 4 units. ROG30LAT4 : Total capacity of indoor units connected must be between 7.9kW and 14.4kW. 4. 8 Rooms Multi : Connectable indoor units are 2 to 8 units. ROG45LBT8 : Total capacity of indoor units connected must be between 11.2kW and 18.2kW.

Page 49: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

049

Connectable Indoor unit line-up

Indoor unit features

(Branch Box)

BTU

Model name

Type

Capacity(kW) Heating

Cooling

Indoor Unit

Outdoor Unit

kW Class

7000

9000

12000

14000

18000

24000

9000

12000

14000

7000

9000

12000

14000

18000

14000

18000

7000

9000

12000

14000

18000

2.0

2.5

3.5

4.0

5.0

7.0

2.5

3.5

4.0

2.0

2.5

3.5

4.0

5.0

4.0

5.0

2.0

2.5

3.5

4.0

5.0

3 Rooms2 Rooms

4.0

4.4

5.0

5.6

5.4

6.8

6.8

8.0

4 Rooms

8.0

9.6

8 Rooms

14.0

16.0

●●●●

●●

●●●

●●●

●●●●

●●●●●●●

●●●●

●●●●●

●●●●●●●●●●●●●●●

●●●●●●●●●●●●●●●●●●●●●

●●●●●●●●●●●●●●●●●●●●●

●●●

●●●●●

●●●●●●●

●●●●●●●

●●●●●●●

●●●●●●●●●

●●●

●●●●●●●

●● ●●●●●●●

● ●●●●●●●

●●●●●●●

●●●●

●●●●

●●●

: Optional function

●●●●●●●

POWERFULPOWERFULPOWERFUL

ROG14LAC2 ROG18LAC2 ROG18LAT3 ROG24LAT3 ROG30LAT4 ROG45LBT8

RSG07/09/12/14LM

RSG18/24LF

RGG09/12/14LV

RCG07/09/12/14/18LV

RYG14/18LV

RDG07/09/12/14/18LL

RSG07/09/12/14LU

RSG07/09/12/14LMRSG07/09/12/14LURSG18/24LFRGG09/12/14LVRCG07/09/12/14/18LVRYG14/18LVRDG07/09/12/14/18LL

Page 50: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

050

2 Rooms 3 Rooms 4 Rooms

2 & 3-4 Rooms Multi

Features

Wide range of indoor units with various models7 types 25 models are lined up in the capacity range from 2 kW to 7 kW class. Wide range of needs can be met from rooms of private homes to large shops and hotels.

Space-saving installationMultiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the space-saving installation.

Flexible installationUp to max. piping length of 70 m (ROG30LAT4), max. height difference of 15 m can be supported. Multi type can be installed at large-size residence or buildings with multiple floors.

Example:Single type installation

3 outdoor units 1 outdoor unit

Multi type installation

2 Rooms : ROG14LAC2 / ROG18LAC23 Rooms : ROG18LAT3 / ROG24LAT34 Rooms : ROG30LAT4

Max. Piping Length (Each Unit):20m (ROG14LAC2 / 18LAC2), 25m (ROG18LAT3 / 24LAT3 / 30LAT4)

Max. Height:15m (ROG14LAC2 / 18LAC2 / 18LAT3 / 24LAT3 / 30LAT4)

Total Piping Length:30m (ROG14LAC2 / 18LAC2), 50m (ROG18LAT3 / 24LAT3), 70m (ROG30LAT4)

Page 51: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

051

Dimensions (Unit : mm)

Top view

540

Front view

Bottom view

Side view

288

352

19107279020

541

57

318

114

87

20

9

Air Flow

Top view

Front view

Bottom view

Side view

900

2170

0

9

40

650

370

31 12330

400

4112 94

57 114

228

Top view

Front viewSide viewBottom view

900

650

2183

0

9

40 31 12330

400

4112

94

57 114

(493

)11

4 x 3

=342

5

370

Models : ROG14LAC2 / ROG18LAC2

Models : ROG18LAT3 / ROG24LAT3

Models : ROG30LAT4

dB(A)

* Connect to connection valve by the adapter.

Power Source

Refrigerant

Piping Connections

Max. Length

Max. Height Difference

CoolingHeating

mmkg(lbs)

mm

m

°CDB

V/Ø/Hz

Outdoor unitModel No.

Between Outdoor Unit and Each Indoor Units.Between Indoor Units.

230/1/504.0 (1.4-4.4)4.4 (1.1-5.4)

3.674.2747496163

540x790x29037 (82)

Ø6.35x2

Ø9.52x2

15

1010 to 46-15 to 24R410A

30 / 20

15

10

230/1/505.4 (1.8-6.8)6.8 (2.0-8.0)

4.004.2046476567

700x900x33055 (121)

Ø6.35x3

Ø9.52x2, Ø12.7 *(Ø9.52x3)

-10 to 46-15 to 24R410A

50 / 25

230/1/506.8 (1.8-8.5)8.0 (2.0-8.8)

3.514.0048496870

700x900x33055 (121)

Ø6.35x3

Ø9.52x2, Ø12.7 *(Ø9.52x3)

15

10-10 to 46-15 to 24R410A

50 / 25

Ø6.35x4(*Ø6.35x3, Ø9.52)

Ø9.52x2, Ø12.7x2 *(Ø9.52x3, Ø12.7)

*(Ø9.52x2, Ø12.7, Ø15.88)

15

100 to 46

-10 to 24R410A

70 / 25

230/1/508.0 (3.5-10.1)9.6 (3.7-12.0)

3.604.0050516870

830x900x33068 (150)

230/1/505.0 (1.7-5.6)5.6 (1.8-6.1)

3.213.9750516364

540x790x29038 (84)

Ø6.35x2

Ø9.52x2 *(Ø9.52, Ø12.7)

15

30 / 20

1010 to 46-15 to 24R410A

Small (Liquid)

Large (Gas)

Con

nect

ion

pipe

Total / Each

Rated Capacity(min-max)

Sound Pressure(High)

Sound Power (High)

Net Dimension H x W x D Weight

EER COP

kWCoolingHeatingCoolingHeating W/W

CoolingHeatingCoolingHeating

Specifications (2 ROOMS, 3 ROOMS, 4 ROOMS)

Operation Range

ROG14LAC2 ROG18LAT3 ROG24LAT3 ROG30LAT4ROG18LAC2

Page 52: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

052

8 Rooms Multi

Features

High Efficiency & Compact

More Comfort

Innovated technologyCompact outdoor unit

High seasonal efficiencyThe actual performance is conducted under various outside temperatures depending on weather and seasons, furthermore, especially for multi system, not all the rooms are operated all the time. So over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity.Considering these, we focused on energy-saving performance which is based on actual use.Efficiency of part load performance was drastically improved by developing ALL DC and our own inverter system.

Quick comfort by optimized refrigerant controlEvery room meets the set point most quickly and comfortably by optimized refrigerant control.

1290 mm914 mm

Example of 14 kW class multi split model

New modelHeight difference

29%

High efficiency DC twin rotary compressor : A high performance, low noise, large capacity DC twin rotary compressor is used.

Heat exchanger : Reduced compact size and energy saving has been realized by utilizing high density piping design and 3-Row heat exchanger.

High efficiency large fan : New high efficiency fan is mounted.

DC fan motor : High performance and high efficiency has been realized by using a small DC fan motor.

(50% load)EER4.75EER

Frequent operation range

5

3

1

0

Part load(%)25 50 75 100 %

4.75

8 Rooms : ROG45LBT8

Refrigerant control by branch box

Meet set point

Increasecapacity

Decreasecapacity

Increasecapacity

Decreasecapacity

Meet set point

All operation start

Page 53: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

053

Features

10ºC heat operationWhen you leave, minimum heating operation is performed to maintain the room temperature (maintain at 10ºC).

Economy operationEconomy operation is energy saving, as the set temperature of indoor unit is shifted by 1°C and the maximum electric value of the outdoor unit is suppressed.

Prohibited SettingsThe remote controller operation of all indoor units comes with a lock function to prevent unapproved operations in the various rooms. The central remote controller also has a key lock function to prevent children from playing with it, etc

Weekly schedule timerThe ON/OFF setting can be set for 4 times a day. Two weekly patterns can be set to match the cooling and heating seasons.

Low noise operationUsers can choose from 4 low noise levels, depending on the installation environment. The operation time can be set using the timer.

Central Remote Controller Option

Central remote controller developed for residential applications.All indoor units can be batched controlled using simple operations. Schedule management and other functions can be used to achieve even greater energy savings.

*Note : Cross-over connections are not allowed in the refrigerant system. Group settings are not allowed.

Central & Individual ControlBatched control of up to 8 indoor units. The temperature, airflow volume, and remote control prohibition settings of all indoor units can be batched.

Easy-To-Use operation• Large backlight LED screen• Large easy-to-see operation panel

Multiple language supportCorresponds to 9 different languages (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish)

Tem

p.

Economy operation

Shift setting temp

Normal operation

Time

Set temperature

10°C

20°C

10ºC heatbutton

Indoor unit operation

ON

START

Air conditioning load factor

Capacity

Operating sound

time

100%

58dB

0

0

Heat load

down

Quiet priority low noise mode

Quiet priority setting

Monday to Friday Saturday to Sunday

7Time

Time

12 17 23

Summerseasonpattern

Winterseasonpattern

Cool Cool Cool

8 1 18 22

Cool Cool Cool

7 1213 23

Heat

Heat

Heat

7 1 18 23

Heat Heat Heat

UTY-DMMXM

Power & Transmission line

Outdoor unit

Indoor unit

R.C.

Branch box

Remote controller cable

Controllable

1multi systemMax. Controllable

8 indoor units

System configuration

Address setting is not required* When the indoor units are connected to a branch box, the address for each indoor unit is set automatically.

Transmission line

Page 54: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

054

8 Rooms Multi

Features

Large capacity connectionUp to 8 indoor units can be connected to one outdoor unit. A maximum of 130% indoor unit connectable capacity. Match any room layout.

Long piping designCan be installed in high rise condominiums or commercial buildings.

Connectableindoor unit number

Up to 8Connectable

indoor unit capacity

Ratio up to 130%

Branch box

Separation tubeOutdoor unit

Indoor unit

Total pipe length

Max. 115 m

Actual pipe lengthMax. 70 m

Height difference betweenO.U. and I.U.

Max. 30 m

Height differencebetween I.U. and I.U.

Max. 15 m

Pipe length betweenI.U. and Branch box

Max. 15 m

Branch boxSeparation tube

All flare piping connection and simple installation that minimizes wiring mistakes.

Power & Transmission lineTransmission line

Outdoor unit

Powersource

Power supply

Piping

Branch box

Simple all flare piping connection

Simple wiring connection that isnot cross connectionWiring connection is the same as single split or multi type.

Wiring mistake automatic check functionThe check operation detects wiring mistakes in advance.

Branch Box can be mounted flexibly.Allowed Branch Box Mounting Direction

HorizontalWall Mounting

VerticalWall Mounting

Install the unit with its top side facing upwards.

Install the unit with the control box facing upwards.

Hanging from the ceiling

Do not hang from the ceiling when performing a vertical installation.

Flexible Design & Easy Installation

Page 55: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

055

Branch Box : UTP-PY03A (3 branches type)

Branch Box : UTP-PY02A (2 branches type)

650

970 24 370 12

166

370

24

401

440

914

21

24

214

469

469

432

433 75

1958568

95

256 37

214

825

7570

959557

24

174154

110

134

216256

176469

469

432

433 75

1958568

95 372

148

25

7570

95

152

24

174154

110

134

216176

Outdoor Unit : ROG45LBT8

Specifications

Dimensions

m3/h

kW

kW

mm

kg(Ibs)

mm

m

°CDB

dB(A)

kW

Rated Capacity

Input Power

Power source V/ Ø/Hz

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

CoolingIndoor unit connectable capacity

Air flow rate

Net Dimensions H x W x DWeight

Piping Connections (Small / Large)

Max Pipe Length

Max Height Difference (O.U ~ I.U)

Operating range

Refrigerant

Sound pressure level

Heat exchanger fin

Cooling

Heating

8

11.2 - 18.2

230/1/50

14.0

16.0

5.20

5.07

4,650

4,800

56

58

Plate fin coil

914 x970x370

98 (217)

9.52/15.88

115 (Total)

30

-5 to 46

-15 to 24

R410A

Model name

Maximum Connectable Indoor Unit

UTP-PY03A

1 to 3 Units

230/1/50

198-264V

10

0.05

195x433x370

9

Main: 9.52x1, Branch:6.35x3

Main: 15.88x1, Branch:12.7x3

Flare

UTP-PY02A

1 to 2 Units

230/1/50

198-264V

10

0.05

195x433x370

9

Main: 9.52x1, Branch:6.35x2

Main: 15.88x1, Branch:12.7x2

Flare

Model name

Connectable indoor unit

Power source

Available voltage range

Power consumption

Running currrent

Dimensions (HxWxD)

Weight

V/Ø/Hz

W

A

mm

kgLiquid

GasConnectionpipe

Note: Specifications are based on the following conditions.Power source of specifications: 230V.

Size mm

Method

(Unit : mm)

ROG45LBT8

Page 56: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

056

Specifications

Compact wall mounted

Specifications of All Indoor Units

kW Class Power Source

Net DimensionWeightPipe Size

Sound Pressure LevelSound Power Level

Air Flow

H/M/L/Q

H

H/M/L/Q

dB(A)

dB(A)

m3/h

CoolingHeatingCoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

2.0230/1/50

35/30/28/2135/30/28/21

5353

570/520/470/330570/520/470/330

282x870x1859.5 (21)

Ø6.35/Ø9.52

2.5230/1/50

36/32/28/2136/32/28/21

5454

600/550/470/330600/550/470/330

282x870x1859.5 (21)

Ø6.35/Ø9.52

3.5230/1/50

37/34/31/2137/34/31/21

5555

660/600/530/330660/600/530/330

282x870x1859.5 (21)

Ø6.35/Ø9.52

4.0230/1/50

41/36/33/2541/36/34/27

5959

710/640/570/390710/640/590/430

282x870x1859.5 (21)

Ø6.35/Ø12.7

Indoor unit

kW Class Power Source

Net DimensionWeightPipe Size

Sound Pressure LevelSound Power Level

Air Flow

H/M/L/Q

H

H/M/L/Q

dB(A)

dB(A)

m3/h

CoolingHeatingCoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

Model No.

