air comprime (ac) lecture1 pg 2-26.pdf
TRANSCRIPT
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
1/25
ecture 1-Solid-liquid-vapour
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
2/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
3/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
4/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
5/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
6/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
7/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
8/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
9/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
10/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
11/25
Volumetric flowrate
• The volumetric flow rate of a system is a measure of the volume of fluid
flowing per unit of time.
• It may be calculated as the product of the cross-sectional area of the flow
and the average flow velocity. The SI unit for volume rate of flow is m3/s.
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
12/25
Compression et détente de AC
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
13/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
14/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
15/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
16/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
17/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
18/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
19/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
20/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
21/25
Types of Compressor
There are two generic principles for the compression of air (or gas):
positive displacement compression and dynamic compression.
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
22/25
Positive displacement
In positive displacement compression, the air is drawn into one or
more compression chambers, which are then closed from the inlet.
Gradually the volume of each chamber decreases and the air is
compressed internally. When the pressure has reached the designed
build-in pressure ratio, a port or valve is opened and the air is
discharged into the outlet system due to continued reduction of the
compression chamber’s volume.
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
23/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
24/25
-
8/17/2019 Air comprime (AC) lecture1 pg 2-26.pdf
25/25
Etude de cas: Considérations énergétiques et pratiques
Calculer le travail qu’il faudra fournir pour comprimer en mode
isothermique et adiabatique, 1 kg d’air a une pression de 8 bar.
L’aspiration se fait a 1 bar et 150C.