agilent technologies oscilloscopes oscilloscopes - industry’s largest portfolio economy 20mhz –...
TRANSCRIPT
Agilent Technologies Oscilloscopes
March 2011
Agilent Oscilloscopes - Industry’s Largest Portfolio
Economy 20MHz – 200MHz
U1600A Series
Handheld
U2700 Series
USB
InfiniiVision 70MHz – 1GHz
7000 Series
3000X Series 6000/6000L Series
Infiniium 600MHz – 80GHz
DCA-X Series
90000 Series
9000 Series
90000 X-Series
September 1, 2010
Fastest Growing Scope Company
2000X Series
Agilent 100 MHz / 200 MHz HH Scopes
At A Glance
Month ##, 200X
Group/Presentation Title
Model U1610A U1620A
Bandwidth 100 MHz 200 MHz
Channel 2 2
Display 5.7” VGA TFT LCD color display
(640 x 480 pixels)
Sampling rate 1 GSa/s (500 MSa/s for each
channel)
2 GSa/s (1 GSa/s for each
channel)
Recording length (Memory) 120 kpts / channel interleave
(60 kpts for non-interleave
channel)
2 Mpts / channel interleave (1
Mpts for non-interleave
channel)
Meter Function
Meter resolution 10,000 counts
Meter measurements DCV, ACV, ACV+DCV, Diode, Continuity, Resistance,
Capacitance, Temperature, Frequency
User-ability
Local Language Graphic
User Interface (GUI)
10 selectable languages:
English, Francais, Deutsch, Italiano, Espanol, Portugues,
Simplified Chinese, Traditional Chinese, Japanese, Korean
View mode Indoor mode, Outdoor mode, Night vision
Safety
Channel-to-channel isolation
Safety rating CAT III 600 V
Ingress Protection IP 41
World’s 1st HH Scope With VGA TFT LCD Display
Month ##, 200X
Group/Presentation Title
5.7 inch VGA TFT LCD
What it really means How it benefits user?
VGA 4x more resolution 4x more details than QVGA
TFT LCD A variant of liquid crystal display (LCD) that
uses thin-film transistor (TFT) technology to
improve image quality
Better image addressability
and contrast to view
waveform clearly
Read Under All Lightning Conditions
Month ##, 200X
Group/Presentation Title
Indoor mode Outdoor mode Night vision mode
See Signal Details Over Long Period Of Time
Month ##, 200X
Group/Presentation Title Page 6
Chasing down a problem
View both problem effect
and problem cause in a single
acquisition
Characterizing the signal
Maintain high signal
resolution when zooming in,
even after acquiring long
periods of time
2 Mpts memory - for validation and debug:
InfiniiVision: 70 MHz-1GHz
September 1, 2010
InfiniiVision 70MHz – 1GHz
7000 Series
3000X Series 6000/6000L Series
2000X Series
Agilent InfiniiVision Series
6000L Series
2000 X-Series
Common Features:
• MSO Models and Upgrades
• Fast Waveform Update Rates
• Deep & Responsive
MegaZoom Memory
• High Resolution Display
Intensity Gradation
• Hardware-based Serial
Decode and Triggering
• Hardware-based Mask
Testing
• Segmented Memory
• Search and Navigation
3000 X-Series
7000B Series
6000A Series
InfiniiVision 2000/3000 X-Series
January 1, 2011
Page 8
Engineered for Best Signal Visibility
Model Unique Positioning Bandwidth Sample*
Rate
Memory*
(max)
Update Rate
(max)
Scope
Channels
Logic
Channels
2000 X-Series Lowest Price, WaveGen 70MHz to 200MHz 2 GSa/s 100 kpts 50k /sec 2 or 4 8 optional
3000 X-Series Fastest Update Rate,
WaveGen
100MHz to
500MHz 4 GSa/s 4 Mpts 1M /sec 2 or 4 16 optional
6000A Series Battery Option 100MHz to 1GHz 4 GSa/s 8 Mpts 100k /sec 2 or 4 16 optional
6000L Series 1U High 100MHz to 1 GHz 4 GSa/s 8 Mpts 100k /sec 2 or 4 16 optional
7000B Series Highest Perf, Largest Display 100MHz to 1GHz 4 GSa/s 8 Mpts 100k /sec 2 or 4 16 optional
* Half channel interleaved mode
Možnost vidět to,
co na jiných osciloskopech zůstává skryto
8.5” WVGA obrazovka nabízí 2x větší zobrazovací plochu a 5x tolik
pixelů
Zpracování 1.000.000 průběhů / s
Paměť MegaZoom 4. generace
Agilent
custom
ASIC
technology
designed for
market
leading
value.
Ne pouze osciloskop, ale 4 přístroje v jednom!