Wall mounted

Indoor unitModel No.

2.0230/1/50

36/32/29/2136/32/29/22

5151

560/500/430/310560/500/430/330

268x840x2038.5 (19)

Ø6.35/Ø9.52

2.5230/1/50

37/33/29/2137/33/29/22

5252

600/520/430/310600/520/430/330

268x840x2038.5 (19)

Ø6.35/Ø9.52

5.0230/1/50

43/37/33/2642/37/33/25

5858

900/740/620/550900/740/620/550

320x998x23814 (30.8)

Ø6.35/Ø12.7

3.5230/1/50

40/36/30/2140/36/31/22

5455

660/560/450/310660/560/470/330

268x840x2038.5 (19)

Ø6.35/Ø9.52

4.0230/1/50

42/38/33/2542/38/35/27

5657

730/600/530/360730/615/560/375

268x840x2038.5 (19)

Ø6.35/Ø12.7

7.0230/1/50

49/42/37/3348/42/37/33

6464

1120/900/740/6201100/900/740/620

320×998×23814 (30.8)

Ø6.35/Ø15.88

Indoor unit

kW Class Power Source

Net DimensionWeightPipe Size

Sound Pressure LevelSound Power Level

Air Flow

H/M/L/Q

H

H/M/L/Q

dB(A)

dB(A)

m3/h

CoolingHeatingCoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

Model No.

2.5230/1/50

39/34/28/2239/35/30/22

5252

530/440/360/270530/460/380/270

600x740x20014 (30.7)

Ø6.35/Ø9.52

3.5230/1/50

42/36/30/2242/38/32/22

5555

600/490/380/270600/510/410/270

600x740x20014 (30.7)

Ø6.35/Ø9.52

4.0230/1/50

44/38/31/2244/39/33/22

5656

650/520/400/270650/540/430/270

600x740x20014 (30.7)

Ø6.35/Ø12.7

Floor

RSG07LUCA RSG09LUCA RSG12LUCA RSG14LUCA

RSG07LMCA RSG09LMCA RSG18LFCARSG12LMCA RSG14LMCA RSG24LFCC

RGG09LVCA RGG12LVCA RGG14LVCA

Page 57: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

057

kW Class Power Source

Net DimensionWeightPipe Size

Sound Pressure Level

Sound Power Level

Air Flow

H/M/L/Q

H

H/M/L/Q

dB(A)

dB(A)

m3/h

Cooling

Heating

CoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

kW Class Power Source

Net DimensionWeightCassette GrillePipe Size

Sound Pressure LevelSound Power Level

Air Flow

H/M/L/Q

H

H/M/L/Q

dB(A)

dB(A)

m3/h

CoolingHeatingCoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

Floor ceiling

Compact cassette

Slim duct

4.0230/1/50

36/34/33/29 (Under ceiling)39/37/36/32 (Floor console)36/34/33/29 (Under ceiling)39/37/36/32 (Floor console)

5151

640/590/540/480640/590/540/480

199x990x65527 (60)

Ø6.35/Ø12.7

5.0230/1/50

41/38/34/32 (Under ceiling)44/41/37/35 (Floor console)41/38/34/32 (Under ceiling)44/41/37/35 (Floor console)

5555

780/700/560/500780/700/560/500

199x990x65527 (60)

Ø6.35/Ø12.7

Indoor unitModel No.

2.0230/1/50

33/31/29/2734/32/29/27

4647

540/490/440/390540/490/440/390

245x570x57015(33.1)

Ø6.35/Ø9.52

2.5230/1/50

33/31/29/2734/32/29/27

4647

540/490/440/390540/490/440/390

245x570x57015 (33.1)

Ø6.35/Ø9.52

4.0230/1/50

40/35/32/2940/37/34/29

5252

680/580/490/410700/620/550/430

245x570x57015 (33.1)

Ø6.35/Ø12.7

3.5230/1/50

37/33/31/2837/33/31/28

4949

610/530/470/410610/530/470/410

245x570x57015 (33.1)CG-UFFD

Ø6.35/Ø9.52

5.0230/1/50

42/37/33/2944/40/37/30

5456

750/610/520/410800/710/600/450

245x570x57015 (33.1)

Ø6.35/Ø12.7

Indoor unitModel No.

2.0230/1/50

28/26/25/2428/26/25/24

5757

550/490/470/440550/490/470/440

198x700x62017 (37.5)

Ø6.35/Ø9.52

2.5230/1/50

28/27/26/2528/26/25/24

5757

600/550/500/450600/550/500/450

198x700x62019 (41.8)

Ø6.35/Ø9.52

4.0230/1/50

32/30/28/2633/30/28/25

6061

800/700/600/480800/700/600/480

198x700x62019 (41.8)

Ø6.35/Ø12.7

3.5230/1/50

29/28/27/2629/28/27/24

5858

650/600/550/480650/600/550/480

198x700x62019 (41.8)

Ø6.35/Ø9.520 to 90

Standard

5.0230/1/50

32/31/30/2933/32/31/29

5859

940/880/820/750940/880/820/750

198x900x62023 (50.6)

Ø6.35/Ø12.7

Indoor unitModel No.

kW Class Power Source

Net DimensionWeightPipe SizeExternal static pressureDrain pump

Sound Pressure LevelSound Power Level

Air Flow

H/M/L/Q

H

H/M/L/Q

dB(A)

dB(A)

m3/h

CoolingHeatingCoolingHeatingCoolingHeating

Liquid/Gas

kWV/Ø/Hz

mmkg(lbs)

mm

RYG14LVTA RYG18LVTB

RCG07LVLA RCG09LVLA RCG14LVLBRCG12LVLB RCG18LVLB

RDG07LLTA RDG09LLTA RDG14LLTBRDG12LLTB RDG18LLTB

Page 58: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

058

2 Rooms Multi cooling

Multi Combination Table

77799

79

129

12

2Room

COOLING OPERATIONCooling Capacity Seasonal Data

Room 1kW

Room 2kW

Total Capacity (min-max)kW

Pdesign SEEREER Energy efficiency classkW kW

Input Power (min-max)ROG14LAC2

2.001.951.652.001.70

2.002.052.352.002.30

4.00 ( 1.4 - 4.4 )4.00 ( 1.4 - 4.4 )4.00 ( 1.4 - 4.6 )4.00 ( 1.4 - 4.5 )4.00 ( 1.4 - 4.7 )

1.09 ( 0.35 - 1.40 )1.09 ( 0.35 - 1.40 )1.05 ( 0.35 - 1.47 )1.09 ( 0.35 - 1.43 )1.05 ( 0.35 - 1.47 )

3.673.673.813.673.81

4.04.04.04.04.0

6.76.66.56.66.5

A++A++A++A++A++

Combinationof Indoor Unit

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h models •The above is the value for connecting with Wall Mounted type. •2 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 21000Btu from 14000Btu.

777799912

79

12149

121412

2Room

COOLING OPERATIONCooling Capacity Seasonal Data

Room 1kW

Room 2kW

Total Capacity (min-max)kW

Pdesign SEEREER Energy efficiency classkW kW

Input Power (min-max)ROG18LAC2

2.102.101.901.802.502.102.002.50

2.102.503.103.202.502.903.002.50

4.20 ( 1.7 - 5.2 )4.60 ( 1.7 - 5.3 )5.00 ( 1.7 - 5.6 )5.00 ( 1.8 - 5.7 )5.00 ( 1.7 - 5.6 )5.00 ( 1.7 - 5.7 )5.00 ( 1.8 - 5.8 )5.00 ( 1.7 - 5.8 )

1.24 ( 0.35 - 1.68 )1.26 ( 0.35 - 1.79 )1.55 ( 0.35 - 1.95 )1.55 ( 0.40 - 1.99 )1.56 ( 0.35 - 1.95 )1.55 ( 0.35 - 1.95 )1.55 ( 0.40 - 1.99 )1.56 ( 0.35 - 1.99 )

3.393.653.233.233.213.233.233.21

4.24.65.05.05.05.05.05.0

7.06.86.56.56.66.56.46.4

A++A++A++A++A++A++A++A++

Combinationof Indoor Unit

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h models •The above is the value for connecting with Wall Mounted type. •2 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 24000Btu from 14000Btu. •Where "14" means "wall mounted type" only models. Other types of indoor units can not be connected.

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h models •The above is the value for connecting with Wall Mounted type. •2 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The total ability of connectable indoor units is up to 36000Btu from 14000Btu. *1: When RSG18L is connected, connect at least 1 wall mounted type of 9000Btu.

3 Rooms Multi cooling

77779991212777777799

79

12149

12141214777799999

---------79

12149

12149

12

2.30 2.30 1.98 1.88 2.50 2.18 2.07 2.55 2.41 1.80 1.70 1.53 1.41 1.61 1.46 1.35 1.80 1.64

2.30 2.70 3.02 3.42 2.50 2.82 3.23 2.55 2.89 1.80 1.70 1.53 1.41 1.89 1.72 1.58 1.80 1.64

---------

1.80 2.00 2.33 2.58 1.89 2.22 2.47 1.80 2.12

4.60 ( 1.8 - 5.0 )5.00 ( 1.8 - 5.7 )5.00 ( 1.8 - 6.1 )5.30 ( 1.8 - 6.6 )5.00 ( 1.8 - 6.2 )5.00 ( 1.8 - 6.3 )5.30 ( 1.8 - 6.7 )5.10 ( 1.8 - 6.3 )5.30 ( 1.8 - 6.7 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 2.0 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 2.0 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )

1.22 ( 0.50 - 1.43 )1.35 ( 0.50 - 1.81 )1.34 ( 0.50 - 2.06 )1.34 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.60 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.60 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )

3.77 3.70 3.73 3.96 3.70 3.70 3.93 3.78 3.93 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00

4.65.05.05.35.05.05.35.15.35.45.45.45.45.45.45.45.45.4

6.36.26.26.16.26.26.16.16.16.96.96.76.76.86.76.76.86.7

A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++

2Room

3Room

COOLING OPERATIONCooling Capacity

Room 1kW

Room 2kW

Room 3kW

Total Capacity (min-max)kW

PdesignkW

SEEREER Energy efficiency classkW

Input Power (min-max)ROG18LAT3 Combinationof Indoor Unit

Seasonal Data

7777799991212127777777777799999912

79

1214189

121418121418777779999

12129999

121212

------------79

1214189

12141812149

1214

18*1

121412

2.30 2.30 2.38 2.37 2.08 2.75 2.79 2.66 2.35 3.15 3.03 2.66 2.232.14 1.98 1.82 1.63 2.03 1.88 1.74 1.56 1.76 1.63 2.27 2.11 1.95 1.77 1.97 1.84 2.27

2.30 2.70 3.42 4.13 4.52 2.75 3.41 3.94 4.35 3.15 3.67 4.04 2.232.14 1.98 1.82 1.63 2.38 2.21 2.04 1.84 2.52 2.34 2.27 2.11 1.95 1.77 2.41 2.24 2.27

------------

2.232.52 2.84 3.16 3.54 2.38 2.70 3.02 3.40 2.52 2.83 2.27 2.58 2.89 3.27 2.41 2.72 2.27

4.60 ( 1.8 - 5.0 )5.00 ( 1.8 - 5.7 )5.80 ( 1.8 - 6.1 )6.50 ( 1.8 - 7.2 )6.60 ( 1.8 - 7.8 )5.50 ( 1.8 - 6.2 )6.20 ( 1.8 - 6.8 )6.60 ( 1.8 - 7.7 )6.70 ( 1.8 - 7.9 )6.30 ( 1.8 - 7.2 )6.70 ( 1.8 - 7.8 )6.70 ( 1.8 - 7.9 )6.70 ( 1.8 - 7.4 )6.80 ( 1.8 - 7.8 )6.80 ( 1.8 - 8.1 )6.80 ( 2.0 - 8.4 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 1.8 - 8.2 )6.80 ( 2.0 - 8.4 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 1.8 - 8.3 )6.80 ( 2.0 - 8.5 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.3 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.3 )

1.20 ( 0.50 - 1.40 )1.36 ( 0.50 - 1.78 )1.70 ( 0.50 - 1.97 )1.91 ( 0.50 - 2.46 )1.91 ( 0.50 - 2.87 )1.55 ( 0.50 - 2.02 )1.90 ( 0.50 - 2.45 )1.91 ( 0.50 - 2.77 )1.91 ( 0.50 - 2.87 )1.90 ( 0.50 - 2.74 )1.91 ( 0.50 - 2.87 )1.92 ( 0.50 - 2.87 )1.89 ( 0.50 - 2.37 )1.94 ( 0.60 - 2.87 )1.93 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.93 ( 0.50 - 2.87 )1.93 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )

3.83 3.68 3.41 3.40 3.46 3.55 3.26 3.46 3.51 3.32 3.51 3.49 3.54 3.513.52 3.51 3.51 3.52 3.52 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51

4.65.05.86.56.65.56.26.66.76.36.76.76.76.86.86.86.86.86.86.86.86.86.86.86.86.86.86.86.86.8

6.36.26.16.05.96.15.96.05.95.95.95.86.46.46.36.26.16.46.26.26.16.26.26.46.26.26.16.26.26.1

A++A++A++A+A+

A++A+A+A+A+A+A+

A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++A++

2Room

3Room

COOLING OPERATIONCooling Capacity

Room 1kW

Room 2kW

Room 3kW

Total Capacity (min-max)kW

PdesignkW

SEEREER Energy efficiency classkW

Input Power (min-max)ROG24LAT3 Combinationof Indoor Unit

Seasonal Data

Page 59: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

059

2 Rooms Multi heating

77799

79

129

12

2Room

HEATING OPERATIONHeating Capacity Seasonal Data

Room 1kW

Room 2kW

Total Capacity (min-max)kW

Pdesign SCOPCOP Energy efficiency classkW kW

Input Power (min-max)ROG14LAC2

2.20 2.15 1.95 2.20 2.00

2.20 2.25 2.45 2.20 2.40

4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.5 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.5 )

1.03 ( 0.25 - 1.78 )1.03 ( 0.25 - 1.78 )1.02 ( 0.25 - 1.76 )1.03 ( 0.25 - 1.78 )1.02 ( 0.25 - 1.76 )

4.27 4.27 4.31 4.27 4.31

3.83.83.83.83.8

4.14.14.04.04.0

A+A+A+A+A+

Combinationof Indoor Unit

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h models •The above is the value for connecting with Wall Mounted type. •2 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 21000Btu from 14000Btu.

7777999

12

79

12149

121412

2Room

HEATING OPERATIONHeating Capacity Seasonal Data

Room 1kW

Room 2kW

Total Capacity (min-max)kW

Pdesign SCOPCOP Energy efficiency classkW kW

Input Power (min-max)ROG18LAC2

2.70 2.50 2.30 2.25 2.80 2.45 2.35 2.80

2.70 3.00 3.30 3.35 2.80 3.15 3.25 2.80

5.40 ( 1.8 - 6.0 )5.50 ( 1.8 - 6.0 )5.60 ( 1.8 - 6.1 )5.60 ( 1.9 - 6.2 )5.60 ( 1.8 - 6.1 )5.60 ( 1.8 - 6.2 )5.60 ( 1.9 - 6.3 )5.60 ( 1.8 - 6.3 )

1.24 ( 0.50 - 1.61 )1.36 ( 0.50 - 1.87 )1.38 ( 0.50 - 1.88 )1.35 ( 0.55 - 1.86 )1.41 ( 0.50 - 1.90 )1.38 ( 0.50 - 1.88 )1.35 ( 0.55 - 1.86 )1.34 ( 0.50 - 1.84 )

4.37 4.04 4.06 4.15 3.97 4.07 4.15 4.18

3.84.04.24.24.24.24.24.2

4.14.14.04.04.14.04.04.0

A+A+A+A+A+A+A+A+

Combinationof Indoor Unit

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h models •The above is the value for connecting with Wall Mounted type. •2 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 24000Btu from 14000Btu. •Where "14" means "wall mounted type" only models. Other types of indoor units can not be connected.

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h models •The above is the value for connecting with Wall Mounted type. •2 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 36000Btu from 14000Btu. *1: When RSG18L is connected, connect at least 1 wall mounted type for 9000Btu.

3 Rooms Multi heating

7777999

1212777777799

791214912141214777799999

---------79

12149

12149

12

2.70 2.75 2.59 2.51 3.15 2.89 2.77 3.20 3.09 2.272.14 1.98 1.83 2.03 1.89 1.75 2.27 2.12

2.70 3.25 3.71 4.29 3.15 3.51 4.03 3.20 3.71 2.272.14 1.98 1.83 2.39 2.22 2.06 2.27 2.12

---------

2.272.52 2.83 3.14 2.39 2.69 2.99 2.27 2.57

5.40 ( 2.0 - 6.1 )6.00 ( 2.0 - 6.4 )6.30 ( 2.0 - 6.5 )6.80 ( 2.0 - 7.1 )6.30 ( 2.0 - 6.5 )6.40 ( 2.0 - 6.6 )6.80 ( 2.0 - 7.2 )6.40 ( 2.0 - 6.6 )6.80 ( 2.0 - 7.3 )6.80 ( 2.0 - 7.7 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 8.0 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 7.9 )6.80 ( 2.0 - 8.0 )6.80 ( 2.0 - 7.9 )6.80 ( 2.0 - 7.9 )

1.59 ( 0.52 - 1.93 )1.87 ( 0.52 - 2.06 )1.98 ( 0.52 - 2.06 )1.92 ( 0.50 - 2.06 )1.98 ( 0.52 - 2.06 )1.99 ( 0.52 - 2.06 )1.91 ( 0.50 - 2.06 )1.98 ( 0.52 - 2.06 )1.90 ( 0.50 - 2.06 )1.62 ( 0.50 - 2.06 )1.62 ( 0.50 - 2.06 )1.59 ( 0.50 - 2.06 )1.61 ( 0.50 - 2.06 )1.60 ( 0.50 - 2.06 )1.59 ( 0.50 - 2.06 )1.60 ( 0.50 - 2.06 )1.59 ( 0.50 - 2.06 )1.59 ( 0.50 - 2.06 )

3.40 3.21 3.18 3.54 3.18 3.22 3.56 3.23 3.58 4.204.204.284.224.254.284.254.284.28

4.04.04.04.04.04.04.04.04.05.05.05.05.05.05.05.05.05.0

4.14.14.14.14.14.14.14.14.14.34.34.34.34.34.34.34.34.3

A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+

2Room

3Room

HEATING OPERATIONHeating Capacity

Room 1kW

Room 2kW

Room 3kW

Total Capacity (min-max)kW

PdesignkW

SCOPCOP Energy efficiency classkW

Input Power (min-max)ROG18LAT3 Combinationof Indoor Unit

Seasonal Data

777779999

12121277777777777999999

12

79121418912141812141877777999912129999121212

------------79

1214189

12141812149

1214

18*1

121412

2.75 2.80 2.88 2.80 2.51 3.30 3.30 3.22 2.84 3.80 3.59 3.20 2.602.522.342.161.942.382.232.06 1.85 2.081.93 2.672.492.32 2.10 2.34 2.18 2.67

2.75 3.30 4.12 4.80 5.39 3.30 4.00 4.68 5.16 3.80 4.31 4.80 2.602.522.342.161.942.812.622.42 2.18 2.962.76 2.672.492.32 2.10 2.83 2.64 2.67

------------

2.602.963.323.684.122.813.153.52 3.97 2.963.31 2.673.023.37 3.81 2.83 3.17 2.67

5.50 ( 2.0 - 6.1 )6.10 ( 2.0 - 7.0 )7.00 ( 2.0 - 7.3 )7.60 ( 2.0 - 8.3 )7.90 ( 2.0 - 8.3 )6.60 ( 2.0 - 7.4 )7.30 ( 2.0 - 7.7 )7.90 ( 2.0 - 8.3 )8.00 ( 2.0 - 8.5 )7.60 ( 2.0 - 7.8 )7.90 ( 2.0 - 8.4 )8.00 ( 2.0 - 8.6 )7.80 ( 2.0 - 8.6 )8.00 ( 2.0 - 8.8 )8.00 ( 2.0 - 8.9 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00( 2.0 - 9.0 )8.00 ( 2.0 - 9.1 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.1 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.1 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )

1.55 ( 0.52 - 1.93 )1.82 ( 0.52 - 2.52 )2.31 ( 0.52 - 2.66 )2.28 ( 0.50 - 2.87 )2.34 ( 0.50 - 2.87 )2.04 ( 0.52 - 2.68 )2.43 ( 0.52 - 2.87 )2.38 ( 0.50 - 2.87 )2.32 ( 0.50 - 2.87 )2.54 ( 0.52 - 2.87 )2.37 ( 0.50 - 2.87 )2.31 ( 0.50 - 2.87 )1.94 ( 0.50 - 2.68 )2.00( 0.50 - 2.87 )1.99 ( 0.50 - 2.80 )1.91 ( 0.50 - 2.72 )1.89 ( 0.50 - 2.70 )1.99 ( 0.50 - 2.87 )1.98 ( 0.50 - 2.87 )1.91 ( 0.50 - 2.72 )1.89 ( 0.50 - 2.69 )1.97 ( 0.50 - 2.87 )1.90 ( 0.50 - 2.70 )1.98 ( 0.50 - 2.87 )1.97 ( 0.50 - 2.87 )1.89 ( 0.50 - 2.70 )1.87 ( 0.50 - 2.68 )1.96 ( 0.50 - 2.80 )1.89 ( 0.50 - 2.69 )1.95 ( 0.50 - 2.78 )

3.55 3.35 3.03 3.33 3.38 3.24 3.00 3.32 3.45 2.99 3.33 3.46 4.024.004.024.194.234.024.044.194.234.064.214.044.064.234.284.084.234.10

4.04.04.04.04.04.04.04.04.04.04.04.05.05.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25.2

4.14.14.14.14.14.14.14.14.14.14.14.14.34.24.24.24.24.24.24.24.24.24.24.24.24.24.24.24.24.2

A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+

2Room

3Room

HEATING OPERATIONHeating Capacity

Room 1kW

Room 2kW

Room 3kW

Total Capacity (min-max)kW

PdesignkW

SCOPCOP Energy efficiency classkW

Input Power (min-max)ROG24LAT3 Combinationof Indoor Unit

Seasonal Data

Page 60: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

060

Multi Combination Table

4 Rooms Multi cooling

77777777777777779999999999999

1212121212121277777777777777777777777777799999999999

12

7779999

12121212141414181899999

12121212141414181212121214141877777777777777999999999

1212121299999999

12121212

141824121418241214182414182418249

12141824121418241418241812141824141818777779999

12121214149999

1212121414121212149999

1212121412121412

------------------------------------7912141891214181214181418912141812141814181214181491214

18*1

1214

18*2

1412141412

3Room

4Room

COOLING OPERATIONCooling Capacity Seasonal Data

Total Capacity (min-max)kW

Pdesign SEEREER Energy efficiency classkW kW

Input Power (min-max)ROG30LAT4Room 1

kW1.96 1.81 1.61 2.08 1.90 1.76 1.57 1.96 1.83 1.68 1.51 1.68 1.57 1.44 1.42 1.30 2.40 2.26 2.10 1.93 1.73 2.14 1.99 1.84 1.66 1.84 1.74 1.58 1.56 2.43 2.28 2.12 1.92 2.11 1.98 1.81 1.931.891.831.701.52 1.861.781.681.49 1.721.611.43 1.50 1.35 1.811.761.641.45 1.681.571.40 1.481.32 1.611.511.35 1.412.001.911.791.60 1.831.721.54 1.621.761.661.552.00

Room 2kW

1.96 1.81 1.61 2.34 2.14 1.98 1.77 2.62 2.43 2.24 2.01 2.81 2.61 2.39 3.19 2.92 2.40 2.26 2.10 1.93 1.73 2.53 2.36 2.18 1.97 2.73 2.58 2.34 3.12 2.43 2.28 2.12 1.92 2.64 2.48 3.05 1.931.891.831.701.52 1.861.781.681.49 1.721.611.43 1.50 1.35 2.031.961.831.64 1.881.761.58 1.661.49 2.132.001.80 1.892.001.911.791.60 1.831.721.54 1.622.081.951.852.00

Room 3kW

3.27 4.08 4.57 2.78 3.16 3.96 4.46 2.62 3.04 3.78 4.28 2.81 3.52 4.07 3.19 3.68 2.40 2.68 3.11 3.85 4.35 2.53 2.95 3.68 4.18 2.73 3.48 3.98 3.12 2.43 2.85 3.57 4.07 2.64 3.34 3.05 1.931.891.831.701.52 2.091.991.881.67 2.282.131.91 2.50 2.25 2.031.961.831.64 2.222.081.87 2.432.21 2.132.001.80 2.352.001.911.791.60 2.172.031.83 2.382.081.952.302.00

Room 4kW------------------------------------

1.932.132.412.803.43 2.092.352.763.35 2.282.653.22 2.50 3.04 2.032.322.703.27 2.222.593.15 2.432.98 2.132.493.04 2.352.002.272.633.20 2.172.533.09 2.382.082.442.302.00

7.20 ( 1.6 - 8.9 )7.70 ( 2.8 - 10.0 )7.80 ( 2.8 - 10.1 )7.20 ( 1.6 - 8.9 )7.20 ( 2.8 - 9.1 )7.70 ( 2.8 - 9.9 )

7.80 ( 2.8 - 10.1 )7.20 ( 1.6 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )

7.80 ( 2.8 - 10.1 )7.30 ( 2.8 - 9.3 )

7.70 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.80 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )7.20 ( 2.8 - 8.9 )7.20 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )

7.80 ( 2.8 - 10.1 )7.20 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )

7.80 ( 2.8 - 10.1 )7.30 ( 3.5 - 9.3 )

7.80 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.80 ( 4.7 - 10.1 )7.30 ( 2.8 - 9.2 )7.40 ( 2.8 - 9.3 )

7.80 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.40 ( 3.5 - 9.4 )

7.80 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )7.70 ( 1.6 - 9.6 )7.80 ( 1.6 - 9.8 )7.90 ( 1.6 - 9.9 )7.90 ( 2.8 - 9.9 )

8.00 ( 2.8 - 10.1 )7.90 ( 2.8 - 9.7 )7.90 ( 2.8 - 9.9 )

8.00 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )8.00 ( 2.8 - 10.0 )8.00 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.90 ( 2.8 - 9.9 )

8.00 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 4.7 - 10.1 )8.00 ( 2.8 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.0 )8.00 ( 3.5 - 10.0 )8.00 ( 3.5 - 10.0 )8.00 ( 4.7 - 10.0 )8.00 ( 3.5 - 10.0 )8.00 ( 3.5 - 10.0 )8.00 ( 4.7 - 10.0 )8.00 ( 4.7 - 10.0 )8.00 ( 3.5 - 10.0 )8.00 ( 3.5 - 10.0 )8.00 ( 4.7 - 10.0 )8.00 ( 3.5 - 10.0 )

2.22 ( 0.68 - 3.43 )2.22 ( 0.98 - 3.55 )2.19 ( 0.98 - 3.53 )2.22 ( 0.68 - 3.41 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.53 )2.22 ( 0.68 - 3.54 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.58 )2.22 ( 1.17 - 3.58 )2.20 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 0.98 - 3.42 )2.22 ( 0.98 - 3.54 )2.22 ( 0.98 - 3.57 )2.22 ( 0.98 - 3.56 )2.20 ( 1.17 - 3.54 )2.22 ( 0.98 - 3.54 )2.22 ( 0.98 - 3.57 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.56 )2.22 ( 1.27 - 3.58 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.58 )2.22 ( 1.17 - 3.57 )2.20 ( 1.17 - 3.54 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.20 ( 0.68 - 3.41 )2.22 ( 0.68 - 3.54 )2.22 ( 0.68 - 3.54 )2.22 ( 0.98 - 3.56 )2.20 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.42 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.57 )2.20 ( 1.17 - 3.55 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.57 )2.20 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.57 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.56 )

3.24 3.47 3.56 3.24 3.24 3.47 3.56 3.24 3.29 3.47 3.56 3.29 3.47 3.59 3.51 3.56 3.24 3.24 3.29 3.47 3.55 3.24 3.29 3.47 3.56 3.29 3.51 3.56 3.51 3.29 3.33 3.51 3.59 3.33 3.51 3.56 3.503.513.563.563.64 3.563.563.60 3.64 3.60 3.60 3.64 3.60 3.60 3.563.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60 3.60

7.27.77.87.27.27.77.87.27.37.77.87.37.77.97.87.97.27.27.37.77.87.27.37.77.87.37.87.97.87.37.47.87.97.47.87.97.77.87.97.98.07.97.98.08.08.08.08.08.08.07.98.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.08.0

5.95.85.85.95.95.85.85.95.95.85.85.95.85.85.75.75.95.95.95.85.85.95.95.85.85.95.85.85.75.95.95.85.85.95.85.76.26.26.16.16.06.26.16.16.06.16.16.06.06.06.26.16.16.06.16.06.06.06.06.06.06.06.06.26.16.06.06.06.06.06.06.06.06.06.0

A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+

A++A++A++A++A+

A++A++A++A+

A++A++A+A+A+

A++A++A++A+

A++A+A+A+A+A+A+A+A+

A++A++A+A+A+A+A+A+A+A+A+A+

Combinationof Indoor Unit

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h / 24:24000Btu/h models •The above is the value for connecting with Wall Mounted type. •3 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 49000Btu from 27000Btu. *1: Connection of RSG18L + RDG09L + RDG09L + RDG09L is not available. All types other than this combination can be connected. *2: Connection of RSG18L + RDG12L + RDG09L + RDG09L is not available. All types other than this combination can be connected.