Osciloskop s nejrychlejším zpracováním signálu na trhu (1.000.000
stop / s)
Logický analyzátor - 16 kanálů
Funkční a arbitrary generátor 20 MHz (DDS, 10 bit, 100 Msa/s, 5 kpts)
Protokolový analyzátor
Protokolový analyzátor
Hardwarově akcelerované dekódování
umožňuje protokolovou analýzu skutečně
v reálném čase, korelovaně s časovým
průběhem signálu, bez zpomalení činnosti
osciloskopu. Možnost dekódování více
sběrnic současně.
• I2C/SPI
• CAN/LIN
• FlexRay
• RS232/UART
• I2S
• MIL-STD 1553/ARINC 429
FlexRay trigger and decode
FlexRay eye diagram mask test
DSO InfiniiVisionX další měřicí aplikace
• Maskové Testy až 280.000 testů / s
• Segmentovaná Paměť až 1.000
segmentů
• Advanced Math přídavné matematické
funkce, filtry, trendy
• HDTV Video spouštění na high-
definition video signály
• Analýza spínaných zdrojů
• Digitální Voltmetr 3-místný digitální
voltmetr používající osciloskopické
vstupy
Infiniium: 600MHz - 80GHz
DCA-X Series Up to 80 GHz
90000 Series 2.5 – 13 GHz
9000 Series 600 MHz – 4 GHz
90000 X-Series 16 – 32 GHz
September 1, 2010
Infiniium 9000 Series
Engineered for broadest measurement capability
Embedded System Design
Signal Integrity
Compliance Verification
Key Applications
September 1, 2010
Model Analog
Bandwidth
Max Sample
Rate *)
Standard
Memory *)
Analog
Channels
Digital
Channels
DSO9064A 600 MHz 5 Gsa/s 20 Mpts 4
MSO9064A 5 Gsa/s 20 Mpts 4 16
DSO9104A 1 GHz 10 Gsa/s 20 Mpts 4
MSO9104A 10 Gsa/s 20 Mpts 4 16
DSO9254A 2.5 GHz 10 Gsa/s 20 Mpts 4
MSO9254A 10 Gsa/s 20 Mpts 4 16
DSO9404A 4 GHz 10 Gsa/s 20 Mpts 4
MSO9404A 10 Gsa/s 20 Mpts 4 16
*) Sample Rate and Memory double in 2ch Mode
Why buy the 9000 Series?
The best 3 in 1 instrument – debug your design with a single tool
• Industry-leading scope performance
• High-performance logic analysis
• Powerful, integrated protocol analysis
Broadest application selection (over 30) gives you an “Everything Analyzer”
• Bus compliance, verification, and analysis
• InfiniiScan software triggers
• User-defined applications and functions
• Jitter analysis, equalization, de-embedding, and much more
Sized to fit your bench and budget
• 15 inch display
• Only 9 inches deep and only 26 pounds
• Upgradeable memory, digital channels, bandwidth and apps
September 1, 2010
Why buy the 90000 Series?
Superior signal integrity – shows the signal, not the scope
• Lowest noise floor
• Lowest trigger jitter
• Agilent RF design expertise
Innovative probing – for your design
• Industry-leading signal integrity – all the way to the probe tip
• Flexible and comprehensive connection options
Designed for your application – today and tomorrow
• Fully upgradeable, including bandwidth
• Dozens of application packages expand your analysis
September 1, 2010
Infiniium 90000 X-Series Oscilloscopes
Engineered for true analog bandwidth that delivers
The highest real-time scope measurement
accuracy
Complete 30 GHz oscilloscope probing
system
The industry’s most comprehensive
application-specific measurement software
6 New Scope Models DSO/DSA91604A DSO/DSA92004A DSO/DSA92504A DSO/DSA92804A DSO/DSA93204A
Analog Bandwidth (2 ch) 16 GHz 20 GHz 25 GHz 28 GHz 32 GHz Max Sample Rate (2 ch /
4 ch) 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s Std Memory *) 20M 20M 20M 20M 20M Max Memory 2 Gpts 2 Gpts 2 Gpts 2 Gpts 2 Gpts
Noise @ 50mV/div 1.34 mV 1.53 mV 1.77 mV 1.89 mV 2.08 mV Jitter Measurement Floor 150 fs rms 150 fs rms 150 fs rms 150 fs rms 150 fs rms
Bandwidth upgradeable for investment protection
*) DSA model: 50M Std Memory, EZJIT Plus, SDA
Why buy the 90000 X-Series? The industry’s highest real-time scope measurement accuracy • Highest true analog bandwidth (32 GHz)
• Lowest oscilloscope noise floor (2.04 mV at 50 mV/div, 32 GHz)
• Lowest jitter measurement floor (150 fs)
Industry’s first 30 GHz oscilloscope probing system
• InfiniiMax III high-frequency probes with automatic AC calibration (PrecisionProbe)
• Fully-integrated probe amplifier s-parameter correction
• The industry’s first bandwidth-upgradable probe amplifier
Industry’s most comprehensive application-specific measurement software
• Broadest range of jitter, triggering, analysis and display tools