Page 61: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

061

4 Rooms Multi heating

77777777777777779999999999999

1212121212121277777777777777777777777777799999999999

12

7779999

12121212141414181899999

12121212141414181212121214141877777777777777999999999

1212121299999999

12121212

141824121418241214182414182418249

12141824121418241418241812141824141818777779999

12121214149999

1212121414121212149999

1212121412121412

------------------------------------7912141891214181214181418912141812141814181214181491214

18*1

1214

18*2

1412141412

3Room

4Room

HEATING OPERATIONHeating Capacity Seasonal Data

Total Capacity (min-max)kW

Pdesign SCOPCOP Energy efficiency classkW kW

Input Power (min-max)ROG30LAT4Room 1

kW2.42 2.27 2.03 2.49 2.33 2.17 1.98 2.33 2.22 2.08 1.88 2.10 1.96 1.78 1.82 1.65 3.00 2.80 2.66 2.49 2.25 2.65 2.53 2.36 2.14 2.38 2.22 2.03 2.07 3.07 2.91 2.71 2.48 2.76 2.57 2.40 2.35 2.27 2.14 2.04 1.87 2.18 2.06 1.96 1.80 1.98 1.87 1.72 1.77 1.64 2.09 2.01 1.89 1.75 1.91 1.80 1.67 1.71 1.59 1.81 1.72 1.60 1.64 2.40 2.28 2.16 1.99 2.17 2.06 1.91 1.96 2.07 1.97 1.87 2.40

Room 2kW

2.42 2.27 2.03 2.94 2.75 2.56 2.33 3.33 3.17 2.97 2.69 3.60 3.35 3.05 3.89 3.53 3.00 2.80 2.66 2.49 2.25 3.22 3.07 2.86 2.59 3.46 3.23 2.95 3.76 3.07 2.91 2.71 2.48 3.32 3.08 3.60 2.35 2.27 2.14 2.04 1.87 2.18 2.06 1.96 1.80 1.98 1.87 1.72 1.77 1.64 2.47 2.36 2.23 2.06 2.25 2.13 1.97 2.02 1.87 2.59 2.46 2.29 2.34 2.40 2.28 2.16 1.99 2.17 2.06 1.91 1.96 2.51 2.39 2.27 2.40

Room 3kW

4.15 4.86 5.44 3.56 4.00 4.66 5.29 3.33 3.80 4.45 5.03 3.60 4.19 4.77 3.89 4.42 3.00 3.39 3.87 4.52 5.11 3.22 3.69 4.29 4.86 3.46 4.04 4.62 3.76 3.07 3.49 4.07 4.65 3.32 3.85 3.60 2.35 2.27 2.14 2.04 1.87 2.57 2.43 2.31 2.13 2.82 2.67 2.46 3.03 2.81 2.47 2.36 2.23 2.06 2.72 2.58 2.39 2.94 2.73 2.59 2.46 2.29 2.81 2.40 2.28 2.16 1.99 2.63 2.49 2.31 2.84 2.51 2.39 2.73 2.40

Room 4kW------------------------------------

2.35 2.68 3.06 3.49 4.00 2.57 2.95 3.36 3.87 2.82 3.20 3.69 3.03 3.51 2.47 2.87 3.25 3.74 2.72 3.09 3.58 2.94 3.41 2.59 2.95 3.43 2.81 2.40 2.76 3.14 3.62 2.63 2.99 3.47 2.84 2.51 2.87 2.73 2.40

9.00 ( 1.8 - 10.1 )9.40 ( 3.3 - 11.2 )9.50 ( 3.3 - 11.5 )9.00 ( 1.8 - 10.0 )9.10 ( 3.3 - 10.2 )9.40 ( 3.3 - 11.3 )9.60 ( 3.3 - 11.5 )9.00 ( 1.8 - 10.1 )9.20 ( 3.3 - 10.3 )9.50 ( 3.3 - 11.4 )9.60 ( 3.3 - 11.7 )9.30 ( 3.3 - 10.6 )9.50 ( 3.7 - 11.5 )9.60 ( 3.3 - 11.7 )9.60 ( 3.7 - 12.0 )9.60 ( 4.3 - 12.0 )9.00 ( 3.3 - 10.0 )9.00 ( 3.3 - 10.1 )9.20 ( 3.3 - 10.3 )9.50 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.7 )9.10 ( 3.3 - 10.3 )9.30 ( 3.3 - 10.5 )9.50 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.8 )9.30 ( 3.7 - 10.7 )9.50 ( 3.7 - 11.6 )9.60 ( 4.3 - 11.9 )9.60 ( 4.3 - 12.0 )9.20 ( 3.3 - 10.3 )9.30 ( 3.3 - 10.6 )9.50 ( 3.7 - 11.6 )9.60 ( 3.7 - 11.8 )9.40 ( 3.7 - 10.8 )9.50 ( 3.7 - 11.6 )9.60 ( 4.3 - 12.0 )9.40 ( 1.8 - 10.8 )9.50 ( 1.8 - 10.9 )9.50 ( 1.8 - 11.1 )9.60 ( 3.3 - 11.3 )9.60 ( 3.3 - 12.0 )9.50 ( 3.3 - 10.9 )9.50 ( 3.3 - 11.1 )9.60 ( 3.3 - 11.4 )9.60 ( 3.7 - 12.0 )9.60 ( 3.3 - 11.3 )9.60 ( 3.3 - 11.5 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.8 )9.60 ( 3.7 - 12.0 )9.50 ( 3.3 - 11.2 )9.60 ( 3.3 - 11.3 )9.60 ( 3.7 - 11.5 )9.60 ( 3.7 - 12.0 )9.60 ( 3.3 - 11.4 )9.60 ( 3.7 - 11.6 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.8 )9.60 ( 4.3 - 12.0 )9.60 ( 3.3 - 11.5 )9.60 ( 3.7 - 11.7 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.9 )9.60 ( 3.7 - 11.3 )9.60 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.6 )9.60 ( 4.3 - 12.0 )9.60 ( 3.7 - 11.5 )9.60 ( 3.7 - 11.7 )9.60 ( 4.3 - 12.0 )9.60 ( 4.3 - 11.9 )9.60 ( 3.7 - 11.6 )9.60 ( 3.7 - 11.8 )9.60 ( 4.3 - 11.9 )9.60 ( 3.7 - 11.6 )

2.66 ( 0.58 - 3.53 )2.46 ( 0.87 - 3.52 )2.47 ( 0.87 - 3.52 )2.69 ( 0.58 - 3.51 )2.64 ( 0.87 - 3.50 )2.45 ( 0.87 - 3.50 )2.46 ( 0.87 - 3.51 )2.66 ( 0.58 - 3.48 )2.62 ( 0.87 - 3.48 )2.44 ( 0.87 - 3.47 )2.45 ( 0.87 - 3.56 )2.59 ( 0.87 - 3.48 )2.42 ( 0.97 - 3.52 )2.45 ( 0.87 - 3.56 )2.40 ( 0.97 - 3.52 )2.40 ( 1.12 - 3.52 )2.69 ( 0.87 - 3.51 )2.67 ( 0.87 - 3.48 )2.63 ( 0.87 - 3.48 )2.44 ( 0.97 - 3.48 )2.45 ( 0.97 - 3.57 )2.65 ( 0.87 - 3.52 )2.61 ( 0.87 - 3.52 )2.43 ( 0.97 - 3.47 )2.44 ( 0.97 - 3.55 )2.58 ( 0.97 - 3.46 )2.41 ( 0.97 - 3.51 )2.42 ( 1.12 - 3.57 )2.40 ( 1.12 - 3.52 )2.63 ( 0.87 - 3.49 )2.59 ( 0.87 - 3.49 )2.42 ( 0.97 - 3.52 )2.43 ( 0.97 - 3.54 )2.40 ( 0.97 - 3.50 )2.40 ( 0.97 - 3.49 )2.40 ( 1.12 - 3.52 )2.43 ( 0.58 - 3.47 )2.42 ( 0.58 - 3.51 )2.41 ( 0.58 - 3.55 )2.38 ( 0.87 - 3.56 )2.27 ( 0.87 - 3.56 )2.41 ( 0.87 - 3.44 )2.40 ( 0.87 - 3.54 )2.38 ( 0.87 - 3.54 )2.27 ( 0.97 - 3.55 )2.39 ( 0.87 - 3.57 )2.36 ( 0.87 - 3.58 )2.27 ( 0.97 - 3.58 )2.34( 0.97 - 3.58 )2.27 ( 0.97 - 3.56 )2.40 ( 0.87 - 3.54 )2.39( 0.87 - 3.58 )2.37 ( 0.97 - 3.58 )2.27 ( 0.97 - 3.58 )2.38 ( 0.87 - 3.58 )2.35 ( 0.97 - 3.58 )2.27 ( 0.97 - 3.58 )2.33 ( 0.97 - 3.58 )2.27 ( 1.12 - 3.58 )2.37 ( 0.87 - 3.58 )2.34 ( 0.97 - 3.58 )2.27 ( 0.97 - 3.56 )2.32 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.58 )2.38 ( 0.97 - 3.58 )2.36 ( 0.97 - 3.58 )2.27 ( 1.12 - 3.58 )2.37 ( 0.97 - 3.58 )2.35 ( 0.97 - 3.58 )2.27 ( 1.12 - 3.58 )2.33 ( 1.12 - 3.58 )2.36 ( 0.97 - 3.58 )2.34 ( 0.97 - 3.58 )2.31 ( 1.12 - 3.58 )2.35 ( 0.97 - 3.58 )

3.38 3.82 3.85 3.35 3.45 3.84 3.90 3.38 3.51 3.89 3.92 3.59 3.93 3.92 4.00 4.00 3.35 3.37 3.50 3.89 3.92 3.43 3.56 3.91 3.93 3.60 3.94 3.97 4.00 3.50 3.59 3.93 3.95 3.92 3.96 4.00 3.873.883.944.034.233.943.964.034.234.024.074.234.104.234.004.024.054.234.034.094.234.124.234.054.104.234.144.004.034.074.234.054.094.234.124.074.104.164.09

5.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.85.86.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.26.2

3.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.83.84.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.04.0

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+A+

Combinationof Indoor Unit

Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h / 24:24000Btu/h models •The above is the value for connecting with Wall Mounted type. •3 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5 m, Height difference: 0 m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 49000Btu from 27000Btu. *1: Connection of RSG18L + RDG09L + RDG09L + RDG09L is not available. All types other than this combination can be connected. *2: Connection of RSG18L + RDG12L + RDG09L + RDG09L is not available. All types other than this combination can be connected.

Page 62: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

062

8 Rooms Multi cooling

Multi Combination Table

3Room

2Room

4Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerROG45LBT8 Combination of indoor unit

241818181414141414

14*1

1212121212

12*1

1212999999997777777

14141212121212121212121212999999999999999999999999977777777777777777777777777777

242418182418181414

14*1

2418181414

14*1

1212241818141412129

2418181414129

141414141412121212121212121414141412121212121212129999999999999

1814141414121212121212121212999999999997777

--

24182424182418

14*1

2424182418

14*1

2418242418241824182424241824182424141418141418141414121212121814141418141414121212121818141414121212129999

18181414141818141414121212121818141412121212999

24181814

---------------------------------

18141818141824181424181412182418141824181424181412241824181424181412241814121818241814241824181424181412241824182418141224181424241824

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

5.20 4.24 5.89 5.90 5.87 5.90 5.50 5.79 4.89 4.24 5.89 5.90 5.20 5.50 4.57 3.91 5.20 4.24 5.90 5.65 4.73 5.05 4.08 4.73 3.74 4.24 5.90 5.35 4.41 4.73 3.74 4.41 3.91 5.89 5.90 5.87 5.90 5.90 5.89 5.87 5.90 5.79 5.89 5.90 5.50 5.20 5.89 5.88 5.90 5.65 5.90 5.89 5.90 5.35 5.90 5.65 5.05 4.73 5.89 5.90 5.90 5.50 4.89 5.90 5.20 4.57 4.24 5.65 4.73 4.08 3.74 5.88 5.90 5.89 5.90 5.35 5.88 5.90 5.90 5.65 5.05 5.90 5.35 4.73 4.41 5.90 5.79 5.90 5.20 5.79 4.89 4.24 3.91 5.35 4.41 3.74 5.87 5.90 5.50 5.79

Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to Indoor unit) •Height difference: 0 m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to “Model Selection” in the D&T manual. *1:LMC type is not available for this combination.

7.03 5.27 4.63 5.01 3.54 3.84 4.10 4.10 4.10 4.10 3.09 3.35 3.52 3.52 3.52 3.52 3.52 3.52 2.46 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.93 2.05 2.05 2.05 2.05 2.05 2.05 3.60 3.84 3.04 3.15 3.35 3.09 3.04 3.30 3.52 3.09 3.35 3.52 3.52 2.34 2.30 2.49 2.64 2.46 2.34 2.53 2.64 2.46 2.64 2.64 2.64 2.32 2.51 2.47 2.64 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.79 1.91 1.82 1.96 2.05 1.79 1.93 1.91 2.05 2.05 1.93 2.05 2.05 2.05 1.84 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 1.77 1.92 2.05 2.05

7.03 7.03 4.63 5.01 6.07 4.94 5.27 4.10 4.10 4.10 6.18 5.01 5.27 4.10 4.10 4.10 3.52 3.52 6.54 5.27 5.27 4.10 4.10 3.52 3.52 2.64 6.64 5.27 5.27 4.10 4.10 3.52 2.64 3.60 3.84 3.54 3.67 3.90 3.09 3.04 3.30 3.52 3.09 3.35 3.52 3.52 3.64 3.57 3.87 4.10 3.28 3.12 3.37 3.52 3.28 3.52 3.52 3.52 2.32 2.51 2.47 2.64 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 4.59 3.82 3.64 3.93 4.10 3.07 3.32 3.28 3.52 3.52 3.32 3.52 3.52 3.52 2.36 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.77 1.92 2.05 2.05

---------------------------------

4.63 3.84 4.55 4.72 3.90 4.63 6.07 4.94 4.10 6.18 5.01 4.10 3.52 4.67 6.12 4.97 4.10 4.90 6.23 5.05 4.10 6.54 5.27 4.10 3.52 6.18 5.01 6.59 5.27 4.10 6.68 5.27 4.10 3.52 7.03 5.27 4.10 3.52 4.59 4.91 6.24 5.05 4.10 6.12 4.97 6.54 5.27 4.10 6.63 5.27 4.10 3.52 6.29 5.27 6.68 5.27 7.03 5.27 4.10 3.52 7.03 5.27 4.10 6.07 6.59 5.27 7.03

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

--

6.18 5.01 6.07 6.59 5.27 7.03 5.27 4.10 6.18 6.68 5.27 7.03 5.27 4.10 7.03 5.27 6.54 7.03 5.27 7.03 5.27 7.03 5.27 7.03 6.64 7.03 5.27 7.03 5.27 7.03 7.03 3.60 3.84 4.55 3.67 3.90 4.63 3.54 3.84 4.10 3.09 3.35 3.52 3.52 4.67 3.57 3.87 4.10 4.90 3.64 3.93 4.10 3.28 3.52 3.52 3.52 4.63 5.01 3.84 4.10 4.10 3.35 3.52 3.52 3.52 2.64 2.64 2.64 2.64 4.59 4.91 3.64 3.93 4.10 4.59 4.97 3.82 4.10 4.10 3.32 3.52 3.52 3.52 4.72 5.27 3.90 4.10 3.52 3.52 3.52 3.52 2.64 2.64 2.64 6.07 4.94 5.27 4.10

14.06 12.30 15.45 15.03 15.68 15.37 14.64 15.23 13.47 12.30 15.45 15.04 14.06 14.65 12.89 11.72 14.07 12.31 15.54 14.94 13.18 13.77 12.01 13.19 11.43 12.31 15.21 14.35 12.59 13.18 11.42 12.60 11.72 15.45 15.37 15.68 15.21 15.04 15.45 15.69 15.38 15.24 15.45 15.05 14.66 14.08 15.33 15.57 15.21 14.94 15.54 15.33 14.87 14.36 15.55 14.95 13.78 13.20 15.45 15.04 15.38 14.65 13.48 15.05 14.07 12.90 12.32 14.95 13.19 12.02 11.44 15.56 15.54 15.33 14.87 14.35 15.57 15.21 15.54 14.94 13.77 15.21 14.36 13.19 12.61 15.21 15.23 15.04 14.06 15.24 13.48 12.31 11.73 14.36 12.60 11.43 15.68 15.37 14.64 15.23

Page 63: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

063

8 Rooms Multi cooling

Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to Indoor unit) •Height difference: 0 m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to “Model Selection” in the D&T manual.

4Room

5Room

6Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerROG45LBT8 Combination of indoor unit

777777777

121299999999999999999997777777777777777777777777777777777777777777777777777777777777799999777

777777777

12121212129999999999999999

121212121299999999999999999997777777777777777777777777777777777777799999999

14141212129977

12121212121412121212129999999999

141212121214141212121212999999999999

141412121212121299999999999997777777777777777799999999

1814241814241824181212141212141414121212141412121299999

1414121212141414141212121814141212121299999

1414181414121212181414141212121299999

181414141212121299999777799999

1299

---------

1412141412141814181412181418141224181412914141814121814181418141218181424181412241814129181418181424141218241814241814122418141291824181424181412241814129241814121212999121212

--------------------------------------------------------------------------------------------

141214129121412

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.89 4.24 5.50 4.57 3.91 5.05 4.08 4.73 3.74 5.87 5.89 5.88 5.89 5.90 5.89 5.87 5.90 5.89 5.90 5.90 5.89 5.90 5.90 5.90 5.65 5.89 5.90 5.50 5.20 4.73 5.88 5.89 5.88 5.90 5.90 5.87 5.90 5.89 5.90 5.90 5.90 5.79 5.88 5.90 5.90 5.88 5.90 5.65 5.35 5.90 5.79 5.20 4.89 4.41 5.89 5.90 5.87 5.90 5.90 5.87 5.79 5.50 5.89 5.88 5.90 5.65 5.89 5.90 5.35 5.05 5.90 5.50 4.89 4.57 4.08 5.90 5.89 5.90 5.35 5.90 5.65 5.05 4.73 5.90 5.20 4.57 4.24 3.74 5.79 4.89 4.24 3.91 5.87 5.89 5.89 5.90 5.90 5.88 5.89 5.90

2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 3.04 3.09 2.30 2.34 2.46 2.32 2.28 2.36 2.32 2.47 2.51 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 1.79 1.82 1.79 1.91 1.93 1.77 1.84 1.80 1.92 1.83 1.95 2.05 1.79 1.91 1.96 1.79 1.93 2.05 2.05 1.83 2.05 2.05 2.05 2.05 1.80 1.92 1.77 1.84 1.95 1.77 2.05 2.05 1.82 1.79 1.93 2.05 1.82 1.96 2.05 2.05 1.92 2.05 2.05 2.05 2.05 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 1.78 1.80 1.83

2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 3.04 3.09 3.07 3.12 3.27 2.32 2.28 2.36 2.32 2.47 2.51 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 3.07 3.12 3.07 3.28 3.32 2.28 2.36 2.32 2.47 2.36 2.51 2.64 2.30 2.46 2.53 2.30 2.49 2.64 2.64 2.36 2.64 2.64 2.64 2.64 1.80 1.92 1.77 1.84 1.95 1.77 2.05 2.05 1.82 1.79 1.93 2.05 1.82 1.96 2.05 2.05 1.92 2.05 2.05 2.05 2.05 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 2.30 2.32 2.36

5.27 4.10 7.03 5.27 4.10 7.03 5.27 7.03 5.27 3.04 3.09 3.57 3.12 3.27 3.60 3.54 3.67 3.09 3.30 3.34 3.64 3.87 3.28 3.37 3.52 2.32 2.51 2.64 2.64 2.64 3.57 3.64 3.07 3.28 3.32 3.54 3.67 3.60 3.84 3.15 3.35 3.52 4.59 3.82 3.93 3.07 3.32 3.52 3.52 2.36 2.64 2.64 2.64 2.64 3.60 3.84 4.55 3.67 3.90 3.04 3.52 3.52 4.67 3.57 3.87 4.10 3.12 3.37 3.52 3.52 2.47 2.64 2.64 2.64 2.64 4.91 3.64 3.93 4.10 3.28 3.52 3.52 3.52 2.51 2.64 2.64 2.64 2.64 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 3.06 2.32 2.36

---------

3.54 3.09 3.57 3.63 3.27 3.60 4.55 3.67 4.63 3.84 3.34 4.67 3.87 4.90 3.93 3.52 6.18 5.01 4.10 3.52 2.64 3.57 3.64 4.59 3.82 3.32 4.55 3.67 4.63 3.84 4.72 3.90 3.52 4.59 4.90 3.93 6.12 4.97 4.10 3.52 6.29 5.27 4.10 3.52 2.64 4.63 3.84 4.55 4.72 3.90 6.07 4.10 3.52 4.67 6.12 4.97 4.10 6.23 5.05 4.10 3.52 6.59 5.27 4.10 3.52 2.64 4.91 6.24 5.05 4.10 6.54 5.27 4.10 3.52 6.68 5.27 4.10 3.52 2.64 7.03 5.27 4.10 3.52 3.04 3.09 2.34 2.46 2.51 3.06 3.09 3.15

--------------------------------------------------------------------------------------------

3.54 3.09 3.63 3.27 2.51 3.06 3.60 3.15

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.10 4.10 3.52 3.52 3.52 2.64 2.64 2.05 2.05 3.04 3.09 3.07 3.12 3.27 3.60 3.04 3.15 3.09 3.30 3.34 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 3.57 3.12 3.07 3.28 3.32 3.54 3.67 3.09 3.30 3.15 3.35 3.52 2.30 2.46 2.53 2.30 2.49 2.64 2.64 2.36 2.64 2.64 2.64 2.64 3.60 3.84 3.04 3.15 3.35 3.04 3.52 3.52 2.34 2.30 2.49 2.64 2.34 2.53 2.64 2.64 2.47 2.64 2.64 2.64 2.64 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 2.30 2.32 2.36

13.47 12.30 14.65 12.89 11.72 13.77 12.01 13.18 11.42 15.69 15.46 15.57 15.34 15.55 15.45 15.69 15.21 15.45 15.38 15.05 15.33 15.21 15.55 14.88 14.96 15.45 15.05 14.66 14.08 13.20 15.57 15.33 15.57 15.55 15.22 15.68 15.21 15.45 15.38 15.21 15.05 15.25 15.57 15.54 14.87 15.57 15.21 14.95 14.37 15.21 15.24 14.07 13.49 12.61 15.45 15.37 15.68 15.21 15.04 15.69 15.24 14.66 15.33 15.57 15.21 14.94 15.33 14.87 14.36 13.78 15.38 14.65 13.48 12.90 12.02 15.54 15.33 14.87 14.35 15.54 14.94 13.77 13.19 15.04 14.06 12.89 12.31 11.43 15.23 13.47 12.30 11.72 15.69 15.46 15.34 15.55 15.05 15.57 15.45 15.22

Page 64: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

064

8 Rooms Multi cooling

Multi Combination Table

6Room

7Room

8Room

COOLING OPERATIONCooling Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerROG45LBT8 Combination of indoor unit

77777777777777777777777777777777777777777777777777777777777777777777

99977777777777777777777777777777777777777797777777777777777777777777

999

129999999999777777777777777777777777777799977777777777777777777777

999

12121299999999

121212999999999777777777777777799999977777777777777777777

9991212121412121299991412121414121212999914141212129999977777799999999997777777777777777

18129121412141814121814129141412181418141218141291814181412241814129241814129799999912999121299997777797777

------------------------------------------9129141291214129141218141291814129799777

---------------------------------------------------------------991297

5.88 5.90 5.79 5.87 5.88 5.89 5.89 5.87 5.90 5.90 5.89 5.90 5.90 5.50 5.88 5.89 5.90 5.87 5.90 5.89 5.90 5.90 5.90 5.90 5.65 5.20 5.89 5.90 5.90 5.90 5.79 5.88 5.90 5.65 5.35 4.89 5.89 5.90 5.35 5.05 4.57 4.24 5.88 5.87 5.89 5.87 5.89 5.90 5.88 5.89 5.90 5.90 5.88 5.89 5.87 5.90 5.90 5.90 5.89 5.90 5.90 5.65 5.35 5.87 5.89 5.88 5.90 5.90

1.79 1.93 2.05 1.77 1.79 1.82 1.80 1.77 1.83 1.92 1.82 1.93 1.96 2.05 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 1.78 1.77 1.82 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

2.30 2.49 2.64 1.77 1.79 1.82 1.80 1.77 1.83 1.92 1.82 1.93 1.96 2.05 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 1.77 1.82 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

2.30 2.49 2.64 3.04 3.07 3.12 2.32 2.28 2.36 2.47 2.34 2.49 2.53 2.64 3.07 3.12 3.28 2.28 2.36 2.32 2.47 2.51 2.46 2.53 2.64 2.64 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 2.28 2.32 2.46 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

2.30 2.49 2.64 3.04 3.07 3.12 3.60 3.04 3.15 3.30 2.34 2.49 2.53 2.64 3.57 3.12 3.28 3.54 3.67 3.09 3.30 3.35 2.46 2.53 2.64 2.64 3.60 3.84 3.15 3.35 3.52 2.30 2.49 2.64 2.64 2.64 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 2.28 2.32 2.46 2.30 2.32 2.36 2.49 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

4.59 3.32 2.64 3.04 3.57 3.12 3.60 4.55 3.67 3.30 4.67 3.87 3.37 2.64 3.57 3.64 3.28 4.55 3.67 4.63 3.84 3.35 4.90 3.93 3.52 2.64 4.63 3.84 4.72 3.90 3.52 6.12 4.97 4.10 3.52 2.64 6.24 5.05 4.10 3.52 2.64 2.05 2.30 2.28 2.34 2.28 2.32 2.46 3.07 2.32 2.36 2.49 3.07 3.12 2.28 2.36 2.47 2.53 1.80 1.92 1.95 2.05 2.05 2.28 1.80 1.79 1.84 1.92

------------------------------------------

2.30 3.04 2.34 3.54 3.09 2.46 3.07 3.60 3.15 2.49 3.57 3.12 4.55 3.67 3.30 2.53 4.63 3.84 3.35 2.64 2.05 2.28 2.32 1.79 1.84 1.92

---------------------------------------------------------------

2.28 2.32 3.07 2.36 1.92

2.30 2.49 2.64 3.04 2.30 2.34 2.32 2.28 2.36 2.47 2.34 2.49 2.53 2.64 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92

15.57 15.22 15.25 15.69 15.57 15.34 15.45 15.69 15.21 15.38 15.33 15.21 14.88 14.66 15.57 15.33 15.55 15.68 15.21 15.45 15.38 15.05 15.54 14.87 14.95 14.07 15.45 15.37 15.21 15.04 15.24 15.57 15.21 14.94 14.36 13.48 15.33 14.87 14.35 13.77 12.89 12.30 15.57 15.69 15.34 15.69 15.45 15.55 15.57 15.45 15.21 15.21 15.57 15.33 15.68 15.21 15.38 14.87 15.45 15.37 15.04 14.94 14.35 15.69 15.45 15.57 15.21 15.37

Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to Indoor unit) •Height difference: 0 m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to “Model Selection” in the D&T manual.