• Pre-built compliance testing software based on the expertise of our engineers on the standards committees
• Support for emerging technologies including FibreChannel, SAS 12G or MIPI-MPhy
September 1, 2010
True Analog Bandwidth that Delivers
The Industry’s Highest Measurement Accuracy
The Final Result: 1. Over 25% larger eye height and
width measurements
2. Lower total jitter measurements
3. More detail is captured in the
eye, that is buried in other
oscilloscope noise floor
20 GHz versus 20 GHz at 10.4 Gbps j-BERT PRBS^7
signal, lowest setting of ISI added via the jBert
0
5
10
15
20
25
0 50 100 150 200 250 300 3500 50 100 150 200 250 300 350
Ft (GHz)
BV
ce
o(V
olt
s)
25
20
15
10
5
0
UM
NGST
Agilent
Agilent & SFU
Research
InP
DHBT
InP SHBT
& GaAs
HRL
TRW
NTT
Si &
SiGe
HB2A
IBM HP8HitachiIBM •
IBM HP7
GCS
Agilent’s Proprietary
InP HBT Process
Enabled by Unique
HFTC GaAsSb Epi
HB2BAgilent
St-9MW
Jazz
0
5
10
15
20
25
0 50 100 150 200 250 300 3500 50 100 150 200 250 300 350
Ft (GHz)
BV
ce
o(V
olt
s)
25
20
15
10
5
0
UM
NGST
Agilent
Agilent & SFU
Research
InP
DHBT
InP SHBT
& GaAs
HRL
TRW
NTT
Si &
SiGe
HB2A
IBM HP8HitachiIBM •
IBM HP7
GCS
Agilent’s Proprietary
InP HBT Process
Enabled by Unique
HFTC GaAsSb Epi
HB2BAgilent
St-9MW
Jazz
Innovative Chipset Designed in Agilent’s Proprietary High-
speed High-Voltage InP HBT Process
Low noise and high measurement accuracy
2X usable voltage
Superior pulse distortion control, enhanced fidelity
Significant margin in speed and linearity
Lower noise operation in high frequency architectures
High Ft, BS vias, high resistivity substrates enable flatter response to higher frequencies
Clear path to 300+ GHz Ft
Tektronix
70000B/C
Agilent
Next Gen
20
Agilent Confidential
Cutoff Frequency
Using Frequency Interleaving to Achieve 30 GHz
Attenuator
Trip
lexer
DS
P C
hannel C
om
bin
er
Preamplifier
ADC
ADC
Down -
converter Preamplifier
ADC
ADC
High frequency components from 16 – 30 GHz
Notice, that one
down-converter is
now in use and a
triplexer.
Requires three
pre-amps, which
is why it is only
available on ONE
channel
Low frequency components from 0 - 16 GHz
Using Frequency Interleaving to Achieve 45 GHz
Attenuator
Trip
lexer
Down -
converter Preamplifier
ADC
ADC
High frequency components from 31 – 45 GHz
DS
P C
hannel C
om
bin
er
Preamplifier
ADC
ADC
Down -
converter Preamplifier
ADC
ADC
High frequency components from 16 – 30 GHz
Notice, that two
down-converters
are now in use
and a triplexer.
Requires three
pre-amps, which
is why it is only
available on ONE
channel
Low frequency components from 0 - 16 GHz
The highest measurement accuracy : industry’s lowest noise floor
Engineered for true analog bandwidth that delivers
At 20 GHz, the 90000 X-
Series has less than ½ the
noise floor of either
Tektronix or LeCroy
At 32 GHz, the 90000 X-
Series has less noise than
Tektronix or LeCroy have
at 16 GHz!
You get the additional nine
GHz of analog bandwidth
with no noise penalty
compared to other
oscilloscope vendors.
Frequency
Interleaving
DSP
Boosting
Infiniium 86100D DCA-X System
The world’s most accurate oscilloscope
• Modular platform providing four instruments in one:
– Digital Communication Analyzer: de-facto industry standard
– Wideband oscilloscope: DC to > 93 GHz coverage
– Time Domain Reflectometer
– Jitter Analyzer
• Storage & Communication R&D
• Storage & Communication MFG
• Computers & High-Speed
Consumer Electronics R&D
Optical &
Electrical
Applications
Oscilloscopes Portfolio Overview
Agilent Confidential
October 9 2009 September 1, 2010
Why buy the DCA-X Series?
Deep insights – helps R&D to address root causes of issues
• Accurate knowledge accelerates design cycles
• Faster time-to-market = competitive advantage, lower investment cost
Great modularity – allows MFG to test large variety of products
• Re-use of test equipment improves utilization rates, reduces CAPEX
• > 12 years (4 generations) backward compatibility protects past investments
Superior usability – pleases novice and power users
• Occasional users can complete tasks with less risk of accidental errors
• Power users get throughput that save$ time when testing larger quantities
Oscilloscopes Portfolio Overview
Agilent Confidential
October 9 2009 September 1, 2010