Page 65: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

065

8 Rooms Multi heating

3Room

2Room

4Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerROG45LBT8 Combination of indoor unit

241818181414141414

14*1

1212121212

12*1

1212999999997777777

14141212121212121212121212999999999999999999999999977777777777777777777777777777

242418182418181414

14*1

2418181414

14*1

1212241818141412129

2418181414129

141414141412121212121212121414141412121212121212129999999999999

1814141414121212121212121212999999999997777

--

24182424182418

14*1

2424182418

14*1

2418242418241824182424241824182424141418141418141414121212121814141418141414121212121818141414121212129999

18181414141818141414121212121818141412121212999

24181814

---------------------------------

18141818141824181424181412182418141824181424181412241824181424181412241814121818241814241824181424181412241824182418141224181424241824

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

5.07 4.21 5.98 5.43 5.98 5.70 5.11 5.23 4.75 4.21 5.98 5.43 5.07 5.11 4.46 4.00 5.07 4.21 5.87 5.16 4.60 4.91 4.10 4.60 3.90 4.21 5.56 5.08 4.33 4.60 3.90 4.33 4.00 5.98 5.70 5.98 5.98 5.43 5.98 5.98 5.70 5.23 5.98 5.43 5.11 5.07 5.98 5.98 5.56 5.16 5.87 5.98 5.32 5.08 5.87 5.16 4.91 4.60 5.98 5.43 5.70 5.11 4.75 5.43 5.07 4.46 4.21 5.16 4.60 4.10 3.90 5.98 5.87 5.98 5.32 5.08 5.98 5.56 5.87 5.16 4.91 5.56 5.08 4.60 4.33 5.98 5.23 5.43 5.07 5.23 4.75 4.21 4.00 5.08 4.33 3.90 5.98 5.70 5.11 5.23

7.91 5.86 5.32 5.79 4.26 4.59 4.78 4.75 4.80 4.80 3.58 3.84 3.96 3.94 3.96 3.96 3.96 3.96 2.85 2.97 2.99 2.99 2.99 2.99 2.99 2.99 2.28 2.37 2.37 2.37 2.37 2.37 2.37 4.30 4.55 3.53 3.61 3.80 3.59 3.52 3.79 3.92 3.58 3.84 3.94 3.96 2.72 2.66 2.87 2.96 2.86 2.71 2.90 2.98 2.85 2.97 2.99 2.99 2.71 2.90 2.86 2.98 2.99 2.89 2.99 2.99 2.99 2.97 2.99 2.99 2.99 2.14 2.26 2.14 2.29 2.36 2.13 2.29 2.25 2.35 2.37 2.28 2.37 2.37 2.37 2.25 2.35 2.29 2.37 2.35 2.37 2.37 2.37 2.37 2.37 2.37 2.11 2.27 2.36 2.35

7.91 7.91 5.32 5.79 7.02 5.61 5.84 4.75 4.80 4.80 7.15 5.68 5.86 4.78 4.80 4.80 3.96 3.96 7.54 5.83 5.86 4.80 4.80 3.96 3.96 2.99 7.61 5.85 5.86 4.80 4.80 3.96 2.99 4.30 4.55 4.28 4.38 4.61 3.59 3.52 3.79 3.92 3.58 3.84 3.94 3.96 4.37 4.27 4.60 4.75 3.78 3.59 3.85 3.94 3.77 3.94 3.96 3.96 2.71 2.90 2.86 2.98 2.99 2.89 2.99 2.99 2.99 2.97 2.99 2.99 2.99 5.28 4.57 4.33 4.65 4.77 3.56 3.82 3.76 3.93 3.96 3.81 3.96 3.96 3.96 2.84 2.97 2.88 2.99 2.96 2.99 2.99 2.99 2.98 2.99 2.99 2.11 2.27 2.36 2.35

---------------------------------

5.24 4.55 5.22 5.34 4.61 5.32 7.02 5.61 4.75 7.15 5.68 4.78 3.96 5.33 7.04 5.62 4.75 5.60 7.17 5.69 4.78 7.54 5.83 4.80 3.96 7.16 5.68 7.55 5.83 4.80 7.65 5.86 4.80 3.96 7.86 5.86 4.80 3.96 5.28 5.58 7.14 5.67 4.77 7.10 5.65 7.52 5.82 4.80 7.61 5.85 4.80 3.96 7.51 5.81 7.63 5.86 7.84 5.86 4.80 3.96 7.89 5.86 4.80 7.03 7.57 5.84 7.83

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

--

7.18 5.79 7.02 7.57 5.84 7.82 5.86 4.80 7.15 7.67 5.86 7.87 5.86 4.80 7.91 5.86 7.54 7.87 5.86 7.91 5.86 7.91 5.86 7.91 7.61 7.90 5.86 7.91 5.86 7.91 7.91 4.30 4.55 5.22 4.38 4.61 5.32 4.26 4.59 4.75 3.58 3.84 3.94 3.96 5.33 4.27 4.60 4.75 5.60 4.35 4.66 4.78 3.77 3.94 3.96 3.96 5.30 5.68 4.58 4.78 4.80 3.83 3.96 3.96 3.96 2.97 2.99 2.99 2.99 5.28 5.58 4.33 4.65 4.77 5.26 5.65 4.56 4.77 4.80 3.81 3.96 3.96 3.96 5.56 5.81 4.63 4.80 3.92 3.96 3.96 3.96 2.98 2.99 2.99 7.03 5.61 5.84 4.75

15.82 13.77 17.82 17.38 18.31 17.77 16.46 17.32 15.46 14.40 17.89 17.19 15.68 16.59 14.62 13.56 15.83 13.78 17.93 16.67 14.71 15.70 13.65 14.86 12.81 13.89 17.51 16.12 14.09 15.08 13.03 14.24 13.27 18.13 18.20 18.24 17.71 17.62 17.82 18.32 17.77 17.33 17.90 17.20 16.60 15.84 17.76 18.25 17.68 17.22 17.84 17.83 17.11 16.48 17.94 16.67 15.71 14.87 17.88 17.17 17.85 16.56 15.58 17.27 15.80 14.74 13.90 16.77 14.83 13.77 12.93 17.98 17.99 17.94 17.26 16.67 18.05 17.41 18.09 16.87 15.93 17.51 16.13 15.09 14.25 18.15 16.95 17.42 16.02 17.08 15.18 14.12 13.28 16.23 14.21 13.15 18.28 17.73 16.40 17.27

Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to Indoor unit) •Height difference: 0 m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to “Model Selection” in the D&T manual. *1:LMC type is not available for this combination.

Page 66: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

066

8 Rooms Multi heating

Multi Combination Table

4Room

5Room

6Room

HEATING OPERATIONHeating Capacity

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerROG45LBT8 Combination of indoor unit

777777777

121299999999999999999997777777777777777777777777777777777777777777777777777777777777799999777

777777777

12121212129999999999999999

121212121299999999999999999997777777777777777777777777777777777777799999999

14141212129977

12121212121412121212129999999999

141212121214141212121212999999999999

141412121212121299999999999997777777777777777799999999

1814241814241824181212141212141414121212141412121299999

1414121212141414141212121814141212121299999

1414181414121212181414141212121299999

181414141212121299999777799999

1299

---------

14121414121418141814121814181412241814129

14141814121814181418141218181424181412241814129

18141818142414121824181424181412241814129

1824181424181412241814129

241814121212999

121212

--------------------------------------------------------------------------------------------

141214129121412

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.75 4.21 5.11 4.46 4.00 4.91 4.10 4.60 3.90 5.98 5.98 5.98 5.98 5.87 5.98 5.98 5.98 5.98 5.70 5.43 5.98 5.56 5.87 5.32 5.16 5.98 5.43 5.11 5.07 4.60 5.98 5.98 5.98 5.87 5.56 5.98 5.98 5.98 5.70 5.98 5.43 5.23 5.98 5.87 5.32 5.98 5.56 5.16 5.08 5.98 5.23 5.07 4.75 4.33 5.98 5.70 5.98 5.98 5.43 5.98 5.23 5.11 5.98 5.98 5.56 5.16 5.98 5.32 5.08 4.91 5.70 5.11 4.75 4.46 4.10 5.87 5.98 5.32 5.08 5.87 5.16 4.91 4.60 5.43 5.07 4.46 4.21 3.90 5.23 4.75 4.21 4.00 5.98 5.98 5.98 5.87 5.43 5.98 5.98 5.98

2.37 2.37 2.36 2.37 2.37 2.37 2.37 2.37 2.37 3.51 3.58 2.66 2.71 2.85 2.67 2.66 2.72 2.71 2.86 2.89 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 2.10 2.14 2.13 2.25 2.28 2.09 2.14 2.13 2.26 2.25 2.28 2.35 2.13 2.25 2.29 2.12 2.28 2.35 2.37 2.17 2.35 2.37 2.37 2.37 2.12 2.25 2.11 2.16 2.28 2.11 2.35 2.36 2.16 2.11 2.27 2.35 2.15 2.34 2.36 2.37 2.27 2.36 2.37 2.37 2.37 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.12 2.13 2.17

2.37 2.37 2.36 2.37 2.37 2.37 2.37 2.37 2.37 3.51 3.58 3.52 3.59 3.77 2.67 2.66 2.72 2.71 2.86 2.89 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 3.51 3.57 3.56 3.76 3.81 2.64 2.71 2.69 2.85 2.84 2.88 2.96 2.69 2.84 2.89 2.68 2.88 2.97 2.98 2.74 2.96 2.99 2.99 2.99 2.12 2.25 2.11 2.16 2.28 2.11 2.35 2.36 2.16 2.11 2.27 2.35 2.15 2.34 2.36 2.37 2.27 2.36 2.37 2.37 2.37 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.68 2.69 2.74

5.86 4.80 7.87 5.86 4.80 7.91 5.86 7.91 5.86 3.51 3.58 4.27 3.59 3.77 4.28 4.26 4.37 3.58 3.78 3.83 4.36 4.59 3.78 3.84 3.93 2.70 2.89 2.97 2.99 2.99 4.25 4.33 3.56 3.76 3.81 4.24 4.34 4.32 4.57 3.76 3.82 3.92 5.27 4.56 4.64 3.55 3.81 3.93 3.95 2.74 2.96 2.99 2.99 2.99 4.30 4.55 5.23 4.38 4.61 3.52 3.92 3.94 5.34 4.28 4.61 4.75 3.60 3.92 3.95 3.96 2.86 2.98 2.99 2.99 2.99 5.58 4.34 4.65 4.77 3.77 3.93 3.96 3.96 2.89 2.99 2.99 2.99 2.99 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 3.55 2.69 2.74

---------

4.26 3.58 4.27 4.35 3.77 4.28 5.21 4.37 5.30 4.58 3.83 5.32 4.59 5.59 4.65 3.93 7.14 5.67 4.77 3.96 2.99 4.25 4.33 5.26 4.56 3.81 5.18 4.34 5.28 4.57 5.56 4.63 3.92 5.27 5.57 4.64 7.08 5.64 4.76 3.95 7.24 5.81 4.79 3.96 2.99 5.25 4.55 5.23 5.35 4.61 7.03 4.75 3.94 5.34 7.05 5.62 4.75 7.18 5.80 4.78 3.96 7.56 5.83 4.80 3.96 2.99 5.58 7.15 5.68 4.77 7.52 5.82 4.80 3.96 7.63 5.86 4.80 3.96 2.99 7.83 5.86 4.80 3.96 3.51 3.57 2.71 2.85 2.89 3.55 3.56 3.62

--------------------------------------------------------------------------------------------

4.25 3.57 4.34 3.77 2.89 3.55 4.31 3.62

----------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------

4.80 4.80 3.94 3.96 3.96 2.99 2.99 2.37 2.37 3.51 3.58 3.52 3.59 3.77 4.28 3.52 3.60 3.58 3.78 3.83 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 4.25 3.57 3.56 3.76 3.81 4.24 4.34 3.57 3.77 3.76 3.82 3.92 2.69 2.84 2.89 2.68 2.88 2.97 2.98 2.74 2.96 2.99 2.99 2.99 4.30 4.55 3.53 3.62 3.80 3.52 3.92 3.94 2.72 2.67 2.87 2.96 2.72 2.96 2.98 2.99 2.86 2.98 2.99 2.99 2.99 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.68 2.69 2.74

15.40 14.34 16.53 14.56 13.50 15.64 13.59 15.02 12.97 18.32 17.90 18.26 17.84 17.95 18.19 18.30 17.77 17.88 17.86 17.28 17.82 17.77 17.92 17.19 16.78 17.94 17.25 16.67 15.92 14.95 18.37 17.95 18.06 18.10 17.52 18.40 17.88 17.99 18.01 18.16 17.43 17.09 18.04 18.07 17.34 18.11 17.49 16.97 16.24 17.63 17.05 16.12 15.30 14.33 18.10 18.16 18.21 17.68 17.58 18.29 17.28 16.54 17.73 18.22 17.64 17.16 17.80 17.36 16.43 15.65 17.81 16.51 15.52 14.68 13.71 17.95 17.91 17.22 16.62 18.05 16.81 15.87 15.03 17.38 15.96 14.90 14.06 13.09 17.22 15.34 14.28 13.44 18.36 17.94 17.88 18.00 17.33 18.12 18.05 17.63

Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to Indoor unit) •Height difference: 0 m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to “Model Selection” in the D&T manual.

Page 67: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

067

8 Rooms Multi heating

6Room

7Room

8Room

HEATING OPERATION

Room 1KW

Room 2KW

Room 4KW

Room 5KW

Room 6KW

Room 7KW

Room 8KW

Room 3KW

TotalKW KW

Input powerROG45LBT8Heating CapacityCombination

of indoor unit

77777777777777777777777777777777777777777777777777777777777777777777

99977777777777777777777777777777777777777797777777777777777777777777

999

129999999999777777777777777777777777777799977777777777777777777777

999

12121299999999

121212999999999777777777777777799999977777777777777777777

999

121212141212129999

14121214141212129999

14141212129999977777799999999997777777777777777

18129121412141814121814129141412181418141218141291814181412241814129241814129799999912999121299997777797777

------------------------------------------9129141291214129141218141291814129799777

---------------------------------------------------------------991297

5.98 5.56 5.23 5.98 5.98 5.98 5.98 5.98 5.98 5.70 5.98 5.56 5.32 5.11 5.98 5.98 5.87 5.98 5.98 5.98 5.70 5.43 5.87 5.32 5.16 5.07 5.98 5.70 5.98 5.43 5.23 5.98 5.56 5.16 5.08 4.75 5.98 5.32 5.08 4.91 4.46 4.21 5.98 5.98 5.98 5.98 5.98 5.87 5.98 5.98 5.98 5.56 5.98 5.98 5.98 5.98 5.70 5.32 5.98 5.70 5.43 5.16 5.08 5.98 5.98 5.98 5.98 5.70

2.12 2.28 2.35 2.11 2.11 2.15 2.12 2.11 2.16 2.27 2.15 2.27 2.30 2.36 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.12 2.10 2.15 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

2.68 2.87 2.96 2.11 2.11 2.15 2.12 2.11 2.16 2.27 2.15 2.27 2.30 2.36 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.10 2.15 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

2.68 2.87 2.96 3.52 3.53 3.60 2.67 2.66 2.72 2.86 2.72 2.86 2.90 2.97 3.51 3.58 3.77 2.65 2.71 2.70 2.85 2.89 2.84 2.89 2.97 2.99 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.63 2.69 2.84 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

2.68 2.87 2.96 3.52 3.53 3.60 4.29 3.52 3.61 3.78 2.72 2.86 2.90 2.97 4.26 3.58 3.77 4.25 4.35 3.57 3.77 3.82 2.84 2.89 2.97 2.99 4.31 4.56 3.62 3.81 3.92 2.67 2.87 2.96 2.98 2.99 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.63 2.69 2.84 2.67 2.68 2.73 2.87 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

5.25 3.81 2.96 3.52 4.28 3.60 4.29 5.21 4.37 3.78 5.33 4.60 3.84 2.97 4.26 4.34 3.77 5.19 4.35 5.28 4.57 3.82 5.57 4.64 3.93 2.99 5.26 4.56 5.36 4.62 3.92 7.06 5.63 4.76 3.95 2.99 7.16 5.68 4.78 3.96 2.99 2.37 2.67 2.65 2.71 2.63 2.69 2.84 3.53 2.68 2.73 2.87 3.52 3.58 2.65 2.71 2.85 2.89 2.13 2.25 2.28 2.35 2.36 2.64 2.12 2.11 2.15 2.25

------------------------------------------

2.67 3.51 2.71 4.23 3.56 2.84 3.53 4.30 3.61 2.87 4.26 3.58 5.19 4.36 3.78 2.89 5.26 4.56 3.81 2.96 2.36 2.64 2.68 2.11 2.15 2.25

---------------------------------------------------------------

2.64 2.68 3.52 2.72 2.25

2.68 2.87 2.96 3.52 2.66 2.71 2.67 2.66 2.72 2.86 2.72 2.86 2.90 2.97 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25

18.10 17.57 17.16 18.29 18.23 17.81 18.16 18.27 17.74 17.82 17.79 17.73 17.15 16.61 18.34 17.92 18.06 18.38 17.85 17.96 17.97 17.39 18.03 17.30 16.92 16.07 18.07 18.12 17.65 17.54 17.23 18.19 17.60 17.11 16.38 15.46 17.88 17.18 16.57 15.81 14.84 14.22 18.16 18.33 17.85 18.40 18.02 18.11 18.20 18.13 17.71 17.68 18.31 17.89 18.35 17.82 17.93 17.26 18.04 18.08 17.50 17.06 16.52 18.40 18.10 18.28 17.79 18.04

Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5 m (Outdoor unit to Branch box), 3 m (Branch box to Indoor unit) •Height difference: 0 m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. To fix your selection of models, select them according to “Model Selection” in the D&T manual.

Page 68: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

068

Simultaneous Multi Twin / Triple

Can support various installation scenes from office to commercial space by sameplace multi connection of up to 3 units.Indoor units distributed layout according to the shape and number of people and lighting conditions of the room even on wide floors and atypical floors. Ideal comfortable air flow distribution can be realized.

Simultanious Operation Multi type Indoor Unit Line up

Features

Installation according tofloor layout

Installation according tolighting conditions

Installation according tolayout and lighting conditions

Twin22x2

Cassette

Duct

Ceiling

Outdoorunit

18x2 24x2Triple18x3

Note: Combinations other than the above are not available.

Model : ROG36LATT [3phase]

ROG45LATT [3phase]

ROG54LATT [3phase]

RCG18LV×2 RCG22LV×2 RCG24LV×2 RCG18LV×3

RDG18LL×2

RYG18LV×2

RDG22LM×2

RYG22LV×2

RDG24LM×2

RYG24LV×2

RDG18LL×3

RYG18LV×3

ROG36LATT ROG45LATT ROG54LATT

Page 69: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

069

Features

Simultaneous controlMax 16 indoor units are simultaneously controlled with a wired remote controller.

SU MO TU WE TH FR SA

7

3 126 9 15 18 21

Transmission cable

Indoor unit 0(Master)Wired

Remort Controller

Remote controller cable

Bus wire

Indoor unit 1

Indoorunit 2

Indoorunit 14

Indoor unit 3

Indoor unit 15

Refrigerant pipeSet the indoor unit number using DIP switch on indoor unit circuit board.

Specifications

Dimensions (Unit : mm)

Net Dimension H x W x DWeight

Power Source

kg(lbs)mm

V/ Ø/Hz

Model No. Indoor unit Compact Cassette

230/1/50680/580/490/410

245x570x57015 (33)

CG-UFFD

230/1/50930/830/600/450

245x570x57016(35)

CG-UFFD

230/1/50930/830/600/450

245x570x57016(35)

CG-UFFD

Cooling Heating (@-10°C)

CoolingHeatingCoolingHeatingCoolingHeatingCoolingHeating

SEER SCOP

Sound Pressure (High)Sound Power (High)

Piping Connections (Small / Large) Max Pipe Length (Pre-Charge) Height Difference

Operation Range

Refrigerant Separation tube

Capacity

Pdesign

Power source

Annual Energy ConsumptionEnergy Efficiency Class

Net Dimension H x W x DWeight

V/ Ø/Hz

kW

kW

W/W

kWh/a

dB(A)

mmkg(lbs)

mm

m

°CDB

Model No. Outdoor unit

CoolingHeating

CoolingHeating

12.514.5

400/3/50--------

54-

1290x900x330104 (229)9.52/15.88

75(30)30

-15 to 46-15 to 24R410A

UTP-SX254A (Twin)

10.011.2

400/3/5010.010.06.004.00583

3499A+A+5167

1290x900x330104 (229)9.52/15.88

75(30)30

-15 to 46-15 to 24R410A

UTP-SX236A (Twin)

14.016.0

400/3/50--------

55-

1290x900x330104 (229)9.52/15.88

75(30)30

-15 to 46-15 to 24R410A

UTP-SX254A (Twin) / UTP-SX354A (Triple)

*Different type and capacity indoor units can not be connected .

Air Flow (High)

Cassette Grille

Cooling H/M/L/Q m3/h

Net Dimension H x W x DWeight

Power Source

kg(lbs)mm

V/ Ø/Hz

Model No. Indoor unit Duct

230/1/50940/880/820/750198 x 900 x 620

23 (51)

230/1/501100/910/750/580270 x 1135 x 700

38 (84)

Floor/Ceiling Universal

230/1/50780/700/560/500199 x 990 x 655

27 (60)

230/1/50980/820/680/540199 x 990 x 655

27 (60)

Air Flow (High) Cooling H/M/L/Q m3/h

1290

900

21

9

Ø28

(Cab

le po

rt)

Pipe port

87131 25 54

3 ( G

as v

alve

)54

0 (L

iqui

d va

lve)Ø28

(Cab

le po

rt)

3-way valve(Gas)

3-way valve(Liquid)

Terminal blocks

21 50

33031 12

Ø28

(Cable port)

21 5550

156

112

Ø28 (Cable port)

Pipe port

89

95 120

509516

7

21 67Ø28 (Cable port)Ø28 (Cable port)Pipe port

Front view Side view Rear view

A

188

265

302

400

51.5440

625

Bottom view

Detail A

1446

1654Pipe & cable port

RCG18LVLB RCG22LVLA RCG24LVLA

RDG18LLTB RDG22LMLA RDG24LMLA RYG18LVTB RYG22LVTA RYG24LVTA

ROG36LATT ROG45LATT ROG54LATT

Outdoor Unit : ROG36LATT / ROG45LATT / ROG54LATT

Page 70: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

070

Optional Parts List

Wired RemoteController

Simple RemoteController

Central RemoteController

IR Receiver Kitwith WirelessRemote Controller

RemoteSensor Unit

Auto LouverGrille Kit

Long Life Filter

Flange

Drain PumpUnit

Wide Panel

Panel Spacer

Fresh AirIntake Kit

Air OutletShutter Plate

Insulation forHigh Humidity

Half Concealed Kit

Remotecontrollerholder

Wall Mounted

Compact

Con

trol

lers

Oth

ers

Type

Slim Mediumstatic Compact LargeLarge

CassetteFloor/Ceiling

High staticFloor Ceiling

For 8 Room

For Cassette

Panel spacer

For Cassette

For Compact Cassette

For Cassette

For Compact Cassette

For Compact Cassette

Duct

For Duct

OPTIONAL PARTS FOR SPLIT & MULTI SPLIT

This kit is used to half conceal floor type indoor unit into the wall.

New amenity space can be offered byinstalling the Remote sensor.

RSG09/12LTCA

RSG30LFCA

RDC72LHTA/90LHTA

UTY-DMMXM

RSG18LFCA/24LFCC

UTY-DMMXM UTY-DMMXM

RCG07/09LVLA/

12/14/18LVLB

UTY-DMMXM

RDG07/09LLTA/12/14LLTB

UTD-GXSA

RDG18LLTB

UTY-LRHXM

UTD-GXSB

RDG22/24/36/45LMLA/

30/36LMLE

UTD-RF204 /SF045T

UTZ-PX1NBA

UTD-LF25NA

RDG45/54LHTA

UTD-LF60KA

RSG07/09/12/14LMCA

RSG07/09/12

LLCC

UTZ-RXLA

UTZ-KXGC

RCG30/36LRLE/

36/45/54LRLA

UTZ-KXGA

UTR-YDZB UTR-YDZC

UTZ-VXAA UTZ-VXGA

UTG-BGYA-W

UTG-AGYA-W

UTY-LRHXA2

UTY-LRHXM

RSG07/09/12/14LUCA

UTY-RVNXM

UTY-RSNXM

UTY-RNNXM

UTY-RVNXM

UTY-RSNXM

UTY-RNNXM

RCG22/24LVLA

UTY-RVNXM

UTY-RSNXM

UTY-RNNXM

RYG22LVTA/24LVTA

RYG14LVTA/18LVTB

UTY-DMMXM

UTY-RVNXM

UTY-RSNXM

UTY-RNNXM

RDG60LHTA

RGG09/12/14

LVCA

UTY-RVNXM

UTR-STA

UTY-DMMXM

UTY-RSNXM

UTY-RNNXM

RYG30/36LRTE/

36/45/54LRTA

UTD-RF204

UTR-DPB24T

UTY-RSNXM

UTY-RVNXM

UTY-RNNXM

UTY-XSZX

UTY-RSNXM

UTY-RVNXM

UTY-RNNXM

Page 71: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

071

Optional parts list (Communication devices)

MODBUS® Interface

WirelessLAN Interface

KNX® Interface

Communication Kit

ExternalConnect Kit

ExternalControl Set

Wall Mounted

Compact

Inte

rfac

e

Type

Slim Mediumstatic Compact LargeLarge

CassetteFloor/Ceiling

High staticFloor Ceiling

Single-phase 3-phase

Single Split Single Split SimultaneousMulti

For Compact Wall Mounted

For Indoor Unit*

For Indoor Unit*

For Outdoor Unit

For Outdoor Unit

For Outdoor Unit

DuctIndoor Unit Outdoor Unit

*Duct type is excluded.

For Indoor Unit (Duct type only) Use to connect with various peripheral devices and air conditioner PC board.

Refrigerant Piping Parts

UTP-SX236A / UTP-SX254ASeparation Tube

For 3-phase simultaneous multi

UTP-PY03A / UTP-PY02ABranch Box

For 8 Rooms Multi

UTP-SX354AFor 3-phase simultaneous multi For 8 Rooms Multi

UTP-SX248A

Liquid pipeuid pipe

Gas pipe

3 zones type 2 zones type

Connection Units

RSG09/12LTCA

RDC72LHTA/90LHTA

RSG18LFCA/24LFCC/30LFCA

UTY-TWBXF

UTY-XWZXZ5

RCG07/09LVLA

12/14/18LVLB

RDG07/09LLTA/

12/14/18LLTB

RDG22/24/36/45LMLA

30/36LMLE

RDG45/54/60

LHTA

RSG07/09/12/14LMCA

UTY-XCBXZ2

UTY-XWZX UTY-XWZX UTY-XWZX

UTY-XWZX

UTY-XWZX

RCG30/36LRLE

36/45/54LRLA

RSG07/09/12/14LUCA

RCG22/24LVLA

RYG14/22/24LVTA/

18LVTB

RGG09/12/14

LVCA

RYG30/36LRTE

36/45/54LRTA

ROG45LETL/54LETL

ROG45LBT8

ROG36/45/54/60LATT

ROA72/90LALT

ROG36/45/54

LATT

UTD-ECS5A UTD-ECS5A UTD-ECS5A

UTY-XWZXZ4

UTY-XWZXZ3

UTY-XWZXZ4

UTY-XWZXZ2

FJ-RC-MBS-1

FJ-RC-WIFI-1

FJ-RC-KNX-1i

Page 72: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

072

OPTIONAL PARTS FOR SPLIT & MULTI SPLIT

Wired Remote Controller : UTY-RVNXM

High performance and compact size•In addition to the individual control, various energy saving controls can be realized using only one remote controller.

Various energy saving functionAuto OFF Timer

• The indoor unit automatically is turned off when it reaches the preset operating time frame.

• The time frame of the "Auto off timer" can be flexibly scheduled.

• Can be set off time 30 to 240 minutes

Weekly Timer function• Can be set up to 8 times per day (On/Off, mode,Temp)

• 2 pattern settings(i.e. Summer/Winter setting) are available.

High visibility and Easy operation• Icon display of effectual functions.

• Main functions in large icons: "Mode", "Set Temp", and "Fan".

• Easy to operate by Control guide display.

• Simple operation with easy 4-way navigation pad.

Set Temperature Auto Return• The setting temperature automatically returns to the previously set

temperature.

• The time range in which the set temperature can be changed is 30 to 120 minutes.

Set Temperature Upper and Lower Limit Setting• The set temperature range can be set for each operation mode.

(Cooling / Heating / Auto)

Specifications

Max.controllable

16Indoor units

Model name

Power supply

Dimension (H × W × D) (mm)

Weight (g)

* DC12 V is supplied by indoor unit.

UTY-RVNXM

DC 12 V

120 × 120 × 21.3

220

Hi-grade individual control using various functions.

• 3.7-inch LCD backlight screen. • Supporting various Energy Saving functions with simple operation. • Multiple Language Support.

(English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish)

Individualcontrol

Thermosensor

Weeklytimer

Auto off timer

Setting temp.Cooling operation

24°C22°C

Set temperature change Auto return

AM11:40 PM1:40 AM11:40 PM1:40Time

Settable time range30 to 120 minutes

Setting temp.Heating operation

25°C23°C

Set temperature change Auto return

Time

Settable time range30 to 120 minutes

AM10:00 PM12:00 2:00 5:00 8:00 11:59

Weekly 1

Set T

emp.

(°C

)

Time

28

222324252627

26°C 26°C

28°C

27°CSetting menu in remote controller

26°C

25°C 25°C

On

Off

Weekly 2

Set T

emp.

(°C

)

Time

26

202122232425

24°C 24°C

22°C 22°C

Setting menu in remote controller

24°C

26°C 26°C

On

Off

AM10:00 PM12:00 2:00 5:00 8:00 11:59

Original temp.setting range

Lower limitsetting

During Cooling30°C

25°C

18°COriginal temp.setting range

Upper limitsetting

During Heating30°C

25°C

16°C

Icon display (weekly time)

Set temperature

Control guide display

Page 73: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

073

Auto Louver Grille Kit : UTD-GXSA-W / UTD-GXSB-W

Flexible Control• Operation with indoor unitAuto Louver can be operated by synchronizing remote controller of indoor unit.

• UP and Down auto swing• Auto airflow direction and auto swing• 4 steps selectable

• Auto-closing louverWhen operation of indoor unit is stopped, the louver will automatically close.

Dimensions

Simple flat Auto Louver will provide comfortairflow and harmonize with luxury interior.

Closed louver Opened louver

Controller Controller

Duct type

Wired Remote Wireles Remote

Auto Louver Grille

UTD-GXSA-W

W1 W2

683

883

645

845180 148 9 84

Unit: mm

Model Name H1 H2 D1 D2

UTD-GXSB-W

W1

W2

D2D1

H1 H2

Fitting Flame

Grille

Net

Gross

Cooling

Heating

kg(lb.)

% RH

°C (°F)

°C (°F)

Model name

Applicable Indoor Unit

Power Supply

Fixing of Auto Louver Grille

Extension Square Duct Limit

Color

Louver Motor

Accessories

Operation range

Weight

RDG07/09LLTA RDG12/14LLTB

180x683x(84+9)

[7-3/32x26-7/8x(3-5/16+11/32)]

2.0 (4.4)

3.0 (6.7)

UTD-GXSA-W

180x883x(84+9)

[7-3/32x34-3/4x(3-5/16+11/32)]

2.5 (5.6)

3.5 (7.8)

White

Stepping Motor

Fitting Flame, etc.

18 to 32 (64 to 90)

80% or less

16 to 30 (60 to 88)

Connecting with Control box of indoor unit

Screw xing to Flange or Square Duct

1.0m (Max. duct length between indoor unit and Grille)

RDG18LLTB

UTD-GXSB-W

mm(inch)

Net Dimension(H x W x D)

Specifications

Page 74: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

074

OPTIONAL PARTS FOR SPLIT & MULTI SPLIT

Indoor unit

Wireless LAN Interface : FJ-RC-WIFI-1

• It is the most advanced solution to remotely manage an Air Conditioning system using all sort of mobile devices such as Smartphones, Tablets and PC

• No separate external power supply required• Can be used for single indoor units and group controlled (up to 16) indoor units

N E W

Smartphone

Tablet

PCRouter(Field supplied)

phone

et

Internet

R(

(Application screen image)

Basic control• Turning the units on and off

• Mode control (Heat, Cool, Dry, Auto, Fan)

• Fan speed setting

• Louver position (Airflow direction setting)

• Room temperature display

• Set temperature control

• Multi Language

• One Scene and Timer

Advanced control (Optional functions)• Climate working modes (ECO, Comfort, Powerful) (future release)

• Schedulable functionalities (ON/OFF, Modes, Set point temperature, Fan Speed, Louver position)

• Set temperature limitation (future release)

• Multiple Scenes & Timers and Calendar function

Notifications and history• Alerts e-mail notification (future release)

• Air conditioning malfunction alerts

• Connectivity monitoring and alerts

• History (future release)

Wireless LANInterface

SpecificationsModel name

Dimensions (H x W x D) (mm)

Weight (g)

FJ-RC-WIFI-1

70×108×28

80

Page 75: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

075

Specifications

MODBUS® Interface : FJ-RC-MBS-1

The MODBUS Interface allows a complete integration of air conditioners into MODBUS Networks.

• Simple installation due to small and compact size.• No separate external power supply required.• The Modbus Interface permits central monitoring and control of air conditioners from BMS.

Model name

Weight (g)

Dimensions (H x W x D) (mm)

FJ-RC-MBS-1

93×53×58

85

FJ-RC-KNX-1i

70×70×28

70

Max. 63MODBUS Interface

BMS/Central Controller

KNX® Interface : FJ-RC-KNX-1i

The KNX Interface allows a complete integration of air conditioners with KNX Network systems.

• Simple installation due to small and compact size.• No separate external power supply required (just KNX bus power).• Can be used for single indoor units and group controlled (up to 16) indoor units.

MODBUS Network

KNX Network

KNXInterface

Lighting facilities

Security system

Automatic fire alarm interface

Windows bind

The MODBUS Interface can be used withor without Wired Remote Controller.

Wired Remote Controller

Split Indoor unit

VRF Indoor unit

VRF Indoor unit

Split Indoor unit

VRF Indoor unit

The KNX Interface can be used with or without Wired Remote Controller.

or

Wired Remote Controller

Home Controller

N E W

N E W

Page 76: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

076

OPTIONAL PARTS FOR SPLIT & MULTI SPLIT

Communication KitUTY-TWBXF / UTY-XCBXZ2

KNX® InterfaceFJ-RC-WIFI-1

Wireless LAN Interface MODBUS® InterfaceN E W FJ-RC-KNX-1iN E W FJ-RC-MBS-1N E W

Communication devices

UTY-RNNXMWired Remote Controller

UTY-RVNXMWired Remote Controller Simple Remote Controller

UTY-RSNXM UTY-DMMXMFor 8 Rooms Multi

Central Remote Controller

ControllersFor Individual & Centralized Control

For Compact Wall Mounted type

Interface Communication Kit

External Control SetFor Indoor Unit

UTD-ECS5AUTY-XWZX UTY-XWZXZ5

External Connect KitFor Outdoor unit

UTY-XWZXZ4UTY-XWZXZ3UTY-XWZXZ2

External Connect KitFor Indoor Unit

External Connect Kit / External Control set

Input

* 1 : Duct type does not have this function.* 2 : Cassette and Ceiling type does not have this function.

Output

Function list

UTY-XWZXZ2—●●——●●————

For Outdoor unit

UTY-XWZXZ3—●●●●●●————

UTY-XWZXZ4——————————●

UTD-ECS5A●————●

●*1

● ●*2

●*2

For Indoor unit

UTY-XWZXZ5●————●●————

UTY-XWZX●————●—————

ControlPeak cutLow noisePriorityEmergency stopOperation statusError statusFresh air controlAuxiliary heaterPreparationBase heater

Page 77: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

077

For Compact Cassette type

For Compact Cassette type

Fresh Air Intake KitUTZ-VXAA

Panel Spacer Fresh Air Intake Kit

For Cassette type

For Floor type

Shuts the air outlet when only using as 3 blow out.

Air Outlet Shutter PlateUTR-YDZB

Shuts the air outlet when only using as 3 blow out.

Air Outlet Shutter PlateUTR-YDZC

UTZ-VXGA

IR Receiver KitUTY-LRHXA2

This kit is used to half conceal floor type indoor unitinto the wall.

UTR-STAHalf Concealed Kit

Indoor unit950

Panel 600

600(mm)

Panel spacer

242 mm

UTG-AGYA-WWide Panel

UTG-BGYA-W UTZ-KXGA / UTZ-KXGCInsulation Kit For High Humidity

For Compact Cassette type / Cassette type

Insulation Kit

For Wall Mounted type For Ceiling type

Drain Pump UnitUTR-DPB24T

Remote Controller Holder Service Monitoring ToolUTZ-RXLAFor ASYG07 / 09 / 12LLCC

UTY-ASSX

Cassette Grille

For Compact Cassette type

CG-UFFD Cassette GrilleCG-GFA

Service & Maintenance

N E W

For Duct type

IR Receiver KitUTY-LRHXM

Auto Louver Grille KitUTD-GXSA-WFor 07 / 09 / 12 / 14 type

UTD-GXSB-WFor 18 type

Long-Life Filter

UTZ-PX1NBA

UTD-LF60KAUTD-LF25NA

UTD-LF60KA UTD-LF25NA

Remote Sensor UnitUTY-XSZXNew amenity space can be offered by installing the Remote sensor.

Drain Pump UnitFlangeUTD-RF204 (Round)UTD-SF045T (Square)

(Round) (Square)

+

For Medium Static Pressure Duct

Others

Page 78: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

078

Title

Comfortable Function Convenient Function

Double swing automaticComplex swing action of flaps enables automatically to swing both horizontal and vertical directions.

Up / down swing flapsThe up / down flaps automatically swing up and down.

Auto restartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.

Auto-changeoverThe unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.

10°C HEAT operationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

Automatic air flow adjustmentThe micro-computer automatically adjusts the air flow effectively to follow the changes of room temperature.

Sleep timerThe micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep.

Program timerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON.

Weekly timerDifferent ON-OFF times can be set for each day.

Weekly + setback timerWeekly + Setback timer can set temperature for two times spans and for each day of the week.

Filter signIndicates the filter cleaning period by lamp.

Economy modeLimits the maximum operation current, and performs operation with the power consumption suppressed.

Powerful modeOperation at maximum air flow and compressor speed, and quickly makes the room comfortable.

Low Noise ModeSound noise level of outdoor unit can be selected.

Connectable fresh air duct

Fresh air intakeFresh air can be taken in by a fan which can be connected using external control unit.

Connectable distributing duct

Clean Function

Apple-catechin filterThe Apple-catechin filter uses static electricity to clean fine particles and dust in the air.

Washable panel

The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

Ion deodorization filter

i-PAM control models

V-PAM control models

Human sensorHuman sensor catches movements of people in a room.

POWERFULPOWERFULPOWERFUL

FEATURE EXPLANATION

Page 79: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

079

Feature Summary

Com

fort

able

func

tion

Con

veni

ent f

unct

ion

Clea

n fu

nctio

n

Up / down swing flaps

Wall Mounted

Floor

Compact Cassette / Cassette

Floor/Ceiling

Ceiling

Slim DuctMedium Static Pressure Duct

High Static Pressure Duct

Double swing automatic

Automatic air flow adjustment

Auto restart

Auto-changeover

10°C heat operation

Connectable distributing duct

Connectable fresh air duct

Fresh air intake

Economy mode

Sleep timer

Program timer

Weekly timer

Weekly + setback timer

Filter sign

Ion deodorization filter

Apple-catechin filter

Washable panel

RSG09/12LTCA

RSG07/09/12/14LMCA

RSG07/09/12/14LUCA

RSG07/09/12LLCC

RSG18/30LFCA, RSG24LFCC

RSG07/09/12LJCA

RGG09/12/14LVCA

RCG12/14/18LVLB, RCG24LVLA

RCG30/36LRLE, RCG36/45/54LRLA

RYG18LVTB, RYG24LVTA

RYG30/36LRTE, RYG36/45/54LRTA

RDG12/14/18LLTB

RDG24/36/45LMLA, RDG30/36LMLE

RDG45/54/60LHTA

RDC72/90LHTA

: Optional function

Human sensor

Powerful modePOWERFULPOWERFULPOWERFUL

(60)

(60)

(60)

(45/54)(36LRTA)

(45/54)(36LRLA)

(45)(36LMLA)

Low Noise mode

Page 80: AIR CONDITIONERS LINEUP€¦ · The heat load varies greatly depending on the time and season. However, the operation ratio EER or COP up to now has been calculated based on the rated

Notice for specificationsI.U.=Indoor Unit O.U.=Outdoor Unit Qu=Quiet * =Not decided yet• Specifications and design subject to change without notice for further improvement. Please check with your dealer.• Cooling/Heating capacities are based on the following conditions.

Cooling Indoor temp.Outdoor temp.

: 27˚C DB/19˚C WB: 35˚C DB/24˚C WB Heating : 20˚C DB/15˚C WB

: 7˚C DB/6˚C WBIndoor temp.Outdoor temp.

• The colors may be different from the actual colors because this catalog is printed matter.

3EJ009-1401E